1 Introduction ToF Tool
1 Introduction
1.1 Installation
Before you install ToF Tool, you must fulfill a number of requirements. For more details,
refer to the Installation Instructions which is located on CD-ROM 1.
On CD-ROM 2:
• Device Description Files (DDs)
• Instrument documentation
Visual cues
Below is a short list of the visual cues used in this manual.
"bold in Keys, buttons, program icons, tabs, "Start -> Programs -> ToF" or
inverted commas" menus, commands. "Enter"
Hold down CTRL (CONTROL) and press Hold down CTRL and press SHIFT.
SHIFT.
Hold down CTRL and click the left mouse Hold down CTRL and click the left
button. mouse button.
4 Endress+Hauser
ToF Tool 1 Introduction
Symbols
The manual uses the following graphic symbols:
Symbols Meaning
#
Caution!
A warning highlights actions or procedures which, if not performed correctly, will
lead to personal injury, a safety hazard or destruction of the device.
"
Note!
Caution highlights actions or procedures which, if not performed correctly, may
lead to personal injury or incorrect functioning of the device.
Endress+Hauser 5
2 Starting the Program ToF Tool
# Caution!
Remember that before an Exit you should save the Device List and Envelope Curve,
unless you are sure you no longer require these data.
6 Endress+Hauser
ToF Tool 3 User interface
3 User interface
If you set up the connection to a device or open an existing Device List, the ToF Tool
screen will look like this:
• Title bar
• Menu bar
• Toolbar
• Parametrisation Editor
• Device List
• Status Bar
• and a separate Help window which opens after you start the Help function.
Endress+Hauser 7
3 User interface ToF Tool
3.2 Toolbar
The toolbar contains separate icons or icon groups e.g. toolbars for editing envelope
curves.
8 Endress+Hauser
ToF Tool 4 Menu bar
4 Menu bar
Besides the standard Windows functions, the menu bar comprises additional functions
for parameters, linearisation table and envelope curves.
The subsections below contain a detailed description of each menu.
The dialog box for "New Device List..." opens automatically when you start ToF Tools.
The dialog box offers four access points:
• Point to point
• Scan Bus
• Open Device List
• Show Demo Devices
Endress+Hauser 9
4 Menu bar ToF Tool
Point to point
With a point to point connection, the selected bus is scanned and a connection is set
up to the first device found.
Scan Bus
Scan the selected bus or all buses to regenerate the Device List. Select the bus you
want to scan from the Device List dialog box and click the button. In the "Scan Bus" dia-
log box, you can change the selected bus if necessary and restrict the range of the
device address. Click the button to scan the bus. The scan process starts automatically.
After scanning, the dialog box displays the results of the scan process. The devices
found on the bus are adopted automatically in the Device List. You can start several
scan processes in succession from the dialog box.
" Note!
You can also set up the connection later. Proceed as follows:
• Click "File" and then "New Device List...". The dialog box for "New Device List..."
opens.
10 Endress+Hauser
ToF Tool 4 Menu bar
" Note!
You can only execute this function in Envelope Curve mode. It permits you to select and
open stored Envelope Curves.
The Parametrisation Editor opens with the Envelope Curve window. The Envelope Curve
window displays the first Envelope Curve set saved.
" Note!
When you load Envelope Curves, the program checks whether the device data (device
type, version) in the diagram window match the data in the file. If there is no match, a
warning is displayed (OK, Cancel). After clicking "OK", you can load the Envelope
Curves data.
In Online mode, you may overwrite the Envelope Curve if you activated "Read Curve"
at the same time. To avoid this, activate "Overlapped Curve" in the "Envelope" menu.
Endress+Hauser 11
4 Menu bar ToF Tool
" Note!
You can only execute this function in Envelope Curve mode. This lets you save an Enve-
lope Curve file.
" Note!
The envelope curves displayed in the diagram window can be saved to a file.
" Note!
If this filename already exists, a message appears and you are asked whether you want
to overwrite the file. After confirming the message, the existing file is overwritten and the
data is irretrievably lost. If you want to append data to an existing file, click the "Yes"
button to add data.
4.1.8 Close
This function closes the Parametrisation Editor.
12 Endress+Hauser
ToF Tool 4 Menu bar
# Caution!
Before starting the print process, make sure the data are updated.
Endress+Hauser 13
4 Menu bar ToF Tool
14 Endress+Hauser
ToF Tool 4 Menu bar
This function saves the active Device List data in PDF format:
# Caution!
Before starting the print process, make sure the data are updated.
Endress+Hauser 15
4 Menu bar ToF Tool
4.1.15 Exit
This function terminates the ToF Tool program.
# Caution!
Remember that before an Exit, you should save the Device List and Envelope Curves,
unless you are sure you no longer require these data.
4.3.3 Toolbar
You can activate or deactivate the toolbar with this function (see »Toolbar« on Page 8).
16 Endress+Hauser
ToF Tool 4 Menu bar
Endress+Hauser 17
4 Menu bar ToF Tool
4.4.4 Connect
This function sets up a connection to the device.
4.4.5 Disconnect
This function disconnects the device.
18 Endress+Hauser
ToF Tool 4 Menu bar
4.4.8 Upload
Load all the setting parameters and envelope curves from the device and save them to
the ToF Tool using this function.
