Você está na página 1de 3

MASTERTOP® PRIMER 9

Formerly Conipox 601


Epoxy primer for substrate in contact with subsoil

DESCRIPTION Certified to operate Certified to prevent osmosis


under rising damp and to achieve good adhesion
MASTERTOP PRIMER 9 is a solvent free 2 component conditions and under rising damp conditions
epoxy-primer. Mastertop 1206 is a very low viscosity and backpressure and backpressure.
therefore exhibits a high capillary penetration. The
material is easy to apply and forms an effective moisture TYPICAL PERFORMANCE DATA
barrier. When fully cured, Mastertop Primer 9 exhibits
good mechanical properties and excellent adhesion (7 days cure @ 20oC
2
under rising damp and backpressure conditions. Compressive strength (DIN 1164) : 80N/mm
MASTERTOP PRIMER 9 is resistant to a wide spectrum 2
Tensile strength (DIN 53504) : 28 N/mm
o chemicals. 2
MASTERTOP PRIMER 9 is in compliance with: Bond strength (DIN ISO 4624) : < 2.5 N/mm
Cert No. Institute Classification Remarks Coeff. of linear expansion : 70X10K-1
Norm
OS-F Shore D Hardness : 84
P 592a DAR passed
cert. Service Temperature : -20oC to 60oC
OS-8
P 710-2 DAR passed Application temperature : Min 10
cert.
Federal Max. 35
FDH and
Health
FCH P 896-C DAR passed
approval
Centre PROPERTIES
(Germany)
Backpres
Ingeniofir a. Components
mat Olav passed 10 bar
sure Supply Density
Skalvollas Colour
Adhesion Form kg/L
under No MASTERTOP
Adhesion liquid amber 1.10
rising P 1588 DAR blisters 2
3.1 N/mm PRIMER 9 Part A
damp m0/g0
conditions MASTERTOP
liquid amber 1.05
PRIMER 9 Part B
RECOMMENDED FOR b. Mixed systems
MASTERTOP PRIMER 9 is used as a pore and Mix ratio by
Components
capillary-sealing primer on mineral substrates such as weight
concrete and cement mortar-screeds and complies with MASTERTOP A:B 100:27
the regulations concerning applications under conditions PRIMER 9
where rising damp, osmosis or backpressure could
occur. It is ideal as primer for:
• mineral substrates in contact with sub soil. Pot-life (minutes)
• substrates where rising damp/osmosis could be o o o
present @10 C @ 20 C @30 C
• where no vapour barrier is installed MASTERTOP
• where the substrate is a poor quality PRIMER 9
60 30 20

FEATURES AND BENEFITS Curing time (days)


o o o
Good tolerance to Avoids expensive surface @10 C @ 20 C @30 C
moist concrete preparation to achieve 100%
MASTERTOP
dry substrates. 7 3 2
PRIMER 9
Excellent Streghtens, improves quality of
penetration into poor substrates
surface

