M8/M12 Connector

Conforming to
IEC61076-2-101
Fieldwireable Connectors

Reduction in wiring time


The man-hours can be decreased because M8
no exclusive tools (such as solder, crimped
terminal) are required. Also, the wire length
can be adjusted at the site.
M12
QUICKON-ONE P. 14 Piercecon® P. 15

SPEEDCON
Reduction in wiring time
Just insert the connector and
make 1/2 rotation. Knurl

Spring-cage Connection P. 13
Align here.

Make 1/2 rotation.

IP67 (IEC60529) Conforming to IEC60947-5-2


The coloring and number indication to the electrical
connection makes less wrong wiring.

M12

Brown 1

Brown 1 White 2

M8
Black 4
White 2 Blue 3 Black 4 Blue 3

CAT.ES100-73B
It provides the Fieldbus communication unit and input device applicable to
Communication Cable/Connector P. 1 to P. 4

 It has a product lineup applicable to any communication standards.


The SMC Fieldbus (SI) Unit can be connected to the PLC (controller) and communication units of other manufacturers with
cables with connectors and fieldwireable connectors (with shield) applicable to the standards of CC-Link, DeviceNetTM, and
PROFIBUS DP.
PLC

Manifold solenoid valve P. 1 P. 2 P. 3


GW unit

Communication cable Fieldwireable communication connector Terminal plug (Terminal resistor)


It is connected to the communication
port of the communication unit
connected at the end.

Socket (Female) Plug (Male)


1 For CC-Link 3 For CC-Link
9 14
5 For DeviceNetTM 7 For DeviceNetTM
10 For PROFIBUS DP 12 For PROFIBUS DP

For For
DeviceNetTM PROFIBUS DP
(Plug) (Plug/B-coded)
Plug (Male) Socket (Female)
2 For CC-Link 4 For CC-Link
6 For DeviceNetTM 8 For DeviceNetTM
11 For PROFIBUS DP 13 For PROFIBUS DP

 Product Table
Description Application No. SMC part no. Name

For Fieldbus communication 1 PCA-1567720 Communication cable for CC-Link (Socket)


2 PCA-1567717 Communication cable for CC-Link (Plug)

Cable with 5 PCA-1557633 Communication cable for DeviceNetTM (Socket)


connector 6 PCA-1557646 Communication cable for DeviceNetTM (Plug)
10 PCA-1557688 Communication cable for PROFIBUS DP (Socket/B-coded)
11 PCA-1557691 Communication cable for PROFIBUS DP (Plug/B-coded)
For Fieldbus communication 3 PCA-1557617 Fieldwireable connector for CC-Link (Plug/Spring-caged)
4 PCA-1557620 Fieldwireable connector for CC-Link (Socket/Spring-caged)
Fieldwire- 7 PCA-1557659 Fieldwireable connector for DeviceNetTM (Plug/Spring-caged)
able
connector 8 PCA-1557662 Fieldwireable connector for DeviceNetTM (Socket/Spring-caged)
12 PCA-1557701 Fieldwireable connector for PROFIBUS DP (Plug/B-coded/Spring-caged)
13 PCA-1557714 Fieldwireable connector for PROFIBUS DP (Socket/B-coded/Spring-caged)

Terminal For Fieldbus 9 PCA-1557675 Terminal resistor for DeviceNetTM (M12)


plug communication
14 PCA-1557727 Terminal resistor for PROFIBUS DP (M12/B-coded)
Features 1
M8/M12 connector and the sensor/switch connected to them as a total system.
Between Sensor/Switch and Input Device P. 5 to P. 8

 Connection between connectors and products


Pressure switch Fieldwireable connector P. 6 Cable with connector P. 7 Input block
It has a product lineup of the field- The wiring can be changed Input unit manifold
wireable connector that does not accordingly.  Series EX500
need any special tools. Select the input block of the
The lead wires can easily be made into M8/M12 EX500 series according to the
connector by changing the wire length. sensor output specification.

M8 For Piercecon®
connection, see
M8
P. 15
15 19

M12 M12

16 18 M12

• EX500-IE3, 4
For “QUICKON-ONE”
connection, see M8
P. 14 17 18
Auto switch
• EX500-IE1, 2
• EX500-IE5, 6
Manifold solenoid
valve with input/
Y connector P. 8
output unit
The input block reads 2 sensor sig-  Series EX250
nals with one port.
The wires of the auto switch and the pres-
sure switch that has one output type can be
decreased by unifying the signal wires using
a Y connector. M12
M12
M12 M12
x2 • EX250-IE1, 2
20
18 M8

• EX250-IE3
M8/M12 connector
(Fieldwireable/Pre-wired)

M8 M12
x2
21
18

Pre-wired type ∗ 2-input type input block is the M12-type


connector only.

 Product Table
Description Application No. SMC part no. Name

Cable with For 18 PCA-1557769 Cable with M12 connector (4 pins/3 m)


connector sensor 19 PCA-1557772 Cable with M8 connector (3 pins/3 m)
15 PCA-1557730 Fieldwireable connector (M8/3 pins/Plug/Piercecon® connection)
Fieldwire-
For
able
sensor
16 PCA-1557743 Fieldwireable connector
connector
17 PCA-1557756 (M12/4 pins/Plug/QUICKON-ONE connection/SPEEDCON)

For 20 PCA-1557785 Y connector (2 x M12 (3 pins)-M12 (5 pins)/SPEEDCON)


Y connector
sensor 21 PCA-1557798 Y connector (2 x M8 (3 pins)-M12 (4 pins)/SPEEDCON)
Features 2
Other M8/M12 Connector Accessories (EX500/EX250/EX9)

B Power cable with connector P. 9 to P. 12


(For GW unit) C Cable with M12 connector
F Seal cap Output block
A Communication connector (For socket)
Power block

B Power cable with connector


(For EX250/Power block)

E Cable with connector


for output entry

F Seal cap (For socket)

D Terminal plug

F Seal cap (For plug)

A Communication connector B Power cable with connector D Terminal plug (For EX500)
• For AB RIO • For GW unit (A-coded)
• For DeviceNetTM (With cable) • For EX250/Power block (B-coded) E Cable with connector for output entry
• For EtherNet/IPTM F Seal cap
(RJ45-M12, with cable) C Cable with M12 connector (For EX500)
• For plug
• For socket

 Other M8/M12 Connector Accessories (EX500/EX250/EX9)


