Você está na página 1de 13

Contents

3 Product Lineup
5 Inverter Technology
7 Special Features
9 Airflow
11 Cleanliness and Durability
13 Function Dictionary
15 Function List
17 Specifications
21 Controller
22 Options

1 2
Lineup

Cooling Only FTKS series Cooling Only FTKD series


Model FTKS25GVMV / RKS25GVMV Model FTKD25HVMV / RKD25HVMV
Cooling kW 2.5 (1.2-3.3) Cooling kW 2.5 (1.2-3.2)
Capacity Btu/h 8,500 (4,050-10,900)
Capacity Btu/h 8,500 (4,100-11,300)

FTKS25/35G RKS25/35G Model FTKS35GVMV / RKS35GVMV FTKD25/35H


RKD25/35H Model FTKD35HVMV / RKD35HVMV
Cooling kW 3.3 (1.3-4.2) Cooling kW 3.2 (1.4-4.0)
Capacity Btu/h 10,900 (4,750-13,650)
Capacity Btu/h 11,300 (4,400-14,300)

Model FTKS50GVMV / RKS50GVMV Model FTKD42HVMV / RKD42HVMV


Cooling kW 5.2 (1.9-6.3) Cooling kW 4.2 (2.0-5.0)
Capacity Btu/h 17,700 (6,500-21,500) Capacity Btu/h 14,300 (6,800-17,100)

Model FTKS60GVMV / RKS60GVMV FTKD42/50/60/71H RKD42H RKD50/60/71H Model FTKD50HVMV / RKD50HVMV


FTKS50/60/71G RKS50/60G RKS71G
Cooling kW 6.0 (1.9-7.1) Cooling kW 5.2 (1.5-5.9)
Capacity Btu/h 20,500 (6,500-24,200) Capacity Btu/h 17,700 (5,100-20,100)

Model FTKS71GVMV / RKS71GVMV Model FTKD60HVMV / RKD60HVMV


Cooling kW 7.1 (2.5-8.7) Cooling kW 6.2 (1.5-6.5)
Capacity Btu/h 24,200 (8,500-29,700) Capacity Btu/h 21,200 (5,100-22,200)

Model FTKD71HVMV / RKD71HVMV


Cooling kW 7.1 (2.1-7.6)
Capacity Btu/h 24,200 (7,200-25,900)

Heat Pump FTXS series Heat Pump FTXD series


Model FTXS25GVMV / RXS25GVMV Model FTXD25HVMV / RXD25HVMV
Cooling kW 2.5 (1.2-3.0) Cooling kW 2.5 (1.3-3.0)
Capacity Btu/h 8,500 (4,100-10,200) Capacity Btu/h 8,500 (4,400-10,200)
Heating kW 3.4 (1.2-4.5) Heating kW 3.4 (1.3-4.0)
Capacity Btu/h 11,600 (4,100-15,350) Capacity
FTXS25/35G RXS25/35G Btu/h 11,600 (4,400-13,650)
FTXD25/35H RXD25/35H

Model FTXS35GVMV / RXS35GVMV Model FTXD35HVMV / RXD35HVMV


Cooling kW 3.5 (1.2-3.8) Cooling kW 3.5 (1.4-3.8)
Capacity Btu/h 11,900 (4,100-12,950) Capacity Btu/h 11,900 (4,750-12,950)
Heating kW 4.0 (1.2-5.0) Heating kW 4.2 (1.4-5.0)
Capacity Btu/h 13,600 (4,100-17,050) Capacity Btu/h 14,300 (4,750-17,050)

Model FTXS50GVMV / RXS50GVMV Model FTXD50HVMV / RXD50HVMV


Cooling kW 5.0 (1.7-6.0) Cooling kW 5.2 (1.5-5.9)
Capacity Btu/h 17,100 (5,800-20,500) Capacity Btu/h 17,700 (5,100-20,100)
Heating kW 5.8 (1.7-7.7) Heating kW 6.5 (1.5-8.0)
Capacity Btu/h 19,800 (5,800-26,300) Capacity
FTXS50/60/71G RXS50/60G RXS71G FTXD50/60/71H RXD50/60/71H
Btu/h 22,200 (5,100-27,300)

Model FTXS60GVMV / RXS60GVMV Model FTXD60HVMV / RXD60HVMV


Cooling kW 6.0 (1.7-6.7) Cooling kW 6.2 (2.2-7.6)
Capacity Btu/h 20,500 (5,800-22,900) Capacity Btu/h 21,200 (7,500-25,900)
Heating kW 7.0 (1.7-8.0) Heating kW 7.2 (2.2-9.0)
Capacity Btu/h 23,900 (5,800-27,300) Capacity Btu/h 24,600 (7,500-30,700)

Model FTXS71GVMV / RXS71GVMV Model FTXD71HVMV / RXD71HVMV


Cooling kW 7.1 (2.3-8.5) Cooling kW 7.1 (2.9-8.0)
Capacity Btu/h 24,200 (7,800-29,000) Capacity Btu/h 24,200 (9,900-27,300)
Heating kW 8.2 (2.3-10.0) Heating kW 8.5 (2.9-9.7)
Capacity Btu/h 28,000 (7,900-34,100) Capacity Btu/h 29,000 (9,900-33,100)

Model Capacity range Model Capacity range


name 25 35 42 50 60 71 name 25 35 42 50 60 71
Cooling only FTKS Cooling only FTKD

Heat pump FTXS Heat pump FTXD

3 4
Inverter Technology

Inverter Advantages Compared to Non-Inverter Energy-Saving Technological Features

Swing Compressor
Features of Inverter Technology
Thanks to its smooth rotation, the Refrigerant gas
An inverter is a device for converting frequency. The technology is used in many home appliances and Swing bush
swing compressor decreases
controls the electric voltage, current and frequency. Inverter air conditioners can vary their cooling/heating friction and vibration. It also
capacity by adjusting the power supply frequency of their compressors. In contrast, non-inverter air prevents the leakage of
conditioners have a fixed cooling/heating capacity and can only control the indoor temperature by refrigerant gas during
compression. These advantages
starting or stopping their compressors. As a result, inverter air conditioners are more energy-saving and provide quiet and efficient
Integral piston of
blade and roller
comfortable than non-inverter air conditioners. Swing compressor
operation. The swing compressor can
reduce operational vibration and
Reluctance DC motor sound because its piston moves
smoothly inside the compressor.

