Innovation & Expertise PVCu Soil and Waste Systems

Marley Plumbing & Drainage offer a comprehensive


range of soil and waste systems. Available with
a variety of jointing methods, Marley products
are manufactured to UK and European standards
and are designed for use on commercial and
residential projects.

PVCu soil & waste systems are available with


push-fit or solvent weld joints, offering a choice
of installation methods.

Product specification information


Key
This guide contains design and
installation information for Marley ABS = Acrylonitrile butadiene styrene
PVCu soil & waste drainage systems.
PVCu = Poly vinyl chloride un-plasticised
All documentation can be
downloaded from marleypd.co.uk PP = Polypropylene

BS EN ISO 9001:2008
BS EN ISO 14001:2004

Contents

4 Marley soil & waste systems 27 WC connectors


6 Solvent waste – PVCu 29 WC manifold system
8 Solvent waste – ABS 32 Design
10 Push-fit waste – PP 40 Installation data
12 Condense and Overflow system 47 Site work
14 Push-fit soil – PVCu 48 British & European Standards
19 Solvent soil – PVCu 49 Key
25 Accessories 51 Marley system solutions

2 | MARLEY PVC Soil & Waste MARLEY PVC Soil & Waste | 3
Life4 Marley Soil & Waste Systems
PVCu soil and waste systems HDPE soil

The PVCu soil system is available in 82, 110 and 160mm push-fit and solvent weld options incorporating The HDPE soil range is certified to BS EN 1519: 2000 (licence It is particularly suited for commercial applications or where
socketed and plain ended pipe. number KM 545820) An extension of the Marley soil & waste a product with high impact or abrasion resistance is required,
110 and 160mm pipe support components have been designed specifically to support horizontal portfolio, the HDPE range offers an alternative solution such as hospitals, hotels, schools, as well as residential buildings.
or vertical suspended PVCu pipework. to cast iron.
Pipes and fittings are also suitable for use as internal and external rainwater pipes to drain flat
roofs and metal gutter systems on commercial and industrial buildings.

Waste ranges *

Compression
Solvent waste Push-fit waste Overflow Traps
waste
PVCu ABS Polypropylene PVCu Polypropylene Polypropylene

S uitable for Lightweight and F or internal use,  complete


A  ulti-fit
M  range of traps,
A
internal and cost effective ideally suited to range of compression which enable
external for internal fast installation. pipework socket, for quick & easy
applications. installation. Cost effective and fittings internal use. installation to Key fitting: Akavent Aerator
Easy to cut solution where for overflow Easy installation any new or
joint and install. systems are and boiler to similar sized existing plastic The need for secondary venting in high-rise buildings can be eliminated with the Akavent aerator. An Akavent
being installed condensate new or existing or copper aerator fitting breaks the discharge fall on each floor and as a consequence the secondary vent pipe is not
or modified. applications. plastic and pipework. required as the pressure difference stays well within the limit of 3 mbar.
copper pipework.
The unique shape of the fitting increases the capacity of the stack allowing the soil and waste flow from the
Available in Available in Available in Available in Available in Available in
higher floors to smoothly converge with the flow on the lower floor.
32, 40 and 50 mm 32, 40 and 50 mm 32, 40 mm 21.5 mm 32, 40 mm 32, 40 and 50 mm
White & Black White, Black White, Black White White & Chrome White & Chrome
& Grey & Grey

* For information on Multikwik compression waste and traps visit marleypd.co.uk.


ABS and polypropylene waste pipes and fittings are designed for internal use and should not be fitted externally
as they will be subject to ultraviolet light degradation. If fitted externally it is recommended that they are protected
Acoustic soil
by the application of a suitable paint or are boxed in.
An acoustic soil and waste range with a layered
KXT21
KAP2
WHB pipe providing quick, hygienic removal of
Technical advisory service
2No KR210 B032R
sanitary waste water. The noise generated
WHB
B032R KT2
by the flow of water is dramatically reduced
Marley Plumbing & Drainage provide technical support KAP2
S421150
SVD4
WC
– making it perfect for multi-occupancy
40
mm S411195
to all those involved with the specification and S201156
S411195
SBS40
MKS2 apartment blocks and high specification
installation of their products. This enables a specialist
GW059
KBA22
0m
m developments.
KB22 11

team to give detailed advice on the best way of


S241103
utilising the extensive range of products and systems WC
SBS40
0m
m
4No S411195
MKS2 11
manufactured by the company for building services.
UFC1

Technical Hotline: 01622 852695 2No S121145


3No S411195

4 | MARLEY PVC Soil & Waste MARLEY PVC Soil & Waste | 5
B
C
A
A

A
A
A

Solvent waste – PVCu B

C
B
A
C

B
B
A
A B
D

A
B
C B A C

PIPE BENDS
B B
Size mm Code Length Colour Qty Size mm Code Angle A B C D Colour Qty
B
32 KP104 4m WB 10 40 KBK25 90° 48 48 23 23 WB 20
C
A 40 KP204 4m WB 10 50 KBK35 90° 59 50 20 28 W 10
A A
50 KP304 4m WB 5 Knuckle bend/boss adaptor KBK35 is a Radius Bend which can solvent weld over
A B
Double spigot a boss upstand
A
C B B
B
Size mm Code Angle A B Colour Qty
STRAIGHT COUPLINGS
32 KBS1 87½° 92 18 W 20
Size mm Code A B Colour Qty
A 40 KBS2 87½° 92 23 W 20
B
32 KSC1 46 20 WB 60 A
A Solvent socket/spigot
40 KSC2 53 24 WB 30 B
50 KSC3 66 28 WB 30 TEES B
B Size mm Code Angle A B Colour Qty
A
A 32 KT1 88½° 92 57 WB 30
B 40 KT2 88½° 106 62 WB 20
B B A 50 KT3 88½° 135 78 A WB 10
C B Size mm Code A B C Colour Qty
A Solvent sockets
32 KEC1 86 61 20 W 10 D
B
C
A 40 KEC2 90 64 23 W 10
B
50 KEC3 82 50 30 W 10 Size mm Code Angle A B Colour Qty
A
A Expansion/adaptor
A 40 KT21 45° 117 78 W 20
B
A
A B 50 KT31 45° 149 100 W 10
B
PIPE CLIPS C
Solvent sockets
A
Size mm Code A B Colour Qty A
B CROSS TEE
C B 32 KF1 57 30 WBG 100 Size mm Code Angle A B Colour Qty
B B
40 KF2 62 30 WBG 100 B
A
40 KXT21 88½° 106 62 W 10
50 KF3 77 41 WBG 80 C
A A
50 KXT31 88½° 140 87 W 10
A
Open PVCu B
B Solvent sockets
A Size mm Code A B Colour Qty C
E A
B A
32 WC3 76 30 WB 100
C B A ACCESS PLUG D
40 WC4 82 30 WB 100 C
B Size mm Code A B C Colour Qty
50 WC5 100 38 W 80
A C 32 KAP1 22 53 8 WB 10
B Saddle A A 40 KAP2 25 57 8 WB 10
B
B B
BENDS 50 KAP3 33 71 8 WB 10
A
SOCKET REDUCER
Size mm Code Angle A B Colour Qty B
B Size mm Code A B Colour Qty
A B
32 KB1 88½° 57 18 WB 50 C A 32-21.5 KR175 22 20 W 100
40 KB2 88½° 62 21 WB 30 A
40-32 KR210 28 22 WB 80
A 50 KB3 88½° 78 28 WB 10
B 50-32 KR310 32 28 W 40
Solvent sockets C A BB 50-40 KR320 32 28 WB 40
A
B Solvent spigot/socket
IRON ADAPTORS
A
B
Size mm Code Angle A B Colour Qty Female
AA
B C B Size mm Code A B C Colour Qty
32 KB12 45° 29 18 WB 10 B
A 40 KB22 45° 33 21 WB 20 32 KFA1 50 25 20 W 10
50 KB32 45° 42 28 WB 20 40 KFA2 53 25 24 W 10
C B
A Solvent sockets A 50 KFA3 60 25 28 W 10
A
Solvent socket/BSP thread
B A
B
Male
A
Size mm Code Angle A B Colour Qty B CC B Size mm Code A B C Colour Qty
A B 32 KBA12 45° 24 23 W 40 32 KMA1 44 20 20 W 50
40 KBA22 45° 35 26 W 20 40 KMA2 47 20 24 W 40
A
Solvent socket/spigot A A 50 KMA3 53 20 28 W 40
B C
B C B Solvent socket/BSP thread

PVCc Solvent weld pipe is manufactured to BS EN 1566 PVCc Solvent weld pipe is manufactured to BS EN 1566 CAD drawing available to download from marleypd.co.uk
6 | MARLEY PVC Soil & Waste B C MARLEY PVC Soil & Waste | 7
PVCu Solvent weld fittings are manufactured to BS 5255 PVCu Solvent weld fittings are manufactured to BS 5255 A
A A A
B
C

Solvent waste – ABS B


A
B
B

B
A
A
A

A
B
B

A
PIPE A
ACCESS PLUG
Size mm Code Length Colour Qty Size mm Code A B C Colour Qty
C B
B
32 WAP33 3m WBG 10 32 WAA3 22 53 8 WBG 10
B
40 WAP43 3m WBG 10 40 WAA4 25 57 8 WBG 10
C B
C B 50 WAP53 3m WBG 5 50 WAA5 33 71 8 WBG 10
B A
AA
B
C
A
TEES A
STRAIGHT COUPLINGS A A
B Size mm Code Angle A B Colour Qty
Size mm Code A B Colour Qty
B
B 32 WAT3 88½° 90 55 WBG 30
C B 32 WAC3 40 20 WBG 40
A 40 WAT4 88½° 107 64 WBG 20
40 WAC4 46 23 WBG 30
B 50 WAT5 88½° 140 86 WBG 10
50 WAC5 63 30 WBG 30
A B
A

A
BB A
B
C B Size mm Code A B C Colour Qty

A 32 WAC31 86 61 20 W 10 A Size mm Code Angle A B Colour Qty


B 40 WAC41 90 64 23 W 10 B 32 WAT31 45° 102 65 W 20
A
50 KEC3* 82 50 30 W 10 C A 40 WAT41 45° 117 79 W 20
A
A A 50 WAT51 45° 150 100 W 10
Expansion/copper adaptor A
B
B
PIPE CLIPS C
Size mm Code A B Colour Qty A
C B C B
B
32 KF1 57 30 WBG 100 CROSS TEE B
40 KF2 62 30 WBG 100 CA
C B Size mm Code Angle A B Colour Qty
A
50 KF3 77 41 WBG 80 B
A 40 WAT42 88½° 106 65 W 10
A B
A Open PVCu B 50 WAT52 88½° 140 88 W 10
C A
BB A
Size mm Code A B Colour Qty A

A
B 32 WC3 76 30 WBG 100 B
A
40 WC4 82 30 WBG 100 A
A 50 WC5 100 38 W 80 SOCKET REDUCER
B B C
Saddle Size mm Code A B Colour Qty
B
A
40-32 WAR43 26 20 WBG 80
BENDS B C
50-32 WAR53 31 20 WBG 40
B Size mm Code Angle A B Colour Qty
B A 50-40 WAR54 31 23 WBG 40
32 WAB3 88½° 55 20 WBG 50 A
CA B
BA B
40 WAB4 88½° 64 23 WBG 30 IRON ADAPTORS
B A
B
50 WAB5 88½° 86 30 WBG 20 C
A Female
A C B
B Size mm Code A B C Colour Qty
A A
A
Size mm Code Angle A B Colour Qty
32 WAF3 50 25 25 W 10
A A 40 WAF4 53 25 24 W 10
B B 32 WAB31 45° 32 20 WBG 40 C B
A 50 WAF5 60 25 28 W 10
40 WAB41 45° 36 23 WBG 20 B
B 50 WAB51 45° 47 30 WBG 20
A
Male
A B
B C
Size mm Code A B C Colour Qty
AB

