Você está na página 1de 24

HD/T-Series

Pneumatic & Hydraulic Actuators


for Heavy Duty Service

Balanced
Scotch-Yoke Design

Manual Overrides

Guaranteed Minimum
Torques

Variety of Trims

No External Tie Bars

Bi-directional
Travel Stops

Internally Coated
To Resist Corrosion
Design and Construction
9

Typical HD-Series
Pneumatic Unit

Introduction Bettis’ new G-Series continues the reduces the chance of injury to
torque range to 6,000,000 lb-in. operating personnel. It is designed
Bettis HD/T-Series pneumatic and
for use in hostile environments and
hydraulic actuators are ideally suited Operating Pressures is adaptable for hydraulic and sub-
for operating ball, butterfly, plug
The HD-Series operates at pneu- merged applications.
valves, dampers and other 90
matic pressures up to 250 PSIG (17 2 Scotch-Yoke Mechanism. A
degree turn devices. The HD/T-
BAR) or hydraulic pressures up to balanced scotch-yoke mechanism
Series actuators provide a practical
3000 PSIG (207 BAR). The T-Series provides optimum torque output
and reliable method for opening and
operates at pneumatic pressures up and maintenance simplicity by
closing valves by remote control
to 200 PSIG (14 BAR). Consult fac- transforming the linear travel of
without the need for expensive and
tory for hydraulic applications. the piston into a 90 degree rotat-
unnecessary gearing, hydraulic
pumps or other motor driven devices. Temperature Ranges ing movement.
All HD/T-Series heavy duty actua- 3 Journal Bearings. Large journal
Torque Ranges bearings in the housing and cover
tors are designed for operating tem-
The HD-Series double-acting assure proper alignment of the
peratures of -20°F to +200°F(-29°C
actuators are available with guaran- yoke and eliminate side thrust on
to +93°C). Optional low temperature
teed minimum output torques to the valve stem. Yoke journal bear-
trim allows continuous operation
50,331 lb-in (5,687 Nm). Fail safe ing surfaces and piston rods are
from -50°F to +150°F (-46°C to
spring-return models produce guar- coated with a baked on dry film
+66°C). High temperature trim pro-
anteed minimum spring ending lubricant and corrosion inhibitor for
vides operational capabilities from
torques to 18,044 lb-in (2,039 Nm). extended service life.
0°F to +350°F (-18°C to +177°C).
The T-Series offers guaranteed 4 Dual Rod Bushings. Bronze piston
minimum output torque to 104,000 HD/T Mechanical Components rod bushings support and guide the
lb-in (11,752 Nm) for double-acting 1 Enclosed Housing. The totally piston rod, preventing contact
units and guaranteed minimum enclosed housing protects all mov- between the piston and cylinder, thus
spring ending torques to 56,000 lb-in ing parts, minimizes the possibility minimizing wear.
(6,328 Nm) for spring-return units. of component misalignment and
Typical T-Series Pneumatic Unit

11
12

2 4

10

1 7
3
5 Bi-directional Travel Stops. Travel actuators. Xylan™ bonds to the T-Series Mechanical
stops are an integral part of the actu- chemically prepared surface of the Components
ator allowing 80° to 100° total travel steel cylinder so effectively that,
adjustment. Extended travel stops unlike other coatings, cracking and 10 Internal Pneumatic Cylinder Tie
are optional. flaking are virtually eliminated. This Bars. The T-Series, a powerful
fluoropolymer coating is highly heavy-duty actuator, incorporates
+50 -50
resistant to abrasion, thermal shock two internal cylinder tie rods. These
and provides excellent lubricity and rods guide the piston in the cylinder
low friction properties. Corrosive bore, preventing metal-to-metal con-
100%
properties of salts and other chemi- tact between the piston and cylin-
90%
cals normally found in the atmos- der. This piston guiding mechanism
80% phere or instrument air supply sys- minimizes side thrust and loss of
tem will not adversely affect its per- efficiency due to internal deflection.
-50 formance. Consult factory for T-Series 11 Track Guide. Another design fea-
+50 hydraulic cylinder internal coatings. ture of the T-Series includes a preci-
sion machined guiding track. This
9 Spring Cartridge. Spring-return
6 Vent/Fill Plug. A vent/fill plug pre- track prevents piston rod deflection
models can be assembled to rotate
vents overpressurization while thereby increasing efficiency and
clockwise or counterclockwise on
resisting water ingress. extends the life of seals and
the loss of operating pressure.
bearings.
7 Piston Seal(s). The pressure ener- Spring-return models are furnished
gized resilient piston seal(s) provide with “service safe” welded spring 12 Yoke Pin Roller Bearings. The
exceptional life and minimize cylinder cartridges or cylinders. The spring yoke pin has hardened, steel roller
wear. assembly can be safely changed or bearings which move within the
replaced in the field without the use track guide and absorb bending
8 Xylan Cylinder Coating. The stan- moments generated by the scotch-
dard internal coating on all HD/T- of special tools.
yoke mechanism.
Series pneumatic and HD hydraulic
Operating Principle

M1

2
M
Scotch-Yoke Mechanism
A balanced scotch-yoke mechanism required to efficiently operate most (torque output at the shortest moment
produces torque that closely matches quarter-turn valves. arm length).
the requirements of most quarter-turn As the piston moves, the length of This amplification and efficiency of
valves. Unlike other methods, such as the moment arm is changing constant- torque output allows the use of a small-
a crank arm that produces its lowest ly. Because the effective moment arm er piston, shorter moment arm and
torque at the start and the end of each is longest at the start and the end of lower operating pressures than many
stroke, the balanced scotch-yoke pro- the stroke (M2), the start torque (torque other mechanisms. Bettis guarantees all
duces its highest torque at the start output at the start and the end of a published torque outputs as minimum
and the end of each stroke, providing stroke) approaches twice the magni- values. With Bettis, you know what you
maximum torque precisely where it is tude of the minimum torque (M1) are getting for your investment.

