feature pumping with low NPSH

Dear ‘Pump Guy’…


Larry Bachus (aka The Pump Guy) discusses the effects on pump performance of fluid
velocity, shearing and suction piping, and the underlying issue of adequate net positive
suction head.

I
always like it when someone ‘Hello J.P., hear words like pseudo-plastic,
speaks up in class or when I dilatant, rheopectic and thixotropic. If
receive a question by e-mail. The To answer your question, I went to my I used those words, people would stop
person who asks a question is copy of the same manual and read it writing to the Pump Guy. They
representing the others, who might be for myself. Yep!! That’s what it says all depend on me for real-world words
afraid to ask. The request for more right. Let’s home in on the words… and practical explanations. Anyway,
information or a clarification is also a “unusually good”. What does that the shear sensitivity must be
message to me that I can improve my mean? considered. It’s not an issue with most
communication to the class. And the common liquids, but if you’re pumping
best way to know a million answers is When the teacher tells the students to blood, emulsions, or peanut butter,
to investigate and research a million “be good”, each student perceives “be then learn more about shear
and one questions. good” with a different meaning. One sensitivity.
child thinks it means to stop looking
So then I find myself drifting back and out the window, another thinks it Soapy water in the bathtub tends to
forth from my desktop to the kitchen means don’t cheat on the quiz, or that foam, froth and form bubbles when the
at 1:30 a.m., raiding the fridge and he should tidy his desk, or sit up rug rats (kids and grandkids) are
munching, while I ponder the straight, or pay attention… Maybe the splashing (shearing is the correct word).
questions put to the ‘Pump Guy’. teacher meant “Be quiet!” Then, why Thirty years ago, fresh out of university, I
didn’t she say what she meant? moved into an apartment with an
Dear Pump Guy, automatic dishwasher. I didn’t have any
Next, what does “unusually good” automatic dishwasher detergent so I
I am a mechanical engineer here in mean? Is this different from “usually used laundry soap in my dishwasher. The
Charlotte, NC. We engineer, procure good”? How is this different from just kitchen filled with suds! At the ocean,
and build new fossil-fueled power plain “good”? the seawater with salt tends to foam
stations. I recently read your magazine and froth as the waves break (shear)
article on back pullout pumps. Back to the teacher; maybe what she against the beach. So pumping
meant was, “stop throwing spitballs, detergents and hydroxides (NaOH,
I am wondering if you can shed some light don’t look out the window, stop CaOH), and electrolytes including
on a topic that we have been debating doodling, don’t cheat, straighten your salts (NaCl, NH4Cl, CaCl e.g. boiler
(arguing about) in the office. According desk and papers, sit up straight, pay and water treatment chemicals), is
to our supplier’s pump manual (p. 607), attention, and shut up”! Well then, likely to form bubbles with shear in
“Suction pipe velocities should be in the 5 she should have said what she meant. the suction pipe.
to 8 feet per second range unless suction Maybe your pump company meant “all
conditions are unusually good. Higher that stuff”, too. So let’s cover “all that Consider moving (shearing) liquids
velocities will increase friction loss and stuff”…’ with entrained gas, and liquids with a
can result in troublesome air or vapor low vapour pressure. Certainly everyone
separation”. has opened a can of soda after it has been
The effects of shear dropped, and had it spew. It’s one thing
Assuming the NPSH criteria is met, what to shake and explode a bottle of
is wrong with higher velocities? Does We’ll start with the liquid. Some champagne if you have just won the
dissolved air in water separate and form liquids are more sensitive to shear. NASCAR 500 at Talladega, but you
air bubbles at high line velocities? This means their properties will wouldn’t do that in your kitchen, would
change with agitation or turbulence. you? You can shake a canister of propane
Any comment would be welcome. Dissolved gases and other components or refrigerant and hear the liquid
may separate from the liquid and come sloshing inside the container. Yet, when
Regards, out of suspension. Shear is plotted on a you open the valve and the liquid shears
stress–strain graph. Temperature is a through the exit nozzle, there is only gas.
J. P., P.E. factor and the liquid’s viscosity is a Nothing drips onto the floor. So these
Mechanical & Layout Engineering factor. Viscosity is quantified as shear gassing liquids are susceptible to change
Supervisor stress / rate of shear. I hate it when I phase with shear and velocity.

