Escolar Documentos
Profissional Documentos
Cultura Documentos
discussions, stats, and author profiles for this publication at: https://www.researchgate.net/publication/6170431
CITATIONS READS
32 175
4 authors, including:
Some of the authors of this publication are also working on these related projects:
All content following this page was uploaded by B Duncan X Lascelles on 06 January 2015.
The user has requested enhancement of the downloaded file. All in-text references underlined in blue are added to the original document
and are linked to publications on ResearchGate, letting you access and read them immediately.
Validity of goniometric joint measurements
in cats
Gayle H. Jaeger, DVM, MSpVM; Denis J. Marcellin-Little, DEDV; Venita DePuy, MStat;
B. Duncan X. Lascelles, BVSc, PhD
Objective—To compare and validate goniometric joint measurements obtained from non-
sedated and sedated cats with measurements from radiographic evaluation.
Animals—20 adult cats with no evidence of joint disease.
Procedures—Measurements of flexion and extension of the carpus, elbow, shoulder,
tarsus, stifle, and hip joints and of carpal and tarsal joints during varus and valgus angu-
lation were made by a single investigator before and after sedation of cats. Measure-
ments were made by use of a goniometer with a masked dial. Joint angle measure-
ments were compared between nonsedated and sedated cats and also with measure-
ments from radiographs made while cats were sedated. Each series of measurements
was repeated 4 times. To evaluate repeatability, Cronbach α values were calculated for
repeated measure results of goniometric joint measurements of nonsedated and se-
dated cats. An intraclass correlation was calculated to determine reliability among the
3 measurement types (ie, measurements from nonsedated and sedated cats and on
radiographic evaluation).
Results—Joint measurements did not differ significantly by measurement type, when
comparing radiographic measurements with goniometric measurements in sedated and
nonsedated cats. Cronbach α values were > 0.99 for goniometric joint measurements with-
in individual nonsedated and sedated cats and also for comparison of mean meaurements
obtained from sedated cats versus nonsedated cats versus radiographs. An intraclass cor-
relation of 0.999 revealed high reliability among measurement types.
Conclusions and Clinical Relevance—Results indicated that goniometric joint measurements
in nonsedated and sedated cats are repeatable and valid. (Am J Vet Res 2007;68:822–826)
Table 1—Angle measurements of joints to determine ROM in 20 cats without sedation, during sedation, and on radiographic
evaluation.
CI = Confidence interval. CV = Coefficient of variation. Non = Nonsedated cats. Sed = Sedated cats. Rad = Radiographs. Flex = Flexion. Ext =
Extension. Val = Valgus angulation. Var = Varus angulation.
Appendix
Landmarks for performing goniometric joint measurements in appendicular joints of cats.
Stifle Flex-Ext Longitudinal axis of the tibia Longitudinal axis of the femur (from the lateral femoral epicondyle NA
to the greater trochanter)
Hip Flex-Ext Longitudinal axis of the femur A line parallel to a line joining the tuber sacrale and tuber ischiadicum NA
over the greater trochanter
COR = Center of rotation. Flex-Ext = Flexion and extension. Val-Var = Valgus and varus angulation. NA = Not applicable.