We are experts on how to make savings on installation costs and how expensive follow-
up costs can be saved. HUBER+SUHNER implements future-proof passive cable network
infrastructures which are compatible with all system vendor products and endure the
future generations of active equipment.
Mobile operators on three continents verified that MASTERLINE Extreme Hybrid can be
installed in approximately half of the time of competitive hybrid solutions based on corru-
gated coax cable designs.
The factory-terminated "plug & play" system in combination with a highly flexible and
easy-to-route cable makes the HUBER+SUHNER solution the hybrid cable of choice for
operators, system vendors and installers alike.
Tower mast solution for RRH Standard cable length Low inductance cable length
up to 400 ft. 10 thru 1000 ft.
LISCA RF jumpers
page 28
LC patchcord
page 34
Shelter cables/accessories
page 34
Rooftop solution for RRH Rooftop corners supplied with Standard cable length
MLCH 2/4 or 4/8 assemblies up to 400 ft.
Low inductance 10 thru 1000 ft.
MLCH 2/4,4/8, 6/12 Large HTTA box/6 RRH with OVP LISCA RF jumpers
page 13 – 22 page 7 page 28
Shelter cables/
accessories
page 34
MLCH 6/12 Sector HTTA box/for 2 or 6 RRH HTTA hybrid jumper 1/1, 1/2
page 22 page 7 page 24
Plenum cable and rise options are available upon request. Full hardware line available.
Rooftop solution with in-building Rooftop box (without OVP) Standard cable length
base station for RRH to distribute cables to up to 400 ft.
remote radios Low inductance 10 thru 1000 ft.
LISCA RF jumpers
page 28
MLCH 6/12
page 22
Shelter cables/accessories
page 37
Specifications
Small HTTA box Large HTTA box Rack mount OVP Rack mount OVP –
front access
Number of RRHs 2 RRHs 6 RRHs 6 RRHs 6 RRHs
Overvoltage protection class 1 class 1 or without SPD class 1 class 1
Number of fiber optic ports 4 × LC duplex adapters 12 × LC duplex adapters none none
Number of termination blocks 2 power pairs 6 power pairs 6 power pairs 6 power pairs
(power) and grounding and grounding and grounding and grounding
Dimensions 10.15 × 8.15 × 13.58 15.73 × 10.25 × 19.18 19 inches rack unit 19 inches rack unit, 4RU
(width × depth × height) inches inches
Weight 14 lbs (6.35 kg) 32 lbs (14.51 kg) with SPD 15.25 lbs 20 lbs (9.1 kg)
26 lbs (11.80 kg) without SPD fully loaded
Environmental rating IP67 indoor indoor
Operating temperature −40 to +80 °C −40 to +85 °C −40 to +85 °C
UV resistant yes indoor indoor
Pressure equalizing vent Gore™ Vent NA NA
Combined wind loading 150 mph (sustained): 200 lbs (889.6 N) NA NA
Electrical specifications
Nominal operating voltage 48 V DC
Nominal discharge current (In) 20 kA 8/20 μs
Maximum surge current (Imax) 60 kA 8/20 μs
Maximum impulse (lightning) 5 kA 10/350 μs
current per IEC 61643-1
Maximum continuous operating 75 V DC
voltage (Uc)
Voltage protection rating (VPR) 400 V
per UL 1449
Protection class as per class I