Powerful Variable Capacity Operation


Inverter air conditioners operate at Inverter Power Control Compressor High Reluctance DC Motor for Compressors
maximum capacity as soon as they Raise frequency High-speed rotation capacity Daikin DC Inverter models are equipped with Efficiency of Reluctance DC motor *4
start up. As a result, the set Power the Reluctance DC motor for compressors. The
source Low Reluctance DC motor
90
temperature can be reached more Lower frequency Low-speed rotation Reluctance DC motor uses 2 different types of

Motor efficiency (%)


capacity
quickly. torque, neodymium magnet*1 and reluctance
80
Non-inverter type air conditioner Compressor torque*2. This motor saves energy by generating Conventional
more power with a smaller electric current than More than 20%
DC motor
70
Energy Saving Power Constant speed Fixed capacity AC or conventional DC motors. It is more
source rotation efficient at the low frequencies most commonly AC motor
After the indoor temperature 60
Neodymium magnets are used used by air conditioners,*3 improving efficiency
approaches the set temperature, Inverter air conditioners are able to vary their operating capacity. Non-inverter air conditioners can in the pink-coloured area.
only operate at a fixed capacity.
by approximately 20%.
Inverter Control adjusts to low 50
0 30 60 90 120
Rotational speed (rps)
capacity operation to maintain this
Small load Large load
temperature. This makes inverter *1. A neodymium magnet is approximately 10 times stronger than a standard ferrite
Low capacity High capacity
magnet.
models more energy-saving than *2. The torque created by the change in power between the iron and magnet parts. *4. Data are based on studies conducted
non-inverter models, which must Comfortable Temperature Control *3. The frequency range used by air conditioners during periods of stable operation. under controlled conditions at a Daikin
This is the range in which air conditioners operate for the longest periods. laboratory.
repeatedly start or stop their
compressors to maintain the room Temp.
temperature.
Compressor off
Not cool
DC Motor for Fans PAM Control
Comfortable The DC motor allows fine rotation Efficiency of DC motor for fans *5
(Comparison with conventional AC motor)
Inverter air conditioners finely adjust Set control, which reduces energy 100

Efficiency (%)
temp. Compressor off
consumption. The motor also
capacity according to changes in the 80
provides improvements in DC motor
air-conditioning load and the difference operational efficiency of up to 40%, 60
Approx.
20%
Small temp. increase
between the indoor temperature and Cools a room difference compared to an AC motor. These PAM (Pulse Amplitude Modulation)
40
set temperature is small. They give in less time Time improvements are particularly
Approx.
40%
AC motor control reduces energy loss by
Too cool During cooling operation noticeable in the low-speed range. 20 increase controlling how often the converter
higher comfort levels than with non-
0 switches on and off.
inverter air conditioners. Non-inverter type 200 300 400 500 600 700 800 900 1000
Motor speed (rpm)
Inverter type
Starts *5. Data are based on studies conducted
This diagram is a representation for illustrative purposes only. under controlled conditions at a Daikin
laboratory.

What Is DC Inverter?
Daikin calls an inverter model that is equipped with a DC motor DC Inverter. A DC motor offers higher efficiency
than an AC motor. A DC motor uses the power of magnets to attract and repel to generate rotation. A DC motor
that is equipped with high-power neodymium magnets, which enable even greater efficiency, is called a Reluctance
DC motor.

5 6
Special Features

Intelligent Eye Indoor Unit Quiet Operation


Intelligent Eye prevents energy wastage by using its Top view This series gives you the choice of 5-step, Quiet or
infrared sensor to detect human movement in a room. Automatic settings for the fan speed. The Quiet setting
When there is no movement, Intelligent Eye increases the selects Indoor Unit Quiet Operation, which decreases
7m
temperature by 2 C to give energy savings. This reduces the sound pressure level by 3 dB (A) below the Low
energy wastage if, for example, you forget to turn off the 110˚ setting. This wide range of settings allows you to
air conditioner. This function can be conveniently precisely control the fan speed according to your
activated from the remote controller. needs. For example, the Quiet function will help you to
Once Intelligent Eye is set, it continues to work to save energy. You do not sleep comfortably at night. The sound pressure level
need to push the SENSOR button each time you wish to use this function. The Intelligent Eye Intelligent Eye Side view
indicator lights when sensor 7m for the FTKS25G is 22 dB (A).
movement is detected.

FTKS25G
Fan speeds Sound pressure levels

High (H) 37 dB (A)

Low (L) 25 dB (A)


3 dB(A) Auto SL L M H
Quiet (SL) 22 dB (A)

When you are in the room, the air If Intelligent Eye detects no human When you enter the room, Fan
conditioner maintains the set movement for 20 minutes, it Intelligent Eye automatically Low High
speed
temperature. automatically adjusts the set returns the temperature to the
temperature by 2 C. set level.
Sound Each decrease in airflow volume
Indoor Unit Quiet Operation icon pressure reduces the sound pressure level.
Econo Mode button level

Intelligent Eye button

Selects fan speed and


Indoor Unit Quiet Operation

Outdoor Unit Quiet Operation


Econo Mode

This function limits both the maximum running current


and maximum power consumption. It is particularly Running current and
effective if the cooling load is high, for example, at start- power consumption
Maximum during
up or during large gatherings and periods of direct Normal normal operation
sunshine. operation Outdoor Unit Quiet Operation 22 dB (A) Is So Quiet You Can Even Hear Whispers
Econo Mode is also useful for preventing circuit
breakers from being overloaded during temporary Maximum during
This function decreases the sound pressure level by
peaks in the running current. The function is easily Econo Mode 3 dB (A) below the rated operation. It provides a low
activated from the remote controller by pushing the sound pressure level of 43 dB (A) for the RK(X)S25G. Indoor unit Outdoor unit
Econo Capacity may decrease when Outdoor Unit Quiet
ECONO button. Mode
This function is not available for FTXS50/60/71G and FTXD50/60/71H. Operation is selected.
20 22 30 40 43 50 (dB (A))
Time RK(X)S25G
From start-up until set
temperature is reached Operations Sound pressure levels
Rustling of leaves Library
• This diagram is a representation for illustrative purposes only. Rated (H) 46 dB (A)
• Maximum capacity decreases during Econo Mode, requiring Pendulum of a wall clock Normal office
more time to reach the set temperature. 3 dB (A)
Quiet (SL) 43 dB (A) Based on “Examples of Sound Levels”, Ministry of the Environment, Japan,
November 12, 2002