Available Overrides*
Actuator Series
Manual Overrides Mechanical Hydraulic
Bettis actuators are available with HD Spring-Return M3 or M3HW M11
a variety of manual overrides HD Double-Acting Wrench, M3 or M3HW M11
designed to deliver full rated torque T Spring-Return M3 or M3HW (T3 only) M11
output without assistance from an T Double-Acting M (T3 only), M3 or M3HW M11
external power source.
–M Internal Manual (enclosed with declutching feature as standard)
– M3 Jackscrew (mechanically locks actuator in position)
– M3HW Jackscrew with handwheel
– M11 Manual Hydraulic Piston Pump with directional control valve
Mechanical Overrides *Consult factory for other types of overrides and override systems.
On smaller HD-Series double-act-
ing actuators, a shaft can be extend- Hydraulic Overrides
ed through the top of the housing and Bettis provides user friendly and manual override systems for both
is easily operated with a simple hand dependable self contained hydraulic double-acting and spring-return actu-
wrench. All HD-Series and most T- overrides that do not require a ators are available with bi-directional
Series models can be furnished with hydraulic power source. Power is pro- speed control during manual and
jackscrew(s) as an integral part of the vided by operation of a local manual power operation.
unit for hand-wheel or wrench opera- hydraulic hand pump. Hydraulic
tion.

Trim Options
For special applications and/or less steel hardware and special The N-Series is specifically designed
extreme environments, Bettis engi- corrosion resistant exterior coatings for nuclear power plant installations
neers have developed a wide variety for offshore applications, high cycle and meets the rigid design criteria of
of optional trims with special design or high speeds, controlled hardness the nuclear power industry.
criteria. Trim options include: high and metals and no copper or yellow met- Consult Bettis for more information
low temperature applications, stain- als for hydrogen sulfide atmospheres. on specific trim requirements.
Typical Specifications

The following information may be 4. The actuator shall utilize perma- 11. Actuator torque outputs shall be
used as a guide to compose specifi- nently lubricated, high perfor- guaranteed minimum values
cations for HD/T-Series actuators. mance yoke trunnion and piston auditable to type test of each
Bettis supplies actuators that meet or rod bearings. model. Torque testing and certifi-
exceed all the specifications stated 5. All bearings shall be sized and cation in accordance with
below. material selected to provide max- approved test procedures and
1. All double-acting actuators shall imum service life while perform- Q.A. processes are available on
be of the balanced scotch-yoke ing as sacrificial protectors of request.
design and be capable of produc- critical sealing and structural 12. The housing, spring cartridge
ing a torque output at both the components. and non-pressurized cylinder ele-
start and end positions (0 and 90 ments shall be environmentally
6. All bearing surfaces, including
degrees) of at least 1 1/2 times protected by a normally closed
cylinder, piston rods, tie rods and
the minimum torque output. vent system facilitating a positive
yoke shall be treated to provide a
Spring-return actuators shall be pressure purge during operation
durable, self-lubricating, corro-
of the balanced scotch-yoke per BSK 2661, if applicable.
sion and wear resistant surface.
design (i.e., air ending and spring
7. The actuator shall be permanent- 13. The position indicator shall be
ending as well as air start and
ly lubricated, devoid of lubrication indexable and highly visible
spring start shall have compara-
fittings and factory approved for from vertical or horizontal posi-
ble torque output values).
“zero” preventative maintenance tions for optional valve mounting
2. The actuator shall be effectively orientation.
practices.
sealed to prevent entry of water,
8. Factory installed instrument tub- 14. When a manual override is
atmospheric corrosive gases and
ing shall be type 316 stainless specified, it shall be capable of
airborne abrasive dust or water.
steel with corrosion resistant operating the actuator without
3. Power cylinders and spring car- assistance from the power gas
steel fittings.
tridges shall be mounted rigidly system, produce full rated
to the actuator housing using 9. The actuator travel stops shall
torque of the actuator and incor-
metal-to-metal interfaces and provide accurate adjustment, be
porate torque limiting devices to
weather tight seals. The power friction locked to prevent changes
minimize possibilities of valve
cylinder shall be retained by envi- due to vibration and impact
damage.
ronmentally protected internal tie loads, and be positively sealed.
15. The actuator shall be manufactur-
bars, machined threads on the 10. Bi-directional travel stops shall be
er’s standard design capable of
outside diameter of the cylinder, an integral part of the actuator
operating in a wide range of
or rigidly attached by external allowing 80° to 100° total travel
applications, including corrosive
bolting to the main housing. adjustment. These travel stops
atmospheres, without addition of
External tie bars or brace rods on shall be capable of stalling the
special trim equipment.
the pneumatic power cylinder are actuators maximum torque output.
prohibited.
Ordering / Model Designation

Spring-Return Pneumatic Example

HD 7 32 SR 80 – M3HW – CW
Headquarters
P.O. Box 508 Actuator fail mode (cw or ccw)
Waller, TX 77484 Type of manual override (e.g., manual
U.S.A. override jackscrew with handwheel)
Tel: 281/463-5100 Spring Return (e.g., 80 PSIG nominal
Fax: 281/463-5103 operating pressure)
E-Mail: marketing@bettis.com
Website: www.bettis.com Number of working pistons (1 or 2)

Bettis UK Ltd. Nominal moment arm (e.g., 3.0 inches)


Brunel Way
Nominal cylinder size (inches)
Fareham, Hampshire PO15 5SA
England Heavy Duty Series
Tel: 0148-988-5333
Fax: 0148-988-5200
Tlx: 47493 Double-Acting Pneumatic Example

Bettis Canada Ltd.


4112-91 A Street T 3 12 – 10 – M11
Edmonton, Alberta T6E 5V2
Canada Type of manual override (e.g., manual
Tel: 403/450-3600 hydraulic piston pump)
Fax: 403/450-1400
Bettis France Temperature trim (e.g., high temp)
30/36 Allee du Plateau
93250 Villemomble
France Nominal cylinder size (inches)
Tel: 48 12 26 10
Fax: 48 12 26 19 Nominal moment arm (e.g., 3.0 inches)

Bettis International Sales Offices: T-Series (track guide)


Calgary, Canada
Dubai, U.A.E.
Rheinberg, Germany
New Bombay, India Optional Accessories
Singapore
Montreal, Canada
Bettisystems™
Bettis has pre-engineered and docu-
mented a series of commonly
required control systems. These
approved systems utilize standard
components, reduce lead times, and
simplify purchasing, installation and
startup. We can design a custom
Bettisystem™ for you, please contact
the factory with your specifications.

Catalog #30.00-2
Important: Due to Bettis’ continuing commitment to engineered ©1998. Bettis Corporation. All rights reserved.
product advancement, data presented herein is subject to change. BET97007/5m/1/98
Torque Ratings – HD-Series (Hydraulic)
All Published Torques are Guaranteed Minimum Values.