4.4.9 Download
The parameters saved in the ToF Tool can be loaded into the device either fully or partly.
Endress+Hauser 19
4 Menu bar ToF Tool
How to download the setting parameters from the ToF Tool to the device:
• In the Device List, select the device to which you want to load the setting data.
• Click "Download" in the "Device" menu or click the device with the right mouse button.
This opens a shortcut menu. Select the "Download" option.
• Enter the folder and the filename in the "Download" dialog.
• Activate the "Selective Download" check box if you only want to execute a partial
download.
• For a partial download, select the download group from the "Section" list. This is the
group you want to transmit to the device.
• Click the "Download" button, to start transmission.
" Note!
The download groups shown in the list are defined in the Device Description and are
therefore dependent on the device and the device description. Only one download
group can be selected at a time for a download.
4.4.10 Properties...
This function displays the device properties (such as device type, version, bus, address
and serial number).
20 Endress+Hauser
ToF Tool 4 Menu bar
4.5.1 Settings...
Endress+Hauser 21
4 Menu bar ToF Tool
22 Endress+Hauser
ToF Tool 4 Menu bar
" Note!
All languages selected during the installation are displayed in the "Language" combo
box. If one of the possible ToF Tool languages is missing from the combo box, it can also
be installed (refer to Installation Instructions of ToF Tool).
Logging
You can set up a log file in the "Logging" combo box.
Endress+Hauser 23
4 Menu bar ToF Tool
Directories
You can set up the paths of the ToF Tool files in the "Directories" combo box.
24 Endress+Hauser
ToF Tool 4 Menu bar
Endress+Hauser 25
4 Menu bar ToF Tool
ToF Tool
-
+
Order information: The analog HART modem (Type: HMA02) can be ordered from
Friesia under the following email address: friesia@t-online.com
26 Endress+Hauser
ToF Tool 4 Menu bar
4.5.5 Dial Up
You can dial up the set up modem connection by this function.
Endress+Hauser 27
4 Menu bar ToF Tool
" Note!
When the Table window is active, the "Table" menu is part of the main menu in the menu
bar.
You can create, edit, import and export a linearisation table using this menu.
28 Endress+Hauser
ToF Tool 4 Menu bar
4.7.6 Export
You can save a linearisation table from the table editor to a file (type *.csv) using this
function.
4.7.7 Import
You can load a linearisation table from a file (type *.csv) to the table editor using this
function.
# Caution!
After importing the table is not yet present in the instrument. Use the "Write" button in the
"Linearisation table" dialog window, to write the function from the table editor to the
instrument (see Page 52).
Endress+Hauser 29
4 Menu bar ToF Tool
" Note!
The QH program can also be started directly from the "QH" button in the toolbar.
" Note!
The QH program can only be started, if Excel (Version 97 or higher) is installed on your
computer.
" Note!
The QH program contains Excel macros. Therefore, on starting up a warning message
is displayed which has to be confirmed by "Yes".
30 Endress+Hauser
ToF Tool 4 Menu bar
Selecting a language
1. Press the "Select language" button on the right next to the form.
2. Select the desired language version.
3. Confirm your selection and exit the input window by pressing "OK".
The form and the operating buttons appear in the selected language.
3. Confirm your entry and exit the input window by pressing "OK".
The data entered are transferred to the header field on the form.
Selecting an application
1. Press the "New application" button on the right next to the form.
2. Select the desired application.
Endress+Hauser 31
4 Menu bar ToF Tool
Changing an application
1. Press the "Change application" button on the right next to the form.
2. Enter the application specific parameters of your weir or flume.
Saving a table
1. Press the "Save table" button on the right next to the form.
2. Select the instrument for which you want to use the QH curve:
– Prosonic T: 11 points
– Prosonic / Prosonic M: 32 points
3. Confirm your selction by pressing "OK". The Windows input window "Save as" the
opens automatically.
4. Save the table to your target directory.
32 Endress+Hauser
ToF Tool 4 Menu bar
" Note!
When the Envelope Curve window is active, the "Envelope Curve" menu is part of the
main menu in the menu bar.
The "Envelope Curve" menu consists of the following functions and submenus (in bold
face):
• Read Curve
• Cyclic Read
• Read MAP
• End Read
• Read Settings...
• Cyclic Read Settings...
• Reset Reading Range
• Edit Parameter List
• Overlapped Curve
• "Play Back" submenu
– Selected Curves...
– Forward
– Fast Forward
– Reverse
– Fast Reverse
– Stop
– Pause
• "Display" submenu
– Clear Plot Display
– Zoom and Grid Settings...
– Reset Zoom Area
– Undo Zoom
– First Envelope Curve
– Last Envelope Curve
– Next Envelope Curve
– Previous Envelope Curve
• Extract...
• Export To File...
• Import Curve from upload file...
• Export Curve to upload file...
• Remarks...
• Load Ideal Echo Curve...
• Move Ideal Echo Curve To Peak
• "Set Cursor" submenu
– Cursor 1
– Cursor 2
– Edit Curve under Cursor (Ctrl+E)
– Free
– Envelope Curve
– MAP
– FAC
• "Layout" submenu
– All
– Diagram
– Diagram+Parameters
– Diagram+Info
– Parameters
– Parameters+Info
Endress+Hauser 33
4 Menu bar ToF Tool
You can change the read options for the envelope curve with this function.
