Você está na página 1de 115

210 South 3rd Street  North Wales, PA 19454 USA 1 Modular Product Solutions . . .

Your Link to Mission Success


Table of Contents

I. Corporate History & General Overview


II. Core Technologies
III. AL4304 Communications Multiplexer Overview & Specifications
IV. AL4304 Chassis Operation
A. Chassis Components
B. Overview of Each Module
1. OC3CIF
2. MUX9
3. DEMUX9
4. AUD4
5. HVA1
6. ASYNC2
C. Software Overview and Remote Control Functionality
V. Apogee Labs - Contact Information

210 South 3rd Street  North Wales, PA 19454 USA 2 Modular Product Solutions . . . Your Link to Mission Success
Corporate History & Overview

• Founded in 1993

• Privately owned, small business

• NASA’s multiplexing techniques are the foundation


on which our mux/demux systems were developed

• Product line has evolved to include a wide range of data acquisition, data
distribution/transport, testing, and specialty engineered products for the
telemetry & communication communities

• Customer list includes domestic and international government and


military agencies as well as the world’s largest defense contractors

210 South 3rd Street  North Wales, PA 19454 USA 3 Modular Product Solutions . . . Your Link to Mission Success
Core Technologies
Solutions for Your Telemetry Needs

Multiplexers/Demultiplexers Testers

Digital Matrix Switches Displays

TMoIP Interfacers

210 South 3rd Street  North Wales, PA 19454 USA 4 Modular Product Solutions . . . Your Link to Mission Success
Model 4304 Communications Multiplexer

The AL4304 Communications MUX is a modular chassis that

provides the platform for a wide variety of multiplexing interfaces.

210 South 3rd Street  North Wales, PA 19454 USA 5 Modular Product Solutions . . . Your Link to Mission Success
Model 4304 Communications Multiplexer

Product Features:
• 3U chassis
• 14 card locations available for interface modules
• Redundant power supplies
• LCD Front panel display and Keyboard for local control
• Touch screen LCD display
• Remote control via Ethernet

210 South 3rd Street  North Wales, PA 19454 USA 6 Modular Product Solutions . . . Your Link to Mission Success
Model 4304 Communications Multiplexer

Specifications
5 ¼” High x 19” Wide x 15.8” Deep Chassis
• 14 slots (Populated with user modules)

7 inch color LCD display


• Touch-screen and keypad controls

Pluggable main and redundant supply – 150 Watts each


• Power Switch located on supplies at rear of unit

Front Panel LED power indicator (green/red)


• Main Supply
• Redundant Supply

Ethernet Remote Control


• AL4304 Server Based
• APEX (local PC hosted)

210 South 3rd Street  North Wales, PA 19454 USA 7 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Functional Block Diagram

Setup, Control, and Status


FRONT PANEL
PROCESSOR
AL4304 Server
Based
Touch-screen
LCD
NETWORK APEX
DISPLAY
Key Pad CONTROL BUS
CUSTOM
CONTROL S/W

M M
O O
D D
U U
L Slots 0 to 13 L
E E

210 South 3rd Street  North Wales, PA 19454 USA 8 Modular Product Solutions . . . Your Link to Mission Success
AL4304 System Block Diagram

Multiplexing
Multiplexing is a method by which multiple signals or data streams are
combined into one signal and transported over a shared medium.

PCM MUX9

Audio AUD4
OC3CIF OC3 (fiber)
Video HVA1

Asynchronous ASYNC2

210 South 3rd Street  North Wales, PA 19454 USA 9 Modular Product Solutions . . . Your Link to Mission Success
AL4304 System Block Diagram

Demultiplexing
Demultiplexing is the opposite of multiplexing. It is a method by
which multiple signals or data streams are extracted from one signal
and restored to their original medium.

DEMUX9 PCM

AUD4 Audio
OC3 (fiber) OC3CIF
HVA1 Video

ASYNC2 Asynchronous

210 South 3rd Street  North Wales, PA 19454 USA 10 Modular Product Solutions . . . Your Link to Mission Success
AL4304 System Block Diagram

Combining Multiplexing and Demultiplexing


Combining Multiplexing and Demultiplexing allows for the transport of
multiple data streams across a single fiber optic link.