Description Application No. SMC part no. Name
For Fieldbus EX500-AC-DN Communication cable for DeviceNetTM (Socket)
A
communication EX9-AC020EN-PSRJ Communication cable for EtherNet/IPTM (M12 plug/D-coded-RJ45)
EX500-AC-S
Power cable with connector (Socket/A-coded)
For power supply B EX500-AC-A
Cable with connector
EX9-AC-1 Power cable with connector (Socket/B-coded)
EX500-AC-SSPS Cable with M12 connector (8 pins/Both straight)
For EX500 C
EX500-AC-SAPA Cable with M12 connector (8 pins/Both angle)
For output entry E EX9-AC-7 Cable with M12 connector (Plug/A-coded)
Fieldwireable connector For Fieldbus communication A EX500-AC000-AB Communication connector for Remote I/O (Socket)
Terminal plug For EX500 D EX500-AC000-S Terminal plug (M12/8 pins)
EX500-AWTP Seal cap (M12/For plug)
Seal cap For plug F EX9-AWES Seal cap (M8/For socket)
EX9-AWTS Seal cap (M12/For socket)
Features 3
Communication Cable/Connector
Example of Connection/Specifications
• CC-Link P.1
• DeviceNetTM P.2
• PROFIBUS DP P.3
Dimensions P.4

Between Sensor/Switch and Input Device


Example of Connection P.5
Specifications/Dimensions
• Fieldwireable connector P.6
• Cable with connector P.7
• Y connector P.8

Other Accessories
Example of Connection P.9
How to Order/Dimensions P.10

Assembly Procedure
Spring-cage connection P.13
QUICKON-ONE connection P.14
Piercecon® connection P.15

Compatibility between Sensors and Fieldwireable Connectors P.16


American Wire Gauge Conversion Table P.17
Safety Instructions/Precautions Back page 1
Front matter 1
M12

Communication Cable/Connector
Example of Connection
PLC

3
Serial wiring with
Input/Output unit
Solenoid valve manifold

3
IN side 1
Discrete and
decentralized
serial wiring
GW unit
1 IN side
OUT side 2

2 OUT side
Series EX250

4 Series EX500
Specifications

Description Communication cable (With one side connector) Fieldwireable connector


Fieldwirable connector
Part no. PCA-1567720 PCA-1567717 PCA-1557617 PCA-1557620
1 2 3 4

Product image

Socket Plug Plug Socket


Number of functional poles M12: 4 poles
Key type A-coded (Normal key)
4 3 3 4
1: SLD (Shield wire)
1 2 2 1 2: DB (White)
Pin assignment
3: DG (Yellow)
Plug, A-coded Socket, A-coded 4: DA (Blue)
(Viewed from the plug/socket side)
Fixed cable length 5m —
Wiring specifications Note)

Cable O.D. 7.7 ±0.3 mm Applicable 4.0 to 8.0 mm


Wire gauge (Stranded wire cross section) 0.5 mm2/AWG20 cable 0.14 to 0.5 mm2/AWG26 to 20
Wire outer diameter (Including insulating material) 2.55 ±0.07 mm —
Connection type — Spring-cage connection
Rated current 4A
Rated voltage 250 V 48 V
Contact resistance ≤ 5 mΩ
Rating/Performance

Insulation resistance ≥ 100 MΩ


Withstand voltage 1.4 kV
Ambient Connector –25 to 90°C –40 to 85°C
tempera- Operating –20 to 60°C —
ture Cable
Fixed –20 to 60°C —
Protection class IP67 (Only with screw tightened)
Allowable repeated insertion/withdrawal 200
Cable retaining force 150 N/15 sec. —
Vibration resistance 10 to 500 Hz/98 m/s2
Material of knurl Zinc for die casting Brass
Material

Contact (Surface treatment) CuSn (Au plating (Ni plating))


Insulating material Thermoplastic polyurethane (TPU) Polyamide (PA6.6)
Material of sheath Polyvinyl chloride (PVC) —
Weight (Mass) Approx. 306 g Approx. 308 g Approx. 48 g Approx. 53 g
Note) The shaded parts show the specifications for the applicable cable. Adaptation for the connector may vary on account of the conductor construction of the electric wire.
1
M12

Communication Cable/Connector
Example of Connection

PLC

9
Serial wiring with
Input/Output unit
Solenoid valve manifold Connected at the end
Discrete and decentralized
7 6 7 serial wiring
GW unit

5
8
Series EX250

Series EX500
Specifications

Description Communication cable (With one side connector) Fieldwireable connector Terminal plug
Part no. PCA-1557633 PCA-1557646 PCA-1557659 PCA-1557662 PCA-1557675
5 6 7 8 9

Product image
For DeviceNetTM
Socket Plug Plug Socket (Plug, A-coded)
Number of functional poles M12: 5 poles
Key type A-coded (Normal key)
5 4 3 5 3 4DeviceNetTM / CANopen 1: DRAIN: NC
1: DRAIN 1: — 2: V+: NC
Pin assignment 1 2 2 1 2: V+ (Red) 2: — 3: V–: NC
3: V– (Black) 3: CAN GND
Plug, A-coded Socket, A-coded 4: CAN H
4: CAN H (White) 4: CAN H 121 Ω
(Viewed from the plug/socket side) 5: CAN L (Blue) 5: CAN L 5: CAN L
Fixed cable length 5m —
Wiring specifications Note)

Cable O.D. 6.70 ±0.3 mm 4.0 to 8.0 mm —


Wire gauge Applicable
Power pair 0.33 mm2/AWG22
(Stranded wire cable 0.14 to 0.5 mm2/AWG26 to 20 —
cross section) Data pair 0.2 mm2/AWG24
Wire outer diameter Power pair 1.4 ±0.05 mm
(Including insulating —
material) Data pair 2.05 ±0.10 mm
Connection type — Spring-cage connection —
Rated current 4A —
Rated voltage 48 V
Contact resistance ≤5 mΩ
Rating/Performance

Insulation resistance ≥ 100 MΩ —


Withstand voltage 1.0 kV —
Ambient Connector –25 to 90°C –40 to 85°C –25 to 90°C
tempera- Operating –20 to 75°C —
ture Cable
Fixed –40 to 80°C —
Protection class IP67 (Only with screw tightened)
Allowable repeated insertion/withdrawal 200
Cable retaining force 150 N/15 sec. —
Vibration resistance 10 to 500 Hz/98 m/s2
Material of knurl Zinc for die casting Brass Zinc for die casting
Material

Contact (Surface treatment) CuSn (Au plating (Ni plating))


Insulating material Thermoplastic polyurethane (TPU) Polyamide (PA6.6) Thermoplastic polyurethane (TPU)
Material of sheath Polyurethane (PUR) —
Weight (Mass) Approx. 308 g Approx. 306 g Approx. 47 g Approx. 53 g Approx. 12 g
Note) The shaded parts show the specifications for the applicable cable. Adaptation for the connector may vary on account of the conductor construction of the electric wire.
2
M12

