Você está na página 1de 18

ACCESSORIES

EXTENSION CABLE OPTIONS

Cable length limitations (Based on published Bus and Serial Communications Standards)

Apply good industry practices for long cable runs - keep cable away from high power AC lines and all motor drive cables.

R-Series sensor models Baud rate Maximum cable or bus length G-Series sensor models Maximum cable length
1.5 MBd 10 ft. (3 m) G-Series Analog (Voltage or Current) 150 ft. (45 m) -
R-Series SSI
400 kBd 160 ft. (50 m)
G-Series digital (PWM or Start/Stop) 300 ft. (90 m) Note 1
300 kBd 320 ft. (100 m)
200 kBd 650 ft. (200 m) G-Series Neuter
100 kBd 1300 ft. (400 m) 250 ft. (75 m) Note 2
(Start/Stop output wired for square wave neuter)

Accessories
1.0 MBd 80 ft. (25 m)
500 kBd 320 ft. (100 m)
R-Series CANbus
250 kBd 820 ft. (250 m)
Notes:
125 kBd 1640 ft. (500 m) 1. 300 feet maximum using the ± differential pair for the interrogation
(Start) and gate (Stop) signals.
500 kBd 420 ft. (130 m)
2. 250 feet maximum using single-ended interrogation (Start) signal.
R-Series DeviceNet 250 kBd 800 ft. (270 m)
The unused interrogation signal MUST be terminated to ground at the
125 kBd 1730 ft. (530 m)
control box.
12 MBd 330 ft. (100 m)
1.5 MBd 650 ft. (200 m)
R-Series Profibus 500 kBd 1300 ft. (400 m)
187.5 kBd 3280 ft. (1000 m)
≤93.75 kBd 3940 ft. (1200 m)

MTS Sensors 75 Temposonics® Linear-Position Sensors Product Catalog 551075 C


EXTENSION CABLE OPTIONS - HOW TO ORDER

Standard 6-pin connector type (D60) used with R-Series G-Series and E-Series Sensors

D
1 2 3 4 5 6 7 8

SENSOR CONNECTION TYPE (1-2)


D6 = Female connector, (straight exit), and standard #530026 Cable (PVC jacket) for sensors with D6 or D60 connector
DA = Female connector, (90° exit), and standard # 530026 cable (PVC jacket) for sensors with D6 or D60 connector.
DJ = Female connector, (straight exit) and # 530045 cable, (black polyurethane jacket for higher resistance to moisture and oil), for sensors with D6 or D60 connector.
DK = Female connector, (90° exit), and #530045 cable, (black polyurethane jacket for higher resistance to moisture and oil), for sensors with D6 or D60 connector.

CABLE LENGTHS* (3-5)


For standard length cables up to 100 ft.
005 = 5 ft.
015 = 15 ft.
Accessories

025 = 25 ft.
050 = 50 ft.
100 = 100 ft.
_ _ _ = Cable length (ft)*

CABLE TERMINATION (2 or 3 characters depending on option selected) (6-8)


Type DJ

P0 = Pigtail connection, (no connector)


D6M = D6 male connector, (Straight exit). Only available with the D6 option above.
D6 F = Female connector, (straight exit). Only available with the D6 option above.
DAF = Female connector, (90° exit). Only available with the DA option above.
Type DK
* Refer to “Cable Length Limitations” table on page 75 for maximum cable length.

6-pin connector type (D63) used with R-Series Profibus Sensors

D
1 2 3 4 5 6 7 8

SENSOR CONNECTION TYPE (1-2)

DF = Female connector, (straight exit), and #530040 cable for Profibus sensors with D63 connector
DG = Female connector, (90° exit), and #530040 cable for Profibus sensors with D63 connector
Type DG
CABLE LENGTHS* (3-5)

For standard length cables up to 100 ft.


005 = 5 ft.
015 = 15 ft.
025 = 25 ft.
050 = 50 ft.
100 = 100 ft.
___= Cable length (ft)*

CABLE TERMINATION (2 or 3 characters depending on option selected) (6-8)

P0 = Pigtail connection, (no connector)


DFM = Male connector, (Straight exit). For daisy-chain connections of Profibus sensors with D63 connector. Only available with the DF option above.
DGM = Male connector, (90° exit). For daisy-chain connections of Profibus sensors with D63 connector. Only available with the DG option above.

* Refer to “Cable Length Limitations” table on page 75 for maximum cable length.

Temposonics® Linear-Position Sensors Product Catalog 551075 C 76 MTS Sensors


EXTENSION CABLE OPTIONS - HOW TO ORDER

Standard 7-pin DIN connector type (D70) used with R-Series SSI Sensors

D P O
1 2 3 4 5 6 7

SENSOR CONNECTION TYPE (1-2)

D7 = Female connector, (straight exit), and #530029 cable (high performance shielding, orange polyurethane jacket), for SSI sensors with D70 connector.
DR = Female connector, (90° exit), and #530029 cable (high performance shielding, orange polyurethane jacket), for SSI sensors with D70 connector.
DS = Female connector, (straight exit) and standard #530026 cable, (PVC jacket), for SSI sensors with D70 connector.
DT = Female connector, (90° exit), and standard #530026 cable, (PVC jacket), for SSI sensors with D70 connector.
DU = Female connector, (straight exit), and #530045 cable, (black polyurethane jacket), for SSI sensors with D70 connector.
DV = Female connector, (90° exit), and #530045 cable, (black polyurethane jacket), for SSI sensors with D70 connector.