Size mm Code Angle A B Colour Qty A 32 WAM3 44 20 20 W 50


B A A
32 WAB32 45° 45 20 W 30 40 WAM4 47 20 24 W 40
B B C
40 WAB42 45° 48 23 W 20 50 WAM5 53 20 28 W 40
B AA
Spigot
A
B C
A
A CAP AND LINING A
B
Size mm Code A Colour Qty
B Size mm Code Angle A B Colour Qty
B 32 WAM31 58 W 10
32 WAB33 90° 44 20 WBG 30 A
C B
40 WAB43 90° 53 23 WBG 20 A
B A
A A
Knuckle bend B

A
A
A A
8 | MARLEY PVC Soil & Waste ABS Solvent weld system is manufactured to BS EN 1455-1 *PVCu ABS Solvent weld system is manufactured to BS EN 1455-1 CAD drawing
B
available to download from marleypd.co.uk MARLEY PVC Soil & Waste | 9
B
A
A

Push-fit waste – PP
B

B
B

A A

B
C B

PIPE TEE A
Size mm Code Length Colour Qty Size mm Code Angle A B Colour Qty

A 32 WPP33 3m WBG 10 32 WPT31 88½° 105 63 WBG 10


C B B
40 WPP43 3m WBG 10 40 WPT41 88½° 115 68 WBG 30
Ring seal sockets

A A

STRAIGHT COUPLING
Size mm Code A B Colour Qty
ACCESS PLUG
B Size mm Code A Colour Qty
32 WPC3 66 38 WBG 10
B A
40 WPC4 69 38 WBG 20 32 WPA31 20 WBG 100
B
40 WPA41 20 WBG 100
A Push-fit spigot
A

PIPE CLIPS
A
Size mm Code A B Colour Qty SOCKET REDUCER
A
BB B
32 KF1 57 30 WBG 100 Size mm Code A B Colour Qty
B
40 KF2 62 30 WBG 100 40-32 WPR43 45 36 WBG 10
A
Open PVCu Socket/spigot
A A

A
B C

B Size mm Code A B Colour Qty


B B
A
32 WC3 76 30 WBG 100
C B MULTI-FIT COMPONENTS
40 WC4 82 30 WBG 100 A
Size mm Code A B C Required Colour Qty
B hole size
A A Saddle BA C
32 WUM33 86 56 24 42 G 10
BENDS 40 WUM43 86 58 24 50 G 20
A A
B Fit BS EN 1451, BS EN 1455 or BS EN 1566 pipe. Straight tank connector
B A
B Size mm Code Angle A B Colour Qty
B
32 WPB31 45° 42 42 WBG 20
A
40 WPB41 45° 43 43 WBG 20
A

A
Push-fit sockets
MULTI-FIT WASTE CONNECTOR
B
B
Size mm Code A B Colour Qty
B
32 WCC3 75 25 W 200
Size mm Code Angle A B Colour Qty
B 40 WCC4 75 25 W 150
A
32 WPB32 45° 36 31 WBG 10
A Straight coupling
A 40 WPB42 45° 36 32 WBG 20
B B B
A Spigot/push-fit sockets

B B A
Size mm Code Angle A B Colour Qty A

32 WPB33 90° 60 60 WBG 10


A A 40 WPB43 90° 65 65 WBG 20
Knuckle bend

B
B
Size mm Code Angle A B Colour Qty

A 32 WPB34 88½° 75 37 WBG 10


A 40 WPB44 88½° 75 37 WBG 30
A
B Spigot/socket

marleypd.co.uk

Push-fit PP system is manufactured to BS EN 1451. PP cannot be solvent welded.


10 | MARLEY PVC Soil & Waste Push-fit PP system is manufactured to BS EN 1451. PP cannot be solvent welded CAD drawing available to download from marleypd.co.uk MARLEY PVC Soil & Waste | 11
A
B
B

Condense and Overflow system – PVCu A


B AC

A
B
B

B C
A
A

A
B

B A
B
A B C
PIPE
Size mm B Code
C Length Colour Qty
A
A A
21.5 OP21 4m W 30

Marley co-ex soil


B
B A
B
A
A
A
A
STRAIGHT COUPLING
B
Size mm Code
A
B
A B Colour Qty 110mm soil pipe with at least 30% recycled content
B
21.5 OSC21 28 13 W 10
B A
B
A

PIPE CLIP
A
A
A
A
Marley 110mm soil pipe now combines the environmental
A

B
B
C
Size mm

21.5
Code
A
OC21
A
A

44 14
B Colour

W
Qty

10
benefits of using recycled material with the quality and
A
A
A
Saddle
aesthetic advantages of co-extrusion technology.
A
BENDS B
Size mm Code
A
Angle A Colour Qty
• BS EN 1329 certified
AA
B
B
BA 21.5 OB90 90° 25 W 10
C
A C A
• Higher gloss levels
A
B
A
AB

Size mm AA
Code Angle A Colour Qty
• Improved weathering performance
B C
21.5 OB45 45° 13 W 10
A
A A
B • Available in grey and black
C
A

TEE • Same list price as standard white pipe


Size mm Code
A Angle A B C Colour Qty
B B
A
B
A
21.5 OT90
AA
90° 50 25 21.5 W 10 • Colour matched to all standard 110mm Marley soil fittings
AB C C
A A B
A
C
B B
B A
A A
ADAPTORS B A
A
A Female iron
B AC B
A C
SizeC mm Code A B C Colour Qty

A
21.5 OFA21 47 23 19 W 70 Accessories
A
B
B A
B
A Straight, to 22mm DURGO AIR ADMITTANCE VALVES B
A B A
A
Size mm Code B A B Colour Qty
C
A
A A C
21.5 OCA21B 39 13 W 150 A Size mm Code A B C Colour Qty
C C
B A 50 SVD2* 98 82 28 W 32
B
B
A Cap and lining 82 SVD3* 108 118 40 G 18
A B B
A Size mm Code A Colour Qty 110 SVD4 124 138 50 G 18
A
21.5 OCL21 46 W 100 C
Durgo valve including polystyrene insulating hood. *Can be fitted below flood level.
A C
A It is recommended this is fitted in a push-fit socket. BBA certified for use up to 10 storeys.
A

TANK CONNECTORS
B A B
Straight

A
A
B
Size mm Code A Colour Qty VENT TERMINAL
A A C 21.5 OTC21 50 W 10 Size mm Code A B Colour Qty

A A C 50 RV225 55 18 WBG 30
A Bent
A
Size mm Code Angle A B C Colour Qty A
B A
B B
A 21.5 OBC90 90° 48 25 13 W 10
C

A Including polyethylene washers and quick fix Acme threads

A
B
12 | MARLEY PVC Soil & Waste
A
CAD drawing available to download from marleypd.co.uk MARLEY PVC Soil & Waste | 13
AA
A
B

Push-fit soil – PVCu

A
A
B
C

B
C

D
PIPE ADJUSTABLE BENDS
Size mm Code Length A B Colour Qty Size mm Code Angle A B C Colour Qty

A
A

82 SP303 3m 100 76 BG 156 82 SB37 11-87½° 195 187 49 BG 10


B 82 SP304 4m 100 76 G 156 Push-fit socket/spigot

110MM CO-EX SOIL


C B Size mm Code Angle A B C Colour Qty

B
C
A 110 SP4025 2.5m 128 70 BG 100 D
110 SB46 5-14° 125 135 82 G 4
110 SP403 3m 128 70 WBG 2
110 SP404 4m 128 70 G 100 Push-fit socket/spigot

D
160 SP603 3m 182 107 G 46
Size mm Code Angle A B C D Colour Qty
160 SP604 4m 182 107 G 46
A

Push-fit socket 110 SB47 21-90° 189 187 90 127 BG 4


B Push-fit socket/spigot
STRAIGHT COUPLINGS C

C
Loose pipe socket A

B C C B
Size mm Code A B C Colour Qty
D Size mm Code Angle A B C D Colour Qty
82 SE300 103 50 48 BG 30 A
B
110 SE400 109 61 48 WBG 8 160 SB67 31-90° 285 275 96 184 G 2
B
160 SE600 190 107 77 G 4 Push-fit socket/spigot
C

A
A
OFFSET BENDS
A
C
Size mm Code Angle A B C Colour Qty
B Double ring seal slip coupling C
C
A
A 110 SNE405 67½° 94 91 60 WBG 4
Size mm Code A B Colour Qty
D C
B Push-fit solvent socket
82 SE305 104 49 BG 30 A

110 SE405 128 64 BG 8 B

160 SE605 170 83 G 4 B

B
A
B Size mm Code Angle A B C Colour Qty
B C
C C
82 SNE300 67½° 98 86 57 BG 30
A
B Triple socket 160 SNE600 67½° 178 182 88 G 140
A
Size mm Code A B Colour Qty B Push-fit solvent socket.
110 SE402 311 82 G 4
A C
A
A B

A
EQUAL BRANCHES
B
A
Size mm Code Angle A B C D Colour Qty
SHORT RADIUS BENDS
B 110 SY401 87½° 299 150 60 175 W B G 4
Size mm Code Angle A B C Colour Qty
A 160 SY601 87½° 438 245 96 260 G 2
82 SB31 87½° 138 115 49 BG 20
110 SB41 87½° 158 157 70 WBG 4
B B
C
160 SFB61 87½° 242 232 88 G 1 A

D
Push-fit socket/spigot C
C
B
C A Size mm Code Angle A B C Colour Qty

B
82 SB35 45° 76 73 49 BG 20
Size mm Code Angle A B C Colour Qty
110 SB45 45° 84 89 62 WBG 4
A
82 SY36 45° 229 130 55 G 10
160 SFB65 45° 120 118 85 G 2
A 110 SY460 45° 285 198 62 BG 4
Push-fit socket/spigot A
C 160 SY63 45° 400 200 90 G 2
Size mm Code Angle A B C Colour Qty B
Push-fit sockets/spigot
A
110 SB411 88½° 135 145 50 BG 4 B

Double push-fit socket


B
C 76 A

D
A C C
B
C

14 | MARLEY PVC Soil & Waste B To BS 4514 and / or BS EN 1329 'B' as appropriate CAD drawing available to download from marleypd.co.uk MARLEY PVC Soil & Waste | 15
A
C
C
B

A A A

Push-fit soil – PVCu


C
A
A B
C
B

B B

EQUAL BRANCHES CORNER BRANCH


C C
Size mm Code Angle A B C Colour Qty C B Size mm Code Angle A B C D Colour Qty

A 110 SY466 45° 282 198 62 BG 4 110 SY411£ 87½° 287 143 60 175 G 4
C
A
A D Push-fit sockets/solvent socket A Push-fit sockets/spigot. 1 boss upstand
C D
A
A B
C

