CALCULATION SHEET
FOR IMPRESSED CURRENT CATHODIC PROTECTION SYSTEM (DEEPWELL TYPE)
ICCP LOCATION:
SERVICE: PIPELINE PROJECT

DATA :
CURRENT DENSITY USED (Cd)
Cd at 25oC
Pipe Description Size Temp (°C) Coating Type
(mA/m2)
Sales Gas Pipeline 24 inch 65.6 3 Layer PE 20

CURRENT RATING OF MMO ANODE, M754 (Cap) 5.1 Amp


CONSUMPTION RATE OF MMO ANODE, M754 (Con) 0.001 kg/amp-year
WEIGHT OF MMO ANODE, M754 (W) 0.3828 kg
VOLTAGE DESIGN FACTOR (df) 1.25
CURRENT SAFETY FACTOR (Sf) 1.25
COATING BREAKDOWN FACTOR (Cb) 1.20%
BACK EMF (Vb) 2.00 V
ANODE UTILIZATION FACTOR (U) 0.90
DESIGN LIFE TIME (Y) 20.00 years

RESISTANCE
A. Cable Resistance
Resistance Resistance
Description Size Length (m)
(ohm/m) (ohm)
Main Positive Cable 35 mm2 163 0.000387 0.0631
Anode cable 16 mm2 94 0.001150 0.1081
Main Negative Cable 35 mm2 13 0.000387 0.0050
Drain Point Cable 35 mm2 22 0.000387 0.0085
Total Cable Resistance 0.1847

B. Groundbed to Earth Resistance


Anode Diameter Anode Soil Resistivity Resistance
Description
(inch) (m) Length (m) (ohm-cm) (ohm)
Groundbed 1 8 0.2032 30 3500 1.1279
Groundbed 2 8 0.2032 30 3500 1.1279
Groundbed 3 8 0.2032 30 3500 1.1279
Groundbed 4 8 0.2032 30 3500 1.1279
Total Resistance Groundbed in Parallel 0.2820

C. Pipeline to Earth Resistance


Pipe Diameter Pipe Length Soil Resistivity Depth to
Description
(inch) (m) (m) (ohm-cm) center (m)
Pipeline to earth 24 0.6096 67000 3500 2

GRAND TOTAL RESISTANCE

DESIGN CURRENT REQUIREMENT


L d A Ip If
Pipe Description
(m) (m) (m )
2
(amp) (amp)

Page 1 of 8
Rev :0
Date : 19 Dec 2013

CALCULATION SHEET
FOR IMPRESSED CURRENT CATHODIC PROTECTION SYSTEM (DEEPWELL TYPE)
ICCP LOCATION:
SERVICE: PIPELINE PROJECT

Sales Gas Pipeline 67000 0.6096 128312.70 93.31 116.64

TOTAL NUMBER OF ANODE BASED ON CURRENT OUTPUT (Nc)


Calculated 22.87 ea
Round Up 23.00 ea

Page 2 of 8
Rev :0
Date : 19 Dec 2013

CALCULATION SHEET
FOR IMPRESSED CURRENT CATHODIC PROTECTION SYSTEM (DEEPWELL TYPE)
ICCP LOCATION:
SERVICE: PIPELINE PROJECT

TOTAL NUMBER OF ANODE BASED ON WEIGHT (Nw)


Calculated 6.77 ea
Round Up 7.00 ea

SELECTED DESIGN TOTAL NUMBER OF ANODE 23.00 ea

NUMBER OF GROUNDBED
No. Anode per Groundbed 6.00 ea
Selected No. Groundbed 4.00 ea

RECTIFIER CALCULATION
Calculated IDC 117.30 A VDC 71.19 V
Selected Design IDC 118.00 A VDC 72.00 V

TRANSFORMER CAPACITY
Calculated 8.50 kVA
Selected Rating 9.00 kVA

Page 3 of 8
Rev :0
Date : 19 Dec 2013

CALCULATION SHEET
FOR IMPRESSED CURRENT CATHODIC PROTECTION SYSTEM (DEEPWELL TYPE)
ICCP LOCATION:
SERVICE: PIPELINE PROJECT

Page 4 of 8
DEEPWELL TYPE)

Cd final (mA/m2)

60.600

for 20 years

Resistance (ohm)

0.0018

0.4685

Page 5 of 8
DEEPWELL TYPE)