CABLE LENGTHS* (3-5)

Accessories
For standard length cables up to 100 ft.
005 = 5 ft.
015 = 15 ft.
025 = 25 ft.
050 = 50 ft.
100 = 100 ft.
_ _ _ = Cable length (ft)*

CABLE TERMINATION (6-7)


Type D7
P0 = Pigtail connection, (no connector)

* Maximum cable length is dependent on the baud rate (refer to “Cable Length Limitations” table on page 75)

10-pin MS connector type (MS0) used with R-Series SSI and G-Series Sensors

M F P O
1 2 3 4 5 6 7

SENSOR CONNECTION TYPE (1-2)

MF = Female connector, (straight exit), and #530045 cable (black polyurethane jacket) for R-Series and G-Series sensors with MS0 connector.

CABLE LENGTHS* (3-5)

For standard length cables up to 100 ft.


005 = 5 ft.
015 = 15 ft.
025 = 25 ft.
050 = 50 ft.
100 = 100 ft.
_ _ _ = Cable length (ft)*

CABLE TERMINATION (6-7)

P0 = Pigtail connection, (no connector)

* Maximum cable length is dependent on the baud rate (refer to “Cable Length Limitations” table on page 75)

MTS Sensors 77 Temposonics® Linear-Position Sensors Product Catalog 551075 C


ADAPTER CABLE OPTIONS FOR REPLACING RETIRED SENSOR MODELS (Temposonics I, II & L-SERIES)

Product Dimension Application

Used when replacing Tempo II and model LH sensors that have integral RB connectors

Part no: 253243, -1, -2


Female straight exit D6 to -1 1 ft. cable length, standard For G-Series analog output sensors
male RB connection
adapter cables

-2 1 ft. cable length, standard For G-Series digital-pulse and neuter output sensors

Part no: 253244, -1, -2


Female straight exit D6 to male -1 5 ft. cable length For G-Series analog output sensors
RB connection adapter cables

-2 5 ft. cable length For G-Series digital-pulse and neuter output sensors
Accessories

Used when replacing Tempo II sensors that have integral RC connectors

Part no: 201612, -1, -2


Female straight exit D6 to male -1 1 ft. cable length, standard For G-Series analog output sensors.
RC connection adapter cables

-2 1 ft. cable length, standard for G-Series digital-pulse and neuter output sensors.

Used when replacing model LH sensors that have integral or in-line 10-pin MS connectors

Part no: 253245, -1, -2


Female straight exit D6 to male -1 1 ft. cable length, standard For G-Series analog output sensors.
MS connection adapter cables

-2 1 ft. cable length, standard For G-Series digital-pulse and neuter output sensors.

Part no: 253246, -1, -2


Female straight exit D6 to
-1 5 ft. cable length For G-Series analog output sensors
male MS connection adapter
cables

-2 5 ft. cable length For G-Series digital-pulse and neuter output sensors

Used when replacing Tempo II and model LH sensors that have in-line MS connectors wired for the R1, R2, or R3 connection types

Part no: 253245-3


Female straight exit D6 to
For R3 connection using G-series digital-pulse output
male MS (R1, R2, or R3 -3 1 ft. cable length
sensors.
connection) adapter cables

Part no: 253246-3


Female straight exit D6 to
male MS (R1, R2, or R3
For R3 connection using G-series digital-pulse output
connection) adapter cables -3 5 ft. cable length
sensors.

Part no: 253302, -1, -2


Female straight exit D6 to For R1 (positive interrogation) connection using G-Series
-1 5 ft. cable length
male MS (R1, R2, or R3 sensors.
connection) adapter cables

For R2 (negative interrogation) connection using G-Series


-2 5 ft. cable length
sensors.

Temposonics® Linear-Position Sensors Product Catalog 551075 C 78 MTS Sensors


ADAPTER CABLE OPTIONS FOR REPLACING RETIRED SENSOR MODELS (Temposonics I, II & L-SERIES)

Product Dimension Application

Used when replacing models LH, LP and R-Series sensors that have integral RG connectors
Part no: 253248, -1, -2
For R-Series analog or G-Series analog and digital-pulse output
Female straight exit D6 to -1 1 ft. cable length, standard
sensors
male RG connection adapter
cables
For R-Series analog or G-Series analog and digital-pulse output
-2 5 ft. cable length
sensors

Part no: 253315, -1, -2


Female straight exit D7 to -1 1 ft. cable length, standard For R-Series SSI output sensors
male RG connection adapter
cables

-2 5 ft. cable length For R-Series SSI output sensors

Accessories
Used when replacing model LP sensors that have the integral C-style connector or in-line H or J style connectors

Part no: 253247, -1, -2, -3, -4


Female straight exit D6 to male AMP connection adapter cables. -1 1 ft. cable length For G-Series analog output sensors

-2 1 ft. cable length For G-Series digital-pulse output sensors

-3 7 ft. cable length For G-Series analog output sensors

-4 7 ft. cable length For G-Series digital-pulse output sensors

Product Dimension Application


Part no. 401327
Male RC to female RB For retrofitting RC connection style Temposonics II or model
connector adapter. 6 in. overall length
LH sensors

CONNECTORS (For current production sensors)

Product Dimension Material Application

5-pin style connectors

Part no. 370375


D51 Field-installable connector
55m m(2.2in.)
Female, straight exit, for Model R-Series
20mm sensors with DeviceNet output
(0.8in.)

