Liquid Pumps
Liquid Pumps
AIR DRIVEN FROM 60 PSI TO 60,000 PSI
Maximator high efficiency pumps are ideal for a broad variety of oil,
water and chemical applications. They feature a large air piston joined to
a smaller diameter plunger. The pressure ratio is the difference of these two areas
and is the method of determining maximum output pressure. Higher pressures are
obtained by using higher pressure ratios. Maximator model numbers reflect the
pump’s nominal pressure ratios, while the technical data indicates exact ratios.
Maximator hydraulic pumps cycle automatically. The pump stops
automatically when the output pressure forces and the air drive forces are equal.
The pump restarts with a slight drop in the outlet pressure or an increase in the air
drive pressure.
Pump performance can be affected by a number of conditions, such
as freezing of mufflers or pilot valves (which is caused by moisture in air lines),
inadequate inlet air line sizes and dirty filters.
Please consult MAXPRO for exact flow conditions not shown in charts.
MAXPRO offers complete technical and service support for all Maximator pumps.
Features
■ Easy to install and operate
Index Page
■ Standard ratios available for pressures to 60,000 psi
Applications 3 ■ Economical source for hydraulic power
How to Select a MAXPRO Pump 3 ■ Pressure maintained without energy consumption
■ Pilot air valve is unregulated for easy restart and better pressure
How a Liquid Pump Works 4-5
control range on S-D, LO and L series pumps
Oil or Oil/Water Service ■ Requires no lubrication
PPO Series 6-7 ■ Explosion proof...no electrical power required
S Series 8 ■ External spool valve for faster and easier maintenance, standard
S-D Series 9 on all but PPO series
LO Series 10 ■ Outlet pressure can be preset by use of simple optional air regulator
Water or Oil Service
PP Series 11-12 Models/Options
PP-HL Series 13 ■ Stainless steel construction on most PP and all L and
L Series 14-16 GX series pumps
GX Series 17 ■ Distance piece pumps available in PPSF, LSF and GX series
■ Double acting styles available on PPO, S, PP and L pumps
Chemical Service
■ Multiple air heads available on PP and L pumps
PPSF Series 18-19
■ Accessories available for all pumps
LSF Series 20-21
DC Series 22
CAUTION: While testing has shown O-rings to provide satisfactory service
Accessories 22 life, both cyclic and shelf life may vary widely with differing service conditions,
properties of reactants, pressure and temperature, and age of O-ring.
Packaged Systems 23 Frequent Inspection Should Be Made to detect any deterioration,
and O-rings replaced as required.
2
Applications
SERIES PPO, S, S-D and LO
The rugged construction, light weight ■ Lifting and Jacking – lifting tables, scissor jack lifts, beam
and wide range of pressure ratios make
■
jacking and aircraft jacking OIL or
these series of pumps ideal for powering Hydraulic Operation – clamping devices, punch and pin
a variety of oil/hydraulic operations. presses, grippers, chucks, valve actuation OIL/WATER
Pressures to 14,500 psi. ■ Presses – cold isostatic presses, filter presses, hydraulic MIXTURE
press actuation and system overload
■ Tooling and Tightening – actuating cropping, crimping, cable SERVICE
shears and pipe bending tools; bolt tensioning and torque wrenches PUMPS
■ Paper – roller tensioning, cutters/knives
■ Testing – hydrostatic pressure testing and tensile test machines
■ Miscellaneous – lubrication systems, trash compactors, truck bed
and trailer wheel cylinders, powering small transfer cylinders, extraction
of press fit gears and fittings, and replacement of hand pumps
2. Hydraulic Section
In this section, the hydraulic piston/plunger is attached to the air piston and
its bottom section is housed inside the hydraulic pump head. Its size determines
the pressure ratio of the pump, which in turn designates output flow and maximum
1. AIR DRIVEN SECTION pressure capability. Its purpose is to pull liquid into the hydraulic body through
the inlet check valve and push it out through the outlet check valve
at an elevated pressure.
These check valves are spring loaded and direct the passage of liquid
through the pump. During the suction stroke of the hydraulic piston/plunger, the
inlet check valve opens to its maximum. The liquid is pulled into the pump while
the outlet check valve is held shut by a spring and differential pressure. On the
pressure stroke, the inlet check valve is closed as the hydraulic piston/plunger
moves the liquid out through the outlet check valve.
A seal is positioned around the hydraulic piston/plunger and is one of a
few parts that may wear. The seal’s purpose is to hold the liquid under pressure
during cycling and to prevent both external leakage and leakage into the air drive.
Various seal materials and designs are utilized based on the liquid to be pumped,
operating temperature and pressure rating.
