B3 BCSI-B3 SUMMARY SHEET - PERMANENT RESTRAINT/BRACING OF CHORDS & WEB MEMBERS

Spans over 60’ may require complex permanent bracing. Please always consult a Professional Engineer. B3

Copyright © 2004-2007 WTCA – Representing the Structural Building Components Industry and Truss Plate Institute. All Rights Reserved. This guide or any part thereof may not be reproduced in any form without the written permission of the publishers. Printed in the United States of America.
WARNING! Disregarding Permanent Restraint/Bracing is a major cause of truss field performance  Use rows of continuous Lateral Restraint with Diagonal Bracing, gypsum board sheathing or ALWAYS DIAGONALLY BRACE THE CONTINUOUS LATERAL RESTRAINT! Gable End Frames and Sloped Bottom Chords
problems and has been known to lead to roof or floor systems collapse. rigid ceiling. ¡SIEMPRE ARRIOSTRE LA RESTRICCIÓN LATERAL CONTINUA DIAGONALMENTE! Armazones Hastiales Y Cuerdas Inferiores Pendientes
¡ADVERTENCIA! Descuidar el Arriostre/Restricción Permanente es una causa principal de prob- Use filas de Restricción Lateral Continua (CLR) con Arriostre Diagonal o entablado de yeso o B. Individual Web Member Reinforcement  The Gable End Frame should always match the profile of the adjacent trusses to permit installation
lemas de rendimiento del truss en campo y había conocido a llevar al derrumbamiento del sistema techo rigído. B. Refuerzo de Miembros Segundarios Individuales of proper Bottom Chord Plane restraint & bracing.
del techo o piso. T-, L-, Scab, I-, U-Reinforcement, proprietary metal reinforcement and stacked web products provide an El Armazón Hastial siempre debe encajar el perfil de los trusses contiguos para permitir la insta-
 The TDD provides information on the assumed support for the bottom chord. alternative for resisting web buckling. lación de Restricción y Arriostre de la Cuerda Inferior apropiada.
WARNING! Spans over 60’ may require complex permanent bracing. Please always consult a El TDD provee información sobre el soporte supuesto para la cuerda inferior.
Professional Engineer. T-, L-, costra, U-Refuerzo, refuerzo de metal patentando y productos de miembros segundarios
amontonados proveen una alternativa para resistir el torcer de los miembros segundarios.

This document summarizes the information provided in Section B3 of the 2006 Edition of Building Component Safety Information BCSI - Guide to Good Practice for Handling, Installing, Restraining & Bracing of Metal Plate Connected Wood Trusses.
¡ADVERTENCIA! Vanos más de 60 pies pueden requerir arriostre permanente complejo. Por favor, Install bottom chord permanent Lateral Restraint at the spacing indicated on the TDD

