Você está na página 1de 5

PROJECT: TC_D- Potain MR415 at

Meriton Apartments- 52 Walker St Rhodes


TENSION ANCHOR DESIGN
VERSION 1.3
JOB No. 10837N 22-Jun-18
INPUT DATA
Working (Serviceability) load = 3750 kN. Load Factor = 1.5
Ultimate tension load N* t = 5625 KN. (The required load necessary to ensure that the structure behaves in a satisfactory manner)
Proof load Tt ( kN) = 4875 2 ( BS 8081-1989 Clause B5.1 proof load = 1.25 * working load for temp anchors, RBP uses 1.3, and 1.5 *
(Stressing load) Permanent Anchors working load for permanent anchors)
Lock off load (kN) = 4125 Temporary Anchors
(BS 8081-1989 recommends 1.1* Working load)
Long term load in anchorage(kN) = 3750 (Designer to enter value) usually equal to working load
No. of anchors in group = 4
No of Rows of anchors = 2 Horiz. Spacing of anchors = 550 mm
No of Columns of anchors = 2 Vert. Spacing of anchors = 550 mm

Type of Anchor used = 1

Draw in at lock off = 1 mm


Minimum extension required = 2 mm

Density of rock = 18 Kn/m^3 Ref: Geotech Report 45298 dated 1-Mar-08


Angle of rock cone = 45 Degrees from vertical. By : Douglas Partners
Grout strength = 40 MPA.
Shear strength of rock = 0 KPA. (Assume zero KPA. if rock is fractured)
Depth of soil over rock = 0 mm.
Density of soil = 18 Kn/m^3

CHECKING OF ANCHOR TENSILE STRENGTH

Req'd. CT Stress Bar Dia. = NOT APPLICABLE AS PERMANENT ANCHOR Adopt NOT APPLICABLE.

Req'd. CT Stress Bar Dia. = 56.0 AS TEMPORARY ANCHOR Adopt 56


N*/anchor = 1406 KN.
UTS/anchor = 2537 KN.
Max. Allow anchor load = 1268 KN. (.5* UTS OF CT STRESS BARS, .5*UTS OF STRANDS) (General rule used by VSL that the
Working load = 937.5 Kn/anchor of the ultimate strength of the anchor)
Proof (Stressing) load = 1219 KN. /anchor
Lock off load = 1031 KN. /anchor

CALCULATION OF BOND LENGTH

ANCHORAGE BOND LENGTH OF STEEL TO GROUT

Based on BS 8110 Part 1 1985 Clause 3.12.8.4

Design ultimate anchorage bond stress = beta* (f'c cube)^.5 MPA beta = .40 fc cube =1.25*f'c
= 2.8 MPA.

Anchorage bond length required (mm) = 2826

SHEAR STRESS IN GROUT COLUMN

Based on AS 1481-1978 Clause 5.10.4

Design ultimate average shear stress = 1.5 * 2.8 MPA = 4.2 MPA.

Bond length required (mm) = NOT APPLICABLE AS PERMANENT ANCHOR


Bond length required (mm) = 1178 AS TEMPORARY ANCHOR

BOND AT GROUT / GROUND INTERFACE

Based on AS 1481-1978 Clause 5.10.5

Design ultimate shear stress = 0.45 MPA. (=1.5* Working bond stress)
Min.drill hole dia.(mm) = 0 125 Adopted drill hole dia.= 150 O.K.
Bond length required (mm) = NOT APPLICABLE AS PERMANENT ANCHOR
Bond length required (mm) = 6631 AS TEMPORARY ANCHOR
or (min) = 3000 Rock type Strength grade Mpa Working bond stress
Basalts, Tuffs 20-80 .57-.85 Mpa.
ROCK CONE PULL-OUT RESISTANCE Sandstones, mudstones 20-80 .57-.85
Granite 20-80 1.38-1.55
SINGLE ANCHOR Fine grained s'stone 20-80 0.3
Slates, slaty shale 20-80 0.6
Based on: 0.8 * Wt. Rock cone = 1.5 * Tension load in the group of anchors. Grey shale 0.32
Phyllite 13-50 0.6
Required rock cone length = 4534 mm. overlying soil not taken into account
Required rock cone length = 5000 mm. overlying soil taken into account y/m dVy/Vc
Lab... O.K. 0 1
0.2 0.8
0.4 0.65
MULTIPLE ANCHORS 0.6 0.48
0.8 0.35
Based on: 0.8 * Wt. Rock cone = 1.5 * Tension load in the group of anchors. 1 0.23
1.2 0.18
1.4 0.1
1.6 0.05
1.75 0
Required rock cone length = #N/A mm. overlying soil not taken into account
Required rock cone length = 6000 mm. overlying soil taken into account
O.K. y/m x/n L Vc
#DIV/0! #DIV/0! 0 0
1.1 1.1 500 1.884956
ANCHOR LENGTH 0.55 0.55 1000 15.07964
0.366667 0.3666666667 1500 50.8938
FREE LENGTH 0.275 0.275 2000 120.6372
0.22 0.22 2500 235.6194
0.183333 0.1833333333 3000 407.1504
AT ANCHOR STRESSING LOAD, EXTENSION >= MIN REQUIRED EXTENSION 0.157143 0.1571428571 3500 646.5398
AND/OR >= DRAW IN+REQUIRED EXTENSION AT LOCK OFF NA 0.1375 0.1375 4000 965.0973
OK 0.122222 0.1222222222 4500 1374.133
FREE LENGTH REQUIRED = 3000 = 3000 0.11 0.11 5000 1884.956
0.1 0.1 5500 2508.876
EXTENSION AT PROOF LOAD (mm) =
NOT APPLICABLE AS PERMANENT ANCHOR 0.091667 0.0916666667 6000 3257.203
8 AS TEMPORARY ANCHOR 0.084615 0.0846153846 6500 4141.247
EXTENSION AT LOCK OFF LOAD (mm) = NOT APPLICABLE AS PERMANENT ANCHOR 0.078571 0.0785714286 7000 5172.318
7 AS TEMPORARY ANCHOR 0.073333 0.0733333333 7500 6361.725
LOCK OFF EXTENSION + DRAW IN EXTENSION = 8 (SHOULD BE LESS THEN 0.06875 0.06875 8000 7720.778
EXT. AT PROOF LOAD) 0.064706 0.0647058824 8500 9260.787
0.061111 0.0611111111 9000 10993.06
MIN. REQ'D. EXTENSION = 2 (DEPENDS ON EQUIP. USED) 0.057895 0.0578947368 9500 12928.91
0.055 0.055 10000 15079.64
0.052381 0.0523809524 10500 17456.57
NOT APPLICABLE AS PERMANENT ANCHOR 0.05 0.05 11000 20071.01
FREE LENGTH OK AS TEMPORARY ANCHOR 0.047826 0.047826087 11500 22934.25
0.045833 0.0458333333 12000 26057.63
0.044 0.044 12500 29452.43
0.042308 0.0423076923 13000 33129.98
0.040741 0.0407407407 13500 37101.58
0.039286 0.0392857143 14000 41378.55
0.037931 0.0379310345 14500 45972.18
0.036667 0.0366666667 15000 50893.8

