Hollister-Whitney rope gripper

Maintenance Guideline

11 TROUBLESHOOTING

NOTE! Before starting the OHM tests turn the main power OFF and the test switch ON.

Symptoms Possible causes Action


Rope gripper does not reset Excessive wear microswitch Connect multimeter probes to
(pump) in clamped position. contact open, brake ready RG3 and RG4. Check
microswitch contact open. adjustment of contact.
NOTE! If rotating shaft NOTE! The brake ready and
activates the excessive wear
excessive wear microswitches are
microswitch, replace connected in series.
the brake linings. If fault is detected
Refer to AS- between RG3 and
04.08.090. RG4, remove wirings of
the microswitches and
measure which one is
broken.
Replace the faulty switches.
Refer to AS-04.08.090.
Elevator runs in the clamped Elevator can run microswitch Connect multimeter probes to
position. contact closed. RG5 and RG6. Check
adjustment of contact.
Replace the faulty switches.
Refer to AS-04.08.090.
Elevator does not run in primed Valve microswitch contact Connect multimeter probes to
position. open or elevator can run RG6 and RG7 (valve switch)
microswitch contact open. RG5 and RG6 (elevator can
run switch). Check adjustment
of contact.
Replace the faulty switches.
Refer to AS-04.08.090.
Rope gripper does not reach Oil level is too low. Check the oil level.
primed position or does not Air in the hydraulic system. Check the hydraulic
hold the pressure. Hydraulic component leaks. components. Replace leaking
components.
Add more oil if needed.
Bleed air from the hydraulic
system: Remove hose from the
cylinder. Use hand pump until
all air has come out.
Pump cycles ON and OFF. Brake ready switch is not Check the adjustment
correctly adjusted. according to section 9.

© 2006 KONE Corporation ASG-04.08.090


All rights reserved. 16 (18) (-) 2006-03-02