Bottom
siempre consulte a un Ingeniero Profesional. and/or by the Building Designer with a maximum of 10’ on center.
chord
RESTRAINT/BRACING MATERIALS & FASTENERS Instale Restricción Lateral permanente de la cuerda inferior al espaciamiento indicado plane
en el TDD y/o por el Diseñador del Edificio con un máximo de 10 pies en el centro.
MATERIALES Y CIERRES DE RESTRICCIÓN/ARRIOSTRE
 Common restraint/bracing materials include wood structural panels, gypsum board sheathing, Diagonal
stress-graded lumber, proprietary metal products, and metal purlins and straps. Diagonal Bracing
Materiales comunes de arriostrar/restringir incluyen paneles estructurales de madera, entablado de yeso,
Bracing Example of raked gable end wall
madera graduada por esfuerza, productos de metal patentados, y vigas de soporte y tiras de metal. (with scissors Gable End Frame)
Bottom Chords
MINIMUM ATTACHMENT REQUIREMENTS FOR LUMBER RESTRAINT/BRACING1,2 Truss Member, typ.
Lumber Size Minimum Nail Size Minimum Number of  The following table may be used unless more specific information is provided.
Nails per Connection La siguiente tabla puede ser usada a menos que información más específica está provisto. Warning! – Do not install a flat bottom chord Gable End Frame with adjacent trusses that have
a sloped bottom chord. Adequate bracing of this condition is very difficult and often impossible.
2x4 stress-graded 10d (0.128x3”) web reinforcement for single ply trusses 1
¡ADVERTENCIA! No instale un Armazón Hastial de cuerda inferior plana con trusses contiguous que
12d (0.128x3.25”) 2 Lateral Restraint 2x4x12' tienen una cuerda inferior pendiente. Arriostre adecuado de esta
16d (0.131x3.5”) ≤10' ≤20' or greater lapped over condición es muy difícil y a menudo imposible.
≤10' two trusses
2x6 stress-graded 10d (0.128x3”)
≤10' PERMANENT BRACING FOR SPECIAL CONDITIONS
12d (0.128x3.25”) 3
≤10' Some chord and web members not ARRIOSTRE PERMANENTE PARA CONDICIONES
16d (0.131x3.5”)
shown for clarity. ESPECIALES
1
Other attachment requirements may be specified by the Truss Designer or Building Designer. Sway Bracing—Arriostre de “Sway”
The size and attachment for bracing materials such as wood structural panels, gypsum board sheathing,  “Sway” bracing is installed at the discretion of the Building
2
Lateral Restraint and Diagonal Bracing used to brace the Bottom Chord Plane.
proprietary metal restraint/bracing products, and metal purlins and straps are provided by the Building Designer.
Designer to help stabilize the truss system and minimize the
3. PERMANENT BRACING FOR THE WEB MEMBER PLANE lateral movement due to wind and seismic loads.
PERMANENT BRACING FOR THE VARIOUS PLANES OF A TRUSS 3. ARRIOSTRE PERMANENTE PARA EL PLANO DE MIEMBRO SECUNDARIO Arriostre de “Sway” está instalado por la discreción del
Web Member Permanent Bracing collects and transfers buckling restraint forces and/or lateral loads Diseñador del Edificio para ayudar en estabilizar
ARRIOSTRE PERMANENTE PARA VARIOS PLANOS DE UN TRUSS from wind and seismic forces. The same bracing can often be used for both functions. el sistema del trusses y para minimizar el
Top Chord
 Permanent Bracing is important because it, Arriostre Permanente de los Miembros Segundarios recogen y pasan fuerzas de restricción de movimiento lateral debido a cargas de viento y
Plane
a) prevents out-of-plane buckling of truss torcer y/o cargas laterales de viento y fuerzas sísmicas. A menudo el mismo arriostre puede ser cargas sísmicas.
members, Web usado para ambos funciones. PERMAnEnT LATERAL REsTRAinT REQUiRED
 Sway bracing, if continuous, also serves to

pLb 20070109
www.tpinst.org
b) helps maintain proper truss spacing, and
See TruSS DeSign Drawing for Specific informaTion

Member  Some Truss Manufacturers mark the locations of the web Lateral

wTca – representing the Structural building components industry & Truss plate institute
c) resists and transfers lateral loads from Plane Individual Web Member Permanent Restraint & Bracing distribute gravity loads between trusses of
Restraint or reinforcement on the truss using tags similar to those

all rights reserved


PLATE HERE
wind and seismic forces. Restricción y Arriostre Permanente de Miembros Secundarios Individuales varying stiffness.
at left.

copyright © 1992-2007
Arriostre Permanente es importante  Check the TDD to determine which web members (if any) require restraint to resist buckling. Arriostre de “Sway,” si es continuo, también es
Algunos Fabricantes de Trusses marcan en el truss las ubicaciones
Revisa el TDD para determinar cuales miembros segundar- usado para distribuir las cargas de gravedad

www.sbcindustry.com
porque, Vea Dibujo De DiSeño De TruSS para información eSpecífica

REsTRicción LATERAL PERMAnEnTE REQUERiDO de refuerzo o Restricción Lateral de miembros secundarios usando
a) impide el torcer fuera-de-plano de los ios (si algunos) requieren restricción para resistir el torcer. One restraint required on
entre trusses de rigidez variando. Continuous “sway” or “X” bracing
each of these webs. etiquetas similares a las a la izquierda.
miembros del truss, Una restricción es requerida WEB REINFORCEMENT REQUIRED Permanent Restraint/Bracing for the Top along the length of the building
 Restrain and brace with,

WEBREINF 20060409
en cada de estos miembros
Chord in a Piggyback Assembly

www.tpinst.org
SEE TRUSS DESIGN DRAWING FOR SPECIFIC INFORMATION

b) ayuda en mantener espaciamiento A. Continuous Lateral Restraint & Diagonal Bracing, or segundarios.