Part no. 370376 37 mm( 1.5in)


D51 Field-installable
connector
Female, 90° exit, for Model R-Series
41mm sensors with DeviceNet output
(1.6in.)

MTS Sensors 79 Temposonics® Linear-Position Sensors Product Catalog 551075 C


CONNECTORS (for current production sensors)

Product Dimension Material Application


6-pin style connectors
Part no. 560700 Housing: Zinc nickel Female, straight exit, mates
D6 Field-installable 54 mm plated to D60 connection type on
connector (2.13 in.) Termination: Solder R-Series, G-Series & E-Series
Contact insert: Silver sensors with six conductor
Ø 18 mm plated cable (STC09131D)
(0.71 in.) Cable clamp: PG7

Part no. 370372 Housing: Zinc nickel Male, straight exit


D6 Field-installable 54 mm plated
connector (2.13 in.) Termination: Solder
Contact insert: Silver
Ø 18 mm plated
(0.71 in.) Cable clamp: PG7

Part no. 370423 Housing: Zinc nickel Female, for Profibus sensors
Accessories

D6 Field-installable connector 54 mm plated w/PG9 strain relief (D63


(2.13 in.) Termination: Solder connection type). Also used
Contact insert: Silver to retrofit 10 conductor
plated Tempo II extension cables
Ø 18 mm
Cable clamp: PG9 (STC09131D06PG9)
(0.71 in.) Max. cable dia.: 8mm
Part no. 370427 Housing: Zinc nickel Male, for Profibus sensors
D6 Field- 54 mm plated w/PG9 strain relief (D63
installable (2.13 in.) Termination: Solder connection type)
connector Contact insert: Silver (STC09131H06PG9)
Ø 18 mm plated
(0.71 in.) Cable clamp: PG9
Max. cable dia.: 8mm

Part no. 560778 Housing: Zinc nickel Female, 90° exit, mates to
54 mm
D6 Field- plated D60 & Profibus D63
(2.13 in.)
installable Termination: Solder connection type on R-Series,
connector Contact insert: Silver G-Series & E-Series sensors
38 mm plated with six conductor cable
(1.5 in.) Cable clamp: PG9, (STC09131-6)
M16
Ø 19.5 mm Max. cable dia.: 8 mm
(0.77 in.)
Part no. 370460 54 mm Housing: Zinc nickel Male, 90° exit, for Profibus
Profibus D6 Field- (2.13 in.) plated sensors (D63 connection
installable connector Termination: Solder type) (STC09131-6P)
Contact insert: Silver
38 mm
plated
(1.5 in.)
Cable clamp: PG9
Ø 19.5 mm
Max. cable dia.: 8mm
(0.77 in.)

Part no. 252347* 48 mm Housing: Zinc nickel For use with Model RH, RP &
Profibus bus (1.9 in.) plated RF sensors, Male connector
terminator Termination: Solder type
18 mm Contact insert: Silver
* was 370419 plated
(0.7 in.)
(STA09131H06)
dia.
7-pin style connectors
Part no. 560701 Housing: Zinc nickel Female, Straight exit, mates
54 mm
D7 Field-installable connector plated to D70 connection type on
(2.13 in.)
Termination: Solder R-Series sensors. Connector
Contact insert: Silver has PG7 size strain relief for
Ø 18 mm plated standard cable.
(0.71 in.) Cable clamp: PG7 (STC09131D07)

Part no. 370516 Housing: Zinc nickel Female, straight-exit, mates


D7 Field-installable 54 mm plated to D7 connection type on
connector (2.13 in.) Termination: Solder R-Series SSI sensors.
Contact insert: Silver Connector has PG9 size
Ø 18 mm plated strain-relief for larger cable
(0.71 in.) Cable clamp: PG9 size, (STC09131D07PG9)
Max. cable dia.: 8mm

Part no. 560779 54 mm Housing: Zinc nickel Female, 90° exit, mates to D70
D7 Field-installable (2.13 in.) plated connection type on
connector Termination: Solder R-Series sensors
Contact insert: Silver (STC09131-7)
38 mm plated
Cable clamp: PG9, M16
(1.5 in.)
Max. cable dia.: 8 mm
Ø 19.5 mm
(0.77 in.)