PCM PCM
Audio OC3 Audio
AL4304 AL4304
Video (fiber) Video
Asynchronous Asynchronous

This is how the AL4304 transports data

210 South 3rd Street  North Wales, PA 19454 USA 11 Modular Product Solutions . . . Your Link to Mission Success
AL4304 System Block Diagram

Apogee Labs Multiplexing concepts


Bandwidth

PCM PCM
Audio OC3 Audio
AL4304 AL4304
Video (fiber) Video
Asynchronous Asynchronous

The OC3 link bandwidth must be greater that the sum of all the
channel’s bandwidth and associated overhead

PCM Rate + Audio Rate + Video Rate + Async Rate + overhead must be
less than the OC3CIF user transport rate

210 South 3rd Street  North Wales, PA 19454 USA 12 Modular Product Solutions . . . Your Link to Mission Success
AL4304 System Block Diagram

Apogee Labs Multiplexing concepts


System Timing

PCM PCM
Audio OC3 Audio
AL4304 AL4304
Video (fiber) Video
Asynchronous Asynchronous

• The OC3IF polls the interface modules for data at a set sample interval
• This interval is called the SI
• The SI can be set to 1 ms or 10 ms
• After receiving the SI signal, each module transfers its accumulated
data to the OC3CIF module based upon slot location (slot 0 first etc.)

210 South 3rd Street  North Wales, PA 19454 USA 13 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Operation

Main Components

Beyond housing user modules, the AL4304 chassis has three main
components that allow for proper operation of the system.

• Power Supply (with switch)

• Front Panel GUI (with keypad)

• Network interface

210 South 3rd Street  North Wales, PA 19454 USA 14 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Operation

Main Components Chassis


Power Supply Module PS01-AC

210 South 3rd Street  North Wales, PA 19454 USA 15 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Operation

Main Components Chassis


Power Supply Module PS01-AC

• AL4304 chassis holds two PS01-AC modules


• AL4304 chassis has two dedicated slot locations for the PS01-AC
modules (slot 14 and 15)
• Redundant
• Power load sharing
• Independent power switch for each module
• Status LED on each module to indicate supply is in regulation
• Front panel status on GUI for each module
• Front panel LED for chassis Power

210 South 3rd Street  North Wales, PA 19454 USA 16 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Operation

Main Components Chassis


Power Supply Module PS01-AC

• General Specifications of PS01-AC modules


• 150 Watt Supplies (each)
• Switching power supplies
• 100-240 V input (AC)
• 90-260 Hz frequency input
• IEC connector for power input

210 South 3rd Street  North Wales, PA 19454 USA 17 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Operation

Main Components Chassis


Power Supply Module (PS01-AC)

How to install and power on module

1. Do not handle module with power cord plugged in


2. Make sure that power supply switch is in the off position
3. If needed, remove blank panel for power supply on chassis
4. Slide module into chassis on slide rails
5. Firmly press into backplane
6. Screw in the four retention screws
7. Plug in AC power into IEC connector
8. Turn on power switch

210 South 3rd Street  North Wales, PA 19454 USA 18 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Operation

Main Components Chassis


Power Supply Module (PS01-AC)

How to power down and remove module

1. Turn off power switch


2. Remove AC power cord from IEC connector
3. Unscrew the four retention screws
4. Press down ejector handle until module releases from backplane
5. Slide module out of chassis
6. If needed, replace blank panel onto AL4304 chassis

210 South 3rd Street  North Wales, PA 19454 USA 19 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Operation

Main Components Chassis


Front Panel Graphical User Interface (GUI) and keypad

• AL4304 chassis has 7” front panel


• Touch screen and keypad control
• System configuration and Status
• Ethernet Setup, Firmware Upgrades, System Status
• Module configuration and status
• Defined by module
• Status Signals per module (slot)
• User definable triggers

210 South 3rd Street  North Wales, PA 19454 USA 20 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Operation

Main Components Chassis


Front Panel Graphical User Interface (GUI)
AL4304 chassis front panel touch-screen control

Two types of fields


1. Configuration
2. Status

210 South 3rd Street  North Wales, PA 19454 USA 21 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Operation

Main Components Chassis


Front Panel GUI
AL4304 chassis front panel touch-screen control

Configuration
• Press field with stylus/finger to engage in field
• For fields with set menu, select desired option
• For fields with numeric input use keypad to
Clear field, enter desired value, press enter

210 South 3rd Street  North Wales, PA 19454 USA 22 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Operation

Main Components Chassis


Front Panel GUI
AL4304 chassis front panel touch-screen control

Status
• Status fields will, by default, display associated status
• These fields cannot be configured

210 South 3rd Street  North Wales, PA 19454 USA 23 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Operation

Main Components Chassis


Front Panel Keypad control

The keypad is used for:

• Navigation between modules

• Navigation within modules

• configuration of modules

210 South 3rd Street  North Wales, PA 19454 USA 24 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Operation

Main Components Chassis


Front Panel GUI

How to edit a field - Drop down list


These fields have an pull-down arrow on the right side of the field

Configuration
• Press field with stylus/finger
• An option list will pop up
• Press desired value
Value will be accepted
Configuration for that field is done

