Você está na página 1de 1

CONTROLLER INSTRUCTIONS

5-2. FUNCTION TABLE

No Function Controlled Description


Part
1-1 Temperature Compressor 1. The temperature can be changed by turning the dial knob.
Control Evap. Fan Motor 2. Compressor is automatically turned on and off by thermostat.
(GNF-105D-01A) Cond. Fan Motor ■ Cut in and out temperature chart.
Model: TUR-28SD
No. Cool Normal Cold
TUR-48SD
TST-48SD Cut in 41 38.3 36.5
Cut Out 19.4 15.8 13.1

1-2 Temperature Compressor 1. The temperature can be changed by turning the dial knob.
Control Evap. Fan Motor 2. Compressor is automatically turned on and off by thermostat.
(GNF-105D-04A) Cond. Fan Motor ■ Cut in and out temperature chart.
Model: TST-28SD
No. Cool Normal Cold
Cut in 41 38.3 36.5
Cut Out 16.7 13.1 9.5

1-3 Temperature Compressor 1. The temperature can be changed by turning the dial knob.
Control Cond. Fan Motor 2. Compressor is automatically turned on and off by thermostat.
(GNF-106D-06A)
■ Cut in and out temperature chart.
Model:
TUF-28SD,48SD No. Cool Normal Cold
Cut in 3˚F -1˚F -3˚F
Cut Out -9.5˚F -13˚F -15˚F

3. When the door opened, the evaporator fan motor stop and lamp turn on.

2 Defrost Compressor 1. Defrost function is not in this model.


Function Evap. Fan Motor 2. When the compressor is turned off, the
(Off Cycle) Cond. Fan Motor ‘natural defrost function’ is started.
Model: TUR-28SD ■ Natural defrost step
TUR-48SD
TST-28SD Comp EVA.-fan CON-fan
TST-48SD Off On Off

3 Defrost Compressor 1. If it reaches defrost cycle time, the defrost heater comes on.
Function Evap. Fan Motor 2. Defrost function terminates when D-sensor’s temperature gets to above 48.2˚F
Model: TUF-28SD Cond. Fan Motor (9˚C).
TUF-48SD
3. Defrost step
Defrost Pause
Comp Off Off
F-fan Off Off
C-fan Off Off
Heater On Off
Max time - 9 min

18

Downloaded from www.Manualslib.com manuals search engine