NOTE: With most pumps, a separation or distance piece may be utilized
between the air drive section and the hydraulic section. This allows for total
2. HYDRAULIC SECTION separation and contaminant-free operation.
3. Spool Valve
This section is comprised of an unbalanced, pilot operated, lightweight spool
which moves the compressed air to either side of the air piston, depending on
AIR position. The air piston moves pilot valves at the end of each stroke, alternately
INLET
➠
pressurizing and venting the large area of the spool, allowing it to control the air
flow to the air piston, providing automatic cycling. The main drive air is vented
through an exhaust muffler. On the larger pumps, an unregulated pilot air port is
used to overcome friction and differential pressures which enables excellent
3. SPOOL VALVE pressure control. This is also an ideal place to use any pump control devices.
4
MAXPRO air driven liquid pumps work on a standard reciprocating differential
AIR DRIVE
area principle utilizing a large air drive piston connected to a smaller hydraulic
piston/plunger to convert compressed air power into hydraulic power.
The nominal ratio between the area of the hydraulic plunger and the air drive PISTON
piston is shown by the dash number in the model description and estimates the
maximum pressure the pump is able to generate. The actual ratio can be higher
than the nominal so the pump will still cycle when the ratio of the output hydraulic PLUNGER
pressure to the air drive pressure equals the nominal ratio. Consult technical
information chart in the catalog for actual pressure ratios. Example: an S35 HYDRAULIC
PRESSURE
has an actual ratio of 1:39.
This means that the actual ratio of the area of the air piston is 39 times the area
of the plunger.
Example:
P.R. = Pressure ratio = 1:39
PA = Air drive pressure = 80 psi
PO = Maximum outlet pressure = 39 x 80 = 3,120 psi
If the air drive pressure is raised to 100 psi then the outlet pressure will be SINGLE AIR HEAD PUMP
near 3,900 psi at stall. The maximum air drive pressure rating on all pumps is 160 psi.
AIR
When drive air is initially introduced to the pump, the pump will cycle at
maximum speed, providing maximum flow and also functioning as a transfer
OUTLET
pump by filling the test piece or actuator with liquid. The pump will then begin to
cycle at a slower rate as the outlet pressure rises and offers more resistance to the
HYDRAULIC
reciprocating differential piston assembly. The piston assembly then stalls when
the forces balance, i.e. when air drive pressure x air drive piston area = outlet
INLET
(stall) pressure x driven hydraulic plunger area.
The hydraulic pressure drop (hysteresis) needed to cause the air driven pump
to restart is very low due to little frictional resistance from the large diameter air
drive piston seal and hydraulic seal. This can be as low as two times the pump’s
ratio under certain conditions.
The minimum air drive pressure to operate a pump is 15 psi and the
maximum is 145 psi depending on pump used.
5
OIL or OIL/WATER SERVICE
PPO
PPO pumps are lightweight and rugged making them ideal for portable power
packs and are available in eight pressure ratios as listed below. PPO pumps
are single acting, single air drive head types.
➠
NUMBER RATIO (PSI) (IN.3) INLET OUTLET (LBS.)
PUMP
HEAD PPO4 1:4 580 1.86 1 1⁄2
3 1
SUCTION PPO37 1:47 6,815 0.17 ⁄8 ⁄4
3 1
PPO72 1:88 12,760 0.09 ⁄8 ⁄4 7
3 1
PPO111 1:133 14,500 0.06 ⁄8 ⁄4
3 1
PPO189 1:225 14,500 0.04 ⁄8 ⁄4
NOTE: Air drive inlet connection on all PPO pumps is 1/4" FNPT.
All connections listed are FNPT unless otherwise noted.
Maximum allowable oil temperature is 140°F.
Air section temperature rating: 0°F to 140°F.
7.001 7.63
LIQUID
OUTLET
B
0.25
1.941 LIQUID
A INLET
2.31
1
NOTE: Mounting hole dimensions.
6 3.88
Dimensions are subject to change. Consult factory.
DIMENSIONS (inches) PPO22 - PPO189
3.13
1.941
AIR
INLET
0.13
1.19
3.38
1.56
0.31
PPO
SERIES
PRESSURES FROM
0.69
8.75 60 TO 14,500 PSI
5.681 6.31
OPTIONAL
SIDE INLET 7.56
0.311
DIA. 5.38 0.25
LIQUID
OUTLET 0.31
LIQUID
1.941 INLET
3.25 NOTE: 1
Mounting hole dimensions.