210 South 3rd Street  North Wales, PA 19454 USA 25 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Operation

Main Components Chassis


Front Panel GUI

How to edit a field – decimal/HEX input


These fields don’t have a pull-down arrow on the field

Configuration
• Press field with stylus/finger
• On keypad, press the clear button to clear field
• On keypad, type the numeric/HEX value
• On keypad, press the Enter button
Value will be accepted
Configuration for that field is done

210 South 3rd Street  North Wales, PA 19454 USA 26 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Operation

Main Components Chassis


Front Panel GUI

Fields for the chassis and each module will be discussed as the
Training continues

210 South 3rd Street  North Wales, PA 19454 USA 27 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Operation

Main Components Chassis


Remote Control

The AL4304 has an Ethernet port for system configuration and status

• Standard RJ45 connector

• 10/100/1000 interface

• Auto-detect for crossover cabling

210 South 3rd Street  North Wales, PA 19454 USA 28 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Operation

Main Components Chassis


Remote Control

There are four methods for Ethernet control on the AL4304


• Secure Web Server
• HTTPS
• Internet Explorer 6+, Firefox 4+ supported
• SSH and Telnet client
• Reference manual for all Telnet instruction sets
• Custom GUI developed by user
• Based on SSH and Telnet client
• APEX
• OS independent (Tested on Windows XP/7, Linux)

All four methods can provide similar functionality with access


to the most configuration and status information

210 South 3rd Street  North Wales, PA 19454 USA 29 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Operation

Main Components Chassis


Remote Control

AL4304 secure web server

• Apogee Labs integrated GUI

• HTTPS for secure connection

• GUI mimics front panel controls

• Allows configuration of status indicators on top of display

210 South 3rd Street  North Wales, PA 19454 USA 30 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Operation

Main Components Chassis


Remote Control
AL4304 secure web server – Login Screen

210 South 3rd Street  North Wales, PA 19454 USA 31 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Operation

Main Components Chassis


Remote Control
AL4304 secure web server – System screen

210 South 3rd Street  North Wales, PA 19454 USA 32 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Operation

Main Components Chassis


Remote Control
AL4304 secure web server – MUX9-1 screen

210 South 3rd Street  North Wales, PA 19454 USA 33 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Operation

Main Components Chassis


Remote Control

APEX

• Apogee Labs Developed Software package

• Hosted on PC

• Provides simple interface to AL4304 to user

• Compatible with Windows XP/7 and Linux

210 South 3rd Street  North Wales, PA 19454 USA 34 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Operation

Main Components Chassis


Remote Control
APEX – Log-in and system screen

210 South 3rd Street  North Wales, PA 19454 USA 35 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Operation

Main Components Chassis


Remote Control
APEX – MUX9 control screen

210 South 3rd Street  North Wales, PA 19454 USA 36 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Operation

Main Components Chassis


Remote Control

AL4304 Custom Interface (User developed)

• Developed by user

• Builds on AL4304 SSH and Telnet Client

• Refer to manual for commands

210 South 3rd Street  North Wales, PA 19454 USA 37 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules
OC3CIF
• Fiber-optic transmitter/receiver for AL4304 MUX/DEMUX system
MUX9
• PCM interface for multiplexer
DEMUX9
• PCM interface for demultiplexer
AUD4
• Four channel audio interface for multiplexer and demultiplexer
HVA1
• Video interface for multiplexer or demultiplexer
ASYNC2
• Four channel async interface for multiplexer and demultiplexer

210 South 3rd Street  North Wales, PA 19454 USA 38 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – OC3CIF (2041)

The OC3CIF module provides an interface that is compatible with a


standard telco OC3 network
• OC3 Packetizer / Depacketizer
• Fiber-optic transmitter/receiver for AL4304 MUX/DEMUX system
• Integrates Multiplexer and Demultiplexer on single module
• Packetizes data for multiplexing
• Depacketizes data for demultiplexing
• Provides up to 122 Mbps of user bandwidth on both TX and RX
• Compatible with OC3 concentrator/switch
• Single mode ST fiber optic connector

210 South 3rd Street  North Wales, PA 19454 USA 39 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – OC3CIF (2041)


Connections

• Single mode fiber from one chassis TX to another chassis RX

210 South 3rd Street  North Wales, PA 19454 USA 40 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – OC3CIF (2041)


Configuration / Settings

210 South 3rd Street  North Wales, PA 19454 USA 41 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – OC3CIF (2041)


Configuration / Settings – XPORT Rate

Range: 1 Mbps to 122 Mbps


• Bandwidth on OC3 line reserved for multiplexed user data. This
should be set to 122 for point-to-point fiber links. If transmitting to a
concatenator it should be set above needed bandwidth

210 South 3rd Street  North Wales, PA 19454 USA 42 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – OC3CIF (2041)


Configuration / Settings – Bandwidth Used

Value 1% to 100%

• Percent of available OC3 bandwidth taken up by user data. This is the

XPORT rate divided by 122 Mbps.

