PASSENGER ELEVATORS - We reserve the right to change designs and specifications for the product development without prior notice.
Copyright ⵒ HYUNDAI ELEVATOR CO., LTD. All rights reserved. Printed in Korea.
CATALOG CODE : C-PELA-E0108/2012.12/1st Edition
Hyundai Elevator
Hyundai Elevator, an affiliated company of Hyundai Group,
offers its products in more than 50 countries such as the United States, Canada,
Japan, Europe, East/West Asia, the Middle East and is recognized for excellence in
quality. Hyundai elevators and escalators are known for their exceptional comfort,
safety and energy efficiency.
Hyundai Elevator Head Office_The World Class Elevator Test Tower (Hyundai Asan Tower) stands in Icheon, Korea
Company Profile
Incorporated : May 23, 1984
Number of Employees : 1,304(As of September, 1, 2012)
Test Tower
350(1.75)
Standing 672ft(205m) high, our ultra- high speed test tower, named the
Hyundai Asan Tower, was completed in April 2009 and is used to test for
vibration, noise, pressure, as well as the reliability and safety of the parts and
components related to ultrahigh speed systems.
200(1.0)
At the Hyundai Asan Tower, you will find the world’s fastest elevator running
at speeds up to 3600fpm(18m/sec), as well as the 2000fpm(10m/sec), high speed double
deck elevator, and the world’s fastest 1400fpm(7m/sec) high speed observation elevator.
150(0.75)
Contents
01 Reliable Products YZERⰺ04 / LUXENⰺ06
02 Advanced Technology Gearless Traction Machineⰺ08
03 Design Design Collectionⰺ10 / Ceiling Design & Handrailⰺ17 / Signal Fixturesⰺ18 * MRL: Machine-room-less
Standard & Optional Featuresⰺ20 / Layout Planⰺ22 / Entrance Designⰺ26 / Power Feeder Dataⰺ28 / Works To Be Done By Other Contractorsⰺ29
HYUNDAI ELEVATOR RELIABLE PRODUCTS
01Reliable Products
Machine-room-less
elevators (YZER)
The machine roomless elevator YZER is a revolutionary new elevator that eliminates
the need for a rooftop machine room through the use of miniaturized traction machines and control panels,
allowing increased space utilization, resolution of height and sunlight restriction issues, and more freedom
in installation layout and skyline design.
01Reliable Products
elevators (LUXEN)
The LUXEN incorporates a high quality gearless traction machine to a mid/low speed elevator,
resulting in highly efficient controls and energy savings. Also, continuous noise and vibration analysis
have resulted in increased passenger comfort and a quiet and pleasant ride.
Energy efficiency
Gearless traction machine with permanent magnet synchronous
motor increases energy efficiency.
Eco-friendly
Environmentally-friendly elevator that does not need regular gear
oil replacement.
02 Advanced Technology
Gearless
Traction Machine
With the use of gearless traction machine, smoother ride, improved energy-saving,
and environment-friendly features are enhanced.
Comfortable ride
Noise and vibration level has decreased dramatically and
car ride has improved significantly with the use of gearless traction machines
with permanent magnet synchronous motors thanks to the lack of tooth
gear and rope swing.
Environment-friendly components
Gearless traction machine is environment-friendly since gear oil is not
required.
