OPERATION
User manual
AG-WL10
Indoor unit air/air heat pump
LEK
UHB GB 1715-2
331830
Table of Contents
1 Important information 5
Installation data 5
Safety information 6
Serial number 7
AG-WL10 – an excellent choice 8
Safety instructions 9
Recovery 10
2 Design 11
3 Remote control 13
Before use 13
Overview 15
Remote control display 17
Function without remote control 19
4 Function modes 20
Cooling 20
Heating 21
Automatic mode heat/cooling 22
Dehumidification 25
Ventilation 26
Function in the event of power cut 26
5 Operating program 27
TiO2-air cleaning 27
Night program/energy saving 27
High power-program 27
iFEEL/iFEEL C 28
6 Fan and air flow setting 29
Selecting fan speed 29
Airflow control 30
7 Clock and timer 32
Setting the clock 32
Setting the timer 32
4 Chapter | AG-WL10
1 Important information
Installation data
Indoor unit AG-WL10
Model designation
Installation date
Installer
Outdoor unit
Model designation
Installation date
Installer
Symbols
NOTE
This symbol indicates danger to machine or person.
Caution
This symbol indicates important information about what you should
observe when maintaining your installation.
TIP
This symbol indicates tips on how to facilitate using the product.
PUSH
PUSH
Serial number
Caution
You need the product's (14 digit) serial number for servicing and support.
■ Never install electric equipment that does not have IPX1 protection
(protection against vertical water drops), under the unit.
■ Do not switch the climate unit on or off using the main switch. Always
use the ON/OFF button on the remote control or the function selector
on the unit.
■ Do not allow children to play with the climate unit.
■ Do not cool the room too much if there are young children or disabled
people in the room.
■ The climate unit is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of exper-
ience or knowledge, unless they have been instructed by, or are under
the supervision of, a person who is responsible for the safety of the
climate unit when it is in use.
PUSH
7 8 9
PUSH
3
5 6
2
1
4 10
1. Remote control
2. Temperature sensor: The sensor registers the room temperature and
controls the indoor unit accordingly.
3. Air outlet: The outlet spreads the treated air in the premises.
4. Air intake: The room air is drawn in and passes through the filter that
eliminates the dust.
5. Receiver: It receives signals sent from the remote control.
6. Function selector: Press this button to toggle from one function to
another (OFF, COOL and HEAT).
NOTE
The OFF position does not cut the mains supply. Use the main switch to
cut the power supply to the unit.
7. Function lamp: This lamp lights when the unit is in use. It flashes once
to indicate that the command from the remote control has been re-
ceived.
8. Timer lamp: This lamp goes on when the system is being controlled
by the timer.
9. Standby lamp: This lamp goes on when the unit is powered and
awaiting a command from the remote control.
10. Temperature and moisture sensor: If the remote control sensor is
not used the indoor unit sensor is activated, which registers the room
temperature and humidity and controls the indoor unit accordingly.
■ Remove the cover from the back of the remote control and check that
the six microswitches have been set as in the figure below:
Microswitch
The remote control can also be controlled by wire. For more information
see the installer manual.
NOTE
The remote control is set with default code 1 and does not usually have
to be changed.
If more than one unit is installed in the same room, code the units 1 - 4
with the remote control (see the procedure in the installer manual).
■ Insert two AAA 1.5 V-DC alkaline batteries and follow the polarity indic-
ated on the remote control. The time indicator on the display flashes.
■ Press the ST button and set the time. The remote control is now ready
for use.
Removing batteries
■ Remove the cover.
■ Slide the battery towards the negative terminal and
pull it out from the positive terminal’s side (as shown
in the figure).
■ Remove the other battery in the same way.
H Display
Function selector
B
I On/Off button
Temperature C Sensor selector
Air deflector D
J iFEEL
TiO 2-Air
Fan speed E K cleaner/Menu
L High power function
Night program/
energy saving F
M Timer and
time settings
A Temperature sensor
A sensor inside the remote control that reads off the room temperature.
B Function selector
Change the climate unit's function using these buttons.
C Temperature
The temperature buttons are used to increase/reduce the temperature.
D Air deflector
Use the air deflector to adjust the air distribution.
G IR transmitter
The IR transmitters transmit the command to the climate unit's receiver.
H Display
The display shows operating information when the remote control is
on.
I On/Off button
Starts or stop the climate unit.
18 11
17
16 15 14 13 12
1 Automatic operating mode selection
9 Temperature
19 Night reduction
PUSH
PUSH
Function selector
If the remote control does not work or is missing, use the function selector
as follows:
If you want to start the climate unit, press the function selector to select
the desired mode. Press once to activate cooling mode, twice to activate
heating mode and three times to switch off the unit, etc.
COOLING
KYLA
OFF
OFF VÄRME
HEAT
NOTE
The climate unit starts with the fan at HIGH speed. The temperature is
set to 25 °C for cooling mode and to 21 °C for heating.
1.
Press button until the symbol for cooling ( ) appears on the
display.
2. Press the +/- button (temperature selection) to set the desired temper-
ature (the setting range can be set between 10 °C and 32 °C).
NOTE
After the heating function is activated, the fan stops. This is because the
”Prevention of cold air” function is active and activates the fan's normal
function, only after the indoor unit's heat exchanger is sufficiently warm.