210 South 3rd Street  North Wales, PA 19454 USA 43 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – OC3CIF (2041)


Configuration / Settings - VPATHID

Range: 0x01 to 0xFF

• Virtual Path ID. A hexadecimal value that would be used if connecting

to an external ATM switch/concatonator for routing the signal. If on a

point-to-point fiber link, this is not used.

210 South 3rd Street  North Wales, PA 19454 USA 44 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – OC3CIF (2041)


Configuration / Settings – SI SOURCE

Values: LOCAL, RMT

• Establishes the source of the system sample timing. This should be

set to LOCAL.

210 South 3rd Street  North Wales, PA 19454 USA 45 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – OC3CIF (2041)


Configuration / Settings – SI Period

Values: 1 ms, 10 ms
• This determines the system sample rate of the chassis for the data it is
transmitting
• 1 ms is recommended to minimize latency
• 10 ms is recommended to maximize bandwidth

210 South 3rd Street  North Wales, PA 19454 USA 46 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – OC3CIF (2041)


Configuration / Settings - LINK

Values: OK, LOS


• Indicates the status of the optical input signal
• OK indicates that optical power is seen on the input
• LOS indicates that there is no optical input power found

210 South 3rd Street  North Wales, PA 19454 USA 47 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – OC3CIF (2041)


Configuration / Settings - SYNC

Values: LOCK, SERCH, HW ERR


• Indicates the status if the input demultiplexing circuitry
• LOCK indicated that the OC3CIF has locked to the incoming data
• SEARCH indicates that the OC3CIF is not able to lock to the incoming
data
• HW ERR indicates that the communication between the processor and
hardware has been lost.
Contact customer support

210 South 3rd Street  North Wales, PA 19454 USA 48 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – OC3CIF (2041)


Configuration / Settings - Overflow

Values: NONE, PACK, DEPAK


• Indicates an overflow condition on the packetizer or depacketizer
• NONE indicates no loss due to bandwidth limitations
• PACK indicates that the packetizer has too much data to transport
• DEPAK indicates that the depacketizer is receiving too much data to
ingest to the demultipexing modules

210 South 3rd Street  North Wales, PA 19454 USA 49 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – OC3CIF (2041)


Configuration / Settings – Sequence Errors

Range: 0 to 65,535
• Indicates the number of count errors in the received data. This should
not increment if the link is running error free.
• If this counter is incrementing, it indicates that errors are being
received by the depacketizer from the fiber link

210 South 3rd Street  North Wales, PA 19454 USA 50 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – OC3CIF (2041)


Configuration / Settings – CRC Errors

Range: 0 to 65,535
• Indicates the number of CRC errors in the received data. This
should not increment if the link is running error free.
• If this counter is incrementing, it indicates that errors are being
received by the depacketizer from the fiber link

210 South 3rd Street  North Wales, PA 19454 USA 51 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – OC3CIF (2041)


Configuration / Settings – Clear Button

• When pressed, the Sequence Errors and CRC Errors fields will
reset to 0

210 South 3rd Street  North Wales, PA 19454 USA 52 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – MUX9-1 (2416)


PCM (RS-422) dual channel input module
• Two pairs of data/clock input to multiplex into the AL4304 MUX system
• For each of the two channels
• Operates rate
• 1 kbps to 40 Mbps (10 ms SI)
• 3.5 kbps to 40 Mbps (1 ms SI)
• Triax connectors for data and clock signals
• Center pin positive (+) signal
• Middle ring negative (-) signal
• Shell ground
• 120 Ohm termination across + and – input
• Packetizes data for multiplexing at SI rate
• Separate Channel IDs for independent routing

• Module data compatible with DEMUX9 output modules

210 South 3rd Street  North Wales, PA 19454 USA 53 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – MUX9-1 (2416)


Connections
• Two independent pairs of data/clock inputs supported

210 South 3rd Street  North Wales, PA 19454 USA 54 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – MUX9-1 (2416)


Configuration / Settings

210 South 3rd Street  North Wales, PA 19454 USA 55 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – MUX9-1 (2416)


Configuration / Settings – CH1 / CH2

Values: Enabled, Disabled


• Enables or Disables the input channel to the Multiplexer
• Enabled allows that channel to deliver its data to the multiplexing
module (OC3CIF)
• Disabled prevents the channel from delivering its data to the
multiplexing module (OC3CIF)