WORLD PUMPS March 2004 0262 1762/04 © 2004 Elsevier Ltd. All rights reserved 29
feature pumping with low NPSH

Suction piping arrangement is crucial


I was working as a pump consultant in a steam plant a while ago emergency teardowns over the years, the coupling guard had been lost
and the maintenance engineer directed me to this sick pump or mislaid. As I observed the pump, I saw that it was a horizontal
(Figure 1). The pump drains a tank of cold water and supplies the axially split case pump. This pump does not use axial control bearings
plant with industrial water pressure. The engineer said that because the shaft is considered to be axially stable. You can see the
although this is not a critical pumping application, it was just radial control bearings on both ends of the shaft (Figure 3). Because of

Figure 4. The curled hose and 90º elbow are destroying the pump’s axial
Figure 1. The sick pump. stability.

Figure 5. Doctored image showing recommended piping arrangement.


Figure 2. The coupling guard is missing.
its design, half of the suction flow enters into each of the two eyes of
the double suction impeller, and tends to axially stabilize the shaft.
So, the bearings must only limit radial motion and imbalance in the
shaft.

The suction piping leading to this type of pump must be straight. This
length of curled hose and the horizontal 90º elbow at the pump’s
suction nozzle is destroying the axial stability (Figure 4). The velocity
and volume of flow through the elbow’s OD is about five times greater
Figure 3. Radial control bearings. than through the ID of the elbow. This overloads the left eye of the
impeller and the entire shaft assembly is shifting to the right away
about the most problematic pump in the whole plant. The pump from the motor.
leaks all the time (there’s a constant pool of leakage, growing algae
and ferns on the pump foundation) and the coupling, bearings and Those radial bearings are not designed to limit or control axial thrust.
seals had been failing three or four times per year for the past 12 The faces are opening on the left mechanical seal, and the faces are
years. The engineer said they injected the bearings with synthetic crushing and grinding on the right mechanical seal. And the coupling
grease in an effort to extend the life of the bearings, but the faces are separating.
synthetic grease was not performing well.
I did not recommend any brand of mechanical seal or synthetic
The engineer said they had installed numerous Chesterton, John grease. I recommended that he scrap that curved hose and elbow
Crane and Dura mechanical seals over the years in an effort to stop assembly and install a straight length of pipe leading to the pump’s
the leakage, but none of the seals would give good service on this suction (Figure 5). A pump’s design is not really complicated. It’s just
cold-water pump. He said the seal salesmen avoided this pump and a rotating shaft inside a cast housing. It certainly doesn’t have as many
had stopped visiting the plant. He said they had gone back to packing parts and components in relative motion as the engine of your car, or
the pump with rope packing. The engineer asked me to recommend a a cuckoo clock (two devices that will run for years without problems).
good mechanical seal. Most pump problems actually occur outside the pump.

I immediately noticed that there was no coupling guard between the Give your seals and bearings their best opportunity to survive. Pay
motor and pump (Figure 2). The engineer said that with so many attention to the suction piping arrangement.

