Você está na página 1de 18

Substation Automation New Configuration &

and Station Monitoring Tool


Protection
C
CAP 540 Ver.1.3
E
BUU: PTUA-R Training
© ABB Bangalore
1
CAP 540 basic package

CAP
CAP540
540
Parameter
ParameterSetting
Setting

Navigator
Navigator Disturbance
DisturbanceUpload
Upload

Disturbance
DisturbanceEvaluation
Evaluation
BUU: PTUA-R Training
© ABB Bangalore
2
CAP 540 full package with options

CAP
CAP540
540
Parameter
ParameterSetting
Setting

Navigator Disturbance
DisturbanceUpload
Upload
Navigator
Disturbance
DisturbanceEvaluation
Evaluation

Configuration
Configuration Option
Option

Remote
RemoteConnection
Connection Option
Option

Setting
SettingVisualisation Tool Option
VisualisationTool Option
BUU: PTUA-R Training
© ABB Bangalore
3
General about CAP 540 – full package

CAP
CAP540
540 CAP 540 is the navigator,
and from here it is possible
to navigate to the tools for:
Navigator
Navigator

- Parameter setting
- Disturbance upload
- Disturbance evaluation
- Configuration as option
- Remote connection as option
- Setting Visualisation as option
BUU: PTUA-R Training
© ABB Bangalore
4
Parameter Setting

Functions in REx 5xx


terminals can be
Parameter individually set in order to
ParameterSetting
Setting
perform the desired
selectivity or functionality
BUU: PTUA-R Training
© ABB Bangalore
5
Disturbance Handling
Disturbance files are stored
in the terminals
The list of disturbances
available in the terminal has
to be uploaded
The disturbances can then
Disturbance
DisturbanceUpload
Upload be collected one by one or
all at once
Disturbance
DisturbanceEvaluation
Evaluation
It is possible to retrieve the
disturbance recorder data as
sampled waveforms and
digital signals
This data can be evaluated
BUU: PTUA-R Training

by means of the evaluation


© ABB Bangalore

tool REVAL
6
Configuration

Functions represented by function


blocks and logic elements, timers,
Configuration
Configuration flip-flops etc. installed in REx 5xx
terminals, can be interconnected
in order to perform the desired
functionality
This type of job is called
CONFIGURATION, and it is
comparable to the wiring between
different units in one or several
cubicles
The configuration tool itself is
named CAP 531 version 1.6
BUU: PTUA-R Training
© ABB Bangalore
7
Remote connection

Remote Remote connection by


RemoteConnection
Connection
modem
Modem settings per station
List of suggested default
settings for a range of
modems
Enables remote Parameter
setting, Configuration and
disturbance upload
BUU: PTUA-R Training
© ABB Bangalore
8
Remote connection

Remote
RemoteConnection
Connection

Possibility to forward
disturbance files to ftp-site
Requires TCP/IP connection
BUU: PTUA-R Training
© ABB Bangalore
9
Setting Visualisation
Setting
SettingVisualisation
VisualisationTool
Tool
BUU: PTUA-R Training
© ABB Bangalore
10
CAP 540 – Full package with options

CAP
CAP540
540 PST
Parameter
ParameterSetting
Setting DISTURBANCE
UPLOAD
Disturbance
DisturbanceUpload
Upload
Navigator

REVAL
Navigator

Disturbance
DisturbanceEvaluation
Evaluation
CAP 531 AS OPTION
Configuration
Configuration Option
Option
REMOTE CONN.
Remote AS OPTION
RemoteConnection
Connection Option
Option
SETTING VISUL.
Setting
SettingVisualisation Tool Option
VisualisationTool Option AS OPTION
BUU: PTUA-R Training
© ABB Bangalore
11
© ABB Bangalore
BUU: PTUA-R Training
12
General about CAP 540
© ABB Bangalore
BUU: PTUA-R Training
13
CAP 540 – Architecture
© ABB Bangalore
BUU: PTUA-R Training
14
Support For Different Windows OS
General about CAP 540

Minimum PC requirements:
Pentium Processor
233 MHz or higher
128 MB RAM or more available
500 MB or more disk space available
VGA compatible monitor, min resolution 800 x 660,
256 colors
CD-ROM drive for installation
BUU: PTUA-R Training
© ABB Bangalore
15
Where and how can CAP 540 be used?

CAP 540 can be used both locally in the station


via SPA – direct or loop, and from remote via a
modem link
Please see the following CAP 540 architecture
and three typical system configurations with
SMS
BUU: PTUA-R Training
© ABB Bangalore
16
CAP 540 – Additional Built-in Programs

REx 5xx Terminal Internal-Clock


Synchronization via SPA Protocol
Time Scheduler (i.e. periodical
retrieval of stored disturbances)
RCALC Toll for Distance Relay
Setting Assistance
Disturbance File Type Converter
(COMTRADE, REVAL, EVE)
Communication Port Linker
(SPA) Terminal Emulator
RESDA Disturbance Analysis
BUU: PTUA-R Training
© ABB Bangalore
17
Summary - CAP 540

Basic package – found at


www.abb.com/substationautomation
Full package with optional configu-
ration,remote connection and setting
visualisation tool.
High functionality
User friendliness
Various Operating systems
Low PC requirements
Documentation function
On-line function
Extensive documentation of the tool
Excellent remote functionality
BUU: PTUA-R Training
© ABB Bangalore
18

Você também pode gostar