Check Valves
Check Valves
Inline, right angle, manifold mounted, and pilot operated designs
Vickers inline, right-angle, and manifold Pilot operated valves, like direct
mounted check valves are direct operated valves, permit free flow in one
operated and used in hydraulic circuits direction and prevent flow in the reverse
to allow the free flow of fluid in one direction. However, pilot operated valves
direction only. The graphical symbol for permit reverse flow when a pilot
these valves is a spring-loaded ball and pressure signal is applied to the valve’s
a seat, as shown below. pilot port. The graphical symbol for
these valves is shown below. Pilot
operated valves have very low internal
Direct operated leakage and are typically used to lock a
cylinder in place until the main
directional valve shifts.
Pilot
A light spring holds the valve poppet in
its normally closed position. The valve
starts to pass fluid at a pressure
equivalent to the spring cracking In Out
pressure level. Various spring
(cracking) pressures are available to
suit aplication requirements.
Note: Vickers also has a range of SAE
All except inline models can be used for flange mounted check valves, and ISO
high velocity flows resulting in shock 4401-03 and -05 stackable check
conditions. Inline models are designed valves. Flange mounted models are
for low shock service.Inline check valves described in publication 627. Size -03
can be used as and -05 stackable models are described
a safety bypass for flow surges in publications GB-C-2027 and
through filters and heat exchangers. GB-C-2022, respectively.
With a higher spring rating, they can
also be used as a means of generating
pilot pressure.
2
Table of Contents
Model Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Ratings and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Pressure Drop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Installation Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Typical Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Model Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Ratings and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Installation Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Model Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Ratings and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Pressure Drop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Installation Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Model Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Pilot Area and Cylinder Ratios . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Ratings and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Installation Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Hydraulic Fluids
Seals
Mounting Position
Port Connections
Fluid Cleanliness
Ordering
Service Information
3
Inline Check Valves
Model Code
D*8P1 - ** - ** - 1*
1 2 3 4
3 Cracking Pressure
5 – 0,35 bar (5 psi)
30 – 2,0 bar (30 psi)
65 – 4,5 bar (65 psi)
Pressure Drop
Pressure Drop Across
D*8P1-**-5-1* Models
Pressure drop –psi
30 2,1
20 D*8P1-06 1,4
D*8P1-10
D*8P1-03
10 0,7
10 20 30 40 50 USgpm
45 90 135 180 l/min
Flow rate
4
Installation Dimensions
Millimeters (Inches)
CAUTION:
Do not use this valve to check a high
velocity reverse flow resulting in shock
conditions. (See typical applications
below.) Where such conditions exist,
Free Flow Vickers C2-8** or C5G-8** type check
valve should be used.
A B
Inlet connection. Outlet connection.
“S” straight threads or “S” straight threads or
“T” NPTF pipe threads “T” NPTF pipe threads
“T” NPTF
Model Series A B “S” Straight Thread Pipe Thd.
DT8P1-02 57,2 (2.25) 22,4 (0.88) – 1/4
D*8P1-03 76,2 (3.00) 25,4 (1.00) .7500-16 UNF-2B 3/8
DT8P1-06 98,6 (3.88) 38,1 (1.50) 1.0625-12 UNF-2B 3/4
DS8P1-06 104,0 (4.09) 38,1 (1.50) 1.0625-12 UNF-2B 3/4
D*8P1-10 134,4 (5.25) 63,5 (2.50) 1.6250-12 UNF-2B 1-1/4
Typical Applications
D*8P1 Inline Check Valve Can Be Used
Reciprocating motion with over-running
loads, either direction
High inertia
Heat exchanger reversing load
Tank
D*8P1 inline check valve, free flow Delivery-
from pump
D*8P1 inline check valve,
free flow
Directional valve
To hydraulic system Delivery-
from pump
Tank
Pressure adjustment
Free flow
Delivery-
from pump
Unloading relief valve Pump
Discharge to tank
5
Right Angle Check Valves
Model Code
C 2 (S) - 8 ** - (***)
1 2 3 4 5 6
Solid plug
(Can be drilled
to suit orifice
requirement)
Construction of
“S12” Cracking
Pressures Model
6
Installation Dimensions
Millimeters (Inches)
A
C
Inlet port.
“S” straight thread or Outlet port.
“P” NPTF pipe thread “S” straight thread or
C
“P” NPTF pipe thread
7
Manifold Mounted Check Valves
Model Code
(F3) - C 5 G - 8 ** - (**)
1 2 3 4 5 6
5 Nominal Size
805 – 3/8” pipe or 1/2” tube
815 – 3/4” pipe or 3/4” tube
825 – 1-1/4” pipe or 1-1/4” tube
Pressure Drop
Pressure Drop for Free Flow Across 1. Figures in the chart at left give approximate pressure drops ( P) when pasing
Check Valve 21 cSt (100 SUS) fluid having .865 specific gravity.