210 South 3rd Street  North Wales, PA 19454 USA 56 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – MUX9-1 (2416)


Configuration / Settings – CH1 ID / CH2 ID

Range 0x000 to 0x7FF


• Sets the channel ID for the channel
• Places a tag on this channel’s data packets that allows it to be
identified by a demultiplexing module to recreate the data
• All Channel IDs must be unique on the multiplexing side

210 South 3rd Street  North Wales, PA 19454 USA 57 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – MUX9-1 (2416)


Configuration / Settings – Rate1 / Rate2

Range 0 to 40000000
• Displays the measured input clock for the channel

210 South 3rd Street  North Wales, PA 19454 USA 58 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – MUX9-1 (2416)


Configuration / Settings – Status 1 / Status 2

Values: Active, Idle, HwERR


• Displays the module status for the channel
• Active indicates that the channel is receiving a clock on its input
• Idle means that the channel is not receiving a clock on its input
• HwERR means that the software is not able to communicate with the
module’s firmware. Contact customer support

210 South 3rd Street  North Wales, PA 19454 USA 59 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – DEMUX9-1 (2417)


PCM (RS-422) dual channel output module
• Two pairs of data/clock output demultiplexed from the AL4304 system
• For each of the two channels
• Operates rate
• 1 kbps to 40 Mbps (10 ms SI)
• 3.5 kbps to 40 Mbps (1 ms SI)
• Triax connectors for data and clock signals
• Center pin positive (+) signal
• Middle ring negative (-) signal
• Shell ground
• Drives 100-120 Ohm termination across + and – input
• Independent Channel IDs

• Module data compatible with MUX9 input module

210 South 3rd Street  North Wales, PA 19454 USA 60 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – DEMUX9-1 (2417)


Connections
• Two independent pairs of data/clock inputs supported

210 South 3rd Street  North Wales, PA 19454 USA 61 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – DEMUX9-1 (2417)


Configuration / Settings

210 South 3rd Street  North Wales, PA 19454 USA 62 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – DEMUX9-1 (2417)


Configuration / Settings – CH1 ID / CH2 ID

Range 0x000 to 0x7FF


• Sets the channel ID for the channel
• This configures the channel to capture data from a multiplexed
channel with the same channel ID
• Multiple Demux channels/modules can be set to the same channel ID
for a multicast-type application

210 South 3rd Street  North Wales, PA 19454 USA 63 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – DEMUX9-1 (2417)


Configuration / Settings – Rate1 / Rate2

Range 0 to 40000000
• Displays the rate of the data that the Channel ID is capturing,
reconstructing, and outputting on its connector.

210 South 3rd Street  North Wales, PA 19454 USA 64 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – DEMUX9-1 (2417)


Configuration / Settings – Status1 / Status2

Values: Active, Idle, HwERR


• Displays the channel status
• Active indicates the module is reconstructing data
• Idle indicates that the channel does not recognize a data source at its
configured Channel ID
• HwErr indicates that the module’s firmware cannot communicate with
the modules firmware
Contact customer support

210 South 3rd Street  North Wales, PA 19454 USA 65 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – ASYNC2 (2109)


Asynchronous four channel input/output module
• Bi-directional module
• Four sets of asynchronous data multiplexed to the AL4304
• All four asynchronous channels embedded in same channel ID
• Four sets of asynchronous data demultiplexed from the AL4304
• For each of the four channels
• BAUD rate 1200 to 115200 (standard rates)
• Parity Odd, Even, None
• Interface for RS-232, RS-422, RS-485 configurations
• Two DB-9 connectors (two channels on each)
• See manual for pin out

• Module interfaces with another ASYNC2 to complete


multiplexing/demultiplexing path

210 South 3rd Street  North Wales, PA 19454 USA 66 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – ASYNC2 (2109)


Connections
• Four pairs of bidirectional asynchronous data are supported

210 South 3rd Street  North Wales, PA 19454 USA 67 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – ASYNC2 (2109)


Status / Settings

The ASYNC2 module has three


screens that are switched between
using the F1, F2, and F3 keys to the
right of the display

210 South 3rd Street  North Wales, PA 19454 USA 68 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – ASYNC2 (2109)


Status / Settings – TX CHID

Range: 0x000 0x7FF


• Sets the transmit channel ID for the module
• Places a tag on this module’s data that allows it to be identified by a
demultiplexing module to recreate the data
• All Channel IDs must be unique on the multiplexing side
• All four asynchronous channel’s data are embedded into a single
packet using a single TX CHID