Double-Acting Actuators
HD-Series
Operating Pressure (Bar)
Actuator See Bettis’
Model Definitions 35 50 65 70 80 90 100 120 140 160 175
Pressure Torque Output Start/Min./End (Nm)
H251.5 Start/End 554 720 775 886 997 1107 1329 1550 1772 1938
Minimum 324 421 453 518 582 647 777 906 1035 1132
H352.1 Start/End 1055 1508 1960 2111 2412 2714 3015 3618 4221 4824 5277
Minimum 617 881 1145 1233 1410 1586 1762 2115 2467 2819 3084

Spring-Return Actuators
HD-Series
Operating Pressure (Bar)
Actuator Spring Torque
Model Start/Min./End 35 50 65 70 80 90 100 120 140 160 175 200
(Nm) Pressure Torque Output Start/Min./End (Nm)
H251.5-SR540 Start 178 262 426 590 645 754 863 973 1191 1410 1628 1792 2066
Min. 83 131 229 327 359 424 488 553 683 812 941 1038 1200
End 109 185 349 513 568 677 787 896 1114 1333 1552 1715 1989
H251.5-SR560 Start 268 201 365 529 584 693 802 912 1130 1349 1567 1731 2005
Min. 125 80 180 278 310 375 441 506 635 765 894 991 1153
End 164 86 250 414 469 578 687 797 1015 1234 1452 1616 1890
H251.5-SR580 Start 347 312 476 530 639 749 858 1077 1295 1514 1678 1951
Min. 162 135 235 268 333 398 463 593 723 852 949 1111
End 213 163 327 381 490 600 709 928 1146 1365 1529 1802
H251.5-SR5100 Start 434 418 473 582 692 801 1019 1238 1457 1621 1894
Min. 202 187 220 286 351 416 546 677 807 904 1066
End 264 231 286 395 504 614 832 1051 1269 1433 1707
H251.5-SR5125 Start 550 506 615 724 943 1162 1380 1544 1817
Min. 256 221 288 354 484 614 745 842 1005
End 333 267 376 486 704 923 1141 1305 1579
H251.5-SR5150 Start 658 540 649 868 1086 1305 1469 1742
Min. 307 224 292 425 555 685 783 945
End 401 256 365 584 802 1021 1185 1458
H251.5-SR780 Start 689 578 796 1015 1233 1397 1671
Min. 322 231 366 498 629 726 889
End 422 251 470 688 907 1071 1344
H251.5-SR7100 Start 863 884 1102 1266 1540
Min. 404 390 522 622 785
End 529 475 694 858 1131
H251.5-SR7125 Start 1070 949 1113 1386
Min. 500 391 493 659
End 655 441 605 878
H251.5-SR7150 Start 1268 1250
Min. 589 537
End 766 636
H352.1-SR740 Start 1006 875 1322 1470 1768 2066 2363 2958 3554 4149 4595 5339
Min. 428 259 580 671 851 1030 1208 1562 1917 2271 2537 2979
End 501 259 705 854 1151 1449 1747 2342 2937 3532 3979 4723
H352.1-SR760 Start 1512 1459 1757 2055 2650 3245 3840 4287 5031
Min. 643 533 729 915 1275 1632 1987 2253 2696
End 754 533 831 1128 1723 2319 2914 3360 4104
H352.1-SR780 Start 2014 1745 2341 2936 3531 3977 4721
Min. 858 514 973 1340 1700 1970 2413
End 1007 514 1109 1705 2300 2746 3490
H352.1-SR7100 Start 2521 2626 3221 3668 4412
Min. 1074 1024 1400 1673 2123
End 1260 1085 1680 2126 2870
H352.1-SR7125 Start 3151 2847 3293 4037
Min. 1339 911 1282 1752
End 1567 911 1357 2101
Actuator Spring Torque Pressure Torque Output Start/Min./End (Nm)
Model Start/Min./End 35 50 65 70 80 90 100 120 140 160 175 200
(Nm) Operating Pressure (Bar)

10/98 HHM 1.01


Performance Data – HD-Series (Hydraulic)
Double-Acting Actuators
HD-Series
Maximum Maximum Allowable Approximate
Actuator Displacement Operating Working Weight of
Model Per Stroke Pressure (MOP)* Pressure (MAWP)** Actuator
(cu cm)▲ (Bar) (Bar) (kg)
H 251.5 147 207 207 31
H 352.1 393 207 276 62

Spring-Return Actuators
HD-Series
Maximum Maximum Allowable Approximate
Actuator Displacement Operating Working Weight of
Model Per Stroke Pressure (MOP)* Pressure (MAWP)** Actuator
(cu cm)▲ (Bar) (Bar) (kg)

H 251.5-SR540 147 207 207 50


H 251.5-SR560 147 207 207 52
H 251.5-SR580 147 207 207 53
H 251.5-SR5100 147 207 207 58
H 251.5-SR5125 147 207 207 59
H 251.5-SR5150 147 207 207 60
H 251.5-SR780 147 207 207 75
H 251.5-SR7100 147 207 207 76
H 251.5-SR7125 147 207 207 87
H 251.5-SR7150 147 207 207 88
H 352.1-SR740 393 207 276 112
H 352.1-SR760 393 207 276 119
H 352.1-SR780 393 207 276 132
H 352.1-SR7100 393 207 276 137
H 352.1-SR7125 393 207 276 147

NOTES:

▲ Maximum displacement required for calculating consumption per stroke. All HD-Series hydraulic
actuators have opposing hydraulic rams for both directions of travel.

* Maximum Operating Pressure (MOP) is the pressure required to produce the maximum rated torque
of the actuator.
** Maximum Allowable Working Pressure (MAWP) is the maximum static pressure that may be applied to
a fully stroked actuator against the travel stops.

10/98 HHM 2.01


Dimensions – HD-Series (Hydraulic) [mm]

Double-Acting

Model A B C D E F G H J K L M N P Q R S T U

H251.5 800.1 400.1 141.2 282.4 50.8 95.3 80.8 40.4 226.3 72.9 63.5 N/A 71.4 N/A 1/2-13 19.1 142.7 180.8 76.0

Double-Acting

Model A B C D

H352.1 936.8 468.4 69.85 127.0

The drawings herein are not certified engineering drawings. Please consult factory for certified dimensional drawings.

10/98 HHM 3.01


Dimensions – HD-Series (Hydraulic) [mm]

Spring-Return

Model A B C D E F G H J K L M N Q R S T U V W
HD 251.5-SR
560 1109.7
HD 251.5-SR
5150
HD 251-SR
5100 1256.5
HD 251-SR 400.1 141.2 282.4 50.8 95.3 80.8 40.4 226.3 72.9 63.5 N.A. 71.4 1/2-13 19.1 142.7 180.8 76.0 150.9 136.4
5125
HD 251-SR
580
HD 251-SR 1109.7
540

HD 251-SR
560

Spring-Return

Model A B
H352.1-SR
1520.7 962.0
740/760
H352.1-SR
1520.7 962.0
780/7100
H352.1-SR
1657.4 1098.6
7125/7150

The drawings herein are not certified engineering drawings. Please consult factory for certified dimensional drawings.