Temposonics® Linear-Position Sensors Product Catalog 551075 C 80 MTS Sensors


CONNECTORS (for current production sensors)

Product Dimension Material Application

4-pin style connectors and cord sets


Part no. 370523 Housing: Zinc Male, for EtherCAT sen-
M12 Field-installable nickel plated sor (D56 connection
connector Termination: type)
Insulation dis-
53 mm placement
(2.09 in) max. 1 4 technology

(0.67 in.) dia.


17 mm

M 12
2 3

Accessories
Part no. 530064 Cable jacket: 2 male M12 connectors
5 meter industrial Ethernet Polyurethane (D-coded) for EtherCAT
cable (Cat 5e Es) with sensor (D56 connection
47 mm
2 4-pin M12 connectors Cable type)
(1.85 in.)

(0.63 in.) dia.


16 mm
Male M12
connector

Part no. 530065 Cable jacket: RJ 45 connector and


5 meter industrial Ethernet Polyurethane male M12 connector (D-
cable (Cat 5e ES) with 55 mm coded) for EtherCAT sen-
47 mm
RJ45 connector and M12 (2.17 in.) sor (D56 connector type)
(1.81 in.)
4-pin connector
(0.63 in.) dia.
16 mm

M12x1

RJ45
4-pin M12 Cable
connector

Part no.530066 Cable jacket: Female M8 connector,


5 meter power cable Polyurethane cable with pigtail termina-
M8 x 1
with M8 connector tion for EtherCAT sensor
24 Vdc input power (D56
10 mm connector type)
(0.39 in.)
dia. 32.5 mm
(1.28 in.)

MTS Sensors 81 Temposonics® Linear-Position Sensors Product Catalog 551075 C


CONNECTORS (for current production sensors)

Product Dimension Material Application

5-pin style connectors


Part no. 560887 70 mm
(2.75 in.)
Housing: Zinc nickel T type connection for
M12 T-connector plated Profibus sensors (D53 con-
40 mm
(1.58 in.) 9 mm nection type)
(0.36 in.)

41 mm
(1.6 in.)

3 mm
19 mm (1.15 in.)
(0.74 in.) dia.

Part no. 560885 Housing: Zinc nickel Female, straight exit, for
M12 Field-installable connector plated Profibus sensors (D53 con-
20 mm Termination: Solder nection type)
(0.77 in.) dia. Contacts: Silver
Accessories

57 mm plated
(2.24 in.)

Part no. 560884 Housing: Zinc nickel Male, straight exit, for
M12 Field-installable connector plated Profibus sensors (D53 con-
20 mm Termination: Solder nection type)
(0.77 in.) dia. Contacts: Silver
62 mm plated
(2.44 in.)

Part no. 560888 Housing: Zinc nickel Male, for Profibus sensors
43 mm
M12 Profibus bus terminator plated (D53 connection type)
(1.69 in.)
22 mm Contacts: Silver
(0.87 in) plated

16 mm 14 mm
(0.64 in.) (0.55 in.)
dia.

Part no. 370515 Housing: Zinc nickel Male, 90° exit, for Profibus
M12 Field-installable connector 54 mm plated sensors (D53 connection
(1.12 in.)
Termination: Solder type)
40 mm Contacts: Silver
(1.57 in.) plated

Part no. 370514 Housing: Zinc nickel Female, 90° exit, for Profibus
54 mm
M12 Field-installable connector plated sensors (D53 connection
(2.12 in.)
Termination: Solder type)
38 mm Contacts: Silver
(1.50 in.) plated

Part no. 560886 Housing: Zinc nickel Female, 90° exit, for input
M8 (4-pin) Field-installable connector 28 mm plated voltage for Profibus sensors
(1.1 in.) Termination: Solder (D53 connection type)
Contacts: Silver
12 mm plated
(0.47 in.) 12.5 mm
dia. (0.49 in.)

Part no. 370504 Housing: Zinc nickel Female, straight exit, for
M8 (4-pin) Field-installable connector 40 mm plated 24Vdc input power for
(1.58 in.) Termination: Solder Profibus sensors (D53 con-
12 mm Contacts: Silver nection type)
(0.58 in.) dia.
plated

Temposonics® Linear-Position Sensors Product Catalog 551075 C 82 MTS Sensors


CONNECTORS (for retired sensor models)

Product Dimension Material Application

Part no. 400755-3 Female field-installable, mates


RB/RC connector, Field-installable with sensor fitted with RB
64 mm (2.5 in.) connector or previous RC
design
27 mm
(1.1 in.)

Part no. 370486 Male, field-installable


RB connector 64 mm (2.5 in.) mates with
part no: 400755-3

27 mm
(1.1 in.)

Accessories
Part no. 401366 Female, straight exit
RG Field-installable connector 58 mm mates to RG connection type
on R-Series and L-Series
(2.28 in.)

19 mm
(0.75 in.)