Communication Cable/Connector
Example of Connection
PLC

13 12
A product
connected
at the end

14
Serial wiring with
Input/Output unit
IN side OUT side
Solenoid valve manifold
10 11 10 11

Discrete and
decentralized
serial wiring
GW unit

Series EX250
Series EX500
Specifications

Description Communication cable (With one side connector) Fieldwireable connector Terminal plug
Part no. PCA-1557688 PCA-1557691 PCA-1557701 PCA-1557714 PCA-1557727
10 11 12 13 14

Product image

For PROFIBUS DP
Socket Plug Plug Socket (Plug, B-coded)
Number of functional poles M12: 2 poles M12: 3 poles M12: 4 poles
Key type B-coded (Reverse key)
5 4 3 5 3 4 1: — 1: VP
390 Ω
2: A Line (Green) 4: B Line
Pin assignment 1 2 2 1 3: — 220 Ω

4: B Line (Red) 2: A Line


Plug, B-coded Plug, B-coded 390 Ω
5: — 3: DGND
(Viewed from the plug/socket side)
Fixed cable length 5m —
Wiring specifications Note)

Cable O.D. 7.80 ±0.2 mm Applicable 4.0 to 8.0 mm —


Wire gauge (Stranded wire cross section) 0.34 mm2/AWG22 cable 0.14 to 0.5 mm2/AWG26 to 20 —
Wire outer diameter (Including insulating material) 2.55 ±0.07 mm —
Connection type — Spring-cage connection —
Rated current 4A —
Rated voltage 60 V 48 V 60 V
Contact resistance ≤ 5 mΩ
Rating/Performance

Insulation resistance ≥ 100 MΩ —


Withstand voltage 1.4 kV —
Ambient Connector –25 to 90°C –40 to 85°C –25 to 90°C
tempera- Operating –20 to 80°C —
ture Cable
Fixed –40 to 85°C —
Protection class IP67 (Only with screw tightened)
Allowable repeated insertion/withdrawal 200
Cable retaining force 150 N/15 sec. —
Vibration resistance 10 to 500 Hz/98 m/s2
Material of knurl Zinc for die casting Brass Zinc for die casting
Material

Contact (Surface treatment) CuSn (Au plating (Ni plating))


Insulating material Polyamide (PA6.6) Thermoplastic polyurethane (TPU)
Material of sheath Polyurethane (PUR) —
Weight (Mass) Approx. 343 g Approx. 356 g Approx. 48 g Approx. 54 g Approx. 12 g
Note) The shaded parts show the specifications for the applicable cable. Adaptation for the connector may vary on account of the conductor construction of the electric wire.
3
Communication Cable/Connector

Dimensions

Communication cable (With one side connector)


1 PCA-1567720 44.5 5000 50
For CC-Link 1 2

ø14.8
(Socket)
4 3

ø7.7
Socket connector pin assignment M12
A-coded (Normal key) SPEEDCON

Terminal Cable wire 2 PCA-1567717 47.3 5000 50


no. colors For CC-Link 2 1

ø14.8
2
1
White: DB
: SLD
(Plug)
3 Yellow: DG
4 Blue: DA
3 4

ø7.7
M12
Wiring Plug connector pin assignment
A-coded (Normal key) SPEEDCON

5 PCA-1557633 44.5 5000 50


For DeviceNetTM 5 1 2

ø14.8
(Socket)
4 3

ø6.7
Socket connector pin assignment M12
A-coded (Normal key) SPEEDCON

6 PCA-1557646 47.3 5000 50


Terminal Cable wire
no. colors For DeviceNetTM 5 2 1
ø14.8

2
1
Red: V+
: DRAIN
(Plug)
3 Black: V–
4 White: CAN H
3 4
5 Blue: CAN L

Plug connector pin assignment M12 ø6.7


Wiring A-coded (Normal key) SPEEDCON

10 PCA-1557688 44.5 5000 50


For PROFIBUS DP 5 1 2
ø14.8

(Socket)
4 3
ø7.8

Socket connector pin assignment M12


B-coded (Reverse key) SPEEDCON
Terminal Cable wire
no. colors 11 PCA-1557691 47.3 5000 50
1 :–
2
3
Green: A Line
:– For PROFIBUS DP 5 2 1
ø14.8

4 Red: B Line
5 :– (Plug)
Shield line is connected 3 4
ø7.8

M12
to the knurl. Plug connector pin assignment
B-coded (Reverse key) SPEEDCON
Wiring

Fieldwireable connector Refer to page 13 for details on assembly.

Plug Socket
3 PCA-1557617 7 PCA-1557659 12 PCA-1557701 4 PCA-1557620 8 PCA-1557662 13 PCA-1557714
For CC-Link For DeviceNetTM For PROFIBUS DP For CC-Link For DeviceNetTM For PROFIBUS DP
≈ 60 ≈ 58
ø19

ø17

ø19

ø17

A-coded B-coded M12 SW16 A-coded B-coded M12 SW16


(Normal key) (Reverse key) (Normal key) (Reverse key)

Terminal plug
56.3
9 PCA-1557675
Terminal resistor
ø14.8

for DeviceNetTM
M12 15.8

56.3
14 PCA-1557727
Terminal resistor
ø14.8

for PROFIBUS DP
M12 15.8

4
Between Sensor/Switch and Input Device
Example of Connection
Cable with connector Input block
1 Sensor with pre-wired connector P. 7 Input unit manifold
 Series EX500
Direct connection between connectors

18

M12

Fieldwireable connector P. 6 M12 • EX500-IE3, 4


2 Sensor with lead wire M12
M8
entry For connection,
see
Lead wire → M8/M12 16 18 • EX500-IE1, 2
P. 14
connector conversion • EX500-IE5, 6

“QUICKON-ONE” connection

17
Manifold solenoid valve
with input unit
 Series EX250

M8
connection M8
For connection, 19
see
15 P. 15 M12

Y connector P. 8 • EX250-IE1, 2
3 Auto switch with M12 M12
M8
pre-wired connector
x2 M12
20
• EX250-IE3

18

M8/M12 connector M8 M12


(Fieldwireable/Pre-wired) x2
21
Pre-wired
type
∗ Can be wired to the
input block after converting 1-output
signal to 2-output signal. (M12 only)
Fieldwireable connector P. 6

4 Auto switch with M12


lead wire entry
Lead wire → M8/M12 16
connector conversion
“QUICKON-ONE” connection

17

M8
connection

15
∗ Cut the cable into the necessary length, and wire with fieldwireable connectors.