B
B
BOSS PIPES C
Size mm Code Angle A B C Colour Qty
FIVE BOSS BRANCHES
B F
B
110 SW41 87½° 204 86 82 WBG 4
Size mm Code Angle A B C D Colour Qty C
B E A Push-fit socket/spigot. 1x40mm boss connection
B

D
110 SY405 87½° 287 143 60 175 WBG 4 A
C

C
C
Push-fit sockets/spigot A A
E B A
C A
B
76 A C Size mm Code Angle A B C Colour Qty
B
C
D
C
110 SW415 87½° 204 86 82 BG 4
A
D
Push-fit socket/spigot. 1x32mm boss connection
B

B
A
Size mm Code Angle A B C D Colour Qty
A

SYS415 110 SYS415 87½° 280 143 60 168 BG 4 BOSS PIPES C


B

Size mm Code Angle A B C Colour Qty


A Push-fit sockets/solvent socket
76 A
82 SW30 90° 202 101 49 BG 15
D
C B C
Push-fit socket/spigot. 3 boss upstands, 1 drilled
C

THREE BOSS BRANCH


Size mm Code Angle A B C D Colour Qty A
B C

82 SY33F 87½° 212 122 52 121 B G 10 B Size mm Code Angle A B C Colour Qty
A
B

B
B
110 SW40 90° 244 123 70 WBG 4
A
A Push-fit socket/spigot. 4 boss upstands
SYS405 65
D
B
C A

UNEQUAL BRANCHES 76
A
C
D Size mm Code Angle A B C Colour Qty ACCESS PIPES C

C
B
160x110 SY64 87½° 337 175 175 G 2 A Size mm Code A B C Colour Qty
CC
Push-fit sockets/spigot. 2 boss/access upstands A
B
82 SF31 205 101 52 BG 15
A
A
A B

B B
C
B

C D
UNEQUAL BRANCHES Size mm Code A B C D Colour Qty
C
Size mm Code Angle A B Colour Qty 110 SF41 244 123 70 152 B G 4
A B

B 160x110 SY66 45° 335 306 G 2 A Socket/spigot


Push-fit sockets/spigot B
C
A

A
REAR ACCESS BENDS
D Size mm Code Angle A B C Colour Qty

DOUBLE BRANCH 110 SB42 87½° 138 146 55 BG 4


C A

Size mm Code Angle A B C D Colour Qty A B Push-fit socket/spigot


B
110 SY404 87½° 288 141 54 76 G 4
C
Push-fit sockets/spigot. 2 boss/access upstands
B
B
Size mm Code A B C Colour Qty
C
A
C D
82 SB38 124 127 57 BG 1
Push-fit socket/spigot
A
D

16 | MARLEY PVC Soil & Waste To BS 4514 and / or BS EN 1329 'B' as appropriate CAD drawing available to download from marleypd.co.uk MARLEY PVC Soil & Waste | 17

B
B A
A

Push-fit soil – PVCu Solvent soil – PVCu


C

B
A

REAR ACCESS BRANCHES PIPE


B A
Size mm Code Angle A B C D Colour Qty 110MM CO-EX SOIL
110 SY402 87½° 287 143 60 175 B G 4 Size mm Code Length Colour Qty
4 boss upstands 110 SL403 3m WBG 100
C
110 SL404 4m G 100
76 A
160 SL603 3m G 46
D 160 SL604 4m G 46
C
Double spigot

REAR ACCESS BRANCHES STRAIGHT COUPLINGS


B C
Size mm Code Angle A B C D Colour Qty B C Loose pipe socket
B
82 SY34F 87½° 212 121 52 101 B G 6 Size mm Code A B C Colour Qty

B A 82 SE300 103 50 48 BG 30
C
110 SE400 109 61 48 WBG 8
76 A
160 SE600 190 107 77 G 4
A
A A
D
C A
B
B Double solvent socket
C
A Size mm Code A B C Colour Qty
BOSS CONNECTOR C
B B 82 SES301 93 44 82 G 50
Size mm Code Angle A B Colour Qty
B 110 SES401 102 50 124 BG 8
B
32 SA411 87½° 43 21 WBG 50 C A
160 SES601 174 64 128 G 4
40 SA421 87½° 43 21 WBG 40
B
C
A 50 SA420 87½° 66 45 BG 40 EXPANSION COUPLING B
A
A Solvent weld with push-fit seal B
LEVEL INVERT REDUCERS C Solvent socket ring seal adaptor
Size mm Code A B C Colour Qty Size mm Code A B C Colour Qty
A

A
B B 110x82 SRM304 192 78 82 BG 20 110 SE409 105 20 52 BG 8
A B
B A
Spigot/socket C A To accommodate thermal movement in both vertical and horizontal solvent pipework
A

B
B
A

A
B

Size mm Code A B C Colour Qty SHORT RADIUS BENDS B


A
C Size mm Code Angle A B C Colour Qty
160x110 SRM604 219 90 82 G 4
A C
Spigot/socket A 110 SBS41 87½° 162 168 50 G 4
B

A
C
C

Solvent socket/spigot
CONCENTRIC REDUCER
A
Size mm Code A B Colour Qty
B Size mm Code Angle A B C D Colour Qty
110-50 SE41 105 135 BG 18
B
A C
B 110 SBS42 87½° 149 149 47 119 B G 4
Spigot to boss upstand
160 SBS62 87½° 186 186 66 G 2
A
B
C Double solvent socket
Size mm Code A B C Colour Qty

160 SRS604 168 68 20 G 6 B C

Spigot/socket
C A
A B A
C
C A Size mm Code Angle A B C Colour Qty
B A
110 SBS45 45° 76 76 52 BG 4
B
C
A 160 SBS65 45° 98 98 66 G 2
B B
C Double solvent socket
ADAPTOR
C Size mm Code A B C Colour Qty
C B A
C 110 SA42 130 65 130 B 40
B A
B
Soil to drain adaptor A
A A A

Size mm Code Angle A B C Colour Qty

C B 110 SBS415 45° 76 89 52 BG 4


C
B Size mm Code A B C Colour Qty 160 SB615 67½° 168 175 76 G 2
B
C B

B
B 110 SA110 58 25 34 B 10 Solvent socket/spigot
C B
A B
A Waste to drain adaptor D
A
B
A C D
A
C A
18 | MARLEY PVC Soil & Waste To BS 4514 and / or BS EN 1329 'B' as appropriate CAD drawing available to download from marleypd.co.uk MARLEY PVC Soil & Waste | 19
110mm 500mm
Solvent soil – PVCu B

SYS415
A
76

D
C

LONG RADIUS BEND EQUAL BRANCH

A
Size mm Code Angle A B C D Colour Qty Size mm Code Angle A B C D Colour Qty

A
B
B
B

110 SBS40 87½° 114 240 48 110 W B G 4 SYS405 110 SYS405 87½° 272 135 55 168 B G 4
Solvent socket/spigot Triple solvent socket. 5 Boss upstands

B
D

B
A
C A
76
A
D
B
C C

C
A

C
D
C

C
B
Size mm Code Angle A B C D Colour Qty
OFFSET BENDS
160 SYS601 87½° 270 180 66 205 G 2
Size mm Code Angle A B C Colour Qty
C Triple solvent socket
A 110 SNE405 67½° 76 61 60 WBG 4 A

Push-fit solvent socket D


C

B
B
B Size mm Code Angle A B C D Colour Qty

Size mm Code Angle A B C Colour Qty 110 SY415 87½° 279 135 55 175 B G 4
SYS415 A
C 82 SNE300 67½° 88 48 49 BG 30 Solvent socket/spigot. 5 Boss upstands
A D
160 SNE600 67½° 178 182 96 G 140 76
A

Push-fit solvent socket. C


D
C

B UNEQUAL BRANCHES

EQUAL BRANCHES Size mm Code Angle A B C Colour Qty

Size mm Code Angle A B C Colour Qty 160 SYS644 45° 286 169 55 G 4
110 SYS460 45° 277 135 55 BG 4 A
C
Solvent sockets/spigot
B
A
C

B
B
Size mm Code Angle A B C D Colour Qty

160 SYS664 87½° 234 132 52 118 G 4


A

D
Size mm Code Angle A B C Colour Qty
A
110 SY466 45° 282 138 60 BG 4 C
C
Push-fit sockets/solvent socket DOUBLE BRANCH
B
Size mm Code Angle A B C D Colour Qty
B
110 SYS404 87½° 274 133 45 76 G 4
C
All solvent sockets, 4 boss upstands

Size mm Code Angle A B C Colour Qty A


D

A
110 SYS466 45° 274 135 55 BG 4
C
160 SYS666 45° 362 194 66 G 4
Triple solvent socket
B CORNER BRANCH
Size mm Code Angle A B C Colour Qty
B
110 SYS411 £
87½° 272 135 55 G 1
C
All solvent sockets. 1 boss upstand

20 | MARLEY PVC Soil & Waste To BS 4514 and / or BS EN 1329 'B' as appropriate CAD drawing available to download from marleypd.co.uk MARLEY PVC Soil & Waste | 21
B
A
B

Solvent soil – PVCu A


C

C
A
F
B C
A
BOSS PIPES B 8-WAY COLLAR BOSS
C
Size mm Code Angle A B C Colour Qty Size mm Code A B C D E F G H Colour Qty
F

110 SWS4135 45° 186 93 145 G 4 E


C
A 110 SCBL41 184 146 140 164 61 204 532 70 G 1
B

Push-fit socket/spigot. 1x40mm boss connection H


Solvent socket/spigot with 350mm spigot tail
A
B E A
B
Size mm Code Angle A B C Colour Qty
G

C 110x32 SWS415 87½° 170 85 52 WBG 4


F
C A Push-fit socket/spigot. 1x32mm boss connection
C
C B FG
G

C
A Size mm Code Angle A B C Colour Qty
D
B
A 110x40 SWS41 87½° 170 85 52 WBG 4 BOSS PIPES E A
B
B Push-fit socket/spigot. 1 drilled boss upstand Size mm Code Angle A B C Colour Qty

B A D
C 110 SWS40 90° 179 92 55 BG 4
E A
B 160 SWS60 90° 200 100 66 G 4
A
Size mm Code Angle A B C Colour Qty D
B Double solvent socket. 4 boss upstands, 1 drilled
110x50 SWS42 87½° 170 85 52 BG 4
Push-fit socket/spigot. 1 drilled boss upstand
D
C Size mm Code Angle A B C D Colour Qty
STRAP-ON-BOSS 110 SWS405 90° 179 92 54 BG 4
A
Required A
Size mm Code Angle A B Colour Qty Solvent socket/spigot. 4 boss upstands, 1 drilled
B A hole size
B
B A 32x110 SWS4150 90° 70 55 50 BG 40 B C
F
40x110 SWS410 90° 70 62 50 BG 40 C
50x110 SWS420 90° 86 75 63 BG 30
A A
D Size mm Code Angle A B C D Colour Qty

110 SWS406 90° 184 55 87 60 G 4


CONDENSATE STRAP-ON-BOSS A C
B B Push-fit/Solvent socket. 4 boss upstands.
Size mm Code Angle A B Colour Qty E A
C B
21.5x110 SWS4C 90° 70 21.5 G 50 B
B A
A
Size mm Code Angle A B C Colour Qty