IEC 61643-1
SPD alarm upon sacrifice
Intrusion sensor microswitch NA NA
Moisture sensor infrared moisture detector NA NA
For RHSDC-4750
Assembled in unit as shipped
Pos. Connector size Insert qty Insert P/N Insert range (mm) Cable (mm) Cable type
C C
A M75 1 190-0620 37 to 40 38.9/39.4 6/12 #6/6/12 LIC #6
B
B M75 2 190-0644 26 to 29 27.2/27.6 2/4 #6/2/4 LIC #6
B A
C M63 2 190-0643 26 to 29 27.2/27.6 2/4 #6/2/4 LIC #6
Included in kit as shipped with unit
Pos. Connector size Insert qty Insert P/N Insert range (mm) Cable (mm) Cable type
A M75 2 190-0644 26 to 29 27.2/27.6 2 × 4 #6/2 LIC #6
B M63 2 190-0643 26 to 29 27.2/27.6 2 × 4 #6/2 LIC #6
A&B M75 3 190-0661 30 to 33 33.0 4/8 #6
C M63 2 190-0660 30 to 33 33.0 4/8 #6
For RHSDC-1064
Assembled in unit as shipped
Pos. Connector size Insert qty Insert P/N Insert range (mm) Cable (mm) Cable type
A M63 1 190-0643 26 – 29 27.2 2/4 #6
B 27.6 2/4 LIC #6
A
B M40 2 190-0638 19 – 22 20.78 1/1 1/2
B Included in kit as shipped with unit
Pos. Connector size Insert qty Insert P/N Insert range (mm) Cable (mm) Cable type
A M63 1 190-0660 30 – 33 33.0 4/8 #6
10.1510.15 10.15
257.90
257.90 257.90
13.58
13.58
13.58
345
345
345
60.26 8.158.15 8.15
60.26
60.26
207.02
207.02 207.02
2.37
2.37
Large HTTA box for 6 RRHs Front Front Front 2.37 Side Side Side BottomBottom Bottom
487.20
487.20
19.18
19.18
19.18
583.70
583.70
583.70
22.98
22.98
22.98
651.76
651.76
651.76
25.66
25.66
25.66
7.7
0.30
482.6
19.00 DETAIL A
SCALE 1 : 2
7.7
0.30 36.3
7.7
0.30
52.1
36.3
1.43
132.9
5.23
A
2.05 64.8
2.55 80.7
3.18
109.3
4.30
52.1
64.8 346.4
2.05 13.64
2.55 80.7
3.18
109.3
440.0 4.30
17.32
482.6
19.00 DETAIL A
SCALE 1 : 2
440.0
17.32
132.9
5.23
482.6
19.00 A DETAIL A
SCALE 1 : 2
346.4
13.64
132.9
5.23
A
Rack mount front access OVP 5.5
0.22
37.2
1.47
484.6
19.08
49.9 440.0
57.9 17.32
1.97
2.28
346.4
13.64
118.1
126.1
4.65 138.8
4.97
5.47
170.6
6.72
176.5
B 6.95
DETAIL B
SCALE 1 : 2
Glandkit description
Quantity H+S Item no. Insert P/N Product description
2 85016047 190-0621 insert, M75, 3H, 22 m
HS_PrimaryA_GlandKit-1
2 190-0638 insert, M40, 1H, 22 m
1 190-0711 insert, M40, 1H-12 mm, 2H-6.3 mm
1 100-1286 RHSDC-3315-PF-48 discrete cable-gland insert kit
8 190-0538 plug, 18.3-23.8 mm, tapered EPDM
1 190-0517 plug, 9 to 14 mm, tapered EPDM
2 190-0516 plug, 5 to 8.5 mm, tapered EPDM
2 85016049 190-0662 insert, M75, 1H, 38 m
HS_PrimaryA_GlandKit-2
2 190-0683 insert, M63, 1H, 27.5 m
2 190-0684 insert, M75, 1H, 27.5 m
2 190-0590 plug, 32 to 39 mm, tapered EPDM
4 190-0705 plug, 23.8 to 27.9 mm, tapered EPDM
Specifications
Temperature range −40 to +75 °C (wet)
UV resistance (assembly and pulling tube) yes
Ingress protection pulling tube IP67
Pulling force (tube) 80 lbs horizontal
common drain
wire
-48V Power
Conductors
0V Power
Conductors
Alarm Pairs
Specification
UL listing tray cable (type TC-ER)
Conductors class C stranded, 6AWG