5
Between Sensor/Switch and Input Device
Fieldwireable Connector

Specifications

Part no. PCA-1557730 PCA-1557743 PCA-1557756


15 M8 16 M12 17 M12
4
4 3 4 3
Product image/Pin assignment
1 3
1 2 1 2
Plug Plug Plug
Number of functional poles M8: 3 poles M12: 4 poles
Key type — A-coded (Normal key)
Cable O.D. 3.0 to 5.0 mm 3.5 to 6.0 mm 4.0 to 8.0 mm
Wiring specifications Note)

Applicable cable

Wire gauge (Stranded 0.14 to 0.25 mm2/AWG26 to 24


0.14 to 0.34 mm2/AWG26 to 22 0.34 to 0.75 mm2/AWG22 to 18
wire cross section) 0.25 to 0.34 mm2/AWG24 to 22
Core wire diameter (Including insulating material) 1.0 to 1.6 mm 0.7 to 1.3 mm 1.3 to 2.5 mm
Connection type Piercecon® connection QUICKON-ONE connection
Rated current 4A
Rated voltage 60 V 250 V
Rating/Performance

Contact resistance ≤ 5 mΩ
Insulation resistance ≥ 100 MΩ
Withstand voltage 1.0 kV 1.4 kV
Ambient temperature –40 to 85°C –25 to 80°C
Protection class IP67 (Only with screw tightened)
Allowable repeated insertion/withdrawal 100 200
Allowable number of repeated connection
between conductors of the same cross section 10
Vibration resistance 10 to 500 Hz/98 m/s2
Material of knurl Brass Zinc for die casting
Material

Contact (Surface treatment) CuZn (Au plating (Ni plating))


Insulating material Polyamide (PA6.6)
Weight (Mass) Approx. 14 g Approx. 13 g Approx. 15 g
Note) The shaded parts show the specifications for the applicable cable. Adaptation for the connector may vary on account of the conductor construction of the electric wire.

Dimensions

15 PCA-1557730
Fieldwireable connector (M8) 35.4
Terminal no. Wire color

1 Brown
3 1
12

3 Blue
4 Black

M8 4
SW11 Wiring
Plug connector
Refer to page 15 for details on assembly. pin assignment
16 PCA-1557743
Fieldwireable connector (M12)
≈ 53
Terminal no. Wire color
2 1
1 Brown
ø14.8

ø16.3

2 White
3 Blue
4 Black
3 4
M12
SPEEDCON Plug connector Wiring
pin assignment
Refer to page 14 for details on assembly.
A-coded (Normal key)
17 PCA-1557756
Fieldwireable connector (M12)
≈ 55 Terminal no. Wire color
2 1
1 Brown
SW15

SW15
ø14.8

ø18.4

2 White
3 Blue
4 Black
3 4
M12
Plug connector Wiring
SPEEDCON
pin assignment
Refer to page 14 for details on assembly. A-coded (Normal key)
6
Between Sensor/Switch and Input Device
Cable with Connector

Specifications

Part no. PCA-1557769 PCA-1557772


18 M12 19 M8

Product image

Number of functional poles M12: 4 poles M8: 3 poles


Key type A-coded (Normal key) —
Fixed cable length 3m
specifications
Wiring

Cable O.D. 4.7 ±0.15 mm 4.4 ±0.15 mm


Wire gauge (Stranded wire cross section) 0.34 mm2/AWG22 0.25 mm2/AWG24
Rated current 4A
Rated voltage 250 V 60 V
Contact resistance ≤5 mΩ
Rating/Performance

Insulation resistance ≥ 100 MΩ


Withstand voltage 1.4 kV 1.0 kV
Ambient Connector –25 to 90°C
tempera- Operating –5 to 80°C
ture Cable
Fixed –40 to 80°C
Protection class IP67 (Only with screw tightened)
Allowable repeated insertion/withdrawal 200
Cable retaining force 150 N/15 sec. 250 N/15 sec.
Vibration resistance 10 to 500 Hz/98 m/s2
Material of knurl Zinc for die casting
Material

Contact (Surface treatment) CuSn (Au plating (Ni plating))


Insulating material Thermoplastic polyurethane (TPU)
Material of sheath Polyurethane Black (PUR Black)
Weight (Mass) Approx. 111 g Approx. 80 g

Dimensions
18 PCA-1557769
Cable with M12 connector (4 poles)

44 3000 46.8
1 2 2 1
1 1
ø14.8

ø14.8

2 2
3 3
4 4
ø4.7

M12 M12 4 3 3 4
SPEEDCON Wiring
SPEEDCON Socket connector Plug connector
pin assignment pin assignment
A-coded (Normal key) A-coded (Normal key)

19 PCA-1557772
Cable with M8 connector (3 poles)

34 3000 38.7
1 1
ø10

ø10

1 3 3 3 3 1
4 4
ø4.4

M8 M8 4 4
Wiring
Socket connector Plug connector
pin assignment pin assignment

7
Between Sensor/Switch and Input Device
Y Connector

Specifications

Part no. PCA-1557785 PCA-1557798


20 M12 21
M8
M12 M12
Product image
M12 M8

Number of functional poles 2 x M12: 4 poles + PE – M12: 4 poles + PE 2 x M8: 3 poles – M12: 4 poles
Key type A-coded (Normal key)
Rated current 4A
Rated voltage 60 V
Rating/Performance

Contact resistance ≤ 5 mΩ
Insulation resistance ≥ 100 MΩ
Withstand voltage 1.0 kV
Ambient temperature –25 to 90°C
Protection class IP67 (Only with screw tightened)
Allowable repeated insertion/withdrawal 200
Vibration resistance 10 to 500 Hz/98 m/s2
Material of knurl Zinc for die casting
Material

Contact (Surface treatment) CuZn (Au plating (Ni plating))


Insulating material Thermoplastic polyurethane (TPU)
Weight (Mass) Approx. 29 g Approx. 13 g

Dimensions
20 PCA-1557785
Y connector
(2 x M12-M12) Socket connector
pin assignment
50.1 A-coded (Normal key)
ø14.8 13 15.8 ø14.8 q 51 2 1
2
3
4
5
4 3 1 5 2 1
2
32.4

32.6
ø15
18

3
4
M12 w 5
5 1 2 1 3 4
SPEEDCON 2
3 Plug connector
ø4

4
.2

M12 17 M12
4 3
5 pin assignment
SPEEDCON SPEEDCON A-coded (Normal key)
Socket connector Wiring
pin assignment
21 PCA-1557798 A-coded (Normal key)
Y connector
(2 x M8-M12)

