Dell Compellent Enterprise Manager

2014 R2

Installation Guide
Enterprise Manager 2014 R2 Installation Guide
Document Number: 680‐028‐018

Revision Date Description


A April 2014 Initial release to support Enterprise Manager 2014 R2.

Notes, Cautions, and Warnings


Note: Indicates important information that helps you complete a procedure.

Caution: Indicates either potential damage to hardware or loss of data and tells you how to avoid 
the problem.

Warning: Indicates that failure to follow directions could result in property damage, personal 
injury, or death.

Copyright Notice and Trademarks


Copyright © 2014 Dell Inc. All rights reserved. This product is protected by U.S. and international 
copyright and intellectual property laws. Dell™ and the Dell logo are trademarks of Dell Inc. in the United 
States and/or other jurisdictions. All other marks and names mentioned herein may be trademarks of their 
respective companies.

Contacting Dell Technical Support Services


For technical support, go to support.dell.com/compellent/.
Contents

Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Related Publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Enterprise Manager Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Storage Center Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi
FluidFS Cluster Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi
Fluid Cache Cluster Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii

1 Introduction to Enterprise Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1


Enterprise Manager Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Management Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Software and Hardware Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Data Collector Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Client Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Server Agent Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Default Ports Used by Enterprise Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Data Collector Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Client Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Server Agent Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
IPv6 Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

2 Planning and Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9


Choose a Data Storage Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Gather Required Installation Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
License Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Database Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Dell Compellent iii


Contents

Prepare the Database . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10


Prepare a Microsoft SQL Server Database . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Prepare a MySQL Database . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Install the Java Runtime Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

3 Installing and Configuring the Data Collector . . . . . . . . . . . . . . . . . . . 13


Install the Data Collector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Complete the Data Collector Setup Wizard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Configure the Data Collector to Use a Microsoft SQL Server Database . . . . . . . . . . . . . . . 14
Configure the Data Collector to Use a MySQL Database . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Configure the Data Collector to Use the Embedded Database . . . . . . . . . . . . . . . . . . . . . . . 23

4 Installing and Configuring the Enterprise Manager Client . . . . . . . . 27


Install the Enterprise Manager Client . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Use the Client to Connect to the Data Collector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Add Storage Centers to Enterprise Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Next Steps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

iv Enterprise Manager 2014 R2 Installation Guide


Preface

The preface introduces you to the Enterprise Manager documentation. It provides the purpose and 
audience of this document as well as a list of related publications.

Purpose
This guide describes how to install and configure Enterprise Manager components. For information about 
using Enterprise Manager to manage and monitor your Dell Compellent storage infrastructure, see the 
Enterprise Manager Administrator’s Guide.

Audience
Storage administrators make up the target audience for this document. The intended reader has a working 
knowledge of storage and networking concepts.

Related Publications
The following documentation is available for Dell Compellent storage components managed using 
Enterprise Manager.

Enterprise Manager Documents


The following documentation is available for Enterprise Manager.
 Dell Compellent Enterprise Manager Installation Guide
Contains installation and setup information.
 Dell Compellent Enterprise Manager Administrator’s Guide
Contains in‐depth feature configuration and usage information.
 Dell Compellent Enterprise Manager Release Notes 
Provides information about Enterprise Manager releases, including new features and enhancements, 
open issues, and resolved issues. 
 Dell Compellent Enterprise Manager Online Help
Provides context‐sensitive help for the Client, Data Collector Manager, and Server Agent.

Dell Compellent v
Storage Center Documents
The following documentation is available for Storage Centers managed using Enterprise Manager.
 Storage Center Release Notes 
Contains information about features and open and resolved issues for a particular product version.
 Storage Center Deployment Guide 
Provides cabling instructions for Storage Center controllers, switches, and enclosures and provides 
instructions for configuring a new Dell Compellent Storage Center using the System Manager Startup 
wizard.
 Storage Center System Manager Administrator’s Guide 
Describes the Storage Center System Manager software that manages an individual Storage Center.
 Storage Center Software Update Guide
Describes how to upgrade Storage Center software from an earlier version to the current version.
 Storage Center Maintenance CD Instructions
Describes how to install Storage Center software on Storage Center controllers. Installing Storage Center 
software using the Storage Center Maintenance CD is intended for use only by sites that cannot update 
Storage Center using the standard update options available through the Storage Center System 
Manager.
 Storage Center Command Utility Reference Guide
Provides instructions for using the Storage Center Command Utility. The Command Utility provides a 
command‐line interface (CLI) to enable management of Storage Center functionality on Windows, 
Linux, Solaris, and AIX platforms.
 Storage Center Command Set for Windows PowerShell 
Provides instructions for getting started with Windows PowerShell cmdlets and scripting objects that 
interact with the Storage Center via the PowerShell interactive shell, scripts, and PowerShell hosting 
applications. Help for individual cmdlets is available online.

