Você está na página 1de 8

T e l:

F a x:
ISO
9001
20140531(V1.1)
SGS
FR100 Series Multifunctional Inverter
1-Phase 220V 0.2-2.2kW
3-Phase 220V 0.2-2.2kW
3-Phase 380V 0.75-4.0kW

-Optim ized VF control


-Bulit-in simple EMC filter
-Keyboard potentiometer control
-Track-mounted design
-Output short circuit protection
-Characteristics of the uploading and
downloading module optional
-With a high-speed pulse input

FR200 Series Vector control inverter


3-Phase 380V 0.75-710kW

-G-type and P-type machines two-in-one


-Sensorless vector control
-Flanges(Through wall)Mounting Design
-Machines with 90kw or above
-Characteristics of the uploading and downloading
module optiona
-Output short circuit protection and Hardware for fast
current limit
-With one high-speed pulse input port,one High Speed pulse
output port and one -10 to +10 V voltage input port

Options
Uploading and downloading module
FR100 Keyboard
FR200 Keyboard
Multifunction Inverter

Summarize:
FR100 Series multifunction inverter is a compact, feature-rich, and highly price-competitive
models.Particularly suitable for electronic equipment, food packaging, woodworking, treadmills and
other small power transmission applications.It has the following main Features as below:
-Optimized VF control
-Bulit-in simple EMC filter
-Track-mounted design
-Characteristics of the uploading and downloading module for choosing
-MODBUS communication supported
-According to the temperature of the inverter to intelligent
control the cooling fan start or stop
-The maximum output frequency reaches 600.00Hz
- Four groups of time acceleration and deceleration optional
-Operation mode selectable when warning
-Support functions of counting、fixed length、sleep and aweaken
-Quick release design when Cleaning or replacing the fan
Model Terminal Terminal name Terminal function
- Keyboard potentiometer control
-Output short circuit protection Supply +10V power ,Maximum output current:10mA;
+10V-GND +10V power Generally used as an external potentiometer Power supply,Potentiometer
- With one high-speed pulse input resi stance range:1~5kO.
power
-Support PID,16-segment multi-speed,The program runs,Wobbulation operating Provide +24 V power outward, i s generally used as a digital input and
+24V-GND 24V power output terminals of the power supply and an external sensor supply, the
maxi mum output current: 200mA
F R 1 0 0 Series Electrical Specifications
Input range: DC 0 ~ 10V / 0 ~ 20mA, the control panel AI1, AI2 toggle
AI1-GND Anal og i nput 1 swi tch.
Powercapacty Rated input Rated output Motor PowerMotor Power Input impedance: Input voltage 250kO, current 250O
Model No. kVA current (A) current (A) kW HP
Analog i nput
Input range: DC 0 ~ 10V / 0 ~ 20mA, the control panel AI1, AI2 toggle
AI2-GND Anal og i nput 2 swi tch.
1-Phase:220V,50/60Hz Input impedance: Input voltage 250kO, current 250O
DI1- GND Di gi tal input 1
FR100-2S-0.2B 0.5 4.9 1.6 0.18、0.2、0.25 0.25 DI2- GND Di gi tal input 2
Maxi mum i nput frequency: 200Hz
Input impedance: 2.4kO
DI3- GND Di gi tal input 3
FR100-2S-0.4B 1.0 6.5 2.5 0.37、0.4 0.5 Digital
DI4- GND Di gi tal input 4
Level i nput voltage range: 9V ~ 30V
i nputDigital input
FR100-2S-0.7B 1.5 9.3 4.2 0.75 1.0 Digital i nput 7or Except DI1 ~ DI6 characteristics, but also as high-speed pulse i nput
DI7/HI-GND High-speed pulse channels. M aximum input frequency: 100kHz
FR100-2S-1.5B 3.0 15.7 7.5 1.5 2 input
Analog
FR100-2S-2.2B 4.0 24 9.5 2.2 3 Analog output 1Analog Output RangeOutput Range:0V~10V
outputAnalog AO1-GND
output 1 impedance requirementsimpedance requirements=10kO
output
3-Phase:220V,50/60Hz
Digital Voltage range: 0~24V
FR100-2T-0.2B 0.5 1.9 1.6 0.18、0.2、0.25 0.25 outputDigital Y1-GND Open collector output 1
Current range: 0~50mA
output
FR100-2T-0.4B 1.0 2.7 2.5 0.37、0.4 0.5 Relay R1A-R1C Normal ly open termi nal Contact dri ving ability:
outputRelay AC250V, 3A, COSØ = 0.4.
FR100-2T-0.7B 3.0 4.9 4.2 0.75 1 output R1B-R1C
Normally cl osed
DC 30V, 1A
termi nal
FR100-2T-1.5B 4.0 9.0 7.5 1.5 2 485 communication
485+-485-
485 termi nal RateRate:4800/9600/19200/38400/57600/115200bps
FR100-2T-2.2B 6.0 11 9.5 2.2 3
communication 485 communication RS485 DIP switch settings on the control board termination resi stors
GND
3-Phase:380V,50/60Hz Shield ground