40.7 Socket connector


pin assignment
ø9.9 8.3 15.8 ø14.8 1
q 1 3 3
4 2 1
4 1
21.8

21.7

2
ø13
12

3
4
M8 1 3 4
w 1 3 3
M8 M12 4 Plug connector
SPEEDCON 4 pin assignment
Socket connector Wiring A-coded (Normal key)
pin assignment

Connection image
8
Other Accessories
M8/M12 Connector Accessories (EX500/EX250/EX9)

B Power cable with connector C Cable with M12 connector


(For GW unit)
Output block
F Seal cap
A Communication connector (For socket)
Power block

B Power cable with connector


(For EX250/Power block)

E Cable with connector


for output entry

F Seal cap (For socket)

D Terminal plug

F Seal cap (For plug)

A Communication connector C Cable with M12 connector (For EX500) E Cable with connector for output entry
• For AB RIO
• For DeviceNetTM (with cable)
• For EtherNet/IPTM
(RJ45-M12, with cable)

B Power cable with connector D Terminal plug (For EX500) F Seal cap
• For GW unit (A-coded) • For plug
• For EX250/Power block (B-coded) • For socket

9
Other Accessories

A Communication connector
M12
For Remote I/O (AB RIO)

ø14.2
2

EX500 AC000 AB
1 3
4

43.2
Applicable cable size

ø14.9
ø6 (ø5 to ø6)

For DeviceNetTM For EtherNet/IPTM

EX500 AC 050 DN EX9 AC 020 EN PSRJ


Cable length (l)
Cable length (l)
020 2000 [mm]
010 1000 [mm]
050 5000 [mm] Connector specification
PSRJ M12 plug (Straight) ⇔ RJ-45 connector
M12
ø7

M12 RJ-45

ø6.7
50
ø14.9

40.7 47.3 l 45
l
Core wire 1

Terminal no. Core wire 2 1 Terminal no. Terminal no. colors 2


3
4
colors 1 1 White
Paired 5
2 2 Orange 6
1 2 1 : DRAIN 3 4 3 3 White 7
5 Red: V+ 4 4 8
2
3 Black: V– Plug connector 5
Paired
6 Green
4 White: CAN H pin arrangement 7 Plug connector
5 Blue: CAN L
4 3
8
pin arrangement
Shield
Socket connector Wiring
pin arrangement Wiring (Straight cable)

B Power cable with connector (For GW unit (A-coded))


EX500 AP 050 S
Cable length (l) Connector specification
010 1000 [mm] S Straight
050 5000 [mm] A Angle

Straight connector type Angle connector type


M12
ø6

M12

18
ø14.9

ø6

34
28.3

30 5
48 50
l
31.3 30 5

Terminal no. Core wire l 50


1 2 colors
5
1 Brown Terminal no. Core wire
2 White 1 2 colors
3 Blue 5
4 3 4 Black 1 Brown
5 Gray 2 White
Socket connector 4 3
3 Blue
4 Black
pin arrangement Wiring 5 Gray
Socket connector
pin arrangement Wiring
10
Other Accessories

M8/M12 Connector Accessories (EX500/EX250/EX9)


B Power cable with connector (For EX250/Power block (B-coded))
l
EX9 AC 050 1 M12
48.1

Cable length (l)


010 1000 [mm]
30 5

ø6.4
030 3000 [mm] Terminal no. Core wire
050 5000 [mm] 1 2 colors 50
5
1 Brown
2 White
3 Blue
4 3 4 Black
5 Gray
Socket connector
pin arrangement Wiring

C Cable with M12 connector


EX500 AC 030 SSPS
Cable length (l) Connector specification
003 300 [mm] SSPS Socket side: Straight, Plug side: Straight
005 500 [mm] SAPA Socket side: Angle, Plug side: Angle
010 1000 [mm]
030 3000 [mm]
050 5000 [mm]

Straight connector type Angle connector type


l
48 52 M12 M12
M12
ø6

ø16

ø6

32.3
28.3

M12
ø14.9

31.3 31.3
Terminal no. Core wire l
colors
8 1 2 1 1 White 8 2 1 Terminal no. Core wire
2 2 Brown
colors
7 3 3 3 Green 3 7
4 4 Yellow 8 1 2 1 1 White 8 2 1
5 5 Gray 2 2 Brown
6 4 6 6 Pink 4 6 7 3 3 3 Green 3 7
7 7 Blue
5 8 8 Shield
5 4 4 Yellow
5 5 Gray
6 4 4 6
Socket connector Plug connector 6
7
6
7
Pink
Blue
Wiring 5 5
pin arrangement pin arrangement 8 8 Shield
Socket connector Plug connector
pin arrangement Wiring pin arrangement

D Terminal plug
This is used where an input unit manifold (input unit/input block) is not being used.
(If a terminal plug is not used, the GW unit’s COM LED will not light up.)

EX500 AC000 S
M12

8 2 1
3 7
ø16

4 6
5
Plug connector
pin arrangement 44.7

11
Other Accessories

E Cable with connector for output entry l

EX9 AC 030 7
52
M12

Cable length (l)


30 5

ø6.4
010 1000 [mm] Terminal no. Core wire
030 3000 [mm] 2 1 colors 50
5
1 Brown
2 White
3 Blue
3 4 4 Black
5 Gray
Plug connector
pin arrangement Wiring

F Seal cap: M12 connector (For plug) F Seal cap: M8, M12 connector
Use this on ports that are not being used for a M12 connector (plug). (For socket)/Accessories
Use of this waterproof cap maintains the integrity of the enclosure.
Use this on ports that are not being used for a M8, M12 connector
Note) Tighten the waterproof cap with the prescribed tightening torque. (For M12: 0.1
N·m)
(socket).
Use of this waterproof cap maintains the integrity of the enclosure.
(Waterproof cap is packed together with each unit.)
EX500 AWTP Note) Tighten the waterproof cap with the prescribed tightening torque. (For M8: 0.05
N· m, For M12: 0.1 N·m)
9.4
EX9 AW
Connector type
ø14.9

ES M8 connector (For socket, 10 pcs.)


TS M12 connector (For socket, 10 pcs.)