2.68 Dimensions are subject to change. Consult factory.
7
OIL or OIL/WATER SERVICE
S
SERIES
PRESSURES FROM
S pumps are compact and lightweight and are designed for simple installation
in both static and portable applications. Available in five pressure ratios, S pumps
are ideal for applications demanding fast response times.
AIR
TECHNICAL DATA
CYLINDER
WITH AIR
MAXIMUM DISPL.
CONNECTIONS
PISTON EXHAUST OUTLET PER
MUFFLER CATALOG PRESSURE PRESSURE CYCLE WEIGHT
NUMBER RATIO (PSI) (IN.3) INLET OUTLET (LBS.)
PUMP S15 1:17 2,465 1.73 3
⁄4 1⁄2
HEAD
➠
1
S25 1:25 3,625 1.20 ⁄2 1⁄ 2
➠
1 1
S35 1:39 5,655 0.77 ⁄2 ⁄2 20
1 1
SUCTION
S60 1:61 8,845 0.49 ⁄2 ⁄2
1 1
DISCHARGE S100 1:108 14,500 0.27 ⁄2 ⁄2
NOTE: Air drive inlet connection on all S pumps is 1/2" FNPT.
All connections listed are FNPT unless otherwise noted.
Maximum allowable oil temperature is 140°F.
Air section temperature rating: 0°F to 140°F.
DIMENSIONS (inches)
5.31 6.81
AIR INLET
0.25 3.41 2.62
CATALOG
NUMBER A B
7.62 7.81
S25, S35 6.06 3.00
S63, S100 7.81 4.06 LIQUID LIQUID
3/8 – 16 OUTLET INLET
MOUNTING 1.00
TAPS (2)
2.12 B
NOTE: Dimensions are subject to change. Consult factory. A
➠
3 HEAD
S15-D 1:16 2,320 3.45 ⁄4 1⁄2
➠
1
S25-D 1:24 3,480 2.39 ⁄2 1⁄ 2
1 1
S35-D 1:38 5,510 1.54 ⁄2 ⁄2 32 DISCHARGE
1 1
S60-D 1:60 8,700 0.98 ⁄2 ⁄2 SUCTION
1 1
S100-D 1:107 14,500 0.55 ⁄2 ⁄2
NOTE: Air drive inlet connection on all S-D pumps is 1/2" FNPT.
All connections listed are FNPT unless otherwise noted.
Maximum allowable oil temperature is 140°F. Air section temperature rating: 0°F to 140°F.
DIMENSIONS (inches) C
4.19
5.31 LIQUID 1.00
3.41 LIQUID
OUTLET INLET
AIR INLET
CATALOG
NUMBER A B C
LO
SERIES
PRESSURES FROM
LO
■
pumps are designed for rugged service with high flows. These pumps are
available in the single air drive head type with eight pressure ratios.
■ Carbon steel bodies and plungers and long service life
polyurethane seals.
LO pumps come standard with a bottom inlet. For a side inlet add – S.
■ Maximum air drive pressure 145 psi.
165 TO 14,500 PSI
■ Minimum air drive pressure 15 psi.
SPOOL PILOT TOP
VALVE CAP
■ For air control option ... add – ACP to catalog number.
VALVE
ON SIDE OF ■ All LO pumps come with an unregulated pilot port, 1/8" FNPT
TOP CAP
in the top cap. This feature provides more accurate pressure
AIR control and is an ideal location for control instrumentation.
CYLINDER
WITH
PISTON TECHNICAL DATA
AIR MAXIMUM DISPL.
CONNECTIONS
EXHAUST PUMP OUTLET PER
MUFFLER HEAD CATALOG PRESSURE PRESSURE CYCLE WEIGHT
NUMBER RATIO (PSI) (IN.3) INLET OUTLET (LBS.)
➠
DISCHARGE
LO10
LO15
1:11
1:16
1,595
2,320
4.57
3.17
1
1
1⁄2
1⁄ 2
1 1
LO25 1:28 4,060 1.80 ⁄2 ⁄2
➠
➠
add – HL to the catalog number. With the hand lever option, SUCTION
TECHNICAL DATA
Single Air Drive Head
MAXIMUM DISPL.
CONNECTIONS
OUTLET PER
CATALOG PRESSURE PRESSURE CYCLE WEIGHT
NUMBER RATIO (PSI) (IN.3) INLET OUTLET (LBS.)