03Design Collection
REAR VIEW REAR VIEW
03Design Collection
REAR VIEW REAR VIEW
03Design Collection
REAR VIEW REAR VIEW
Ceiling
CD219A CD251A
Painted Steel(P022), Skylite 10T Painted Steel(P022),
Acrylic, Convective Air Sterilization System
CD299B CD329B
Painted Steel(P023), LED Light, Painted Steel(P022), Skylite 10T,
LED Down Light, Skylite 10T LED Down Light
Handrail
FRONT VIEW ENTRANCE
No Smoking
03 Signal Fixtures
Fire Service Indicator
HPBU- 230B HPBU- 230BK HPIU-D310
FIREFIGHTER'S
SERVICE
Firefighter's Cabinet
ANSI 2004 / 05 / 07
OFF OFF
Function Switch
H H
L I L I
O G O G
W H W H
FAN FAN
11 11 12 12
9 9 10 10
7 7 8 8
5 5 6 6
Push Button
3 3 4 4
1 1 2 2
DOOR DOOR
OPEN CLOSE
S
R
T
ALARM STOP U
N
O
P
NO SMOKING No Smoking,
CAPACITY 2500 LBS
ELEV NO. 01 Capacity and Elevator Number
MAIN SUB
(Optional)
Note : At least one 'No Smoking' sign is required. Two or more 'No Smoking' sign is optional.
P016 (9.9YR 5.0/3.1) P019 (5.1Y 7.6/1.1) P020 (Metallic Gold) P021 (Metallic Silver) P022 (Black) P023
The first call determines the direction of the elevator. All calls opposing the respective During the operation if the car stops between floors, and safety device doesn’t work,
1) Selective collective ⷃ
direction are serviced after carrying out by the calls of the respective direction. 12) Safety drive the car automatically moves to the nearest floor with the low speed. Then, it opens the ⷃ
door to allow the passengers to exit off.
2) Duplex selective
2 units of elevator provide the effective service for the common hall calls. ⷈ
collective 13) Multi-beam door Multi-beam from the top to the bottom of the door senses any obstruction caught in the
ⷈ
protection door. It makes the door reopen and stay open until the obstruction is removed.
When a car is 80% loaded, it will automatically bypass all hall calls as the bypass load
3) Automatic bypass ⷃ
weighing device is activated. When a fire breaks out, all cars activated by the switch or fire detector are immediately
14) Fire emergency service ⷈ
called to a specified rescue floor for the passenger’s safety.
4) Arrival Voice It provides an audible indication in the car that an elevator is about to arrive. ⷃ Evaluates the number of people on the car and compares that value to the number of the
car calls registered. If the number of car calls exceeds the number of people in the car by
15) Anti-nuisance ⷈ
the load sensor, the car call exceeding the number of passengers will be cancelled after
service nearest call only.
Dot matrix type(moving direction) ⷃ
5) Signal fixtures
Hall lantern ⷈ
A voice synthesizer with microprocessor makes announcements to inform passengers
16) Voice synthesizer ⷃ
of various conditions, including landing floor and operation direction, etc.
Contact with a passenger or inanimate object causes the doors to stop and
6) Single-side safety
reopen automatically. ⷃ
edge of door The elevator doesn’t start if the door is not completely closed.
When the fireman’s switch located at the main floor lobby and operating panel on the
17) Fireman’s emergency
car is activated during a fire or other emergency, a designated car can be called back to a ⷈ
service specified floor for fire fighting service.
7) Ventilation fan Car ventilation is smooth with ventilation fan built-in the ceiling. ⷃ
9) Automatic interruption of The lights and ventilation fan are automatically turned off to save energy if there is It is activated when the attendant turns on the ATT switch in the car operating panel to
ⷃ 19) Attendant service ⷈ
light and ventilation fan no call registered for a period of time. If there is a call registered again, it works again. tONu position.
When the door is opened, the switch installed at the door operator is activated and
10) Car door When the seismic sensor detects and earthquake that exceeds a predetermined level,
keeps the car from moving. During the operation of car, it locks the door completely so as ⷃ
interlock switch 20) Earthquake operation all cars promptly proceed to land at the nearest floor and park with the doors open to ⷈ
not to open the door from out side.
allow passengers to exit out safely.
To protect the overload of an elevator, this device sounds a buzzer and the elevator
remains stopped at that floor when the number of passengers exceeds the rated
11) Overload features ⷃ With the use of the parking switch on the hall button, the car can be parked at a
capacity. When the excess number of passengers get out of the car, the buzzer stops 21) Parking ⷈ
and the elevator door closes. specified floor, during nights and holidays.