11 14 14
10.8

M8 x 1
M12 x 1
6.6 10.2

M8 connector (For socket) M12 connector (For socket)

12
Assembly Procedure
Spring-cage Connection

Corresponding Model Assembly Procedure

 Plug • For CC-Link Slide Cap q and Body q w


3 PCA-1557617 w over the cable.
• For DeviceNetTM
7 PCA-1557659
Strip the cable sheath
• For PROFIBUS DP
over a length of approx.
12 PCA-1557701
28 mm for straight
connector. Trim the
 Socket • For CC-Link braided shield to a length 12
4 PCA-1557620 of approx. 12 mm. 28

• For DeviceNetTM
Fold back the braided
8 PCA-1557662
shield over the cable 10
• For PROFIBUS DP sheath.
13 PCA-1557714 Strip approx.10 mm off
the single wires.
If necessary, crimp
Features suitable ferrules to the
• M12 connector corresponding to shield connecting end of each wire.
• Save wiring time approx. 40% compared to screw and solder
Connect the wire into
connection.
• Color-coded wire connection part allows easy wiring and Body .
prevents miswiring. In case of stranded wire,
• Easy shield treatment press the black button
and open the connection
part and insert the wire.
In case of wire with
ferrule, insert directly The color coding is
without pressing the previously printed on the
connection part according
black button.
to the wire color.
Fold the braided shield
Structure image of wiring Structure image of shield wiring back again. Apply the
attached adhesive shield
foil around the braided
Things to Prepare shield.
• Stripper for cable sheath
(Recommendation: Phoenix Contact KAMES MULTI (1209075))
Pull Body up to Body .
• Stripper for wire sheath
(Recommendation: Phoenix Contact QUICK WIREFOX2.5 (1206667)) Screw Body into Body
• (Small) Nippers for cutting shield .

Product Construction
Check the contents when opening the package. Attach Cap on Body .
Tightening torque:
2.7 to 3.3 N·m

Check if the connector has no loosing by pulling the cable lightly.

Caution
• Do not use it besides an original purpose.
Body Body Gasket Cap • This connector may only be operated when under no load.
Shield foil • The work by the wet hand causes the electric shock.
• Never perform the repair.
13
Assembly Procedure

QUICKON-ONE Connection

Corresponding Model Assembly Procedure

Strip the cable sheath.


(approx. 40 mm)
40
Slide the cable onto
Union nut.
16 PCA-1557743 17 PCA-1557756 Insert the cable sheath
to the stopper inside the
Features Splice ring.

• Quick connection M12 connector with IDC technique


• Save wiring time approx. 80% compared to screw and solder Insert the wires into the
connection. marked core entry of
• The connection is possible by 1/2 turn with SPEEDCON Splice ring.
technique. Splice ring is colored V slit
with respective wire
color of sensor.

Cut off the projecting


wire ends flush by
Structure image of wiring nippers, etc.
Recommended
cutting plane
Things to Prepare
• Stripper for cable sheath
(Recommendation: Phoenix Contact CYCLOPS (1204481))
Meet the mark on
• (Small) Nippers for cutting wire
Body and mark “ ” on
Union nut.
Product Construction Then, combine each
others.
Check the contents when opening the package.

Screw up each others.


Tightening torque:
0.14 to 0.34 mm2 ···
0.72 to 0.88 N·m
0.34 to 0.75 mm2 ···
1.08 to 1.32 N·m
Body Union nut

Finish

Construction of Union nut


Check if the connector has no loosing by pulling the cable lightly.

Caution
• Connection between cables (with the same material and the
Splice ring Seal Cable gland same cross section) is 10 times at max.
• PVC or PE is suitable for sheath material, however fluoro
resin is not suitable for sheath material.
Construction of Cable • Only for flexible cable, not for solid cable.
Max. diameter • When you remove the cable, pull the cable. However, if you
2.6 mm/1.6 mm
remove the Cable gland, cable and the Splice ring remain to
Sheath material:
Wire cross section PVC/PE
the body.
0.34 to 0.75 mm /
2 Sheath diameter • When you connect the cable again, screw the Splice ring
0.14 to 0.34 mm2 4 to 8 mm/3.5 to 6 mm
approx. two turns into the Cable gland before using.
• When you connect the cable again, cut and strip the cable.
• Do not use it besides an original purpose.
Min. core wire diameter • QUICKON-ONE may only be operated when under no load.
0.15 mm (0.1 mm/0.34 mm2)/ • The work by the wet hand causes the electric shock.
0.1 mm
• Never perform the repair.
14
Assembly Procedure

Piercecon® Connection

Corresponding Model Push Pressure hull into Cable


guide.
Meet the position of Pressure hull
(arrow) and Cable guide
(arrow).

15 PCA-1557730

Features Combine and Body .


• Quick connection M8 connector with Piercecon® technique
• Save wiring time approx. 70% compared to screw and solder Meet the position of mark on
connection. Body , Cable guide and Pressure
• Very small construction of a fieldwireable M8 connector hull (arrow).

Screw Cap into Body .


Screw up each others.
Tightening torque: 1.08 to 1.32 N·m
Structure image of wiring

Things to Prepare
• Stripper for cable sheath
(Recommendation: Phoenix Contact CYCLOPS (1204481))
Cut off the projecting wires by
• (Small) Nippers for cutting wire
nippers.

Product Construction
Check the contents when opening the package. Shape the cross sections.

Screw Body into Body .

Meet the position of mark on


Body and Body .
Body Body Cable guide Pressure Cap
hull
Included 2 Cable guides.
White ··· 0.25 to 0.34 mm2 (AWG24 to 22)
Min. wire outer dia. 1.3 mm Tighten without gap between
Black ··· 0.14 to 0.25 mm2 (AWG26 to 24) Body and Body .
Min. wire outer dia. 1.0 mm
Use either one of Cable guides according to the wire. Tightening torque: 1.08 to 1.32 N·m

Assembly Procedure Check if the connector has no


loosing by pulling the cable lightly.
Strip the cable sheath.
(approx. 35 mm)
Finish
35
Slide Cap and Pressure hull
over the cable.