FluidFS Cluster Documents


The following documentation is available for FluidFS clusters managed using Enterprise Manager.
 Dell Compellent FluidFS Version 3.0 FS8600 Appliance Pre‐Deployment Requirements 
Provides a checklist that assists in preparing to deploy an FS8600 appliance prior to a Dell Compellent 
installer or certified business partner arriving on‐site to perform an FS8600 appliance installation. The 
target audience for this document is Dell Compellent installers and certified business partners who 
perform FS8600 appliance installations.
 Dell Compellent FluidFS Version 3.0 FS8600 Appliance Deployment Guide 
Provides information about deploying an FS8600 appliance, including cabling the appliance to the 
Storage Center(s) and the network, and deploying the appliance using the Enterprise Manager software. 
The target audience for this document is Dell Compellent installers and certified business partners who 
perform FS8600 appliance installations.
 Dell Compellent FluidFS Version 3.0 FS8600 Appliance Administrator’s Guide 
Provides information about using the Enterprise Manager software to manage FS8600 appliances, and 
provides information about FS8600 appliance monitoring and troubleshooting. The target audience for 
this document is customers.
 Dell Compellent FluidFS Version 3.0 FS8600 Appliance CLI Reference Guide 
Provides information about the FS8600 appliance command line interface. The target audience for this 
document is customers.

vi Enterprise Manager 2014 R2 Installation Guide


 Dell Compellent FS8600 Appliance FluidFS Version 3.0 Software Update Guide 
Provides information about upgrading the FluidFS software from version 2.0 to 3.0. The target audience 
for this document is customers.
 Dell Compellent FluidFS Version 3.0 FS8600 Appliance Release Notes 
Provides information about FluidFS releases, including new features and enhancements, open issues, 
and resolved issues. The target audience for this document is customers.
 Dell Compellent FS8600 Appliance Service Guide 
Provides information about FS8600 appliance hardware, system component replacement, and system 
troubleshooting. The target audience for this document is Dell Compellent installers and certified 
business partners who perform FS8600 appliance hardware service.
 Dell NAS Appliance SFP+ Replacement Procedure 
Provides information about replacing SFP+ transceivers on an inactive system. The target audience for 
this document is Dell Compellent installers and certified business partners who perform FS8600 
appliance hardware service.
 Dell Compellent FluidFS Version 3.0 FS8600 Appliance 1Gb to 10Gb Upgrade Procedure
Provides information about upgrading a Fibre Channel FS8600 appliance from 1Gb Ethernet client 
connectivity to 10Gb Ethernet client connectivity. The target audience for this document is Dell 
Compellent installers and certified business partners who perform FS8600 appliance hardware service.

Fluid Cache Cluster Documents


The following documentation is available for Fluid Cache clusters managed using Enterprise Manager.
 Dell Fluid Cache For SAN Deployment Guide for VMware ESXi Systems 
Describes the process of deploying Fluid Cache for SAN, including system requirements, installation 
procedures, and troubleshooting. Includes additional procedures specific to configuring Fluid Cache 
clusters in VMware environments.
 Dell Fluid Cache For SAN Deployment Guide for Linux Systems 
Describes the process of deploying Fluid Cache for SAN, including system requirements, installation 
procedures, and troubleshooting. Includes requirements specific to supported Linux distributions.
 Dell Fluid Cache for SAN Release Notes 
Documents known issues and lists the most current software and hardware requirements.

Dell Compellent vii


viii Enterprise Manager 2014 R2 Installation Guide
1 Introduction to Enterprise Manager

Enterprise Manager allows you to monitor, manage, and analyze Storage Centers and 
FluidFS clusters from a centralized management console. The Enterprise Manager Data 
Collector stores data and alerts it gathers from Storage Centers and FluidFS clusters in an 
external database or an embedded database. Enterprise Manager Clients connect to the 
Data Collector to perform monitoring and administrative tasks.
This guide describes how to install and configure required Enterprise Manager 
components. For information about installing optional Enterprise Manager components, 
see the Enterprise Manager Administrator’s Guide.

Contents
Enterprise Manager Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   2
Management Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   2
Software and Hardware Requirements  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   3
Default Ports Used by Enterprise Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   5
IPv6 Support  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   7

Dell Compellent 1
Chapter 1 Introduction to Enterprise Manager

Enterprise Manager Components


Enterprise Manager consists of the following components:

Required/
Component Description Optional Setup Documentation
Primary Data  Service that gathers reporting data  Required Enterprise Manager 
Collector and alerts from Storage Centers Installation Guide

Client Windows‐based application that  Required Enterprise Manager 


connects to the Data Collector to  Installation Guide
provide a centralized management 
console for one or more Storage 
Centers

Remote Data  Data Collector that is connected to the  Optional Enterprise Manager 


Collector primary Data Collector and can be  Administrator’s Guide
used to activate a disaster recovery site 
if the primary Data Collector becomes 
unavailable

Server Agent Service for Windows that allows  Optional Enterprise Manager 


Enterprise Manager to free volume  Administrator’s Guide
storage space from expired Replays 
that would otherwise remain locked 
by Windows

Management Compatibility
Enterprise Manager manages Dell Compellent products and also provides management 
integration for Microsoft and VMware products.
Enterprise Manager is compatible with the products listed in the following table.

Product Version
Dell Compellent Storage Center Storage Center OS versions 5.5–6.5
Note: Version 6.4.1 is not supported.

Dell Compellent FS8600 FluidFS versions 2.0–3.0

Fluid Cache for SAN Version 2.0.0

Microsoft System Center Virtual  Versions 2012, 2012 SP1, and 2012 R2
Machine Manager (SCVMM)

VMware vCenter Site Recovery  Versions 5.0, 5.1, and 5.5
Manager (SRM) Note: Compatibility is provided by the Dell Compellent 
Storage Replication Adapter (SRA) 6.2.2.