210 South 3rd Street  North Wales, PA 19454 USA 69 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – ASYNC2 (2109)


Status / Settings – RX CHID

Range: 0x000 0x7FF


• Sets the receive channel ID for the module
• This configures the module to capture data from a channel with the
same channel ID

210 South 3rd Street  North Wales, PA 19454 USA 70 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – ASYNC2 (2109)


Status / Settings – PA Status, PB Status, PC Status, PD Status

Values: Active, Idle


• Provides activity status for the ports (PA = Port A etc.)
• Idle means that there is no data passing in either direction on the port
• Active means that data is seen on the port
• This is the same as the Status n field on the Setup screens

210 South 3rd Street  North Wales, PA 19454 USA 71 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – ASYNC2 (2109)


Status / Settings - Status A/B, Status C/D

Values: OFF, 1200 – 115200 (standard BAUD rates)


• Configures the BAUD rate for the channel
• This is the BAUD rate for the data it is receiving from the local
equipment
• OFF disables this input channel on the module

210 South 3rd Street  North Wales, PA 19454 USA 72 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – ASYNC2 (2109)


Status / Settings - Rmt BAUD A / Rmt BAUD B / Rmt BAUD C / Rmt BAUD D

Values: OFF, 1200 – 115200 (standard BAUD rates)


• On the Demultiplexing side, this is the BUAD rate of the data that is
being received on that channel
• The local channel will output data at this BAUD rate.
• OFF means that the remote channel is disabled

210 South 3rd Street  North Wales, PA 19454 USA 73 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – ASYNC2 (2109)


Status / Settings – Par A / Par B / Par C / Par D

Values: ODD, EVEN, NONE


• On the multiplexing side, parity for this input channel
• This should be set to match the local equipment sending data into this
channel of the ASYNC2 module

210 South 3rd Street  North Wales, PA 19454 USA 74 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – ASYNC2 (2109)


Status / Settings – Rmt Par A / Rmt Par B / Rmt Par C / Rmt Par D

Values: ODD, EVEN, NONE


• On the demultiplexing side, parity for this output channel
• This is a status field that is established by the remote ASYNC2
• The local channel will output data with this parity

210 South 3rd Street  North Wales, PA 19454 USA 75 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – ASYNC2 (2109)


Status / Settings – IF A / IF B/ IF C / IF D

Values: RS232, RS422, RS485-2W, RS485-4W


• This field sets the electrical interface for this port
• Refer to user manual for information on the electrical interfaces
• Refer to user manual for connector pinot

210 South 3rd Street  North Wales, PA 19454 USA 76 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – ASYNC2 (2109)


Status / Settings – Status A / Status B / Status C / Status D

Values: Active, Idle


• This field provides status for the port
• Active means that data is seen on the port
• Idle means that there is no data passing in either direction on the port

210 South 3rd Street  North Wales, PA 19454 USA 77 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – HVA1 (2180)


MPEG video (H.264) and audio input/output module

• Configurable as Video Input or Video output module

• Operates in NTSC or PAL

• Configurable data rates (200 kbps to 8 Mbps)

• Configurable frame rate (1 to 30 fps)

• Module interfaces with another HVA1

• One set as encoder and one set as decoder

210 South 3rd Street  North Wales, PA 19454 USA 78 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – HVA1 (2180)


Connections

• One set of video/audio data is supported

210 South 3rd Street  North Wales, PA 19454 USA 79 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – HVA1 (2180)


Configuration / Settings

210 South 3rd Street  North Wales, PA 19454 USA 80 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – HVA1 (2180)


Configuration / Settings - Mode

Values: Disabled, Encode, Decode


• Disabled means that the module is not running
• Encode means that the module set to encode the video and audio on
its Video In and Audio In connectors
• Decode means that the module is set to decode video and audio on its
Video Out and Audio Out connectors

210 South 3rd Street  North Wales, PA 19454 USA 81 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – HVA1 (2180)


Configuration / Settings – Video Status

Values: Active, Idle, HW Err


• Active means that the module see a valid video signal and is
compressing or uncompressing the signal as the Mode indicates
• Idle means that the module does not recognize a valid video signal or
valid data
• HW Err indicates a fault in the hardware. Contact Apogee Labs
customer support

210 South 3rd Street  North Wales, PA 19454 USA 82 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – HVA1 (2180)


Configuration / Settings – Total Bit Rate

Range: 0 to 10000 Kbps


• Indicates the Total Bit Rate used by the compressed video and audio
• Total Bit Rate will be greater than encoder Bit Rate due to the audio
bandwidth and transport overhead

210 South 3rd Street  North Wales, PA 19454 USA 83 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – HVA1 (2180)


Configuration / Settings – Enc ID

Range: 0x000 to 0x7FF


• When in Encode Mode, This is the channel ID of the packets getting
multiplexed and sent to the demultiplexer