Trolley beam
(By others) Unit : feet-inch(mm)
Min.5'-41/8" (1628)
Min.5'-9" (1753)
Double Door
Overhead(OH)
(kg) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm)
Control
Panel
150/200 (45/60)
SS: 2100 3'-0" 5'-8" 7'-7" 15'-61/16" 23'-51/ 8"
Clear Opening
7' (2134)
Single Slide (953) (914) (1727) (2311) (4726) (7141)
350 (105)
X X 4'-3" 6'-6" 6'-7"
(1295) (1981) (2007)
X1 Min.5'(1524) Minimum Control 150/200 (45/60)
Space Requirements 2500 3'-6"
For One Car (1134) (1067)
350 (105)
R1 SS:
R2
Varies 150/200 (45/60) Single Slide
3000 3'-6" 6'-8" 4'-9" 8'-7" 17'-6" 26'-5" 7'-0" 7'-1"
CA
(1361) (1067) (2032) (1448) (2616) (5334) (8052) (2134) (2159)
Control
CB
R3
5'-8 7/ 8" (1750)
Travel (TR)
Panel
JJ 3' (914) X
Notes : 1. Speed : 150/200fpm(45/60mpm), 350fpm(105mpm)
Minimum Control 2. Maximum travel : 200'(200fpm) or 245'(350fpm)
Room Requirements (W)3'x(H)7' 3. Max number of stops : 20(200fpm) or 24(350fpm)
M/C Room Entrance Section X-X 4. Car height 8'(2438mm) Standard, 9'(2743mm), 10' (3028mm) Optional
For One Car (By others) 5. Entrance height : 7'(2134mm) Standard
6. Machine is located at the top and off to the side.
7. Double door not available.
X2 Min.7' (2134)
X1 4" (102) X1
X
CA CA
Y
Y
CB
Inspection Receptacle
Control
Panel
By others
Unit : feet-inch(mm)
CWT CAR Inspection Ladder
By others
M/C Room Reaction
Cinder Concrete & Rated Speed Capacity Overhead Pit Pit Reaction
JJ JJ 3' (914) X Water Proofed Finish Reaction Force (kN) Suspension Load (kN)
(W)3'x(H)7'
By others
fpm (mpm)
M/C Room Entrance
Minimum Control (By others) Lbs (kg) OH (mm) PP (mm) CAR (kN) CWT (kN) R1 R2 R3 R4 Trolley1 (TM) Trolley2 (CAR)
Room Requirements
For Two Car 150/200 (45/60) 13'-9" (4191) 5'-0" (1524) 71 57
2100
65 65 14 24 20 66
(953)
X3 Min.8'-4" (2540) 350 (105) 14'-6" (4420) 5'-5" (1651) 91 73
X1 4" (102) X1 4" (102) X1 150/200 (45/60) 13'-9" (4191) 5'-0" (1524) 81 64
X 2500
70 70 15 26 20 72
(1134)
350 (105) 14'-6" (4420) 5'-5" (1651) 104 82
Control
Panel
150/200 (45/60) 13'-9" (4191) 5'-0" (1524) 90 70
3000
CA CA CA 76 76 16 27 20 79
(1361)
350 (105) 14'-6" (4420) 5'-5" (1651) 115 89
CB
Y
Y
Control
Control
Panel
Panel
Unit : feet-inch(mm)
Clear Car Inside Clear Minimum Hoistway Dimension Minimum Machine Room Dimension
MX1 Capacity
Opening Dimension 1 Car 2 Cars 3 Cars Depth 1 Car 2 Cars 3 Cars Depth
X1 Rated Speed Door
fpm (mpm) Type
Lbs OP CA CB X1 X2 X3 Y (SO) Y (CO) MX1 MX2 MX3 Y
"A"
RA CA RB
150/200 (45/60) SS:
CB