2 Enterprise Manager 2014 R2 Installation Guide


Software and Hardware Requirements

Software and Hardware Requirements


The following sections list the requirements for the Data Collector, Client, and Server 
Agent.

Data Collector Requirements


The following table lists the Enterprise Manager Data Collector requirements.

Component Requirements
Operating system Any of the following 64‐bit operating systems with the latest service packs:
• Windows Server 2003
• Windows Server 2008
• Windows Server 2008 R2
• Windows Server 2012
• Windows Server 2012 R2
Note: 32‐bit operating systems are not supported, and Windows Server Core is 
not supported.

CPU 64‐bit (x64) microprocessor with two or more cores

RAM At least 4 GB; 8 GB if using the Dell Compellent Site Recovery Adapter (SRA) 
for VMware vCenter Site Recovery Manager

Disk space At least 20 GB; additional space is required to manage FluidFS cluster software 
upgrades

Software All of the following:
• Microsoft .NET Framework 2.0 and Microsoft .NET Framework 3.5
• Windows PowerShell 2.0 or higher (for SMI‐S only)
• 64‐bit Java Runtime Environment (JRE) 1.7 Update 45 or later (JRE 1.8 is not 
supported)

Web browser Any of the following web browsers:
• Internet Explorer
• Firefox
• Safari
• Google Chrome
Note: Other web browsers may work but are not officially supported.

Database One of the following:
• Microsoft SQL Server 2008
• Microsoft SQL Server 2008 Express (limited to 4 GB)
• Microsoft SQL Server 2008 R2
• Microsoft SQL Server 2008 R2 Express (limited to 10 GB)
• Microsoft SQL Server 2012
• Microsoft SQL Server 2012 Express (limited to 10 GB)
• MySQL 5.1
• MySQL 5.5
• Embedded database on the file system (maximum of 30 days or 2 GB)
Note: The database used for storing data can be changed after installation.

Dell Compellent 3
Chapter 1 Introduction to Enterprise Manager

Client Requirements
The following table lists the requirements for the Enterprise Manager Client.

Component Requirements
Operating system Any of the following 32‐bit or 64‐bit operating systems (with the latest service 
packs):
• Windows Vista
• Windows 7
• Windows 8
• Windows Server 2003
• Windows Server 2008
• Windows Server 2008 R2
• Windows Server 2012
• Windows Server 2012 R2
Note: Windows Server Core is not supported.

CPU  32‐bit (x86) or 64‐bit (x64) microprocessor

Software All of the following:
• Java Runtime Environment (JRE) 1.7 Update 45 or later
– 32‐bit JRE is required on 32‐bit operating systems, 64‐bit JRE is required 
on 64‐bit operating systems
– JRE 1.8 is not supported
• Microsoft .NET Framework 2.0 (included with all supported operating 
systems)

Web browser Any of the following web browsers:
• Internet Explorer
• Firefox
• Safari
• Google Chrome
Note: Other web browsers may work but are not officially supported.

4 Enterprise Manager 2014 R2 Installation Guide


Default Ports Used by Enterprise Manager

Server Agent Requirements


The following table lists the requirements for the Enterprise Manager Server Agent for 
Windows‐based servers.

Component Requirements
Operating system Any of the following 32‐bit or 64‐bit operating systems (with the latest service 
packs):
• Windows Server 2003
• Windows Server 2008 (full installation only)
• Windows Server 2008 R2 (full or core installation)
• Windows Storage Server 2008 R2
• Windows Server 2012 (full or core installation)
• Windows Server 2012 R2 (full or core installation)

CPU  32‐bit (x86) or 64‐bit (x64) microprocessor

Software • Microsoft .NET Framework 2.0
• Microsoft Windows Installer 4.5 (included with Windows Server 2008 and 
later)

Default Ports Used by Enterprise Manager


The Enterprise Manager components use network connections to communicate with each 
other and with other network resources. The following tables list the default network ports 
used by the Data Collector, Server Agent, and Client. Many of the ports are configurable.

Note: Some ports might not be needed for your configuration. For details, see the 
Purpose column in each table.

Data Collector Ports


The following table lists the ports used by the Enterprise Manager Data Collector.

Port Protocol Name Purpose


Inbound Ports
514 UDP syslog Receiving logs forwarded from Storage Centers

3033 TCP Web Server Port Receiving:


• Communication from all clients, including the 
Enterprise Manager Client and Storage Replication 
Adapter (SRA) 6.2.2
• Alerts from FluidFS clusters
• Alerts from Fluid Cache clusters

8080 TCP Legacy Web Services  Receiving:


Port • Communication from Server Agents
• Alerts forwarded from Storage Centers

7342 TCP Legacy Client  • Communicating with the remote Data Collector


Listener Port • Providing automatic upgrade functionality for 
previous versions of the Enterprise Manager Client

