Você está na página 1de 1270

PRS

V100R015C10

Performance Report Reference

Issue 01
Date 2015-05-30

HUAWEI TECHNOLOGIES CO., LTD.


Copyright © Huawei Technologies Co., Ltd. 2015. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior written
consent of Huawei Technologies Co., Ltd.

Trademarks and Permissions

and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective holders.

Notice
The purchased products, services and features are stipulated by the contract made between Huawei and the
customer. All or part of the products, services and features described in this document may not be within the
purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information,
and recommendations in this document are provided "AS IS" without warranties, guarantees or representations
of any kind, either express or implied.

The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.

Huawei Technologies Co., Ltd.


Address: Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China

Website: http://www.huawei.com
Email: support@huawei.com

Issue 01 (2015-05-30) Huawei Proprietary and Confidential i


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference About This Document

About This Document

Overview
This section describes the counters and meanings of the predefined report templates of the
PRS.

Product Version
The following table lists the product version related to this document.

Product Name Product Version

PRS V100R015C10

Intended Audience
This document is intended for network planning engineers and network management engineers.

Change History
01 (2015-05-30)
This issue is the first official release of iManager PRS V100R015C10. Compared with Draft A
(2015-03-10), this issue has no changes.

Draft A (2015-03-10)
This issue is the first release of the iManager PRS V100R015C10 beta version.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential ii


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference Contents

Contents

About This Document.....................................................................................................................ii


1 ASNGW Performance Report.....................................................................................................1
1.1 ASNGW NE Report.......................................................................................................................................................2

2 BSC32 NHC Report.....................................................................................................................30


2.1 High Call Drop Rate Cell(Night Busy Time)...............................................................................................................31
2.2 High Call Drop Rate Cell(Morning Busy Time)..........................................................................................................31
2.3 High Congestion Rate Cell(Night Busy Time).............................................................................................................32
2.4 High Congestion Rate Cell(Morning Busy Time)........................................................................................................33
2.5 Traffic Volume Measurement......................................................................................................................................34
2.6 Cell Performance Measurement(Night Busy Time).....................................................................................................34
2.7 Cell Performance Measurement(Morning Busy Time)................................................................................................35

3 BSC32 Performance Report........................................................................................................37


3.1 BSC KPI Report...........................................................................................................................................................38
3.1.1 Retainability Report...................................................................................................................................................38
3.1.2 Service Quality Report..............................................................................................................................................39
3.1.3 Accessability Report..................................................................................................................................................49
3.1.4 Mobility Report.........................................................................................................................................................50
3.1.5 Availability Report....................................................................................................................................................53
3.2 Special Cell Report.......................................................................................................................................................54
3.2.1 Busy Cell Report.......................................................................................................................................................54
3.2.2 Idle Cell Report.........................................................................................................................................................58
3.2.3 Hot Cell Report..........................................................................................................................................................62
3.2.4 Worst Cell Report......................................................................................................................................................66
3.3 Cell KPI Report............................................................................................................................................................70
3.3.1 Retainability Report...................................................................................................................................................70
3.3.2 Service Quality Report..............................................................................................................................................71
3.3.3 Accessability Report..................................................................................................................................................81
3.3.4 Mobility Report.........................................................................................................................................................82
3.3.5 Availability Report....................................................................................................................................................84
3.4 Cell TopN Report.........................................................................................................................................................85
3.4.1 BSC Handover Success Rate Report.........................................................................................................................86

Issue 01 (2015-05-30) Huawei Proprietary and Confidential iii


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference Contents

3.4.2 Call Setup Success Rate Due to BSS Report.............................................................................................................87


3.4.3 SDCCH Available Rate Report.................................................................................................................................88
3.4.4 SDCCH Congestion Rate Report..............................................................................................................................89
3.4.5 TCH Call Drop Rate(including handovers) Report...................................................................................................89
3.4.6 TCH Available Rate Report......................................................................................................................................90
3.4.7 TCH Traffic Volume per Channel Report.................................................................................................................91
3.4.8 TCH Quality Identifier Report..................................................................................................................................92
3.4.9 TCH Attempt Failure Rate Due to No TCH Assignment Report............................................................................102
3.4.10 TCH Seizures Success Rate Report.......................................................................................................................103
3.4.11 TCH Assignment Success Rate Report.................................................................................................................104
3.4.12 Immediate Assignment Success Rate Report........................................................................................................104

4 GSM BSS NHC Report.............................................................................................................106