160 SW60 90° 335 110 96 G 4


B C
PATCH BOSS
D
Solvent socket/spigot.
Size mm Code A B Colour Qty A B

32x82 SWS332 95 18 G 20
A 40x82 SWS340 95 23 G 20
A 50x82 SWS350 95 27 G 20 CONDENSATION TRAP A

A Size mm Code A B C Colour Qty


B A
B 110 SCT4 115 82 22 G 6
B
B
8-WAY COLLAR BOSS
B C
With 21.5/22mm overflow connection
Size mm Code A B C D E F G Colour Qty
F
C
110 SCB41 195 157 140 195 61 204 70 G 1
G Solvent socket/spigot ACCESS CAPS
D
Size mm Code A B Colour Qty
E A
B
C A
82 SE30 114 35 BG 30
110 SE40 150 37 BG 30
D
A
160 SE62 195 40 G 15
A
B
B

F B
C ACCESS PIPES
Size mm Code A B C D E F G Colour Qty Size mm Code A B C D Colour Qty
G D
110 SCBS41 184 146 140 164 61 204 70 G 1 110 SFS41 150 75 56 154 W B G 4
E A D
B Double solvent socket tail C A Double solvent sockets. 3 boss upstands
B
D C
A

B
A
22 | MARLEY PVC Soil & Waste To BS 4514 and / or BS EN 1329 'B' as appropriate CAD drawing available to download from marleypd.co.uk MARLEY PVC Soil & Waste | 23
B
C
C
B A
A
B

Solvent soil – PVCu Accessories C


C
B
B
A
A

B
B

B
B
A
A D
A D
A
C
C

ACCESS PIPES VENT TERMINALS 110mm


110mm 500mm
500mm
D Size mm Code A B C D Colour Qty Roof cowl/vent terminal
C
C
C
160 SF611 287 144 138 223 G 2 C
C B Size mm Code A B C Colour Qty
B
1 1
Double solvent sockets 110 SVC1 2 200 98 70 WBG 10
A
A 2
3
3
A 750mm
750mm
B
B A
Vent terminal
C
C Size mm Code A B C Colour Qty
REAR ACCESS BEND B
B
A
A 82 SV321 90 30 75 BG 30
Size mm Code Angle A B C Colour Qty
A 110 SV42 117 34 95 WBG 60
110 SBS420 87½° 131 128 54 BG 4
A
A C A B
Double solvent socket C A B

B
B
B Vent terminal
C B

Size mm Code A B C Colour Qty

160 SV62£ 160 71 25 G 20


A
BOSS CONNECTORS C
B B
A
B
Size mm Code A B Colour Qty A
B
CLIPS
32 SA415 35 20 G 50
Socket clip
A 40 SA425 30 25 BG 50
B Size mm Code A B Colour Qty
A
B 50 SA435 58 28 G 50 A

B
110 SC41 152 101 BG 50
Solvent weld with solvent weld joint A
B
160 SC61 240 121 G 50
A PVC coated mild steel, includes 6x20mm nut and bolt
A A
B C Size mm Code Angle A B C D Colour Qty
B
40 KBK25 90° 48 48 23 23 WB 20 Barrel clip collar
A

50 KBK35 90° 59 50 20 28 W 10 Size mm Code Colour Qty


B
D

Solvent weld 1000 SC621 G 25


B
A Converts socket clip to pipe clip (3x110mm or 2x160mm)
C
B B A
Size mm Code A B Colour Qty Pipe clip
A 32 SA411 43 21 WBG 50 B Size mm Code A B Colour Qty
C A
B 40 SA421 43 21 WBG 40 B 82 SC35 125 93 BG 20
A
50 SA420 66 45 BG 40 A
A
B
B 110 SC45 150 101 WBG 50
C
A B A
B
PVCu
CONCENTRIC REDUCERS A

A
B A
Size mm Code A B C Colour Qty
A Pipe clip
B B
A 110-50 SE41 105 135 BG 18 A Size mm Code A B Colour Qty
B
Spigot to boss upstand. Spigot/Socket 82 SC35S 117 70 BG 20
B B B
A D For use with drive-in spike or backplate.
A
A B C
Size mm Code A B C Colour Qty
A Extension backplate
110mm SRS604
160-110 168 68 20 G 6
C A B
A B A 500mm
C B Code A B Colour Qty
D Spigot/Socket C A
C
A C A
RT200 104 45 W B G BR 50
C
B B A PVCu
B 1 For use with RC251/2, RCE2 and RC32 pipe clips
B
2
ECCENTRIC REDUCERS A A 3
C
A 750mm
B
Size mm Code A B Colour Qty B
Drive-in spike
C
B A B Code A B C Colour Qty
82-50 SRM30 66 35 BG 90 A
B C
A C
Spigot tail A RSS1£ 115 58 19 G 50
B B C
A Galvanised mild steel
C A
B
B A B C
Size mm Code A B C Colour Qty A A Extension backplate
C A
BA A C Code A B Colour Qty
A 76
B C 110-50 SRM402
A B 48 25 19 BG 10 B A
C
C
BD Solvent socket to boss upstand
B
RCB300 48 31 W B G BR 100
B
B A
For use with SC35S
A D
A
C C To BS 4514 and/or BS EN 1329 'B' as appropriate To BS 4514 and/or BS EN 1329 'B' as appropriate. AccessoriesAB are suitable for both push-fit and solvent soil systems
24 | MARLEY PVC Soil & Waste B A CAD drawing available to download from marleypd.co.uk CAD drawing available to download from marleypd.co.uk MARLEY PVC Soil & Waste | 25
B
A C B
B
A

B
A

Product range
Accessories A WC connectors B

B A
B

A A B

A
CLIPS STRAIGHT CONNECTORS C

B B Size mm Code Angle A B C Colour Qty


B

C B
Extension Bracket
A 110 SG40 14° 63 50 134 W 4
B B A
Code A B Colour Qty Spigot
C

A A 110 RT250 243 114 BG 20 AC

A A
A=111 (HOLE-SAW SIZE)
B=35

A Cover plate B
B
C
C Size mm Code Angle A B C D Colour Qty
B A Code A B Colour Qty B A DB
B C 110 SGS41W* 14° 139 134 53 80 W 20
110 RT2501 111 35 BG 1 C
C
B 
B Solvent socket. Pan socket to be trimmed to suit WC spigot length
A For use with RT250 C
A B
A
B AA A

A=137
A C
B=111 B
A Pipe clip BENT CONNECTORS A
Code A B Colour Qty A
B Size mm Code Angle A B C Colour Qty
C A B A
A D
B A
B 110 RPC1 137 111 A BG 20 A 110 ST40 90° 106 125 51 W 4
B
C B
Solvent socket
B
A=141 B
B=119
Socket clip B C
A 110mm 500mm A C
Code A B Colour Qty CC
C C
A
C 110 RSC1 141 119 BG 1 B
B B A D
B A
C A
B
A
1 C
A 2
C D B
Size mm Code Angle A B C Colour Qty
DURGO AIR ADMITTANCE VALVES 3
750mm A
110 ST41W 90° 106 240 210 W 4
B Size mm Code A B C Colour Qty
B Long spigot
B A
50 SVD2* 98 82 28 W 32 B
B
BSVD3* C
A 82 D 108 118 40 G 18 B D
C A B A
C
A
B 110 SVD4 124 138 50 G 18
D
A
 C Durgo valve including polystyrene insulating hood. *Can be fitted below flood level. B B
A C
C
It is recommended this is fitted in a push-fit socket C
110mm 500mm B C
Weathering
110mm collar
A
C 500mm
A Size mm Code AB B C Colour Qty Size mm Code Angle A B C D Colour Qty
C A C
C C
C B B 82 SV31* 51 94 25 B 100 D
D 110 STS41W* 85° 104 156 53 80 W 4
C
1 110 SV43 57 130 25 WBG 35 
A D Solvent socket. Pan socket to be trimmed to suit WC spigot length
C B
A 2 B B C
3 B
750mm 1 in black rubber only.
PVCu for solvent joint to pipe *Available
2 B
A D
3
WEATHERING SLATES 750mm A
A

Size mm Code A B Colour Qty A A


C
A C
B 400 SAS40 400 400 G 5 B
A
D B
C Flat. Manufactured from aluminium and rubber B
Size mm Code Angle A B C D Colour Qty
B
B A
Size mm Code A B Colour Qty 110 SBS40W 90° 114 240 48 110 W 4
A
A
C A B
450 SAS45 450 450 G 5 Long spigot/ solvent socket
B
B
B 610 SAS61 610 610 G 5 A
C
A
C
A Inclined. Manufactured from aluminium and rubber A A
C
C A B
C
B D
D

WC SEAL AND CAP D D

83 – 114mm outlet
B
B Size mm Code A B Colour Qty
B
A
SA323W 141 24 70
A
A
For use with SGS41 and STS41
A

C B
To BS 4514 and/or BS EN 1329 'B' as appropriate. Accessories are suitable for both push-fit and solvent soil systems
26 | MARLEY PVC Soil & Waste CAD drawing available to download from marleypd.co.uk *When fitted to short WC pan spigots, pan Dsocket should be trimmed to suit before SA323W (not supplied) is fitted. MARLEY PVC Soil & Waste | 27
Universal push-fit WC connectors WC manifold system

A A
STRAIGHT CONNECTORS BRANCH
Size mm Code Angle A B C D Colour Qty Size mm Code A B C Colour Qty
B AA A
D
B
100 SWC11 132 110 81 46 W 25 C C 110x90 SM41W 214 50 116 W 10
D Solvent sockets
B C
B CB
A D C
B
A C
B
B
B

A C C

D ADJUSTABLE WC BEND
B A
D A A Size mm Code Angle A B C D Colour Qty
B
Size mm Code Angle A B C D Colour Qty
A 90 SM42W* 50-90° 108 134 75 60 W 15
A D AA
B 100 SWCB14 14° 132 61 81 46 W 20 A 50mm boss upstand
A C B B
Pan socket to be trimmed to suit WC spigot length
C B C C
A BB
C
C
C
D D
C
B D
D D
D
C
D

A
18
D ADJUSTABLE SPIGOT BEND
C
A A AA A Size mm Code Angle A B Colour Qty
18 A
C A
A
90 SM43W 50-90° 119 75 W 15
18 B Size mm Code Angle A B C D Colour Qty
C 50mm boss upstand
B 100 SWC22 22° 132 115 81 46 W 25
B B
B B
B
B
B

WC CONNECTOR
C
A Size mm Code A B C D Colour Qty
A
A A
LONG BENT CONNECTOR A
90 SM44W* 117 134 46 80 W 30
Size mm Code Angle A B C Colour Qty B
B 50mm boss upstand
D 100 SWCB90D B 90° 132 235 81 W 10 B B B C
Pan socket to be trimmed to suit WC spigot length
D
C

B
D
D* C C
D*
B D* C
A D C
A D* D* C C
E C
C
A
B

E
C
A
A
D

E B
A C EXTENSION PIPE B
B
B
Size mm Code A B Colour Qty
E

B
A

B B
B A
A B 90 SM45W 96 46 W 50
A 300mm
A A For use with SM43 only
EXTENSION PIECE
A

Size mm Code A B C D Colour Qty A


C
A

B 100 SWCE33 81 300 116 226 W 12


D
B
D
A

WC SEAL AND CAP


B

C
C A
B

83-114mm outlet
B Size mm Code A B Colour Qty
B

90 SA323W 141 24 W 70
A
C

A For use with SM42 and SM44


C
C
C
C
C

28 | MARLEY PVC Soil & Waste Push-fit WC connectors are manufactured to BS 5627. CAD drawing available to download from marleypd.co.uk *When fitted to short WC pan spigots, pan socket should be trimmed to suit before SA323W (not supplied) is fitted. MARLEY PVC Soil & Waste | 29
B
D
B
D
Product range