The values in the displayed area define the segment of the envelope curve and the
appearance of the X axis in the diagram window.
The position of the slide bar determines the number of read data points. The position of
the slide bar has the following effect:
High = 100% means that the maximum number of data points is read. The number is
defined by the device and the corresponding device description.
Medium = 50% means that 10% of the maximum number of data points are read.
Low = 0% means that 1% of the maximum number of data points are read.
34 Endress+Hauser
ToF Tool 4 Menu bar
You can change the read options for cyclic reading envelope curves with this function.
How to change the envelope curve read parameters for Cyclic Read:
• Use the "Cyclic Read Settings..." dialog box to define the cycle time, events and the
operations used for cyclic reading and saving the envelope curve. The options you
set are effective for the current version of ToF Tools.
• Click "Cyclic Read Settings..." in the Envelope Curve menu or the button in the tool-
bar to change the settings.
You can set the following settings and events in the "Cyclic Read Settings" dialog box:
• Time
Enter the time between envelope curve updates in seconds.
• Conditional Time
You can only make an entry in this row if the "Evaluate Condition" check box is acti-
vated. The cycle time entered here is only valid if the dependencies entered in "Con-
ditions" are true. The "Conditional Time" replaces the above-mentioned time.
Endress+Hauser 35
4 Menu bar ToF Tool
How to cascade the envelope curves displayed in the Diagram dialog box:
The envelope curves shown in the Diagram dialog box are deleted when a new
envelope curve is read. If you want to insert a new envelope curve in the Diagram dialog
box without deleting the one currently on display, proceed as follows:
• In the "Envelope Curve" menu, activate the "Overlapped Curve" option (this is indi-
cated by a check mark).
• Click "Read Curve" in the "Envelope Curve" menu. The new envelope curve is dis-
played in the same Diagram window as the previously read envelope curve. By
repeating this process several times, you can display several envelope curves cas-
caded in a Diagram window.
36 Endress+Hauser
ToF Tool 4 Menu bar
Using this function you can open a dialog which offers a number of criteria for use with
saved envelope curves to display a subgroup of envelope curve sets.
• according to numbers
• according to date and time
• according to parameter value
" Note!
Filter operations are applied to saved envelope curve sets. When envelope curves are
transmitted (individual or cyclic), no filter operations can be carried out.
Endress+Hauser 37
4 Menu bar ToF Tool
According to numbers
For the "according to numbers" filter criterion, you can enter numbers from the saved
envelope curve sets as the argument. When doing so, remember to enter the numbers
in ascending order.
4.9.2 Forward
This function displays the selected curves in forward direction.
4.9.4 Reverse
This function displays the selected curves in backward direction.
4.9.6 Stop
This function stops the play back. In order to start a new play back click on "Play Back"
again.
4.9.7 Pause
This function interrupts the play back. In order to resume the play back in the selected
direction, click on "Pause" again.
38 Endress+Hauser
ToF Tool 4 Menu bar
How to delete the envelope curves shown in the Diagram dialog box:
• In the "Envelope" menu, click "Clear Plot Display". This deletes the envelope curves
displayed in the Diagram dialog box:
" Note!
Only the envelope curves displayed in the Diagram dialog box are deleted. This
command has no influence on previously saved envelope curves.
Endress+Hauser 39
4 Menu bar ToF Tool
4.10.9 Extract...
This function opens a dialog box which offers a number of criteria for use with saved
envelope curves, to sort envelope curve sets.
• according to number
• according to date and time
• according to parameter value
" Note!
Filter operations are applied to saved envelope curve sets. During transmission (indi-
vidual or cyclic) of envelope curves, no filter operations can be carried out.
According to number
For the "according to number" filter criterion, you can enter numbers from the saved
envelope curve sets as the argument. When doing so, remember to enter the numbers
in ascending order.
40 Endress+Hauser
ToF Tool 4 Menu bar
" Note!
You can not edit the map directly in the device. Uploading the device parameters and
importing the map from the upload file is alway necessary.
Endress+Hauser 41
4 Menu bar ToF Tool
4.10.13 Remarks...
This function allows you to add a remark to an envelope curve files and save it with the
curve set.
42 Endress+Hauser
ToF Tool 4 Menu bar
4.11.1 Cursor 1
You can position cursor 1 within the document window by this function.
4.11.2 Cursor 2
You can position cursor 2 within the document window by this function.
" Note!
You can not edit the mapping curve directly in the instrument. Only maps which have
been imported from an upload file (by the "Import Curve from Upload file" function) can
be edited. When you have completed the editing procedure, use the "Export Curve to
Upload file" function, to write the changes to the upload file. The new map becomes
valid, when you download this file to an instrument (Download).
4.11.4 Free
If you activate this function, the two cursors can be placed freely in the diagram window.
4.11.6 MAP
If you activate this function, the two cursors always stick to the mapping curve.
4.11.7 FAC
If you activate this function, the two cursors always stick to the FAC.
General Information
The envelope curves displayed in the Diagram window can be measured using two
cursors. The cursor can be positioned using either the mouse or the keyboard.
Endress+Hauser 43
4 Menu bar ToF Tool
4.12.1 All
With this function, all informations are displayed in the Envelope dialog window.