30 www.worldpumps.com WORLD PUMPS March 2004


feature pumping with low NPSH

Standard cold water has dissolved The diameter (ID) of suction piping NPSHA is the energy in the fluid
oxygen in it. That’s what the fish should be as large as possible. The available to the pump. The fluid and
breathe. This dissolved oxygen forms shear is inversely proportional to the the pumping system determine this
on the bottom of a saucepan (as tiny diameter. This means that as the energy. Certain factors add to or
bubbles) when heated on the stove diameter increases, the shear increase the available energy. Other
before the actual boiling begins. This decreases. (Put this into your cheat factors subtract from or decrease that
is also the reason that DA (deaerator) sheets.) If the pump has a 6-inch energy. The addition and subtraction
tanks were invented for boiler-feed suction nozzle, the worst thing you can of these factors is the total energy,
water pumps. Turbulence and velocity do is bring 6-inch or smaller diameter called NPSHA. The NPSHA must be
(shear) can cause separation. pipe to the pump. It is infinitely better greater than the NPSHR with as much
to bring 8-inch or even 10-inch pipe safety margin as possible.
to the pump and then pass through a
Suction piping 10-to-6-inch eccentric reducer at the The NPSHR is the energy in the fluid
pump suction nozzle. required by the pump. It’s the pump’s
As for suction piping, the Pump Guy minimum requirement at the impeller’s
says this should be as short as possible Regarding fluid velocity in a pipe, 5–8 eye. Think of it this way (and put it into
(see box). The pump should be as ft/s is about the industry standard. The your cheat sheets). You breathe because
close to the suction source as possible Pump Guy says slower is better: 4 ft/s is your body requires oxygen. You get this
with minimum piping. Short pipe better than 5, and 3 ft/s is better than 4. required oxygen from the atmospheric
means short shear. Long pipe means The limiting factor is cost. There will air. The available oxygen in the air must
sustained shear even if the shear is low. probably come a point where the always be greater than the oxygen that
If the pump is draining a tank, mount purchasing agent won’t let you buy 10- your body requires. If your body should
the pump on the same tank pad if inch diameter pipe for 1 gpm of flow. require more oxygen than the oxygen
possible. Consider a submersible However, slower is always better unless available to your body, then you would
pump. You can’t get any closer than there is an engineering, practical or be starved of oxygen. The degree of
putting the pump inside the tank. safety reason for high velocity. starvation will determine how long
before you die. Likewise, the NPSHA
The suction piping should also be as When pumping solids and slurry, then available in the system must always be
straight as possible. (Put this in your there may be a good reason for higher greater than the NPSHR required by the
cheat sheets.) Avoid elbows and turns. fluid velocity. If the velocity were too pump. The NPSHR is charted at
Eliminate elbows, if possible; if turns slow, then the solids might settle and different flows on the pump’s
are necessary they should be long, form a dam in the pipe. In this case, performance curve.
sweeping turns and they should be as maybe a certain higher velocity must
far away from the suction nozzle as be respected.
possible. There should be a straight Changing definitions
run of pipe leading to the pump Sometimes firemen need high
suction nozzle. The straight run may velocity. A burning building puts out a As I write this, the definitions for
slope slightly upwards towards the lot of heat and may collapse or NPSHA and NPSHR are changing.
pump if the suction source is below the explode. The firemen are forced to The current NPSHR (as decided by
pump centre-line. fight the fire from a distance. When the Hydraulics Institute (HI) and the
they need to squirt the water from 100 pump manufacturers) of a pump is a
The suction piping should have only feet away, or drag a heavy fire hose up a value representing a 3% loss in pump
minimum valves, flanges and intrusive ladder, then high fluid velocity comes performance due to decreased suction
instrumentation (probes, paddle- in handy. head (energy). And if NPSHA should
wheels, etc.) as required. All suction be greater than NPSHR, then the
valves and intrusive instrumentation current NPSHA value for a system
should be as far upstream from the NPSH criteria could be anything from 0% loss of
pump suction as possible. (This goes function up to 2.999% loss in pump
into your cheat sheets.) This reduces Up to this point we’ve covered the function before declaring inadequate
turbulence (shear) to the pump. liquid and the suction piping leading to NPSHA. Under the current
Minimally, with oversized diameter the pump. Everything I’ve said so far, definition, the pump would be in
suction piping, there might be an except for firemen and shear sensitive obvious cavitation even when the
eccentric pipe reducer (coming up liquids, brings me to the next point, system’s NPSHA is minimally above
from the bottom) at the pump suction which is the pump. There is nothing the NPSHR.
nozzle, and a suction pressure gauge wrong with higher suction pipe
(not considered intrusive) screwed velocities provided that the NPSH (net Some people say this is crazy, and it is.
into a boss on the housing at the positive suction head) criteria NPSHA I mean, do you really have to faint
lateral centre-line. and NPSHR are met. before someone declares that the