Fire protection Pipe support systems


PIPE WRAP CHANNEL STRIP
Size mm Code A B C Qty Size mm Code Colour Qty
C
110 SFW44 475 75 10 200 2000 JCS2 Strip NU 50
JCA1 Angle NU 10
A
BARREL CLIP COLLAR
B
Code Colour Qty
Pipe support- channel strip Channel angle
Pipe support-
FIRE COLLAR SC621 NU 25
Size mm Code No. of lugs A B Qty 1m PVC strip when cut to length. Converts pipe bracket to pipe size
A
(3x110mm or 2x160mm)
50 SFC50 3 74 60 1
NUTS AND BOLTS
B 82 SFC82 3 100 60 1
Size mm Code Colour Qty
110 SFC110 4 134 60 1
C 160 SFC160 6 200 60 1 20x6 RNB11 NU 1

For further details of Marley Plumbing & Drainage fire collars, please go to marleypd.co.uk. Ancillary items
Pipe support- Nut/bolt
PVCu floor outlets SOLVENT CEMENT
Tub
TRAPPED FLOOR GULLIES Size Code Qty
Size mm Code A B C D Colour Qty
250ml KS10 Tub 20
A
110
50 SFG42AS 117 164 145 116 G 8
Solvent outlet. 90mm adjustable water seal 500ml KS20 Tin 20
To BS EN 14680
B

D
SILICONE LUBRICANT
Size mm Code A B C D Colour Qty

82 SFG43AS 117 164 175 100 G 8 Tube with sponge applicator


Size Code Qty
C Solvent outlet. 75mm adjustable water seal
50g SZ50 10

STAINLESS STEEL TILE GRATE AND COVER


Code A B C Colour Qty
C Bottle
150x150 SGG4 150 150 7 NU 40
Size Code Qty
Grade 304 stainless steel
A B 100g SZ100 50

Aerosol*
Pipe support systems Size Code Qty

400ml SZ400 12
TWO PIECE PIPE BRACKET
Size mm Code Colour Qty

110 JB42 NU 50 Tub


160 JB62 NU 50
Size Code Qty

500g SZ500 24
Water Research Centre Approved

BASE PLATE SPARE RING SEALS


Soil & vent JB32 Size mm Code Colour Qty
‘T’ ring
110 JBP42 Double support NU 1 Size mm Code Qty
160 JBP62 Double support NU 50
82 SR82T 5
JDP1 Single support NU 50
110 SR110T 5
Double Single
160 SR160T 5
To BS EN 681/1

Pipe
30 support-
| MARLEY PVC SoilD/supp
Pipe
& Waste
support-
base plate single plate CAD drawing available to download from marleypd.co.uk MARLEY PVC Soil & Waste | 31
Design

Bends at the base of stacks


Sanitary pipework design Bends at the base of vertical stacks should be of long radius and have a
All sanitary pipework systems should be designed to satisfy the following regulations and standards where applicable. minimum centre line radius of 200mm on a 110mm nominal size stack.
Two 45° radius bends may also be used as an alternative to provide the
●● The Building Regulations 2010: Approved Document H, Section 1.
change of direction and connection to the building drain. The same
●● The Building Standards Technical Handbook (Scotland) 2010: Part M. design principle should also be adopted where offsets occur in stacks min 200mm
radius
of one or more storey height.
●● The Building Regulations (Northern Ireland) 2000, Technical Handbook N.
Where pipework is suspended in a ceiling void or car park, it is
●● BS EN 12056: 2000, Parts 1 to 5.
recommended that two 45° solvent weld bends are used with a short
Regular consultation is essential between Architects and Plumbing Engineers throughout the building design stage as the careful arrangement of piece of pipe between to ensure the radius exceeds that required.
kitchen and bathroom appliances will simplify the final sanitary pipework layout. This will help to ensure that an efficient sanitary pipework system
is installed at minimum cost. long radius bend
UBL488
The design information provided in this catalogue is endorsed in the above publications and while every effort has been made to ensure accuracy,
no responsibility can be accepted for errors or omissions. For detailed guidance please consult the relevant documents referred to above.

Methods of jointing
SWS415/41
82, 110 and 160mm PVCu pipes and fittings are available in both solvent and push-fit jointing boss pipe
methods. Solvent soil is widely used on smaller diameter waste and overflow pipework, although Branches at the base of stacks
expansion and copper adaptor couplings include a push-fit joint to allow for thermal movement. solvent
weld joint
For single dwellings up to three storeys high, the distance between the
As polypropylene cannot be solvent welded, the push-fit method of jointing is used throughout centre line of the lowest branch connection and the invert of the drain
the system. should be at least 450mm. For multi-storey systems up to five storeys
high, the minimum distance should be 740mm and for systems higher
push-fit than five floors no connections are permissible at ground floor level.
joint Where this occurs a separate stub stack should be provided to serve UBL488 or
Thermal movement the ground floor or individual appliances should have their own L
2 – UB455 bends
separate connection to the building drain.
The coefficient of linear expansion for PVCu is 0.06mm/m/°C. As a result a 3m length of
pipe will increase in length by approximately 3.6mm when subjected to a 20°C temperature
variation. Therefore, it is important to ensure that any movement is controlled and push-fit
joints are installed to accommodate any expansion that may occur due to increases in ambient
temperature or hot water discharges.
L = 450mm up to three storeys high
L = 740mm up to five storeys high
L = one storey height, over five storeys

Sizing of soil stacks Material and manufacture Dimensions and weights


It is recommended that the guidance given within BS EN 12056, part 2 be adopted when sizing soil Marley Plumbing & Drainage pipes and fittings for sanitary pipework Mean Outside
Pipe BS Nominal Wall
stacks. Marley Technical Services Department offer design and installation advice, including the sizing systems are manufactured from different plastics materials including Diameter (mm) Weight
Material Size Thickness
of soil stacks, for customers who use or specify Marley Plumbing & Drainage products. PVCu, PVCc, ABS and PP. kg/metre
Standard (mm/inch) Min Max (mm) Min

Soil stack capacity The table right details the important dimensions and weights of each Soil
of the systems together with the relevant British and European Standard. PVCu 82 82.4 82.8 3.20 1.30
The capacity of a soil stack can be increased by the installation of a secondary ventilated stack. The All pipes are manufactured using a continuous extrusion process and
following information is taken from tables 11 & 12 of BS EN 12056-2: 2000 which illustrates this increase. BS EN 1329 110 110.0 110.3 3.20 1.70
fittings are produced by high-pressure injection moulding.
BS 4514 160 160.0 160.4 3.20 2.50
Waste
Chemical and temperature resistance MUPVC 36/1¼ 36.15 36.45 1.80 0.33
Primary ventilated stack Secondary ventilated stack Most plastics used for sanitary pipework are highly resistant to those BS 5255 40/1½ 42.75 43.05 1.90 0.41
Stack size Maximum capacity (l/s) Stack size Secondary vent Maximum capacity (l/s) chemicals normally found in domestic waste water and sewerage systems. 50/2 55.75 56.05 2.00 0.57
For applications where chemical discharges are likely to occur, HDPE soil Waste
(mm) Swept entries (mm) (mm) Swept entries range may be more suitable. ABS 32/1¼ 36.15 36.45 1.80 0.20
82 2.6 82 50 3.4 Generally the maximum working temperature of Marley PVCu, dBlue BS 5255 42.75 43.05 1.90 0.26
43/1½
110 5.2 110 50 7.3 & HDPE soil and waste systems when subjected to continuous flow is BS EN 1455-1 50/2 55.75 56.05 2.00 0.35
160 12.4 160 80 18.3 70°C and 75°C respectively. Higher intermittent discharges of up to Waste
95°C may be accommodated by PVCu provided the period of discharge Polypropylene 32/1¼ 34.45 34.75 1.80 0.21
does not exceed one minute duration.
BS 5254 40/1½ 40.85 41.15 1.90 0.26
Alternatively, reference can be made to ISO publications TR10358 Overflow
& TR7620 which provide comprehensive information on chemical PVCu 21.5/¾ 21.55 21.70 1.10 0.11
Secondary ventilated stack and temperature resistance of plastics and rubber materials. BS 6700

32 | MARLEY PVC Soil & Waste All documentation is available to download from marleypd.co.uk Technical hotline: 01622 852695 MARLEY PVC Soil & Waste | 33
Design

Offsets in stacks Stub stacks 8-way collar boss Branch pipe gradients
Offsets in the wet portion of a discharge stack An unventilated stub stack terminated with an The gradient of a branch pipe should be
should be avoided wherever possible but access fitting may be used to connect a group uniform and adequate to drain the pipe and
where they have to be fitted a large radius or of ground floor appliances to the building drain appliance efficiently. A minimum gradient of
SY401 Equal Branch
two 45° bends should be used to create each provided the vertical drop to the invert level 18mm/metre should be adopted for 32, 40 and
change of direction. Offsets in lightly loaded of the drain does not exceed 1.5m from a WC 50mm nominal size pipes but larger diameter
stacks up to three storeys high do not require and 2.5m from a waste appliance. Where one 82, 110 and 160mm branch runs may be laid
Top & side waste
offset venting but on multi-storey buildings this or more stub stacks are connected to the same connections flatter at 9mm/metre fall where the discharge
may be necessary depending on the loading drain, the head of the run should be ventilated for maximum flow rate exceeds 2.5 litres/second.
of the stack and the numbers of floors above to atmosphere or air admittance valves fitted flexibility, even
in tight spaces.
the offset. The principles previously described to each stub stack arrangement. Design prevents Branch pipe lengths
for bends and branches at the base of a stack any danger of
should also be applied. SE40 cross-flow. The following information is taken from Table 8
access cap of BS EN 12056: 2: 2000 and provides general
SWS415/41 Hole cutter locator
guidance on the recommended lengths
Stub waste boss pipe
Factory fitted, air of unventilated branch pipes for a variety
This technique is often used to connect isolated tested joint ensuring 61mm of sanitary appliances.
long term integrity.
ground floor waste appliances such as basins,
No need for pipe to be cut
baths, shower trays and sinks to eliminate exposed on site, saving installation
pipework or low level ducting. The 110mm time. Comes complete
unventilated PVCu drain is terminated at finished with pre-chamfered spigot
tail for easy jointing.
floor level with a reducer and boss adaptor to suit SY401
the size of waste from the appliance. Branch
SCBL41 – 350mm
Long spigot tail,
accommodating virtually Min.trap seal Max. length
Appliances Dia (mm) Pipe gradient (%) Max. bends (No.) Max. drop H (m)
all floor thicknesses. depth (mm) of pipe (m)
SA411/421/420
32mm/40mm
or 50mm SFC110 fire collar, Washbasin or bidet 32 75 1.7 2.2 0 0
2.5m
Boss connector max SFW44 pipe wrap can Washbasin or bidet 40 75 3.0 1.8 to 4.4 2 0
be used within the
floor slab. Bath or shower 40 50 No limit 1.8 to 9.0 No limit 1.5
For details on our Bowl urinal 40 75 3.0 1.8 to 9.0 No limit 1.5
1.5m complete fire collar Trough urinal 50 75 3.0 1.8 to 9.0 No limit 1.5
SRM402 Long radius range see page 39 or
max
Eccentric reducer bend UBL488 go to marleypd.co.uk Kitchen sink 40 75 No limit 1.8 to 9.0 No limit 1.5
Dishwasher or washing
40 75 3.0 1.8 to 4.4 No limit 1.5
machine
UB411
Bend WC 110 50 No limit 1.8 min No limit 1.5
SC41 clip fitted
around socket.
The maximum lengths given above may be increased where the branch pipe is ventilated or an air admittance valve is used. For further details refer
to the above standard.