Dell Compellent 5
Chapter 1 Introduction to Enterprise Manager

Port Protocol Name Purpose


5988 TCP SMI‐S over HTTP Receiving unencrypted SMI‐S communication

5989 TCP SMI‐S over HTTPS Receiving encrypted SMI‐S communication

Outbound Ports
25 TCP SMTP Sending email notifications

443 TCP SSL • Communicating with managed Storage Centers and 


managed zNAS servers
• Sending Phone Home data
• Activating the license

514 UDP syslog Forwarding Storage Center logs to syslog servers

1433 TCP Microsoft SQL Server Connecting to an external Microsoft SQL Server 


database

3306 TCP MySQL Connecting to an external MySQL database


6774 TCP Fluid Cache Communicating with Fluid Cache servers

8080 TCP VMware SDK Communicating with VMware servers

27355 TCP Server Agent Socket  Communicating with Server Agents


Listening Port

35451 TCP FluidFS Communicating with managed FluidFS clusters

44421 TCP FluidFS diagnostics Retrieving diagnostics from managed FluidFS clusters

Client Ports
The following table lists the ports used by the Enterprise Manager Client.

Port Protocol Name Purpose


Outbound Ports
3033 TCP Web Server Port Communicating with the Data Collector

Server Agent Ports


The following table lists the ports used by the Enterprise Manager Server Agent.

Port Protocol Name Purpose


Inbound Ports
27355 TCP Server Agent Socket  Receiving communication from the Data Collector
Listening Port

Outbound Ports
8080 TCP Legacy Web Services  Communicating with the Data Collector
Port

6 Enterprise Manager 2014 R2 Installation Guide


IPv6 Support

IPv6 Support
The Data Collector can use IPv6 to accept connections from the Enterprise Manager Client 
and to communicate with managed Storage Centers.
To use IPv6, assign IPv6 addresses as described in the following table.

IPv6 Connection Requirements


Client to Data Collector • Client computer must have an IPv6 address.
• Data Collector server must have both an IPv4 and an IPv6 address.

Data Collector to Storage  • Data Collector server must have both an IPv4 and an IPv6 address.
Center • Storage Center must have both an IPv4 and an IPv6 address on the 
management interface.

Dell Compellent 7
Chapter 1 Introduction to Enterprise Manager

8 Enterprise Manager 2014 R2 Installation Guide


2 Planning and Preparation

Before you install Enterprise Manager, plan your configuration and install the required 
software.

Contents
Choose a Data Storage Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   9
Gather Required Installation Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   10
Prepare the Database  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   10
Install the Java Runtime Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   12

Choose a Data Storage Method


You can configure the Data Collector to store data in an external database or in an 
embedded database on the file system of the host server. 
Choose the option that is most appropriate for your environment:
 External database: If you decide to use an external database, select the supported 
database type that best suits your needs. See Data Collector Requirements on page 3 for 
a list of supported database types.
Enterprise Manager uses a database administrator account to create a database user 
named compmsauser and a database named compmsadb, which uses a custom schema.
 Embedded database: If you choose to use the embedded database, the Data Collector 
can only retain 30 days worth of data, and the database size cannot exceed 2 GB.

Note: The embedded database is not recommended for a production 
environment.

Dell Compellent 9
Chapter 2 Planning and Preparation

Gather Required Installation Information


Before installing Enterprise Manager components, print this page and record the following 
information.

License Information
Record the Enterprise Manager product key below. If you do not have a product key, 
contact Dell Technical Support Services for assistance.

Item Write down your information


Enterprise Manager Product Key

Database Information
If you plan to use an SQL database, record database information that is needed for 
installation.

Item Write down your information


Database version 

Name of server on which the database 
resides

Database server port

Database user name For security reasons, only record the database 
username in a secure location.

Database password For security reasons, only record the database 
password in a secure location.

Prepare the Database


If you plan to use an external database, prepare the database by performing the task that 
corresponds to your database type:
 Prepare a Microsoft SQL Server Database on page 10
 Prepare a MySQL Database on page 11

Note: If you want to store Data Collector data in the embedded database, skip this 
step.

Prepare a Microsoft SQL Server Database


Set up the Microsoft SQL Server database or Microsoft SQL Server Express database for the 
Data Collector.
1 If necessary, install the database software.
2 Make sure you have the credentials for a database administrator account with 
privileges equivalent to the default sa account.
3 Configure the database for mixed mode authentication (SQL Server and Windows 
Authentication mode).
4 Start the SQL Server Configuration Manager application.

10 Enterprise Manager 2014 R2 Installation Guide


Prepare the Database

5 Set the TCP/IP ports.
a In the navigation pane, expand SQL Server Network Configuration.
b Click Protocols for MSSQLSERVER or Protocols for SQLEXPRESS.
c Right‐click TCP/IP and select Properties. The TCP/IP Properties dialog box 
appears.
d Click the IP Addresses tab.

e Under IPALL, make sure the TCP Port is set to a valid port number. The default TCP 
port for SQL Server is 1433.
f Click Apply and click OK to close the dialog box.
6 Enable TCP/IP protocol:
a In the navigation pane, click Protocols for MSSQLSERVER or Protocols for 
SQLEXPRESS.
b Right‐click TCP/IP and select Enable.
7 Restart SQL Server.
a In the navigation pane, click SQL Server Services.
b Right‐click SQL Server and select Restart.