PP4 1:4 580 1.86 1 1⁄2
3
PP8 1:9 1,305 0.90 ⁄4 1⁄ 2
3 1
PP12 1:14 2,030 0.57 ⁄4 ⁄2
3 1
PP22 1:28 4,060 0.28 ⁄8 ⁄4
3 1 7
PP37 1:46 6,670 0.17 ⁄8 ⁄4
3 1
PP72 1:86 12,470 0.09 ⁄8 ⁄4
3 1
PP111 1:130 15,000 0.06 ⁄8 ⁄4
3 9
PP189 1:220 31,900 0.04 ⁄8 ⁄16 –18
PP
SERIES
PRESSURES FROM
FLOW CHART and DIMENSIONS (inches)
3.13
1.941
0.75
0.31
0.62
4.63
4.00
3.13
0.31
60 TO 58,000 PSI
1.19
AIR
INLET
7.31
6.691
LIQUID
Single Air Drive Head OUTLET
B
CATALOG
NUMBER A B C 0.19
1
PP4 2.12 8.50 4.22 0.31
DIA.
C
PP8 1.88 8.25 3.94
PP12 1.88 8.25 3.94
1.941
LIQUID
3.19 INLET
A
4.75
1
NOTE: Mounting hole dimensions.
Dimensions are subject to change. Consult factory.
Single, Double and
Triple Air Drive Head 3.13 1.19
0.38 4.63
CATALOG 1.941
NUMBER A 0.38
4.00
0.75
AIR
SINGLE INLET SINGLE
1
AIR 7.06 6.31 4.63 AIR
HEAD 5.31 7.75 HEAD
9.00
0.19
LIQUID
OUTLET
1
.31 A
DIA.
1
NOTE: Mounting hole dimensions.
Dimensions are subject to change. Consult factory.
12
FLOW CHART — PP Series
SAMPLE
OUTLET PRESSURE (PSI)
AIR DRIVE
CATALOG PRESSURE
NUMBER (PSI) 0 500 1500 3000 5000 7500 10000 15000 25000 40000 55000
60 885
PP4 90 905
120 915 50
60 422 50
PP8 90 430 240
120 433 325
60 272 160
PP12 90 275 218
120 280 245 53
60 132 110 22 Above 35,000 psi
PP22 90 136 126 82 for intermittent
120 138 132 105 30 duty only
60 81 74 47
PP37 90 83 80 68 37
120 85 82 75 56 15
60 43 42 37 22 3
PP72 90 44 43 41 36 24 3
120 45 45 43 39 33 21 4
60 28 27 26 20 12 2
PP111 90 29 28 27 26 22 16 8
120 30 29 28 27 25 21 16 3
60 17 15 14 13 12 9 5
PP189 90 17 17 17 16 15 12 11 6
120 17 17 17 16 15 14 13 11 4
60 21 20 20 20 19 16 15 9
PP111-2 90 21 21 20 20 19 17 16 12
120 22 22 21 21 20 19 18 16 7
60 12 12 12 11 11 10 10 7 1
PP189-2 90 12 12 12 12 12 11 11 10 7
120 13 12 12 12 12 12 12 11 9 5 1
FLOW RATE IN CUBIC INCHES PER MINUTE. FLOW RATES SHOWN ARE FOR 1-10 CST FLUIDS.
MAXIMUM AIR CONSUMPTION FOR “PP” PUMPS: 20 SCFM @ 90 PSI (WITH 0 PSI OUTLET).
MAXIMUM AIR CONSUMPTION FOR “PP-2” PUMPS: 30 SCFM @ 90 PSI (WITH 0 PSI OUTLET).
PP-HL pumps are compact, lightweight and hand-operated. They are ideal
for precision pressurization in calibration of gauges and pressure transducers.
They also offer the ability to generate pressure when there is little or no air
pressure available.
■ PP-HL series pumps have stainless steel bodies and plungers
PP-HL
SERIES
PRESSURES FROM
0 TO 31,900 PSI
with polyurethane seals and Buna “N” O-rings.
■ PP-HL series pumps can be used with water or oil.
■ PP-HL series pumps can be wall mounted or ordered with a base
plate, ... add – BP to catalog number or for a one gallon stainless
steel reservoir, ... add – 1 G to the catalog number.
■ All PP-HL series pumps are standard with a bottom inlet.
For a side inlet, add – S.
TECHNICAL DATA
MAXIMUM DISPL.
CONNECTIONS
OUTLET PER
CATALOG PRESSURE STROKE WEIGHT
NUMBER (PSI) (IN.3) INLET OUTLET (LBS.)
3
PP22-HL 4,060 0.28 ⁄8 1⁄4
3
PP37-HL 6,670 0.17 ⁄8 1⁄ 4
3 1
PP72-HL 12,470 0.09 ⁄8 ⁄4 9
3 1
PP111-HL 15,000 0.06 ⁄8 ⁄4
3 9
PP189-HL 31,900 0.04 ⁄8 ⁄16 - 18
NOTE: All connections listed are FNPT unless otherwise noted.