Prevention of cross-flow To prevent cross-flow from a large diameter The Marley Collar Boss was specifically designed to overcome installation problems imposed
branch to a smaller waste connection, the latter by the 200mm restricted zone and to allow multiple low level bath or shower waste pipes to be
Where small diameter branch waste pipes
should be made to the stack at or above the connected to the stack above floor level. Cross-flow is prevented as the circular annular chamber
connect to a discharge stack they must be
centre line of the larger protects the small diameter waste connections from the WC discharge allowing waste water to
arranged to eliminate the risk of cross-flow from
branch, at right angles or flow freely and merge below the critical zone.
one branch to the other. A branch creates a
at least 200mm below the
no entry zone for opposing waste connections, Different combinations of 110mm branches can be used with the collar boss to accommodate
restricted zone. Entry is
which varies depending on the stack diameter. various WC positions which may be up to 3 metres from the vertical stack. SY401
permissible on the boundary
No connections should be made within the Branch
SWS40 centre line directly opposite
restricted zone although entry is permissible
Boss pipe or at right angles.
on the centre line of the boundary directly
opposite or at right angles.

H
Stack size Height of zone 'H'
200mm
(mm) (mm)
SA421 SCB41
Boss adaptor SY405 Collar boss
82 90 branch
SA421
110 110 Boss connector
160 250

‘H’ = 200mm irrespective of stack diameter

34 | MARLEY PVC Soil & Waste All documentation is available to download from marleypd.co.uk Technical hotline: 01622 852695 MARLEY PVC Soil & Waste | 35
Design

Combined branch waste Waste traps WC manifold system


A combined branch waste is often used to Generally appliances such as sinks, baths and The Multikwik anti-vac bottle trap, B032V Developed for use in sanitary pipework systems the minimum distance between the end of the To accommodate different dimensions
connect a bath and/or shower and basin to the showers do not suffer from self-syphonage / B040V, was specially developed to prevent in schools, hospitals, public and commercial WC spigot and the face of the wall is 150mm. between the WC spigot and horizontal float,
discharge stack as this allows waste pipework as the trap seal is replenished at the end self-syphonage from basins, which can occur buildings, the manifold system allows ranges To facilitate varying angles and gradients the the adjustable spigot bend SM43W may be
to be neatly concealed in a low level duct. of the discharge due to the flat bottom particularly where the waste pipe drops of toilets to be connected to a horizontal float 110 x 90mm manifold branch has a radial trimmed by up to 35mm or the extension pipe
design of the appliance. Tubular traps are vertically from the appliance before falling above floor level and eliminate the need for socket to match both options of adjustable SM45W can be used with the pan connector
Where this technique is adopted a 45° entry tee
recommended for such appliances as they at an even gradient to the discharge stack. specially fabricated fittings. WC bend. When the selected bend is cut to SM44W and SA323W cap & seal.
must be used to ensure the basin discharge is
ensure unrestricted discharge and reduce the the appropriate line and solvent welded into
swept in the direction of flow towards the stack. The trap also eliminates the need for a The components are suitable for installation in The WC socket on both the SM42W and
risk of blockage and prevent the accumulation the socket on the manifold branch a uniform
The minimum distance between the bath or secondary vent pipe where basins are located a duct, or for fitting on the surface of the wall SM44W must be trimmed to suit the length
of sediment. fall is obtained between each toilet on the
shower and basin connection should not be less further than the recommended 3m maximum directly behind the pan. Where the manifold of pan spigot before the SA323W is fitted.
horizontal float.
than 500mm and it is recommended that an  ompression jointed polypropylene traps
●● C from the stack. Non-mechanical, the trap is fitted directly behind the range of toilets,
For installation details see page 45.
anti-syphon bottle trap is fitted to the basin or can be taken apart to remove a blockage operates as air is drawn in through a by-pass
a vent provided to protect the appliance from or gain access to the waste system tube to eliminate any syphonic action and
self-syphonage. ensure the trap seal is maintained.
●● R ange includes P-traps, S-traps, bottle
traps, bath & shower traps and different It is recommended its use is restricted
It is recommended that the distance of the SM42W
configurations for washing machines, to ground floor baths and showers that & SA323W
combined waste does not exceed 3 metres,
dishwashers, 1½ or 2 bowl sinks discharge directly to an external trapped
however, experience has shown that longer runs
gully. It should not be fitted to a bath or
using 40 or 50mm pipework has proved successful ●● White with multiple seal depths
shower where the waste pipe is connected
provided adequate fall can be obtained to ensure centre line of WC outlet SM41W
●● Sizes: 32, 40 and 50mm to a soil stack.
self-cleansing velocity is maintained from finished floor level
B032V
Anti-vac
bottle trap

190mm
Now available from

P6040 low
level trap 110mm float at
KT21W entry tee
SWS41 9mm/metre fall SY401/SY405
KBA22W branch
Bath/ boss pipe
45º bend
Shower

40mm SM42W
500mm min
adjustable bend

30
35
B
Manifold branch SM41W with SM42W 215mm minimum Manifold branch SM41W with SM43W
duct width

Cut line 50° 55° 60° 65° 70° 75° 80° 85° 90° Adjustable wall fixing Cut line SA323W 50° 55° 60° 65° 70° 75° 80° 85° 90°
cap & seal

A – projection (mm) 93 93 92 91 90 87 84 80 75 Flush plate


A – projection (mm) 180 180 179 178 177 174 171 167 162
SM41W
B – drop (mm) 69 77 85 93 101 109 116 123 130 B – drop (mm) 69 77 85 93 manifold
101 109 116 123branch
130
W.C. Cistern

Front panel

W.C. Frame
W.C. seal & cap
SA323W
A
A
Flush pipe SA323W cap & seal
A
SM42W
adjustable SM43W
SM43W
WC bend SM42W
SM42W adjustable spigot bend
adjustable
SM43W WC
adjustable
adjustablebend
WC bend WC bend
spigot bend
SM41W
Manifold branch

30
35
SM41W
30

JB42 two peice pipe


35

manifold branch B
bracket with SC621 B
barrel clip collar 110mm float
SA323W
SA323W SM41W
SA323W
SA323W capcap & seal
& seal SM44W
cap
cap&&seal
seal manifold
110 x 90mm branch SM41W Adjustable bend SM42W with socket SM41W pan connector branch
trimmed to suit 50mm pan spigot manifold SM44W
JB42 two peice pipe bracket Adjustable bend SM42W with socket SM41W
SM41W
branch pan connector
manifold branch with SC621 barrel clip collar trimmed to suit 50mm pan spigot manifold branch

36 | MARLEY PVC Soil & Waste All documentation is available to download from marleypd.co.uk Technical hotline: 01622 852695 MARLEY PVC Soil & Waste | 37
Design

Durgo air admittance valve Fire protection


The Durgo valve is designed to reduce the When installed the valve will remain closed For up to and including four dwellings, 1, 2, or The Building Regulations 1991 (as amended) The test work and technical evaluation was The construction illustrated below achieved a
number of ventilating pipes and subsequent roof unless the system is subject to negative 3 storeys in height, additional drain venting is require that a building shall be sub-divided into independently assessed by the British Board of 1½ hour fire resistance rating without the need
penetrations in domestic, commercial and public pressure whereby the diaphragm will lift and not required. Where a drain serves more than compartments where necessary to inhibit the Agrément who issued an Agrément Certificate. for a fire resistance enclosure. The enclosure is
buildings. Suitable for use in sanitary pipework allow air to be drawn in to eliminate syphonic four such dwellings equipped with the valve, spread of fire. Plastics pipework is permitted Copies of this original certificate and the detail necessary to achieve a 2 hour rating.
systems up to ten storeys high, the valve must action. Positive pressure ensures the valve the drain should be vented according to the to penetrate separating walls, compartment sheets are available from Marley Plumbing &
be fitted in a vertical position above the flood closes and prevents foul air escaping from the following rules: walls and floors provided the appropriate Drainage.
level of the highest appliance connecting to system. Each valve is supplied boxed with a measures are taken to prevent the spread of
5 to 10 such dwelling – conventional ventilation
the stack. Valves should be installed within polystyrene insulation cover that should remain fire in accordance with Part B of the Approved
to be provided at the head of the system.
the building in a ventilated duct or roof space in position after installation, as this will protect Document (2010).
where there is no risk of freezing and must be the valve against freezing, particularly when 11 to 20 such dwellings – conventional
To comply with this, pipes must be enclosed
accessible for inspection and testing. installed in a roof space. ventilation to be provided at the mid-point SVD4 Durgo air
within a fire resistant enclosure which extends admittance valve
and at the head of the system.
The 50, 82 and 110mm size valves have been To ventilate the underground drainage system from floor to ceiling within each storey. The
assessed by the British Board of Agrément and and to minimise the effects of back pressure For multi-storey domestic dwellings (other than enclosure must have a class ‘O’ internal surface SE400 pipe
those referred to previously) and non-domestic socket
awarded Certificate No 06/4325 which permits should a blockage occur, the branch or main and have each side formed by a separating
their use in accordance with the Building drain serving a stack or stacks fitted with Durgo buildings, conventional drain venting should wall, external wall or by casing. Any casing must
Regulations. A copy of the full certificate valves may require conventional venting at be provided if more than one such building, have a minimum ½ hour fire resistance and
is available and provides comprehensive a point upstream of the stack connection. each equipped with the valves, is connected penetrations of the duct must be limited to
information on their use and installation. to a common drain which itself is not vented 160mm vertical and 110mm horizontal. SGS41/SA323W
by means of a ventilating stack or a discharge WC pan connector
Where longer periods of fire resistance are
stack not fitted with a valve. SW40
required, Marley fire collars or pipe wraps can boss pipe
Stacks should not be fitted with valves when be fitted. For further details please refer to
11 to 20 dwellings SVP at head and mid point
the connecting drain is subject to periodic marleypd.co.uk
5 to 10 dwellings SVP at head surcharging or is fitted with an intercepting
Tests carried out at FIRTO on a variety of typical
Up to 4 dwellings no SVP required trap. An open vent must be provided and
sanitary pipework arrangements proved that
this also applies to stacks that discharge to
it was possible to achieve up to 1½ hour fire
SVP Durgo SVP Durgo Durgo Durgo a cesspool or septic tank. SY401
rating through a compartment floor without branch
a fire collar or pipe wrap where the stack
was terminated by an air admittance valve.
Various other arrangements were also tested
and achieved a minimum of 2 hours integrity.
20th 11th 10th 5th 4th 1st

Indicative row of 20 dwellings 3 storeys high (maximum) fitted with Durgo valves Floor and enclosure fire stopped at all openings using
materials meeting building regulation requirements

Typical fire collar installation


BASIN FLOOD LEVEL SVD4-110mm
B1 rated valve
fitted above 1 2 3
SE400 Coupling flood level
or pipe socket of basin

SC45 Pipe clip

B032V 110mm PVCu pipe


Anti syphon bottle trap
KR210 reducer SVD3-82mm
A1 rated valve
fitted below
flood level Remove retaining pin and Slide tab through slot in pipe Secure collar by drilling holes
SWCB90 SRM304 110x82mm of basin position collar around pipe. collar and fold back 180° to in structure.
90° connector Level invert reducer
secure.
40mm dia

BATH/SHOWER SYS415 4 5
87.5° Branch
P1940 KBA22
Low level 'p' trap 45º bend
40mm dia

F.F.L. For further details of Marley fire collars,


please go to marleypd.co.uk
KT21 2no 45° Bend SA421 SCBL41
45º tee KBA22/KB22 Boss connector Collar boss Fix using M8 x 65mm sleeve Completed installation.
anchors of 50mm (min)
expanding bolts.