4.12.2 Diagram
With this function, only the diagram window is displayed in the Envelope dialog window.
4.12.3 Diagram+Parameters
With this function, the diagram window and the parameters are displayed in the
Envelope dialog window.
4.12.4 Diagram+Info
With this function, the diagram window and the envelope curve information are
displayed in the Envelpe dialog window.
4.12.5 Parameters
With this function, only the parameters are displayed in the Envelope dialog window.
4.12.6 Parameters+Info
With this function, the parameters and the envelope curve information are displayed in
the Envelope dialog window.
44 Endress+Hauser
ToF Tool 4 Menu bar
4.13.1 Cascade
This function allows you to cascade several windows.
4.13.2 Tile
This function allows you to display several windows as tiles.
Endress+Hauser 45
5 Parametrisation Editor ToF Tool
5 Parametrisation Editor
46 Endress+Hauser
ToF Tool 5 Parametrisation Editor
The Navigation Bar is automatically generated from the device description and there-
fore is dependent on the device and the device description. It is divided into groups to
make information management and parameterisation easier.
In Online mode, the value in brackets next to the parameter name indicates the current
value taken from the device. Parameters changed in a parametrisation screen are high-
lighted by an icon until they are updated.
How to change the size of the parameter icons in the Navigation Bar:
• Click the right mouse button on the Navigation Bar background, and then click
"Small Icons" in the shortcut menu to make the parameter icons smaller.
• Click the right mouse button on the Navigation Bar background, and then click
"Large Icons" in the shortcut menu to make the parameter icons larger.
Endress+Hauser 47
5 Parametrisation Editor ToF Tool
48 Endress+Hauser
ToF Tool 5 Parametrisation Editor
5.2.1 Header
Endress+Hauser 49
5 Parametrisation Editor ToF Tool
The Input Window contains the parametrisation screen. This in turn consists of a graphic
(if available) and input fields for the parameters. The structure of the parametrisation
screen is dependent on:
• the selected parameter group
• the device
• the device description
" Note!
Double-click the mouse on a parameter name to open the Help pages of the relevant
Operating Instructions. Click the mouse on the graphic to open the associated Help
pages.
50 Endress+Hauser
ToF Tool 5 Parametrisation Editor
5.2.3 Footer
The following items are displayed in the left-hand section of the footer:
• The parametrisation group name
• The parametrisation group number
• The number of parametrisation screens belonging to a parameter group
.
The Help icon is located in the right-hand section of the status bar. Click the Help icon
to open the Help file for the parametrisation screen.
" Note!
Click the Help icon in the footer to open the Help pages in the appropriate Operating
Instructions.
Endress+Hauser 51
5 Parametrisation Editor ToF Tool
52 Endress+Hauser
ToF Tool 5 Parametrisation Editor
Endress+Hauser 53
5 Parametrisation Editor ToF Tool
How to open the Envelope Curve dialog window in Offline mode (e.g. to load a
saved envelope curve):
• Click "Open" in the "File" menu.
• In the "Open" dialog box, select the directory containing the Envelope Curve File from
the "Search in" shortcut menu, enter the name of an existing envelope curve file in the
filename box.
• Click "OK".
The Parametrisation Editor opens with the Envelope Curve dialog window. The Envelope
Curve window displays the first curve set saved.
54 Endress+Hauser
ToF Tool 5 Parametrisation Editor
Envelope Curves Toolbar Diagram window Envelope Curve List Parameter List
Device data:
Data at Cursor Position Remarks e.g. State of the device Envelope Curves
(current error message) data
Icon Meaning
"Previous" button goes to previous Envelope Curve File. Only active if the previous record
exists.
"Next" button goes to next Envelope Curve File. Only active if the next record exists.
Endress+Hauser 55
5 Parametrisation Editor ToF Tool
Icon Meaning
"Read" button requests the next Envelope Curve File from the Online Device.
"Cancel Read" cancels transfer of the Envelope Curve. Data already transferred are dis-
carded.
"Read Settings" button opens a dialog box to edit read options for an
Envelope Curve.
"Cyclic Read" button executes a cyclical request for the next Envelope Curve File at
predefined intervals.
"Cyclic Read Settings" button opens a dialog box for making settings for Cyclic Read.
"Reset Zoom" button resets the zoom area to the standard settings.
"Reset Reading" button resets the reading range to the standard settings.
"Play-Back Fast Reverse" jumps backwards to the first of the recorded curves.
"Play-Back Reverse" button displays the recorded envelope curves in reverse order.
"Stop Play-Back" button terminates the play-back. In order to display the recorded curves
again click on "Play-Back".
"Pause Play-Back" interrupts the play-back. In order to continue the display in the selected
direction, click on the button again.
"Play-Back Fast Forward" button jumps forward to the last of the recorded envelope curves.
56 Endress+Hauser
ToF Tool 5 Parametrisation Editor
Diagram window
The envelope curves are displayed in the Diagram window. The scales are on the left-
hand side and at the bottom. The minimum and maximum scale values are determined
in the device description and are therefore dependent on the device and the device
description. In a drawn envelope curve, the following values are displayed:
• Empty calibr.
• Full calibr.
