NOTE! Before starting the OHM tests turn the main power OFF and the test switch ON.
Symptoms Possible causes Action
Rope gripper does not reset Excessive wear microswitch Connect multimeter probes to (pump) in clamped position. contact open, brake ready RG3 and RG4. Check microswitch contact open. adjustment of contact. NOTE! If rotating shaft NOTE! The brake ready and activates the excessive wear excessive wear microswitches are microswitch, replace connected in series. the brake linings. If fault is detected Refer to AS- between RG3 and 04.08.090. RG4, remove wirings of the microswitches and measure which one is broken. Replace the faulty switches. Refer to AS-04.08.090. Elevator runs in the clamped Elevator can run microswitch Connect multimeter probes to position. contact closed. RG5 and RG6. Check adjustment of contact. Replace the faulty switches. Refer to AS-04.08.090. Elevator does not run in primed Valve microswitch contact Connect multimeter probes to position. open or elevator can run RG6 and RG7 (valve switch) microswitch contact open. RG5 and RG6 (elevator can run switch). Check adjustment of contact. Replace the faulty switches. Refer to AS-04.08.090. Rope gripper does not reach Oil level is too low. Check the oil level. primed position or does not Air in the hydraulic system. Check the hydraulic hold the pressure. Hydraulic component leaks. components. Replace leaking components. Add more oil if needed. Bleed air from the hydraulic system: Remove hose from the cylinder. Use hand pump until all air has come out. Pump cycles ON and OFF. Brake ready switch is not Check the adjustment correctly adjusted. according to section 9.