2. For any other viscosity, pressure drop (P1) will be:
Model Flow Rate P
Series l/min (USgpm) bar (psi) Viscosities – cSt (SUS) 14 32 43 54 65 76 86
(75) (150) (200) (250) (300) (350) (400)
18,9 (5) 0,9 (13)
% of P (Approximate) 93 111 119 126 132 137 141
37,8 (10) 1,2 (17)
C5G-805 3. For any other specific gravity (G1), pressure drop (P1) will be approximately:
56,8 (15) 1,5 (22)
75,7 (20) 1,9 (27) P1 = P (G1/G). (Obtain specific gravity figure from fluid producer; figure will
be higher for fire-resistant fluids than for oil.)
37,8 (10) 0,5 (7)
75,7 (20) 1,0 (15)
C5G-815
113,6 (30) 1.7 (25)
151,4 (40) 2,4 (35)
94,6 (25) 0,6 (8)
189,3 (50) 0,8 (12)
C5G-825 283,9 (75) 1,1 (16)
378,5 (100) 1,5 (22)
473,2 (125) 2,1 (30)
8
Installation Dimensions – C5G-805 Series
Millimeters (Inches)
Example:
One (1) C5G-805 Check Valve 33,3
One (1) BKCG-805-619 Bolt Kit (1.31)
65 (2.56)
Inlet port
Mounting surface 47,7 (1.88) 12,7 (.50)
R 8,6 (.34)
77,7
(3.06)
7,92
(.312) 60,4
hex. (2.38)
Outlet port
O 10,72 (.422) thru
O 17,5 (.69) spotface
4 holes for mounting
9
Installation Dimensions – C5G-815 and C5G-825 Series
Millimeters (Inches)
O 6,4 (.25) 2 places
6,4
Mounting Bolt Kits (.25)
Mounting bolts must be ordered separately.
Radius V OS
Outlet connection A N
N P
Inlet connection
A
Direction of P U
oil flow
R
R M
B
B
L Q
L
OW
C Radius V
O 7,14 (.281). 7,8 (.31) deep.
Mounting surface O H thru. J counterbore - K deep. 2 holes (For rest pins)
(Seals furnished) 4 holes for mounting (NOTE: J is
spotface for C5G-825)
Model
Series A B C D E F G H J K
C5G-815 96,8 112,8 76,2 11,2 41,1 50,8 38,1 16,66 25,4 15,7
(3.81) (4.44) (3.00) (.44) (1.62) (2.00) (1.50) (.656) (1.000) (.62)
C5G-825 127 127 110,2 10,4 47,7 66,5 57,9 19,84 30 –
(5.00) (5.00) (4.34) (.41) (1.88) (2.62) (2.28) (.781) (1.18)
Model
Series L M N P Q R S T U V W
C5G-815 81 40,4 65 32,5 68,3 22,3 23,01 .625-11 8,6 15,7 23.01
(3.19) (1.59) (2.56) (1.28) (2.69) (.88) (.906) UNC-2B (.34) (.62) (.906)
C5G-825 91,9 46 91,9 46 71,4 20,6 34,92 .750--10 9,6 17,5 28,6
(3.62) (1.81) (3.62) (1.81) (2.81) (.81) (1.375) UNC-2B (.38) (.69) (1.125)
10
Pilot Operated Check Valves
Model Code
(F3) - 4C * - ** - (D) * - 2*
1 2 3 4 5 6 7
Pilot Area and With large check valves or large in a “through” hole in the pilot-piston
differential-area cylinders, the valve’s end of the main poppet. The
Cylinder Ratios ratio may be difficult to acieve. For decompression poppet opens first,
The ratio between a check valve’s pilot these cases, a decompression-type reducing the pressure behind the main
pressue area and poppet area must be check valve, which can have an poppet that is holding the main poppet
greater than the ratio between a opening ratio of 30:1 or greater, can closed. When this pressure is low
hydraulic cylinder’s piston and annulus be used . enough, the pilot piston pushes the
areas. If it is not, the valve will not open main poppet into the “open” position to
to permit reverse flow. For example, if A decompression poppet (within the allow full reverse flow.
the cylinder has a piston-to-annulus main poppet) is much smaller than the
area ratio of 2:1, the valve must have a check valve’s pilot piston and is seated
greater (3:1) ratio.
11
Installation Dimensions – 4CG Series
Millimeters (inches)
Radius J
E E C
A
D D
O 10,31 (.406) thru. 15,09 (.594) counterbore
Free flow inlet or reversed controlled to depth shown. H holes (See mounting pad
flow outlet (Use gage conn. number 2) dimensions for spacing)
Approx.