The envelope curves can be measured using the cursors. The values at the cursor
position are shown in the Data At Cursor Position window. Displayed envelope curves
can be shown or hidden. You can also overlap several Envelope Curve Sets.
# Caution!
At the next Read request, the deactivated envelope curves are no longer read!
Activate the check box of the envelope curves you want to read and display. Deactivate
the check box of the envelope curves which you do not want to either display or read.
Device data
Saved device data are displayed in this dialog window:
• Device name:
• Tag name:
• Status:
• Serial Number:
" Note!
This window is for information purposes only.
Endress+Hauser 57
5 Parametrisation Editor ToF Tool
Curve Data
The following information is displayed in this dialog window:
" Note!
This dialog window is for information purposes only.
Remarks...
Remarks can be added to envelope curve files and saved with the envelope curves.
The remarks are displayed automatically when you load an envelope curve which was
saved with remarks.
58 Endress+Hauser
ToF Tool 6 Device List
6 Device List
The Device List is located at the bottom of the ToF Tool main window. The Device List
offer you two views for the devices in the form of register cars.
Endress+Hauser 59
6 Device List ToF Tool
Icon Meaning
Demo Device.
60 Endress+Hauser
ToF Tool 6 Device List
The status of the TAGs (measuring point TAG) in displayed by icons in the Device
List:
Icon Meaning
Endress+Hauser 61
7 Status Bar ToF Tool
7 Status Bar
The Status Bar is located at the bottom of the ToF Tool main window.
On the left-hand side, there are descriptions of the highlighted or activated menu
options as well as toolbar buttons. In the centre is a progress bar, depending on the
function executed. Next to the progress bar is a Cancel button. Click this to cancel the
current action.
62 Endress+Hauser
ToF Tool 8 Navigating ToF Tool
You can navigate ToF Tool using the mouse or key combinations. Some views in ToF Tool
have special key combinations which only function in this particular view. Some key
combinations and mouse functions work in all views.
" Note!
The key combinations listed for the Help topics, menus and dialog boxes assume you
have a German keyboard layout. Note that keyboard layouts for other languages may
not be the same as for German. If the keyboard language layout differs from the
languages installed for ToF Tool, the keyboard combinations listed below may not work.
,
£ ¢
UP or
DOWN key
Highlights a device in the Device
List
,
£ ¢
UP or
DOWN key
Highlights a position in the
Device Tree
, ,
£ ¢ «
the Options in the menu; ENTER
key to select the required option
shortcut menu;
toggles between the options in the
menu
Endress+Hauser 63
8 Navigating ToF Tool ToF Tool
F1 key Help
64 Endress+Hauser
ToF Tool 8 Navigating ToF Tool
F1 key Help
,
§¤ §¥
CTRL+RIGHT key or
CTRL+LEFT key
Toggles between cursors
¥,¤
LEFT key or Positions the active cursor
RIGHT key
£,¢
UP key or Positions a free cursor on an Enve-
DOWN key lope Curve
§£,§¢
CTRL+UP key or Changes the assignment of a cur-
CTRL+DOWN key sor to the Envelope Curve
© , ¨ +©
TAB key or Switches to the next group in the
SHIFT+TAB key Envelope Curve window
¢,£
DOWN key or Toggles between options of the
UP key Envelope Curve List
CTRL+P Print
§ +p
Endress+Hauser 65
8 Navigating ToF Tool ToF Tool
,
© ¨ +© , TAB or
SHIFT+TAB or
RIGHT key or
Activates the next or previous but-
ton or the next or previous menu in
a toolbar
£ ¢ , LEFT key
(when toolbar is active)
¦+c, ...
66 Endress+Hauser
ToF Tool 9 FAQs (Frequently Asked Questions)
Access to serial interface Serial interface busy. If a program In the "Options" menu, select the
which accesses the serial interface "Settings" option.
is installed (but is not currently Check to see if the serial interface
active), is already being used by another
ToF Tool cannot communicate device (mouse, Commuwin II etc.).
(without the appropriate error mes-
sage).
Opening pdf files If the "Open" option is selected in Select the "View documentation"
the "File" menu, pdf files cannot be option in the "File" menu. Acrobat
opened. Reader
starts automatically.
Previously created meas- No envelope curve was opened Open envelope curve before
uring point documentation before creating the creating the documentation
does not documentation. (only the those curves shown in
contain any envelope the last envelope curve view are
curves. accepted in the documentation).
The envelope curve is The microfactor was also applied to Refer to the highlighting for the
shifted to the left for the Z distance. measurement distance.
bypass measurements.
The highlight is still at the
right point.
JPG is not displayed. The graphics are not shown Install Internet Explorer (Version
because they are permanently 5.x or higher).
assigned to another application.
During cyclic envelope The envelope curve file could not be Envelope curves can be renamed
curve creation, a system saved properly. from TMP files to CRV files and
crash (e.g. due to power then accessed.
failure) leads to data loss.
ToF devices which do If a ToF device is taken from the bus Select the "New Device List..."
not exist are in the device and rescanned, the device stays in option in the "File" menu and res-
list. the device list and the icon is can the bus.
crossed through.
The operating system says Swap file (virtual memory) is not big Increase swap file.
it enough.
has insufficient memory.