Part no. 370391 Housing: Zinc nickel Female, straight exit, mates to
D8 Field-installable connector 54 mm plated D80 connection type on
(2.13 in.) Termination: Solder Model L Series
Contact insert: Silver
Ø 18 mm plated
(0.71 in.) Cable clamp: PG7

MTS Sensors 83 Temposonics® Linear-Position Sensors Product Catalog 551075 C


MAGNETS AND FLOATS

Product Dimension Material Application


Part no. 201542-2 Composite PA-Ferrite- For Model RH, GH
Standard ring magnet 4 Holes GF20
4 Holes each 4.3 Weight:
mm dia.Approx.
(0.17 in.)14g
each 4.3 mm dia. (0.17 in.) 90 º apartOperating
on 23.9 mm dia.
temperature:
90 º apart on 23.9 mm dia. (0.94 in.)-40 to +100°C
(0.94 in.)
ID: 13.5 mm (0.53 in.)
ID: 13.5 mm (0.53 in.) OD: 32.8 mm (1.29 in.)
OD: 32.8 mm (1.29 in.) Thickness: 7.9 mm (0.312 in.)
Thickness: 7.9 mm (0.312 in.)
Part no. 201553 PA 66-GF30 For Model RH, GH
Large open-ring Magnet slugs potted
1of2Holes
magnet 4.5mmdia.(0.177in.) with epoxy
120º apart on 41.3 mm dia.
(1.625in.) Weight: Approx. 26g
11.2mm(0.44in.)opening Operating temperature:
90 Cu t-out
-40 to +75°C
I.D.:15.9mm(0.625in.)
O.D.:63.25mm(2.49in.)
Accessories

Thickness:9.5mm(0.375in.)

Part no. 201554 PA 66-GF30 For Model RH, GH


Large ring magnet Magnet slugs potted
with epoxy
Weight: Approx. 35g
Operating temperature:
1of4Holes -40 to +75°C
each4.6mmdia.(0.182in.)
90 ap arton41.3mmdia.
(1.625in.)
I.D.:19.05mm(0.75in.)
O.D.:63.25mm(2.49in.)
Thickness:9.5mm(0.375in.)

Part no. 251298-2 28 mm For Model RH, RP, GH, GP,


Bar magnet (1.10 in.) EP
7.6 mm 19 mm
(0.30 in.) (0.75 in.)
S
20 mm
13 mm (0.80 in.)
N (0.52 in.)
Stainless-steel plate
(bonded to magnet, 2 Holes
both sides) 60° each 4 mm (0.17 in.) dia.
on 24 mm (0.94 in.) dia.
Part no. 251416-2 2 Holes Composite PA-Ferrite- For Model RP, RH, GH, GP,
Standard open-ring 60° each 4 mm (0.17 in.) dia.
25 mm GF20 EP
on1424mm
mm (0.94 in.) dia.
magnet (0.97 in.)Weight: Approx. 11g
(0.57 in.) Operating temperature:
25 mm
14 mm (0.97 in.) 21 mm -40 to +100°C
(0.57 in.) (0.81 in.)
21 mm I.D.: 13.5 mm (0.53 in.)
(0.81 in.) O.D.: 33 mm (1.29 in.)
Thickness: 8 mm (0.312 in.)
I.D.: 13.5 mm (0.53 in.) Operating temperature:
O.D.: 33 mm (1.29 in.) 14 mm (0.55o in.)
-40 o C to +100
Min. ID C
Thickness: 8 mm (0.312 in.)
Part no. 251447 Operating temperature:
14 mm 316L Stainless steel For Model RH, GH
o (0.55 in.) 51 mm (2.0 in.)
Magnet float -40 o C to +100Min.
C ID Spherical OD 720 kg/m3
Density:
53 mm Max. Pressure: 870 psi
(2.09 in.) 51 mm (2.0 in.) 3.4 mm (0.134 in.)
Spherical OD Weight: 42 ± 3g
53 mm
(2.09 in.) 3.4 mm (0.134 in.)

Specific Gravity: 0.70 approx.


Pressure: 870 psi max.

Specific Gravity: 0.70 approx.


Part no. 252182 Pressure: 870 psi max. 43 mm GFK, Magnet hard For Model RP, GP, EP
Captive-sliding magnet (1.69 in.) ferrite
14 mm 20 mm
(0.55 in.) (0.79 in.) Weight: Approx. 30g
Rotation: Operating temperature:
Vertical: 18°
Horizontal: 360° -40 to +75°C
24 mm
Ball-jointed arm, (0.95 in.)
M5 thread
40 mm
(1.58 in.)

Part no. 252183 GFK, magnet hard For Model RP, GP, EP
24 mm 43 mm
Captive-sliding (0.94 in.) (1.69 in.) ferrite Similar to (252182) but with
magnet 20 mm Weight: Approx. 30g extra length on the
(0.79 in.) Operating temperature: ball-jointed arm
Rotation:
Vertical: 18° -40 to 75° C
Horizontal: 360°
24 mm
Ball-jointed arm, (0.95 in.)
M5 thread
40 mm
(1.58 in.)

Temposonics® Linear-Position Sensors Product Catalog 551075 C 84 MTS Sensors


MAGNETS AND FLOATS

Product Dimension Material Application


Part no. 252184 57 mm GFK, magnet hard For Model RP, GP, EP
Captive-sliding magnet 14 mm (2.24 in.) ferrite
(0.55 in.) Weight: Approx. 30g
18° rotation Operating temperature:
24 mm
(0.95 in.) -40 to 75° C
Ball-jointed arm,
M5 thread
9 mm 40 mm
(0.35 in.) (1.58 in.)

