Você está na página 1de 6

SITE / ROADWAY

EKG TYPE 5
SERIES

EKG TYPE 5
CONVENTIONAL SHOEBOX LUMINAIRES

EKG: 70 - 400 WATT


TYPE 5: 150 - 400 WATT
Conventional Shoeboxes

The Shoebox
Kim Lighting introduced the
Table of Contents Conventional Shoebox, in the
form of the EKG, nearly three
EKG Ordering Information 2-3 decades ago. These innocuous
products revolutionized
Type 5 Ordering Information 5
site/area luminaire design.
The simple Shoebox housing
encapsulates the modern
principles of optical distribution
design, cutoff control, and
clean aesthetics.
Since the introduction of the
EKG and Type 5 luminaires,
Kim has evolved a wide range
of products that take these
principles further than ever.
From the trend-setting
Archetype to the most recent
Matrix series, the EKG and
Type 5 stand as the roots upon
which greater designs have
grown.
Offered here in the twilight of
their lifecycles, the EKG and
SITE / AREA
Type 5 remain iconic
PARKING STRUCTURE representations of the
ROADWAY Conventional Shoebox genre
ARCHITECTURAL FLOOD that Kim pioneered. The fact
ACCENT
LANDSCAPE
they remain in demand today is
a testimony to their enduring
MAILING ADDRESS:
P.O. BOX 60080 quality.
CITY OF INDUSTRY, CA
91716-0080

BUSINESS ADDRESS:
16555 EAST GALE AVENUE
CITY OF INDUSTRY, CA 91745
U.S. A.
PHONE 626 / 968 - 5666
FAX 626 / 369 - 2695
ENTIRE CONTENTS
COPYRIGHT 1999 KIM LIGHTING, INC.
ALL RIGHTS RESERVED
REPRODUCTION IN WHOLE OR IN PART
WITHOUT PERMISSION IS STRICTLY PROHIBITED.

www.kimlighting.com

RvA Council
for Accreditation
Audited to ISO9001 Standards

Printed in U.S.A.
5502399214
Version 8/99
EKG

KIM LIGHTING 1
Ordering Information
EKG
Mogul Base
EKG Models 70 to 400 Watt

Mounting Fixture Electrical Module Finish Options Pole


6 Optional Houseside Cat. No.: HS For highly reduced light on houseside. Two shielding
Shield: components permanently installed at the Kim factory. One
Ordering Example: 2B / EKG501 / 250HPS277 / BL-P / A-25 / PSA25-5188B / BL-P component reduces light directly from the lamp; the other
component reduces reflected light. Recommended for use
For Standard Fixture 1 2 3 4 5-7 8 Houseside with clear lamps only.
and Pole See separate Kim Pole Catalog. Shield
Omit for 1W Wall Mount.

1 Mounting: 7 Optional Photocell Cat. No.: A-25 A fully gasketed receptacle installed above the electrical compartment for NEMA base
Wall Receptacle: photocell (by others). For all multiple-fixture pole mountings with two or three fixtures, one
Plan View: Mount fixture has a receptacle to operate the others. Four fixtures (250 watt or less) also require
one fixture with a receptacle. Four fixtures (400 watt) require two fixtures with
receptacles.
Cat. No.: 1A 2B 2L 3T 4C 1W
s s
Receptacle Mounting Configuration 1A or 1W 2B
2 Fixture: s s s s s s
Fixture
with photocell
s
Cat. No. designates EKG receptacle s slave unit(s). 2L 3T 4C 4C
fixture with standard mounting
Allowable Wattage per fixture: 150-400W 150-250W 400W
arm.
Cat. No.: EKG401 EKG501
EKG402 8 Poles: See Kim Pole Catalog for a complete selection of square and round poles in aluminum or steel.

3 Electrical Module: EKG401 fixture only:


HPS = High Pressure Sodium 70HPS120 100HPS120 150HPS120 200HPS120 250HPS120 175MH120 250MH120
70HPS208 100HPS208 150HPS208 200HPS208 250HPS208 175MH208 250MH208
MH = Metal Halide 70HPS240 100HPS240 150HPS240 200HPS240 250HPS240 175MH240 250MH240
70HPS277 100HPS277 150HPS277 200HPS277 250HPS277 175MH277 250MH277
SMH = Metal Halide with 70HPS347 100HPS347 150HPS347 200HPS347 250HPS347 175MH347 250MH347
reduced outer jacket 70HPS480 100HPS480 150HPS480 200HPS480 250HPS480 175MH480 250MH480
EKG402 fixture only:
Lamp Lamp Line 400HPS120 400SMH120
Watts Type Volts 400HPS208 400SMH208
400 HPS 277 400HPS240 400SMH240
400HPS277 400SMH277
400HPS347 400SMH347
400HPS480 400SMH480
EKG501 fixture only:
150HPS120 200HPS120 250HPS120 400HPS120 175MH120 250MH120 400MH120
150HPS208 200HPS208 250HPS208 400HPS208 175MH208 250MH208 400MH208
150HPS240 200HPS240 250HPS240 400HPS240 175MH240 250MH240 400MH240
150HPS277 200HPS277 250HPS277 400HPS277 175MH277 250MH277 400MH277
150HPS347 200HPS347 250HPS347 400HPS347 175MH347 250MH347 400MH347
150HPS480 200HPS480 250HPS480 400HPS480 175MH480 250MH480 400MH480