4.1 High Call Drop Rate Cell(Night Busy Time).............................................................................................................107
4.2 High Call Drop Rate Cell(Morning Busy Time)........................................................................................................108
4.3 High Congestion Rate Cell(Night Busy Time)...........................................................................................................109
4.4 High Congestion Rate Cell(Morning Busy Time)......................................................................................................110
4.5 Traffic Volume Measurement....................................................................................................................................111
4.6 Cell Performance Measurement(Night Busy Time)...................................................................................................111
4.7 Cell Performance Measurement(Morning Busy Time)..............................................................................................113

5 GSM BSS Performance Report...............................................................................................116


5.1 Average Sending Throughput Rate Report................................................................................................................117
5.1.1 LGCPRT MEAN TXRATE Report........................................................................................................................117
5.1.2 MLPPP TXMEANSPEED Report..........................................................................................................................117
5.1.3 PPP TXMEANSPEED Report................................................................................................................................118
5.2 Local Switch Report...................................................................................................................................................119
5.2.1 BSC LCLS USER RATE Report............................................................................................................................119
5.2.2 SITE CS USED TS RATE Report..........................................................................................................................120
5.2.3 SITE LCLS USER RATE Report...........................................................................................................................120
5.3 Service Identification Qos Report..............................................................................................................................121
5.3.1 Cell Performance KPI Report..................................................................................................................................121
5.3.2 PDCHs Occupied by TBF Performance Analysis Report.......................................................................................124
5.3.3 Signaling Performance Analysis Report..................................................................................................................127
5.3.4 Throughput Performance Analysis Report..............................................................................................................130
5.4 VAMOS Performance Report....................................................................................................................................136
5.4.1 Handset Type Influence to VAMOS analysis Report.............................................................................................136
5.4.2 VAMOS Call Drop Ratio Analysis Report.............................................................................................................137
5.4.3 VAMOS Influence to Network Total Performance Analysis Report......................................................................140
5.4.4 VAMOS Radio Handover Success Ratio Analysis Report.....................................................................................141
5.5 BSC KPI Overview Report.........................................................................................................................................143
5.6 GSM BSC KPI Report................................................................................................................................................168
5.7 GSM Network Performance Monitoring Report (Engineer)......................................................................................170

Issue 01 (2015-05-30) Huawei Proprietary and Confidential iv


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference Contents

5.8 GSM Network Performance Monitoring Report (Team Leader)...............................................................................209


5.9 Retainability Report....................................................................................................................................................214
5.10 Extra Busy Cell Report.............................................................................................................................................215
5.11 Extra Idle Cell Report...............................................................................................................................................216
5.12 Call Drop Cell Report...............................................................................................................................................217
5.13 Accessibility Report.................................................................................................................................................218
5.14 Whole Network KPI Report.....................................................................................................................................220
5.15 Mobility Report........................................................................................................................................................223
5.16 Congestion Cell Report............................................................................................................................................226
5.17 Resource Utilization Report.....................................................................................................................................226
5.18 Worst Cell Report.....................................................................................................................................................229
5.19 BTS Energy Consumption Report............................................................................................................................230
5.19.1 BTS Traffic and Energy Consumption Report......................................................................................................230
5.19.2 Network Energy Efficiency Indicator Report........................................................................................................232

6 GU SingleRAN Performance Report.....................................................................................234


6.1 Relate Report..............................................................................................................................................................235
6.1.1 GSM Interoperations Report...................................................................................................................................235
6.1.2 UMTS Interoperations Report.................................................................................................................................237
6.1.3 GSM CoRRM Report..............................................................................................................................................239
6.1.4 UMTS CoRRM Report............................................................................................................................................241
6.1.5 GSM Power Sharing Report....................................................................................................................................244
6.1.6 UMTS Power Sharing Report(RNC counter)..........................................................................................................245
6.1.7 UMTS Power sharing Report(NodeB counter).......................................................................................................246
6.1.8 Success Rate of Preparation for Outgoing Inter-RAT Inter-Cell Handover Analysis.............................................247
6.1.9 Success Rate of Preparation for Outgoing Inter-RAT Inter-Cell Radio Handover Analysis..................................252
6.1.10 Success Rate of Preparation for Incoming Inter-RAT Inter-Cell Handover Analysis..........................................255
6.1.11 Success Rate of Preparation for Incoming Inter-RAT Inter-Cell Radio Handover Analysis................................257
6.1.12 Success Rate of Preparations for CS Outgoing Inter-RAT Handover for Cell Analysis......................................258
6.1.13 Success Rate of CS Outgoing Inter-RAT Handovers for Cell Analysis...............................................................260
6.1.14 Success Rate of PS Outgoing Inter-RAT Handover Initiated by RNC for Cell Analysis.....................................261
6.1.15 Success Rate of Preparations for CS Incoming Inter-RAT Handovers for Cell Analysis.....................................262
6.1.16 Success Rate of CS Incoming Inter-RAT Handovers for Cell Analysis...............................................................264
6.2 GU Interoperations Report.........................................................................................................................................265
6.3 GU CoRRM Report....................................................................................................................................................269
6.4 GU Power Sharing Report..........................................................................................................................................274