7 8
Airflow

Power-Airflow Dual Flaps Vertical Auto-Swing (up and down) Inverter Powerful Operation Home Leave Operation
Inverter Powerful Operation boosts cooling/heating Home Leave Operation prevents large rises or falls in
Wide-Angle Louvers Horizontal Auto-Swing (left and right) performance for a 20-minute period. This is convenient the indoor temperature by continuing operation* while
both when you first turn on your air conditioner and you are sleeping or out of your home. This means that
when you want to quickly change the temperature an air-conditioned welcome awaits when you wake or
Power-Airflow Dual Flaps and Wide-Angle Louvers work 3-D Airflow during operation. return. It also means that the indoor temperature can
in tandem to precisely control both vertical and horizontal
quickly return to your favourite comfort setting.
airflow for distribution of air.
Vertical Auto-Swing automatically moves the flaps up This function is available for FTXS50/60/71G and FTXD50/60/71H.
and down and Horizontal Auto-Swing automatically * Home Leave Operation can be set at any temperature from 18 to 32 C
Power-Airflow Dual Flaps for cooling operation and 10 to 30 C for heating operation.
moves the louvers to the left and right. 3-D Airflow
combines Vertical and Horizontal Auto-Swing to circulate
air to every part of a room for uniform cooling/heating of During operation, 23 C for the room
even large spaces. temperature setting, and 28 C for
the Home Leave setting.
Horizontal Auto-Swing and 3-D Airflow are not available for 2.5 and 3.5 kW
models.
23 C

Indoor Unit On/Off Switch

The unit can be conveniently


started manually in the event the
wireless remote controller is
One push!!
misplaced or the wireless remote
Start Home Leave
Cooling: the flaps flatten out during Heating: the flaps descend to blow controller batteries are not Operation simply by
operation so that cool air slides off to warm air directly down to the floor to charged. Indoor Unit On/Off Switch pushing its button on the
reach the corner of the room. quickly warm the whole room. remote controller.

Wide-Angle Louvers 28 C

Night Set Mode When you are out of


your home, your air
conditioner prevents
Pressing the Off timer button automatically selects Night large rises in the indoor
Set Mode. This function prevents excessive cooling or temperature by
continuing to operate
Comfort Airflow Mode heating for a pleasant sleep. Room temperature is raised using Home Leave
by 0.5 C after 60 minutes for cooling operation and the Operation settings.
The louvers can be adjusted
Comfort Airflow Mode prevents uncomfortable drafts temperature is lowered by 2 C after 60 minutes for heating
by hand for 2.5 and 3.5 kW
From a corner models and with the from blowing directly on to your body. With this operation.
to the centre wireless remote controller
for 4.2 to 7.1 kW models.
function, when you press the COMFORT button, the
flap moves upward to prevent direct cold drafts.
23 C
+0.5 C Cooling
This function is available for FTKS50/60/71G and FTKD42/50/60/71H. Set temp. before
Off timer begins
to operate

-2 C Heating

Time 60 minutes
Off timer turns on Off timer stops air conditioner Push again!!
Cooling operation: Room temperature is raised by 0.5 C after 60 minutes. When you return, you will
Heating operation: Room temperature is lowered by 2 C after 60 minutes. be greeted by an air-
conditioned room. Just
Covers even push the HOME LEAVE
a spacious room button again to return to
your previous settings.

9 10
Cleanliness and Durability

Installation Flexibility
Titanium Apatite Photocatalytic Anticorrosion Treatment of Outdoor A long piping length gives installation flexibility.
Air-Purifying Filter Heat Exchanger Fins Installation is possible even if there is no space for the
Titanium apatite is a new photocatalytic material The outdoor unit’s heat exchanger fins are processed outdoor unit near the indoor unit.
with advanced adsorption power. While the filter’s using a special anticorrosion treatment. The surface is
micron-level fibres trap dust, this photocatalyst effectively Air filter covered with a thin acrylic resin layer to enhance the Max. piping Max. height
adsorbs and decomposes bacteria. The photocatalyst is Catches dust fins’ resistance to acid rain and salt corrosion. length difference
activated simply by exposure to light. The filter delivers A hydrophilic film layer also prevents rust caused by the
consistent performance for approximately 3 years if run off of water droplets. FTKS25/35G
FTXS25/35G 20 m
washing with water is performed once every 6 months.
FTXD25/35H
15 m
Cross section of anticorrosion-treated fin
Titanium Apatite
Photocatalytic FTKD25/35/42H 25 m
Air-Purifying Filter Hydrophilic film
Aluminium
Bacteria Removal Test Corrosion-resistant FTKS50/60/71G
acrylic resin
Testing method: Dropping method This filter is not a medical device. Benefits such as the FTXS50/60/71G 30 m
Testing organisation: Japan Spinners Inspecting Foundation adsorption and decomposition of bacteria are only effective 20 m
Result certificate: No. 012553-1 and 012553-2 for substances that are collected on and in direct contact with
FTKD50/60/71H
the Titanium Apatite Photocatalytic Air-Purifying Filter. FTXD50/60/71H

Effect of Titanium Apatite Photocatalyst


Heat exchanger fin
Adsorbs Removes
Apatite adsorbs bacteria.
At the same time, the
Light
photocatalyst oxidises
odour components,
Odours
Decomposed breaking them down.
Bacteria
Decomposed
Wide Operation Range
Titanium Apatite Photocatalyst With the heat pump type, cooling operation is possible
even during outdoor temperatures of as low as 10 C.
Heating operation can also be performed during
outdoor temperatures of -15 to 18 C. This makes these
units ideal for even very cold areas.
Piping connections for the outdoor unit are covered to
make them less conspicuous.
Mould-Proof Operation Wipe-Clean Flat Panel Heat pump FTXD50/60/71H