2100 3'-0" 5'-8" 8'-31/ 2" 16'-11" 25'-61/ 2" 9'-31/ 2" 18'-11" 27'-61/ 2"
Y
Single
(953) (914) (1727) (2527) (5156) (7785) (2832) (5766) (8395)
350 (105) Slide
4'-3" 5'-6" 5'-73 /16" 10'-6"
MY
Single
150/200 (45/60) Slide
Overhead (OH)
3000 3'-6" 6'-8" 4'-9" 6'-0" 6'-11/4" 11'-0"
(W)3' x (H)7' (1361) (1067) (2032) (1448) (1829) (1860) (3353)
350 (105) CO:
M/C Room Entrance Power Source & Switch 9'-31/ 2" 18'-11" 28'-61/ 2" 10'-31/ 2" 20'-11" 30'-61/ 2"
(By others) Center
(By others) (2832) (5766) (8700) (3137) (6376) (9309)
150/200 (45/60) Open
3500
(1588)
350 (105)
MX2 5'-5" 6'-8" 6'-9 1/4" 11'-8"
(1651) (2032) (2063) (3556)
Clear Opening
150/200 (45/60) CO:
7' (2134)
X2
4000 4'-0" 7'-8" 10'-31/ 2" 20'-11" 31'-61/ 2" 11'-31/ 2" 22'-11" 33'-61/ 2"
Center
(1814) (1219) (2337) (3137) (6376) (9614) ( 3442) (6985) (10224)
X1 4" (102) X1 350 (105) Open
JJ JJ
Control Control
Travel (TR)
Panel Panel
Unit : feet-inch(mm)
(W)3' x (H)7'
M/C Room Entrance Power Source & Switch
(By others) (By others) Rated speed Capacity Overhead Pit Pit Reaction M/C Room Reaction
fpm (mpm) Lbs (kg) OH (mm) PP (mm) CAR (kN) CWT (kN) RA (kN) RB (kN)
MX3
150/200 (45/60) 14'-1" (4293) 5'-3" (1600) 70 56
2100
X3 58 105
(953)
350 (105) 14'-7" (4445) 5'-6" (1676) 90 72
X1 4" (102) X1 4" (102) X1
150/200 (45/60) 14'-1" (4293) 5'-3" (1600) 82 65
2500
60 113
(1134)
Pit Depth (PP)
3000
66 122
(1361)
350 (105) 14'-7" (4445) 5'-6" (1676) 116 90
MY
Inspection Receptacle
JJ JJ JJ (By others)
150/200 (45/60) 14'-1" (4293) 5'-3" (1600) 86 65
CWT CAR 3500
Inspection Ladder 70 129
Control
(1588)
Panel
43 /4" (121)
39 /16" (90)
depth
Jamb
depth
Jamb
Thickness
Thickness
Wall
Wall
AJP150 AJP150
(Wide Straight & Bolted)
Thickness
Thickness
Finish
13 /16" (30)
Finish
13 /16" (30)
Standard Door Frame (Jamb) Standard Door Frame (Jamb)
Finished wall Finished wall
(By Others) (By Others)
4" Clear Opening 4" 4" Clear Opening 4"
(102) JJ (102) (102) JJ (102)
39 /16" (90)
43 /4" (121)
depth
Jamb
depth
Jamb
Thickness
Thickness
Wall
Wall
AJP150S AJP150S
(Wide Angled & Bolted) (Wide Angled & Bolted)
Standard Door Frame (Jamb)
Thickness
Thickness
Finish
Finish
Finished wall Finished wall
(By Others) (By Others)
6" Clear Opening 6" 6" Clear Opening 6"
(152) JJ (152) (152) JJ (152)
(102)
4"
4"
Concrete Opening
Concrete Opening
HH (Std : 7' (2134))
Clear Opening
Clear Opening
Clear Opening
OFF OFF
BYPASS
BYPASS
O O
N N
HH+4"
FIREMAN FIREMAN
HH+4"
HH
HH
Jamb Jamb
depth depth
B B B B
A A
A A