OPERATIONAL Why should you wear a self-contained breathing apparatus Because carbon
before entering the engine room after the fixed CO2 system has dioxide dilutes the
been discharged to combat a major fire? oxygen concentration
in the atmosphere
and may cause
asphyxiation.
What should you do when the alarm bell on a self-contained Immediately evacuate
breathing apparatus sounds? the contaminated
area
While donning the positive -pressure self-contained breathing Replace the defective
apparatus, you discover that the air cylinder pressure gage and gages with a new pair
the regulator pressure gage differ from each other by 500 psi. from the spare parts
Which of the listed action should you consider as appropriate? inventory.
To safely enter a closed compartment, where CO2 has been wear a self-contained
released from a fixed extinguishing system, you should_______. breathing apparatus
What is a major advantage of using a positive pressure type self- The speed with which
contained breathing apparatus? it can be put into
operation is around
45 seconds.
What is a major advantage of the demand-type self-contained The speed with which
breathing apparatus? it can be put into
operation is around
45 seconds.