When cooling or dry operation is stopped, fan-only Flat panel models can be cleaned instantly with a 50 Cooling 50

operation runs automatically for 1 hour. This airflow single wipe of a cloth across their smooth surface. If 40 40

Outdoor temp. (˚CWB)


Outdoor temp. (˚CDB)
dries the inside of the indoor unit to reduce the more thorough cleaning is required, the panel can also
30 30
generation of mould and odours. be easily removed from the unit.
20 20
Heating
This function is available for 2.5 and 3.5 kW models. Conventional Front Grille Design
10 10

1. Difficult to remove dust on 0 0


the grille through wiping
alone -10 -10

-20 -20

2. Reduced capacity due to


Dust increased suction resistance

Front grille design units


collect dust on their air inlet 3. High sound levels due to
grilles unless these grilles increased suction
are cleaned regularly. resistance

11 12
Function Dictionary

Comfortable Airflow Comfort Control Timers Others

Power-Airflow Dual Flaps Indoor Unit Quiet Operation 24-Hour On/Off Timer Comfort Control
Power-Airflow Dual Flaps can flatten out during cooling Indoor unit operating sound pressure levels are decreased This timer can start or stop the air conditioner within a 24- Quick Warming Function
operation to deliver cool air to the corners of a room. The from the Low setting fan speed using the wireless remote hour period. It can be preset in 10-minute steps by pressing During low outdoor temperatures, this function pre-heats
flaps can direct warm air straight down to the floor during controller. the On/Off timer button on the wireless remote controller. the compressor to shorten the time required to discharge
heating operation. See page 8 The On timer and Off timer can be used in combination. warm air.
See page 9
Outdoor Unit Quiet Operation Night Set Mode
Wide-Angle Louvers Outdoor unit operating sound pressure levels are decreased
Automatic Defrosting
The smoothly curved Wide-Angle Louvers provide wide Pressing the Off timer button automatically selects Night Before starting heating operation, a sensor checks for
from the rated operation sound using the wireless remote
airflow coverage for effective operation no matter where Set Mode. This function prevents excessive cooling or frost in the outdoor unit and performs automatic defrosting
controller.
the indoor unit is placed in a room. heating for a pleasant sleep. After 60 minutes, the room if necessary so that only warm air is discharged.
See page 8
See page 9 temperature is raised by 0.5 C for cooling operation or
Intelligent Eye lowered by 2 C for heating operation.
These 2 functions are available with the heat pump type.
Vertical Auto-Swing (up and down) Intelligent Eye with its infrared sensor automatically controls See page 10
This function automatically moves the flaps up and down air conditioner operation according to human movement in
to distribute air across a room. a room. When there is no movement, it adjusts the
See page 9 temperature by 2 C for energy savings.
See page 7 Worry Free
Horizontal Auto-Swing (left and right)
Horizontal Auto-Swing automatically moves the louvers Automatic Operation
to the left and right to cover a room with cool/warm air. This function automatically selects cooling or heating Auto-Restart after Power Failure
See page 9 operation mode based on the room temperature at start- The air conditioner memorises the settings for mode,
up. This function is available with the heat pump type. airflow, temperature, etc., and automatically returns to
3-D Airflow them when power is restored after a power failure.
This function combines Vertical and Horizontal Auto-Swing Programme Dry Function
to circulate a cloud of cool/warm air right to the corners of The computer chip works to rid the room of humidity while Self-Diagnosis with Digital Display
even large spaces. The flaps and louvers swing in turn. maintaining the most consistent temperature possible. It Malfunction codes are shown on the digital display panel
See page 9 automatically controls the temperature and airflow rate. of the wireless remote controller for fast and easy
maintenance.
Comfort Airflow Mode Auto Fan Speed
This function prevents uncomfortable drafts from blowing Anticorrosion Treatment of Outdoor
The microprocessor automatically controls fan speed to
directly on to the body. To prevent drafts, the flap moves
upward during cooling operation and downward during
adjust the room temperature to the set temperature. Heat Exchanger Fins
heating operation. The outdoor unit’s heat exchanger fins are processed
See page 9 using a special anticorrosion treatment. The surface is
covered with a thin acrylic resin layer to enhance the fins’
resistance to acid rain and salt corrosion.
See page 12
Lifestyle Convenience Cleanliness

Standby Electricity Saving Titanium Apatite Photocatalytic


Even when an air conditioner is not operating, it Air-Purifying Filter
requires standby power. However, thanks to this This filter contains the advanced photocatalytic material
function, the required standby power can be reduced. titanium apatite. While the filter’s micron-level fibres trap
dust, this photocatalyst adsorbs and decomposes
Econo Mode bacteria. The filter can be used for up to 3 years with
This mode limits maximum running current and power proper maintenance.
consumption. This improves operating efficiency and also
See page 11
prevents circuit breakers from being overloaded.
See page 7
Air-Purifying Filter with Photocatalytic
Inverter Powerful Operation Deodorising Function
This filter is made of titanium oxide. It adsorbs and
This function is convenient for boosting cooling/heating decomposes bacteria. The filter can be used for up to 3
performance for a 20-minute period both when you first years with proper maintenance.
turn on your air conditioner or want to quickly change the
room temperature.
See page 10 Mould-Proof Operation
Mould-Proof Operation automatically runs fan-only
Home Leave Operation operation for 1 hour when cooling or dry operation is
stopped. This airflow prevents the generation of mould
Home Leave Operation continues operation to prevent a
and mould odours inside the indoor unit.
room from becoming too hot or cold, while you are
sleeping or out of your home. Select any temperature See page 11
from 18 to 32 C for cooling operation and 10 to 30 C for
heating operation.
Wipe-Clean Flat Panel
See page 10
The flat panel design can be cleaned with only the single
pass of a cloth across its smooth surface. The flat panel
Indoor Unit On/Off Switch can also be easily removed for more thorough cleaning.
The unit can be conveniently started manually in the See page 11
event the wireless remote controller is misplaced or the
wireless remote controller batteries are not charged.
See page 10