210 South 3rd Street  North Wales, PA 19454 USA 84 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – HVA1 (2180)


Configuration / Settings – Enc Std

Values: NTSC, PAL


• When in Encode Mode, This is the Video Standard that the compression
engine is trying to synchronize to
• This must be set to match the video source on the Video In connector

210 South 3rd Street  North Wales, PA 19454 USA 85 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – HVA1 (2180)


Configuration / Settings – Frame Rate

Values: 1, 2, 3, 5, 6, 10, 12.5, 15, 25, 30


• When in Encode Mode, sets the frames per seconds that the
compression engine is compressing
• Configuring the Frame Rate allows the user to strike a balance
between image quality, bandwidth, and motion detection

210 South 3rd Street  North Wales, PA 19454 USA 86 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – HVA1 (2180)


Configuration / Settings – Bit Rate

Range: 200 to 8000 kbps


• When in Encode Mode, this sets the target bit rate for the compressed
video
• This value does not account for bandwidth from the audio or
compression overhead (refer to Total Bit Rate)

210 South 3rd Street  North Wales, PA 19454 USA 87 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – HVA1 (2180)


Configuration / Settings – Audio

Value: Enabled, Disabled


• When in Encode Mode, this determines is the audio input signal is
compressed and sent in the module’s packet
• Enabled includes the audio in the module’s packetized data
• Disabled does not include the audio in the module’s packetized data

210 South 3rd Street  North Wales, PA 19454 USA 88 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – HVA1 (2180)


Configuration / Settings – Dec Id

Range: 0x000 to 0x7FF


• When in Decode Mode, This sets the ID of the packet that the decoder
is attempting to recover video and audio from
• Multiple HVA1 modules can be set to the same Dec Id value to form a
multicast-type implementation

210 South 3rd Street  North Wales, PA 19454 USA 89 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – HVA1 (2180)


Configuration / Settings - Dec Std

\Values: NTSC, PAL


• When in Decode Mode, This sets the video standard that the module
will be outputting on the Video Out connector
• This must be set to match the video standard of the encoder module
that the module is recovering video and audio from

210 South 3rd Street  North Wales, PA 19454 USA 90 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules – AUD4 (2053)

Four channel audio input/output module


• Bi-directional module
• Operates as an audio input and audio output module
• All four TX channels can be enabled/disabled
• RX audio can listen to up to 6 remote AUD4 TX audio channels
• Module interfaces with another AUD4 module
• Line level inputs and outputs (2.2V pk-pk)
• 32 kbps bandwidth per channel
• RJ-45 connectors (one for each channel)
• Reference user manual for RJ45 pinot

210 South 3rd Street  North Wales, PA 19454 USA 91 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules –AUD4 (2053)


Configuration / Settings / Status

The AUD4 module has three screens


that are switched between using the
F1, F2, and F3 keys to the right of
the display

210 South 3rd Street  North Wales, PA 19454 USA 92 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules –AUD4 (2053)


Configuration / Settings / Status - TXID

Range: 0x00 to 0xFF


This is the base channel ID for the module. The value is padded with a
leading 0x0 to create the full channel ID
• Setting the TXID to 0x00 disables the module

210 South 3rd Street  North Wales, PA 19454 USA 93 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules –AUD4 (2053)


Configuration / Settings / Status - #TXCH

Range: 0 - 4
• This sets the number of active channels in the module
• If less than all four channels are enabled, the number of channels
enabled starts with the first channel
Example: If #TXCH = 3, channels 1, 2, and 3 are enabled

210 South 3rd Street  North Wales, PA 19454 USA 94 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules –AUD4 (2053)


Configuration / Settings – CH1 Mode / CH2 Mode / CH3 Mode / CH4 Mode

Values: Normal, Test,


• This configures each input channel to run in Normal or Test mode
• Normal mode encodes audio from audio input and embeds that data
into the modules data packet
• Test mode encodes a test tone that is slot and channel dependent
• Refer to user manual for frequencies of test tones

210 South 3rd Street  North Wales, PA 19454 USA 95 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules –AUD4 (2053)


Configuration / Settings – C1A-C1F / C2A-C2F / C3A-C3f / C4A-C4F

Range: 0x000 – 0x4FF


• This defined which AUD4 multiplexed channels are output on each
AUD4 output channel
• Each channel can listen to up to six audio sources
• 0x000 configures that input as null
• Format is: 0xABB
• A is source channel (1 – 4)
• B is source module’s TXID

210 South 3rd Street  North Wales, PA 19454 USA 96 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Modules

Modules –AUD4 (2053)


