Você está na página 1de 2

Rain+Birdt Tech Spec

ESP-TM2 Controller Features


• NEW large back-lit LCD display for
Fixed Station improved visibility in low-light and direct
sunlight conditions
Controller • Familiar, easy to navigate user interface
• Rain sensor input with bypass capability
ESP-TM2 Series Controllers • Master valve/pump start circuit
Rain Bird’s ESP Series of controllers has • Nonvolatile (100 year) storage memory
been expanded to offer a contractor grade • Electronic diagnostic circuit breaker
irrigation controller for residential and light
commercial applications. • Remote accessory port for Rain Bird
approved accessory devices
The ESP-TM2 Controller is available in four
models suitable for indoor or outdoor Scheduling Features
applications (4-Station, 6-Station, 8-Station • Program based scheduling with 3 indi-
and 12-Station). vidual programs and 4 independent start
times per program for 12 total start times Electrical Specifications
Applications
• Watering schedule options: Custom Days • Input required: 120VAC (±10%) @ 60Hz
The ESP-TM2 provides flexible scheduling of the week, ODD or EVEN calendar days,
features to accommodate a wide variety • Output: 1A at 24VAC
or Cyclic (every 1 – 30 days)
of landscape applications. Plus powerful • Master Valve/Pump Start Relay
advanced irrigation features that help Advanced Features
to meet any type of regional watering • External battery back-up not required.
• Manual Watering option for all stations, Nonvolatile memory permanently saves
restrictions.
a single station or an individual program the current programming and a 10
Easy to Use • Seasonal Adjust applied to all programs year life lithium battery maintains the
or an individual program controllers time and date during power
The ESP-TM2 Controller is designed to be outages.
an easy to use, program-based controller • Delay Watering up to 14 days (applies
with the familiar ESP user interface, a large only to stations set to obey Rain sensor) Certifications
LCD screen and universal icons on both the • Permanent Days Off (for Odd, Even or • UL, cUL, FCC Part 15b
controller overlay and the LCD. Cyclic programming)
• IP24
Easy to Install • Sensor bypass for all programs or for indi-
vidual stations Dimensions
The ESP-TM2 Controller requires only
two screws for easy wall mounting. For • Adjustable delay between stations • Width: 7.92 in. (20,1 cm)
professional installation, it has a guide for • Contractor Default™ Program Save and • Height: 7.86 in. (20,0 cm)
½“ or ¾” conduit to run field wires into the Restore saved program(s) • Depth: 3.51 in. (9,0 cm)
unit. A factory installed 6’ pigtail offers a
• Master Valve on/off by station
plug and play solution out of the box.
• Automatic short detect with station
Controller Hardware specific alarm messages
• Plastic wall-mount cabinet with door Operating Specifications
• 4, 6, 8 or 12 station models • Station timing: 1 minute to 6 hours
• Mounting screws with anchor shields • Seasonal Adjust: 5% to 200%
• Factory installed pigtail How To Specify:
• Max operating temperature: 149°F (65°C)
ESP-TM2 Models
• TM2-4-120V
• TM2-6-120V
• TM2-8-120V
• TM2-12-120V
Rain+Birdt

Specifications The controller shall have a Seasonal Adjust The controller shall operate on 120VAC
feature to adjust the run time from 5% to (±10%) at 60Hz. If connected, a master
The ESP-TM2 Controller is a hybrid type 200% in 5% increments. Seasonal Adjust valve or pump start shall operate on 24VAC
combining electromechanical and micro- shall be capable of being applied to all at 60Hz.
electronic circuitry. The controller shall programs simultaneously or to individual
be capable of fully automatic or manual programs. The controller shall have an electronic
operation. The controller shall be housed diagnostic circuit breaker that can detect if
in a wall-mountable, weather resistant The controller shall have a Delay Watering a station has an electrical overload or short
plastic cabinet with lockable door (lock not feature that can override and suspend circuit condition. The controller shall then
included). programmed watering for up to 14 days. bypass the error detected station while
continuing to operate all other stations.
The controller shall have 3 independent The controller shall have a Permanent Days
programs that allow 4 different start times Off feature that is available for Odd, Even, The controller shall have a reset button to
per program. Firmware programming shall and Cyclic days programming. A day set to re-boot the factory default firmware, in
automatically stack multiple start times in “Permanent Off” shall override the normal case of controller interface “freezing” due to
sequence to prevent hydraulic overload. All repeating schedule. a power surge or interruption of power to
programs shall run consecutively. the power supply.
The controller shall be equipped with
Watering day schedules shall be: Custom a variety of Special Features that can The controller shall provide an option for
Days of the Week, Odd or Even calendar be accessed by turning the dial to the the installer to run field wires through a
days and Cyclic (such as every 2 days, or appropriate dial position and then pressing ½” or ¾” wire conduit fitting, allowing for a
every 3 days, etc.). When the dial is turned and holding both the left and right arrow clean, professional installation.
to the RUN DAYS position, the display shall (or back and next) keys simultaneously for
indicate the active schedule type (Odd, 3 seconds. The controller shall be compatible with Rain
Even, or Cyclic) for the selected program. Bird’s LIMR (Landscape Irrigation Mainte-
Special Features shall include: nance Remote) and have a 5-pin accessory
Station run times shall range from 1 minute port to communicate with Rain Bird ap-
to 6 hours. • Set Interstation Delay proved expansion accessories.
• Reset to Factory Defaults
The controller shall have a 12-hour AM/PM Suggested accessories for use with this
and/or 24 hour mode clock with a midnight • Rain Sensor Bypass by Station controller:
day change over. The controller shall have • Save/Restore Programming
a 365-day calendar backed up against • Rain Bird RSD Series Rain Sensors
• Set Master Valve By Station
power interruptions by an internal lithium • Rain Bird WR2 Wireless Rain/Freeze Sen-
battery that shall maintain date and time The controller shall provide the ability to sors
for approximately 10 years. clear all programming and reset to factory
• Rain Bird Landscape Irrigation & Mainte-
default settings if desired.
The controller shall offer Manual Watering nance Remote (Available in USA/Canada
options including all stations, any single The controller shall provide a method for Only)
station or any individual program. When the operator to save an irrigation schedule • All Rain Bird residential and commercial
manual watering is triggered, the unit shall into nonvolatile memory for future recall. rotors, valves, nozzles, sprays and drip
ignore the status of a rain sensor (if con- products
nected) and re-enable the sensor when The controller shall be capable of operating
manual watering is completed. one 24VAC solenoid valve per station plus a The ESP-TM2 controller shall be manufac-
separate master valve or remote pump start tured by Rain Bird Corporation in a NAFTA
The controller shall be capable of bypassing relay. member country.
a rain sensor (if connected) for each station
independently.

Rain Bird Corporation Rain Bird Corporation Rain Bird International, Inc.
6991 East Southpoint Road 970 West Sierra Madre Ave. 1000 West Sierra Madre Ave.
Tucson, AZ 85756 Azusa, CA 91702 Azusa, CA 91702
Phone: (520) 741-6100 Phone: (626) 812-3400 Phone: (626) 963-9311
Fax: (520) 741-6522 Fax: (626) 812-3411 Fax: (626) 852-7343

Rain Bird Technical Services Specification Hotline The Intelligent Use of Water TM


(800) RAINBIRD (1-800-724-6247) 1-800-458-3005 (U.S. and Canada) www.rainbird.com
(U.S. and Canada)

Registered trademark of Rain Bird Corporation


2016 Rain Bird Corporation 15JN16 D40874EO

Você também pode gostar