S10K
SONIC CHLORINATOR

INTRODUCTION
The S10k chlorinator is an all vacuum operat-
ed, sonically regulated unit. Direct cylinder
mounting puts the vacuum-regulating valve
right at the source, reducing gas pressure to a
vacuum immediately. It provides for econom-
ic low capacity gas feed applications for
municipal and industrial water and waste-
water treatment and disinfection, swimming
pools and industrial process water. Its ability to
handle all water treatment gases as well as its
flexible mounting configurations for cylinders,
manifolds or ton containers provides versatili- Unique Secondary Check design is used for ammonia cylinders. A
ty for all installations. Two basic arrangements The 500 PPD regulator includes a ton container kit includes a drip leg, to
are available in capacities of 200 and 500 unique secondary check designed to trap initial spurts of liquid, a heater for
pounds per day of chlorine gas. With fewer confine gas under pressure should the evaporation and a replaceable filter.
internal parts, you can be confident that the primary valve seat not completely due to
S10k will provide reliable, dependable service. contamination. This minimizes the Handles all Water Treatment
possibility of venting gas to atmosphere. Gases
FEATURES The unit can handle all typical water
Positive Indication of Built-in Automatic Switchover treatment gases e.g. chlorine, sulfur
Operating Status Built-in switchover eliminates the need dioxide, carbon dioxide and ammonia.
for external switching devices. The non-
isolating feature allows cylinders to be Detachable Rotameters

standby* operating empty off


emptied thoroughly, for complete gas Two sizes of rotameters, 3” and 5”, are
consumption. available in 15 capacities between 1.2
Easy to read icons provide positive indi- 500 PPD chlorine (comparable capaci-
cation of cylinder status. The operator Captive Universal Yoke ties for other gases). These
can tell at a glance whether the container Mounting flowmeters can be integral to
is in the standby status (for automatic A unique self aligning captive yoke the unit, or mounted remote,
switchover) operating, empty or off. clamp makes it easy to line up and con- fo rinstallation flexi-
nect the chlorinator to the gasketed out- bility. Rotameters
Positive Shutoff can be ganged
let of a container valve. The rugged
An OFF position on the face of the regu- together for multiple
yoke is designed to Chlorine Institute
lator allows for positive shutoff. Containers points of
recommenda-
can be changed without admitting air, application.
tion per drawing
dirt or moisture into the control unit and
189. A similar
without shutting off the injector.
captive yoke
TECHNICAL DATA

Easy to Install, Operate and is 300 psi to a maximum of 100º F; 150 • Control Logic: Proportional and
Maintain psi to a maximum of 130º F. integral with lag
The S10k chlorinator is simple in • Alarms: 4 user-configurable alarms
design, compact and easy to handle. Pressure at Application Point for 16 different conditions
Injector installation only requires con- Maximum pressure with hose or poly-
necting to a water supply and running ethylene tubing is 75 psi. High pressure OPTIONS
plastic tubing to a main or open chan- hose or rigid pipe will allow application Related options include: cylinder valves
nel. A knob adjustment on the rotame- against back pressure of 75 to 160 psi. and connections; header valves with
ter changes gas feed rate, which is indi- A solution pump after the injector will manifolding and connections; vent; injec-
cated on a high resolution 3" or 5" scale. allow application against higher pressure. tor water and injector outlet lines and
clamps; main connections; solenoid
Accuracy Swimming Pools valves; water line pressure gauge; high
Gas feed is ± 4% of the indicated flow. For non-residential swimming pool vacuum pressure switch and alarm; gas
applications a unique package is available. mask; chlorine detectors; on line
Operating Range analysers; two cylinder scales; residual test
Manual 20:1 for any flowmeter. AUTOMATIC CONTROL kits; injector vacuum gauges; spare parts.
Automatic 10:1. The S10k can accommodate automatic
feed rate control from simple to com- Chlorine Gas Warning
Control Modes plex schemes. The control system con- All unattended chlorine gas containers
Manual control, start-stop or program, sists of an actuator and either SCU and chlorination equipment should be
flow proportional, direct residual, com- (Signal Conditioning Unit) or PCU monitored for leaks. Sensitive chlorine
pound-loop, multiple rate control and (Process Control Unit). detectors, which respond quickly to
multiple point operation. SCU (see TI 40.100UA) chlorine in the atmosphere, should be
• Operating Modes: Flow proportional, installed at each site.
Distance, Supply to the manual See Technical Data Sheet TI 50.130UA
Control Unit • Inputs: 4-20 mA DC (from flow for further details.
For flexibility, it is not necessary to install transmitter)
the vacuum regulating valve close to the • Outputs: Control out to actuator; also Carbon Dioxide Warning
control unit. It can be up to several 4-20 mA output for retransmission of Because of the high pressure in carbon
hundred feet from the gas control unit, gas feed rate (actuator position) dioxide containers, the vacuum regulat-
depending on maximum feed rate, the • Control Capability: Dosage and flow ing valve cannot be mounted directly on
diameter of the connecting pipe or tub- scaling PCU (see TI 40.200UA) the container. A pressure reducing valve
ing and system performance requirements. • Operating Modes: Direct residual feed and pressure relief valve must be
back, compound loop, feed forward, installed between the container and the
Injector Operating Water flow proportional, manual vacuum regulating valve.
Injector operating water must be reason- • Ranges: Setpoints up to 50 mg/l and
ably clean. Injectors are fixed-throat dif- center-zero capability for dechlorination
ferential type. Maximum inlet pressure