Head Office Factories Representative Offices


Plaza GRI 10th & 11th Floor Jl. Daan Mogot Km.14 Jl. Jababeka V Blok I-1 Grand Residence Office Park, Komp. Pertokoan Royal Sunggal
Jl. HR Rasuna Said Blok X-2 No.1 Cengkareng, Cikarang Industrial Estate 1st Floor Jl. Gagak Hitam No. A-12
Jakarta 12950 Jakarta 11750 Bekasi 17530 Jl. Darmo Harapan Complex 1 Ring Road – Sunggal
Tel.: (6221) 5262481, 5262505 Tel.: (6221) 6190007 Tel.: (6221) 8934339 Surabaya 60187 Medan, Sumatera Utara 20128
Fax: (6221) 5262493, 5262515 Fax: (6221) 6190741 Fax: (6221) 8934342 Tel.: (6231) 7326705 Tel.: (6261) 8447110
Fax: (6231) 7326730 Fax: (6261) 8444072
MASTERTOP® PRIMER 9
Maximum permissible relative humidity Continue to mix and add 2 to 3 bags of F1 filler until a
homogenous and uniform mix is obtained.
o o
@ 10 C At > 23 C
Placing
All components 75 % 90 % Depending on the substrate condition, apply. 2.0 to 2.5
kg.m2 of the mix; pour out the whole mix at once into
pours being approximately 200 to 300 mm wide running
APPLICATION parallel to the work direction. Make good the uneven
Surface preparation surface by skimming over the surface with a steel trowel,
The compressive strength of the substrates shall not be filling up only the depressions and imperfections.
less than 30N/mm2. The substrates in contact with the
ground must have a vapour barrier installed in
COVING/REPAIR MORTAR
compliance with DIN 18195 or equivalent, or be primed Mixing
with MASTERTOP PRIMER 9. The moisture content of Use a low speed Mortar mixer. Premix one unit of
substrate shall be not higher than 8% throughout) test MASTERTOP PRIMER 9 Part A with one unit of
using CM equipment). The temperature of the substrate MASTERTOP PRIMER 9 Part B for at least 3 minutes
must be at least 3oC above the current dew point until the mix is uniform and free of streaks then add 5 to
temperature. Correct substrate preparation is critical for 10 bags of Filler F2 under constant mixing.
optimum performance. Surfaces must be structurally
sound, clean and free from loose particle, oil, grease, Placing
and all other contaminants. Remove oil, grease and wax The mix must be applied to the freshly primed
contaminants by scrubbing with industrial grade substrate. For repairs of holes large depressions etc.
detergent or degreasing compounds followed by apply the mix with steel trowel. Covings are best
mechanical cleaning. Cement laitance, loose particles, formed with a coving tool or empty bottle.
mould release agents, curing membranes and other Following the application of the MASTERTOP PRIMER
contaminants must be removed from the surface by 9, protect coated area for at least 24 hours after laying
shot-blasting, Blastrac® , scarifying or grit-blasting from spillage, dust, insects, small animals, traffic, rain,
followed by vacuum cleaning. After pre-treatment of the moisture, etc.
substrate, the bond strength of the substrate must be at
least 1.5N/mm2 (check with an approved pull-of tester, CLEANING
load rate 100N/s). fill the surface irregularities such as
Clean tools and equipment first with paper towels or
blowholes, cracks, honeycombs, etc. with an Emaco® rags, then wipe using a solvent such acetone or methyl-
repair mortar to achieve a smooth and level surface. iso-butyl ketone before the resin system hardens.
Protect walls and columns against resin splashes using
masking tape and polythene sheeting. ESTIMATING DATA
Mixing
Use a low speed (300 rpm) electric drill fitted with apaint 2
System Product Kg/m Thickness
mixer or a wing type paddle. Premix one unit of
mm
MASTERTOP PRIMER 9 Part A with one unit of
MASTERTOP PRIMER 9 Part B for at least 3 minutes MASTERTOP 0.4 - 0.6 0.3 – 0.4
until the mix is uniform and free of streaks. Primer PRIMER 9
Placing
Immediately after mixing, pour the material onto the PACKAGING
substrate and spread the mixed material using a
squeegee or paint roller. The primary purpose of this MASTERTOP PRIMER 9 30.0kg/set
primer coat is to seal the substrate completely an avoid Filler F5 25.0kg/set
air-bubbles in the body coat. On very porous substrates,
Filler F2 25.0kg.set
a second primer sealer coat may be required. If in doubt,
apply a sample patch of body coat. SHELF LIFE
Broad casting of sand All components in MASTERTOP PRIMER 9 can be kept
F5 filler is broadcast at the rate of 0.8 10 1.0 kg/m2 onto for 12 months in original unopened packing, if stored in a
the wet primer; do not sand in excess. Placing of the of dry enclosed place without exposing to direct sunlight
the wet primer unsanded surfaces outside the recoating o
and at temperature between 15 to 35 C.
interval will lead to interlayer failures (de-bonding).

SCRATCH PRIMER
Mixing
Use a low speed (300 rpm) electric drill fitted with apaint
mixer or a wing type paddle. Premix one unit of
MASTERTOP PRIMER 9 Part A with one unit of
MASTERTOP PRIMER 9 Part B for at least 3 minutes
until the mix is uniform in colour and free of streaks.
MASTERTOP® PRIMER 9
PRECAUTIONS
MASTERTOP PRIMER 9 contains certain chemicals
which can cause skin irritation if exposed and respiratory
reaction if inhaled. Wear gloves, mask and use hand
barrier cream while handling the product. Wash
thoroughly after handling.
Should skin contact occur, wash immediately with soap
and water or an effective hand cleaner.
In case of accidental eye contact, wash with copious
quantity of water and immediately seek medical advice.
If ingested, do not induce vomiting. Consult doctor
immediately.
Vapours of solvents used fro cleaning can be irritating. It
is therefore recommended that cleaning be done well-
ventilated areas.
Fire: Keep away from sources of ignition. Do not smoke
whilst handling the product.
For detailed Health, Safety and Environmental
Recommendations, please consult and follow all
instructions on the product Material Safety Data Sheet.
MT P9/01/0800

The technical information and application advice given in this BASF Construction Chemicals
publication are based on the present state of our best scientific and practical knowledge. As the
STATEMENT OF information herein is of a general nature, no assumption can be made as to a product's suitability for a
RESPONSIBILITY particular use or application and no warranty as to its accuracy, reliability or completeness either
expressed or implied is given other than those required by law. The user is responsible for checking the
suitability of products for their intended use.
Field service where provided does not constitute supervisory responsibility. Suggestions made by
BASF Construction Chemicals either orally or in writing may be followed, modified or rejected by the
NOTE owner, engineer or contractor since they, and not BASF Construction Chemicals, are responsible for
carrying out procedures appropriate to a specific application.

Você também pode gostar