Keep the direction of Pressure Caution


hull (arrow) to the wire side. • Connection between cables (with the same material and the
same cross section) is 10 times at max.
Slide the wire into Cable guide. • Only for flexible cable, not for solid cable.
• When you connect the cable again, cut and strip the cable.
Cable guide is colored with
• Do not use it besides an original purpose.
respective wire color of sensor.
• Piercecon® may only be operated when under no load.
• The work by the wet hand causes the electric shock.
• Never perform the repair.
• Piercecon® is a registered trademark of by CONINVERS GmbH.
15
Compatibility between Sensors
and Fieldwireable Connectors
: Applicable
: Applicable, but number of electric wire cores is limited. (Number of sensor lead wire cores is larger than the number of connector pins.)
Auto Switch : Connectable, but may not correspond to IP65/67 depending on installation method. : Non-conformance
Applicable connector Cable specifications
Cable Number of
Model cores M8 M12 Sheath Insulator Conductor Note
part no.
15 16 17 O.D. Material O.D. Material Nominal cross section Stranding O.D. Material
Integrated Oil resistant Flame-retardant Tin plating annealed
D-P4DW 2 ø6 ø1.9 0.5 mm2 100 pcs./0.08 mm ø0.9 copper bunch
type vinyl semi-rigid PVC stranded wire
D-M9BA Integrated Oil resistant Cross-linked Tin plating copper
2 2.7 x 3.2 ø0.9 0.15 mm2 77 pcs./0.05 mm ø0.5
D-M9BAV type vinyl semi-rigid PVC and silver alloy wire
D-M9NA Tin plating
D-M9PA Integrated Oil resistant Cross-linked copper
3 2.7 x 3.2 ø0.9 0.15 mm2 77 pcs./0.05 mm ø0.5
D-M9NAV type vinyl semi-rigid PVC and silver
D-M9PAV alloy wire
D-M9B Tin plating
D-M9BV Integrated Oil resistant Semi-rigid copper
2 2.7 x 3.2 ø0.9 0.15 mm2 77 pcs./0.05 mm ø0.5
D-M9BW type vinyl PVC and silver
D-M9BWV alloy wire
D-M9N
D-M9P
D-M9NV Tin plating
D-M9PV Integrated Oil resistant Semi-rigid copper
3 2.7 x 3.2 ø0.9 0.15 mm2 77 pcs./0.05 mm ø0.5
D-M9NW type vinyl PVC and silver
D-M9PW alloy wire
D-M9NWV
D-M9PWV

Pressure Switch
Applicable connector Cable specifications
Number of

Cable
cores

Model M8 M12 Sheath Insulator Conductor Note


part no.
15 16 17 O.D. Material O.D. Material Nominal cross section Stranding O.D. Material
Oil resistant Cross-linked 0.20 mm2 Annealed
Z/ISE30- ZS-27-A- 3 ø3.4 ø1.12 40 pcs./0.08 mm ø0.58 UL2130
vinyl PVC (AWG25) copper wire
Oil resistant Cross-linked 0.20 mm2 Annealed
ISE35- ZS-32-A- 3 ø3.4
vinyl
ø1.12
PVC
40 pcs./0.08 mm ø0.58
copper wire
UL2130
(AWG25)
Z/ISE40- Irradiated Tin plating
Integrated Oil resistant 2
Z/ISE50- 5 ø3.5 ø0.97 cross-linked 0.15 mm 30 pcs./0.08 mm ø0.51 annealed
type vinyl (AWG28)
Z/ISE60- PVC copper wire

ZS-31-B Irradiated Tin plating Straight


Oil resistant 2
ISE70/75(H)- 4 ø4.0 ø1.14 cross-linked 0.30 mm 60 pcs./0.08 mm ø0.72 copper
vinyl (AWG23)
ZS-31-C PVC alloy wire Angle

5
Heat-
Integrated Oil resistant 0.15 mm2
Z/ISE80- type
4 ø3.5
vinyl
ø0.95 ±0.10 resistance
(AWG26)
30 pcs./0.08 mm ø0.51 Annealed UL20379
PVC copper wire
3

ISA-8-A Irradiated Tin plating Straight


Oil resistant 2
ISA2- 4 ø6.0 ø1.72 cross-linked 0.53 mm 21 pcs./0.18 mm ø0.9 copper
vinyl (AWG21)
ISA-8-B PVC alloy wire Angle

Flow Switch
Applicable connector Cable specifications
Number of

Cable
cores

Model M8 M12 Sheath Insulator Conductor Note


part no.
15 16 17 O.D. Material O.D. Material Nominal cross section Stranding O.D. Material

ZS-37-A Irradiated Tin plating Straight


PF2A7 Oil resistant
4 ø4.0 ø1.14 cross-linked AWG23 60 pcs./0.08 mm ø0.72 copper
PF2W7 vinyl
PVC alloy wire Angle
ZS-37-B

Oil resistant Cross-linked Annealed


PFM7 ZS-33-D 4 ø3.5
vinyl
ø1.00
PVC
AWG26 28 pcs./0.08 mm ø0.50
copper wire
Note) Information on cable specifications is based on specification sheets supplied by the manufacturer.

16
American Wire Gauge
Conversion Table
This table shows to change American wire gauge (AWG) into a diameter.
The wire material is indicated as AWG (American wire gauge) in the documentations overseas.
Use the following table for conversion into diameter.
Wire size Diameter Cross section Wire size Diameter Cross section Wire size Diameter Cross section
(AWG) (mm) (mm2) (AWG) (mm) (mm2) (AWG) (mm) (mm2)
1 7.348 42.3846 17 1.151 1.0400 33 0.18 0.0254
2 6.543 33.6065 18 1.024 0.8231 34 0.16 0.0201
3 5.827 26.6538 19 0.912 0.6529 35 0.142 0.0158
4 5.189 21.1367 20 0.813 0.5189 36 0.127 0.0127
5 4.62 16.7554 21 0.724 0.4115 37 0.114 0.0102
6 4.115 13.2926 22 0.643 0.3246 38 0.102 0.0082
7 3.665 10.5443 23 0.574 0.2586 39 0.089 0.0062
8 3.264 8.3632 24 0.511 0.2050 40 0.079 0.0049
9 2.906 6.6292 25 0.455 0.1625 41 0.071 0.0040
10 2.588 5.2577 26 0.404 0.1281 42 0.064 0.0032
11 2.304 4.1671 27 0.361 0.1023 43 0.056 0.0025
12 2.052 3.3054 28 0.32 0.0804 44 0.051 0.0020
13 1.829 2.6260 29 0.287 0.0647 45 0.045 0.0016
14 1.628 2.0806 30 0.254 0.0506 46 0.04 0.0013
15 1.45 1.6505 31 0.226 0.0401
16 1.29 1.3063 32 0.203 0.0323

17
Safety Instructions
These safety instructions are intended to prevent hazardous situations and/or equipment damage.
These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or
“Danger.” They are all important notes for safety and must be followed in addition to International
Standards (ISO/IEC), Japan Industrial Standards (JIS)∗1) and other safety regulations∗2).
∗ 1) ISO 4414: Pneumatic fluid power – General rules relating to systems.
ISO 4413: Hydraulic fluid power – General rules relating to systems.
IEC 60204-1: Safety of machinery – Electrical equipment of machines. (Part 1: General requirements)
ISO 10218-1992: Manipulating industrial robots -Safety.
JIS B 8370: General rules for pneumatic equipment.
JIS B 8361: General rules for hydraulic equipment.
JIS B 9960-1: Safety of machinery – Electrical equipment of machines. (Part 1: General requirements)
JIS B 8433-1993: Manipulating industrial robots - Safety.
etc.
∗ 2) Labor Safety and Sanitation Law, etc.

Caution: Operator error could result in injury or equipment damage.


Warning: Operator error could result in serious injury or loss of life.
Danger : In extreme conditions, there is a possibility of serious injury or loss of life.