13 14
Function List
Indoor Unit
Models
Cooling Only FTKS series Heat Pump FTXS series Cooling Only FTKD series Heat Pump FTXD series

FTKS25/35G FTKS50/60/71G FTXS25/35G FTXS50/60/71G FTKD25/35H FTKD42/50/60/71H FTXD25/35H FTXD50/60/71H


Functions

DC Inverter

Power-Airflow Dual Flaps

Wide-Angle Louvers
Comfortable Airflow

Vertical Auto-Swing (up and down)

Horizontal Auto-Swing (left and right)

3-D Airflow

Comfort Airflow Mode

Indoor Unit Quiet Operation


Comfort Control

Intelligent Eye

Automatic Operation

Programme Dry Function

Auto Fan Speed

Standby Electricity Saving


Lifestyle Convenience

Econo Mode

Inverter Powerful Operation

Home Leave Operation

Indoor Unit On/Off Switch

Titanium Apatite Photocatalytic Air-Purifying Filter


Cleanliness

Air-Purifying Filter with Photocatalytic Deodorising Function

Mould-Proof Operation

Wipe-Clean Flat Panel

24-Hour On/Off Timer


Timers

Night Set Mode


Worry Free

Auto-Restart after Power Failure

Self-Diagnosis with Digital Display

Outdoor Unit
Models
Functions RKS25/35G RKS50/60/71G RXS25/35G RXS50/60/71G RKD25/35H RKD42/50/60/71H RXD25/35H RXD50/60/71H
Worry Comfort
Free Control

Outdoor Unit Quiet Operation

Anticorrosion Treatment of Outdoor Heat Exchanger Fins

15 16
Specifications Cooling Only Specifications Heat Pump
FTKS25/35G FTXS25/35G
Indoor unit FTKS25GVMV FTKS35GVMV Indoor unit FTXS25GVMV FTXS35GVMV
Model name Model name
Outdoor unit RKS25GVMV RKS35GVMV Outdoor unit RXS25GVMV RXS35GVMV
kW 2.5 (1.2-3.3) 3.3 (1.3-4.2) Rated kW 2.5 (1.2-3.0) 3.5 (1.2-3.8)
Capacity Rated (Min.-Max.) Cooling
Btu/h 8,500 (4,100-11,300) 11,300 (4,400-14,300) (Min.-Max.) Btu/h 8,500 (4,100-10,200) 11,900 (4,100-12,950)
Capacity
Power supply 1 phase, 220-240 V/220-230 V, 50/60 Hz Rated kW 3.4 (1.2-4.5) 4.0 (1.2-5.0)
Heating
Running current Rated A 3.4 4.4 (Min.-Max.) Btu/h 11,600 (4,100-15,350) 13,600 (4,100-17,050)
Power consumption Rated W 583 892 Power supply 1 phase, 220-240 V/220-230 V, 50/60 Hz
CSPF 4.16 5.08 Cooling 3.5 4.9
Running current Rated A
Indoor unit FTKS25GVMV FTKS35GVMV Heating 4.3 5.1
Front panel colour White Cooling Rated 600 (300-800) 1,020 (300-1,200)
Power consumption W
Airflow rate (H) m3/min (cfm) 9.0 (318) 8.9 (314) Heating (Min.-Max.) 830 (290-1,340) 1,080 (290-1,550)
Fan speed 5 steps, quiet and automatic CSPF 4.176 4.982
Sound pressure level (H/L/SL) dB (A) 37/25/22 38/26/23 Indoor unit FTXS25GVMV FTXS35GVMV
Dimensions (H x W x D) mm 283 x 800 x 195 Front panel colour White
Machine weight kg 9 Cooling m3/min 8.7 (307) 8.9 (314)
Airflow rate (H)
Outdoor unit RKS25GVMV RKS35GVMV Heating (cfm) 9.4 (332) 9.7 (342)
Casing colour Ivory white Fan speed 5 steps, quiet and automatic
Type Hermetically sealed swing type Sound pressure Cooling 37/25/22 38/26/23
Compressor level (H/L/SL) dB (A)
Motor output W 600 Heating 37/28/25 38/29/26
Refrigerant charge (R-410A) kg 1.0 Dimensions (H x W x D) mm 283 x 800 x 195
Sound pressure level (H/SL) dB (A) 46/43 47/44 Machine weight kg 9
Dimensions (H x W x D) mm 550 x 765 x 285 Outdoor unit RXS25GVMV RXS35GVMV
Machine weight kg 34 Casing colour Ivory white
Operation range CDB 19.4 to 46 Type Hermetically sealed swing type
Compressor
Liquid 6.4 Motor output W 600
Piping connections Gas mm 9.5 Refrigerant charge (R-410A) kg 1.00
Drain 18.0 Sound pressure Cooling 46/43 47/44
level (H/SL) dB (A)
Max. piping length 20 Heating 47/44 48/45
m Dimensions (H x W x D) mm 550 x 765 x 285
Max. height difference 15
Note: The above values are based on operation with a 220 V, 50 Hz power supply. Machine weight kg 34
Cooling CDB 10 to 46
Operation range
FTKS50/60/71G Heating CWB 15 to 20
Liquid 6.4
Indoor unit FTKS50GVMV FTKS60GVMV FTKS71GVMV Piping connections Gas mm 9.5
Model name
Outdoor unit RKS50GVMV RKS60GVMV RKS71GVMV Drain 18.0