38 | MARLEY PVC Soil & Waste All documentation is available to download from marleypd.co.uk Technical hotline: 01622 852695 MARLEY PVC Soil & Waste | 39
Installation data

Jointing techniques
The ring seal has been successfully employed as Solvent soil stack installation Push-fit soil stack installation
the principal method of jointing large diameter
The addition of the SE409 ring seal adaptor allows for thermal
PVCu pipes and fittings since their introduction
movement required in a solvent soil installation
over thirty years ago. This particular technique
has proved extremely reliable as the joint can
accommodate thermal movement that will
occur as a result of temperature variations. An SES401 SC41
expansion gap of between 5-10mm should be Double solvent coupling Socket/support clip
SC41 Anchor point
allowed within each ring seal socket as each full SES401
Socket/support clip SC41
length of pipe is installed and fixed using socket Double point
Anchor solvent coupling Socket/support clip
SC41 Anchor point
and barrel pipe clips. Socket/support clip
Anchor point
Solvent weld jointing is also widely used and
many components in the range are available Ring seal joint
with this facility to provide an effective
alternative. By selecting these fittings a solvent
Solvent weld joint
weld system can be installed, however, ring
seal joints must be incorporated to control
thermal movement.
While the most popular method of jointing

MAX 2000mm

MAX 2000mm
larger size PVCu pipes and fittings is by ring
seal, with small diameter waste pipework the

MAX 2000mm

MAX 2000mm
principal choice is usually solvent weld. Where
this technique is used expansion couplings
must be introduced where pipe lengths exceed
1.8 metres or between fixed points. The same
40mm waste pipe Expansion coupling KEC2
principle should also be adopted when the
polypropylene push-fit waste system is installed.
It should be noted that polypropylene cannot SFS41 SFS41
Access pipe Access pipe
be solvent welded and together with the ABS
waste system must not be fitted externally SFS41 SFS41
Access pipe Access pipe
unless painted to protect it from ultra-violet pipe clips
degradation.
For installation using solvent cement please see 5 to 10mm 5 to 10mm
Expansion gap Expansion gap
marleypd.co.uk SC45 SC45
Pipe/barrel clip 5 to 10mm Pipe/barrel clip
5 to 10mm
Guide bracket Expansion gap Guide bracket
Expansion gap SC45 SC45
SE409
Pipe/barrel clip Pipe/barrel clip
Ring
Guideseal adaptor
bracket Guide bracket

Pipe support Connection


SE409
SYS405
Connection
SY401
Ring sealbranch
110mm adaptor 110mm branch
Experience has proved that an efficient and from W.C from W.C

reliable PVCu sanitary pipework system depends SCB41


SYS405 SC41SY401
Connection Connection
Connection from Collar boss branch
110mm Connection from Collar boss branch
110mm
considerably on the attention that is placed from W.C
bath/shower
from W.C
bath/shower
on the correct provision of pipe support SCB41 SC41
Connection from Collar boss Connection from Collar boss
brackets. This is particularly important in multi- bath/shower bath/shower
storey buildings where care must be taken to
ensure clips are positioned to control thermal
movement at each floor level.
Plastic coated metal socket clips are designed
to fit ring seal sockets and act as anchor
brackets. These used in conjunction with PVCu
intermediate pipe clips, control expansion and Barrel pipe clip SC45 Socket pipe clip SC41
Pipe material BS Nominal pipe size Horizontal support (m) Vertical support (m)
contraction and maintain the vertical alignment
of the stack.
PVCu 21.5 0.50 1.20
Two piece socket clips SC41/61 may be adapted pp 32 0.50 1.20
to suit the appropriate pipe size by using a
40 0.50 1.20
section of barrel clip collar SC621 to provide
PVCc 32 0.50 1.20
the necessary spacer sleeve. The table opposite
indicates the maximum recommended support ABS 40 0.50 1.20
centres of different size plastic pipe systems. 50 0.60 1.20
PVCu 82 1.00 2.00
110 1.00 2.00
160 1.20 2.00

40 | MARLEY PVC Soil & Waste All documentation is available to download from marleypd.co.uk Technical hotline: 01622 852695 MARLEY PVC Soil & Waste | 41
Installation data

Marley pipe support system Boss branches


The Marley pipe support range was developed to meet the specific requirements of PVCu The Marley range of boss branches are 32, 40 or SA411/421/420
suspended sanitary pipework and drainage systems. Manufactured in zinc electro plated mild designed to allow multiple waste pipe 50mm pipe boss connector
steel for internal use, the versatile range of components can be assembled to provide a robust, connections to be made to the discharge
lightweight system suitable for most applications. The system also provides suitable control of stack from different directions. Four different
expansion and contraction. side entry combinations are possible together
with a rear if required. Staggered waste
The arrangements of brackets and channel supports have been extensively tested and the assembly
pipe connections, directly opposite are not
techniques used have been successfully employed on many domestic and commercial installations.
permitted as cross-flow could occur.
Single support
Recommended for waste or larger diameter pipework fixed within 500mm of the floor soffit. see table
Compatibility
Double support Boss pipes, boss connectors and strap-on
angle brace
bosses fitted with multi-fit ‘T’ ring seals are
Developed for use with larger diameter pipework fixed within 1.0m of the floor soffit.
suitable for use with PVCc or ABS waste systems
Pipe brackets 500mm max. to BS EN 1566 or BS EN 1455-1, polypropylene
or 600mm with SY405 SA411/421/420 SY405 KBK25 or KBK35
to BS EN 1451-1 and metric size copper to branch boss connector branch knuckle bend
The 110mm two piece pipe brackets are designed to fit round the ring seal socket ofside
a pipe
bracingor
110mm pipe BS EN 16090.
fitting. Where intermediate support brackets are located, the SC621 PVC barrel clip collar is used
as a spacer sleeve between the pipe and bracket. anchor bracket Un-perforated boss upstands on boss pipes,
branches and reducers may be drilled to accept
Angle and side bracing 32, 40 and 50mm boss connectors SA411, SA411/421/420 SA411/421/420
intermediate bracket
Angle braces should be provided at 6m centres to prevent lineal and thermal movement. Side SA421 and SA420 using a 51mm diameter hole boss connector boss connector
bracing may also be necessary on long runs where there are no side connections to eliminate saw. Knuckle bends KBK25 and KBK35 may also
lateral movement. be used as 90° boss connectors for 40 and
50mm PVCc or ABS waste pipework.
Vertical pipes
The transition between vertical and horizontal pipework should be achieved using two 45° bends
or a single 87½° long radius bend with a support bracket positioned as close as possible.
Horizontal connections
The SWS4135 boss pipe is recommended for
Branch connections use in horizontal situations where connections
1.2m max.
All branch connections into horizontal pipework should be made at 45° to ensure the discharge to 110mm diameter pipe is made at 45°.
angle brace
is swept in the direction of flow. This fitting has a 50mm solvent weld socket
to accept PVCc or ABS waste pipes.
Structural fixings 750mm max.
It is recommended that 6mm rawlbolt or similar proprietary fixings are used to secure base or 1.0m with
plate
side bracing SY405 SY405 32, 40 or
and angle cleats to the structure. branch branch 50mm pipe
intermediate
bracket 110mm pipe

anchor bracket

1.0m

Single support Double support Boss pipe connections


Four different types of fitting are available to provide alternative methods of connecting small diameter waste pipes to 82, 110 and 160mm vertical
discharge stacks.
110mm 110mm
Single boss pipes. Strap-on-bosses.
see table
see table
Available with ring seal or solvent Primarily designed to permit 32, 40
weld sockets for push-fit or solvent and 50mm waste pipe connections
angle brace
weld jointing, single boss pipes to be made to existing 110mm PVCu
angle brace allow 32, 40 and 50mm waste pipe discharge stacks, strap-on-bosses
500mm max. connections to be made at 87½° SWS415/ can also be used on new systems to SWS4150
or 600mm with SWS41 /410/420
side bracing 1.0m max.
direct to the vertical stack. provide flexibility of installation during
110mm pipe or 1.2m with different stages of construction.
side bracing
110mm pipe
anchor bracket
anchor bracket SW30/40
82mm
Multiple entry boss pipes. boss branch Patch bosses.
intermediate bracket

intermediate bracket Supplied in ring seal or solvent weld SA411/421/420


Suitable for solvent weld jointing to
SWS332
options, all have 90° boss upstands boss connector new and existing 82mm diameter /340/350
moulded on each fitting with one PVCu discharge stacks to accept
inlet port open. Connection is made 32, 40 and 50mm size PVCc or ABS
using the appropriate size Marley waste pipework.
boss connector to suit 32, 40 or
50mm waste pipes. 32, 40 or 50mm pipe

1.2m max.

angle brace

42 | MARLEY PVC Soil & Waste All documentation is available to download from marleypd.co.uk Technical hotline: 01622 852695 MARLEY PVC Soil & Waste | 43
750mm max.
or 1.0m with
110mm 110mm ST40W SWCB90 SWCB90
ST40W 110mm 110mm
push-fit WC push-fit WC
solvent solvent
connector connector
WC connector WC connector
Installation data 110mm ST40W 110mm
SWCB
push-
solvent
conne
WC connector

MORE WC
WC connections
Two different types of connectors are available to allow connection to connectors are used, the WC socket must be trimmed to suit the length
vitreous china or stainless steel WC pans, slop hoppers and other similar of pan spigot before the SA323W is solvent welded in position.
sanitary equipment. Manufactured in PVC and eva (ethylene vinyl acetate)

CONNECTORS
Ground floor toilets often have their own connection to the building
to accommodate a range of outlet sizes between 84 and 110mm sanitary
drain to eliminate pipework and ducting. Where this occurs both types
pipework or underground drainage.
of connector are suitable for push-fit or solvent weld jointing to the
SGS41W SGS41W
The 90º ST40W, ST41W and SG40W connectors are supplied complete 110mm PVC drain.
110mm solvent
with flexible seal and110mm
solvent 110mm
retaining cap. Where the SGS41W or STS41W pan110mm
WC connector WC connector
110mm SWCB90

FROM MULTIKWIK
ST40W 110mm
push-fit WC
solvent
SWCB90 SGS41W connector
110mm ST40W WC connector
110mm
push-fit WC solvent
110mm 110mm
solvent WC connector
connector
WC connector
SWC11 SWC11
SA323W SA323W push-fit push-fit
WC seal and WC seal and WC connector WC connector
retaining cap retaining cap