Prepare a MySQL Database


Set up the database permissions for the Data Collector.
1 If necessary, install the database software.
2 Make sure that you have administrator rights from remote servers (preferably root 
user).
3 Make sure the database admin user has the global CREATE USER, RELOAD, and 
SELECT permissions, and has full permissions to the compmsadb database. 

Dell Compellent 11
Chapter 2 Planning and Preparation

Enter the following commands from the MySQL admin tool, where root is the name of 
the admin user:
grant create user, reload, select on *.* to 'root'@'%';
grant all privileges on compmsadb.* to 'root'@'%' with grant option;
flush privileges;

Install the Java Runtime Environment


The Enterprise Manager Data Collector and Enterprise Manager Client require the Java 
Runtime Environment (JRE). See Data Collector Requirements on page 3 for the JRE 
version requirement.
 Install the JRE on each computer that will host the Enterprise Manager Data Collector 
and/or the Enterprise Manager Client.
 For 64‐bit operating systems, install both the 32‐bit version and the 64‐bit version of the 
JRE.

12 Enterprise Manager 2014 R2 Installation Guide


3 Installing and Configuring the Data
Collector

Install the Data Collector and configure settings using the Setup Wizard.

Contents
Install the Data Collector  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   13
Complete the Data Collector Setup Wizard  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   13

Install the Data Collector


Install the Data Collector on a Windows server that has network connectivity to your 
Storage Centers.
Prerequisites
The tasks described in Chapter 2: Planning and Preparation, on page 9 must be complete.
Steps
1 Download the latest Enterprise Manager Data Collector software from the Knowledge 
Center by logging on to the customer or partner portal (from support.dell.com/
compellent).
2 Unzip and launch the Enterprise Manager Data Collector Setup file. The InstallShield 
Wizard appears.
3 Click Next. The License Agreement page appears. 
4 Read the license agreement and then click Yes to accept it. The Setup Status page 
appears and displays installation progress. When installation is complete, the 
InstallShield Wizard Complete page appears. 
5 Click Finish. The Enterprise Manager Data Collector Setup wizard appears.

Note: For user interface reference information, click Help.

Complete the Data Collector Setup Wizard


To configure the Data Collector, perform the task that corresponds to your preferred data 
storage method.
 Configure the Data Collector to Use a Microsoft SQL Server Database on page 14
 Configure the Data Collector to Use a MySQL Database on page 18
 Configure the Data Collector to Use the Embedded Database on page 23

Dell Compellent 13
Chapter 3 Installing and Configuring the Data Collector

Configure the Data Collector to Use a Microsoft SQL Server


Database
Perform this task if you want the Data Collector to store data in an external Microsoft SQL 
Server database.
1 Configure the first page of the Data Collector Setup wizard.

a Under Data Collector Type, select Configure as Primary Data Collector. 
b (Optional) Under Data Collector Service Information, modify the default Data 
Collector ports if one or more of the default ports are already in use.

Note: If a firewall is enabled on the host computer, make sure these ports are 
allowed inbound.

c In the Data Source Type drop‐down menu, select MS SQL Server 2008/2012.
d In the Service User Type drop‐down menu, select the type of Windows account 
under which the Data Collector will run.

Note: User accounts (local or domain) must be able to log in as a service and 
must have administrator privileges. 

e Click Next. The Activate Enterprise Manager License page appears.

2 Enter the license information.

14 Enterprise Manager 2014 R2 Installation Guide


Complete the Data Collector Setup Wizard

Note: The Data Collector can be used for 30 days without activation.

a Enter the Product Key provided by Dell Compellent. 
b Select the appropriate activation method:
 If the server that is hosting the Data Collector has Internet access, select Activate 
over Internet.
 If the server that is hosting the Data Collector does not have Internet access, select 
Activate over Email/Phone.
c If you are activating over email or telephone, contact Dell Technical Support Services 
to obtain the Confirmation Number. (See support.dell.com/compellent.)
d Click Next. The Data Source Properties page appears.

3 Specify the Microsoft SQL Server database information.
a In the Server field, enter the host name or IP address of the server on which the 
database is installed.
b In the Port field, enter the TCP port that was configured during the database
TCP/IP setup. The default port for Microsoft SQL Server is 1433.
c In the Username/Password fields, enter the username and password for a user 
defined in the database that has administrator rights to create databases and 
database users. The Data Collector uses this information to create a database user 
named compmsauser.
d (Optional) To specify a password for the compmsauser database user, select Use 
Custom Password, then type a password in the EM DB User Password field. If you 
do not specify a password, a 13‐character default password is used.
e Click Next. Enterprise Manager attempts to communicate with the database server.
 If a communication error appears, verify the database information, verify that 
Enterprise Manager has connectivity to the database server, and make sure that 
the database server allows remote connections.
 If a user creation error appears and the database server was previously used to 
store Enterprise Manager data, delete the database user named compmsauser 
and the database named compmsadb, and then try again.
 If Enterprise Manager is able to communicate with the database server, the 
SMI‐S Server Properties page appears.

Dell Compellent 15
Chapter 3 Installing and Configuring the Data Collector

4 (Optional) Configure SMI‐S Server Properties.
a To configure SMI‐S at this time, select Enabled, then configure the remaining 
properties.

