Você está na página 1de 21
oO M INVERTER INVERTER SYSTEM INSIDE TREINAMENTO~ F YOU GI ——_—_ NN-G62B | NN-S62B |NN-G52B |NN-S52B | NN-S42B Tecnoctocin | AWERTER. INVER INVERTER, INVERTER. CONVENCIONAL ——“~ BH> 110 BH > 10v BH t10v BH tov BH > 110. ALIVENTAGAO | ax > 220V BK > 220V BK 220V BK > 2207 BK > 220V. POTENCIA s00w 1000 s00W s00W 800W | FREQ. OPERACAO | 2480MHz 2450MH 2450MHz 2450MHz 2450MH2 TEMPORIZADOR | 98mine$9seq | 99mine 950g. | S4mine9deeg | 99mino99s0q | 99min e S9seg CAPACIDADE 31 tiros 36litros, 25 litros 28 litros 2iitros PESO wnoxmano) | 13,5Kg 12Kg 11,5Kg 11Kg 14K Gréfica do Acompanhamenio - 10 principals pegas ‘adata: Nico a vas Saigo FO oS i OO ORTON OT TAT a | —arettbsar RAR ORINASOR q " tnt 2a 22a SEACH are —— Pave SAE CSE q a — ff — tt uae SPoTCHOO CONURTO FORE a q jt {14 THRONE THENDRaNE od —of — a — oe im (itary —|-——Te08 MEN STAT tot tt tt at (amar Posie 333} — 14 t—t—4 at SHIT TASCA OK FORT a tt 4 ae (ere TORU OPIN CEST 39 —ot — 1 —4 aap aes inane at —4— 7 | 3 ES HTL vaa7 —| TET ORC DE AUATER — 1 at tt SP omy stich 4 Gralfico da Acompanhamento - 10 principals povas he ee Se = oe ee pe Seb ea = EIS SEE > >| OPERA APENAS COM DOIS NIVEIS DE POTENCIA, OU O MICROONDAS ESTA LIGADO OU DESUGADO ; INVERTER > UTILIZA MULTIPLOS NIVEIS DE POTENCIA EGONOMIA DE ENERGIA ENTRADA ENTRADA SAIDA __SAIDA sow wow | Co | * a (61%) Tee (71%) Convencional INVERTER NOVO CIRCUITO INVERTER TRANSFORMADOR E CAPACITOR DE ALTA TENSAO , PC DAPOLPANEL PUL PO td HE —p P/PLALA INVERTER 9 porn yyg | 440 7% P/PC) paiue PHD ¢ Bef M ENTRA PLACA INVERTER ») "jj? 447 SISTEMA CONVENCIONAL TENSAO DA REDE /~ / DETECTA BAIXA VOLTAGEM CHAVEAMENTO E START POTENCIA PULSO PWM E 7 REALIMENTAGAO. i aK wpo4 en aoe Gata DECa MENTE ECTES TRANSICITORS ESTAO LIGADOS NA CONFIGURACAO COMPLEMENTAR E TEM COMO FINALIDADE PROPORCIONAR UM GANIIO DE CORRENTE & NA BAGE DEQ 704 are CIRCUITO INVERTER PULSO PWME REAUMENTAGAO ie DETECTA BAIXA VOLTAGEM, MENOS QUE 30% PULSO PWME REALIMENTAGAO CIRCUITO INVERTER =O IGBT'e SAO COMPONESTES USADOS —PRINCIPALMENTE = COMO COMUTADORES EM CONVERSORES DE FREQUENCIA, INVERSORES ETC. ff ESTAS APLICACOES, NORMALMENTE UMA CARGA INDUTIVA E LIGADA E DEGLICADA, PODENDO COM ISSO APARECER TENSOES INVERSAS, QUE E CASO DO CIRCUITO INVERTER... co CONTROLE DE QO! a Q702, PARA ATENDER AS NECESSIDADES DO CIRCUITO INVERTER TEM QUE OPERAR COM GRANDES CORRENTES, ALTA FREQUENCIAG E ELEVADA TENSAO REVERSA. PARA ATENDER AS ESPECIFICACOES, DO CIRCUITO AO INVES DOS TEP (TRANSISTOR BIPOLAR DE POTENCIA) FORAM ADOTADOS OS IBGT (INSULATED