Protective Device Analysis

Verify and enhance your power system’s


protection with CYME’s Protective Device
Analysis.
The Protective Device The right selection of protective • Inspection of the proper • Customizable display options
devices and their proper coordination for motor for curve colors, tags and
Analysis module is an sizing are important issues for starting, transformer inrush other grid options
indispensable tool to engineers desiring to reduce and cable damage • Export function to easily
the impact caused by any short-
help power engineers circuit on the network and to
• Tools to calculate precisely include time-current plots in
effectively address the time and current margins reports
minimize equipment failures.
between curves
protection issues by CYME’s Protective Device Not only does CYME provide
Analysis module provides • Modification of any setting the useful tools listed above to
analyzing time-current engineers with a wide range to visualize the change make any study simple, it also
curves. of tools to efficiently and interactively on-screen offers advanced analyses to
accurately design and validate assist engineers in examining
With an extensive library the coordination scheme of their the coordination and protection
power system. range of the devices on the
of over 15000 protective network more closely.
Time over current plots are
devices, an intuitive generated within the user-
graphical plot and a friendly interface of CYME,
broad range of tools and which offers:

analyses, planning and • Log-log plot to display time-


current curves of protective
validating protection devices such as fuses, relays,
schemes has never been circuit breakers and reclosers
easier with the CYME • Library containing more than
100 000 curves from North
Power System Analysis American, European and Asian
Software. manufacturers
• Online update of the library of
curves
Protective Network Protection Analysis
The Network Protection analysis
Minimum Fault Analysis
The Minimum Fault analysis
Sequence of Operation
The Sequence of Operation
can be used to verify the is offered to assist engineers analysis evaluates the impact of
Device Analysis coordination, the protective
reach and the loading of all
in the verification of whether
the protective devices can
a fault on the network to provide
the sequence of protective
protective devices in a network. adequately detect and clear the device operations triggered.
minimum faults seen in their
Main capabilities include: Main capabilities include:
Verify and enhance your respective protection zone.
• Verify the coordination • User-defined fault location
power system’s protection between successive pairs of
A detailed report is provided
to list all areas that are Simulation of any fault type
with CYME’s Protective devices according to user-
inadequately protected. Those

Device Analysis. defined criteria • Calculation of the fault current


areas are also color-coded on
the one-line diagram for easier and opening time of each
• Examine whether a device
visualization. protective device while taking
operates for all faults in its
into account the state of the
protection zone within a user-
network at each operation
defined maximum permitted
operating time • Take into account device
settings, including delays and
• Compare the current through
reset times
each device to a user-
defined maximum permitted • Tracing of the protective
continuous load current devices triggered in the one-
line diagram
• Verify if cables are protected
by a device on all its length • Tabular report listing the
sequence of devices triggered,
• Fuse clearing or fuse saving
the opening time and fault
option
current detected at each
• Study both primary and operation
secondary protective devices
• Specialized report and
indication on one-line
diagram to highlight curve
intersections, reach and
loading problems

Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com

CYME International T&D


1485 Roberval, Suite 104
St.Bruno, QC, Canada J3V 3P8
P: 450.461.3655
F: 450.461.0966 Eaton, Cooper Power Systems and CYME are
P: 800.361.3627 (Canada/USA) valuable trademarks of Eaton in the U.S. and
CymeInfo@eaton.com www.cyme.com other countries. You are not permitted to use
these trademarks without the prior written
© 2014 Eaton consent of Eaton.
All Rights Reserved
Printed in Canada All other trademarks are property
Publ. No. BR 917 016 EN · December 2014 of their respective owners.