Part no. 252887 For Model EP, EP2


Block magnet type L 19.5 mm 6 mm (0.24 in.)
(0.77 in.) 20 mm (0.79 in.)
11 mm (0.43 in.)

31 mm
4.3 mm 13.5 mm
(1.22 in.)
(0.17 in.) dia. (0.53 in.)

Accessories
Part no. 400533 Composite: PA-Ferrite For Model RH, GH
Small ring magnet Weight: Approx. 10g
Operating temperature:
-40 to +100° C

ID: 13.5 mm (0.53 in.)


O.D.: 25.4 mm (1.0 in.)
Thickness: 7.9 mm (0.312 in.)

Part no. 400633 Aluminum For Model RH, GH.


Magnet spacer 4 Holes Non-ferrous spacer for use
each 3.9 mm O.D. (0.15 in.) with standard ring magnet
90° apart on 23.9 mm O.D. (0.94 in.) (201542-2)
I.D. 14.3 mm (0.56 in.)
O.D. 31.8 mm (1.25 in.)
Thickness: 3.2 mm (0.125 in.)

Part no. 401032 Surface PA coated For Model RH, GH.


Small ring magnet Weight: Approx. 5g Not for multi-position
Operating temperature: measurement.
-40 to +100° C
ID: 13.5 mm (0.532 in.)
O.D.: 17.4 mm (0.685 in.)
Thickness: 7.9 mm (0.312 in.)
(For use with strokes
±1525 mm or 60 in.)

Part no. 401467 Composite: PA-Ferrite For Model RH, GH


Large ring magnet 3.4 mm A Operating temperature: Due to the thin wall geome-
(0.13 in.) 30 mm -40 to +100° C try of this magnet, a support
(1.18 in.) carrier is recommended if
used inside a hydraulic cylin-
der or pneumatic cylinder.

24 mm
A (0.95 in.)

Part no. 401468 Composite: PA-Ferrite For Model RH, GH


Large ring magnet 11 mm (0.43 in.) Operating temperature: Due to the thin wall geome-
-40 to +100° C try of this magnet, a support
A carrier is recommended if
O.D. 38.1 mm
used inside a hydraulic cylin-
(1.5 in.)
der or pneumatic cylinder.
.

A I.D. 33 mm
(1.3 in.)

MTS Sensors 85 Temposonics® Linear-Position Sensors Product Catalog 551075 C


MAGNETS, FLOATS, AND PRESSURE HOUSING

Compatibility Chart

Sensor Model
Magnet
Part no. Rod-style Profile-style
RH GH RP GP EP
201542-2 • •

201553 • •

201554 • •

201298-2 • • • • •

251416-2 • • • • •
Accessories

251447 (float) • •

252182 • • •

252183 • • •

252184 • • •

400533 • •

401032 • •

401467 • •

401468 • •

HOW TO ORDER

Pressure Housing (for use with Temposonics sensor models GH and RH only)

H H
1 2 3 4 5 6 7 8

HOUSING STYLE (3)

T= US customary threads, raised-faced hex


S= US customary threads, flat-faced hex
M= Metric threads, flat-faced hex

STROKE LENGTH (4-8)*

_ _ _ _ M = Millimeters (Encode in 5 mm increments)


or
_ _ _ . _ U = Inches and tenths (Encode in 0.1 in. increments)

* Limited to 1825 mm (72 in.)

Temposonics® Linear-Position Sensors Product Catalog 551075 C 86 MTS Sensors


MOUNTING FEET AND T-SLOT NUT

Product Dimension Material Application


Part no. 400802 9 mm 304 Stainless steel For use with Model RP, GP, EP
0.21 in. dia. (0.36 in.)
Mounting feet, through 4 holes 28 mm and ER sensors.
standard (1.1 in.)
2 mm 9 mm
(0.08 in.) (0.36 in.)
50 mm (1.97 in.)
304 SST
68 mm
(2.68 in.)
Width = 14.5 mm (0.57 in.)

Part no. 252004 9 mm Stainless steel with For use with Model RP, GP,
Mounting feet, 5 mm (0.196 in.) I.D. (0.36 in.) nylon washer's and and EP sensors. Provides
28 mm
insulated (1.1 in.) cloth tape on bottom electrical and mechanical
2 mm 9 mm
(0.08 in.) (0.36 in.) isolation.
50 mm (1.97 in.)
68 mm
(2.68 in)
Width = 14.5 mm (0.57 in.)

Accessories
Part no. 401602 M5 thread Nut for mounting RP and GP
Base channel T-slot nut sensors.

5 mm (0.20 in.)
T-Slot nut, M5 thread
(optional, sold separately)

MECHANICAL END CONNECTORS (FOR USE WITH TEMPOSONICS SENSOR MODELS RP, GP, EP AND ER)

Product Dimension Material Application


Part no. 401603 For use with captive-sliding
Joint-rod sleeve 27 mm magnets
(1.06 in.)
(1 in.)