WTCA – Representing the Structural Building Components Industry & Truss Plate Institute
apropiado de los trusses, y Restricción/Arriostre Permanente para la

All Rights Reserved


PLATE HERE
B. Individual Member Web Reinforcement. T, L OR SCAB
Fasten OSB to framing Cuerda Superior en un Ensamblaje de Piggyback
c) resiste y pasa las cargas laterales de Bottom Chord Restrinja y arriostre con,
REINFORCEMENT

Copyright © 1992-2006
T, L o REFUERZO
@ 3" o.c. on edge, 6"  Provide restraint and bracing by:
viento y fuerzas sísmicas aplicadas al Plane A. Restricción Lateral Continua y Arriostre Diagonal, o
DE SCABS
Repeat Diagonal
Block sheeting o.c. in field with 8d 2x4 SYP outrigger at 24" on

www.sbcindustry.com
sistema del truss.
VEA DIBUJO DE DISEÑO DE TRUSS PARA INFORMACIÓN ESPECÍFICA
7/16 OSB edges within 4' • using rows of 4x2 stress-graded lumber Bracing at 10'
B. Refuerzo de Miembros Segundarios Individuales. REFUERZO DE MIEMBRO SECUNDARIO REQUERIDO center. Clip to Gable Top Chord CLR and Diagonal
of Gable Truss intervals or less,
 Trusses require Permanent Bracing within ALL of the following planes:
with HB w/(10) 8d.
A. Continuous Lateral Restraint (CLR) Bracing, or as specified. CLR at
1. Top Chord Plane & Diagonal Bracing Web Member Plane • connecting the CLR into the roof spacing
2. Bottom Chord Plane A. Restricción Lateral Continua (CLR) y Arriostre Diagonal Permanent Building Stability Block between outlookers. Fasten diaphragm, or
to Gable Top Chord w/ 10d Toe-nails specified
3. Web Member Plane Structural  Attach the CLR at the locations shown on the TDD. Bracing to Transfer Wind & • adding Structural Sheathing or Bracing
@ 8" o.c. on the
Trusses requieren Arriostre Permanente Sheathing on Sujete el CLR en las ubicaciones mostrados en el TDD. Seismic Forces Frames, or
2x4 No. 2 SYP Gable Top Chord Truss Design
dentro de TODOS los siguientes planos: Top Chord  Install the Diagonal Bracing at approximately 45° to the CLR and extend from the top chord to the Arriostre de Estabilidad X-bracing at • some other equivalent means.
L-Reinforcement on Gable Drawing
1. Plano de la Cuerda Superior Plane bottom chord, attaching to each web that it crosses. Repeat every 20’ or less. Please thoroughly Permanente del Edificio mid-span and at Provee restricción y arriostre por:
Verts as specified by Truss
2. Plano de la Cuerda Inferior check all Construction Documents as closer spacing may be required. del Plano de Miembros 48" o.c. run back
Manufacturer. • usando filas de 4x2 CLR madera graduada
Secundarios para Desplazar 8' from gable.
3. Plano del Miembro Secundario Instale el Arriostre Diagonal a aproximadamente 45 grados al CLR y extiende de la cuerda superior Attach to gable Gable Truss por esfuerza
a la cuerda inferior, sujetando a cada miembro segundario que lo cruza. Repita cada 20 pies o Fuerzas de Viento y Fuerzas and truss verticals If vertical is not present, scab y Arriostre Diagonal, o
WARNING! Without Permanent Bracing menos. Por favor revisa con cuidado todos los Documentos de Construcción porque espaciamiento Sísmicas w/(3) 16d. full height vertical from Bottom • conectando el CLR al diafragma del
the truss, or a portion of its members, más cercano puede ser requerido.  The web member restraint Chord to Top Chord w/(4) 10d techo, o
will buckle (i.e., fail) at loads far less than or reinforcement specified on each end. (TYP)
• añadiendo Entablado Estructural o arm
design. EXAMPLES OF DIAGONAL BRACING WITH CONTINUOUS a TDD is required to resist 2x4x8' SYP Lateral Strap Gable Truss
Clip end of Lateral Restraint zones de arriostre, o algunos otros métodos equivalentes.
buckling under vertical loads. to Gable Bottom Chord with
¡ADVERTENCIA! Sin Arriostre Permanente LATERAL RESTRAINT Restraint @ 48". to stud wall with (2) H2.5 w/(8) 8d.
Additional restraint and bracing Fastened to each MSTA12 with (8)  Refer to the TDD for the maximum assumed spacing for attaching the Lateral Restraint to the top
el truss, o un parte de los miembros, Continuous
Lateral Restraint Permanent Continuous is typically required to transfer truss w/ (2) 16d 10d @ 48" o.c. Gable Bottom Chord. chord of the supporting truss.
torcerán (ej. fallarán) de cargas muchas Lateral Restraint Fasten to top plate w/ 10d
lateral loads due to wind and/or common. Refiere al TDD para el espaciamiento máximo supuesto para sujetar la Restricción Lateral o en-