The 9 /16" –18 is a 1/4" O.D. tubing, high pressure coned and threaded connection.
Maximum allowable oil/water temperature is 140°F.
13
WATER OR OIL SERVICE
L
SERIES
PRESSURES FROM
L pumps are available as single acting with either a single or
double air drive head and double acting with single air drive head.
■ L series pumps have stainless steel bodies and 17-4 plungers.
All L pumps have UHMWPE (Ultra High Molecular Weight
Polyethylene) seals and Viton2 O-rings (-VE).
■ L series pumps come standard with a bottom or side inlet.
165 TO 60,000 PSI For side inlet, add – S to catalog number.
■ Maximum air drive pressure 145 psi.
SPOOL VALVE ON TOP
SIDE OF TOP CAP CAP ■ Minimum air drive pressure 15 psi.
■ For air control option ... add – ACP to catalog number.
■ All L pumps come with an unregulated pilot port, 1/8" FNPT,
AIR
CYLINDER in the top cap. This feature provides more accurate pressure
WITH control and is an ideal location for control instrumentation.
PISTON
AIR ■ All L pumps are available with a double air drive head. This
EXHAUST
MUFFLER doubles the pressure ratio of the pump, allowing the use of a
PUMP
HEAD
➠ lower ratio base pump, to provide higher flow rates. It is also
used to achieve a given outlet pressure with less air drive
DISCHARGE pressure. Add – 2 to the catalog number.
➠
SUCTION
TECHNICAL DATA
Single Air Drive Head
TYPICAL L10-VE THROUGH MAXIMUM DISPL.
CONNECTIONS
L400-VE PUMPS OUTLET PER
CATALOG PRESSURE PRESSURE CYCLE WEIGHT
NUMBER RATIO (PSI) (IN.3) INLET OUTLET (LBS.)
SPOOL VALVE ON TOP
SIDE OF TOP CAP CAP L10-VE 1:11 1,595 5.49 1 1⁄2
36
L15-VE 1:16 2,320 3.78 1 1⁄ 2
1 1
L25-VE 1:28 4,060 2.15 ⁄2 ⁄2
AIR 1 1
32
CYLINDER L35-VE 1:40 5,800 1.49 ⁄2 ⁄2
AIR WITH L60-VE 1:63 9,135 0.94 1
⁄2 1
⁄2
EXHAUST PISTON
MUFFLER 1 1
L100-VE 1:113 15,000 0.54 ⁄2 ⁄2
1 9
L150-VE 1:151 21,025 0.40 ⁄2 ⁄16–18
1 9
L250-VE 1:265 38,425 0.23 ⁄2 ⁄16–18 30
➠
1 9
L300-VE 1:314 45,530 0.20 ⁄2 ⁄16–18
PUMP
HEAD 1 9
L400-VE 1:398 57,710 0.15 ⁄2 ⁄16–18
1 9
L500 1:591 60,000 0.12 ⁄2 ⁄16–18
DISCHARGE
➠
1 1
L25-2-VE 1:56 8,120 2.15 ⁄2 ⁄2
1 1
42
AIR L35-2-VE 1:80 11,600 1.49 ⁄2 ⁄2
CYLINDER 1 1
WITH L60-2-VE 1:126 15,000 0.94 ⁄2 ⁄2
AIR
EXHAUST PISTON L100-2-VE 1:226 30,450 0.54 1
⁄2 9
⁄16–18 40
MUFFLER 1 9
L150-2-VE 1:300 42,050 0.40 ⁄2 ⁄16–18
1 9
L250-2-VE 1:530 60,000 0.23 ⁄2 ⁄16–18
1 9
DRAIN L300-2-VE 1:628 60,000 0.20 ⁄2 ⁄16–18
PORT 1 9
49
L400-2-VE 1:796 60,000 0.15 ⁄2 ⁄16–18
➠
1 9
PUMP L500-2 1:1038 60,000 0.09 ⁄2 ⁄16–18
HEAD
NOTE: L500 pumps have polyurethane seals and BUNA-N O-rings
Air drive inlet connection on all L pumps is 1/2" FNPT.
