PILE LOAD CARRYING CAPACITY CALCULATION AS PER PILE LOG AS AVAILABLE FROM
PILE DATA SHEET AS PER SIL/MM/BCISP/Form - 3 dated 20-07-08

P209:
Bore hole considered in design is ABH 57
Friction values as applicable for this bore hole is as follows:

Layer Layer Name Friction value


2
No. kN/m
2a Completely weathered Breccia 150
2b Highly weathered Breccia 200
3 Moderately weathered Breccia 250
4 Slightly weathered Breccia 400

Maximul load on pile is = 3273 kN


= 334 Tons

Pile bore data for Pile No. 1 as per SIL/MM/BCISP/Form - 3 dated 20-07-08 is,
Socket Lenth = 9.40 - 6.91 = 2.49 m for Layer 2b.
Socket Lenth = 11.695 - 9.40 = 2.30 m for Layer 3.
Total socket length = 4.79 m

So pile capacity for Pile No. 1 is,


= (2.49 x 3.14 x200 ) + (2.30 x 3.14 x250 )
= 1564 + 1802 = 3365 kN
343 Tons > 334 Tons
Safe
Pile bore data for Pile No. 2 as per SIL/MM/BCISP/Form - 3 dated 20-07-08 is,

Socket Lenth = 14.20 - 6.20 = 8.00 m for Layer 2b.


So pile capacity for Pile No. 2 is,
= (8.00 x 3.14 x200 ) = 5024 kN
512 Tons > 334 Tons
Safe
Pile bore data for Pile No. 3 as per SIL/MM/BCISP/Form - 3 dated 20-07-08 is,

Socket Lenth = 13.70 - 6.39 = 7.31 m for Layer 2b.


So pile capacity for Pile No. 3 is,
= (7.31 x 3.14 x200 ) = 4591 kN
468 Tons > 334 Tons
Safe
Pile bore data for Pile No. 4 as per SIL/MM/BCISP/Form - 3 dated 20-07-08 is,

Socket Lenth = 11.70 - 5.50 = 6.20 m for Layer 2b.

P209 STATEMENT P209 Pile load capacity calc. - Page 1/2


VAG Corridor MRTS Project

So pile capacity for Pile No. 4 is,


= (6.20 x 3.14 x200 ) = 3894 kN
397 Tons > 334 Tons
Safe

If fifth pile is made at pilecap center, friction capacity of all corner piles from one side will have to be reduced.
Distance of fifth pile from corner pile is 2.12m, thus reduction factor for affected side will be 2.12/3 = 0.70

Thus avg. reduction facor for friction capacity is(1 + 1 + 1+ 0.7)/4 = 0.925
Load carrying capcity for pile No.1 is minimum = 343 Tons
Maximum load on pile with 5 piles is = 272 Tons
Thus with reduction factor, Load carrying capacity of pile No. 1 is = 317 Tons > 272 Tons
Safe

th
Maximum load on 5 pile with 5 piles is = 246 Tons
Load carrying capcity for pile No. 5 = 343 0.7 = 240 Tons
With some end bearing capacity the load carrying capacity of fifth pile shall be OK.
Thus minimum pile length of fifth pile can aleast equal to that of pile P1.

NOTE: End Bearing is neglected conservatively.