Page 6 of 8
DEEPWELL TYPE)

Page 7 of 8
DEEPWELL TYPE)

Page 8 of 8
Rev :0
Date : 22 Nov 2013

CALCULATION SHEET
FOR IMPRESSED CURRENT CATHODIC PROTECTION SYSTEM (DEEPWELL TYPE)
ICCP LOCATION: SKG RANTAU PANJANG
SERVICE: A HALF ALONG PIPELINE SKG RANTAU PANJANG TO SKG PANGKALAN BRANDAN (69 K

DATA :
CURRENT DENSITY USED (Cd)
Cd at 25oC
Pipe Description Size Temp (°C) Coating Type
(mA/m2)
Sales Gas Pipeline 24 inch 65.6 3 Layer PE 20

CURRENT RATING OF MMO ANODE, M754 (Cap) 5.1 Amp


CONSUMPTION RATE OF MMO ANODE, M754 (Con) 0.001 kg/amp-year
WEIGHT OF MMO ANODE, M754 (W) 0.3828 kg
VOLTAGE DESIGN FACTOR (df) 1.25
CURRENT SAFETY FACTOR (Sf) 1.25
COATING BREAKDOWN FACTOR (Cb) 1.20%
BACK EMF (Vb) 2.00 V
ANODE UTILIZATION FACTOR (U) 0.90
DESIGN LIFE TIME (Y) 20.00 years

RESISTANCE
A. Cable Resistance
Resistance Resistance
Description Size Length (m)
(ohm/m) (ohm)
Main Positive Cable 50 mm2 50 0.000387 0.0194
Anode cable 16 mm2 30 0.001150 0.0345
Main Negative Cable 50 mm2 200 0.000387 0.0774
Drain Point Cable 50 mm2 50 0.000387 0.0194
Total Cable Resistance 0.1506

B. Groundbed to Earth Resistance


Anode Diameter Anode Soil Resistivity Resistance
Description
(inch) (m) Length (m) (ohm-cm) (ohm)
Groundbed 1 8 0.2032 20 1000 0.4511
Groundbed 2 8 0.2032 20 1000 0.4511
Groundbed 3 8 0.2032 20 1000 0.4511
Groundbed 4 8 0.2032 20 1000 0.4511
Total Resistance Groundbed in Parallel 0.1128

C. Pipeline to Earth Resistance


Pipe Diameter Pipe Length Soil Resistivity Depth to
Description
(inch) (m) (m) (ohm-cm) center (m)
Pipeline to earth 24 0.6096 70000 1000 2.5

GRAND TOTAL RESISTANCE

DESIGN CURRENT REQUIREMENT


L d A Ip If
Pipe Description
(m) (m) (m )
2
(amp) (amp)

Page 9 of 8
Rev :0
Date : 22 Nov 2013

CALCULATION SHEET
FOR IMPRESSED CURRENT CATHODIC PROTECTION SYSTEM (DEEPWELL TYPE)
ICCP LOCATION: SKG RANTAU PANJANG
SERVICE: A HALF ALONG PIPELINE SKG RANTAU PANJANG TO SKG PANGKALAN BRANDAN (69 K

Sales Gas Pipeline 70000 0.6096 134058.04 97.49 121.86

TOTAL NUMBER OF ANODE BASED ON CURRENT OUTPUT (Nc)


Calculated 23.89 ea
Round Up 24.00 ea

Page 10 of 8
Rev :0
Date : 22 Nov 2013

CALCULATION SHEET
FOR IMPRESSED CURRENT CATHODIC PROTECTION SYSTEM (DEEPWELL TYPE)
ICCP LOCATION: SKG RANTAU PANJANG
SERVICE: A HALF ALONG PIPELINE SKG RANTAU PANJANG TO SKG PANGKALAN BRANDAN (69 K

TOTAL NUMBER OF ANODE BASED ON WEIGHT (Nw)


Calculated 7.07 ea
Round Up 8.00 ea

SELECTED DESIGN TOTAL NUMBER OF ANODE 24.00 ea

NUMBER OF GROUNDBED
No. Anode per Groundbed 6.00 ea
Selected No. Groundbed 4.00 ea

RECTIFIER CALCULATION
Calculated IDC 122.40 A VDC 42.87 V
Selected Design IDC 123.00 A VDC 43.00 V