2
TECHNICAL DATA

Association recommendations. 7-1/8”


Compliance OVERALL DIMENSIONS Shipping Weight
Gas feeders, controller and actuator are Chlorinator: Gas metering unit - 5 lb.
designed to conform to all applicable 3” Rotameter - 7-7/8” x 7” x 11-3/4” Automatic panel - 16 lb.
NEC and NEMA specifications and 5” Rotameter - 8-1/4” x 12” x 13”
Chlorine Institute and Compressed Gas Automatic panel - 25-1/4” x 7-3/8” x

Connections
Pipe and plastic tubing sizes.

Vacuum Regulating Valves

Tubing to 200 lb 500 lb

control unit 3/8” x 1/2” 1/2" x 5/8"

gas inlet is yoke connection


to a cylinder or header valve
container valve
or, with optional adapter,
to a ton container valve

Injectors

Connection 200 lb 500 lb

3/4” male NPT or


water inlet 1” female NPT
3/4” flexible pipe

3/4" NPT with


water outlet same as inlet adaptors for 3/4”, 1”,
or 1-1/2” pipe or hose

Gases and Capacities*


Maximum Chlorine Carbon Dioxide Sulfur Dioxide Ammonia
capacity lb/24 hour lb/24 hour lb/24 hour lb/24 hour

1.2/4/10/20/50/ 1/3/8/15/40/80/ 1.2/4/10/20/50/ 0.5/2/5/9/25/


3” tube 200 PPD
100/150/200 120/150 100/150/200 50/70/100

3/10/20/30/50/ 2.4/8/15/24/35/58/ 3/10/20/30/50/ 1.4/4.5/9/14/35/


5” tube 500 PPD 75/100/150/200/ 75/116/150/ 75/100/150/200/ 45/70/90/120/
250/300/400/500 200/230/300/390 250/300/400/475 140/190/240