menos que las cargas que el truss es toe-nails @ 8" o.c.
Diagonal seismic forces. This restraint tablado a la cuerda superior del truss soportante.
diseñado a llevar.
≈45˚ Bracing and bracing is typically provided  The TDD provides the assumed thickness of
1. PERMANENT BRACING FOR THE by the Building Designer.
TOP CHORD PLANE ≈45˚ Diagonal Brace to roof Diaphragm blocking Cap the restraint and minimum connection require-
La restricción o refuerzo de miembros ments between the cap and the supporting truss
1. ARRIOSTRE PERMANENTE PARA EL Trusses
segundarios especificada en un TDD es Gable End or restraint.
PLANO DE LA CUERDA SUPERIOR Purlins
requerido a resistir el torcer bajo cargas Frame
 Use plywood, oriented strand board (OSB), or ≤20' verticales. Restricción y arriostre adicional Roof CLR required only El TDD provee el grosor supuesto de la restric-
wood or metal structural purlins that are properly es requerido típicamente para pasar cargas Diaphragm ción y los requisitos de conexión mínimos entre
if Bracing Frame or
braced. laterales debidas a fuerzas de viento y/o Blocking la capa y el truss soportante o la restricción.
Structural Sheath-
Use contrachapado, panel de fibras orientadas Note: Some chord and web members not fuerzas sísmicas. Esta restricción y arriostre ing is installed
(OSB), o vigas de soporte de madera o metal que shown for clarity.  If Diagonal Bracing is used to restrain the
es típicamente provisto por el Diseñador del Horizontal intermittently
son arriostrados apropiadamente. Group of 3 Trusses Edificio. L- Reinforcement
CLR(s), repeat at 10’ intervals or as speci-
Bracing Frame fied. Please thoroughly check all Construction
 The Truss Design Drawing (TDD) provides infor- or Structural Documents as closer spacing may be required.
mation on the assumed support for the top chord. Diagonal “X” bracing in the Top Chord Plane at intervals Diagonal Brace Sheathing Si Arriostre Diagonal es usado para restringir
El Dibujo del Diseño de Truss (TDD) provee specified by the Building Designer Diagonal Bottom Chord Supporting el/los CLR(s), repita en intervalos de 10 pies
información sobre el soporte supuesto para la
Lateral Restraint
Brace Lateral Restraint Trusses o como especificado. Por favor revisa con
cuerda superior. Blocking cuidado todos los Documentos de Construcción
Attach Gable end/wall permanent Diagonal Bracing. porque espaciamiento más cercano puede ser
 Fastener size and spacing requirements and grade for the
Diagonal Locate in line with Bottom Chord permanent requerido.
sheathing, purlins and bracing are provided in the build- CLR or as specified by the Building Designer.
Brace to
ing code and/or by the Building Designer.
Blocking
El tamaño de cierre y requisitos de espaciamiento y Note: Top Chord
grado para el entablado, vigas de soporte y arriostre son Group of 2 Trusses sheathing not shown
provistos en el código del edificio y/o por el Diseñador Lateral Restraint for clarity.  Some Truss Designers provide general design tables
del Edificio. and details to assist the Building Designer in determin-
 Lateral Restraint & Diagonal Bracing can also be used with small groups of trusses (i.e., three or ing the Bracing required to transfer lateral loads due to
2. PERMANENT BRACING FOR THE BOTTOM Directly wind and/or seismic forces from the Gable End Frame into the roof and/or ceiling diaphragm. Truss Plate Institute
attached less). Attach the Lateral Restraint & Diagonal Brace to each web member that they cross.
CHORD PLANE Algunos Fabricantes de Trusses proveen tablas y detalles de diseño generales para asistir el Diseña- 6300 Enterprise Lane • Madison, WI 53719 218 N. Lee St., Ste. 312 • Alexandira, VA 22314
rigid Restricción Lateral y Arriostre Diagonal también puede ser usado con grupos pequeños de trusses
2. ARRIOSTRE PERMANENTE PARA EL PLANO ceiling (ej. tres o menos). Sujete la Restricción Lateral y el Arriostre Diagonal a cada miembro segundario dor del Edificio en determinar el Arriostre requerido para pasar cargas laterales debidas a fuerzas 608/274-4849 • www.sbcindustry.com 703/683-1010 • www.tpinst.org
DE LA CUERDA INFERIOR que los cruzan. de viento y/o fuerzas sísmicas del Armazón Hastial al diafragma del techo.
B3WEB11x17 070209

Restricción/Arriostre Permanente de las Cuerdas y los Miembros Secundarios


Vanos más de 60 pies pueden requerir arriostre permanente complejo. Por favor, siempre consulte a un Ingeniero Profesional.