TRANSFORMER CAPACITY
Calculated 5.29 kVA
Selected Rating 6.00 kVA

Page 11 of 8
Rev :0
Date : 22 Nov 2013

CALCULATION SHEET
FOR IMPRESSED CURRENT CATHODIC PROTECTION SYSTEM (DEEPWELL TYPE)
ICCP LOCATION: SKG RANTAU PANJANG
SERVICE: A HALF ALONG PIPELINE SKG RANTAU PANJANG TO SKG PANGKALAN BRANDAN (69 K

Page 12 of 8
DEEPWELL TYPE)

NGKALAN BRANDAN (69 KM)

Cd final (mA/m2)

60.600

for 20 years

Resistance (ohm)

0.0005

0.2639

Page 13 of 8
DEEPWELL TYPE)

NGKALAN BRANDAN (69 KM)

Page 14 of 8
DEEPWELL TYPE)

NGKALAN BRANDAN (69 KM)

Page 15 of 8
DEEPWELL TYPE)

NGKALAN BRANDAN (69 KM)

Page 16 of 8
Rev :0
Date : 22 Nov 2013

CALCULATION SHEET
FOR IMPRESSED CURRENT CATHODIC PROTECTION SYSTEM (DEEPWELL TYPE)
ICCP LOCATION: SKG RANTAU PANJANG
SERVICE: PIPELINE SKG RANTAU PANJANG TO SLSA (59 KM)

DATA :
CURRENT DENSITY USED (Cd)
Cd at 25oC
Pipe Description Size Temp (°C) Coating Type
(mA/m2)
Sales Gas Pipeline 24 inch 65.6 3 Layer PE 20

CURRENT RATING OF MMO ANODE, M754 (Cap) 5.1 Amp


CONSUMPTION RATE OF MMO ANODE, M754 (Con) 0.001 kg/amp-year
WEIGHT OF MMO ANODE, M754 (W) 0.3828 kg
VOLTAGE DESIGN FACTOR (df) 1.25
CURRENT SAFETY FACTOR (Sf) 1.25
COATING BREAKDOWN FACTOR (Cb) 1.20%
BACK EMF (Vb) 2.00 V
ANODE UTILIZATION FACTOR (U) 0.90
DESIGN LIFE TIME (Y) 20.00 years

RESISTANCE
A. Cable Resistance
Resistance Resistance
Description Size Length (m)
(ohm/m) (ohm)
Main Positive Cable 50 mm2 50 0.000387 0.0194
Anode cable 16 mm2 30 0.001150 0.0345
Main Negative Cable 50 mm2 200 0.000387 0.0774
Drain Point Cable 50 mm2 50 0.000387 0.0194
Total Cable Resistance 0.1506

B. Groundbed to Earth Resistance


Anode Diameter Anode Soil Resistivity Resistance
Description
(inch) (m) Length (m) (ohm-cm) (ohm)
Groundbed 1 8 0.2032 20 1000 0.4511
Groundbed 2 8 0.2032 20 1000 0.4511
Groundbed 3 8 0.2032 20 1000 0.4511
Total Resistance Groundbed in Parallel 0.1504

C. Pipeline to Earth Resistance


Pipe Diameter Pipe Length Soil Resistivity Depth to
Description
(inch) (m) (m) (ohm-cm) center (m)
Pipeline to earth 24 0.6096 59000 1000 2.5

GRAND TOTAL RESISTANCE

DESIGN CURRENT REQUIREMENT


L d A Ip If
Pipe Description
(m) (m) (m2) (amp) (amp)
Sales Gas Pipeline 59000 0.6096 112991.78 82.17 102.71

Page 17 of 8
Rev :0
Date : 22 Nov 2013

CALCULATION SHEET
FOR IMPRESSED CURRENT CATHODIC PROTECTION SYSTEM (DEEPWELL TYPE)
ICCP LOCATION: SKG RANTAU PANJANG
SERVICE: PIPELINE SKG RANTAU PANJANG TO SLSA (59 KM)

TOTAL NUMBER OF ANODE BASED ON CURRENT OUTPUT (Nc)


Calculated 20.14 ea
Round Up 21.00 ea

TOTAL NUMBER OF ANODE BASED ON WEIGHT (Nw)