FR100-4T-0.7B 1.5 3.4 2.5 0.75 1 shi eld PE Shield ground Shield ground terminals for wi ring

FR100-4T-1.5B 3.0 5.0 4.2 1.5 2 External Keyboard Up to 50 meters distance communication connecting the operation panel
Interface
FR100-4T-2.2B 4.0 5.8 5.5 2.2 3 Auxiliary Interfac
UP/DOWNLOAD Parameter copy card Usi ng standard network cable ( (RJ45)
FR100-4T-4.0B 6.0 11 9.5 3.7、4 5 interface
Rated i nput voltage Singl e-phase220VAC/3-phase220VAC/3-phase 380VAC,tolerance -15~+30%

Rated input frequency 50/60Hz, tolerance ±5%


Power
input The highest output voltage 0~Rated i nput voltage, tolerance ±3%
outpu
The highest output voltage 0.00~600.00 Hz,Unit 0.01Hz

Over load capabilli ty 150% one minutes, 180% ten seconds, 200% two seconds

Control pattem V/f control Speed-sensorl ess control 1

Speed range 1:50 1:100

Speed accuracy ±0.5% ±0.2%


Control
Speed ripple - ±0.3%
charact
Starting torque 1Hz 100% 0.5Hz 150%
eristics
Carrier frequency 0.7~16kHz

Torque boost Auto torque boost; Manual torque boost 0.1~30.0%

V/F curve Three ways: straight; multi-point;N-th power V/F curve

Simple PLC, M ulti-step Through the si mpl e PLC function or control termi nal to achieve up to 16-step speed
speed control programmable
PID Easy to i mplement process control loop control system

Standard RS485 i nterface,In addition to traditional comm unication applications, Renyiyitai set to
RS485 communication and
host the role of the inverter wi th synchronous controller (point to poi nt communicati on)
synchronization control

Acceleration, deceleration Time Range 0.1 ~ 6000.0s And Linear, S curve type mode selectabl e

time setting Overall and installation dimensions(mm)


DC braki ng start frequency:0.00~Fmax, DC braking time:0.0~10.0s
Model No. Weight
DC braki ng capability Mounting Mounting
DC braki ng current:0.0~150.0% W H D W1 W2 H1 H2 H3 H4 (Kg)
holes d1 holes d2
Jog Control Jog frequency:0.00~50.00Hz,Jog Acceleration, deceleration time:0.0~6000.0s Single-phase power:220V,50/60Hz
AutomaticVoltage Regulation Jog Acceleration, deceleration time:0.0~6000.0sJog Accel eration, deceleration time:0.0~6000.0s FR100-2S-0.2B
When the input voltage changes,i t can automatical ly maintain a constant output voltage
FR100-2S-0.4B 95 162 120 85 11 151.5 152 110.8 130 4.5 4.5 1.1
Overvoltage and
Automatically l imit the current and voltage,Prevent the inverter Overcurrent or Overvoltage FR100-2S-0.7B
overcurrent stall control
FR100-2S-1.5B
Basi c Command source Keypad, control terminal, serial communication port.,There are several ways to swi tch
110 173 135 100 11 163 163 121.8 140.5 4.5 5 1.5
There are several ways to swi tch FR100-2S-2.2B
functions Digital setting,keypad Potentiometer setti ng, Analog voltage setting, Analog current
Frequency
setting,terminal pulse setting, seri al communicati on setting, Multi-step speed setting,PLC 3-phase power:220V,50/60Hz
command modes
setting,PID setting. There are several ways to switch FR100-2T-0.2B

