Rs S$ & R CONSCLTANTS
“STRUCTURAL DESIGN » GEOTECHNICAL . SOFTWARE » SHOP DRAWING . PROJECT MANAGEMENT
S&RVENR/14/394
‘Thursday, October 23, 2014
ie Elamkulam
Site : Padanna
Project: Proposed Project Of Mount Shenoy Medical Centre
Soil Investigation: M/s JVM. Associates
Bore-hole Details: 1 ,2 (9/10/14,1 130/14)
‘Recommendation
L. Ata depth of 2 m and a size of 2mx2m footing, safe bearing capacity of 16
“Timnd cam be used in lateritic gravelly silty sand with N value > 28. Ensure that
same strata is available throughout the site.
2, Foundation to be constructed as per latest IS codes and to be certified by @
qualified site engineer. Authenticity of the lab report with respect to the site
also to be verified by the elient, before construction.
3, Above recommendations are based on the soil investigation report based on
the actual bore hole data, Any difference in soil profile to be referred to the
consultant to modify the recommendation or to the designer to change the
design