Calculated 5.96 ea
Round Up 6.00 ea

Page 18 of 8
Rev :0
Date : 22 Nov 2013

CALCULATION SHEET
FOR IMPRESSED CURRENT CATHODIC PROTECTION SYSTEM (DEEPWELL TYPE)
ICCP LOCATION: SKG RANTAU PANJANG
SERVICE: PIPELINE SKG RANTAU PANJANG TO SLSA (59 KM)

SELECTED DESIGN TOTAL NUMBER OF ANODE 21.00 ea

NUMBER OF GROUNDBED
No. Anode per Groundbed 7.00 ea
Selected No. Groundbed 3.00 ea

RECTIFIER CALCULATION
Calculated IDC 107.10 A VDC 42.87 V
Selected Design IDC 108.00 A VDC 43.00 V

TRANSFORMER CAPACITY
Calculated 4.64 kVA
Selected Rating 5.00 kVA

Page 19 of 8
Rev :0
Date : 22 Nov 2013

CALCULATION SHEET
FOR IMPRESSED CURRENT CATHODIC PROTECTION SYSTEM (DEEPWELL TYPE)
ICCP LOCATION: SKG RANTAU PANJANG
SERVICE: PIPELINE SKG RANTAU PANJANG TO SLSA (59 KM)

Page 20 of 8
DEEPWELL TYPE)

A (59 KM)

Cd final (mA/m2)

60.600

for 20 years

Resistance (ohm)

0.0006

0.3015

Page 21 of 8
DEEPWELL TYPE)

A (59 KM)

Page 22 of 8
DEEPWELL TYPE)

A (59 KM)

Page 23 of 8
DEEPWELL TYPE)

A (59 KM)

Page 24 of 8
Rev :0
Date : 22 Nov 2013

CALCULATION SHEET
FOR IMPRESSED CURRENT CATHODIC PROTECTION SYSTEM (DEEPWELL TYPE)
ICCP LOCATION: SKG RANTAU PANJANG
SERVICE: A HALF ALONG PIPELINE SKG RANTAU PANJANG TO SKG PANGKALAN BRANDAN (69 K

DATA :
CURRENT DENSITY USED (Cd)
Cd at 25oC
Pipe Description Size Temp (°C) Coating Type
(mA/m2)
Sales Gas Pipeline 24 inch 65.6 3 Layer PE 20

CURRENT RATING OF MMO ANODE, M754 (Cap) 5.1 Amp


CONSUMPTION RATE OF MMO ANODE, M754 (Con) 0.001 kg/amp-year
WEIGHT OF MMO ANODE, M754 (W) 0.3828 kg
VOLTAGE DESIGN FACTOR (df) 1.25
CURRENT SAFETY FACTOR (Sf) 1.25
COATING BREAKDOWN FACTOR (Cb) 1.20%
BACK EMF (Vb) 2.00 V
ANODE UTILIZATION FACTOR (U) 0.90
DESIGN LIFE TIME (Y) 20.00 years

RESISTANCE
A. Cable Resistance
Resistance Resistance
Description Size Length (m)
(ohm/m) (ohm)
Main Positive Cable 50 mm2 50 0.000387 0.0194
Anode cable 16 mm2 30 0.001150 0.0345
Main Negative Cable 50 mm2 200 0.000387 0.0774
Drain Point Cable 50 mm2 50 0.000387 0.0194
Total Cable Resistance 0.1506

B. Groundbed to Earth Resistance


Anode Diameter Anode Soil Resistivity Resistance
Description
(inch) (m) Length (m) (ohm-cm) (ohm)
Groundbed 1 8 0.2032 20 2000 0.9022
Groundbed 2 8 0.2032 20 2000 0.9022
Groundbed 3 8 0.2032 20 2000 0.9022
Groundbed 4 8 0.2032 20 2000 0.9022
Total Resistance Groundbed in Parallel 0.2256

C. Pipeline to Earth Resistance


Pipe Diameter Pipe Length Soil Resistivity Depth to
Description
(inch) (m) (m) (ohm-cm) center (m)
Pipeline to earth 24 0.6096 69000 2000 2.5

GRAND TOTAL RESISTANCE

DESIGN CURRENT REQUIREMENT


L d A Ip If
Pipe Description
(m) (m) (m )
2
(amp) (amp)

