MANUAL:
• INSTALLATION
• USE
• MAINTENANCE
FOREWORD 3
WORKING 3
COSTRUCTION 3
TECHNICAL FEATURES 4
STOP PREARRENGEMENT 4
WIRINGSYSTEM 5
FOREWORD
PM2-C module has been designed to control all parameters of motor while running.
WORKING
While motor is still, the pilot lights of LOW OIL PRESSURE and BATTERY CHARGING
GENERATOR are on. On starting, protections are enabled with a 2-minute delay. During that time,
the operator may start without PM2-C turning to emergency and stopping motor.
If starting operation exceeds the preset delay time, the led BLOCCO of PM2-C, will turn on.
In this case, position key to OFF again and repeat.
When starting up motor, the first delay time is cut out and a 10 second delay time is set. Should
failure occur while running, the relevant led will turn on PM2-C will turn to emergency and block
motor. All pilot lights on the panel that are on when the motor is still remain on.
PM2-C is made of oxidized aluminum panel, protection class IP 42 and is provided with:
0 = it disconnected
AUTOMATIC AUTOM. protections connected
STARTING AVV. (position with spring return) for starting motor
STOP BUTTON
PILOT LIGHTS
TECHNICAL FEATURES
PROTECTION DEGREE IP 42
SUPPLY VOLTAGE 12V/24Vdc
MAX STOP RATING 16A
PROTECTION ENABLING TIME AFTER STARTING 10sec
STOP DELAY 30-60sec
WORKING TEMPERATURE -20°C + 60°C
CONNECTIONS Faston 6,3 mm
PANEL SIZES 96x96 mm.
DEPTH 72 mm.
BOX NORYL DIN43700
PM2-B
JP1
A CONNECTION
B P
PM2-B
JP1
A CONNECTION
B P
KEY GROUP
30 50 15/54
PM2
FAST.8
STARTING
+ BATTERY
G
P
STOP STOP STOP
M
1 16A 16A
2
2
B
1 2 3 4 5 6 7 8 9
-B W
15/54
K
I
E
Y R
30 50 I
N
FUS
G
1 1 1
1
30A
2
+
2 2 2
STOP FUEL WAT. GEN. LOW OIL STOP BATT START STOP
RES. TEMP. PRESS. EM EV