Pipe Data
5
Pipe Data
6
Pipe Data
All products manufactured by Charlotte Testing with or use of compressed air or gas in PVC / ABS
Pipe and Foundry Company are proudly / CPVC pipe or fittings can result in explosive failures and
cause severe injury or death.
made in the U.S.A. • NEVER test with or transport/store
R
compressed air or gas in PVC / ABS / CPVC
pipe or fittings.
• NEVER test PVC / ABS / CPVC pipe or
e
P
fittings with compressed air or gas, or air
over water boosters.
• ONLY use PVC / ABS / CPVC pipe or
fittings for water or approved chemicals.
V
• Refer to warnings in PPFA User Bulletin C
4-80 and ASTM D 1785.
-
D
W
V
P
I
P
E
7
Pipe Data
8
Pipe Data
SDR-35 GASKETED - PS 46
PART NO. NOM. SIZE UPC # QTY. PER LAYING WT. PER AVG. OD MIN. WALL
611942- SKID LENGTH 100 FT. (LBS.) (IN.) (IN.)
9
Pipe Data
Pipe listed in this section meets or exceeds the requirements of ASTMD 2729.
All products manufactured by Charlotte Pipe and Foundry Company are proudly made
in the U.S.A.
10
PVC and ABS DWV Fittings
HUB DIMENSIONS
ABS
SIZE A B C D
11⁄2 1.910 1.895 .687 .156
2 2.385 2.370 .750 .156
3 3.515 3.495 1.500 .218
4 4.515 4.495 1.750 .250
6 6.647 6.614 3.000 .281
PVC
SIZE A B C D P
11⁄4 1.675 1.650 .687 .156 V
C
11⁄2 1.915 1.895 .687 .156 &
2 2.390 2.370 .750 .156 A
3 3.520 3.495 1.500 .218 B
S
4 4.520 4.495 1.750 .250 D
6 6.647 6.614 3.000 .281 W
V
8 8.655 8.610 4.000 .322 F
10 10.776 10.737 5.000 .365 I
T
12 12.778 12.736 6.000 .406 T
I
14 14.035 13.085 7.000 .437 N
16 16.045 15.980 8.000 .500 G
S
11
PVC and ABS DWV Fittings
3 x 6 61⁄2 2
4 x 6 69⁄32 13⁄4
4 x 8 71⁄2 123⁄32
6 x 8 813⁄32 113⁄32
4 x 10** 1125⁄64 415⁄32
4 x 12**
4 x 14(F) 19 93⁄4
4 x 16 (F)
205⁄8 101⁄4
6 x 10 927⁄32 17⁄8
6 x 12** 133⁄8 43⁄8
6 x 14 (F)
6 x 16(F)
8 x 10 103⁄4 11⁄16
8 x 12 123⁄4 21⁄16
8 x 14 (F)
221⁄2 113⁄8
8 x 16 (F)
241⁄4 121⁄8 P
10 x 12 123⁄4 111⁄16 V
10 x 14(F) 173⁄4 53⁄4 C
&
10 x 16(F) 25 12 A
12 x 14(F) 1611⁄16 33⁄16 B
12 x 16(F) 203⁄4 67⁄16 S
D
14 x 16(F) 197⁄8 47⁄16 W
V
F
I
T
T
I
N
Fabricated
(F)
G
** Assembled from two molded components S
Note: Shading indicates available in PVC only.
13
PVC and ABS DWV Fittings
3 7⁄32 3⁄4
4 1⁄4 7⁄8
6 5⁄16 17⁄16
8(F) 15
⁄16 21⁄4
10 (F) 15
⁄16 21⁄4
12 (F)
1 1
⁄8 27⁄16
P
V
C
&
A
B
S
D
W
V
F
I
T
T
I
N
G
** Assembled from two molded components S
Note: Shading indicates available in PVC only.
17
PVC and ABS DWV Fittings
10 x 8 11⁄2
12 x 8 113⁄16
Fabricated
(F)
of PVC 444X.
Note: Shading indicates available in PVC only.
18
PVC and ABS DWV Fittings
Fabricated
(F)
3 113⁄16
4 127⁄32
4 x 3 25⁄32
(P)
Plain End: Joint can be made with compression
gasket only.
(F)
Fabricated
Note: Shading indicates available in PVC only.
22
PVC and ABS DWV Fittings
2 11⁄2 23⁄8
3 13⁄4 31⁄4
4 23⁄16 315⁄16
6 21⁄16 515⁄64
8 2 63⁄32
10 31⁄8 85⁄32
12 331⁄64 91⁄2
14(F) 93⁄8 159⁄16
16(F) 105⁄16 181⁄2
3 13⁄16 25⁄16
4 1 23⁄4
6 11⁄2 53⁄64
8(F) 61⁄8 1015⁄16
10(F) 511⁄16 113⁄4
12(F) 51⁄2 141⁄16
14(F) 69⁄16 137⁄8
16(F) 85⁄16 163⁄4
Fabricated
(F)
P
V
C
PART NO. 330X* &
A
Closet Bend, Reducing B
with Test Cap S
HUB X SPIGOT D
SIZE A B W
V
3 x 4* 6 35⁄8 F
I
T
T
I
N
Fabricated
(F)
G
* Available in ABS only S
Note: Shading indicates available in PVC only.