➠
—
B
8.25
C
5.06
D
6.88
E
7.81 —
F
L
SERIES
PRESSURES FROM
L15-VE 165 TO 60,000 PSI
L10-S-VE*
— 8.25 4.38 6.81 7.88 9.68 4.38
L15-S-VE*
7.00
L25-VE 0.50 6.38 AIR
11.62 9.75 8.25 3.63 6.88 7.81 3.19 10.75 INLET
L35-VE 0.411 3.121
7.81 DOUBLE
DIA. 5.00 AIR
L60-VE 1.00 HEAD
L100-VE 12.13 10.19 8.38 3.44 6.88 7.81 3.81 (-2)
L150-VE
1.19
L250-VE 0.411 1/8" FNPT
L300-VE 11.81 10.25 8.38 4.00 6.88 7.81 3.31 DIA. PILOT VALVE
L400-VE 1.00
CATALOG LIQUID
A AS B C D E F 1.31 OUTLET
NUMBER
L10-2-VE
16.12 13.63 12.13 3.88 10.81 11.81 4.38
L15-2-VE
L25-2-VE
15.50 13.75 12.13 3.63 10.81 11.81 3.19
L35-2-VE
F C
L60-2-VE 16.00 14.06 12.38 3.44 10.81 11.81 3.81
LIQUID NOTE: 1
Mounting hole dimensions.
3.38 INLET
L100-2-VE Dimensions are subject to change. Consult factory.
15.50 14.00 12.25 4.00 10.81 11.81 3.81
L150-2-VE
L250-2-VE L500 AND L250-2-VE THROUGH L500-2
L300-2-VE
19.63 18.13 16.25 2.75 10.81 11.75 3.38
L400-2-VE
L500-2
7.00 10.75
6.38 7.81
0.50
3.121 AIR
1.00 INLET 5.00
DOUBLE DOUBLE
AIR AIR
HEAD HEAD
(-2) (-2)
1.19
1/8" NPT
PILOT
1.00 VALVE
0.50
SINGLE B SINGLE
AIR E D1 1.19 AIR
AIR
HEAD INLET AS HEAD
0.12
A
1.31
OPTIONAL 0.411
SIDE LIQUID DIA.
INLET OUTLET
LIQUID
F C INLET 3.38
1
NOTE: Mounting hole dimensions.
Dimensions are subject to change. Consult factory.
16
GX pumps are high-flow pumps designed for rugged installations and built with
environmental resistant materials. They are ideal for offshore applications with
stainless steel wetted parts and corrosive resistant external components.
TECHNICAL DATA
MAXIMUM DISPL.
CONNECTIONS NOTE: The GX pumps have a pilot port that is pre-plumbed.
OUTLET PER This port can be used for control purposes with the
CATALOG PRESSURE PRESSURE CYCLE WEIGHT following modifications:
NUMBER RATIO (PSI) (IN.3) INLET OUTLET (LBS.) Remove the tube from the front of spool valve housing
GX35 1:36 5,220 10.98 1 3⁄8 to bottom face of end cap.
GX60 1:66 8,700 3.97 1 3⁄ 8 53 Remove fitting in spool valve housing and plug with
a 3/8" MNPT plug.
GX100 1:117 14,500 2.20 1 3⁄ 8
Run your pilot air line to the bottom face connection
using 10 mm tube and fittings.
NOTE: All connections listed are FNPT unless otherwise noted.
Air drive inlet connection on all GX pumps is 3/4" FNPT.
Maximum allowable liquid temperature is 140°F.
Air section temperature rating: 0°F to 140°F.
2
Viton is a registered trademark of E.I. DuPont de Nemours & Co., Inc.
9.69
3.50
10.63
10.811 LIQUID
OUTLET
LIQUID INLET
4.331
1
NOTE: Mounting hole dimensions.
Dimensions are subject to change. Consult factory.
17
CHEMICAL SERVICE
PPSF
SERIES
PRESSURES FROM
PPSF series pumps are rugged and designed for chemical service
applications. These pumps are available as single acting pumps with single
air drive head and distance piece which provides a separation between the
liquid and air drive sections.
➠ CATALOG
NUMBER
PPSF4
PRESSURE PRESSURE
RATIO
1:4
(PSI)
580
CYCLE
(IN.3)
1.86
INLET
1
OUTLET
1⁄2
WEIGHT
(LBS.)
DISCHARGE
3
PPSF8 1:9 1,305 0.90 ⁄4 1⁄ 2 15
3 1
PPSF12 1:14 2,030 0.57 ⁄4 ⁄2
➠
SUCTION
3 1
PPSF22 1:28 4,060 0.28 ⁄8 ⁄4
3 1
PPSF37 1:46 6,670 0.17 ⁄8 ⁄4
8
3 1
PPSF72 1:86 12,470 0.09 ⁄8 ⁄4
3 1
PPSF111 1:130 14,500 0.06 ⁄8 ⁄4
NOTE: Air drive inlet connection on all PPSF pumps is 1/4" FNPT.