Model Weight
Series A C D E F G H J AB kg (lb)
4CG-03 68,1 36,6 43,7 28,4 39,6 122,2 4 10,4 55,9 3,6
(2.68) (1.44) (1.72) (1.12) (1.56) (4.81) (.41) (2.20) (8)
4CG-06 78,5 41,4 50,8 35 55,6 171,7 4 11,2 68,6 6,8
(3.09) (1.63) (2.00) (1.38) (2.19) (6.76) (.44) (2.70) (15)
4CG-10 100,1 50,8 58,7 47,7 54,9 193,5 6 10,4 90,2 11,8
(3.94) (2.00) (2.31) (1.88) (2.16) (7.62) (.41) (3.55) (26)
12
Installation Dimensions
Subplates and Bolt Kits for 4CG Valves
Millimeters (inches)
Port
not
Radius W used
O 7,14 (.281). 7,9 (.31)
deep. For rest pin O FF - 2 holes
.5625-18 UNF-2B thread Radius S - 2 places
(from reverse side)
** RXGM–03 and -06 use 4 valve mounting bolts. RXGM-10 uses 6 bolts.
Subplate Tube
Model K O. D. L M N P R S T U V W X Y Z
RXGM-03S--20 .7500-16 1/2” 25,4 19 63,5 127 76,2 23,9 43,7 87,4 63,5 10,4 35,8 42,9 25.4
UNF-2B (1.00) (.75) (2.50) (5.00) (3.00) (.94) (1.72) (3.44) (2.50) (.41) (1.41) (1.69) (1.00)
RXGM-06SX-20 1.3125-12 1” 31,7 19 73,1 146 117,3 39,6 50,8 101,6 82,5 11,2 49,3 60,4 33,3
UN-2B (1.25) (.75) (2.88) (5.75) (4.62) (1.56) (2.00) (4.00) (3.25) (.44) (1.94) (2.38) (1.31)
RXGM-10S-30 1.6250-12 1-1/4” 47,7 22,3 79,2 158,7 146 47,7 58,7 117,3 104,6 10,4 67,6 84,1 44,4
UN-2B (1.88) (.88) (3.12) (6.25) (5.75) (1.88) (2.31) (4.62) (4.12) (.41) (2.66) (3.31) (1.75)
Approx. NFPA
Subplate Weight Inter-
Model AA BB CC DD EE FF GG HH JJ ** KK LL MM PP RR kg (lb) face
RXGM- 33,3 66,5 4 53,1 106,4 14,2 21,3 28,4 – 31,7 4,8 38,1 6,3 10,4 1,5 P03
03S-20 (1.31) (2.62) (2.09) (4.19) (.56) (.84) (1.12) (1.25) (.19) (1.50) (.25) (.41) (3.25)
RXGM- 39,6 79,2 4 62 123,9 23,1 20,6 38,1 – 44,4 6,3 53,8 17,5 11,2 2,9 P06
06SX-20 (1.56) (3.12) (2.44) (4.88) (.91) (.81) (1.50) (1.75) (.25) (2.12) (.69) (.44) (6.50)
RXGM- 48,5 96,8 6 69,1 138,2 28,4 24,6 50,8 42,2 62,7 7,9 76,2 20,6 10,4 5 P10
10S-30 (1.91) (3.81) (2.72) (5.44) (1.12) (.97) (2.00) (1.66) (2.47) (.31) (3.00) (.81) (.41) (11)
13
Installation Dimensions – 4CS and 4CT Series
Millimeters (Inches)
P sq.
K
L
R wrench flats
O Q - 3 places 3 places
N
M
F
A
System connections.
S or T thread. 3 places
Pressure gage
Free Flow conn. number 1.
J Outlet .4375-20 UNF str. thd.
Optional-
Free Flow or for 1/4” O. D. tubing
Free Flow
Inlet Inlet
or or E Reversed B
Controlled
Reversed Reversed Flow Inlet
Controlled Controlled (Use gage Pressure gage
Flow Outlet Flow Outlet conn. no. 1) conn. number 2.
(Use gage C .4375-20 UNF str. thd.
conn. no. 2) for 1/4” O. D. tubing
H
Pilot control
connection
D .5625-18 UNF-2B
A
Model
Series A B C D E H J K L
4C*-03 57,1 24,1 45,2 28,4 23,1 53,1 122,2 69,8 39,6
(2.25) (.95) (1.78) (1.12) (.91) (2.09) (4.81) 2.75 1.56
4C*-06 70,1 31,7 57,1 35 26,9 74,7 171,4 88,6 50,8
(2.76) (1.25) (2.25) (1.38) (1.06) (2.94) (6.75) (3.49) (2.00)
4C*-10 95,2 29,2 77,8 47,7 28,9 84,1 193,8 117,8 68,3
(3.75) (1.15) (3.10) (1.88) (1.14) (3.31) (7.63) 4.64 2.69
14
Application Data, Ordering, and Service
.
15