TYPE OF ANCHOR USED = CT Stress Bar with no dead end plate NOT APPLICABLE. AS PERMANENT ANCHOR no dead end plate
CT Stress Bar with no dead end plate 56 Dia. no dead end plate
REQUIRED BOND LENGTH (MM) = 6631
REQUIRED FREE LENGTH (MM) = 3000
REQUIRED ROCK CONE LENGTH = #N/A
TENSION ANCHOR DESIGN JOB NO. 10837N 22-Jun-18
VERSION 1.2
PROJECT: TC_D- Potain MR415 at
CT Stress Bar with no dead end Meriton Apartments- 52 Walker St Rhodes
plateDia.
56 0

GROUND LEVEL
CONC. FOOTING
CONC. FTG.

3000
0
SOIL

18 kn/m^3
ROCK LEVEL

FREE
LENGTH
ROCK CONE LENGTH

9631
ROCK 18 kn/m^3

6000
STRATUM

ANCHOR LENGTH
BOND LENGTH
EQ.
45 45

6631
EQ.
no dead end
plate

150

DETAIL OF TEMPORARY ANCHOR ANCHOR LOADS AND EXTENSIONS EXTENSION


(mm)
(N.T.S) WORKING LOAD (KN) IN EACH ANCHOR 937.5
LOAD FACTOR 1.5
TOTAL No. OF ANCHORS ULTIMATE LOAD (KN) IN EACH ANCHOR 1406
IN THE ANCHOR GROUP = 4 ULTIMATE STRENGTH (KN) OF EACH ANCHOR 2537
PROOF (STRESSING) LOAD (KN) IN EACH ANCHOR 1219 8
No. of rows of anchors = 2 at 550 mm. LOCK OFF LOAD (KN) IN EACH ANCHOR 1031 7
LONG TERM LOAD (KN) IN EACH ANCHOR 937.5
No. of columns of anchors = 2 at 550 mm.
MIN ALLOWABLE EXTENSION (mm) 2
MAX. ALLOWABLE DRAW IN AT LOCK OFF (mm) 1
Ref: Geotech Report : 45298 dated 1-Mar-08
INPUT DATA By : Douglas Partners

ANCHOR GROUP WORKING LOAD = 3750 KN.


LONG TERM LOAD IN ANCHOR GROUP = 3750 KN.
Grout strength (MPA) = 40

CHECKING OF ANCHOR TENSILE STRENGTH. BOND AT GROUT / GROUND INTERFACE

Req'd. CT Stress Bar Dia. = NOT APPLICABLE AS PERMANENT ANCHOR Design ultimate shear stress = 0.45 MPA.
Req'd. CT Stress Bar Dia. = 56 AS TEMPORARY ANCHOR
Bond length required (mm) = NOT APPLICABLE AS PERMANENT ANCHOR
Bond length required (mm) = 6631 AS TEMPORARY ANCHOR
or (min) = 3000
CALCULATION OF BOND LENGTH

ANCHORAGE BOND LENGTH OF STEEL TO GROUT

Anchorage bond length required (mm) = 2826

SHEAR STRESS IN GROUT COLUMN


ROCK CONE PULL-OUT RESISTANCE
Design ultimate average shear stress = 4.2 MPA.
Bond length required (mm) = NOT APPLICABLE AS PERMANENT ANCHOR SINGLE ANCHOR
Bond length required (mm) = 1178 AS TEMPORARY ANCHOR
Required rock cone length = 4534 mm. overlying soil not taken into account
Required rock cone length = 5000 mm. overlying soil taken into account

MULTIPLE ANCHORS

Required rock cone length = #N/A mm. overlying soil not taken into account
Required rock cone length = 6000 mm. overlying soil taken into account

Total Anchor Length Required = #N/A mm.

FREE LENGTH = 3000 mm.

PROJECT: TC_D- Potain MR415 at


Meriton Apartments- 52 Walker St Rhodes
0

JOB NO. 10837N 22-Jun-18


35