HHM 3.02 10/98


Torque Ratings – HD-Series (Pneumatic)
All Published Torques are Guaranteed Minimum Values.

Double-Acting Actuators
HD-Series
Operating Pressure (Bar)
Actuator See Bettis’
Model Definitions 3 4 5 6 7 8 9 10 12 14
Pressure Torque Output Start/Min./End (Nm)
HD 521 Start/End 335 447 559 670 782 894 1006 1117 1341 1564
Minimum 197 262 328 393 459 524 590 656 787 918
HD 721 Start/End 709 946 1182 1419 1655 1891 2128 2364
Minimum 400 533 667 800 934 1067 1200 1334
HD 722 Start/End 1452 1937 2421
Minimum 819 1092 1366
HD 731 Start/End 1005 1340 1675 2010 2345 2680 3015 3350 4020 4690
Minimum 538 717 896 1075 1254 1433 1613 1792 2150 2508
HD 732 Start/End 2062 2749 3437 4124 4811 5499 6186
Minimum 1129 1506 1882 2258 2635 3011 3387

Spring-Return Actuators
HD-Series
Operating Pressure (Bar)
Actuator Spring Torque
Model Start/Min./End 3 4 5 6 7 8 9 10 12 14
(Nm) Pressure Torque Output Start/Min./End (Nm)
HD 521-SR40 Start 176 217 328 440 552 664 775 887 999 1222 1446
Min. 82 103 169 235 301 367 432 498 563 694 826
End 108 141 252 364 476 588 699 811 923 1146 1370
HD 521-SR60 Start 264 268 380 492 603 715 827 939 1162 1386
Min. 123 121 188 254 319 385 451 517 648 779
End 162 155 266 378 490 602 713 825 1049 1272
HD 521-SR80 Start 342 327 439 550 662 774 886 1109 1333
Min. 159 144 211 278 344 409 475 607 738
End 210 180 292 403 515 627 739 962 1186
HD 521-SR100 Start 428 382 494 606 718 829 1053 1276
Min 198 164 231 298 364 430 562 693
End 261 198 309 421 533 645 868 1091
HD 521-SR125 Start 542 530 642 754 977 1201
Min. 250 235 302 369 501 633
End 329 295 407 518 742 965
HD 521-SR150 Start 650 680 903 1127
Min. 301 309 442 575
End 396 399 623 846
HD 521-SR200 Start 870 753 976
Min. 403 319 454
End 532 379 603
HD 721-SR40 Start 331 482 725 967 1210 1452 1695 1937 2180
Min. 147 224 361 498 635 771 908 1044 1181
End 201 323 566 808 1051 1293 1536 1778 2021
HD 721-SR60 Start 555 581 829 1078 1326 1575 1823 2072
Min. 246 244 386 527 667 807 946 1086
End 339 316 564 813 1061 1310 1558 1807
HD 721-SR80 Start 743 687 935 1184 1432 1681 1930 2427
Min. 330 275 419 560 700 840 980 1260
End 455 335 583 832 1080 1329 1578 2075
HD 721-SR100 Start 931 794 1043 1291 1540 1788 2285
Min. 413 306 451 593 734 874 1154
End 570 354 602 851 1099 1348 1845
Pressure Torque Output Start/Min./End (Nm)
Actuator Spring Torque
Model Start/Min./End 3 4 5 6 7 8 9 10 12 14
(Nm) Operating Pressure (Bar)

10/98 HPM 1.01


Torque Ratings – HD-Series (Pneumatic)
All Published Torques are Guaranteed Minimum Values.

Torques
Spring-Return Actuators
HD-Series (cont.)
Operating Pressure (Bar)
Actuator Spring Torque
Model Start/Min./End 3 4 5 6 7 8 9 10 12 14
(Nm) Pressure Torque Output Start/Min./End (Nm)
HD 721-SR125 Start 1070 1043 1273 1504 1964 2425
Min. 479 431 565 698 961 1223
End 655 535 765 996 1457 1917
HD 721-SR150 Start 1268 1138 1368 1829 2290
Min. 564 448 584 850 1113
End 766 524 754 1215 1675
HD 721-SR200 Start 2149 1806
Min. 909 599
End 1161 599
HD 722-SR40 Start 833 1020 1529 2038
Min. 337 412 705 993
End 416 510 1019 1528
HD 722-SR60 Start 1288 1249 1758 2267
Min. 522 442 744 1036
End 644 461 970 1479
HD 722-SR80 Start 1665 1530 2039
Min. 674 510 826
End 831 511 1020
HD 722-SR100 Start 2126 2266
Min. 861 855
End 1061 964
HD 732-SR40 Start 1085 1352 2023 2694 3365 4036 4707 5378 6049
Min. 439 551 936 1316 1694 2072 2449 2826 3202
End 541 686 1357 2028 2699 3370 4041 4712 5383
HD 732-SR60 Start 1631 1690 2361 3032 3703 4374 5045 5716
Min. 660 626 1020 1403 1783 2162 2539 2917
End 814 690 1361 2032 2703 3374 4045 4716
HD 732-SR80 Start 2226 2077 2764 3451 4139 4826 5513
Min. 882 699 1102 1489 1871 2251 2630
End 1113 716 1403 2090 2778 3465 4152
HD 732-SR100 Start 2721 2363 3034 3705 4376 5047
Min. 1103 700 1176 1568 1954 2336
End 1360 701 1372 2043 2714 3385
HD 732-SR125 Start 3399 3302 3973 4644 5986
Min. 1375 1166 1572 1964 2732
End 1691 1213 1884 2555 3897
HD 732-SR150 Start 4090 4218 5560
Min. 1656 1557 2349
End 2039 1711 3053
Pressure Torque Output Start/Min./End (Nm)
Actuator Spring Torque
Model Start/Min./End 3 4 5 6 7 8 9 10 12 14
(Nm) Operating Pressure (Bar)