GATE BIPOLAR TRANSISTOR - TRNSISTOR BIPOLAR DE PORTA ISOLADA)... ANALISE DO CIRCUITO QUANDO: Q7020FF e Q701 > ON Det case Lien do. PLACA K ores CIRCUITO INVERTER FE CHAO (pees ce Tos hn se | Se oie bse 2 7 | Leto ANALISE DO CIRCUITO QUANDO: Q7020N e Q701 > OFF PLACA K Jebel phen “Dh come ROLE BE EREOYE cia) Pol PEL PERM Coe g AB COME FRED ane wir/pork Saas OH bu 1 Na we iz Papa {ode PO! pasHEl RE rap CIRCUITO INVERTER a TENSAO BOBINA RETIFICADOR, P| oc || cHoaue | 1 ii ITRANSITOR| || TRAFO. {“) car (aT TRAFO (| . L CORRENTE REALIMENTACAO SAIDA + j{COMPARADOR. a CONTROLADA CUIDADOS ESPECIAS ESTE TRIMPOT JA VEM PRE AJUSTADO DE FABRICA, EE RESPONGAVEL PELO CONTROLE DE POTENCIA ATENCAO: EM HIPOTESE ALGUMA DEVE SER MEXIDO ANTES DO REPARO DE QUALQUER COMPONENTE OU FIACAO DO FORNO DESCONECTE 0 CABO ACE DESCARREGUE OS CAPACITORES DE ALTA CONFORME INDICADO AO LADO NAO AQUECE NORMALMENTE OS FORNOS COM ESTE SINTOMA, DESCONSIDERANDO VARIACAO NA TENSAO DE ENTRADA, NORMALMENTE COSTUMA SER 0 MAGNETRON COM DEFEITO FACA 0 TECTE DE CONTINUIDADE PARA CERTIFICAR- SE QUANTO AO ESTADO DO MACNETRON FILAMENTO - FILAMENTO 0Q FILAMENTO - CARCACA ABERTO DESLIGANDO APOS 3 SEGUNDO Q701e 0702 Q701 OU Q702 EM CURTO OU EM FUGA PORTANTO » SEMPRE QUE NECESCARIO TROQUE 0 DOIS IGBT's (Q701 © Q702) EM CONJUNTO. 1GBT2 = A trawziston Bipods pe Porte rz0Lana- ro y COMO MEDIR Q701 EQ702 PARA 0S MODELOS 110V MULTIMETRO fe im MULTIMETR' DESLIGANDO APOS 3 SEGUNDOS 0701 0702 OUT) O18 i COLETOR GATE 268K | 5,90K0 EMISSOR GATE 9.8KQ 610KQ Emisson | coteror | 15.2KQ 610KQ GATE COLETOR 16K 5,90KQ. GATE EMISSOR 98K ABERTO COLETOR =| — EMISSOR 161KQ |} ABERTO DESLIGANDO APOS 2 SEGUNDO 1g COMO MEDIR Q701 EQ702 PARA OS MODELOS 220V Q701 6 0702 LUMLECULOM 0701 Qn COLETOR GATE %8KQ | 5,90KQ EMISSOR GATE 9.8KQ 610KQ Emissor | coteTor | 15.2KQ | 610K GATE COLETOR 26KQ 5,90KQ. GATE ENISSOR 9.8K0. ABERTO CoveroR | eMisson | 141K | ABERTO DESLIGANDO APOS 3 SEGUNDOS MUITO IMPORTANTE ft . QUANDO Q702 ESTA EM CURTO OU COM FUGA ENTRE GATE — EMISSOR, NORMALMENTE FAZ COM QUE OS RESISTORES DE POLARIZACAO DE GATE SE ABRAM. SE TROCARMOS 08 IBCT’s E NAO NOS ATENTARMOS QUANTO A ISSO 0 FORNO ATE PODERA FUNCIONAR EM LUGARES ONDE 0 NIVEL DE TEN@AO DA REDE NAO E ALTO, MAS COM CERTEZA ISTO ACARRETARA NA QUEIMA DE Q701 OU Q702 NOVAMENTE PORTANTO SEMPRE VERIFIQUE ESTES RESISTORES ANTES DE TROCAR Q701 e Q702 DESLIGANDO APOS 3 SEGUNDOS © RESISTOR DE POLARIZACAO DE GATE QUE NORMALMENTE SE ABRE E 0 R718, E ACONTECE COM MAIS FREQUENCIA NOS MODELOS BH (127) DESLIGANDO APOS 8 SEGUNDOS A PLACA