kW 5.2 (1.9-6.3) 6.0 (1.9-7.1) 7.1 (2.5-8.7) Max. piping length 20
Capacity Rated (Min.-Max.)
Btu/h 17,700 (6,500-21,500) 20,500 (6,500-24,200) 24,200 (8,500-29,700) m
Max. height difference 15
Power supply 1 phase, 220-240 V/220-230 V, 50/60 Hz
Note: The above values are based on operation with a 220 V, 50 Hz power supply.
Running current Rated A 6.4 8.4 10.4
Power consumption Rated W 1,397 1,765 2,283
CSPF 5.09 5.54 4.61 FTXS50/60/71G
Indoor unit FTKS50GVMV FTKS60GVMV FTKS71GVMV Indoor unit FTXS50GVMV FTXS60GVMV FTXS71GVMV
Front panel colour White Model name
Outdoor unit RXS50GVMV RXS60GVMV RXS71GVMV
Airflow rate (H) m3/min (cfm) 14.3 (504) 15.4 (544) 16.3 (575) Rated kW 5.0 (1.7-6.0) 6.0 (1.7-6.7) 7.1 (2.3-8.5)
Fan speed 5 steps, quiet and automatic Cooling
(Min.-Max.) Btu/h 17,100 (5,800-20,500) 20,500 (5,800-22,900) 24,200 (7,800-29,000)
Sound pressure level (H/L/SL) dB (A) 43/34/31 45/35/32 46/37/34 Capacity
Rated kW 5.8 (1.7-7.7) 7.0 (1.7-8.0) 8.2 (2.3-10.0)
Dimensions (H x W x D) mm 290 x 1,050 x 250 Heating
(Min.-Max.) Btu/h 19,800 (5,800-26,300) 23,900 (5,800-27,300) 28,000 (7,900-34,100)
Machine weight kg 12 Power supply 1 phase, 220-240 V/220-230 V, 50/60 Hz
Outdoor unit RKS50GVMV RKS60GVMV RKS71GVMV Cooling 7.2 9.2 10.8
Casing colour Ivory white Running current Rated A
Heating 7.4 9.4 11.6
Type Hermetically sealed swing type Cooling Rated 1,550 (440-2,080) 1,980 (440-2,390) 2,360 (570-3,200)
Compressor Power consumption W
Motor output W 1,100 1,920 Heating (Min.-Max.) 1,600 (400-2,530) 2,040 (400-2,810) 2,520 (520-3,730)
Refrigerant charge (R-410A) kg 1.5 1.9 CSPF 4.891 4.61 4.501
Sound pressure level (H/SL) dB (A) 48/44 52/46 52/49 Indoor unit FTXS50GVMV FTXS60GVMV FTXS71GVMV
Dimensions (H x W x D) mm 735 x 825 x 300 770 x 900 x 320 Front panel colour White
Machine weight kg 43 60 Cooling m3/min 14.7 (519) 16.2 (572) 17.4 (614)
Operation range CDB 19.4 to 46 Airflow rate (H)
Heating (cfm) 16.2 (572) 17.4 (614) 21.5 (759)
Liquid 6.4 Fan speed 5 steps, quiet and automatic
Piping connections Gas mm 12.7 15.9 Cooling 44/35/32 45/36/33 46/37/34
Sound pressure dB (A)
Drain 18.0 level (H/L/SL) Heating 42/33/30 44/35/32 46/37/34
Max. piping length 30 Dimensions (H x W x D) mm 290 x 1,050 x 238
m
Max. height difference 20 Machine weight kg 12
Note: The above values are based on operation with a 220 V, 50 Hz power supply. Outdoor unit RXS50GVMV RXS60GVMV RXS71GVMV
Casing colour Ivory white
Measurement conditions Type Hermetically sealed swing type
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; piping length 7.5 m. Compressor
Motor output W 1,100 1,920
2. Sound pressure levels are based on the temperature conditions 1. above. These are anechoic conversion values. These values are normally somewhat higher during
Refrigerant charge (R-410A) kg 1.50 2.30
actual operation as a result of ambient conditions.
3. CSPF is based on TCVN 7830: 2012 conditions. Sound pressure Cooling 47/44 49/46 52/49
dB (A)
level (H/SL) Heating 48/45 49/46 52/49
Dimensions (H x W x D) mm 735 x 825 x 300 770 x 900 x 320
Machine weight kg 48 71
Cooling CDB 10 to 46
Operation range
Heating CWB 15 to 18
Liquid 6.4
Piping connections Gas mm 12.7 15.9
Drain 18.0
Max. piping length m 30
Max. height difference m 20
Note: The above values are based on operation with a 220 V, 50 Hz power supply.
Measurement conditions
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; piping length 7.5 m.
2. Heating capacity is based on: indoor temp. 20 CDB; outdoor temp. 7 CDB, 6 CWB; piping length 7.5 m.
3. Sound pressure levels are based on the temperature conditions 1. and 2. above. These are anechoic conversion values. These values are normally somewhat higher
during actual operation as a result of ambient conditions.
4. CSPF is based on TCVN 7830: 2012 conditions.

