Você está na página 1de 2

EVOS® XL Core 1

EVOS® XL Core 1
Attachable Mechanical Stage Attachable Mechanical Stage
Installation Note Installation Note

Follow this procedure to attach the mechanical Follow this procedure to attach the mechanical
stage to the fixed stage. To remove the stage, do stage to the fixed stage. To remove the stage, do
the steps in reverse order. the steps in reverse order.

Install Attachable Mechanical Stage 2 Install Attachable Mechanical Stage 2


Note: R
 emove the glass stage plate (if it is Note: R
 emove the glass stage plate (if it is
already installed) and set it aside. already installed) and set it aside.
1. Tilt the LCD all the way back and gently 1. Tilt the LCD all the way back and gently
lay the microscope on its left side. lay the microscope on its left side.
2. S
 lide the mechanical stage  into position 2. S
 lide the mechanical stage  into position
over the right side of the fixed stage . 1 3 over the right side of the fixed stage . 1 3

3. A
 lign the mechanical stage so that the 3. A
 lign the mechanical stage so that the
two screws  under the mechanical stage two screws  under the mechanical stage
align with two holes  under the fixed 2 align with two holes  under the fixed 2
stage.
4 stage.
4

4. Tighten the left screw  by hand first. 4. Tighten the left screw  by hand first.
5. Use the hex key to tighten the right screw  5. U
 se the hex key to tighten the right screw 
(behind the focus knob). Then fully tighten (behind the focus knob). Then fully tighten
the left screw  with the hex key. the left screw  with the hex key.
6. Stand the microscope upright. 1 6. Stand the microscope upright. 1
5 5
install Glass Stage Plate install Glass Stage Plate

1. Move the mechanical stage all the way 2 1. Move the mechanical stage all the way 2
back to expose the stage opening. 6 back to expose the stage opening. 6
2. Insert the glass stage plate (not shown) 2. Insert the glass stage plate (not shown)
into the stage opening. into the stage opening.
EVOS® XL Core EVOS® XL Core
Attachable Mechanical Stage Attachable Mechanical Stage
Installation Note Installation Note

Stage clip Stage clip


Use the stage clip to secure vessel holders or large Use the stage clip to secure vessel holders or large
samples (i.e. a T-75 flask or multi-well vessel) to samples (i.e. a T-75 flask or multi-well vessel) to
the mechanical stage. When properly secured, the mechanical stage. When properly secured,
the sample moves with the stage as you turn the the sample moves with the stage as you turn the
X-axis and Y-axis knobs. X-axis and Y-axis knobs.
1. P
 ull the stage clip open and place the vessel 1. Pull the stage clip open and place the vessel
holder or sample in the back right corner holder or sample in the back right corner
of the mechanical stage opening. Verify of the mechanical stage opening. Verify
that the edges are straight and the sample that the edges are straight and the sample
is level. is level.
2. G
 ently release the stage clip. 2. Gently release the stage clip.

Stage Y-axis knob Stage Y-axis knob


Mechanical Stage Controls Mechanical Stage Controls
Use the stage Y-axis knob for front-back Use the stage Y-axis knob for front-back
movements to position the specimen within the movements to position the specimen within the
field of view. field of view.

Stage X-axis knob Stage X-axis knob


Stage clip Stage clip
Use the stage X-axis knob for left-right Stage Y-axis knob Use the stage X-axis knob for left-right Stage Y-axis knob
movements to position the specimen within the Stage X-axis knob movements to position the specimen within the Stage X-axis knob
field of view. field of view.

® ®

lifetechnologies.com/evos ZP-PKGA-0587[01] lifetechnologies.com/evos ZP-PKGA-0587[01]