Você está na página 1de 29

S Saudi Fan Industries

High Efficiency Radial Fans


Type: ERAE / ERAD

With forward curved impellers


S Saudi Fan Industries

Management Commitment To Quality


We are continuously striving to provide higher quality products and
services to achieve total customer satisfaction by understanding
their requirements and anticipating their future expectations or
needs.

We are committed to development and strengthening of partnership


with our external and internal customers and suppliers.

We are dedicated to the continual improvement of all products and


services through involvement of all employees.

We value all people by understanding and drawing upon their


strengths i.e. abilities and knowledge and make efforts for their
training and development.

President

Ali Saleh Al-Khalaf


..
Table of Contents
Management commitment to quality 1

.. Company profile
General technical information
2
3

.. Fan introduction
Fan performance curves
6
8

.. Accessories
Guide to fan selection &typical application
21
24

. Call for tender / warranty


Contacts / inquiries
25
26

Company Profile
Saudi Fan Industries was established in 1999 as another manufacturing division of steadily
growing organization " Refrigeration House Group" in order to fulfill requirements of local market
for air movement and control equipments.
As a member of Refrigeration House Group, that has market research for ventilation equipments
spread over 25 years, Saudi Fan Industries now has grown into a full swing manufacturing unit to
satisfy the demanding needs of air movement and control equipments for modern residential,
commercial and industrial zones.

Since its establishment, Saudi Fan Industries has acquired modern manufacturing technology in
order to achieve " Total Customer Satisfaction". Not only still it has been investing significant
resources in latest technology but also has created a medium where every one in the organization
can contribute. We have a stringent policy of research, development and making awareness of
technology throughout the organization. Saudi Fan Industries has been implementing ISO 9002
Quality Assurance System. As a result, Saudi Fan Industries’ products are manufactured precisely
and consistently through all production stages under strict quality control procedures.
Saudi Fan Industries strictly acting on the policy of " the high quality product should be delivered
to our valued customers right from the beginning".

Now Saudi Fan Industries is not only the leading supplier of air movement and control equipments
in Kingdom but also a famous name in entire Gulf. It offers a wide range of fans and ventilator
products for residential, commercial, institutional and industrial buildings in applications from
comfort ventilation to manufacturing processes.
Products are available for exhaust, supply, re-circulate, filtered, process and gravity applications.
Fans are available in either direct drive, or belt drive.
Saudi Fan Industries has significant production capacity in order to fulfill market's demand. It also
has a pool of qualified staff, who are fully dedicated to give best advice to our valued customer's
inquiries.

Saudi Fan Industries has technical collaboration with Rosenberg Ventilator GmbH. Who is a Certified
ISO 9001 manufacturer and its products are listed under following ratings:

OUR SISTER CERTIFIED


ORGANIZATION RATINGS

R
General Technical Information

Saudi Fans Distinguished Features


Saudi Fan Industries ' fans are equipped with direct driven Insulation Class
external rotor motors, which have decisive advantages over The windings of single inlet fans comply with insulation class B,
conventional fans:
the windings of double inlet fans comply with insulation class F.
Long Service Life In addition the windings have a standard moisture impregnation.
Compact design
The speed is 100% controllable through Thermal Protection
auto transformer or electronic control. All external rotor motors except the explosion-proof motors are
Low starting currents. equipped with thermal contacts, embedded in the windings to
protect the motor. Thermal contacts are bi-metallic cutouts,
Advantages of our single phase type fans.
We recommend the use of single phase fans (E), whenever temperature dependent, When properly wired they protect
possible, which offer the following advantages: against overload, main-phase failure, stalling of motor and too
high ambient temperatures.
Two or five cores plus earth cable only. Always correct Motor protection is guaranteed, when the thermal contacts are
direction of rotation. wired through a tip contactor circuit.
Motor protection through built-in thermal overload contacts,
In connection with thermal contacts we recommend to fit our
wired in series with the motor winding.
Low cost speed controllers with 5 steps or electronic control, supplied controllers for better motor protection.
available ex-stock. For the exhaust of explosive mixture in temperature classes
T1 to T3 in Zone 1 and 2, we offer fans with specific controllable
External rotor motors motors in protection class "e", for intrinsically safe application,
The external rotor motor drive offers features such as space
according to DIN 50019.
saving, compact and attractive design.
The motor is fitted within the impeller, which enables the best
possible cooling. For this reason a 100% variable speed Electrical connection
control can be guaranteed. V-belts, additional tension bars Electrical connection will be made by an enclosed terminal box,
and motor mountings are not necessary. protection class IP 44. As special execution we are able to deliver
Only over-dimensioned ball-bearings (German products), terminal box made of aluminum protection class IP 55.
fitted on both side, sealed for life, are used. Both ball-bearing
seats are ground to high precision in one work process to
eliminate any vibrations. Selection of Fans
The following must be considered when selecting a suitable fan;
External rotor motors have extremely low starting Desired air volume and pressure loss
currents. Possible sizes
Sound characteristics
The motors comply with protection class IP44 according to DIN
40050. Protection class IP 54 for double inlet fans is available Ambient conditions
on request. Electrical power supply and tolerances