WORLD PUMPS March 2004 www.worldpumps.com 31


feature pumping with low NPSH

oxygen supply is inadequate? This is energy tax) at 40 gpm. The velocity instrumentation on the equipment. But
like the US National Highway Traffic through the 2” pipe is 3.82 ft/s. It is sadly, the process engineers and
Safety Administration establishing an 11.4% energy tax (Kf = 11.4) at 80 operators don’t even know what
the rule that the automobile bumper gpm with the velocity at 7.65 ft/s, and information they need to resolve
must withstand a 5 mph (8 km/h) a 43% energy tax at 160 gpm with the problems in the pumps. And other
impact with no damage. Tremendous velocity at 15.3 ft/s in a 2” pipe. We process personnel wouldn’t know how to
if you don’t drive more than 5 mph. can observe that the energy losses interpret the information if they had it.
When was the last time that you drove (Kf) are modest at 5 to 8 ft per second So, we pretend that most pump failure is
to work or the grocery store at 5 mph? ... and 4 ft/s is better than 5 etc. In a a surprise, unexpected, unanticipated
How about a more realistic value? perfect world the fluid velocity would event. The mechanics think the
only be fast enough to prevent solids operators are abusing the pumps. The
Pump users are demanding NPSHR from settling and forming an operators think the mechanics don’t
values reflecting zero loss of pump obstruction in the pipe, or to meet a know how to adequately rebuild the
performance, and higher NPSHA safety or practical need. pumps. And management decides to
safety margins. The manufacturers are solve the problem by sending everyone
crying that the new values will be Watch for new published literature to a bearing installation class.
prohibitively excessive and impossible indicating that the criteria for NPSH
to meet. It’s somewhat akin to has changed, along with the expected As a pump lecturer and trainer, I
declaring that all SUVs should unhappy reaction from the pump always spend time covering these
immediately get the gasoline mileage manufacturers, system specifiers and points so that the operators
of a compact passenger car. purchasing agents. The Pump Guy is understand the gauges and meters of
in favour of this and believes that we their profession, and can give the best
Another issue is the fact that written need more realistic values. That is, information to the maintenance
pump literature normally lists the unless you like to continually rebuild engineers and technicians, who will
NPSHR value at BEP, the best efficiency and repair pumps. do the repairs. I encourage all
point. This is the value used by pump supervisors, bosses and foremen to go
salesmen to sell a pump. This is the over these points with your mechanics
value used to compare competing pumps Monitoring NPSHA and operators. We’re all charged with
for purchase. However, the BEP is reducing downtime, stopping leaks,
practically never the actual duty point of Remember that the NPSHR is listed on conserving energy and doing more
a pump. The operator normally has most family pump curves. The NPSHA with less people.
absolutely no idea where his pump is can be closely approximated by simply
operating on its curve… because he observing the pumping system. And, the In about 80% of what you perceive as
doesn’t have, or doesn’t interpret, the NPSHA can be precisely measured with unscheduled downtime, emergency
instrumentation. So what happens? some simple instrumentation. In- maintenance, the pump was telling
adequate NPSHA can be interpreted you the problem for hours, days and
As the pump moves on its curve out to with instrumentation on the pump even weeks before the breakdown
the right of the BEP the NPSHR rises suction nozzle and piping. Please include event occurred. If you’re responsible
exponentially. One of the elements of some training on how to do this. for pump maintenance, keep this
the NPSHA is the Hf (friction head), column or store this magazine where
which robs (subtracts) energy from the Remember that all premature failure in you can find it quickly. It is your cheat
fluid. The Hf rises by the square of the an industrial pump is induced by one of sheet of useful pump info. ■
increase in velocity and flow, so twice three factors. There is maintenance-
the flow is four times the Hf, and as the induced premature failure. There is CONTACT
flow and turbulence increases dissolved operations-induced premature failure. The Pump Guy is Larry Bachus, a pump
consultant, lecturer and inventor based
air can come out of the liquid. In this And, there is design-induced premature in Nashville, Tennessee. He is a member
sense, if the published NPSHR is the failure. Pump problems resulting from of ASME and lectures in both English
value at the BEP, and the pump is inadequate suction piping would be a and Spanish. He can be contacted at:
Tel: +1-615-361-7295;
operating to the right of the BEP on its design-induced failure. That usually Fax: +1-615-366-0040;
curve, then are the criteria actually means the person who specifies the E-mail: larry@bachusinc.com
being met? Probably not. piping at the construction phase, or the
person who authorizes a change to the All these points are covered
Over the years, I’ve come to view the piping arrangement after the plant is thoroughly in the book co-authored
friction constant on a pipe schedule commissioned. by Larry Bachus entitled Know and
as a type of energy tax. Consulting Understand Centrifugal Pumps
the HI value for 2” schedule 40 In my experience, I find that most (ISBN 1856174093), which is
carbon steel pipes, the friction instrumentation technicians are ready published by Elsevier Science.
constant (Kf) is 3.10 (call it 3.10% and waiting to install the adequate

32 www.worldpumps.com WORLD PUMPS March 2004