BLT 1200 DC Power System Platform
Rectifiers
Tebechop hot-plug
Tebechop 1800
48 V - 33 A
Tebechop 4000
48 V - 75 A
24 V - 100 A
Key Features
Efficiency
93
92
91
90
89
88
hot-plug
Tebechop hot-plug rectifiers can be 0
easily user installed and removed
without effecting system operation. 0 25 50 75 100 [%]
Output current
Sub-Rack
BLT 1200
Output current: 600 A
Output voltage: 48 V
Controling: MCU 1000
BLT 1200
Output current: 300 A
Output voltage: 48 V
Controling: MCU 1000
Dimensions
H 950 x W 600 x D 600 mm
BLT 1200
Output current: 1000 A
Output voltage: 48 V
Monitoring: MCU 2000
AC input
Option: over voltage suppressors
Max. 24 (16)
circuit breakers
Max. 24 (16)
circuit breakers
Max. 24 (16)
circuit breakers
Max. 6
Rectifiers 48 V - 50 A
Dimensions
H 2000 x W 600 x D 600 mm
Dimensions Dimensions
H 2000 x W 600 x D 600 mm H 2000 x W 600 x D 600 mm
DC-Power-Systems BLT 1200
Type table, Rectifiers hot-plug
Output current
at 24 V [A] 40 I – I 100 I –
at 48 V [A] 33 I 50 I 75 I 100
Output voltage
Protection IP 20
Dimensions
Power System Monitoring MCU 500, MCU 1000 and MCU 2000 +
Fload
Boost DC Power Supply
Battery test
Battery test negativ
Rectifier failure
Mains failure
Fault U < 2,1 V/Z
Fault U < 1,9 V/Z
LVD tripped
Battery fuse blown
Load fuse blown
Battery fault
Reserve
LED Test/Reset
MCU 500
LED Test/Reset
MCU 2000 +
The front panel of the MCU 500, The Tebechop hot-plug rectifier modu-
1000, and MCU 2000+ feature 13 les communicate to the MCU via the
LEDs and an alphanumerical dis- internal RS-485 bus.
play providing a fast overview
regarding the basic data including The system information from the
alarm messages. Included within MCU 1000 or MCU 2000+ can be
the MCU 1000 and 2000+ are transmitted remotely via an optional
embedded features including fail- telephone modem or through communi-
safe battery test function, tempe- cation via Internet/Intranet to a central
rature compensation, and enhan- control station.
ced maintenance features.
BENNING World Class Power Systems
www.benning.de
BENNING worldwide
Austria India Russian Federation
Benning GmbH Elektrotechnik und Elektronik Benning SMC Power Systems (P) Ltd. OOO Benning Power Electronics
Eduard-Klinger-Str. 9 10, Electronic City, Sec.-18, Schtscholkovskoje Chaussee, 5
A-3423 St. Andrä-Wördern IND-Gurgaon -122015, Haryana RF-105122 Moscow
Tel. 0 22 42 / 3 24 16-0 Tel. 0124 / 6 45 52 03 – 09 Tel. 0 95 / 9 67 68 50
Fax 0 22 42 / 3 24 23 Fax 0124 / 6 45 52 12, 6 34 64 65 Fax 0 95 / 9 67 68 51
E-Mail: info@benning.at E-Mail: smcel@del2.vsnl.net.in E-Mail: benning@mtu-net.ru
ISO 14001
43, avenue Winston Churchill Via E. Mattei, 7 Industriestrasse 6
B.P. 418 I-40138 Bologna CH-8305 Dietlikon
F-27404 Louviers Cedex Tel. 0 51 / 53 19 55 Tel. 01/ 8057575
Tél. 02 / 32 25 23 94 Fax 0 51 / 53 09 23 Fax 01/ 8057580
Fax 02 / 32 25 08 64 E-Mail: benning.energia@libero.it E-Mail: info@benning.ch
E-Mail: info@benning.fr
E-Mail: info@benninguk.com