Minimum bending radius 12 × outer diameter
Cold bending −40 °C passed
Vertical flame test FT4 passed
Color coding alarm wire
2 × 4 – 5 pairs 18 AWG twisted pairs
6 × 12 – 9 pairs 18 AWG twisted pairs
×2 violett ×2 violett
×3 green
×4 brown
×5 yellow
×6 white
Specification
UL listing TC-OF-ER 600V
Inner Conductors class G stranded, 6 AWG
Outer Conductors class C stranded, 6 AWG
Minimum bending radius 12 × outer diameter
Cold bending −40 °C passed
Vertical flame test FT4 passed
Color coding alarm wire
2/4 - 5 pairs 18 AWG twisted pairs
6/12 - 9 pairs 18 AWG twisted pairs
300 85016667 tba H+S_MLC-Hybrid 6x12 Low Inductance (6 AWG)SM-LCDx12_300 ft 555 617.8
310 85021075 tba H+S_MLC-Hybrid 6x12 Low Inductance (6 AWG)SM-LCDx12_310 ft 573.5 636.3
320 85030078 tba H+S_MLC-Hybrid 6x12 Low Inductance (6 AWG)SM-LCDx12_320 ft 592 654.8
330 85016187 tba H+S_MLC-Hybrid 6x12 Low Inductance (6 AWG)SM-LCDx12_330 ft 610.5 673.3
340 85021074 tba H+S_MLC-Hybrid 6x12 Low Inductance (6 AWG)SM-LCDx12_340 ft 629 691.8
350 85030079 tba H+S_MLC-Hybrid 6x12 Low Inductance (6 AWG)SM-LCDx12_350 ft 647.5 710.3 Ø 39.4 × 39.4 inch
(Ø 1000 × 1000 mm)
360 85016669 tba H+S_MLC-Hybrid 6x12 Low Inductance (6 AWG)SM-LCDx12_360 ft 666 728.8
370 85016608 tba H+S_MLC-Hybrid 6x12 Low Inductance (6 AWG)SM-LCDx12_370 ft 684.5 747.3
380 85030080 tba H+S_MLC-Hybrid 6x12 Low Inductance (6 AWG)SM-LCDx12_380 ft 703 765.8
390 85016671 tba H+S_MLC-Hybrid 6x12 Low Inductance (6 AWG)SM-LCDx12_390 ft 721.5 784.3
400 85016004 tba H+S_MLC-Hybrid 6x12 Low Inductance (6 AWG)SM-LCDx12_400 ft 740 802.8
410 85030081 tba H+S_MLC-Hybrid 6x12 Low Inductance (6 AWG)SM-LCDx12_410 ft 758.5 821.3
420 85016672 tba H+S_MLC-Hybrid 6x12 Low Inductance (6 AWG)SM-LCDx12_420 ft 777 839.8
430 85016663 tba H+S_MLC-Hybrid 6x12 Low Inductance (6 AWG)SM-LCDx12_430 ft 795.5 858.3
440 85030082 tba H+S_MLC-Hybrid 6x12 Low Inductance (6 AWG)SM-LCDx12_440 ft 814 876.8
450 85016673 tba H+S_MLC-Hybrid 6x12 Low Inductance (6 AWG)SM-LCDx12_450 ft 832.5 895.3
460 85016665 tba H+S_MLC-Hybrid 6x12 Low Inductance (6 AWG)SM-LCDx12_460 ft 851 913.8
470 85030083 tba H+S_MLC-Hybrid 6x12 Low Inductance (6 AWG)SM-LCDx12_470 ft 869.5 932.3
480 85016674 tba H+S_MLC-Hybrid 6x12 Low Inductance (6 AWG)SM-LCDx12_480 ft 888 950.8
490 85016668 tba H+S_MLC-Hybrid 6x12 Low Inductance (6 AWG)SM-LCDx12_490 ft 906.5 969.3
500 85030084 tba H+S_MLC-Hybrid 6x12 Low Inductance (6 AWG)SM-LCDx12_500 ft 925 987.8
510 85016676 tba H+S_MLC-Hybrid 6x12 Low Inductance (6 AWG)SM-LCDx12_510 ft 943.5 1006.3
520 85016670 tba H+S_MLC-Hybrid 6x12 Low Inductance (6 AWG)SM-LCDx12_520 ft 962 1024.8
530 85030085 tba H+S_MLC-Hybrid 6x12 Low Inductance (6 AWG)SM-LCDx12_530 ft 980.5 1043.3
540 85016189 tba H+S_MLC-Hybrid 6x12 Low Inductance (6 AWG)SM-LCDx12_540 ft 999 1061.8
550 85016188 tba H+S_MLC-Hybrid 6x12 Low Inductance (6 AWG)SM-LCDx12_550 ft 1017.5 1080.3