M5 inside
thread

Part no. 9 mm For use with captive-sliding


401913* (0.35 in.) magnets
Ball-jointed 22 mm
(0.87 in.)
arm, straight
14 mm
(0.55 in.)
M5 threads

Rotation: 18˚
allowable

Part no. 251975 53 mm For use with Model ER


Stud end attachment (2.1 in.) sensors
Threaded rod
(1/4 - 28 UNF)

1/4 in. Jam nut

Mounting Hardware:
1/4 in. Hex nuts (2 pcs.)
14 mm (0.56 in.) O.D. washer

Part no. 402849 Stainless Steel This part can be


Thread adapter, used with Models EP,
10-32 male to M5 female Lock Washer GP, or RP captive-sliding
M5 x 0.8 10-32 UNF - 2A magnets when
retrofitting old LPS
8 mm model sensors that have
(0.31 in.) the old 252052 captive-
sliding magnet (with
13 mm 9 mm #10-32 male threads).
(0.5 in.) (0.35 in.)
13 mm
(0.5 in.)

MTS Sensors 87 Temposonics® Linear-Position Sensors Product Catalog 551075 C


MECHANICAL END CONNECTORS (FOR USE WITH TEMPOSONICS SENSOR MODELS RP, GP, EP AND ER)

Product Dimension Application


Part no. 253346 See Part no. 560444 Male 1/4-28 rod ends (2 pieces), plus special wrench for
Rod end kit (English) use with Model ER sensors.

Part no. 253347 See Part no. 561255 Male M6 rod ends (2pieces), plus special wrench for use
Rod end kit (Metric) with Model ER sensors.
Accessories

Part no. 560444 Male 1/4-28 for use with Model ER sensors.
Rod end attachment (English) 7 mm
(0.28 in.) 16 ° Misalign
Angle
9.5 mm
(0.37 in.)
1/4-28

6 mm
(0.24 in.)
25 mm
(1 in.)

19 mm
(0.74 in.)

40 mm
(1.57 in.)

Part no. 561255 7 mm Male M6 for use with Model ER sensors.


Rod end attachment (Metric) (0.28 in.) 16 ° Misalign
Angle
9 mm
(0.35 in.)
M6

6 mm
(0.24 in.)
22 mm
(0.87 in.)

19 mm
(0.75 in.)

36 mm
(1.42 in.)

OPTIONAL EXTENSION RODS (FOR USE WITH TEMPOSONICS SENSOR MODELS RP, GP, AND EP WITH CAPTIVE-SLIDING MAGNET ONLY)
Extension rod lengths Part no. Extension rod lengths Part no. Extension rod lengths Part no.
60.3 mm (2.375 in.) 401768-2 238.1 mm (9.375 in.) 401768-9 517.5 mm (20.375 in.) 401768-20
85.7 mm (3.375 in.) 401768-3 263.5 mm (10.375 in.) 401768-10 542.9 mm (21.375 in.) 401768-21
111.1 mm (4.375 in.) 401768-4 314.3 mm (12.375 in.) 401768-12 619.1 mm (24.375 in.) 401768-24
161.9 mm (6.375 in.) 401768-6 365.1 mm (14.375 in.) 401768-14 771.5 mm (30.375 in.) 401768-30
187.3 mm (7.375 in.) 401768-7 390.5 mm (15.375 in.) 401768-15 923.9 mm (36.375 in.) 401768-36
212.7 mm (8.375 in.) 401768-8 466.7 mm (18.375 in.) 401768-18 1076.3 mm (42.375 in.) 401768-42
1228.7 mm (48.375 in.) 401768-48
1533.5 mm (60.375 in.) 401768-60

Extension rod
Part no. 401768-XX
9.5 mm
15.2 mm (0.375 in.)
(0.60 in.)
(both ends) M5-0.8 thread bore
(both ends)

Temposonics® Linear-Position Sensors Product Catalog 551075 C 88 MTS Sensors


MISCELLANEOUS INSTALLATION HARDWARE

Product Dimension Material Application


Part no. 500015 3/4-16 in. UNC Stainless steel, nylon 3/4-16 UNF Nylon insert
Hex jam-nut insert locknut for use with model
RH and GH sensors with
style “T” or “S” housings.

Part no. 500018 M18 x 1.5 threads Stainless steel M18 x 1.5 nut for use with
Hex jam-nut models RH and GH sensors
with style “M” housing.

10 mm
(0.4 in.) ID
Part no. 560777 27 mm 10 mm 304 stainless steel For use with GH and RH
(1.06 in.) OD 5 (0.4
mm in.) ID

Accessories
Collar 27 mm (0.2 in.) pressure housings and float
(1.06 in.) OD 5 mm 251447.
(0.2 in.)