17 18
Specifications Cooling Only Specifications Heat Pump
FTKD25/35H FTXD25/35H
Indoor unit FTKD25HVMV FTKD35HVMV Indoor unit FTXD25HVMV FTXD35HVMV
Model name Model name
Outdoor unit RKD25HVMV RKD35HVMV Outdoor unit RXD25HVMV RXD35HVMV
kW 2.5 (1.2-3.2) 3.2 (1.4-4.0) Rated kW 2.5 (1.3-3.0) 3.5 (1.4-3.8)
Capacity Rated (Min.-Max.) Cooling
Btu/h 8,500 (4,050-10,900) 10,900 (4,750-13,650) (Min.-Max.) Btu/h 8,500 (4,400-10,200) 11,900 (4,750-12,950)
Capacity
Power supply 1 phase, 220-240 V/220-230 V, 50/60 Hz Rated kW 3.4 (1.3-4.0) 4.2 (1.4-5.0)
Heating
Running current Rated A 3.9 4.2 (Min.-Max.) Btu/h 11,600 (4,400-13,650) 14,300 (4,750-17,050)
Power consumption Rated (Min.-Max.) W 685 (294-1,100) 888 (301-1,429) Power supply 1 phase, 220-240 V/220-230 V, 50/60 Hz
CSPF 3.82 4.85 Cooling 4.2 5.4
Running current Rated A
Indoor unit FTKD25HVMV FTKD35HVMV Heating 5.1 6.2
Front panel colour White Cooling Rated 725 (310-1,030) 1,130 (305-1,370)
Power consumption W
Airflow rate (H) m3/min (cfm) 8.9 (314) 9.0 (318) Heating (Min.-Max.) 1,000 (310-1,220) 1,310 (330-1,580)
Fan speed 5 steps, quiet and automatic CSPF 3.98 4.93
Sound pressure level (H/L/SL) dB (A) 37/28/25 39/29/26 Indoor unit FTXD25HVMV FTXD35HVMV
Dimensions (H x W x D) mm 283 x 800 x 195 Front panel colour White
Machine weight kg 9 Cooling m3/min 8.9 (314) 9.0 (318)
Airflow rate (H)
Outdoor unit RKD25HVMV RKD35HVMV Heating (cfm) 9.4 (332) 9.7 (342)
Casing colour Ivory white Fan speed 5 steps, quiet and automatic
Type Hermetically sealed swing type Sound pressure Cooling 37/28/25 38/29/26
Compressor level (H/L/SL) dB (A)
Motor output W 600 Heating 37/28/25 38/29/26
Refrigerant charge (R-22) kg 0.75 0.90 Dimensions (H x W x D) mm 283 x 800 x 195
Sound pressure level (H/SL) dB (A) 46/43 47/44 Machine weight kg 9
Dimensions (H x W x D) mm 550 x 765 x 285 Outdoor unit RXD25HVMV RXD35HVMV
Machine weight kg 32 34 Casing colour Ivory white
Operation range CDB 19.4 to 46 Type Hermetically sealed swing type
Compressor
Liquid 6.4 Motor output W 600
Piping connections Gas mm 9.5 12.7 Refrigerant charge (R-22) kg 0.90 1.20
Drain 18.0 Sound pressure Cooling 46/43 47/44
level (H/SL) dB (A)
Max. piping length 25 Heating 47/44 48/45
m Dimensions (H x W x D) mm 550 x 765 x 285
Max. height difference 15
Machine weight kg 31 33
Cooling CDB 10 to 46
Operation range
Heating CWB 10 to 20
FTKD42/50/60/71H Liquid 6.4
Indoor unit FTKD42HVMV FTKD50HVMV FTKD60HVMV FTKD71HVMV
Model name Piping connections Gas mm 9.5 12.7
Outdoor unit RKD42HVMV RKD50HVMV RKD60HVMV RKD71HVMV
Drain 18.0
kW 4.2 (2.0-5.0) 5.2 (1.5-5.9) 6.2 (1.5-6.5) 7.1 (2.1-7.6)
Capacity Rated (Min.-Max.) Max. piping length 20
Btu/h 14,300 (6,800-17,100) 17,700 (5,100-20,100) 21,200 (5,100-22,200) 24,200 (7,200-25,900) m
Max. height difference 15
Power supply 1 phase, 220-240 V/220-230 V, 50/60 Hz
Note: The above values are based on operation with a 220 V, 50 Hz power supply.
Running current Rated A 5.4 7.3 9.2 11.5
Power consumption Rated (Min.-Max.) W 1,167 (520-1,600) 1,575 (420-2,300) 2,000 (440-2,600) 2,491 (540-3,176)
CSPF 5.90 5.16 5.63 4.72 FTXD50/60/71H
Indoor unit FTKD42HVMV FTKD50HVMV FTKD60HVMV FTKD71HVMV Indoor unit FTXD50HVMV FTXD60HVMV FTXD71HVMV
Front panel colour White Model name
Outdoor unit RXD50HVMV RXD60HVMV RXD71HVMV
Airflow rate (H) m3/min (cfm) 15.3 (540) 17.5 (618) 18.3 (646) Rated kW 5.2 (1.5-5.9) 6.2 (2.2-7.6) 7.1 (2.9-8.0)
Fan speed 5 steps, quiet and automatic Cooling
(Min.-Max.) Btu/h 17,700 (5,100-20,100) 21,200 (7,500-25,900) 24,200 (9,900-27,300)
Sound pressure level (H/L/SL) dB (A) 42/36/33 44/35/32 45/36/33 46/37/34 Capacity
Rated kW 6.5 (1.5-8.0) 7.2 (2.2-9.0) 8.5 (2.9-9.7)
Dimensions (H x W x D) mm 290 x 1,050 x 250 Heating
(Min.-Max.) Btu/h 22,200 (5,100-27,300) 24,600 (7,500-30,700) 29,000 (9,900-33,100)
Machine weight kg 12 Power supply 1 phase, 220-240 V/220-230 V, 50/60 Hz
Outdoor unit RKD42HVMV RKD50HVMV RKD60HVMV RKD71HVMV Cooling 7.4 9.6 11.9
Casing colour Ivory white Running current Rated A
Heating 8.5 9.7 11.8
Type Hermetically sealed swing type Cooling Rated 1,600 (450-2,300) 2,100 (630-3,210) 2,600 (720-3,350)
Compressor Power consumption W
Motor output W 600 1,500 1,900 Heating (Min.-Max.) 1,840 (410-2,800) 2,120 (570-3,230) 2,580 (660-3,490)
Refrigerant charge (R-22) kg 1.10 1.00 1.50 1.60 CSPF 5.07 4.50 3.85
Sound pressure level (H/SL) dB (A) 49/44 49/44 50/46 53/49 Indoor unit FTXD50HVMV FTXD60HVMV FTXD71HVMV
Dimensions (H x W x D) mm 550 x 765 x 285 735 x 825 x 300 Front panel colour White
Machine weight kg 35 43 47 53 Cooling m3/min 16.8 (593) 17.5 (618) 18.3 (646)
Operation range CDB 19.4 to 46 Airflow rate (H)
Heating (cfm) 17.5 (618) 18.7 (660) 19.8 (699)
Liquid 6.4 9.5 Fan speed 5 steps, quiet and automatic
Piping connections Gas mm 12.7 15.9 Cooling 44/35/32 45/36/33 46/37/34
Sound pressure dB (A)
Drain 18.0 level (H/L/SL) Heating 42/33/30 44/35/32 46/37/34
Max. piping length 25 30 Dimensions (H x W x D) mm 290 x 1,050 x 238
m
Max. height difference 15 20 Machine weight kg 12
Outdoor unit RXD50HVMV RXD60HVMV RXD71HVMV
Casing colour Ivory white
Measurement conditions Type Hermetically sealed swing type
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; piping length 7.5 m. Compressor
Motor output W 1,500 1,900
2. Sound pressure levels are based on the temperature condition 1. above. These are anechoic values. These values are normally somewhat higher during actual
operation as a result of ambient conditions.
Refrigerant charge (R-22) kg 1.25 1.80
3. CSPF is based on TCVN 7830: 2012 conditions. Sound pressure Cooling 47/44 49/46 52/49
level (H/SL) dB (A)
Heating 48/45 49/46 52/49
Dimensions (H x W x D) mm 735 x 825 x 300
Machine weight kg 49 55 57
Cooling CDB 5 to 46
Operation range
Heating CWB 15 to 18
Liquid 6.4 9.5
Piping connections Gas mm 12.7 15.9
Drain 18.0
Max. piping length 30
m
Max. height difference 20
Note: The above values are based on operation with a 220 V, 50 Hz power supply.
Measurement conditions
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; piping length 7.5 m.
2. Heating capacity is based on: indoor temp. 20 CDB; outdoor temp. 7 CDB, 6 CWB; piping length 7.5 m.
3. Sound pressure levels are based on the temperature conditions 1. and 2. above. These are anechoic conversion values. These values are normally somewhat higher
during actual operation as a result of ambient conditions.
4. CSPF is based on TCVN 7830: 2012 conditions.