HPM 1.02 10/98


Performance Data – HD-Series (Pneumatic)
Double-Acting Actuators
HD-Series
Maximum Maximum Allowable Approximate With M3 With M3HW With M11
Actuator Displacement Operating Working Weight of Add Add Add
Model Per Stroke Pressure (MOP)* Pressure (MAWP)** Actuator (kg)† (kg)† (kg)†
(cu cm)▲ (Bar) (Bar) (kg)
HD 521 2196 14 14 36 5 11 34
HD 721 4277 10.5 14 45 5 11 43
HD 722 7980.5 5 8.5 57 5 11 —
HD 731 5276.6 14 14 74 5 11 45
HD 732 10193 10.5 14 94 5 11 —

Spring-Return Actuators
HD-Series
Maximum Maximum Allowable Approximate With M3 With M3HW With M7
Actuator Displacement Operating Working Weight of Add Add Add
Model Per Stroke Pressure (MOP)* Pressure (MAWP)** Actuator (kg)† (kg)† (kg)†
(cu cm)▲ (Bar) (Bar) (kg)
HD 521-SR40 2196 14 14 48 2 5 29
HD 521-SR60 2196 14 14 49 2 5 29
HD 521-SR80 2196 14 14 50 2 5 29
HD 521-SR100 2196 14 14 55 2 5 29
HD 521-SR125 2196 14 14 56 2 5 29
HD 521-SR150 2196 14 14 57 2 5 29
HD 521-SR200 2196 14 14 62 2 5 29
HD 721-SR40 4277 12.5 14 68 2 5 39
HD 721-SR60 4277 13.5 14 71 2 5 39
HD 721-SR80 4277 14 14 73 2 5 39
HD 721-SR100 4277 14 14 74 2 5 39
HD 721-SR125 4277 14 14 84 2 5 39
HD 721-SR150 4277 14 14 85 2 5 39
HD 721-SR200 4277 14 14 92 2 5 39
HD 722-SR40 7981 6 8.5 98 2 5 —
HD 722-SR60 7981 8 8.5 104 2 5 —
HD 722-SR80 7981 9 10.5 107 2 5 —
HD 722-SR100 7981 10 12 113 2 5 —
HD 732-SR40 10193 11 14 125 2 5 —
HD 732-SR60 10193 12 14 132 2 5 —
HD 732-SR80 10193 13 14 143 2 5 —
HD 732-SR100 10193 14 14 148 2 5 —
HD 732-SR125 10193 14 14 160 2 5 —
HD 732-SR150 10193 14 14 166 2 5 —

NOTES:

† Manual Overrides
M3 Jackscrew
M3HW Jackscrew and handwheel
M11 Piston pump assembly including hydraulic cylinder
M7 Piston pump assembly including hydraulic cylinder

▲ Maximum volume including cavity required for calculating consumption per stroke.

* Maximum Operating Pressure (MOP) is the pressure required to produce the maximum rated torque
of the actuator.
** Maximum Allowable Working Pressure (MAWP) is the maximum static pressure that may be applied to
a fully stroked actuator against the travel stops.

10/98 HPM 2.01


Dimensions – HD-Series (Pneumatic) [mm]

Double-Acting

Model A B C D E F G H J K L M N P Q R S T U
521 843.0 460.2 136.7 151.6 147.6
.500-13
721 851.7 141.2 282.4 81.0 40.4 226.3 73.2 63.5 71.4 63.60 UNC 19.1 142.7 193.5 73.2
469.1 174.8
722 938.3
190.5 206.2
731 1006.3
566.7 173.0 345.9 103.1 51.6 300.0 91.9 85.9 193.5 90.4 82.55 .750-10 25.4 184.2 212.9 95.3
732 1133.3 UNC

Double-Acting with M4 Hydraulic Override

Model A B C D E F G H J K L M N P Q R S T U V
521-M4 920.8 460.2 136.7 150.9
141.2 282.4 81.0 40.4 226.3 73.2 63.5 71.4 63.60 .500-13 19.1 142.7 73.2 503.2
721-M4 938.3 469.1 349.3 UNC 522.2
190.5 215.9
731-M4 1133.3 566.7 173.0 345.9 103.1 51.6 300.0 91.9 85.9 90.4 82.55 .750-10 25.4 184.2 95.3 599.9
UNC

Mounting Dimensions (View A-A) For All HD-Series Actuators


(Dimensions G, H, P, Q, R and S)

Certified dimensional drawing available on request. Contact factory with correct model designation and serial number.

10/98 HPM 3.01


Dimensions – HD-Series (Pneumatic) [mm]

Spring-Return

Spring Size
40 60 80 100 120 150 200
Model Dimension A B C D E F G
521-SR 1125.5 1125.5 1125.5 1272.3 1272.3 1272.3 1353.3 136.7 151.6
382.5
721-SR 1154.2 1154.2 1154.2 1154.2 1273.0 1273.0 — 141.2 282.4 81.0
722-SR 1296.9 1296.9 1398.5 1398.5 — — — 469.1 190.5 206.2
732-SR 1541.5 1541.5 1677.9 1677.9 1782.8 1782.8 — 566.7 173.0 345.9 103.1

Model H J K L M N P Q THD. R S T U
521-SR 147.6
721-SR 40.4 226.3 73.2 63.5 71.4 63.60 .500-13 UNC 19.1 142.7 193.5 73.2
174.8
722-SR
732-SR 51.6 300.0 91.9 85.9 193.5 90.4 82.55 .750-10 UNC 25.4 184.2 212.9 95.3

Spring-Return with M7 Hydraulic Override

Spring Size
40 60 80 100 120 150 200
Model Dimension A B C D E F G
521-SR-M7 1203.5 1203.5 1203.5 1350.3 1350.3 1350.3 1431.0 136.7 151.6
382.5 141.2 282.4 81.0
721-SR-M7 1240.5 1240.5 1240.5 1240.5 1359.7 1359.7 —
190.5 206.2
732-SR-M7 1541.5 1541.5 1677.9 1677.9 1782.8 1782.8 — 566.7 173.0 345.9 103.1

Model H J K L M N P Q THD. R S T U V
521-SR-M7 — 913.6
40.4 226.3 73.2 63.5 71.4 63.60 .500-13 UNC 19.1 142.7 762.0 73.2
721-SR-M7 — 926.3
732-SR-M7 51.6 300.0 91.9 85.9 — 90.4 82.55 .750-10 UNC 25.4 184.2 — 95.3 954.8

Certified dimensional drawing available on request. Contact factory with correct model designation and serial number.

HPM 3.02 10/98


Torque Ratings – HD-Series (Hydraulic)
All Published Torques are Guaranteed Minimum Values.