Warning
1. The compatibility of the product is the responsibility of the person who designs the equipment
or decides its specifications.
Since the product specified here is used under various operating conditions, its compatibility with specific equipment must be
decided by the person who designs the equipment or decides its specifications based on necessary analysis and test results.
The expected performance and safety assurance of the equipment will be the responsibility of the person who has determined
its compatibility with the product. This person should also continuously review all specifications of the product referring to its
latest catalog information, with a view to giving due consideration to any possibility of equipment failure when configuring the
equipment.
2. Only personnel with appropriate training should operate machinery and equipment.
The product specified here may become unsafe if handled incorrectly. The assembly, operation and maintenance of machines or
equipment including our products must be performed by an operator who is appropriately trained and experienced.
3. Do not service or attempt to remove product and machinery/equipment until safety is confirmed.
1. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or
runaway of the driven objects have been confirmed.
2. When the product is to be removed, confirm that the safety measures as mentioned above are implemented and the power
from any appropriate source is cut, and read and understand the specific product precautions of all relevant products
carefully.
3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction.
4. Contact SMC beforehand and take special consideration of safety measures if the product is to
be used in any of the following conditions.
1. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to direct sunlight.
2. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping, vehicles, military,
medical treatment, combustion and recreation, or equipment in contact with food and beverages, emergency stop circuits,
clutch and brake circuits in press applications, safety equipment or other applications unsuitable for the standard
specifications described in the product catalog.
3. An application which could have negative effects on people, property, or animals requiring special safety analysis.
4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical pro tective
function, and periodical checks to confirm proper operation.

Back page 1
Safety Instructions
Caution
The product is provided for use in manufacturing industries.
The product herein described is basically provided for peaceful use in manufacturing industries.
If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract
if necessary. If anything is unclear, contact your nearest sales branch.

Limited Warranty and Disclaimer/Compliance Requirements


The product used is subject to the following “Limited Warranty and Disclaimer” and “Compliance
Requirements”. Read and accept them before using the product.

Limited Warranty and Disclaimer


1. The warranty period of the product is 1 year in service or 1.5 years after the product is deliv-
ered.∗3)
Also, the product may have specified durability, running distance or replacement parts. Please
consult your nearest sales branch.
2. For any failure or damage reported within the warranty period which is clearly our responsibility,
a replacement product or necessary parts will be provided.
This limited warranty applies only to our product independently, and not to any other damage
incurred due to the failure of the product.
3. Prior to using SMC products, please read and understand the warranty terms and disclaimers
noted in the specified catalog for the particular products.
∗ 3) Vacuum pads are excluded from this 1 year warranty.
A vacuum pad is a consumable part, so it is warranted for a year after it is delivered.
Also, even within the warranty period, the wear of a product due to the use of the vacuum pad or failure due to the
deterioration of rubber material are not covered by the limited warranty.

Compliance Requirements
When the product is exported, strictly follow the laws required by the Ministry of Economy, Trade
and Industry (Foreign Exchange and Foreign Trade Control Law).

Back page 2
Cable/Connector Accessories
Precautions
Be sure to read this before handling.

Wiring Handling of Fieldwireable Connector

Caution Caution
1. Do not lay the wires while they are energized. It may Common Precautions
give you an electric shock. 1. Follow “Assembly Procedure” provided by SMC. If
2. It should be cabled according to the connection diagram. not, it may not maintain IP65/67.
3. Check if it can be connected when using a sensor 2. Do not use it besides an original purpose.
or switch. 3. This connector may only be operated when under
4. When the cable sheath is stripped, confirm the no load.
stripping direction. 4. The work by the wet hand causes the electric shock.
(For SMC switches with oblong cables)
5. Never perform the repair.
The insulator may be split or damaged depending on the
direction. Spring-cage Connection
1. Do not use it besides an original purpose.
2. This connector may only be operated when under
no load.
3. The work by the wet hand causes the electric shock.
4. Never perform the repair.
Tightening of Screw
QUICKON-ONE Connection

Caution 1. Connection between cables (with the same material and


the same cross section) is 10 times at max.
1. It cannot maintain the enclosure (IP6) or the 2. PVC or PE is suitable for sheath material, however
screws may be loosened if they are not tightened fluoro resin is not suitable for sheath material.
sufficiently.
3. Only for flexible cable, not for solid cable.
2. Check that they are tightened enough at appropriate
intervals during the operation. 4. When you remove the cable, pull the cable. How-
ever, if you remove the Cable gland, cable and the
Connection and Disconnection of Connector Splice ring remain to the body.
When you connect the cable again, screw the Splice ring ap-
prox. two turns into the Cable gland before using.
Caution 5. When you connect the cable again, cut and strip the
1. Be sure to turn the power off when connecting and cable.
disconnecting the connectors.
Piercecon® Connection
2. Do not touch surface of the engagement with wet hands.
1. Connection between cables (with the same material and
3. Do not pull the cable out by holding the cable.
the same cross section) is 10 times at max.
4. Note the key direction.
2. Only for flexible cable, not for solid cable.
Especially for the SPEEDCON specifications, match the pro-
trusion of the knurl (bracket) and the mark at the mold for in- 3. If you connect the cable again, cut and strip the
sertion so that the SPEEDCON function can be maintained. cable.
5. When engaging the connectors, insert the connectors
enough until all the engagement surfaces can be hidden Operating Environment
and tighten the screws not to damage the thread ridges.

Handling of Cable with Connector


Caution
1. Do not use in the atmosphere and environment over
Caution the rated specifications.
2. Do not use in the environment of corrosive gas or
1. Avoid repeatedly bending or stretching the cable liquid splash.
and applying a heavy object or force to it.
3. Do not use in an environment where oil and chemi-
2. Set up the cables to the place where they cannot be cals are used.
stepped on in order to prevent them being broken
or damage to the connectors.
Install a protective cover in case it is used in the place stated Maintenance
above.
3. Do not pull the connector or cable unnecessarily. It Caution
may damage the connectors or break the cables. 1. Perform periodic inspection.
4. Do not bend the cable at the root of the connector
when installed.
Back page 3
Record of changes
B edition ∗ Correction of “Specifications” due to clerical errors. MX

Akihabara UDX 15F,


4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN
Phone: 03-5207-8249 Fax: 03-5298-5362
URL http://www.smcworld.com
© 2008 SMC Corporation All Rights Reserved
Specifications are subject to change without prior notice D-DN 1st printing MX printing MX 16400DN Printed in Japan.
and any obligation on the part of the manufacturer. This catalog is printed on recycled paper with concern for the global environment.

Você também pode gostar