K MONITORA 0 COLETOR DE Q701 E SE ESTA TENSAO ULTRAPASSAR 6OOV 0 CIRCUITO SE DESUGA ATENSAO NO COLETOR DE Q701 PODE AUMENTAR SE 0 ENROLAMENTO DO PRIMARIO DE T701 ESTIVER ALTERADO ENROLAMENTO P701 - P702 ENROLAMENTO H701 - H702 ENROLAMENTO S701 - S702 | 5.0Q | 5.0Q DESLIGANDO APOS. 3-CEGUNDOS JA TIVEMOS ALGUNS CASOS DE MAGNETRON RUIM, E UMA MANEIRA DE ISOLAR O DEFEITO E SOLTAR 0 CONECTOR CN703 E LIGAR 0 FORNO.... .» NESTAS CONDICOES 0 FORNO DEVERIA FUNCIONAR E DESLIGAR EM 23 SEGUNDOS SE 0 FORNO CONTINUAR A SE DESLIGAR EM 3 SEGUNDOS 0 MAGNETRON ESTA BOM é té DESLIGANDO APOS 28 SEGUNDOS APLACA INVERTER MONITORA A TODO TEMPO A CORRENTE DE CONSUMO DO MACNETRON SE POR ACASO 0 VALOR DESTA CORRENTE NAO SEJA SATISFATORIO 0 CIRCUITO APOS ALGUM TEMPO IRA SE DESLIGAR © TEMPO QUE 0 CIRCUITO LEVA PARA DESLIGAR CASO HAJA ALCO DE ANORMAL NA CORRENTE E DE EXATAMENTE 23 SEGUNDOS DESLIGANDO APOS 22 SEGUNDO Muurrag VEZES OS FORNOS COM ESTE SINTOMA NAO SE TRATA DE | UMA PEGA OU COMPONENTE RUIM E SIM DE UM MAU CONTATO NOS CAEOS DO MAGNETRON RESSOLDE 0:CABO DE CONEXAO DO MAGNETRON COM A PLACA INVERTER NO PONTO ONDE E FEITA A CLIPACEM... It DESLIGANDO APOS 23 SEGUNDOS ~-- PROCEDIMENTO PARA A RESSOLDAGEM: CABO COM MAU CONTATO CABO SOLDADO DESLIGANDO APOS 22 SECUNDOS «CASO NAO RESOLVA VERIFIQUE 0 MAGNETRON FILAMENTO - FILAMENTO 00 FILAMENTO - CARCACA ABERTO DESLIGANDO APOS 80 SEGUNDO VERIFIQUE 0 SENSOR DE UMIDADE To = [2A + T2B AT = T2-T1 | ty-_T1A+T1B / 4 AT=12-T1 2 Tre TIA+TIB MODO DE SERVICO 43 MODO DE SERVICO OS FORNOS COM TECNOLOGIA INVERTER NOS PERMITE ATRAVES DO MODO DE SERVICO VERIFICAR © CIRCUITO INVERTER Procedimento: * — Descarregue o circuito de alta tensao da placa inverter, Desligue o conector CN703. Pressione a tecla tempo/reldgio duas vezes e em Seguida a tecla ligar. «Programe o forno para poténcia Alta e tempo de 1 minuto, * — Pressione ligar. * Apés aproximadamente 15 segundos o display ira mostrar H98 e o forno para. * Durante a operagao a corrente de entrada 6 de aproximadamente 1,0 a 1,7A. MODO DE SERVIGO Procetiimento: | Descarregue o circuito de alta tensfio da placa inverter, + Desligue o conector CN704. * _ Pressione a tecla tempo/relégio duas vezes ¢ em seguida a tecla ligar. * Programe o forno para poténcia Alta o tempo de 1 minuto, * Pressione ligar. . : Apés aproximadamente 27 segundos o display ira mostrar H97 ¢ o forno para, + Durante a operagiio a corrente de entrada é de aproximadamente 0,4 a 0,8A, SE OS DOIS TESTES DEREM Ok, PODE-SE CONSIDERAR QUE 0 CIRCUITO INVERTER ESTA OK

Você também pode gostar