Double-Acting Actuators
HD-Series
Operating Pressure (Bar)
Actuator See Bettis’
Model Definitions 35 50 65 70 80 90 100 120 140 160 175
Pressure Torque Output Start/Min./End (Nm)
H251.5 Start/End 554 720 775 886 997 1107 1329 1550 1772 1938
Minimum 324 421 453 518 582 647 777 906 1035 1132
H352.1 Start/End 1055 1508 1960 2111 2412 2714 3015 3618 4221 4824 5277
Minimum 617 881 1145 1233 1410 1586 1762 2115 2467 2819 3084

Spring-Return Actuators
HD-Series
Operating Pressure (Bar)
Actuator Spring Torque
Model Start/Min./End 35 50 65 70 80 90 100 120 140 160 175 200
(Nm) Pressure Torque Output Start/Min./End (Nm)
H251.5-SR540 Start 178 262 426 590 645 754 863 973 1191 1410 1628 1792 2066
Min. 83 131 229 327 359 424 488 553 683 812 941 1038 1200
End 109 185 349 513 568 677 787 896 1114 1333 1552 1715 1989
H251.5-SR560 Start 268 201 365 529 584 693 802 912 1130 1349 1567 1731 2005
Min. 125 80 180 278 310 375 441 506 635 765 894 991 1153
End 164 86 250 414 469 578 687 797 1015 1234 1452 1616 1890
H251.5-SR580 Start 347 312 476 530 639 749 858 1077 1295 1514 1678 1951
Min. 162 135 235 268 333 398 463 593 723 852 949 1111
End 213 163 327 381 490 600 709 928 1146 1365 1529 1802
H251.5-SR5100 Start 434 418 473 582 692 801 1019 1238 1457 1621 1894
Min. 202 187 220 286 351 416 546 677 807 904 1066
End 264 231 286 395 504 614 832 1051 1269 1433 1707
H251.5-SR5125 Start 550 506 615 724 943 1162 1380 1544 1817
Min. 256 221 288 354 484 614 745 842 1005
End 333 267 376 486 704 923 1141 1305 1579
H251.5-SR5150 Start 658 540 649 868 1086 1305 1469 1742
Min. 307 224 292 425 555 685 783 945
End 401 256 365 584 802 1021 1185 1458
H251.5-SR780 Start 689 578 796 1015 1233 1397 1671
Min. 322 231 366 498 629 726 889
End 422 251 470 688 907 1071 1344
H251.5-SR7100 Start 863 884 1102 1266 1540
Min. 404 390 522 622 785
End 529 475 694 858 1131
H251.5-SR7125 Start 1070 949 1113 1386
Min. 500 391 493 659
End 655 441 605 878
H251.5-SR7150 Start 1268 1250
Min. 589 537
End 766 636
H352.1-SR740 Start 1006 875 1322 1470 1768 2066 2363 2958 3554 4149 4595 5339
Min. 428 259 580 671 851 1030 1208 1562 1917 2271 2537 2979
End 501 259 705 854 1151 1449 1747 2342 2937 3532 3979 4723
H352.1-SR760 Start 1512 1459 1757 2055 2650 3245 3840 4287 5031
Min. 643 533 729 915 1275 1632 1987 2253 2696
End 754 533 831 1128 1723 2319 2914 3360 4104
H352.1-SR780 Start 2014 1745 2341 2936 3531 3977 4721
Min. 858 514 973 1340 1700 1970 2413
End 1007 514 1109 1705 2300 2746 3490
H352.1-SR7100 Start 2521 2626 3221 3668 4412
Min. 1074 1024 1400 1673 2123
End 1260 1085 1680 2126 2870
H352.1-SR7125 Start 3151 2847 3293 4037
Min. 1339 911 1282 1752
End 1567 911 1357 2101
Actuator Spring Torque Pressure Torque Output Start/Min./End (Nm)
Model Start/Min./End 35 50 65 70 80 90 100 120 140 160 175 200
(Nm) Operating Pressure (Bar)

10/98 HHM 1.01


Performance Data – HD-Series (Hydraulic)
Double-Acting Actuators
HD-Series
Maximum Maximum Allowable Approximate
Actuator Displacement Operating Working Weight of
Model Per Stroke Pressure (MOP)* Pressure (MAWP)** Actuator
(cu cm)▲ (Bar) (Bar) (kg)
H 251.5 147 207 207 31
H 352.1 393 207 276 62

Spring-Return Actuators
HD-Series
Maximum Maximum Allowable Approximate
Actuator Displacement Operating Working Weight of
Model Per Stroke Pressure (MOP)* Pressure (MAWP)** Actuator
(cu cm)▲ (Bar) (Bar) (kg)

H 251.5-SR540 147 207 207 50


H 251.5-SR560 147 207 207 52
H 251.5-SR580 147 207 207 53
H 251.5-SR5100 147 207 207 58
H 251.5-SR5125 147 207 207 59
H 251.5-SR5150 147 207 207 60
H 251.5-SR780 147 207 207 75
H 251.5-SR7100 147 207 207 76
H 251.5-SR7125 147 207 207 87
H 251.5-SR7150 147 207 207 88
H 352.1-SR740 393 207 276 112
H 352.1-SR760 393 207 276 119
H 352.1-SR780 393 207 276 132
H 352.1-SR7100 393 207 276 137
H 352.1-SR7125 393 207 276 147

NOTES:

▲ Maximum displacement required for calculating consumption per stroke. All HD-Series hydraulic
actuators have opposing hydraulic rams for both directions of travel.

* Maximum Operating Pressure (MOP) is the pressure required to produce the maximum rated torque
of the actuator.
** Maximum Allowable Working Pressure (MAWP) is the maximum static pressure that may be applied to
a fully stroked actuator against the travel stops.

10/98 HHM 2.01


Dimensions – HD-Series (Hydraulic) [mm]

Double-Acting

Model A B C D E F G H J K L M N P Q R S T U

H251.5 800.1 400.1 141.2 282.4 50.8 95.3 80.8 40.4 226.3 72.9 63.5 N/A 71.4 N/A 1/2-13 19.1 142.7 180.8 76.0

Double-Acting

Model A B C D

H352.1 936.8 468.4 69.85 127.0

The drawings herein are not certified engineering drawings. Please consult factory for certified dimensional drawings.