Page 25 of 8
Rev :0
Date : 22 Nov 2013

CALCULATION SHEET
FOR IMPRESSED CURRENT CATHODIC PROTECTION SYSTEM (DEEPWELL TYPE)
ICCP LOCATION: SKG RANTAU PANJANG
SERVICE: A HALF ALONG PIPELINE SKG RANTAU PANJANG TO SKG PANGKALAN BRANDAN (69 K

Sales Gas Pipeline 69000 0.6096 132142.93 96.09 120.12

TOTAL NUMBER OF ANODE BASED ON CURRENT OUTPUT (Nc)


Calculated 23.55 ea
Round Up 24.00 ea

Page 26 of 8
Rev :0
Date : 22 Nov 2013

CALCULATION SHEET
FOR IMPRESSED CURRENT CATHODIC PROTECTION SYSTEM (DEEPWELL TYPE)
ICCP LOCATION: SKG RANTAU PANJANG
SERVICE: A HALF ALONG PIPELINE SKG RANTAU PANJANG TO SKG PANGKALAN BRANDAN (69 K

TOTAL NUMBER OF ANODE BASED ON WEIGHT (Nw)


Calculated 6.97 ea
Round Up 7.00 ea

SELECTED DESIGN TOTAL NUMBER OF ANODE 24.00 ea

NUMBER OF GROUNDBED
No. Anode per Groundbed 6.00 ea
Selected No. Groundbed 4.00 ea

RECTIFIER CALCULATION
Calculated IDC 122.40 A VDC 60.20 V
Selected Design IDC 123.00 A VDC 61.00 V

TRANSFORMER CAPACITY
Calculated 7.50 kVA
Selected Rating 8.00 kVA

Page 27 of 8
Rev :0
Date : 22 Nov 2013

CALCULATION SHEET
FOR IMPRESSED CURRENT CATHODIC PROTECTION SYSTEM (DEEPWELL TYPE)
ICCP LOCATION: SKG RANTAU PANJANG
SERVICE: A HALF ALONG PIPELINE SKG RANTAU PANJANG TO SKG PANGKALAN BRANDAN (69 K

Page 28 of 8
DEEPWELL TYPE)

NGKALAN BRANDAN (69 KM)

Cd final (mA/m2)

60.600

for 20 years

Resistance (ohm)

0.0010

0.3771

Page 29 of 8
DEEPWELL TYPE)

NGKALAN BRANDAN (69 KM)

Page 30 of 8
DEEPWELL TYPE)

NGKALAN BRANDAN (69 KM)

Page 31 of 8
DEEPWELL TYPE)

NGKALAN BRANDAN (69 KM)

Page 32 of 8
Rev :0
Date : 22 Nov 2013

CALCULATION SHEET
FOR IMPRESSED CURRENT CATHODIC PROTECTION SYSTEM (DEEPWELL TYPE)
ICCP LOCATION: SKG PANGKALAN BRANDAN
SERVICE: A HALF ALONG PIPELINE SKG PANGKALAN BRANDAN TO SKG RANTAU PANJANG (69 K

DATA :
CURRENT DENSITY USED (Cd)
Cd at 25oC
Pipe Description Size Temp (°C) Coating Type
(mA/m2)
Sales Gas Pipeline 24 inch 65.6 3 Layer PE 20

CURRENT RATING OF MMO ANODE, M754 (Cap) 5.1 Amp


CONSUMPTION RATE OF MMO ANODE, M754 (Con) 0.001 kg/amp-year
WEIGHT OF MMO ANODE, M754 (W) 0.3828 kg
VOLTAGE DESIGN FACTOR (df) 1.25
CURRENT SAFETY FACTOR (Sf) 1.25
COATING BREAKDOWN FACTOR (Cb) 1.20%
BACK EMF (Vb) 2.00 V
ANODE UTILIZATION FACTOR (U) 0.90
DESIGN LIFE TIME (Y) 20.00 years

RESISTANCE
A. Cable Resistance
Resistance Resistance
Description Size Length (m)
(ohm/m) (ohm)
Main Positive Cable 50 mm2 50 0.000387 0.0194
Anode cable 16 mm2 30 0.001150 0.0345
Main Negative Cable 50 mm2 200 0.000387 0.0774
Drain Point Cable 50 mm2 50 0.000387 0.0194
Total Cable Resistance 0.1506

