Você está na página 1de 1
De Roe uma ICC-ES Evaluation Report ESR-2037 Reissued June 1, 2013 This report is subject fo renewal July 1, 2015. www.iec-es.org | (B00) 423-6587 | (562) 699-0543 A Subsidiary of the Intemational Code Gouncil® DIVISION: 03 00 00—CONCRETE ‘Section: 03 37 00—Specialty Placed Concrete REPORT HOLDER: EMMEDUE SPA VIA TONIOLO 38/6, Z|. BELLOCCHI 51022 FANO (PU) ITALY (0039) 0721 855660 www. md infosmdue.it EVALUATION SUBJECT: EMMEDUE WALL, FLOOR AND ROOF PANEL 4.0 EVALUATION SCOPE Compliance with the following codes: '§ 2012.and 2008 Intemational Building Gode® (IBC) 1 2012 and 2008 Intemational Residential Gode® (RC) Properties evaluated: = Structural 1 Surtace-buming characteristics 1 Fee resistance 1 Weather resistance 1 Physical properties 20 usES Emmedve wall oor and roof panels are used 2¢ ciuetural composite panals for load-bearing and norioad-besring conarete walls, and reinroed concrete foot and roof panels in freresistancetated anc non-tre-esistance- fated construcion. The Emmadue panole are recognized for use in buicings of noncombustible constuction wien installed n accordance with Section 4.2 of this repor. 3.0 DESCRIPTION 34 General: ‘The Emmedue panels consist of a single insulating foam Plaste board with a grid of welded wire reinforcement on Gach face of the insulating panel connected by steel ‘ransverse wires. A layer of Shotcrete is applied to each face of the wall panels, over the welded woven steel, at the Jobste. Emmedue wall panels are designated PSMEO and consist of 4inchthick (102 mm) EPS foam cores with ‘rinch-thick (26-4 mm) Shotorete on each outer face. The Emmedue floor-oof panels consist of an insulating foam plastic board with a layer of welded wire remfercement on gach face and a grid of welded wire reinforcement connected by steel transverse wires. The bottom of the floorroof panels is shot wih a layer of Shotorete at the Jobsite, The top of the flocr-roof panels is covered with a layer of placed concrete at the jabste. Emmedue Soor-roat panels are designated PSSE0 or PSS150 and consist, respectively, of 4-inch-thick (102 mm) or S-neh-thick (152 mm) EPS foam cores, with 2 inches of concrete on the top surface and {inch (25.4 mm) Shotcrete on the botiom surface. The Emmedue wall panels and foor-roof Panels sre preformed and delivered to the jobst= for ‘erection and placement of Shoterete and coneretz, 22 Materials: 2.2.4 EPS: The insulaton used in the Emmedue wall, ‘Noor and roof panels i expanded polystyrene (EPS) foam plastic boards manufactured from EPS beads recognized in ICC-ES ESR-1708. The EPS is Type | EPS with a minimum densty of 0.90 pet (14.4 kgim*), a flame-spread index of 25 er less and a smoke-developed index of 480 or Jess whan tested in accordance with ASTM E 84 at a ‘Linch (102 mm) thickness and a 1.0 pef (16.0 kgim') maximum density. 2.22 Reinforcement: Deformed steel reinforcement (bars must have a minimum yield stress of 60 ksi (420 Mpa) and comply with Section 35.3.1 of ACI 318 and IBC Section 1903. Welded plain wire reinforcement must ‘comply with Secton 3.6.2.5 of ACI 212 and IBC Section 1003. The wire used in the fabreation of the welded wre reinforcement and the steel transverse wire conforms to ASTM A 82. The welded wire reinforcement complies with ASTM A 185. 2.23 Conerete: Concrete must be normal-weight concrete, complying wih the apphcable code, having 3 maximum aggregate size of Jy inch (16 mm). 3 minimum slump of 2 inches ($1 mm), and a minimum compressive strength of 2,500 psi (17.2 MPa) at 22 days. The concrete ‘must comply with Chapter 19.ofthe IBC. 2.24 Shotorete: Shotorete must comply with IBC Section 1013 and have a minimum specified compressive strength of 2.500 psi (17.2 MPa). Aggregate size must not exceed “i inch (8.5 mm) and conform fo Gradaton No. 1 of Table 2.1 of ACI S06R-20, a tw ec een hc oa har rats mip need marae We om a {ny fing or ahr em spr, ny prod rar ye pert coomonezo

Você também pode gostar