8-32 threads
9 mm 4 mm
8-32 threads (0.16 in.)
(0.34 in.) 4
9 mm 8 mm
mm
(0.34 in.) (0.16
(0.31 in.)
in.)
8 mm
Part no. 560315 (0.31 in.) Fluoroelastomer 75 ± Spare, for use with rod-style
O-Ring, for US 16 mm ± 0.23 mm 2 mm ± 0.08 mm 5 durometer sensor Models RH and GH.
customary flange (0.644 in. ± 0.009 in.) I.D. (0.087 in. ± 0.003 in.) With style “T” or “S”
with 3/4-16 UNF threads housing.

Part no. 560357 #6-32x7/8 Used to mount standard ring


Magnet mounting Stainless steel magnet part no: 201542-2
screws (4 required) or open ring
magnet part no: 251416-2
(2 required).

Part no. 402617 Used to install newer sensor


60 mm
Electronics 2.5 mm cartridges (GHB and RHB
(2.35 in.)
housing screw Hex socket models) into the old LH or
old RH sensor pressure
housings (2 required).
8-32 UNC - 2A
Part no. 401133 15 mm ± 0.2 mm 2 mm ± 0.08 mm Fluoroelastomer 75 ± Spare, for use with rod-style
0-Ring, for metric (0.60 in. ± 0.01 in.) I.D. (0.09 in. ± 0.003 in.) 5 durometer sensor Models RH and GH
flange with M18 x 1.5 with style “M’ housing.
threads.

Part no. 252916 Dimensions: 80 mm The box is used for EMC-


Profibus filter box (3.15 in.) long x 75 conformal feeding of 24 Vdc
mm (2.95 in.) wide x supply voltage into the
Bus 58 mm (2.28 in.) Profibus-DP hybrid cable.
Bus deep.

24 Vdc

MTS Sensors 89 Temposonics® Linear-Position Sensors Product Catalog 551075 C


SENSOR DISPLAY

Product Dimension Application

Part no. 251153 109.5 mm Meter for use with Start/Stop sensors
Temposonics Display Unit 7 mm (4.31 in.) only.
(0.275 in.)
(TDU-200)*
48 mm SIDE 45 mm FRONT 48 mm
(1.89 in.) (1.78 in.) (1.89 in.)

96 mm
(3.78 in.)
91 mm
(3.6 in.)

Note: BACK 45 mm
(1.78 in.)
*Product Specification 550178 and User’s Manual 550260.

POWER SUPPLY

Product Dimension Application


Accessories

Part no: 380009 100 mm x 165 mm x 50 mm. Standard power supply (110 Vac to 24
Sensor power supply Vdc/ 0.5 A) for use with sensors and
interface products.

SENSOR PROGRAMMING

Product Application

Part no. 253124 For adjusting null (setpoint 1) and span (setpoint 2) on R-Series analog
R-Series analog hand-held programmer sensors, (for single magnet versions only).
Sensor 24 V

Part no. 253408 For adjusting null (setpoint 1) and span (setpoint 2) on R-Series analog
R-Series analog cabinet programmer sensors, (for single magnet versions only). The programmer is designed for
snap-in mounting on standard 35 mm DIN rail. A “program/run” switch
allows the programmer to be permanately wired inside the control cabinet.

Part no. 253309 Interface converter box, power supply, PC software and cabling.
R-Series analog PC programming kit

Part no. 253310 Interface converter box, power supply, PC software and cabling.
R-Series SSI PC programming kit

Part no. 252173-D63 For field address programming of R-Series Profibus output.
R-Series Profibus node address
programmer

Part no.252173-D53 For field address programming of R-Series Profibus output.


R-Series Profibus programming acces-
sories

Part no. 252382-D62 For field address programming of R-Series CANopen sensors.
R-Series CANbus programming accessories

Temposonics® Linear-Position Sensors Product Catalog 551075 C 90 MTS Sensors


SENSOR PROGRAMMING

Product Application

Part no. 253294 For adjusting null (setpoint 1) and span (setpoint 2) on G-Series analog
G-Series analog hand-held programmer sensors.

Part no. 380078 For adjusting null (setpoint 1) and span (setpoint 2) on G-Series analog
G-Series infrared setpoint programmer sensors.

Accessories
Part no. 253311 Interface converter box, power supply, PC software and cabling.
G-Series analog PC programming kit

Part no. 253312 Interface converter box, power supply, PC software and cabling.
G-Series digital pulse PC programming kit

Part no. 401727 Can be used to check the sensors functions and to change the slave
Profibus master simulator address. Allows the magnet positions and diagnostic data to be read.

FIELD SETUP SOFTWARE

Product Application
Part no. 551033 Includes G-Series PC setup software (part no: 625060)* G-Series Palm OS
G-Series documentation and software CD software (part no: 625061)*, G-Series User’s Manual (part no: 550966)
Download software from www.mtssensors.com and additional documentation.

Part no. 551052 Includes R-Series PC setup software (part no: 625064)*, parameter files
R-Series documentation and software CD and product documentation.
Download software from www.mtssensors.com

Note:
* Download software from our website (www.mtssensors.com)

MTS Sensors 91 Temposonics® Linear-Position Sensors Product Catalog 551075 C


Accessories

Temposonics® Linear-Position Sensors Product Catalog 551075 C 92 MTS Sensors

Você também pode gostar