B. Groundbed to Earth Resistance


Anode Diameter Anode Soil Resistivity Resistance
Description
(inch) (m) Length (m) (ohm-cm) (ohm)
Groundbed 1 8 0.2032 20 1000 0.4511
Groundbed 2 8 0.2032 20 1000 0.4511
Groundbed 3 8 0.2032 20 1000 0.4511
Groundbed 4 8 0.2032 20 1000 0.4511
Total Resistance Groundbed in Parallel 0.1128

C. Pipeline to Earth Resistance


Pipe Diameter Pipe Length Soil Resistivity Depth to
Description
(inch) (m) (m) (ohm-cm) center (m)
Pipeline to earth 24 0.6096 69000 1000 2.5

GRAND TOTAL RESISTANCE

DESIGN CURRENT REQUIREMENT


L d A Ip If
Pipe Description
(m) (m) (m )
2
(amp) (amp)

Page 33 of 8
Rev :0
Date : 22 Nov 2013

CALCULATION SHEET
FOR IMPRESSED CURRENT CATHODIC PROTECTION SYSTEM (DEEPWELL TYPE)
ICCP LOCATION: SKG PANGKALAN BRANDAN
SERVICE: A HALF ALONG PIPELINE SKG PANGKALAN BRANDAN TO SKG RANTAU PANJANG (69 K

Sales Gas Pipeline 69000 0.6096 132142.93 96.09 120.12

TOTAL NUMBER OF ANODE BASED ON CURRENT OUTPUT (Nc)


Calculated 23.55 ea
Round Up 24.00 ea

Page 34 of 8
Rev :0
Date : 22 Nov 2013

CALCULATION SHEET
FOR IMPRESSED CURRENT CATHODIC PROTECTION SYSTEM (DEEPWELL TYPE)
ICCP LOCATION: SKG PANGKALAN BRANDAN
SERVICE: A HALF ALONG PIPELINE SKG PANGKALAN BRANDAN TO SKG RANTAU PANJANG (69 K

TOTAL NUMBER OF ANODE BASED ON WEIGHT (Nw)


Calculated 6.97 ea
Round Up 7.00 ea

SELECTED DESIGN TOTAL NUMBER OF ANODE 24.00 ea

NUMBER OF GROUNDBED
No. Anode per Groundbed 6.00 ea
Selected No. Groundbed 4.00 ea

RECTIFIER CALCULATION
Calculated IDC 122.40 A VDC 42.87 V
Selected Design IDC 123.00 A VDC 43.00 V

TRANSFORMER CAPACITY
Calculated 5.29 kVA
Selected Rating 6.00 kVA

Page 35 of 8
Rev :0
Date : 22 Nov 2013

CALCULATION SHEET
FOR IMPRESSED CURRENT CATHODIC PROTECTION SYSTEM (DEEPWELL TYPE)
ICCP LOCATION: SKG PANGKALAN BRANDAN
SERVICE: A HALF ALONG PIPELINE SKG PANGKALAN BRANDAN TO SKG RANTAU PANJANG (69 K

Page 36 of 8
DEEPWELL TYPE)
N
G RANTAU PANJANG (69 KM)

Cd final (mA/m2)

60.600

for 20 years

Resistance (ohm)

0.0005

0.2639

Page 37 of 8
DEEPWELL TYPE)
N
G RANTAU PANJANG (69 KM)

Page 38 of 8
DEEPWELL TYPE)
N
G RANTAU PANJANG (69 KM)

Page 39 of 8
DEEPWELL TYPE)
N
G RANTAU PANJANG (69 KM)

Page 40 of 8
Rev :0
Date : 22 Nov 2013

CALCULATION SHEET
FOR IMPRESSED CURRENT CATHODIC PROTECTION SYSTEM (DEEPWELL TYPE)
ICCP LOCATION: SKG PANGKALAN BRANDAN
SERVICE: PIPELINE SKG PANGKALAN BRANDAN TO PLTGU SICANANG (71 KM)

DATA :
CURRENT DENSITY USED (Cd)
Cd at 25oC
Pipe Description Size Temp (°C) Coating Type
(mA/m2)
Sales Gas Pipeline 24 inch 65.6 3 Layer PE 20

