CALCULATION OF WIND LOAD IS CODE 875(PART 3) 1987

Height of the story= 3m


Number of stories= 10
Height of the structure= 30 m

1 Design wind speed(Vz)= Vbk1k2k3 clause 5


Vz= Design wind speed at any height (H) in m/s
Vb = Basic wind speed
k1= Probability factor(Risk coefficent)(clause 5.3.1) Table 1
k2= Terrain roughness and height factor(caluse 5.3.2) Table 2
k3= Topography factor(clause 5.3.3)
Vb = 44 m/s as per code
k1= 1
k2= 1.03
Terrain Category = 3 (caluse 5.3.2.1)
Greatest dimention = h=30m (20-50m) as per code
Structure Category Class B
height k2 (caluse 5.3.2.2)
10m 0.88
15m 0.94
20m 0.98
30m 1.03

k3= 1+Cs if ϴ<3 degree k3 = 1


Being Hilly region if ϴ>3 degree k3= 1 to 1.36
Cs= 0.36
k3= 1
height k1 k2 k3 Vb
10m 1 0.88 1 44
15m 1 0.94 1 44
20m 1 0.98 1 44
30m 1 1.03 1 44

2 Design wind pressure (Pz)= 0.6Vz2 (Clause 5.4)


height Vz Pz unit
10m 38.72 899.54304 N/m2
15m 41.36 1026.38976 N/m2
20m 43.12 1115.60064 N/m2
30m 45.32 1232.34144 N/m2

3 Design wind load (F)= Cf*Ae*Pz


Cf= force coefficent of building
Ae= effective frontal area(directly incontact with building)
Pz= design wind load
for Cf IS code875 page 39
a= 15 m
b= 24 m
h= 30 m
a/b= 0.625 m
h/b= 1.25 m
Cf>1 figure 4A is taken from graph
Cf= 1.2
Ae= 6 m2 (per bay per meter height of the structure)

height Pz F=Cf*Ae*Pz(N/m) F=Cf*Ae*Pz(KN/m)


10m 899.54304 6476.709888 6.48
15m 1026.3898 7390.006272 7.39
20m 1115.6006 8032.324608 8.03
30m 1232.3414 8872.858368 8.87
3.1) Table 1
5.3.2) Table 2

a=15m

b=24m a=15m
(clause 5.3.3.1) plan elevation

wind

Vz unit
38.72 m/s
41.36 m/s
43.12 m/s
45.32 m/s
ht of the structure)

5
6 6 6

wind
h=30m
6
CALCULATION OF WIND LOAD IS CODE 875(PART 3) 1987

1 Given data
Span of roof truss = 15 m
Half length of roof truss= 7.5 m
Spacing of truss = 4 m c/c
Rise(Height) of truss = 3m
Height of truss above ground level= 20 m
Total number of pannels= 8 nos.

2 Preliminary calculation =
A. Angle of roof truss (α)=
tanα= 0.53
α= 21.8
B. Length of principal rafter= 8.08 m

C. Half plan area= 30 m2


D. Half slope area= 32.31 m2

3 Dead load calculation IS CODE 875(PART 1) 1987


a Weight of roofing material
For ACC sheet@ 150 N/m2 (on slope area)
Weight of roofing material = 4846.65 N

b Weight of purlin =
weight of purlin = 120 N/m2 (on plan area)
weight of purlin = 3600 N

c Self weight of roof truss


Self weight = 10(span/3+5) N/m2 (equation should be remembered)
100 N/m2 (on plan area)
Self weight = 3000 N

d Weight of wind bracing= 12 N/m2 (on plan area)


360 N

e Total Deadload = 11806.65 N


FPP on one side of truss = 4 nos.
DL per pannel point= 2951.66 N

4 Calculation of wind load IS CODE 875(PART3) 1987


Design wind speed(Vz)= Vbk1k2k3 clause 5.3,page 8
Vz= Design wind speed at any height (H) in m/s
Vb = Basic wind speed
k1= Probability factor(Risk coefficent)(clause 5.3.1) Table
k2= Terrain roughness and height factor(caluse 5.3.2) Table
k3= Topography factor(clause 5.3.3)
Vb = 39 m/s (page 53,appendex A,fig.1)
k1= 0.92 (for 25 years return period)
k2= 1.01 (caluse 5.3.2.2)
Terrain Category = 3 (caluse 5.3.2.1)
Greatest dimention = 20 (20-50m) as per code
Structure Category Class A
k3= 1+Cs if ϴ<3 degree k3 = 1 (clause 5.3.3.1), append
Being Hilly region if ϴ>3 degree k3= 1 to 1.36
Cs= 0.36
k3= 1
Vz= 36.24 m/s
5 Design wind pressure (Pz)
Pz= 0.6Vz2 IS 875,page 12,clause 5.4
787.95 N/m2

6 Wind load calculation (F)


F= (Cpe±Cpi)*A*Pz IS 875,page 13,clause 6.2.1
Cpe= external pressure coefficent
Cpi= internal pressure coefficent
A= surface area of structural element
Pz= design wind pressure
calculation of external pressure coefficent IS 875,page 16,table 5
h/w= 1.33 0.5<h/w<1.5 case 2
h= heigth of roof truss from ground level
w= span or length of roof truss

For wind angle ϴ=0⁰


EF side GH side
angle Cpe
for α= 20 -0.7 α=21.8
for α= 30 -0.2 Cpe=
difference 10 -0.5
for α= 10 -0.5
for α=1.8 1.8 0.09
for α= 20 -0.7
for α=21.8 21.8 -0.61
For wind angle ϴ=90⁰
EG side
angle Cpe
for α 21.8 -0.8 for α=
for α=
difference
for α=
for α=1.8
for α=
for α=21.8
taking maximum value from 4 value
Cpe= -0.8

calculation of internal pressure coefficent(Cpi)


Cpi=± 0.5 IS 875,page 27&36,clause 6.2.3
wall opening 10%
F= (Cpe±Cpi)*A*Pz
-33097.29 N (total weight)
negative sign indicates suction
Wind load for FPP= -8274.32 N
-8.27 KN
Wind load for EPP= -4.14 KN
4

Truss plan
15

3m

e remembered)
side view
15 m

0.5EPP 0.5EPP

1FPP 1FPP
1FPP 1FPP
1FPP 1FPP

0.5EPP

FPP=FULL PANEL PONT( i.e. 1 panel point)


ht (H) in m/s END PANEL POINT(i.e.half panel point or 0.5 panel point)

nt)(clause 5.3.1) Table ,page 11


ctor(caluse 5.3.2) Table,page 12 15 m

7.5 m
half length of roof truss

(clause 5.3.3.1), appendex c,page 56

ϴ=90⁰ ϴ=90⁰

ϴ=0⁰ E G ϴ=0⁰

ϴ=0⁰ F H ϴ=0⁰

plan of roof truss


ϴ=90⁰ ϴ=90⁰

-0.5
FH side
angle Cpe
20 -0.6
30 -0.8
10 -0.2
10 -0.2
1.8 0.036
20 -0.6
0 -0.636
truss 4 (PR)

truss 3 (PR)

truss 2 (PR)

truss 1 (PR)

20 m

0.5EPP
el point or 0.5 panel point)