31
PVC and ABS DWV Fittings
14 x 14 x 6 111⁄4 12 6
(N)(F)
16 x 16 x 6(N)(F) 121⁄4 14 7
16 x 16 x 8(N)(F) 125⁄8 16 8
16 x 16 x 10(N)(F) 13 18 9
16 x 16 x 12(N)(F) 137⁄16 193⁄4 97⁄8
16 x 16 x 14 1315⁄16 23 111⁄2
(N)(F)
Fabricated
(F)
P
PART NO. 431 V
C
Double Sanitary Tee &
Street, Reducing A
(Sanitary Cross) B
SPIGOT X HUB X HUB X HUB S
SIZE A B C D
3 x 3 x 11⁄2 x 11⁄2 29⁄16 43⁄16 31⁄4 W
V
F
I
T
T
I
N
G
S
Note: Shading indicates available in PVC only.
37
PVC and ABS DWV Fittings
P
V
C
&
A
B
S
D
W
V
F
I
T
T
Fabricated
(F) I
** Assembled from two molded components
N
G
*** Assembled from three molded components S
Note: Shading indicates available in PVC only.
39
PVC and ABS DWV Fittings
Cleanout Tee
HUB X HUB X FPT
SIZE A B C
11⁄2 115⁄16 23⁄8 13⁄16
2 21⁄4 3 11⁄2
3 211⁄16 37⁄8 115⁄16
4 33⁄8 51⁄8 29⁄16
6 4 8 4
8 51⁄4 101⁄2 55⁄32
8 x 8 x 4(F) 73⁄4 91⁄4 45⁄8
8 x 8 x 6(F) 81⁄4 111⁄4 55⁄8
10(F) 123⁄4 121⁄2 61⁄4
10 x 10 x 4(F) 811⁄16 113⁄4 57⁄8
10 x 10 x 6(F) 105⁄8 113⁄4 57⁄8
10 x 10 x 8 103⁄8 103⁄8 53⁄16
12(F) 133⁄8 141⁄2 71⁄4
12 x 12 x 4(F) 911⁄16 10 5
12 x 12 x 6(F) 95⁄16 121⁄8 61⁄16
12 x 12 x 8 115⁄32 101⁄4 61⁄32
12 x 12 x 10(F) 135⁄16 121⁄2 61⁄4
Fabricated
(F)
Fabricated
(F)
10 x 10 x 6 x 6(F) 1415⁄16 3
⁄4 145⁄8
10 x 10 x 8 x 8 18 3 ⁄16 151⁄16
(F) 7
12 x 12 x 4 x 4(F) 1113⁄16 1 14
12 x 12 x 6 x 6(F) 1511⁄16 7⁄16 171⁄8
12 x 12 x 8 x 8(F) 187⁄8 33⁄16 161⁄2
12 x 12 x 10 x 10(F) 2111⁄16 37⁄8 181⁄16
14 x 14 x 4 x 4(F)
14 x 14 x 6 x 6(F) 15 1 163⁄16
14 x 14 x 8 x 8(F) 19 27⁄16 1719⁄32
14 x 14 x 10 x 10(F) 217⁄8 4 183⁄4
14 x 14 x 12 x 12 25 ⁄16 5 19 ⁄8
(F) 3 7
16 x 16 x 4 x 4
(F)
Fabricated
(F)
P
V
C
&
PART NO. 700 A
B
S
Return Bend
HUB X HUB D
SIZE A B C
W
V
11⁄2 31⁄2 13⁄4 13⁄4 F
2 57⁄32 23⁄8 23⁄8 I
T
3 63⁄4 31⁄16 31⁄16 T
4 81⁄2 311⁄16 311⁄16 I
N
G
S
Note: Shading indicates available in PVC only.
49
PVC and ABS DWV Fittings
Pipe listed in this section meets or exceeds the requirements of ASTM D 2949. T
H
I
N
All products manufactured by Charlotte
Pipe and Foundry Company are proudly Testing with or use of compressed air or gas in PVC / ABS W
/ CPVC pipe or fittings can result in explosive failures and A
made in the U.S.A. cause severe injury or death.
• NEVER test with or transport/store L
compressed air or gas in PVC / ABS / CPVC
pipe or fittings.
L
• NEVER test PVC / ABS / CPVC pipe or
fittings with compressed air or gas, or air
over water boosters.
P
• ONLY use PVC / ABS / CPVC pipe or V
fittings for water or approved chemicals.