560 85030086 tba H+S_MLC-Hybrid 6x12 Low Inductance (6 AWG)SM-LCDx12_560 ft 1036 1098.8
570 85016780 tba H+S_MLC-Hybrid 6x12 Low Inductance (6 AWG)SM-LCDx12_570 ft 1054.5 1117.3
580 85016675 tba H+S_MLC-Hybrid 6x12 Low Inductance (6 AWG)SM-LCDx12_580 ft 1073 1135.8
590 85030087 tba H+S_MLC-Hybrid 6x12 Low Inductance (6 AWG)SM-LCDx12_590 ft 1091.5 1154.3
600 85016781 tba H+S_MLC-Hybrid 6x12 Low Inductance (6 AWG)SM-LCDx12_600 ft 1110 1172.8
610 85016677 tba H+S_MLC-Hybrid 6x12 Low Inductance (6 AWG)SM-LCDx12_610 ft 1128.5 1191.3
700 85016191 tba H+S_MLC-Hybrid 6x12 Low Inductance (6 AWG)SM-LCDx12_700 ft 1295 1357.8
800 85016795 tba H+S_MLC-Hybrid 6x12 Low Inductance (6 AWG)SM-LCDx12_800 ft 1480 1542.8 Ø 66.9 × 35.4 inch
900 85030088 tba H+S_MLC-Hybrid 6x12 Low Inductance (6 AWG)SM-LCDx12_900 ft 1665 1727.8 (Ø 1700 × 900 mm)
1000 85030089 tba H+S_MLC-Hybrid 6x12 Low Inductance (6 AWG)SM-LCDx12_1000 ft 1850 1912.8
Specifications
Temperature range −40 to +75 °C
Operating voltage 48 V DC
Rated voltage 0.6 kV/1 kV
Ericsson Nokia (cable gland included)
Fiber (radio end) FullAXS connector LC duplex connector
Power (radio end) blunt-cut blunt-cut
(compatible to Amphenol power connector)
Fiber (HTTA box) LC duplex connector
Power (HTTA box) blunt-cut
Specifications
Electrical conductors class C stranded, 10 AWG
Fiber optic 2 × Ø 4.8 mm riser cable 2 singlemode fibers (total 4 fibers)
Outer diameter 0.82 inch (20.8 mm)
Weight 0.314 lb/ft (0.467 kg/m)
Minimum bending radius 15 × outer diameter
UV resistance UL 1581
Cold bending −40 °C passed
Conductor color code 1 (black), 2 (white)
FullAXS LC duplex
Compatible to 10 AWG
RRH connector power pair
2 × FullAXS
2 × LC duplex
Compatible to Compatible to
RRH connector RRH connector
LC duplex LC duplex
10 AWG 10 AWG
power pair power pair
2 × LC duplex 2 × LC duplex
10 AWG 10 AWG
power pair power pair
FullAXS adapter
Item no. Description Picture
85005377 Full AXS shower hose adapter
1)
LTE = Long Term Evolution 2)
special marking on cable
Ground bars, hangers, see HUBER+SUHNER hardware catalog see HUBER+SUHNER hardware catalog
hardware kits, cold shrink
fiber overlength box, 1RU, with 19 – 23" adapter bracket 85021721
MASTERLINE Classic (MLC) 12 fiber, 6 RRH LC/LC outdoor cable assemblies with 7.0 mm cable
Ordering information
Description Fiber type Length (m) Item no.
LC uniboot patchcord singlemode 0.5 84138001
0.7 84125518
1.0 84125519
1.5 84138003
3.0 85030874
Technical data
Electrical data
Impedance 50 Ω
Frequency range Dependent on connector interface
Environmental data
Operating temperature −40 to +85 °C
PIM rating (PIM adaptors only) static −165 dBc at 2 × 43 dBm/20 W carrier
2011/65/EU (RoHS) compliant
Mechanical data
Number of matings 500 matings for 7/16, N, 4.3/10 and 4.1/9.5 (dependent on each connector’s recommended torque). Increased
torque above the recommended value may reduce the number of matings significantly.