Note: You can also configure SMI‐S after the Data Collector is installed and 
configured. For information on setting up and using SMI‐S, see the Dell 
Compellent Enterprise Manager Administrator’s Guide.

b Click Next. The Network Adaptor and Max Memory Settings page appears.

5 Select the network adapter and specify the memory limit for the Data Collector.
a If the server that hosts the Data Collector has multiple network adapters, select 
which adapter the Data Collector should use for communication.
 To select a network adapter automatically, select the Automatically Select 
Network Adapter check box.
 To manually select a network adapter, choose a network adapter from the drop‐
down menu.
b In the Max Memory Settings area, choose an option to specify the maximum 
amount of memory that can be used by the Data Collector. If the Data Collector 
manages many Storage Centers, increasing this limit can improve performance.

16 Enterprise Manager 2014 R2 Installation Guide


Complete the Data Collector Setup Wizard

Note: Dell Compellent recommends specifying a value that is less than total 
memory available to the Data Collector host server.

c Click Next. The Create Administrator User page appears.

6 Create an administrator user.
a Enter a user name, password, and password confirmation.

Note: Record the user name and password. You will need this information to 
log on to Enterprise Manager after installation is complete.

b Click Next. The Data Collector Service is started. After the Data Collector starts, the 
Finished setup page appears.

7 Record the URL for the Data Collector website, then click Finish. The Enterprise 
Manager Data Collector Setup wizard exits.

Dell Compellent 17
Chapter 3 Installing and Configuring the Data Collector

Configure the Data Collector to Use a MySQL Database


Perform this task if you want the Data Collector to store data in an external MySQL 
database.
1 Configure the first page of the Data Collector Setup wizard.

a Under Data Collector Type, select Configure as Primary Data Collector. 
b (Optional) Under Data Collector Service Information, modify the default Data 
Collector ports if one or more of the default ports are already in use.

Note: If a firewall is enabled on the host computer, make sure these ports are 
allowed inbound.

c In the Data Source Type drop‐down menu, select MySQL 5.1/5.5.
d In the Service User Type drop‐down menu, select the type of Windows account 
under which the Data Collector will run.

Note: User accounts (local or domain) must be able to log in as a service and 
must have administrator privileges.

e Click Next. The Manual Steps required dialog box appears. 

f Click No. The Data Collector Setup wizard exits.
2 Download and install the MySQL Connector/J JDBC driver. 
a In a web browser, go to dev.mysql.com/downloads/connector/j.
b Download the .tar or .zip MySQL Connector/J JDBC driver.
c Extract the driver.
d Change name of the mysql‐connector‐java‐<version>‐bin.jar file to mysql.jar.
e Replace the current mysql.jar file by copying mysql.jar file you downloaded to the 
following directory:
C:\Program Files (x86)\Compellent Technologies\Compellent Enterprise
Manager\msaservice\lib

18 Enterprise Manager 2014 R2 Installation Guide


Complete the Data Collector Setup Wizard

3 Start the Enterprise Manager Data Collector Manager application. The Enterprise 
Manager Data Collector Setup wizard appears.
4 In the Data Source Type drop‐down menu, select MySQL 5.1/5.5, then click Next. The 
Manual Steps required dialog box appears.
5 Click Yes. The Activate Enterprise Manager License page appears.

6 Enter the license information.

Note: The Data Collector can be used for 30 days without activation.

a Enter the Product Key provided by Dell Compellent. 
b Select the appropriate activation method:
 If the server that is hosting the Data Collector has Internet access, select Activate 
over Internet.
 If the server that is hosting the Data Collector does not have Internet access, select 
Activate over Email/Phone.
c If you are activating over email or telephone, contact Dell Technical Support Services 
to obtain the Confirmation Number. (See support.dell.com/compellent.)
d Click Next. The Data Source Properties page appears.

Dell Compellent 19
Chapter 3 Installing and Configuring the Data Collector

7 Specify the MySQL database information.
a In the Server field, enter the host name or IP address of the server on which the 
database is installed.
b In the Port field, enter the TCP port that was configured during the database 
TCP/IP setup. The default for MySQL is 3306.
c In the Username/Password fields, enter the username and password for a user 
defined in the database that has administrator rights to create databases and 
database users. The Data Collector uses this information to create a database user 
named compmsauser.
d (Optional) To specify a password for the compmsauser database user, select Use 
Custom Password, then type a password in the EM DB User Password field. If you 
do not specify a password, a 13‐character default password is used.
e Click Next. Enterprise Manager attempts to communicate with the database server.
 If a communication error appears, verify the database information, verify that 
Enterprise Manager has connectivity to the database server, and make sure that 
the database server allows remote connections.
 If a user creation error appears and the database server was previously used to 
store Enterprise Manager data, delete the database user named compmsauser 
and the database named compmsadb, and then try again.
 If Enterprise Manager is able to communicate with the database server, the 
SMI‐S Server Properties page appears.

8 (Optional) Configure SMI‐S Server Properties.
a To configure SMI‐S at this time, select Enabled, then configure the remaining 
properties.

Note: You can also configure SMI‐S after the Data Collector is installed and 
configured. For information on setting up and using SMI‐S, see the Dell 
Compellent Enterprise Manager Administrator’s Guide.

20 Enterprise Manager 2014 R2 Installation Guide


Complete the Data Collector Setup Wizard

b Click Next. The Network Adaptor and Max Memory Settings page appears.