• Refer to warnings in PPFA User Bulletin C
4-80 and ASTM D 1785.
D
W
V
55
PVC Thin Wall Schedule 30 Fittings
HUB DIMENSIONS
56
PVC Thin Wall Schedule 30 Fittings
D
PART NO. PVC 1105X W
V
Fitting Cleanout Adapter
with Cleanout Plug
SPIGOT
SIZE A B
3 7
⁄32 117⁄32
57
PVC Thin Wall Schedule 30 Fittings
58
PVC Thin Wall Schedule 30 Fittings
D
PART NO. PVC 1400 W
V
Sanitary Tee
HUB X HUB
SIZE A B C
3 231⁄32 41⁄2 117⁄32
59
PVC Thin Wall Schedule 30 Fittings
60
PVC Thin Wall Schedule 30 Fittings
D
W
V
61
Certification
63
LIMITED WARRANTY
Charlotte Pipe and Foundry Company® (Charlotte Pipe®) Products are warranted to be free from
manufacturing defects and to conform to currently applicable ASTM standards for a period of
five (5) years from date of delivery. Buyer’s remedy for breach of this warranty is limited to
replacement of, or credit for, the defective product. This warranty excludes any expense for removal
or reinstallation of any defective product and any other incidental, consequential, or punitive
damages. This limited warranty is the only warranty made by seller and is expressly in lieu
of all other warranties, express and implied, including any warranties of merchantability
and fitness for a particular purpose. No statement, conduct or description by Charlotte Pipe
or its representative, in addition to or beyond this Limited Warranty, shall constitute a warranty.
This Limited Warranty may only be modified in writing signed by an officer of Charlotte Pipe.
This Limited Warranty will not apply if:
1) The Products are used for purposes other than their intended purpose as defined by local
plumbing and building codes, and the applicable ASTM standard.
2) The Products are not installed in good and workmanlike manner consistent with normal
industry standards; installed in compliance with the latest instructions published by Charlotte
Pipe and good plumbing practices; and installed in conformance with all applicable plumbing,
fire and building code requirements.
3) This limited warranty does not apply when the products of Charlotte Pipe are used with the
products of other manufacturers that do not meet the applicable ASTM or CISPI standards
or that are not marked in a manner to indicate the entity that manufactured them.
4) The Products fail due to defects or deficiencies in design, engineering, or installation of the
piping system of which they are a part.
5) The Products have been the subject of modification; misuse; misapplication; improper
maintenance or repair; damage caused by the fault or negligence of anyone other than
Charlotte Pipe; or any other act or event beyond the control of Charlotte Pipe.
6) The Products fail due to the freezing of water in the Products.
7) The Products fail due to contact with chemical agents, fire stopping materials, thread sealant,
plasticized vinyl products, or other aggressive chemical agents that are not compatible.
8) Pipe outlets, sound attenuation systems or other devices are permanently attached to the
surface of Charlotte® PVC, ABS or CPVC products with solvent cement or adhesive glue.
Charlotte Pipe products are manufactured to the applicable ASTM or CISPI standard. Charlotte
Pipe and Foundry cannot accept responsibility for the performance, dimensional accuracy, or
compatibility of pipe, fittings, gaskets, or couplings not manufactured or sold by Charlotte Pipe
and Foundry.
Any Charlotte Pipe products alleged to be defective must be made available to Charlotte Pipe at
the following address for verification, inspection and determination of cause:
Charlotte Pipe and Foundry Company
Attention: Technical Services
2109 Randolph Road
Charlotte, North Carolina 28207
Purchaser must obtain a return materials
authorization and instructions for return
shipment to Charlotte Pipe of any product
Testing with or use of compressed air or gas in PVC / ABS claimed defective or shipped in error.
/ CPVC / Cast Iron pipe or fittings can result in explosive
failures and cause severe injury or death. Any Charlotte Pipe product proved to be
• NEVER test with or transport/store defective in manufacture will be replaced
compressed air or gas in PVC / ABS /
CPVC / Cast Iron pipe or fittings. F.O.B. point of original delivery, or credit
• NEVER test PVC / ABS / CPVC / Cast Iron will be issued, at the discretion of Charlotte
pipe or fittings with compressed air or
gas, or air over water boosters. Pipe.
• ONLY use PVC / ABS / CPVC / Cast Iron
pipe or fittings for water or approved
4/15/10
chemicals.
• Refer to warnings in PPFA User Bulletin
4-80 and ASTM D 1785.
Charlotte and Charlotte Pipe are registered trademarks of Charlotte Pipe and Foundry Company.
64
Notes
65
Notes
66
Notes
67
PO BOX 35430
CHARLOTTE
NORTH CAROLINA 28235
PHONE (704) 348-6450
(800) 572-4199
FAX (800) 553-1605
LITERATURE BY FAX (800) 745-9382