During cyclic envelope Storing a large number of envelope Increase main memory or await
curve creation the storing curves (> 1000) may demand long storing procedure.
procedure takes a very time (> 10 min).
long time.
Several hundreds of over- After switching to a new configura- Unselect "Overlapped Curve" in
lapping envelope curves tion group it takes a while before the the Envelope menu before switch-
have been plotted. new group is displayed. ing to the new configuration group.
The ToF-Tool has been Occasionally, proper termination of Close the processes via the Task
quitted and can not be the processes (ToF*.exe and Manager or reboot the computer.
started again. PB_DPV*.exe) may fail. If so, the Afterwards the ToF tool can be
ToF-Tool can not be started again. started again.
A bus scan has been per- Not all devices, that have been Devices are only displayed, if the
formed and the saved present on the bus, are displayed. respective device description is
device list is to be available.
restored.
Endress+Hauser 67
9 FAQs (Frequently Asked Questions) ToF Tool
In the case of saved enve- Only the last MAP read is saved in Save previously loaded envelope
lope curves, MAP does not each envelope curve file (from ToF curves in a separate file before
match all such curves if Tool version 3.1 onwards a MAP is changing the MAP
the MAP was changed saved together with every envelope
and reloaded during curve).
recording
The MAP is not displayed. MAP must be loaded separately In the "Envelope Curves" menu,
(usually only once is necessary) select the "Read MAP" option to
load the MAP
The ToF-Tool does not set A Proficard driver of less than Install the current driver (contained
up a connection with the V 5.22 is installed on the CD in the "Drivers" direc-
Proficard tory)
The display of the first The peak value of the highest echo This function is only implemented
echo band does not begin was not saved with the envelope with the display of the current echo
at the peak of the highest curve
echo
Download to the device The communication interfaces used Use the same communication
failed for the uploads and downloads are interface
not identical (poss. make remark in file name)
After an update of the ToF- The installation process was inter- Complete the installation process
Tool, no instrument rupted after the restart after restart by adding the device
descriptions are available descriptions
The upload file cannot be No offline functionality implemented Create documentation when the
viewed offline device is online
The envelope curve is not Via the Curve menu it is only possi- The curves must be read in via the
displayed, although the ble to display but not to read in the Envelope menu or via the recorder
respective checkbox has curves. symbols.
been marked.
Installation on Win 2000 or Access rights are not sufficient. Ensure sufficient administrator
Win XP is terminated after access rights (see Installation
a few percent. Instructions)
Start of the parameter edi- Missing write permission in the "pro- Ensure that sufficient rights are
tor of the ToF Tool fails gram files" directory established by the administrator
under Win XP (see Installation Instructions).
68 Endress+Hauser
ToF Tool Index
Index
A History Forward . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Add Demo Device. . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Arrange Icons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 I
Import. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
C Info about Tof Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Cascade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Input Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Cascaded Curve. . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Insert Row (Ins) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Clear All Rows. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Clear Plot Display . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Clear Selected Rows. . . . . . . . . . . . . . . . . . . . . . . . . 28 K
Close . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Key combinations . . . . . . . . . . . . . . . . . . . . . . . . 63–66
Configuration menu. . . . . . . . . . . . . . . . . . . . . . . . . . 16
Connect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
L
Last Envelope Curve . . . . . . . . . . . . . . . . . . . . . . . . . 39
Create Documentation... . . . . . . . . . . . . . . . . . . . . . . 14
Linearisation Table dialog box . . . . . . . . . . . . . . . . . . 52
Curve Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Load Ideal Echo Curve... . . . . . . . . . . . . . . . . . . . . . . 42
Cyclic Read. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Cyclic Read Settings... . . . . . . . . . . . . . . . . . . . . . . . 35 M
D Main screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Data at Cursor Position . . . . . . . . . . . . . . . . . . . . . . . 57 Menu bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Delete Selected Rows (Del) . . . . . . . . . . . . . . . . . . . 28 Modem Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Move Ideal Echo Curve To Peak . . . . . . . . . . . . . . . . 42
Device data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 N
Device List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16, 59
Navigating ToF Tool . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Navigation Bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Devices register card . . . . . . . . . . . . . . . . . . . . . . . . 60
New Device List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Dial Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Next Envelope Curve . . . . . . . . . . . . . . . . . . . . . . . . . 39
Disconnect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Display Envelope Curve.... . . . . . . . . . . . . . . . . . . . . 37 O
Download . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Open (CTRL+O). . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Open In Current Window ... . . . . . . . . . . . . . . . . . . . . 11
E
Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Edit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Edit Cell (F2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 P
Edit Parameter List . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Parameter List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Edit Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Parameterisation Editor . . . . . . . . . . . . . . . . . . . . . . . 46