CURRENT RATING OF MMO ANODE, M754 (Cap) 5.1 Amp


CONSUMPTION RATE OF MMO ANODE, M754 (Con) 0.001 kg/amp-year
WEIGHT OF MMO ANODE, M754 (W) 0.3828 kg
VOLTAGE DESIGN FACTOR (df) 1.25
CURRENT SAFETY FACTOR (Sf) 1.25
COATING BREAKDOWN FACTOR (Cb) 1.20%
BACK EMF (Vb) 2.00 V
ANODE UTILIZATION FACTOR (U) 0.90
DESIGN LIFE TIME (Y) 20.00 years

RESISTANCE
A. Cable Resistance
Resistance Resistance
Description Size Length (m)
(ohm/m) (ohm)
Main Positive Cable 50 mm2 50 0.000387 0.0194
Anode cable 16 mm2 30 0.001150 0.0345
Main Negative Cable 50 mm2 200 0.000387 0.0774
Drain Point Cable 50 mm2 50 0.000387 0.0194
Total Cable Resistance 0.1506

B. Groundbed to Earth Resistance


Anode Diameter Anode Soil Resistivity Resistance
Description
(inch) (m) Length (m) (ohm-cm) (ohm)
Groundbed 1 8 0.2032 20 1000 0.4511
Groundbed 2 8 0.2032 20 1000 0.4511
Groundbed 3 8 0.2032 20 1000 0.4511
Groundbed 4 8 0.2032 20 1000 0.4511
Total Resistance Groundbed in Parallel 0.1128

C. Pipeline to Earth Resistance


Pipe Diameter Pipe Length Soil Resistivity Depth to
Description
(inch) (m) (m) (ohm-cm) center (m)
Pipeline to earth 24 0.6096 71000 1000 2.5

GRAND TOTAL RESISTANCE

DESIGN CURRENT REQUIREMENT


L d A Ip If
Pipe Description
(m) (m) (m )
2
(amp) (amp)

Page 41 of 8
Rev :0
Date : 22 Nov 2013

CALCULATION SHEET
FOR IMPRESSED CURRENT CATHODIC PROTECTION SYSTEM (DEEPWELL TYPE)
ICCP LOCATION: SKG PANGKALAN BRANDAN
SERVICE: PIPELINE SKG PANGKALAN BRANDAN TO PLTGU SICANANG (71 KM)

Sales Gas Pipeline 71000 0.6096 135973.16 98.88 123.60

TOTAL NUMBER OF ANODE BASED ON CURRENT OUTPUT (Nc)


Calculated 24.24 ea
Round Up 25.00 ea

Page 42 of 8
Rev :0
Date : 22 Nov 2013

CALCULATION SHEET
FOR IMPRESSED CURRENT CATHODIC PROTECTION SYSTEM (DEEPWELL TYPE)
ICCP LOCATION: SKG PANGKALAN BRANDAN
SERVICE: PIPELINE SKG PANGKALAN BRANDAN TO PLTGU SICANANG (71 KM)

TOTAL NUMBER OF ANODE BASED ON WEIGHT (Nw)


Calculated 7.18 ea
Round Up 8.00 ea

SELECTED DESIGN TOTAL NUMBER OF ANODE 28.00 ea

NUMBER OF GROUNDBED
No. Anode per Groundbed 7.00 ea
Selected No. Groundbed 4.00 ea

RECTIFIER CALCULATION
Calculated IDC 127.50 A VDC 44.55 V
Selected Design IDC 128.00 A VDC 45.00 V

TRANSFORMER CAPACITY
Calculated 5.76 kVA
Selected Rating 6.00 kVA

Page 43 of 8
Rev :0
Date : 22 Nov 2013

CALCULATION SHEET
FOR IMPRESSED CURRENT CATHODIC PROTECTION SYSTEM (DEEPWELL TYPE)
ICCP LOCATION: SKG PANGKALAN BRANDAN
SERVICE: PIPELINE SKG PANGKALAN BRANDAN TO PLTGU SICANANG (71 KM)

Page 44 of 8
DEEPWELL TYPE)
N
ICANANG (71 KM)

Cd final (mA/m2)

60.600

for 20 years

Resistance (ohm)

0.0005

0.2639

Page 45 of 8
DEEPWELL TYPE)
N
ICANANG (71 KM)

Page 46 of 8
DEEPWELL TYPE)
N
ICANANG (71 KM)

Page 47 of 8
DEEPWELL TYPE)
N
ICANANG (71 KM)

Page 48 of 8