5 input termi nals, one of which can be used for high-speed pulse input. FR100-2T-0.4B 95 162 120 85 11 151.5 152 110.8 130 4.5 4.5 1.1
Run
Input termi nals
2 analog inputs, one of which can be select voltage or current, 0 ~ 10V / 0 ~ 20mA FR100-2T-0.7B

FR100-2T-1.5B
1 Digital output terminal 110 173 135 100 11 163 163 121.8 140.5 4.5 5 1.5
Output terminals 1 Rel ay output termi nals FR100-2T-2.2B

1 Analog output terminal 3-phase power:380V,50/60Hz


Keypad Lock &Multifunction Realize some or all of the key lock;Defi ne some key’s function to prevent misuse
FR100-4T-0.7B

key Define some key’s FR100-4T-1.5B


Monitoring information of In run or stop,It canfunction to prevent
be set four objectsmisuse
of U00 group to monitor.
110 173 135 100 11 163 163 121.8 140.5 4.5 5 1.5
Run and stop FR100-4T-2.2B
Offers a dozen fault protection features: overcurrent, overvoltage, undervoltage,
Protection
overtemperature, overload protection function FR100-4T-4.0B
Installation Wall or rail mounting

www . frecon . com . cn www . frecon . com . cn


FR200 series vector control inverter positioned as high-end market OEM customers and
the specific requirements of fan and pump and other loads applications. FR200 design flexibility,
embedded SVC and VF control in one, can be widely used for Applications that require high
speed control accuracy, speed torque response, low-frequency output . In addition to all the
features included FR100, but also has the following main features:
-Support torque control
-Sensorless Vector Control
-Plug-threading hole design
-Integrated model with G&P in one
-Support function code parameter backup
-Flange (wall) mounting design
-Built-in brake unit is optional for the equipments with 37~75kw.
-Reactor built-in the equipments with 90kw or above.
-With a high-speed pulse output and a -10 V to +10 V voltage input

F R20 0-4 T-0 .7G /1. 5PB 1 .5 3 .4 2 .5 0 .75 1


F R20 0-4 T-1 .5G /2. 2PB 3 .0 5 .0 4 .2 1 .5 2
F R20 0-4 T-2 .2G /4. 0PB 4 .0 5 .8 5 .5 2 .2 3
F R20 0-4 T-4 .0G /5. 5PB 6 .0 11 9 .5 3 .7、 4 5
F R20 0-4 T-5 .5G /7. 5PB 8 .9 1 4.6 1 3.0 5 .5 7 .5
F R20 0-4 T-7 .5G /01 1PB 1 1.0 2 0.5 1 7.0 7 .5 10
F R20 0-4 T-0 11G /01 5PB 1 7.0 2 6.0 2 5.0 1 1.0 15
F R20 0-4 T-0 15G /01 8PB 2 1.0 3 5.0 3 2.0 1 5.0 20
F R20 0-4 T-0 18G /02 2PB 2 4.0 3 8.5 3 7.0 1 8.5 25
F R20 0-4 T-0 22G /03 0PB 3 0.0 4 6.5 4 5.0 22 30
F R20 0-4 T-0 30G /03 7PB 4 0.0 6 2.0 6 0.0 30 40
FR 200 -4T -03 7G/ 045 P 5 7.0 7 6.0 7 5.0 37 50
FR 200 -4T -04 5G/ 055 P 6 9.0 9 2.0 9 1.0 45 60
FR 200 -4T -05 5G/ 075 P 8 5.0 1 13. 0 11 2.0 55 70
FR 200 -4T -07 5G/ 090 P 11 4.0 1 57. 0 15 0.0 75 1 00
FR 200 -4T -09 0G/ 110 P 13 4.0 16 0 .0 17 6.0 90 1 25
FR 200 -4T -11 0G/ 132 P 16 0.0 1 90. 0 21 0.0 1 10 1 50
FR 200 -4T -13 2G/ 160 P 19 2.0 23 2. 0 25 3.0 1 32 1 75
FR 200 -4T -16 0G/ 185P 23 1.0 2 82. 0 30 4.0 1 60 2 10
FR 200 -4T -18 5G/2 00P 24 0.0 3 26. 0 35 0.0 1 85 2 50
FR 200 -4T -20 0G/ 220 P 25 0.0 3 52. 0 37 7.0 2 00 2 60
FR 200 -4T -22 0G/ 250 P 28 0.0 3 85. 0 42 6.0 2 20 3 00
FR 200 -4T -25 0G/ 280 P 35 5.0 43 7. 0 47 0.0 2 50 3 30
FR 200 -4T -28 0G/ 315 P 39 6.0 4 91. 0 52 0.0 2 80 3 70
FR 200 -4T -31 5G/ 355 P 44 5.0 58 0 .0 60 0.0 3 15 4 20
FR 200 -4T -35 5G/ 400 P 50 0.0 62 4. 0 65 0.0 3 55 4 70
FR 200 -4T -40 0G/ 450 P 56 5.0 6 90. 0 72 5.0 4 00 5 30
FR 200 -4T -45 0G/ 500 P 62 3.0 7 65. 0 80 0.0 4 50 6 00
FR 200 -4T -50 0G/ 560 P 67 0.0 8 35. 0 86 0.0 5 00 6 60
FR 200 -4T -56 0G/ 630 P 77 0.0 9 60. 0 99 0.0 5 60 7 50
FR 200 -4T -63 0G/ 710 P 85 5.0 1 050 . 0 1 100. 0 6 30 8 40
Rated input voltage Three-phase 380V, allowing fluctuation range -15 to +30%
Rated Input Frequency 50/60Hz, fluctuation range of ± 5%
The maximum output 0 ~ rated input voltage, the error is less than ± 3%
Input
voltagemaximum
The output 0.00 ~ 600.00 Hz, units of 0.01Hz
output
frequency G-type machine: 150% for 1 minute, 10 seconds of 180%, 200% 2 seconds
Overload capacity p-type: 120% 1 minute, 10 seconds 145%, 160% for 2 seconds