*A selection of tubes in metric calibrations are also available on request


3
S10K CHLORINATOR
EQUIPMENT SPECIFICATION

1.0 GENERAL DESCRIPTION check to prevent gas under pressure injector shall be capable of feeding
The gas feeder shall be a Wallace & from venting into the atmosphere. The against a back pressure of ( ) psi
Tiernan Products S10k. It shall be a vac- check valve shall close in the event of with an operating pressure of ( )
uum operated sonically regulated type leakage past the primary valve. psi. It shall include built-in double
system consisting of a vacuum regulator, check valve protection to prevent water
flowmeter with rate valve and injector. It 2.2 Automatic Switchover from back flooding into the vacuum
shall have a maximum capacity of (200) An automatic switchover system shall be regulator. The injector shall include an
(500) ( ) pounds per day (chlo- furnished to change over to a new sup- integral mounting bracket. It shall be
rine) (sulfur dioxide) (ammonia) (carbon ply as the on-line supply is depleted. A capable of mounting in either the verti-
dioxide) and sized to feed ( ) pair of vacuum regulating valves with cal or horizontal plane.
PPD. It shall be (manually) (automati- built-in switchover capability shall be
cally) controlled having a feed range of furnished. The regulator valve shall 5.0 AUTOMATIC CONTROLS
(20:1 manual) (10:1 automatic) and the include a mechanical detent to keep the Each gas feeder shall be provided with
capability to control within ±4% of the standby gas supply ready for on-line ser- an integral automatic control system
indicated feed rate. vice. When the switchover is accom- consisting of a dedicated electronic con-
plished gas shall continue to be drawn troller, a V-notch positioner, a 5”
2.0 VACUUM REGULATOR from the former source until the con- rotameter and a V-notch chamber. The
2.1 Design tainer(s) are empty. A separate positioner shall move the V-notch plug
The (cylinder) (manifold) (ton container) switchover device will not be acceptable. and shall contain a reversible motor
mounted vacuum regulator shall be Each regulator shall include easy to read with thermal overload protection,
rated for (200PPD) (500 PPD) indication of stand-by, operating, empty mechanical override, feedback poten-
( PPD) of chlorine ( ). It shall and off position. tiometer, selectable contacts and front
consist of a vacuum regulator designed accessibility for service. The positioner,
to reduce full supply pressure to a vacu- 3.0 CONTROL UNIT V-notch chamber and 5” rotameter shall
um without venting. A self aligning A (3 inch) (5 inch) flowmeter assembly be mounted remote from the gas storage
yoke shall be provided as an integral with a V-notch rate valve shall be fur- area. The positioner and controller shall
part of the vacuum regulator. The unit nished and shall be capable of local or be housed in NEMA 4X enclosures.
shall include a selector knob and icons remote mounting. There shall be provi-
to indicate the chlorine gas container sions for interlocking flowmeter frames 5.1 SCU Flow Proportional
status. An off position shall be provided for multiple feed points. The flowmeter Controller
to isolate the diaphragm and internal tube shall be serviceable without remov- The Flow Proportional Controller shall
components from atmospheric air when ing the frame from its mounting. be microprocessor-based with a NEMA
the operator changes containers. 4X enclosure. It shall accept a 4-20 mA
It shall contain internal pressure relief. 4.0 INJECTOR process variable input signal. The user
[It shall contain a drip leg with remov- Each gas feeder shall have a PVC (3/4) interface shall include a membrane key-
able filter and 110 volt heater for (1) inch fixed throat injector rated (200 pad and backlit LCD display.
mounting on a ton container]. The 500 PPD) (500 PPD) to generate the
PPD unit shall include a secondary operating vacuum for the system. The Equipment specifications continued on page 5.
4
S10K CHLORINATOR
EQUIPMENT SPECIFICATION

The display shall be scrollable to five Four configurable alarm relays shall be
operating menus as follows: provided to select from 16 different
(1) Main Menu shall display values alarm conditions.
(2) Setup Menu The controller shall have password pro-
(3) Input and Output options tection to prevent tampering. The unit
(4) Diagnostic Menu for trouble shooting shall be capable of computer interface
(5) Calibration Menu. via RS485 serial communication. An
Dosage can be set from 10 to 400% of isolated 4-20 mA output signal shall be
intput. An isolated 4-20 mA output sig- provided for control, flow or actuator
nal shall be provided for control, flow or position. The controller shall be a
actuator position. The controller shall be PCU (Process Control Unit) as manu- 1” Injector - Capacity to 500 PPD
an SCU (Signal Conditioning Unit) as factured by Wallace & Tiernan
manufactured by Wallace & Tiernan Products.
Products.
6.0 ACCESSORIES
– OR – A vacuum switch shall be supplied to
actuate on loss of gas pressure. It shall
5.2 PCU Compound Loop be designed for mounting integral to the
Controller vacuum regulator and shall be supplied
The Compound Loop Controller shall with one normally opened, normally
be microprocessor based and capable of closed contact rated at 10 amps.
accepting 3 input signals: flow, residual
and one spare. It shall have a membrane 3/4” Injector - Capacity to 200 PPD
keypad, digital LED display of residual,
LED bar graph display of percent valve
position and 16 character alphanumeric
LED display of all operating and setup
parameters.
The user shall be able to select from six
modes of operation:
(1) direct residual control
(2) compound loop control
(3) dual signal feed forward control for
dechlorination
(4) center zero control for dechlorination
(5) flow proportional control
(6) manual control.
5
TECHNICAL INFORMATION

S10K
SONIC CHLORINATOR

Taking care of the world's water.


Wallace & Tiernan Products
1901 West Garden Road
Vineland, NJ 08360
856.507.9000 tel
856.507.4125 fax
Progressive changes in design may be made
www.wallaceandtiernan.usfilter.com
without prior announcements. Literature # TI 25.200 UA 9/99
©1999 United States Filter Corporation
6