Você está na página 1de 1

Station/Unit April - 17 May - 17 June - 17 July - 17 Aug - 17 Sept - 17 Oct - 17 Nov - 17 Dec-17 Jan-18 Feb-18 Unitwise BTL

2
ECO
BTPS3 (08/05/2017)
Joint Failure
1
3
W/W
W/W W/W
BTPS4 (25/05/2017)
Erection Welding (02/12/2017)
Fatigue Failure
(09/01/2018)
SB Steam Errosion
3
Joint failure

4 W/W
(14/06/2017)
Ash errosion WWZ Panel + ECO
BTPS5 (04/12/2017)
Fatigue Failure
2
7
LTSH
CSTPS3 (25/10/2017)
Overheating
1
8
W/W RH W/W
CSTPS4
(30/04/2017)
Errosion due to
(16/06/2017)
Long term (26/07/2017)
Errosion
3
Falling of Clincker Overheating

9 ECO PSH
ECO (31/07/2017) (20/10/2017)
CSTPS5 (02/04/2017)
Old Welding Joint
Flue Gas Errosion Fretting
AOH CARRIED OUT FROM 01/11/17 TO 13/12/17 3
Failure

10
ECO
(21/10/2017) W/W
CSTPS6 ECO
(07/10/2017)
Concentrated Flue (28/12/2017) AOH STARTED FROM 01/02/20183
Gas Errosion Falling Slag Errosion
Concentrated Flue
Gas Errosion
11
CSTPS7
Works to be carried out in Overhaul 0
ECO ECO
W/W (03/10/2017) (24/10/2017) ECO W/W ECO + W/W
ECO
CSTPS8 (18/06/2017)
Steam Errosion
(11/08/2017)
Erection Joint Failure Erection Joint Failure (12/11/2017)
Erection Joint
(27/11/2017)
Erection Joint
(11/02/2018)
AOH from 16/12/17 to 02/02/18(Radiography of total
Welding 7 out)
Joint 464 joints of ECO carried
Erection Joint Failure Failure Failure
Failed
W/W
(05/10/2017) ECO
CSTPS9 Steam Errosion (03/11/2017)
Air Erosion
2
12
ECO
(17/12/2017) R/H SCW
KPKD1 Localised Flue Gas
Errosion
(31/12/2017)
Fretting
(20/01/2018)
Stress Rupture
3
12
KPKD2 0
12 ECO SCW ECO
(25/05/2017) (15/06/2017) ECO (29/08/2017) ECO
Localised Flue Gas Thermal Stress (12/07/2017) Localised Flue Gas (06/09/2017)
KPKD3 Errosion Rupture Localised Flue Gas
Errosion
Errosion Localised Flue Gas
Errosion
5
AOH started from 24/01/18 (ECO Coils replaced)

12
SCW
KPKD4 (16/04/2017)
Thermal Fatigue
ECO
(04/05/2017)
ECO
(26/06/2017)
ECO
(10/07/2017)
W/W
(13/07/2017)
COH from 3/08/17 to 5/10/17
ECO
(24/10/2017)
6
Localised Flue Gas Localised Flue Gas Localised Flue Gas Thermal Stress Old Welding Joint
Errosion Errosion Errosion Rupture Failure
12 W/W W/W
(06/05/2017) (26/05/2017) W/W S- panel
ECO Errosion + Errosion + ECO W/W W/W
KPKD5 (17/04/2017)
Flue Gas Errosion
Corrosion Corrosion (11/07/2017)
Thinning
(08/11/2017)
FG Errosion
(04/02/2018)
Welding Joint (11/02/2018)
Air Errosion
7
Failure

12
KTPS6 0
12 W/W ECO
ECO (31/05/2017) (03.09.2017)
KTPS7 (14/04/2017)
Ash Errosion
Steam Errosion Stress Rupture
3

KTPS8
W/W
(20/04/2017)
Steam Errosion
To PPT 1

W/W
KTPS9 (13/11/2017)
Overheating
1
W/W
W/W (03/05/2017) R/H
KTPS10 (25/04/2017)
Steam Errosion
Short Term
Overheating
(29/11/2017)
Steam Errosion
3
20

R/H
NTPS3 R/H
(01/07/2017)
(27/12/2017)
(Stress Rupture- 2
Roof tube erection Erection weld fail)
attachment weld
failure
21
W/W
NTPS4 (18/12/2017)
SB Steam Errosion)
1
22
PSH W/W
NTPS5 (16/11/2017)
Overheating
(06/01/2018)
SB Steam Errosion
2
23
ECO
PARAS3 (21/01/2018)
Welding Joint 1
Failure

24
ECO
PARAS4 (03/04/2017)
Flue Gas Errosion
1
26
PTPS4 0
27
PTPS5 0
28
PTPS6 0
29
W/W
PTPS7 (07/04/2017)
Ash Errosion
1

W/W W/W
PTPS8 (16/04/2017) (24/11/2017)
Overheating
2
Monthly Total 10 8 5 7 2 2 8 8 7 4 3
64
Cumulative
Total 10 18 23 30 32 34 42 50 57 61 64

Você também pode gostar