4 Finish: Standard Finishes


Standard Finish is Super TGIC Color: Black Dark Bronze Light Gray White *Custom Colors
powder coat paint over Cat. No.: BL-P DB-P LG-P WH-P CC-P
chromate conversion coating. *Consult representative for custom colors.
Optional Architectural Class 1
Optional Anodized Finish (Available at extra cost.)
anodized finish is available at
Color: Dark Bronze Anodize
extra cost.
Cat. No.: DB-A

5 Optional Polycarbonate Cat. No.: LS Optional Polycarbonate Shield replaces standard


Shield: tempered glass lens. One piece vacuum formed clear
polycarbonate. Polycarbonate Shield is semi-pyramidical
in shape for high thermal resistance, impact resistance
and light transmission. 250 watt maximum.
NOTE: May be used with 400HPS in outdoor locations
where ambient air temperature during fixture operation will
Side view Front view not exceed 85F. CAUTION: Use only when vandalism is
Polycarbonate anticipated to be high. Useful life is limited by discoloration
Shield caused by UV from sunlight and metal halide lamps.

2 KIM LIGHTING KIM LIGHTING 3


TYPE 5

KIM LIGHTING 4
Ordering Information Post Top Mount Arm Mount

Type 5
Mogul Base
Type 5 Models 150 to 400 Watt

Mounting* Fixture Finish Options Pole

Ordering Example: 2B / 5X-107 / BL-P / A-25 / PSA25-5188B / BL-P


For Standard Fixture 1 2 3 4-5 6
and Pole *Omit for Post Top Mount See separate Kim Pole Catalog.

1 Mounting: Plan View and Cat. No. for


2B 4C
Side Arm Mounting only:

HOME
2 Fixture:
Cat. No. designates Type 5 fixture with square light pattern, selected mounting option, electrical module, and lamp.
NOTE: 5SQ Series fixtures are available with an asymmetric light pattern. To order, replace SQ in the catalog number with AT. Example: 5AT-105.
Cat. No. Cat. No. Cat. No. Cat. No.
Post Top Arm Fixture Lamp Line Post Top Arm Fixture Lamp Line
Mount Mount Size (by others) Volts Mount Mount Size (by others) Volts
5SQ-165 5X-165 120 5SQ-150 5X-150 120
5SQ-166 5X-166 150 Watt 208 5SQ-151 5X-151 208
175 Watt
5SQ-167 5X-167 High 240 5SQ-152 5X-152 240
24" square 24" square Metal
5SQ-168 5X-168 Pressure 277 5SQ-153 5X-153 277
Halide
5SQ-175 5X-175 Sodium 347 5SQ-174 5X-174 347
5SQ-169 5X-169 480 5SQ-154 5X-154 480
5SQ-135 5X-135 120 5SQ-130 5X-130 120
5SQ-136 5X-136 250 Watt 208 5SQ-131 5X-131 208
250 Watt
5SQ-137 5X-137 High 240 5SQ-132 5X-132 240
24" square 24" square Metal
5SQ-138 5X-138 Pressure 277 5SQ-133 5X-133 277
Halide
5SQ-173 5X-173 Sodium 347 5SQ-172 5X-172 347
5SQ-139 5X-139 480 5SQ-134 5X-134 480
5SQ-111 5X-111 120 5SQ-105 5X-105 120
5SQ-113 5X-113 400 Watt 208 5SQ-106 5X-106 208
400 Watt
5SQ-115 5X-115 High 240 5SQ-107 5X-107 240
24" square 24" square Metal
5SQ-117 5X-117 Pressure 277 5SQ-108 5X-108 277
Halide
5SQ-171 5X-171 Sodium 347 5SQ-170 5X-170 347
5SQ-119 5X-119 480 5SQ-109 5X-109 480

2a Optional Tenon Cat. No.: T For mounting poles with 2" pipe-size tenon (2C" O.D. x 4K" minimum length.)
Mount: Add T to Catalog No. Example: 5SQ-115T

3 Finish: Standard Finishes


Standard Finish is Super TGIC Color: Black Dark Bronze Light Gray White *Custom Colors
powder coat paint over Cat. No.: BL-P DB-P LG-P WH-P CC-P
chromate conversion coating. *Consult representative for custom colors.
Optional Architectural Class
Optional Anodized Finish (Available at extra cost.)
1 anodized finish is available
Color: Dark Bronze Anodize NOTE: For all fixtures, lens frame assembly is finished in
at extra cost. Cat. No.: DB-A Light Gray (LG-P).

4 Optional Cat. No.: LS-5 One piece, vacuum formed shield mounted in a one piece high temperature
Polycarbonate Shield: gasket in place of standard glass lens. Not available for 400 watt fixtures.
CAUTION: Use only when vandalism is anticipated to be high. Useful life is
Polycarbonate Shield limited due to yellowing caused by UV from sunlight and Metal Halide lamps.

5 Optional Photocell Cat. No.: A-25 Integrally mounted to accept NEMA base photocell (by others). For all pole
Receptacle: mountings with two fixtures, one fixture has a receptacle to operate the other.
Receptacle Four fixtures (250 watt or less) also require one fixture with a receptacle. Four
fixtures (400 watt) require two fixtures with receptacles.
s
Mounting Configuration
s s s s
s
Fixturewith photocell receptacle
s slave unit(s). 2B 4C 4C
Allowable Wattage per fixture: 150-400W 150-250W 400W

6 Poles See Kim Pole Catalog for a complete selection of square and round poles in aluminum or steel.

5 KIM LIGHTING

Você também pode gostar