10/98 HHM 3.01


Dimensions – HD-Series (Hydraulic) [mm]

Spring-Return

Model A B C D E F G H J K L M N Q R S T U V W
HD 251.5-SR
560 1109.7
HD 251.5-SR
5150
HD 251-SR
5100 1256.5
HD 251-SR 400.1 141.2 282.4 50.8 95.3 80.8 40.4 226.3 72.9 63.5 N.A. 71.4 1/2-13 19.1 142.7 180.8 76.0 150.9 136.4
5125
HD 251-SR
580
HD 251-SR 1109.7
540

HD 251-SR
560

Spring-Return

Model A B
H352.1-SR
1520.7 962.0
740/760
H352.1-SR
1520.7 962.0
780/7100
H352.1-SR
1657.4 1098.6
7125/7150

The drawings herein are not certified engineering drawings. Please consult factory for certified dimensional drawings.

HHM 3.02 10/98


Torque Ratings – HD-Series (Pneumatic)
All Published Torques are Guaranteed Minimum Values.

Double-Acting Actuators
HD-Series
Operating Pressure (Bar)
Actuator See Bettis’
Model Definitions 3 4 5 6 7 8 9 10 12 14
Pressure Torque Output Start/Min./End (Nm)
HD 521 Start/End 335 447 559 670 782 894 1006 1117 1341 1564
Minimum 197 262 328 393 459 524 590 656 787 918
HD 721 Start/End 709 946 1182 1419 1655 1891 2128 2364
Minimum 400 533 667 800 934 1067 1200 1334
HD 722 Start/End 1452 1937 2421
Minimum 819 1092 1366
HD 731 Start/End 1005 1340 1675 2010 2345 2680 3015 3350 4020 4690
Minimum 538 717 896 1075 1254 1433 1613 1792 2150 2508
HD 732 Start/End 2062 2749 3437 4124 4811 5499 6186
Minimum 1129 1506 1882 2258 2635 3011 3387

Spring-Return Actuators
HD-Series
Operating Pressure (Bar)
Actuator Spring Torque
Model Start/Min./End 3 4 5 6 7 8 9 10 12 14
(Nm) Pressure Torque Output Start/Min./End (Nm)
HD 521-SR40 Start 176 217 328 440 552 664 775 887 999 1222 1446
Min. 82 103 169 235 301 367 432 498 563 694 826
End 108 141 252 364 476 588 699 811 923 1146 1370
HD 521-SR60 Start 264 268 380 492 603 715 827 939 1162 1386
Min. 123 121 188 254 319 385 451 517 648 779
End 162 155 266 378 490 602 713 825 1049 1272
HD 521-SR80 Start 342 327 439 550 662 774 886 1109 1333
Min. 159 144 211 278 344 409 475 607 738
End 210 180 292 403 515 627 739 962 1186
HD 521-SR100 Start 428 382 494 606 718 829 1053 1276
Min 198 164 231 298 364 430 562 693
End 261 198 309 421 533 645 868 1091
HD 521-SR125 Start 542 530 642 754 977 1201
Min. 250 235 302 369 501 633
End 329 295 407 518 742 965
HD 521-SR150 Start 650 680 903 1127
Min. 301 309 442 575
End 396 399 623 846
HD 521-SR200 Start 870 753 976
Min. 403 319 454
End 532 379 603
HD 721-SR40 Start 331 482 725 967 1210 1452 1695 1937 2180
Min. 147 224 361 498 635 771 908 1044 1181
End 201 323 566 808 1051 1293 1536 1778 2021
HD 721-SR60 Start 555 581 829 1078 1326 1575 1823 2072
Min. 246 244 386 527 667 807 946 1086
End 339 316 564 813 1061 1310 1558 1807
HD 721-SR80 Start 743 687 935 1184 1432 1681 1930 2427
Min. 330 275 419 560 700 840 980 1260
End 455 335 583 832 1080 1329 1578 2075
HD 721-SR100 Start 931 794 1043 1291 1540 1788 2285
Min. 413 306 451 593 734 874 1154
End 570 354 602 851 1099 1348 1845
Pressure Torque Output Start/Min./End (Nm)
Actuator Spring Torque
Model Start/Min./End 3 4 5 6 7 8 9 10 12 14
(Nm) Operating Pressure (Bar)

10/98 HPM 1.01


Torque Ratings – HD-Series (Pneumatic)
All Published Torques are Guaranteed Minimum Values.

Torques
Spring-Return Actuators
HD-Series (cont.)
Operating Pressure (Bar)
Actuator Spring Torque
Model Start/Min./End 3 4 5 6 7 8 9 10 12 14
(Nm) Pressure Torque Output Start/Min./End (Nm)
HD 721-SR125 Start 1070 1043 1273 1504 1964 2425
Min. 479 431 565 698 961 1223
End 655 535 765 996 1457 1917
HD 721-SR150 Start 1268 1138 1368 1829 2290
Min. 564 448 584 850 1113
End 766 524 754 1215 1675
HD 721-SR200 Start 2149 1806
Min. 909 599
End 1161 599
HD 722-SR40 Start 833 1020 1529 2038
Min. 337 412 705 993
End 416 510 1019 1528
HD 722-SR60 Start 1288 1249 1758 2267
Min. 522 442 744 1036
End 644 461 970 1479
HD 722-SR80 Start 1665 1530 2039
Min. 674 510 826
End 831 511 1020
HD 722-SR100 Start 2126 2266
Min. 861 855
End 1061 964
HD 732-SR40 Start 1085 1352 2023 2694 3365 4036 4707 5378 6049
Min. 439 551 936 1316 1694 2072 2449 2826 3202
End 541 686 1357 2028 2699 3370 4041 4712 5383
HD 732-SR60 Start 1631 1690 2361 3032 3703 4374 5045 5716
Min. 660 626 1020 1403 1783 2162 2539 2917
End 814 690 1361 2032 2703 3374 4045 4716
HD 732-SR80 Start 2226 2077 2764 3451 4139 4826 5513
Min. 882 699 1102 1489 1871 2251 2630
End 1113 716 1403 2090 2778 3465 4152
HD 732-SR100 Start 2721 2363 3034 3705 4376 5047
Min. 1103 700 1176 1568 1954 2336
End 1360 701 1372 2043 2714 3385
HD 732-SR125 Start 3399 3302 3973 4644 5986
Min. 1375 1166 1572 1964 2732
End 1691 1213 1884 2555 3897
HD 732-SR150 Start 4090 4218 5560
Min. 1656 1557 2349
End 2039 1711 3053
Pressure Torque Output Start/Min./End (Nm)
Actuator Spring Torque
Model Start/Min./End 3 4 5 6 7 8 9 10 12 14
(Nm) Operating Pressure (Bar)