19 20
Controller Controller

Wireless Remote Controller FTKS25/35G, FTXS25/35G, FTKD25/35H and FTXD25/35H Wireless Remote Controller FTKS50/60/71G and FTKD42/50/60/71H

Vertical Auto-Swing
(up and down)
Econo Mode Econo Mode
Selects fan speed and Selects fan speed and
Indoor Unit Quiet Operation On/Off Switch On/Off Switch
Indoor Unit Quiet Operation
Sets room temperature Sets room temperature
Selects mode: automatic, cooling, * Selects mode: cooling, dry,
Inverter Powerful Operation fan-only operation Inverter Powerful Operation
heating, dry, fan-only operation
Outdoor Unit Quiet Operation Outdoor Unit Quiet Operation Vertical Auto-Swing
(up and down)
Mould-Proof Operation Intelligent Eye Horizontal Auto-Swing
Intelligent Eye (left and right)
Comfort Airflow Mode
Cancels On/Off Timer Cancels On/Off Timer
24-Hour On Timer 24-Hour On Timer
Sets clock
24-Hour Off Timer
24-Hour Off Timer and Night Set Mode Sets timer
and Night Set Mode
Sets timer

Sets clock

*Available with the heat pump type.

Options
Wireless Remote Controller FTXS50/60/71G and FTXD50/60/71H
Indoor unit
FTKS25/35G FTKS50/60/71G FTXS25/35G FTXS50/60/71G
No. Item FTKD25/35H FTKD50/60/71H FTXD25/35H FTXD50/60/71H
1 5-room centralised controller *1 KRC72A
2 Wiring adaptor for time clock/remote controller KRP413AB1S
(Normal open pulse contact/normal open contact) *2
Vertical Auto-Swing 3 Titanium apatite photocatalytic air-purifying filter *3 KAF970A46
(up and down) Home Leave Operation 4 Air-purifying Filter with Photocatalytic Deodorising *3
KAF971B42
Function
Selects fan speed and On/Off Switch 5 Remote controller loss prevention with chain KKF917A4
Indoor Unit Quiet Operation Notes: *1. A wiring adaptor (KRP413AB1S) is also required for each indoor unit.
Sets room temperature *2. The time clock and other devices should be obtained locally.
Selects mode: automatic, cooling, * *3. The filter is a standard accessory. It should be replaced approximately every 3 years.
Inverter Powerful Operation
heating, dry, fan-only operation
Outdoor Unit Quiet Operation
Outdoor unit
Intelligent Eye No. Item RK(X)S25/35G RK(X)S50/60G RK(X)S71G RKD25/35/42H RXD25/35H RKD50/60/71H RXD50/60/71H
Horizontal Auto-Swing 1 Air direction adjustment grille KPW937A4 KPW945A4 KPW937A4 KPW945A4
(left and right) 2 Drain plug KKP937A4 *1 KKP945A4 KKP937A4 *1
Cancels On/Off Timer Note: *1. One set includes 5 pieces for 5 units.

24-Hour On Timer
24-Hour Off Timer Control system
and Night Set Mode
No. Item FTKS-G, FTXS-G, FTKD-H and FTXD-H
Sets timer 1 Central remote controller *1 DCS302CA61
2 Unified On/Off controller *1 DCS301BA61
Sets clock 3 Schedule timer *1 DST301BA61
4 Interface adaptor for DIII-NET use KRP928BB2S
Note: *1. Interface adaptor for DIII-NET use (KRP928BB2S) is also required for each indoor unit.
*Available with the heat pump type.
Specifications are subject to change.

21 22
Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
Read the User's Manual carefully before using this product. The User's Manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.

Cautions on product corrosion


1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you eed
n to install
the outdoor unit close to the sea shore, contact your local distributor.

Dealer
HEAD OFFICE
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi, Kita-ku, Osaka, 530-8323 Japan
CON
 G TY COÅ PHANÀ VIETÄ KIM
VAN
Ê PHON
Ø G CHÍNH
Tanàg 14-15, toaø nhaø Nam A,Ù 201-203 Cacùh Manïg Thanùg 8, P.4, Q.3, TP.HCM
Tel: (08) 62 504 888 Fax: (08) 62 504 999
CHI NHAN
Ù H HAØ NOIÄ
Tanàg 12, toaø nhaø Ocean Park Tower, 1 Ñaoø Duy Anh, Quanä Ñonág Ña, Haø Noiä
Tel: (04) 35 657 677 Fax: (04) 35 657 688
CHI NHAN
Ù H ÑAØ NAN
Ü G
Tanàg 12, Loâ A2.1, Ñöônøg 30/4, P. Hoaø Cöônøg Bacé, Q. Haiû Chauâ, TP. Ñaø Nanüg
Tel: (0511) 362 4250 Fax: (0511) 362 4251
www.daikin.com.vn

Specifications, designs and other content appearing in this brochure are current as of October 2013 but subject to change without notice. c All rights reserved

Você também pode gostar