Escolar Documentos
Profissional Documentos
Cultura Documentos
CODE OF THE
PHILIPPINES
CHAPTER 4
STRUCTURAL CONCRETE
Section 405.3 Load Factors and Combinations
Load Designation Equation Primary Load
U = 1.4D (405.31a) D
U = 1.2D + 1.6L + 0.5 (Lr or R) (405.31b) L
U = 1.2D + 1.6 (Lr or R) + (1L or 0.5W) (405.31c) Lr or R
U = 1.2 D + 1W +1L + 0.5 (Lr or R) (405.31d) W
U = 1.2D + 1E + 1L (405.31e) E
U = 0.9D + 1W (405.31f) W
U = 0.9D + 1E (405.31g) E
405.3.2 The load factor on live load L in Eqs. 405.3.1c, 405.3.1d, and 405.3.1e shall be
permitted to be reduced to 0.5 except for (a), (b), or (c):
a. Garages;
b. Areas occupied as places of public assembly;
c. Areas where L is greater than 4.8 kPa.
and
𝑘𝑙𝑢
≤ 40 (406.2.5c)
𝑟
𝑀
Where 𝑀1 is negative if the column is bent in single curvature, and positive for double
2
curvature.
If bracing elements resisting lateral movement of a storey have a total stiffness of at least 12
times the gross lateral stiffness of the columns in the direction considered, it shall be permitted to
consider columns within the storey to be braced against sidesway.
406.2.5.1 The radius of gyration, r, shall be permitted to be calculated by (a), (b), or (c):
𝐼𝑔
a. 𝑟 = √𝐴 (406.2.5.1)
𝑔
b. 0.3 times the dimension in the direction stability is being considered for rectangular
columns;
c. 0.25 times the diameter of circular columns.
406.2.5.2 For composite columns, the radius of gyration r, shall not be taken greater than:
𝐸𝑐 𝐼𝑔
( )𝐸𝑠 𝐼𝑠𝑥
5
𝑟=√ 𝐸𝑐 𝐴𝑔 (406.2.5.2)
( )𝐸𝑠 𝐴𝑠𝑥
5
Longitudinal bars located within a concrete core encased by structural steel or within transverse
reinforcement surrounding a structural steel core shall be permitted to be used in calculating 𝐴𝑠𝑥
or 𝐼𝑠𝑥 .
406.2.6 Unless slenderness effects are neglected as permitted by Section 406.2.5, the
design of columns, restraining beams, and other supporting members shall be based on the
factored forces and moments considering second order effects in accordance with Section
406.6.4, 406.7, or 406.8. 𝑀𝑢 including second-order effects shall not exceed 1.4𝑀𝑢 due to first
order effects.
Table 406.3.2.1: Dimensional Limits for Effective Overhanging Flange Width for T-Beams
Flange Location Effective Overhanging Flange Width, beyond face of web
8ℎ
𝑠𝑤
Each Side of Web Least of: ⁄2
𝑙𝑛⁄
8
6ℎ
𝑠𝑤
One Side of Web Least of: ⁄2
𝑙𝑛⁄
12
406.3.2.2 Isolated non-prestressed T-beams in which the flange is used to provide additional
compression area shall have a flange thickness greater than or equal to 𝟎. 𝟓𝒃𝒘 and an effective
flange width less than or equal to 𝟒𝒃𝒘 .
406.3.2.3 For prestressed T-beams, it shall be permitted to use the geometry provided by
Sections 406.3.2.1 and 406.3.2.2.
406.4.2 For one-way slabs and beams, it shall be permitted to assume (a) and (b):
a. Maximum positive 𝑴𝒖 near midspan occurs with factored 𝑳 on the span and on alternate
spans;
b. Maximum negative 𝑴𝒖 at support occurs with factored 𝑳 on adjacent spans only.
406.4.3 For two-way slab systems, factored moments shall be calculated in accordance
with Section 406.4.3.1, 406.4.3.2, or 406.4.3.3, and shall be at least the moments resulting from
factored 𝑳 applied simultaneously to all panels.
406.4.3.1 If the arrangement of 𝑳 is known, the slab system shall be analyzed for that
arrangement.
406.4.3.2 If 𝑳 is variable and does not exceed 𝟎. 𝟕𝟓𝑫, or the nature of 𝑳 is such that all
panels will be loaded simultaneously, it shall be permitted to assume that maximum 𝑴𝒖 at all
sections occurs with factored 𝑳 applied simultaneously to all panels.