9 Select the network adapter and specify the memory limit for the Data Collector.
a If the server that hosts the Data Collector has multiple network adapters, select 
which adapter the Data Collector should use for communication.
 To select a network adapter automatically, select the Automatically Select 
Network Adapter check box.
 To manually select a network adapter, choose a network adapter from the drop‐
down menu.
b In the Max Memory Settings area, choose an option to specify the maximum 
amount of memory that can be used by the Data Collector. If the Data Collector 
manages many Storage Centers, increasing this limit can improve performance.

Note: Dell Compellent recommends specifying a value that is less than total 
memory available to the Data Collector host server.

c Click Next. The Create Administrator User page appears.

10 Create an administrator user.
a Enter a user name, password, and password confirmation.

Note: Record the user name and password. You will need this information to 
log on to Enterprise Manager after installation is complete.

Dell Compellent 21
Chapter 3 Installing and Configuring the Data Collector

b Click Next. The Data Collector Service is started. After the Data Collector starts, the 
Finished setup page appears.

11 Record the URL for the Data Collector website, then click Finish. The Enterprise 
Manager Data Collector Setup wizard exits.

22 Enterprise Manager 2014 R2 Installation Guide


Complete the Data Collector Setup Wizard

Configure the Data Collector to Use the Embedded Database


Perform this task if you want the Data Collector to store data in an embedded database on 
the local file system.

Note: The embedded database is not recommended for a production environment.

1 Configure the first page of the Data Collector Setup wizard.

a Under Data Collector Type, select Configure as Primary Data Collector. 
b (Optional) Under Data Collector Service Information, modify the default Data 
Collector ports if one or more of the default ports are already in use.

Note: If a firewall is enabled on the host computer, make sure inbound 
connections are allowed on these ports.

c In the Data Source Type drop‐down menu, select File System.
d In the Service User Type drop‐down menu, select the type of Windows account 
under which the Data Collector will run.

Note: User accounts (local or domain) must be able to log in as a service and 
must have administrator privileges.

e Click Next. A confirmation dialog box appears.

Dell Compellent 23
Chapter 3 Installing and Configuring the Data Collector

f Click Yes. The Activate Enterprise Manager License page appears.

2 Enter the license information.

Note: The Data Collector can be used for 30 days without activation.

a Enter the Product Key provided by Dell Compellent. 
b Select the appropriate activation method:
 If the server that is hosting the Data Collector has Internet access, select Activate 
over Internet.
 If the server that is hosting the Data Collector does not have Internet access, select 
Activate over Email/Phone.
c If you are activating over email or telephone, contact Dell Technical Support Services 
to obtain the Confirmation Number. (See support.dell.com/compellent.)
d Click Next. The Data Source Properties page appears.

3 Configure where the Data Collector data is stored.
a If necessary, change the path where data is stored. 

24 Enterprise Manager 2014 R2 Installation Guide


Complete the Data Collector Setup Wizard

b Click Next. The SMI‐S Server Properties page appears.

4 (Optional) Configure SMI‐S Server Properties.
a To configure SMI‐S at this time, select Enabled, then configure the remaining 
properties.

Note: You can also configure SMI‐S after the Data Collector is installed and 
configured. For information on setting up and using SMI‐S, see the Dell 
Compellent Enterprise Manager Administrator’s Guide.

b Click Next. The Network Adaptor and Max Memory Settings page appears.

5 Select the network adapter and specify the memory limit for the Data Collector.
a If the server that hosts the Data Collector has multiple network adapters, select 
which adapter the Data Collector should use for communication.
 To select a network adapter automatically, select the Automatically Select 
Network Adapter check box.
 To manually select a network adapter, choose a network adapter from the drop‐
down menu.
b In the Max Memory Settings area, choose an option to specify the maximum 
amount of memory that can be used by the Data Collector. If the Data Collector 
manages many Storage Centers, increasing this limit can improve performance.

Dell Compellent 25
Chapter 3 Installing and Configuring the Data Collector

Note: Dell Compellent recommends specifying a value that is less than total 
memory available to the Data Collector host server.

c Click Next. The Create Administrator User page appears.

6 Create an administrator user.
a Enter a user name, password, and password confirmation.

Note: Record the user name and password. You will need this information to 
log on to Enterprise Manager after installation is complete.

b Click Next. The Data Collector Service is started. After the Data Collector starts, the 
Finished setup page appears.

7 Record the URL for the Data Collector website, then click Finish. The Enterprise 
Manager Data Collector Setup wizard exits.

26 Enterprise Manager 2014 R2 Installation Guide


4 Installing and Configuring the Enterprise
Manager Client

Install the Client on a Windows computer and use it to connect to the Data Collector.

Contents
Install the Enterprise Manager Client  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   27
Use the Client to Connect to the Data Collector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   28
Add Storage Centers to Enterprise Manager  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   29
Next Steps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   30

Install the Enterprise Manager Client


The Enterprise Manager Client is a Windows application that connects to the Data 
Collector, allowing you to view and manage multiple Storage Centers. You can install the 
client on the Data Collector server or a computer that has network connectivity to the Data 
Collector server. 
Prerequisites
The host computer must meet the requirements listed in Client Requirements on page 4.
Steps
1 In a web browser, go to the Enterprise Manager Data Collector Website. The default 
location for the website is:
https://<emdc_hostname_ip>:<emdc_web_server_port>

Variable Description
emdc_hostname_ip Host name or IP address of the Data Collector server.

emdc_web_server_port Web server port of the Data Collector server. The default port is 3033.