End Read . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Envelope Curve. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Parameters dialog box. . . . . . . . . . . . . . . . . . . . . . . . 48
Envelope Curve dialog box. . . . . . . . . . . . . . . . . 54–55 Previous Envelope Curve. . . . . . . . . . . . . . . . . . . . . . 39
Envelope Curve Editor Help . . . . . . . . . . . . . . . . . . . 45 Print Setup.... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Envelope Curve List . . . . . . . . . . . . . . . . . . . . . . . . . 57 Print... (CTRL+P) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6, 16 Print… (CTRL+P) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Export . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Properties... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Export To File... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Extract... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 R
Read Curve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
F Read Settings... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Fast Forward . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Read TDT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Fast Reverse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Recent Device List . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Recent Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
First Envelope Curve. . . . . . . . . . . . . . . . . . . . . . . . . 39 Remarks... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42, 58
Footer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Remove Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Forward . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Reset Reading Range . . . . . . . . . . . . . . . . . . . . . . . . 35
Reverse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
H
Run QH Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Help. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
History Back . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Endress+Hauser 69
Index ToF Tool
S Title bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Save (CTRL+S) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Toolbar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8, 16
Save As... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Save Device List As... . . . . . . . . . . . . . . . . . . . . . . . . 10 U
Save Device List.... . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Undo (CTRL+Z) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Scan... (F5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Upload . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Scope of delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 User Info... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Set Address. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 User interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Settings... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Show Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
V
View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
View Documentation... . . . . . . . . . . . . . . . . . . . . . . . 15
Status Bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8, 16, 62
View Log... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
T
Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
W
Window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
TAG‘s register card . . . . . . . . . . . . . . . . . . . . . . . . . . 61
TAGs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Tile. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
70 Endress+Hauser
ToF Tool Index
Endress+Hauser 71
Netherlands Bolivia Pakistan
Europe Endress+Hauser B.V. Tritec S.R.L. Speedy Automation
Naarden Cochabamba Karachi
Austria Tel. (035) 6958611, Fax (035) 6958825 Tel. (042) 56993, Fax (042) 50981 Tel. (021) 7722953, Fax (021) 7736884
Endress+Hauser Ges.m.b.H. Norway Brazil Philippines
Wien
Tel. (01) 88056-0, Fax (01) 88056-35 Endress+Hauser A/S Samson Endress+Hauser Ltda. Endress+Hauser Philippines Inc.
Tranby Sao Paulo Metro Manila
Belarus Tel. (032) 859850, Fax (032) 859851 Tel. (011) 50313455, Fax (011) 50313067 Tel. (2) 3723601-05, Fax (2) 4121944
Belorgsintez Poland Canada Singapore
Minsk
Tel. (0172) 508473, Fax (0172) 508583 Endress+Hauser Polska Sp. z o.o. Endress+Hauser Ltd. Endress+Hauser (S.E.A.) Pte., Ltd.
Wroclaw Burlington, Ontario Singapore
Belgium / Luxembourg Tel. (022) 7803723, Fax (022) 7803760 Tel. (905) 6819292, Fax (905) 6819444 Tel. 5668222, Fax 5666848
Endress+Hauser N.V. Portugal Chile South Korea
Brussels
Tel. (02) 2480600, Fax (02) 2480553 Tecnisis - Tecnica de Sistemas Industriais Endress+Hauser Chile Ltd. Endress+Hauser (Korea) Co., Ltd.
Linda-a-Velha Santiago Seoul
Bulgaria Tel. (21) 4267290, Fax (21) 4267299 Tel. (02) 321-3009, Fax (02) 321-3025 Tel. (02) 6587200, Fax (02) 6592838
INTERTECH-AUTOMATION
Sofia Romania Colombia Taiwan
Tel. (02) 664869, Fax (02) 9631389 Romconseng S.R.L. Colsein Ltda. Kingjarl Corporation
Bucharest Bogota D.C. Taipei R.O.C.
Croatia Tel. (01) 4101634, Fax (01) 4112501 Tel. (01) 2367659, Fax (01) 6104186 Tel. (02) 27183938, Fax (02) 27134190
Endress+Hauser GmbH+Co. Russia Costa Rica Thailand
Zagreb
Tel. (01) 6637785, Fax (01) 6637823 Endress+Hauser Moscow Office EURO-TEC S.A. Endress+Hauser Ltd.
Moscow San Jose Bangkok
Cyprus Tel. (095) 1587564, Fax (095) 1589871 Tel. (02) 961542, Fax (02) 961542 Tel. (2) 9967811-20, Fax (2) 9967810
I+G Electrical Services Co. Ltd.
Nicosia Slovakia Ecuador Vietnam
Tel. (02) 484788, Fax (02) 484690 Transcom Technik s.r.o. Insetec Cia. Ltda. Tan Viet Bao Co. Ltd.
Bratislava Quito Ho Chi Minh City
Czech Republic Tel. (7) 44888684, Fax (7) 44887112 Tel. (02) 269148, Fax (02) 461833 Tel. (08) 8335225, Fax (08) 8335227
Endress+Hauser GmbH+Co. Slovenia Iran
Praha Guatemala
Tel. (026) 6784200, Fax (026) 6784179 Endress+Hauser D.O.O. ACISAAutomatizacionYControlIndustrial S.A. PATSA Co.
Ljubljana Ciudad de Guatemala, C.A. Tehran
Denmark Tel. (01) 5192217, Fax (01) 5192298 Tel. (03) 345985, Fax (03) 327431 Tel. (021) 8754748, Fax(021) 8747761
Endress+Hauser A/S Spain
Søborg Mexico Israel
Tel. (70) 131132, Fax (70) 132133 Endress+Hauser S.A. Endress+Hauser S.A. de C.V. Instrumetrics Industrial Control Ltd.