All connections listed are FNPT unless otherwise noted.
Maximum allowable liquid temperature is 140°F.
Air section temperature rating: 0°F to 140°F.
DIMENSIONS (inches)
3.13 0.19
0.44 1.941 4.63
4.00
1.31 0.62 3.13
CATALOG
A 0.75
NUMBER
DRAIN 0.19
1/8" FNPT LIQUID
0.311
DIA. OUTLET
1.941
LIQUID
INLET 2.00
3.13
1
NOTE: 2
Viton is a registered trademark of NOTE: Mounting hole dimensions.
E.I. DuPont de Nemours & Co., Inc. 4.75 Dimensions are subject to change. Consult factory.
18
0.38
DIMENSIONS (inches) Cont.
3.13
1.941
0.38
0.62
4.63
4.00
3.13 1.31
PPSF
SERIES
PRESSURES FROM
0.75 60 TO 14,500 PSI
AIR
7.13 INLET 5.31
6.311
CATALOG
0.19
NUMBER A B
7.00
A
PPSF22 9.81 2.75
1/8" FNPT
DRAIN PPSF37 9.69 2.69
PPSF72 9.69 2.62
0.311
DIA. PPSF111 9.69 2.63
LIQUID
OUTLET B
LIQUID
1.941 INLET 1.56
2.50 1.81
4.13 NOTE: 1
Mounting hole dimensions.
Dimensions are subject to change. Consult factory.
19
CHEMICAL SERVICE
LSF
SERIES
PRESSURES FROM
LSF series pumps are rugged and designed for chemical service
applications. These pumps are available as single acting pumps with single
or double air drive head and distance piece which provides a separation
between the liquid and air drive sections.
➠
PUMP CATALOG PRESSURE PRESSURE CYCLE WEIGHT
HEAD
NUMBER RATIO (PSI) (IN.3) INLET OUTLET (LBS.)
44
SUCTION LSF15 1:16 2,320 3.78 1 1⁄ 2
1 1
LSF25 1:28 4,060 2.15 ⁄2 ⁄2
42
TYPICAL LSF PUMP LSF35 1:40 5,800 1.49 1
⁄2 1
⁄2
1 1
LSF60 1:63 9,135 0.94 ⁄2 ⁄2
1 1
LSF100 1:113 15,225 0.54 ⁄2 ⁄2
1 9
40
LSF150 1:151 21,025 0.40 ⁄2 ⁄16 –18
SPOOL VALVE ON TOP 1 9
SIDE OF TOP CAP CAP LSF250 1:265 23,200 0.23 ⁄2 ⁄16 –18
1 1
LSF25-2 1:54 8,120 2.15 ⁄2 ⁄2
➠
PUMP 1 1 50
HEAD LSF35-2 1:78 11,600 1.49 ⁄2 ⁄2
1 1
LSF60-2 1:118 15,000 0.94 ⁄2 ⁄2
➠
TYPICAL LSF-2 PUMP NOTE: Air drive inlet connection on all LSF pumps is 1/2" FNPT.
Air pilot connection on all LSF pumps is 1/8" FNPT.
All connections are FNPT unless otherwise noted.
The 9/16 – 18 is a 1/4" O.D. tubing, high pressure coned and threaded connection.
Maximum allowable liquid temperature is 140°F.
Air section temperature rating: 0°F to 140°F.
2
NOTE: Viton is a registered trademark of E.I. DuPont de Nemours & Co., Inc.
20
Single Air Drive Head and Distance Piece DIMENSIONS (inches) 7.00
0.50 6.38 AIR
10.75 INLET
CATALOG 0.41 1 3.121
A AS B C D E F 7.81 DOUBLE
NUMBER DIA. 5.00 AIR
1.00 HEAD
LSF10–LSF15 16.12 13.63 12.13 5.06 6.88 7.81 4.38 (-2)
LSF25–LSF35 15.50 13.63 12.13 3.63 6.88 7.81 3.19 1.19
LSF60–LSF100 1/8" FNPT
16.00 14.06 12.25 3.44 6.88 7.81 3.81 0.411 PILOT VALVE
LSF150 DIA.
1.00
LSF250 15.69 14.13 12.25 4.00 6.88 7.81 3.31
SINGLE
1.19 D1 E AIR
HEAD
Double Air Drive Head and Distance Piece
A AS B
CATALOG
NUMBER A AS B C D E F
LIQUID
1.31 OUTLET
LSF10-2–LSF15-2 20.06 17.56 16.13 5.06 10.81 11.75 4.38
LSF25-2–LSF35-2 19.44 17.56 16.13 3.63 10.81 11.75 3.19
LSF60-2 19.94 18.00 16.25 3.44 10.81 11.75 3.81
LSF100-2 19.94 18.00 16.25 3.44 10.81 11.75 3.31
F C
LIQUID NOTE: 1
Mounting hole dimensions.