Configuration / Status – 1A-1F / 2A-2F / 3A-3f / 4A-4F

Values: Q, S, X
• This defines the status of the audio sources
• Each audio output can monitor up to six audio sources
• Q means that the source the input is set to is not found
• S means that the source the input is set to is found
• X means that the there is no source set for that input
• Decoder is set to 0x0

210 South 3rd Street  North Wales, PA 19454 USA 97 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Software

Remote Control
HTTPS interface

• Open compatible web browser on same network


• Type the AL4304 chassis’ IP-address in address bar
• Press enter button

210 South 3rd Street  North Wales, PA 19454 USA 98 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Software

Remote Control
HTTPS interface

• Type in username and password


• Press Submit button

210 South 3rd Street  North Wales, PA 19454 USA 99 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Software

Remote Control
HTTPS interface

• The Left column is the list of modules

210 South 3rd Street  North Wales, PA 19454 USA 100 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Software

Remote Control
HTTPS interface

• The center of the page is the current module screen


• Default on startup is the AL4304 system page

210 South 3rd Street  North Wales, PA 19454 USA 101 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Software

Remote Control
HTTPS interface

• The top of the page is the status LEDs


• The configuration for the status LEDs are on the module pages

210 South 3rd Street  North Wales, PA 19454 USA 102 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Software

Remote Control
HTTPS interface

• Move to a modules page by pressing the name on the left

210 South 3rd Street  North Wales, PA 19454 USA 103 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Software

Remote Control
HTTPS interface – module page

• Module screen contains the same field as in the APEX and font panel GUI

210 South 3rd Street  North Wales, PA 19454 USA 104 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Software

Remote Control
HTTPS interface - module page

• In the top right of the screen is the link to change the LED thresholds
• This determines what changes a modules LED from red to green
• The HTTPS interface is the only way to edit the LED thresholds

210 South 3rd Street  North Wales, PA 19454 USA 105 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Software

Remote Control
HTTPS interface – module thresholds

• The options for configuring the thresholds can be selected


• When the conditions are met, the LED for that slot will turn green
• When the conditions are not met, the LED for that slot will turn red

210 South 3rd Street  North Wales, PA 19454 USA 106 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Software

Remote Control
HTTPS interface

• To logout of the HTTPS interface, press the log out link on the top right

210 South 3rd Street  North Wales, PA 19454 USA 107 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Software

Remote Control
APEX – Setup

• Run application

210 South 3rd Street  North Wales, PA 19454 USA 108 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Software

Remote Control
APEX – Setup

• On “Welcome to APEX” screen


• Press: Setup → Add Node

210 South 3rd Street  North Wales, PA 19454 USA 109 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Software

Remote Control
APEX – Setup

On “Add Node pop-up” window

• Select AL4304

• Press “OK”

210 South 3rd Street  North Wales, PA 19454 USA 110 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Software
Remote Control
APEX – Setup

Configure top section to allow communications with chassis


• Enter IP-address and port from Al4304 chassis
• Verify Telnet is enabled on AL4304
• Enter in Username and Password
• Press Connect
210 South 3rd Street  North Wales, PA 19454 USA 111 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Software

Remote Control
APEX – Setup

• Once Connected press “Get Slot Configuration”


• Chassis modules should populate on left side window
• Press “Finish Edit”

210 South 3rd Street  North Wales, PA 19454 USA 112 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Software

Remote Control
APEX – Log-in and system screen

You are connected now


• Press module in left column to bring up that module

210 South 3rd Street  North Wales, PA 19454 USA 113 Modular Product Solutions . . . Your Link to Mission Success
AL4304 Chassis Software

Remote Control
APEX – Log-in and system screen

The module page will now display


• The module has the same fields as previously described
• Edit with keyboard

210 South 3rd Street  North Wales, PA 19454 USA 114 Modular Product Solutions . . . Your Link to Mission Success
Contact Information

210 S. Third Street ● North Wales, PA 19454 USA

Robert W. Weaver Jr.


Applications Engineer
(T) 011-215-699-2060 Ext. 315
(C) 011-215-436-7850
(E) bob.weaver@apogeelabs.com

SETEX DIVISÃO AERO ESPACIAL


São José dos Campos – SP – Brazil
Sergio Vale / Lucia Castro
Email: sergiovale@setex.com.br / luciacastro@setex.com.br
Telephone: +55 (12) 3917-1267 | FAX: +55 (12) 3341-3755 |
Cellular: +55 (12) 9745-3656
Skype: Lucia_Castro_Souz

210 South 3rd Street  North Wales, PA 19454 USA Modular Product Solutions . . . Your Link to Mission Success