Sant Just Desvern Mexico City Tel-Aviv
Estonia Tel. (93) 4803366, Fax (93) 4733839 Tel. (5) 5682405, Fax (5) 5687459 Tel. (09) 8357090, Fax (09) 8350619
ELVI-Aqua
Sweden Paraguay Jordan
Tartu
Tel. (7) 441638, Fax (7) 441582 Endress+Hauser AB Incoel S.R.L A.P. Parpas Engineering S.A.
Sollentuna .Asuncion Amman
Finland Tel. (08) 55511600, Fax (08) 55511655 Tel. (021) 213989, Fax (021) 226583 Tel. (06) 4643246, Fax (06) 4645707
Endress+Hauser Oy Switzerland Uruguay Kingdom of Saudi Arabia
Helsinki
Tel. (0204) 83160, Fax (0204) 83161 Endress+Hauser Metso AG Circular S.A. Anasia Ind. Agencies
Reinach/BL 1 Montevideo Jeddah
France Tel. (061) 7157575, Fax (061) 7111650 Tel. (02) 925785, Fax (02) 929151 Tel. (02) 6710014, Fax (02) 6725929
Endress+Hauser S.A. Turkey
Huningue USA Lebanon
Tel. (389) 696768, Fax (389) 694802 Intek Endüstriyel Ölcü ve Kontrol SistemleriIs-
tanbul
Endress+Hauser Inc. Network Engineering
Greenwood, Indiana Jbeil
Germany Tel. (0212) 2751355, Fax (0212) 2662775 Tel. (317) 535-7138, Fax (317) 535-8498 Tel. (3) 944080, Fax (9) 548038
Endress+HauserMesstechnik GmbH+Co. Ukraine
Weil am Rhein Venezuela Sultanate of Oman
Tel. (07621) 975-01, Fax (07621) 975-555 Photonika GmbH Controval C.A. Mustafa & Sultan Sience & Industry Co. L.L.C.
Kiev Caracas Ruwi
Great Britain Tel. (44) 26881, Fax (44) 26908 Tel. (02) 9440966, Fax (02) 9444554 Tel. 602009, Fax 607066
Endress+Hauser Ltd.
Manchester Yugoslavia Rep. United Arab Emirates
Tel. (0161) 2865000, Fax (0161) 9981841 Meris d.o.o. Descon Trading EST.
Beograd Asia Dubai
Greece Tel.(11) 4441966, Fax (11) 4441966 Tel. (04) 2653651, Fax (04) 2653264
I & G Building Services Automation S.A. China
Athens
Tel. (01) 9241500, Fax (01) 9221714
Endress+Hauser Shanghai Yemen
Africa Instrumentation Co. Ltd. YemenCompany for Ghee and Soap Industry
Shanghai Taiz
Hungary Tel. (021) 54902300, Fax (021) 54902303 Tel. (04) 230664, Fax (04) 212338
Mile Ipari-Elektro Egypt
Budapest Anasia Endress+Hauser Beijing Office
Tel. (01) 4319800, Fax (01) 4319817 Heliopolis/Cairo Beijing
Tel. (02) 4179007, Fax (02) 4179008 Tel. (010) 68344058, Fax: (010) 68344068 Australia + New Zealand
Iceland
BIL ehf Morocco Hong Kong
Reykjavik Oussama S.A. Endress+Hauser HK Ltd. Australia
ALSTOM Australia Limited
Tel. (05) 619616, Fax (05) 619617 Casablanca Hong Kong
Tel. 25283120, Fax 28654171 Milperra
Tel. (02) 241338, Fax (02) 402657 Tel. (02) 97747444, Fax (02) 97744667
Ireland
Flomeaco Company Ltd. South Africa India
Kildare Endress+Hauser Pty. Ltd. Endress+Hauser (India) Pvt. Ltd. New Zealand
EMC Industrial Group Limited
Tel. (045) 868615, Fax (045) 868182 Sandton Mumbai
Tel. (022) 8521458, Fax (022) 8521927 Auckland
Tel. (011) 26280000, Fax (011) 2628062 Tel. (09) 4155110, Fax (09) 4155115
Italy
Endress+Hauser S.p.A. Tunisia Indonesia
Cernusco s/N Milano Controle, Maintenance et Regulation PT Grama Bazita
Tel. (02) 92192-1, Fax (02) 92192-362 Tunis Jakarta All other countries
Tel. (01) 793077, Fax (01) 788595 Tel. (21) 7975083, Fax (21) 7975089
Latvia
Rino TK Japan
Riga Sakura Endress Co. Ltd. Endress+Hauser GmbH+Co. KG
Tel. (07) 315087, Fax (07) 315084 America Tokyo Instruments International
Tel. (0422) 540613, Fax (0422) 550275 Weil am Rhein
Lithuania Germany
Argentina
UAB "Agava"
Kaunas
Endress+Hauser Argentina S.A. Malaysia
Endress+Hauser (M) Sdn. Bhd.
Tel. (07621) 975-02, Fax (07621) 975-345
Buenos Aires
Tel. (07) 202410, Fax (07) 207414 Tel. (01) 145227970, Fax (01) 145227909 Petaling Jaya, Selangor Darul Ehsan
Tel. (03) 7334848, Fax (03) 7338800
http://www.endress.com
BA 224F/00/en/05.02
CCS / FM+SGML 6.0