During this period the function lamp stays lit (red lamp).
NOTE
The climate unit changes function mode (from heating to cooling or
vice versa) when one of the following occurs:
■ ZONE A: changes if the temperature varies by at least 3 °C from the
value set on the remote control.
■ ZONE B: changes if the temperature varies by at least 1 °C from the
value set on the remote control one hour after the compressor has
stopped.
■ ZONE C: never changes if the temperature does not vary by more than
1 °C in relation to the value set in the remote control.
DEHU-
COOL-
AUTO HEAT MIDIFY- FAN
ING
ING
AUTO - - - - -
HEAT - OK - - OK
Sub-
DEHU-
sequent
MIDIFY- - - OK OK OK
indoor
ING
units
COOLING - - OK OK OK
FAN - OK OK OK OK
■ When the room temperature is above the set value the heat pump
works automatically to dehumidify as effectively as possible.
■ When the room temperature is below the set value, the heat pump
still works at low power to continue dehumidification and can reduce
the room temperature in small spaces to 10 °C.
NOTE
■ Use the dehumidification function to reduce the air humidity in the
room.
■ When the room temperature reaches the set value, the climate unit
repeats on and off cycles in automatic mode.
■ In dehumidifying mode the fan speed is set automatically.
High power-program
When this option is active, the fan speed is set automatically and the cli-
mate unit works at full cooling or heating power. High Power is active
until this function is switched off using the HIGH POWER button.
NOTE
In HIGH POWER mode, the temperature of the premises may not corres-
pond with the set temperature.
In the remote control there is a iFEEL sensor that makes it possible to adjust
the temperature based on where in the room the remote control is located,
for optimum comfort. The iFEEL function works via signal transfer from
the remote control to the indoor module, via two transmitters with IR
LEDs. The LEDs have a large scatter angle, which gives good room coverage.
Therefore, the remote control seldom needs pointing directly at the indoor
module, which is usually the case with remote controls, e.g. TVs and con-
sumer electronic products. However, the IR signal can be interrupted or
partially absorbed by different environmental factors, e.g.:
■ fluorescent lighting
■ sunlight
■ high humidity
■ IR generated heat sources
■ presence of many people or animals
■ certain building, interior and furniture material
■ size and shape of structures and objects in the environment
■ reflection and/or partial absorption of the IR signal
Manual mode
To manually regulate the fan speed, press the button and select the
desired speed:
PUSH
PUSH
Caution
If the installation is in automatic operating mode with both fans activated
the lower fan works most when heating and the upper fan when cooling.
1 1
2
3 3
4 4
5
6
6
NOTE
■ The air deflector closes automatically when the system is switched off.
■ When the system starts in heating mode, the fan stops and the air
deflector is in position 4 (if it is set to automatic oscillation) until the
system starts to heat up. When the air is heated, the position and
speed of the air deflector changes according to the settings specified
on the remote control.
NOTE
After the timer has been set, press the ST button to check the set on/off
time (ON/OFF).
Timer 1 hour
This function activates the climate unit for one hour, according to the set
conditions and then switches it off, regardless of whether the climate unit
was on or off before.
Actions for setting the timer
■
Press the button four times. The display shows the
symbol for TIMER 1 HOUR.
Air filter
Front cover
1. Press the "Push" markings at the top of the front cover and fold it out.
2. Unhook the filter and clean it.
NOTE
This filter does not ventilate the room air and does not remove dangerous
gases or vapour. If gas or oil heating equipment is used, doors or win-
dows must be regularly opened.
1 2
Check:
■ That the filter is always clean. A dirty filter reduces the air exchange and
reduces the unit's capacity.
■ That doors and windows are closed to prevent non-conditioned air from
entering.
NOTE
Work behind covers secured by screws may only be carried out by, or
under the supervision of, a qualified installation engineer.
Caution
You need the product's (14 digit) serial number for servicing and support.
Troubleshooting
If the climate unit does not work normally, perform the following checks,
before contacting the installer.
The start button is set to "OFF". Press the start button "ON/OFF".
Too high a temperature (further heat source or Remove or switch off other heat sources.
too many people in the room).
The air flow is blocked by external object. Remove blockages to resume correct air circula-
tion.
Too high a temperature set on remote control. Change the set temperature on the remote
control.
During the function the plastic parts expand as Situation that must be deemed normal. The
the temperature varies, which causes the un- clicking noise disappears when the temperature
pleasant noise. stabilises.
Key to symbols
The LED does not come on
The LED lights continuously
The LED flashes
Automatic diagnosis
LED lamps Cause/action
OPERATION TIMER STANDBY ■ The unit has not been addressed for the
multisplit system, allocate the unit an address
with the remote control (see the installer
manual).
■ The operating mode selected does not corres-
pond with the one that is active in the multisplit
system (heating mode is selected when the rest
of the system is in cooling mode or vice versa).
Change to the operating mode that is active in
the multisplit system.
If the fault persists after the above steps, contact
the installer.
37 4254 079 02
NIBE AB Sweden
Hannabadsvägen 5
Box 14
SE-285 21 Markaryd
info@nibe.se
www.nibe.eu