For the determination of the required air volume, any existing


External rotor motor construction resistance must be considered, which determine the operating
point. These losses could be from ducts and filters in front of or
Stator
behind the fan, air diffusers, heating and cooling elements and
Labyrinth ducts bends.

Rotor These resistence vary at the square of the air volume and can be
described in a specific characteristics curve.

Ball bearing Ambient operating temperature


Maximum ambient operating temperature can be taken from the
data sheets. Should the temperature indicated not be sufficient,
the possible temperature can be increased by using a larger motor
(at extra expenses).
High Efficiency Direct-Driven Radial Fans
With forward curved radial impellers ERAE / ERAD

Advantages: Electrical connection


The standard series is according to R20 and are in accordance to DIN 323 The motors are fitted with flying lead. The electrical connection
The outlet flange is in accordance to DIN 24 155 p.2 as well as DIN 24 159,p.3
can be made via an IP44 terminal box, which is supplied loose.
The speed is 0- 100% infinitely variable through auto transformers or
electronic control
Compact and space saving design Direction of rotation
Easy installation in any position Direction of rotation for fan types ERA is clockwise viewed from
Easy air volume adjustments via a large range of control products based on the inlet side.
pressure and temperature
Motor protection through thermal contacts in motor windings
Extremely low starting currents Noise levels
The figures in the air performance curves quoted in circles are
Application: the “A” decibel figures which are the sound
The high efficiency radial fans have been developed especially power levels LWA4,at the outlet side in duct systems.
for modern ventilation and air conditioning applications
General ventilation of commercial premises.
Slightly dusty and greasy air, Slightly aggressive gases and fumes The “A” sound power level at the inlet side LWA5 according to
(please refer to our engineers). DIN 45 635, part 38, is obtained as follows:
Mediums up to an atmospheric density of 1,2 kg/m3 .
Mediums passing though with a temperature of LWA5 = LWA4 2 dB(A)
- 30 °C up to + 70 °C and mediums up to a max. Humidity of 95% The “A” sound pressure level LPA at a distance of 1 meter is
obtained approximately by deducting 7 dB(A) from the
Ranges
Models : 22 models for each single inlet / double inlet “A” sound power level.
Motors : 4, 6 and 8 pole depending on whether single or
three phase version. It is important to note that the reflection and room characteristic
Flow Rate : up to 4,000 CFM as well as natural frequencies differently influence the sound
up to 7,000 m3/h pressure levels.
Construction
Casing The octave sound power level is important for the choice of suitable
The casing of the high efficiency radial fans is made of galvanized sound attenuator. It is obtained as follows.
sheet steel and the side parts of the scroll is assembled with the
spirally shaped guide plate through a standing seam. Lwoct = LWA4 + Lwrel
The side parts are produced with nut sets to fix the mounting The relative octave sound power level Lwrel at octave medium
brackets, which can be fixed in steps of 90°.
frequency can be taken from the following table:
Impellers
The impeller is made of galvanized sheet metal, and is mounted
directly to the rotor of external rotor motor and is balanced at two fm [Hz] 63 125 250 500 1000 2000 4000 8000
levels together with the rotor according to G 2,5 to DIN/ISO 1940. Lwrel at V= 0.5 x Vmax
Lwrel [dB] 6 0 -2 -3 -3 -10 -16 -25
Remark
Lwrel at V= 0.8 x Vmax
Double inlet on request
Lwrel [dB] 5 -1 -2 -2 -4 -9 -16 -26

Reference Code
D
E R A E 225 -4 K
E single inlet

R radial fan

A external rotor motor

E single phase A.C ; D=three phase

impeller diameter

number of poles

K smaller motor
Fan Performance Curves

The performance curves for these fan types have been established in mounting position B (installed on the pressure
side and open on the suction side) and show the total pressure increase pt as a function of the volume flow.
The dynamic pressure pd2 refers to the flange cross-section at the outlet side of the fan. The performance curves refer
to an air density of 1.2 kg/m3.