Control mode V/F control Vector control without PG Vector control without PG 2

peed range 1:50 1


1:100 1:200
M odel Terminal T erm inal name T erm inal function Speed control ±0.5% ±0.2% ±0.2%
Supply +10V power ,M axim um output current:10mA;
Control Rateaccuracy
fluctuations - ±0.3% ±0.3%
+10V-GND +10V power Generally used as an external potentiometer Power supply,
Potenti om eter resistance range: 1~ 5kO. Characteristics Starting torque 1Hz 100% 0.5Hz 150% 0.25Hz 150%
Provide +24 V power outward, i s generally used as a digital input and
power +24V-COM 24V power output terminals of the power supply and an external sensor supply, Carrier Frequency 0.7kHz~16kHz
the m axim um output current: 200m A
Torque boost Automatic torque boost; Manual torque boost from 0.1 to 30.0%
T he factory default connecti on to +24 V;
PLC External power input When usi ng an external si gnal dri ve DI1 ~ DI7, PLC to be connected V / F curve Three ways: straight; multi-point type; N th-type V / F curve
terminal to an external power source,
And disconnect the +24 V power terminal.

Input range: DC 0 ~ 10V / 0 ~ 20m A, the control panel AI1, AI2 toggle Simple PLC, multi-speed Through the built-in PLC or control terminal to achieve up to 16 speed running
AI1-GND Analog input 1
swi tch.
operation
Built-in PID Facilitate the realization of process control loop control system
Analog input
AI2-GND Analog input 2 Input impedance: Input voltage 250kO, current 250O RS485 communication Standard RS485 interface, in addition to traditional communication applications, through
AI3-GND Analog input 3
Input voltage range: DC -10 ~ +10 V and synchronization the RS485 communication interface, Renyiyitai setting role as the host of the drive with
Input impedance: 250kO
control synchronous controller (point to point communication)
M aximum i nput frequency: 200Hz
DI1- COM Digital input 1
Acceleration, 0.1 ~ 6000.0s continuous set, linear, S curve type mode selectable
DI2- COM Digital input 2 Input impedance: 2.4kO
deceleration
DC brakingtime DC braking frequency: 0.00 ~ maximum frequency
DI3- COM Digital input 3
Di gital i nput DI4- COM Digital input 4 Level input voltage range: 9V ~ 30V Braking time: 0.0 ~ 10.0s
DI5- COM Digital input 5 Braking action current value: 0.0 ~ 150.0%
DI6- COM Digital input 6 Jog Control Jog Frequency range: 0.00 ~ 50.00Hz
Di gital input 7or Except DI1 ~ DI6 characteristi cs, but also as high-speed pul se input
DI7/HI-COM
High-speed pulse input channels. M axim um input frequency: 100kHz Jog deceleration time :0.0 ~ 6000.0s.