AUX components
Adaptor, QMA female to SMA female 84017911 34_QMA-SMA-50-1/133_NE
Adaptor, SMA female to 1.0/2.3 C50 female 22652962 31_SMA-1023-C50-1/111_NE
Adaptor, 1.0/2.3 C50 male to SMA female 22652963 33_1023-SMA-C50-1/111_NE
Adaptor, N-precision male to 4.3/10 female 85017232 33_N-4310-50-1/133_NE
Adaptor, PC 3.5 mm male to 4.3/10 female 85017256 33_PC35-4310-50-1/1-9_NE
Adaptor, 4.3/10 male to N-precision female 85017229 33_4310-N-50-X1/133_NE
Adaptor, 4.3/10 male to PC 3.5 mm female 85017252 33_4310-PC35-50-X1/133_NE
Test cable
TL-P test cable, 7/16 male to 7/16 male, 3 m 85027254 TL-P-11716-11716-03000-51
Specifications
Code compliance NFPA 70, the National Electrical Code
Section 300.22(c)(1), suitable for use in other spaces used for environmental air (plenums)
Section 330.17, through or parallel to framing members
UL approved • UL/NEC TC-OF, MC (without a non-metallic covering)
• UL 1581 vertical tray flame test (70 000 BTU/hr)
• CSA FT4 flame resistance
The insulation is suitable for use in 90 °C dry and 75 °C wet locations.
Rated for −25 °C cold bend, successfully tested to −40 °C cold bend.
Uses permitted • Services, feeders, and branch circuits
• Power, lighting, control, and signal circuits
• Indoors or outdoors
• Exposed or concealed
• In cable tray
• In any raceway
• As an aerial cable on a messanger
Passive DAS
DAS technology
A Passive DAS is a system in which the signal combining and distribution of various RF
signals technology wise is only based on passive RF components. This approach is often
used in small or medium sized buildings.
Active DAS
In an Active DAS, the RF signals are amplified on the downlink on their way from the
signal source to the antenna as well as on the uplink from the antenna to the receiver.
Fiber optic technology is often deployed to bridge longer distances and thus considered
the most economical solution in large active DAS projects.
Mechanical data
Cable types Cable attenuation Jacket diameter Bending radius
Sucoform 141 LA Cu CMP 0.61 dB/m @ 2.7 GHz 4.20 mm min. 8 mm
Sucoform 222 LA Cu CMP 0.41 dB/m @ 2.7 GHz 6.20 mm min. 25 mm
Connector types
Connector types Male straight Male angle Female straight
DIN 7/16 X X X
DIN 4.1/9.5 X X X
N X X X
4.3-10-X (HEX. Nut) X X X
SMA X X X
QMA X
Technical data
Technical data
Frequency range DC up to 6 GHz
Return loss Frequency Straight/straight Straight/angle
0.38 to 1.0 GHz ≥ 29 dB ≥ 28 dB
up to 2.2 GHz ≥ 27 dB ≥ 25 dB
up to 2.7 GHz ≥ 26 dB ≥ 24 dB
up to 3.8 GHz ≥ 23 dB ≥ 20 dB
up to 6 GHz ≥ 20 dB ≥ 19 dB
PIM performance ≤ 160 dBc typical —165 dBc
at 1.8GHz 2x 43dBm (QMA: ≤ 140 dBc)
Environmental data
Environmental data
Temperature range —40 to 105 °C
Waterproof IP67 (0.5 m/1 h/20 °C)
Cable performance UV resistance
UL444/CMP/FT6, ETL listed
Jacket colour: white
Further information 100 % tested for return loss, attenuation and PIM
Serial product label on each jumper for tracking
Stock items in lengths of 0.5 up to 5 m
1 2 3
List of components
Pos. Components Description
1 Cable SPUMA 240
2 Connector Push-pull 1.0/2.3 male plug
3 Connector 4.3-10 male plug (shown in drawing)
7/16 male plug
N male plug
SMA male plug
QMA male plug
Mechanical data
Property Description Value
Cable Ø outer jacket 6.15 mm
Bending radius static 19 mm min.
Coupling nut torque 4.3-10 male plug (hex nut) 5 to 8 Nm (recommended)
7/16 male plug 25 to 30 Nm (recommended)
N male plug 2 to 3 Nm (recommended)
SMA male plug 0.8 to 1.1 Nm (recommended)
QMA male plug n/a
Electrical data
Property Description Value
Impedance 50 ohms
Frequency 6 GHz
Attenuation @ 2 GHz, 25 °C dB/meter (cable only) 0.39
Environmental data
Property Description Value
Temperature range operating −40 to 85 °C
RoHS (2011/65/EU) compliant
www.wireless-infrastructure.com
HUBER+SUHNER is certified according to EN(AS) 9100, ISO 9001, ISO 14001, ISO/TS 16949 and IRIS.
Waiver
Fact and figures herein are for information only and do not represent any warranty of any kind.