ERAE 250-4

ERAE 250-4
230 V 60 Hz 1.5
1.0 kW IP 44
4.5 A 01.024
1460 min-1 19 kg
16 uF RE/RTE 5.0
50 RSE 5.5
220 Pa ED 5.0
2 MSE 1

: 02/2002
Accessories

SPEED CONTROL (for single phase)


Reducing Speed for fan
Speed Controls are available in various models for different applications up to 10 Amps, this speed controller requires
50x100 handy box and its circuit is illustrated on the drawing below for (single phase motors).

Speed control (for three phase)


ACCESSORIES
SPEED CONTROL (for single phase)
ACCESSORIES
SPEED CONTROL (for Three phase)
Guide for specification

Fan (Blower assembly) shall be as manufactured by Saudi Fan Industries, Saudi Arabia and shall be complete with a
High Efficiency Radial Fan type: ERAE / ERAD with either 50Hz or60 Hz external rotor motor suitable for 127V or 220V-1Ph
or 220V/380V-3 Phase power supply where required.

Type ERAE /ERAD (Single width Single Inlet SWSI)

The complete fan shall be assembled using a compact combination of external rotor motor close coupled to a forward curve
impeller to realize best possible cooling. The external rotor motor shall have a minimum of IP 44 construction per DIN 40050;
the windings` insulation shall have class “B” construction with additional protection against moisture; each external rotor motor
shall be 100% compatible ordinary electronic speed controller by varying speed from 100% to 10% of rated speed
(Note : For 3 phase external rotor motors other methods of motor speed control variable speed driver or multi-tap step down
transformers should be availab le).
Each motor shall have a built-in thermal overload protection.
The casing shall be made from galvanized steel sheets or painted with an epoxy paint against corrosion protection.
The impeller shall be forward curve type and shall be made of galvanized steel.
Both impeller & external rotor motor shall be balanced at 2 levels as per DIN/ISO 1940 G 2.5.
Each fan shall be equipped in to an IP 44 terminal box with a wiring diagram.
Fan shall be UL & AMCA listed.

Typical application

ROOF CAP

EXHAUST AIR SUPPLY AIR


FLOW FLOW

FILTER & BOX

SUPPLY AIR
FLOW
For contacts & inquiry Refrigeration House Group

.
P.O.Box.1823 - Al-Khobar.31952
SAUDI ARABIA

Head Office
Tel:(03) 882 1713 - 882 3515 Fax: (03)882 3066

. Manufacturing Divisions
Dammam 2nd Industrial City
National Factory Tel:(03) 812 1282 Fax: (03) 812 1848
Saudi Fan Industries Tel:(03) 812 1866 Fax: (03) 812 1894

. Contracting Division
Klimatechnik Tel: (03) 882 3534 Fax: (03) 882 2807
Riyadh Tel: (01) 465 6198 Fax: (01) 462 8347

. Trading Divisions
Refrigeration House
Al-Khobar Tel: (03) 869 1043 Fax: (03) 898 4161
Jubail Tel: (03) 361 5512 Fax: (03) 361 279
Riyadh Tel: (01) 476 9720 Fax: (01) 476 9518
Jeddah Tel: (02) 665 2276 Fax: (02) 661 2265

. Bahrain Regional Office


Tel.:++973 537784 Fax:++973 537138
Klimatechnik
Al-Hassa

Al-Yaf Ind.
MODERN iNDS.C0. Abha Street
PETROL STATION

(TIDE)
S

NOTIONAL
FACTORY Saudi Fan Inds.
ABQAIQ HIGHWAY

Eastern heaters. Gasket factory

Saudi Inds.
Al-Hamarani. Solvrnt C0.

N
-MOO
Dam

HALF ACH
BE
amm

MAIN ENTRANCE
2ND INDS. CITY
DAMMAM
S Saudi Fan Industries

High Efficiency Radial Fans

High Efficiency Radial Fans High Efficiency Radial Fans Duct Fans

Axial Fans AND-Axial Fans Zero-Box

Tube Fans Roof Fans MUS Fans

Silent Fans Twin Fans Blower Fans

Você também pode gostar