406.4.3.3 For loading conditions other than those defined in Section 406.4.3.1 or 406.4.3.2,
it shall be permitted to assume (a) and (b):
a. Maximum positive 𝑴𝒖 near midspan of panel occurs with 75% of factored 𝑳 on the
panel and alternate panels;
b. Maximum negative 𝑴𝒖 at a support occurs with 75% of factored 𝑳 on adjacent panels
only.
406.5.2 𝑴𝒖 due to gravity loads shall be calculated in accordance with Table 406.5.2.
Table 406.5.2 Approximate Moments for Non-Prestressed Continuous Beams and One-
Way Slabs
Moment Location Condition 𝑴𝒖
End Span Discontinuous end integral with 𝑤𝑢 𝑙𝑛2⁄
support 14
2
Positive Discontinuous end unrestrained 𝑤𝑢 𝑙𝑛⁄
11
Interior Spans All 𝑤𝑢 𝑙𝑛2⁄
16
Interior face of Member built integrally with 2
𝑤𝑢 𝑙𝑛⁄
exterior supporting spandrel beam 24
support Member built integrally with 2
𝑤𝑢 𝑙𝑛⁄
supporting column 16
Exterior face Two spans 𝑤𝑢 𝑙𝑛2⁄
of first interior 9
support More than two spans 𝑤𝑢 𝑙𝑛2⁄
Negative 10
Face of other All 2
𝑤𝑢 𝑙𝑛⁄
supports 11
Face of all a) Slabs with spans not exceeding 3m.
supports b) Beams where ration of sum of 𝑤𝑢 𝑙𝑛2⁄
satisfying (a) column stiffnesses to beam stiffness 12
or (b) exceeds 8 at each end of span.
To calculate negative moments, 𝒍𝒏 shall be the average of the adjacent clear span lengths.
406.5.3 Moments calculated in accordance with Section 406.5.2 shall not be redistributed.
406.5.4 𝑽𝒖 due to gravity loads shall be calculated in accordance with Table 406.5.4.
Table 406.5.4 Approximate Shears for Non-Prestressed Continuous Beams and One-Way
Slabs
Location 𝑽𝒖
Exterior face of first interior support 1.15𝑤𝑢 𝑙𝑛⁄
2
Face of all other supports 𝑤𝑢 𝑙𝑛⁄
2
406.5.5 Floor or roof level moments shall be resisted by distributing the moment between
columns immediately above and below the given floor in proportion to the relative column
stiffnesses considering conditions of restraint.
Table 406.6.3.1.1(a) Moment of Inertia and Cross-Sectional Area Permitted for Elastic
Analysis at Factored Load Level
Cross-Sectional
Member and Condition Moment of Inertia
Area
Columns 0.7𝐼𝑔
Uncracked 0.7𝐼𝑔
Walls
Cracked 0.35𝐼𝑔 1.0𝐼𝑔
Beams 0.35𝐼𝑔
Flat Plates and Flat Slabs 0.25𝐼𝑔
Table 406.6.3.1.1 (b) Alternative Moments of Inertia for Elastic Analysis at Factored Load
Alternative Value of 𝑰 for Elastic Analysis
Member Minimum 𝑰 Maximum
𝐴𝑠𝑡 𝑀𝑢 𝑃𝑢
Columns and Walls 0.35𝐼𝑔 (0.8 + 25 ) (1 − − 0.5 ) 𝐼𝑔 0.875𝐼𝑔
𝐴𝑔 𝑃𝑢 ℎ 𝑃𝑜
Beams, Flat Plates, 𝑏𝑤
0.25𝐼𝑔 (0.1 + 25𝜌) (1.2 − 0.2 ) 𝐼𝑔 0.5𝐼𝑔
and Flat Slabs 𝑑
Note: For continuous flexural members, 𝑰 shall be permitted to be taken as the average of values obtained for the
critical positive and negative moment sections. 𝑷𝒖 and 𝑴𝒖 shall be calculated from the load combination under
consideration, or the combination of 𝑷𝒖 and 𝑴𝒖 that produces the least value of 𝑰.
406.6.3.1.2 For factored lateral load analysis, it shall be permitted to assume 𝑰 = 𝟎. 𝟓𝑰𝒈 for all
members or to calculate 𝑰 by a more detailed analysis, considering the reduced stiffness of all
members under the loading conditions.
406.6.3.1.3 For factored lateral load analysis of two-way slab systems without beams, which
are designated as part of the seismic-force-resisting system, 𝑰 for slab members shall be defined
by a model that is in substantial agreement with results of comprehensive tests and analysis and 𝑰
of other frame members shall be in accordance with Sections 406.6.3.1.1 and 406.6.3.1.2.
406.6.3.2 Service Load Analysis
406.6.3.2.1 Immediate and time-dependent deflections due to gravity loads shall be calculated
in accordance with Section 424.2.