HPM 1.02 10/98


Performance Data – HD-Series (Pneumatic)
Double-Acting Actuators
HD-Series
Maximum Maximum Allowable Approximate With M3 With M3HW With M11
Actuator Displacement Operating Working Weight of Add Add Add
Model Per Stroke Pressure (MOP)* Pressure (MAWP)** Actuator (kg)† (kg)† (kg)†
(cu cm)▲ (Bar) (Bar) (kg)
HD 521 2196 14 14 36 5 11 34
HD 721 4277 10.5 14 45 5 11 43
HD 722 7980.5 5 8.5 57 5 11 —
HD 731 5276.6 14 14 74 5 11 45
HD 732 10193 10.5 14 94 5 11 —

Spring-Return Actuators
HD-Series
Maximum Maximum Allowable Approximate With M3 With M3HW With M7
Actuator Displacement Operating Working Weight of Add Add Add
Model Per Stroke Pressure (MOP)* Pressure (MAWP)** Actuator (kg)† (kg)† (kg)†
(cu cm)▲ (Bar) (Bar) (kg)
HD 521-SR40 2196 14 14 48 2 5 29
HD 521-SR60 2196 14 14 49 2 5 29
HD 521-SR80 2196 14 14 50 2 5 29
HD 521-SR100 2196 14 14 55 2 5 29
HD 521-SR125 2196 14 14 56 2 5 29
HD 521-SR150 2196 14 14 57 2 5 29
HD 521-SR200 2196 14 14 62 2 5 29
HD 721-SR40 4277 12.5 14 68 2 5 39
HD 721-SR60 4277 13.5 14 71 2 5 39
HD 721-SR80 4277 14 14 73 2 5 39
HD 721-SR100 4277 14 14 74 2 5 39
HD 721-SR125 4277 14 14 84 2 5 39
HD 721-SR150 4277 14 14 85 2 5 39
HD 721-SR200 4277 14 14 92 2 5 39
HD 722-SR40 7981 6 8.5 98 2 5 —
HD 722-SR60 7981 8 8.5 104 2 5 —
HD 722-SR80 7981 9 10.5 107 2 5 —
HD 722-SR100 7981 10 12 113 2 5 —
HD 732-SR40 10193 11 14 125 2 5 —
HD 732-SR60 10193 12 14 132 2 5 —
HD 732-SR80 10193 13 14 143 2 5 —
HD 732-SR100 10193 14 14 148 2 5 —
HD 732-SR125 10193 14 14 160 2 5 —
HD 732-SR150 10193 14 14 166 2 5 —

NOTES:

† Manual Overrides
M3 Jackscrew
M3HW Jackscrew and handwheel
M11 Piston pump assembly including hydraulic cylinder
M7 Piston pump assembly including hydraulic cylinder

▲ Maximum volume including cavity required for calculating consumption per stroke.

* Maximum Operating Pressure (MOP) is the pressure required to produce the maximum rated torque
of the actuator.
** Maximum Allowable Working Pressure (MAWP) is the maximum static pressure that may be applied to
a fully stroked actuator against the travel stops.

10/98 HPM 2.01


Dimensions – HD-Series (Pneumatic) [mm]

Double-Acting

Model A B C D E F G H J K L M N P Q R S T U
521 843.0 460.2 136.7 151.6 147.6
.500-13
721 851.7 141.2 282.4 81.0 40.4 226.3 73.2 63.5 71.4 63.60 UNC 19.1 142.7 193.5 73.2
469.1 174.8
722 938.3
190.5 206.2
731 1006.3
566.7 173.0 345.9 103.1 51.6 300.0 91.9 85.9 193.5 90.4 82.55 .750-10 25.4 184.2 212.9 95.3
732 1133.3 UNC

Double-Acting with M4 Hydraulic Override

Model A B C D E F G H J K L M N P Q R S T U V
521-M4 920.8 460.2 136.7 150.9
141.2 282.4 81.0 40.4 226.3 73.2 63.5 71.4 63.60 .500-13 19.1 142.7 73.2 503.2
721-M4 938.3 469.1 349.3 UNC 522.2
190.5 215.9
731-M4 1133.3 566.7 173.0 345.9 103.1 51.6 300.0 91.9 85.9 90.4 82.55 .750-10 25.4 184.2 95.3 599.9
UNC

Mounting Dimensions (View A-A) For All HD-Series Actuators


(Dimensions G, H, P, Q, R and S)

Certified dimensional drawing available on request. Contact factory with correct model designation and serial number.

10/98 HPM 3.01


Dimensions – HD-Series (Pneumatic) [mm]

Spring-Return

Spring Size
40 60 80 100 120 150 200
Model Dimension A B C D E F G
521-SR 1125.5 1125.5 1125.5 1272.3 1272.3 1272.3 1353.3 136.7 151.6
382.5
721-SR 1154.2 1154.2 1154.2 1154.2 1273.0 1273.0 — 141.2 282.4 81.0
722-SR 1296.9 1296.9 1398.5 1398.5 — — — 469.1 190.5 206.2
732-SR 1541.5 1541.5 1677.9 1677.9 1782.8 1782.8 — 566.7 173.0 345.9 103.1

Model H J K L M N P Q THD. R S T U
521-SR 147.6
721-SR 40.4 226.3 73.2 63.5 71.4 63.60 .500-13 UNC 19.1 142.7 193.5 73.2
174.8
722-SR
732-SR 51.6 300.0 91.9 85.9 193.5 90.4 82.55 .750-10 UNC 25.4 184.2 212.9 95.3

Spring-Return with M7 Hydraulic Override

Spring Size
40 60 80 100 120 150 200
Model Dimension A B C D E F G
521-SR-M7 1203.5 1203.5 1203.5 1350.3 1350.3 1350.3 1431.0 136.7 151.6
382.5 141.2 282.4 81.0
721-SR-M7 1240.5 1240.5 1240.5 1240.5 1359.7 1359.7 —
190.5 206.2
732-SR-M7 1541.5 1541.5 1677.9 1677.9 1782.8 1782.8 — 566.7 173.0 345.9 103.1

Model H J K L M N P Q THD. R S T U V
521-SR-M7 — 913.6
40.4 226.3 73.2 63.5 71.4 63.60 .500-13 UNC 19.1 142.7 762.0 73.2
721-SR-M7 — 926.3
732-SR-M7 51.6 300.0 91.9 85.9 — 90.4 82.55 .750-10 UNC 25.4 184.2 — 95.3 954.8

Certified dimensional drawing available on request. Contact factory with correct model designation and serial number.

HPM 3.02 10/98