3.38 INLET
FLOW CHART — LSF Series Dimensions are subject to change. Consult factory.
SAMPLE
OUTLET PRESSURE (PSI)
AIR DRIVE
CATALOG PRESSURE
NUMBER (PSI) 0 500 1500 3000 5000 7500 10000 15000 23200
60 1100 350
LSF10 90 1125 790
120 1150 915
60 775 540
LSF15 90 790 650
120 800 705 280
60 435 365 60
LSF25 90 445 410 265
120 450 425 340 90
60 300 270 150
LSF35 90 305 290 240 95
120 310 300 270 180
60 192 182 145 45
LSF60 90 195 190 173 130 43
120 200 195 185 158 105 10
60 108 105 97 78 37
LSF100 90 110 108 105 95 78 47 5
120 113 110 107 103 92 73 48
60 81 79 76 66 49 19
LSF150 90 83 82 80 75 67 53 35
120 84 83 82 78 73 66 55 25
60 46 45 44 42 37 26 20 2
LSF250 90 47 46 45 44 43 40 36 26
120 48 47 47 46 45 43 41 34 20
60 880 720
LSF10-2 90 890 800 350
120 900 840 570
60 615 550 200
LSF15-2 90 625 575 410
120 630 600 500 225
60 345 330 265 60
LSF25-2 90 350 335 300 208 15
120 355 345 320 265 150
60 240 230 210 115
LSF35-2 90 242 232 225 190 115
120 245 235 230 210 170 95
60 150 148 145 120 70 2
LSF60-2 90 155 152 147 136 117 80 33
120 157 154 152 145 133 112 82 8
60 86 84 82 77 72 53 30
LSF100-2 90 87 86 84 82 78 70 61 36
120 89 88 86 84 82 77 72 57 13
FLOW RATE IN CUBIC INCHES PER MINUTE. FLOW RATES SHOWN ARE FOR 1-10 CST FLUIDS.
MAXIMUM AIR CONSUMPTION FOR “LSF” PUMPS: 45 SCFM @ 90 PSI (WITH 0 PSI OUTLET). 21
MAXIMUM AIR CONSUMPTION FOR “LSF-2” PUMPS: 80 SCFM @ 90 PSI (WITH 0 PSI OUTLET).
CHEMICAL SERVICE
DC
SERIES
PRESSURES FROM
Dual Component Injection pumps are dual head
pumps designed to pump two different fluids which will be combined to form
polyurethane, acrylic materials or cements as they are injected into floors, walls
and ceilings to seal and reinforce cracks. This is done to prevent moisture seepage
and assist in structural stability, depending on the fluid injected. They are available
525 TO 2,900 PSI with single or double air drive heads.
➠
Standard design has both heads with the same displacement.
➠ For other combinations or pressure ratios, consult factory.
■ Fluids to be used should be identified at time of order to assure
➠ proper materials and seal selection.
➠ SUCTION
TOP
CAP
AIR
CYLINDER
SUCTION TECHNICAL DATA
WITH
PISTON DISCHARGE PUMP MAXIMUM DISPL. PER
HEAD OUTLET CYCLE BOTH CONNECTIONS AIR
CATALOG PRESSURE PRESSURE HEADS INLET WEIGHT
NUMBER RATIO (PSI) (IN.3) INLETS OUTLETS CONNECT. (LBS.)
1 1 1
DCS35PU 1:35 2,900 2.07 ⁄2 ⁄2 ⁄2 35
1 1 1
DCGSF35-2PU 1:41 2,755 3.00 ⁄2 ⁄2 ⁄2 65
3
DCDP40PU 1:41 2,755 14.54 1 ⁄4 1 110
3 3
DCGX45PU 1:45 2,175 9.03 1 ⁄4 ⁄4 80
NOTE: All connections listed are FNPT unless otherwise noted.
Maximum allowable liquid temperature is 140°F.
Air section temperature rating: 0°F to 140°F.
NOTE: 2 Viton is a registered trademark of E.I. DuPont de Nemours & Co., Inc.
ACCESSORIES
To help you complete the installation of your Maximator liquid pump, MAXPRO
offers a wide variety of accessories. These ancillary products are available as
packaged modules or as individual components. Please consult MAXPRO
for details and other support services.
23
OTHER MAXIMATOR POWER PRODUCTS