AO1-GND Anal og output 1 Output Range: DC 0 ~ 10V / 0 ~ 20mA, the control panel AO1, AO2 Automatic voltage When the grid voltage changes, can automatically maintain a constant output voltage
Analog
toggle switch.
output = 10kO impedance requirements Basic regulation (AVR)
Fastcurrent limit Minimize overcurrent fault ,protect inverter running
AO2-GND Anal og output 2
functions function
Overvoltage System automatically limits of current and voltage during operation to prevent frequent
Voltage range: 0 ~ 24V
Y1-COM Open coll ector output 1
Digital output
Current range: 0 ~ 50mA Overcurrent stall
Command overcurrent and overvoltage
Given the control trip. terminal, serial communication port given. There are
panel, control
Open collector output 2 or Apart from Y1 characteristics, but also as a high-speed pulse output
Y2/HO-COM
high-speed pulse output channels. M axim um output frequency: 100kHz source
Frequency several
9 kindsways to switch sources: digital setting, keyboard potentiometer setting, analog
of frequency
R1A-R1C T he normally open terminal
given voltage, given analog current reference pulse is given, the serial port is given, multi-speed
R1B-R1C Norm ally closed termi nal Contact dri ving abi lity: given, PLC is given, the process PID reference. There are several ways to switch
Relay output AC250V, 3A, COSØ = 0.4.
R2A-R 2C T he normally open terminal DC 30V, 1A Input terminal 7 switch input terminals, one way to make high-speed pulseinput.
R2B-R 2C Norm ally closed termi nal 3-channel analog inputs, including 2-way 0 ~ 10V / 0 ~ 20mA voltage and current options,
Run
485
485+-485- 485 comm unication termi nal
Rate: 4800/9600/19200/38400/57600/115200bps a way to support -10 ~ +10 V input
comm unication GND 485 communication Shi eld RS485 DIP switch settings on the control board term ination resistors
ground
shield PE Shield ground Shield ground terminals for wi ring 2-way switch output terminal, which supports a maximum road speed 100kHz pulse
Up to 50 m eters distance comm unication connecting the operation
External Keyboard Interface panel output output.
Auxiliary
Interface
Parameter copy card
terminal 2 relay output terminals.
UP/DOWNLOAD Usi ng standard network cable (RJ45)
i nterface
2 analog output terminal, and optional voltage and current.
Overall and installation dimensions(mm)
Model NO.
W W1 H H1 D 4xd1
FR200-4T-0.7G/1.5PB
FR200-4T-1.5G/2.2PB 116.6 106.6 186.6 176.6 168 Ф4.5
FR200-4T-2.2G/4.0PB
FR200-4T-4.0G/5.5PB
FR200-4T-5.5G/7.5PB 146 131 249 236 177 Ф5.5
FR200-4T-7.5G/011PB
FR200-4T-011G/015PB
198 183 300 287 185 Ф5.5
FR200-4T-015G/018PB
FR200-4T-018G/022PB
FR200-4T-022G/030PB 255 176 459 443 220 Ф7
FR200-4T-030G/037PB
FR200-4T-037G/045P
270 130 590 572 260 Ф7
FR200-4T-045G/055P
FR200-4T-055G/075P
357 230 590 572 260 Ф7
FR200-4T-075G/090P
FR200-4T-090G/110P
FR200-4T-110G/132P 430 320 830 802 293 Ф12
FR200-4T-132G/160P
FR200-4T-160G/185P
FR200-4T-185G/200P 500 180 1107 1078 328 Ф14
FR200-4T-200G/220P
FR200-4T-220G/250P
FR200-4T-250G/280P 660 230 1160 1130 340 Ф14
FR200-4T-280G/315P
FR200-4T-315G/350P
FR200-4T-350G/400P 810 300 1140* 1110 400 Ф14
FR200-4T-400G/450P

Overall and installation dimensions(mm)


Model NO.
W W1 H D D1 4xd1
FR200-4T-450G/500P
FR200-4T-500G/560P
1200 1036 1900 480 316 Ф14
FR200-4T-560G/630P
FR200-4T-630G/710P