Generator set data sheet

Model: C900 D6B


Frequency: 60
Fuel type: Diesel

Spec sheet: SS15-CPGK


Noise data sheet (open/enclosed): MSP-2101
Airflow data sheet: MCP-1101

Standby Prime
Fuel consumption kW (kVA) kW (kVA)
Ratings 900 (1125) 810 (1013)
Load 1/4 1/2 3/4 Full 1/4 1/2 3/4 Full
US gph 25 34 45 60 14 27 47 54
L/hr 95 128 170 227 53 102 178 204

Standby Rating Prime Rating


Engine
Engine manufacturer Cummins
Engine model KTA38-G14
Configuration Cast iron, 60º V12 cylinder
Aspiration Turbocharged and after-cooled
Gross engine power output, kWm 1112 1007
BMEP at set rated load, kPa 1965 1779
Bore, mm 159
Stroke, mm 159
Rated speed, rpm 1800
Piston speed, m/s 9.5
Compression ratio 13.9:1
Lube oil capacity, L 161
Overspeed limit, rpm 2100 ±50
Regenerative power, kW 127
Governor type Electronic
Starting voltage 24 Volts DC

Fuel flow
Maximum fuel flow, L/hr 507
Maximum fuel inlet restriction, mm Hg 102
Maximum fuel inlet temperature, °C 61

©2016 | Cummins Power Generation Inc. | All rights reserved | Specifications subject to change without notice | Cummins Power Generation and Cummins are registered trademarks of Cummins Inc.
PowerCommand and “Our energy working for you.” are trademarks of Cummins Power Generation. Other company, product, or service names may be trademarks or service marks of others.
EMERD-6069a-EN (12/16)
Standby Rating Prime Rating
Air
Combustion air, m3/min 86.10 81.54
Maximum air cleaner restriction, kPa 6.2

Exhaust
Exhaust gas flow at set rated load, m3/min 238.0 218.4
Exhaust gas temperature, °C 524 499
Maximum exhaust back pressure, kPa 10.1

Standard set-mounted radiator cooling


Ambient design, °C 40
Fan load, kW m 33.8
Coolant capacity (with radiator), L 275
Cooling system air flow, m3/sec @ 12.7 mmH2O 17.7
Total heat rejection, Btu/min 38740 35100
Maximum cooling air flow static restriction mm H2O 25.4

Optional set-mounted radiator cooling


Ambient design, °C 50
Fan load, kW m 45.59
Coolant capacity (with radiator), L 275
Cooling system air flow, m3/sec @ 12.7 mmH2O RTF
Total heat rejection, Btu/min 48015 43520
Maximum cooling air flow static restriction mm H2O RTF

Weights* Open Enclosed


Unit dry weight kgs 7990 RTF
Unit wet weight kgs 8380 RTF
* Weights represent a set with standard features. See outline drawing for weights of other configurations.

Dimensions Length Width Height


Standard open set dimensions mm 4470 1785 2229
Enclosed set standard dimensions mm RTF RTF RTF

Genset outline
Open set

Outlines are for illustrative purposes only. Please refer to the genset outline drawing for an exact representation of this model.

©2016 | Cummins Power Generation Inc. | All rights reserved | Specifications subject to change without notice | Cummins Power Generation and Cummins are registered trademarks of Cummins Inc.
PowerCommand and “Our energy working for you.” are trademarks of Cummins Power Generation. Other company, product, or service names may be trademarks or service marks of others.
EMERD-6069a-EN (12/16)
Alternator data

Connection Temp rise ºC Duty Alternator Voltage


Wye, 3-phase 125/150 C S/P HC6J 380-480V

Ratings definitions
Emergency standby power Limited-time running Base load (continuous)
(ESP): power (LTP): Prime power (PRP): power (COP):

Applicable for supplying Applicable for supplying Applicable for supplying Applicable for supplying
power to varying electrical power to a constant power to varying electrical power continuously to a
load for the duration of electrical load for limited load for unlimited hours. constant electrical load
power interruption of a hours. Limited Time Prime Power (PRP) is in for unlimited hours.
reliable utility source. Running Power (LTP) is in accordance with Continuous Power (COP)
Emergency Standby Power accordance with ISO 8528. ISO 8528. Ten percent is in accordance with ISO
(ESP) is in accordance with overload capability is 8528, ISO 3046,
ISO 8528. Fuel Stop power available in accordance AS 2789, DIN 6271 and
in accordance with ISO with ISO 3046, AS 2789, BS 5514.
3046, AS 2789, DIN 6271 DIN 6271 and
and BS 5514. BS 5514.

Formulas for calculating full load currents:


Three phase output Single phase output
kW x 1000 kW x SinglePhas eFactor x 1000
Voltage x 1.73 x 0.8 Voltage

See your distributor for more information.


Cummins Power Generation
Manston Park, Columbus Avenue
Manston, Ramsgate
Kent CT12 5BF, UK
Telephone: +44 (0) 1843 255000
Fax +44 (0) 1843 255902
E-mail: cpg.uk@cummins.com
Web: power.cummins.com

©2016 | Cummins Power Generation Inc. | All rights reserved | Specifications subject to change without notice | Cummins Power Generation and Cummins are registered trademarks of Cummins Inc.
PowerCommand and “Our energy working for you.” are trademarks of Cummins Power Generation. Other company, product, or service names may be trademarks or service marks of others.
EMERD-6069a-EN (12/16)

Você também pode gostar