PLUMBING CODE

201. A vent in a combustion waste and vent system shall be approximately equal in
area to one half.
b. Cross section area of the draw pipe

202. DWV material means


d. Drainage, waste and vent

203. Every passageway to an attic water heater shall have a solid continuous
flooring not less than
d. 24 inches wide = 2 feet

204. Every building in which plumbing fixture are installed shall have connection
to a :
d. Public or Private sewer

205. Allowing for friction and other pressure loss the available water pressure for
fixture is
c. 15 psi

206. The movement of water to the surface of a soil and into the soil below the
surface is
d. Infiltration

207. The size of supply piping outlet for any gas appliance shall be not less than
b. The inlet connection of the appliance

208. The quantity of water required to be supplied to every plumbing fixture shall
be represented by:
c. Fixture units

209. A pit or receptacle at a low point to which the liquid waste are drain
b. Sump

210. A fixture vent pipe increased one pie size its entire length
a. May exceed the maximum horizontal length limited by code

212. A storm drain sometimes located under the basement floor within the walls of
the building
a. Inside storm drain

213. What is the interval distance between clean-out along lateral line?
a. 15 m

214. Which type of fire line installation has become obsolete and seldom installed?
c. Local vent

215. Generally, what is the standard diameter of standpipe for buildings more than
six stories tall?
c. 6” inches

216. A pressure regulator should be installed when pressure exceeds


b. 80 psi

217. What is the copper content in brass fitting?


b. 85%

218. Is a device located at the bottom of the tank for the purpose of flushing
water closet and similar fixtures
b. Flush valve

219. The lowest portion of the interior part of any pipe or conduit that is not
vertical
d. Invert

220. What is the maximum height for the Hose Cabinet to be installed from the floor
line?
d. 4 ft

221. A structure built, erected and framed of component structure parts designed
for the housing, shelter, enclosure or support of person, animals or property of
any kind.
a. Building

222. A pipe connected from building gutter to the downspout


a. Header = shall be leader

223. A term used to described soil or waste system where all piping are threaded
pipe tubing or other rigid construction using recessed drainage fitting to
correspond to the types of piping
b. Durham System

224. Generally, what is the standard diameter of standpipe for buildings two or
three stories in height?
a. 4” inches

225. The pressure available at the fixture or water outlet, allowance is made for
pressure drop due at friction loss, head, meter and other losses in the system
during maximum demand period
b. Residual Pressure

226. In a line of piping is a combination of elbows or bends, which brings one


section of the pipe out of line but into a line parallel with the original section.
b. Offset

227. An open, unoccupied space, bounded on two(2) or more sides by the walls of the
building. An inner court is a court entirely within the exterior walls of the
building. All other courts are outer courts.
a. Court

228. A non-watertight lined excavation in the ground which receives the discharge
of a sanitary drainage system or part thereof, designed to retain the organic
matter and solids discharging therefrom, but permitting the liquid to seep through
the bottom and sides of the cesspool.
b. Cesspool

229. An approved plumbing fixture or device of such materials, shape and capacity
to adequately receive the discharge from indirect waste pipes, constructed and
located to readily cleaned.
b. Receptor

230. The normal force exerted by a homogeneous liquid or gas per unit of area on
the wall of the container
d. Pressure

231. An impairment of the quality of the water to a degree which creates hazard to
the public health and adversely affects the aesthetic and potable qualities of
waters for domestic use.
a. Pollution

232. Tube made of plastic material and colored black. The cross-sectional shape is
circular and is denotes by its outside diameter or O.D.
c. PE or Polyethylene

233. In what year, NAMPAP President Jaime M. Cabase spearhead the updating of the
Revised National Plumbing Code?
d. 1996

234. Number of lavatories for Assembly Places(Theather, Auditorium, Convention


Halls,etc) for public use for 350-female
b. 2 lavatories

235. In 1902, he was the first Chief of Plumbing Construction and Inspection
b. John F. Hass

236. Consists of a loaded air inlet valve, an internally loaded check valve, two
properly located test cocks and two isolation gate valves.
a. PVB or Pressure Vacuum Breaker Backflow Prevention Assembly

237. Number of urinal for Office for 420 person


c. 4 urinals

238. Revised Plumbing Code of 1999 was approved by President Joseph Estrada
a. December 21,1999

239. Plumbing Code for the City of Manila


c. City Ordinance 2411

240. Drainage Fixture Unit of water closet, public installation


a. 6 dfu

241. When President Ramon Magsaysay did signed the R.A. 1378, otherwise known as
the “PLUMBING
LAW OF THE PHILIPPINES”?
c. June 18, 1955

242. Type of Joints for soft copper water tubing shall be made with fittings
meeting approved
standards. The tubing shall be expanded with a proper flaring tool.
a. Flared joints

243. National Plumbing Code prepared by NAMPAP was Promulgated and approved by
Malacanang
c. January 28,1959

244. Drainage Fixture Unit of sink, bar, private 38 mm min waste


a. 1 dfu

245. Birth of Plumbing practice in the Philippines


b. 17th Century

246. Approval of House Bill No. 962 also known as RA No. 1378
c. 1954

247. The indirect waste lines carrying refrigeration waste shall not be smaller
than one (1) inlet serving not more than 2.8 mm3 of refrigeration
space.
a. 32 mm

248. Each grease trap shall have an approved water seal of not less than _____in
depth or the diameter of its outlet, whichever is greater
d. 51mm

249. Cleanouts may omitted on short horizontal drainage pipe installed at a slope
of _____ or less from the vertical line ( or an angle _____bend) and;
a. 45 degree ; 1/8 bend

250. Sizing of rainwater piping for two adjacent walls add _____of the total wall
areas to the roof area
d. 35%

251. Access to each septic tank shall be provided by at least two(2) manholes
_______ in minimum dimension or by an equivalent removable cover slab.
b. 508 mm

252. All septic tank covers shall be capable of supporting on earth load of not
less than ______ when the maximum coverage does not exceed 9 meters.
a. 14.4 kPa = 2 psi

253. Interceptors or clarifiers for sand and similar heavy solids shall be so
designed and located as to be readily accessible for cleaning and shall have a
water seal of not less than ____ deep.
a. 152 mm

254. Air test, air is forced into the pipe system until there is a uniform gauge
pressure of _____ or sufficient to balance a column of mercury 254 mm in height.
a. 34.5 kPa = 5 psi

255. No galvanized wrought iron or galvanized steel pipe shall be used underground
and shall be kept at least ___ above ground.
c. 152 mm

256. Dome-type strainers shall have a minimum total net inlet area of ________times
the area of the outlet pipe to which it is connected.
a. One and one-half