Multikwik's comprehensive SWC11


SA323W push-fi
range of WC connectors is one WC seal and WC con
retaining cap
of the largest on the market,
and covers spigots of 74mm –
114mm, ensuring an accurate SGS41W
110mm
SWCB90 solvent 110mm
fit, regardless of the make and 110mm ST40W 110mmSGS41W
push-fit WCWC connector
solvent
model of sanitary chinaware. WC connector
110mm solvent connector 110mm
WC connector

For more information go to


marleypd.co.uk SWC11
SA323W push-fit
WC seal and SWC11 WC connector
SA323W retaining cap push-fit
WC seal and WC connector
retaining cap

ST40W ST40W SWCB90 SWCB90


solvent WC connector
solvent WC connector push-fit WC connector
push-fit WC connector
SGS41W
110mm solvent 110mm
WC connector
ST40W SWCB90
solvent WC connector push-fit WC conne

SWC11
SA323W push-fit
WC seal and 110mm 110mm
WC connector 110mm 110mm
retaining cap PVCu drain PVCu drain PVCu drain PVCu drain

multikwik.com
110mm 11
PVCu drain PV

44 | MARLEY PVC Soil & Waste ST40W


All documentation is available to download from marleypd.co.uk Technical hotline: 01622 852695 SWCB90 MARLEY PVC Soil & Waste | 45
solvent WC connector push-fit WC connector
Installation data Site Work

WC manifold system Inspection and testing Handling Safety


Inspection and testing should be carried out in PVCu pipes are strong, though lightweight The relevant regulations are outlined in the
accordance with BS 12056: 2000 and Building and therefore very easily handled. However, Health and Safety At Work Act 1974 and
Up to six WCs can be connected to a soil stack using the WC manifold system and a single branch NUMBER ANGLE OF MANIFOLD BRANCH Regulations noting especially the details given reasonable care should be exercised while The Construction (Design and Management)
connection. By using a double branch connection, an additional six WCs can be connected. OF WCs
WC 1 WC 2 WC 3 WC 4 WC 5 WC 6 in respect of air testing and the fact that smoke handling, particularly in extremely cold conditions. Regulations 1994 and should be followed.
The table, right, details the angles of the manifolds for this installation. 6 80° 75° 70° 65° 60° 55° testing of plastics pipework should be avoided Pipes should preferably be loaded and unloaded Hazard sheets, dealing with the correct
5 75° 70° 65° 60° 55° as the materials can be adversely affected. by hand but if mechanical handling is used, storage, use, and any hazards of working
protected slings are recommended. with solvent cement, silicone lubricant and
4 70° 65° 60° 55° Air test fire protection products are available from
3 65° 60° 55° The installation should be capable of Maintenance Marley Plumbing & Drainage.
2 60° 55° withstanding an air test of positive pressure Provided that the system is designed and installed
of at least 38mm water gauge for at least 3 correctly, no maintenance will be required.
minutes. During this time every trap should
If blockage does occur, use only flexible or roller
maintain a water seal of at least 25mm.
450mm 900mm 900mm 900mm type rods. Pointed or bearing type metal fittings
are not recommended. Tests have been carried
70° 65° 60° 55° out on PVCu pipes and fittings using equipment
*126mm

from specialist drain cleaning contractors and


their standard equipment is suitable.

F.F.L
Dimension (*) based on 190mm centre outlet WC pans and SM43W adjustable spigot bends cut to the angles shown.

1. Select the adjustable bend angle required 2. File away any rough edges from the face 3. Apply a uniform coat of Marley solvent
from the above diagram according to the of the fitting and wipe clean the bend and cement, to the short branch radial Storage
WC position. Cut the bend with a hacksaw, branch, with a dry cloth. Before jointing, socket and to the external surface Pipes should be stacked on a reasonably flat, sockets at alternate ends protruding to ensure
removing the unwanted portion. the bend and branch should be checked for of the bend body. level surface on timber battens not less than pipes are evenly supported along their length.
position and alignment, both parts being 75mm wide spaced at a maximum of 1m
Pipes should not be stacked more than 7 high
marked to ensure accurate assembly. centres. Side support should also be provided
and when stored in the open for long periods,
at intervals of not more than 1.5m.
or exposed to strong sunlight, they should be
Different size pipes should be stacked separately. covered with an opaque sheet. Fittings supplied
SM41
However, where this is not possible, larger in cardboard boxes or polythene bags should
diameter pipes should be placed at the bottom. be stored under cover and kept packed until
required. Solvent cement should be stored in
Spigot and socket pipes should be stacked
a cool place out of direct sunlight and away
separately. However, where this is not possible,
from any heat source.
larger diameter pipes should be stacked with

SM42/SM43 SM42/SM43 SM42/SM43

4. Assemble the branch immediately, insuring 5. Trim the WC socket to suit the toilet pan To accommodate varying dimensions between
that the marked lines on the fitting coincide. spigot length and remove any swarf with the WC spigot and the centre line of the
Do not twist the two parts of the branch a file. Place the seal in the socket, apply a horizontal pipe run, the adjustable spigot bend
during this operation, but maintain steady uniform coat of solvent cement about 15mm SM43 or extension pipe SM45 can be used with
pressure until the spigot of the bend comes wide to the outside of the socket and inside WC connector SM44.
to rest against the internal surface of the the retaining cap. Push onto the socket and
branch socket. Quickly wipe off any surplus wipe off any surplus solvent cement.
solvent cement from the inside and outside
of the completed joint and hold in position
for approximately 15 seconds.

SM41
SM41

SA323
cap and seal

SM42/SM43
SM42/SM43

46 | MARLEY PVC Soil & Waste All documentation is available to download from marleypd.co.uk Technical hotline: 01622 852695 MARLEY PVC Soil & Waste | 47
Standards Key

British & European Standards


BS EN 1329-1: 2014 BS EN 1566-1: 2000 BS EN 14680: 2006 ABS = Acrylonitrile butadiene styrene
Plastics piping systems for soil and waste Specification for thermoplastics waste pipe Specification for adhesives for non-pressure PVCu = Poly vinyl chloride un-plasticised
discharge (low and high temperature) and fittings. thermoplastics pipe systems.
PP = Polypropylene
within the building structure – PVCu.
BS 5255: 1989 BS EN 681-1: 1996
BS EN 1451-1: 2000 Specification for thermoplastics waste pipe Elastomeric seals. Material requirements for
Plastics piping systems for soil and waste and fittings. pipe joint seals used in water and drainage
discharge (low and high temperature) within applications. Part 1 vulcanised rubber.
the building structure – polypropylene. BS EN 1455-1: 2000
Plastics piping systems for soil and waste BS EN ISO 9001: 2008
BS EN 1519-1: 2000 (low and high temperature) within the Quality systems. Model for Quality
Plastics piping systems for soil and waste building structure – ABS. Assurance in Design, Development,
discharge (low and high temperature) within Production, Installation and Servicing.
the building structure – polyethylene. BS 5627: 1984
Specification for plastics connectors BS EN ISO 14001: 2004
BS 4514: 2001 for use with horizontal outlet vitreous Environmental management systems.
Specification for PVCu soil and ventilating china WC pans. Requirements with guidance for use.
pipes, fittings and accessories.

Accreditations
ER INDUSTR
AT
TIFIE TO W

Y
SP
ECIFICAT
D
ER

ON
I

Certificate No. 06/4325 BS EN 1329-1 : 2000


BS 4514 : 2001 BS EN ISO 9001: 2008
BS EN 1566-1: 2000 BS EN ISO 14001: 2004
BS 5255: 1989
BS EN 1455-1: 2000
BS EN 1451-1: 2000
BS EN 1519-1: 2000

48 | MARLEY PVC Soil & Waste All documentation is available to download from marleypd.co.uk Technical hotline: 01622 852695 MARLEY PVC Soil & Waste | 49
Marley system solutions
Technical Services:
Here to help.
Years of experience mean that we can support you Below are just a few examples of the
technical services we offer:
throughout your tender process and assist with any
technical and installation requirements. ESTIMATES ££ COST
REDUCTION

What technical services do we offer you? TECHNICAL FIELD AND


Q&A SITE SUPPORT HDPE soil Acoustic soil Marley rainwater
Designing the most efficient drainage system for a project is a Marley Akatherm HDPE is a drainage An acoustic soil and waste range with Five gutter profiles and three downpipe
skill for which the Marley Technical Services team are renowned. SPECIFICATION RAINWATER system which offers an alternative solution a layered pipe providing quick, hygienic options provide a rainwater solution
CALCULATIONS
to cast iron. It is particularly suited for removal of sanitary waste water. for any application. Advanced Life4
Marley Plumbing & Drainage provide technical support to all those technology on four of the key profiles,
CAD SPECIAL commercial applications or where a The noise generated by the flow of water
involved with the specification and installation of their products. FILES FABRICATIONS
product with high impact or abrasion is dramatically reduced – making it perfect coupled with the benefits of the Easyclip
resistance is required, such as hospitals, for multi-occupancy apartment blocks and notching capability combine to make
Customers who made a commitment to use Marley Plumbing and BIM FABRICATIONS
OBJECTS SERVICE hotels, schools, as well as residential and high specification developments. the Marley rainwater range the most
Drainage products may benefit from the free design service which comprehensive available.
buildings. HDPE will also cope with
is offered for above ground drainage and rainwater systems. IN-HOUSE
DESIGN AND EXTERNAL temperature variations of -40°C to
SERVICES TRAINING 100°C making it ideal for external
MATERIAL CPD as well as internal installations.
For further information visit marleypd.com TAKE-OFFS SEMINARS

and select ‘support and advice’.

Marley underground systems Alutec Multikwik


The Marley Plumbing & Drainage range Alutec offer modern and traditional The Multikwik brand is known and trusted
of underground systems include the aluminium rainwater profiles, providing by plumbers for its sanitary frames, cisterns,
solid wall range, predominately for solutions for any type of building. traps, compression waste systems and
round the house drainage and Quantum Aluminium has high visual appeal and market leading range of pan connectors.
structured wall range for sewer and durability, lasting for 50 years or more. Complementing the Marley range it
highway drainage applications. The product portfolio includes Evolve; provides an excellent solution to modern
easy to install, low cost gutter systems bathroom design with a wide choice
in four profiles. The rainwater ranges are of product options.
complemented by aluminium soffit and
fascia systems and roof & floor outlets.

50 | MARLEY PVC Soil & Waste A full technical design and installation guide is available to download from marleypd.co.uk Technical hotline: 01622 852695 MARLEY PVC Soil & Waste | 51
marleypd.co.uk
For general enquiries and details of your
nearest stockist please call the customer
services department:
Tel: 01622 852585
Email: marketing@marleypd.com

To place an order
For delivery to England & Wales
Email: orders.lenham@marleypd.co.uk
Fax: 01622 851111
For delivery to Scotland
Email: orders.uddingston@marleypd.co.uk
Fax: 01698 810307

For all estimate requests


Email: estimates@marleypd.co.uk

For Technical advice please call


01622 852695

Head Office
Lenham, Maidstone
Kent ME17 2DE
Tel: 01622 858888
Fax: 01622 858725

Scotland
Birkenshaw Industrial Estate
Uddingston, Glasgow G71 5PA
Tel: 01698 815231
Fax: 01698 810307

Export Division
Lenham, Maidstone
Kent ME17 2DE England
Tel: +44 (0)1622 858888
Fax: +44 (0)1622 850778