2 If a certificate warning appears, acknowledge the warning and continue.
3 Next to Client Installer, click Download to save the Enterprise Manager Client Installer 
to your computer.
4 When the download is complete, double‐click the downloaded file. A Security Warning 
dialog box appears.
5 Click Run to start the installation. The InstallShield Wizard appears.
6 Use the wizard to install the Enterprise Manager Client.

Dell Compellent 27
Chapter 4 Installing and Configuring the Enterprise Manager Client

Use the Client to Connect to the Data Collector


After the Enterprise Manager Client is installed, use it to connect to the Data Collector.
1 Start the Enterprise Manager Client application. The Enterprise Manager Client 
appears.

2 Complete the following fields:
 User Name: Enter the name of the Enterprise Manager user that was created during 
Data Collector installation.
 Password: Enter the password for the user.
 Host/IP: Enter the host name or IP address of the server that hosts the Data Collector. 
If the Data Collector and Client are installed on the same system, you can type 
localhost instead.
 Web Server Port: If you changed the Web Server Port during installation, enter the 
updated port.

Note: Do not select the Use Windows Credentials check box at this time. To use 
this feature, the Data collector must be configured for Active Directory and 
Kerberos.

3 Click Log In. The Client connects to the Data Collector and displays the Storage (SAN/
NAS) view.

28 Enterprise Manager 2014 R2 Installation Guide


Add Storage Centers to Enterprise Manager

Add Storage Centers to Enterprise Manager


Use the Client to add the Storage Centers that you want to centrally manage.
Prerequisites
 You must have the user name and password for a Storage Center user account.
 The first time a Storage Center is added to Enterprise Manager, you must specify a 
Storage Center user account that has the Administrator privilege. When the Storage 
Center is subsequently added for other Enterprise Manager users, you can specify 
Storage Center user accounts any privilege level.
 If your Enterprise Manger user account has the Reporter privilege, you must specify 
a Storage Center user account that has the Reporter privilege.
 The Enterprise Manager Data Collector must have connectivity to the Storage Center 
management interface.
 The Storage Center certificate must contain the host name or management IP address 
that is used to add the Storage Center to Enterprise Manager. For instructions on 
regenerating an SSL certificate, see the Storage Center Administrator’s Guide.
Steps
1 In the Enterprise Manager Client, click Add Storage Center. The Add Storage Center 
dialog box appears.

Note: If one or more Storage Centers are associated with other Enterprise 
Manager users, the dialog box allows you to select an existing Storage Center or 
add a new Storage Center.

2 Enter Storage Center logon information.
 Host Name: Enter the host name or IP address of a Storage Center controller. For a 
dual‐controller Storage Center, enter the IP address or host name of the management 
controller. 
 User Name and Password: Enter the user name and password for a Storage Center 
user.

Note: If you specify a Storage Center user with the Reporter or Volume 
Manager privilege, access to the Storage Center from Enterprise Manager is 
restricted based on the privilege and user group(s) assigned to the Storage 
Center user.

 Folder: Select the parent folder for the Storage Center.
3 (Optional) Configure the Storage Center to use settings applied to another Storage 
Center by selecting the Inherit settings from existing Storage Center check box. If this 
check box is selected, after the wizard closes the Inherit Settings wizard appears.
4 Click Finish.
 If the Inherit settings from existing Storage Center check box was not selected, the 
Storage Center is added to Enterprise Manager.
 If the Inherit settings from existing Storage Center check box was selected, the 
Inherit Settings dialog box appears.

Dell Compellent 29
Chapter 4 Installing and Configuring the Enterprise Manager Client

5 (Inherit settings only) Choose the Storage Center settings to inherit.
a Select the Storage Center from which you want to inherit settings, then click Next. 
The wizard advances to the next page.
b Select the check box for each category of settings that you want to inherit. For user 
interface reference information, click Help.
c When you are done, click Finish. 
 If passwords are not configured for the Phone Home proxy, Secure Console 
proxy, or SMTP server, the dialog box closes.
 If a password for the Phone Home proxy, Secure Console proxy, or SMTP server 
is configured, you are prompted to re‐enter the required password(s).
d Enter the required password(s) to complete the wizard.

Next Steps
After installation is complete, perform basic tasks to configure Enterprise Manager for your 
environment. These tasks are configuration dependent so some might not apply to your 
site.
See the Enterprise Manager Administrator’s Guide for detailed configuration instructions, 
including how to:
 Add Enterprise Manager users.
 Configure the Data Collector to authenticate Enterprise Manager users using an Active 
Directory or OpenLDAP directory service.
 Add Storage Center volumes.
 Add servers to Storage Centers.
 Add FluidFS clusters to Enterprise Manager.
 Configure email notifications.
 Set up remote Storage Centers and QoS.
 Configure replications and Live Volumes.
 Predefine your disaster recovery plan.

30 Enterprise Manager 2014 R2 Installation Guide


680-028-018 A