7 WiMAX RAN Performance Report........................................................................................278


7.1 BTS performance Report............................................................................................................................................279
7.1.1 BS performance test Report.....................................................................................................................................279
7.2 Carrier Report.............................................................................................................................................................279
7.2.1 idle mode performance test Report..........................................................................................................................280
7.2.2 link quality performance test Report.......................................................................................................................281

Issue 01 (2015-05-30) Huawei Proprietary and Confidential v


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference Contents

7.2.3 handover performance test Report...........................................................................................................................283


7.2.4 network entry performance test Report...................................................................................................................285
7.2.5 network detach performance test Report.................................................................................................................288
7.2.6 throughput performance test Report........................................................................................................................289
7.2.7 carrier load performance test Report.......................................................................................................................290

8 CDMA BSS Performance Report............................................................................................293


8.1 CBSC-1x Performance Report...................................................................................................................................294
8.1.1 CBSC NE Report.....................................................................................................................................................294
8.1.2 CBSC Carrier Report...............................................................................................................................................310
8.2 CDMA BSS EV-DORB Performance Report............................................................................................................335
8.2.1 HRPD Session Report.............................................................................................................................................335
8.2.2 Cover Report............................................................................................................................................................361
8.2.3 Service Integrity Report...........................................................................................................................................368
8.2.4 Call Retainability Report.........................................................................................................................................381
8.2.5 Accessibility Report................................................................................................................................................389
8.2.6 Capacity Analysis Report........................................................................................................................................400
8.2.7 Network Coverage Analysis Report........................................................................................................................417
8.2.8 Mobility Report.......................................................................................................................................................428
8.2.9 Resource Utilization Analysis Report.....................................................................................................................447
8.3 CBSC-DO Performance Report..................................................................................................................................464
8.3.1 Service Integrality Report........................................................................................................................................464
8.3.2 Call Holding Report.................................................................................................................................................467
8.3.3 HRPD Session Report.............................................................................................................................................468
8.3.4 Accessablity Report.................................................................................................................................................487
8.3.5 Network Cover Report.............................................................................................................................................492
8.3.6 Network Capability Report......................................................................................................................................498
8.3.7 Mobility Report.......................................................................................................................................................506
8.3.8 Resource Usage Ratio Report..................................................................................................................................516
8.3.9 Cover Report............................................................................................................................................................519
8.3.10 Overview of Network Performance Report...........................................................................................................521

9 CHLR Performance Report......................................................................................................526


9.1 CHLR NE Report.......................................................................................................................................................527

10 CMSC Performance Report...................................................................................................528


10.1 CMSC NE Report.....................................................................................................................................................529

11 GGSN Performance Report...................................................................................................530


11.1 AAA performance Report........................................................................................................................................531
11.2 Session Service Report.............................................................................................................................................533
11.3 Data transfer Report..................................................................................................................................................534
11.4 System Resource Report...........................................................................................................................................536

12 HLR Performance Report.......................................................................................................537

Issue 01 (2015-05-30) Huawei Proprietary and Confidential vi


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference Contents

12.1 HLR NE Report........................................................................................................................................................538

13 eRAN Performance Report....................................................................................................539


13.1 LTE Reports.............................................................................................................................................................540
13.1.1 Accessibility Report..............................................................................................................................................540
13.1.2 Integrity Report......................................................................................................................................................541
13.1.3 LTE KPI Overview Report....................................................................................................................................543
13.1.4 Mobility Report.....................................................................................................................................................548
13.1.5 Retainability Report...............................................................................................................................................550
13.1.6 Traffic Report........................................................................................................................................................552
13.2 BTS Energy Consumption Report............................................................................................................................554
13.2.1 BTS Traffic and Energy Consumption Report......................................................................................................554
13.2.2 Network Energy Efficiency Indicator Report........................................................................................................555

14 MGW Performance Report....................................................................................................557


14.1 MGW NE Report......................................................................................................................................................558

15 MSCe Performance Report....................................................................................................560


15.1 System LoadSpecific KPI Report.............................................................................................................................561
15.1.1 Number of Subscribers Registered with the VLR Report.....................................................................................561
15.1.2 Processor Load Report...........................................................................................................................................561
15.1.3 Load over Signaling Links Report.........................................................................................................................562
15.1.4 Load over Trunk Circuits Report...........................................................................................................................563
15.2 Basic Telecom ServiceSpecific KPI Report.............................................................................................................564
15.3 ServiceSpecific KPI Report......................................................................................................................................566
15.4 Mobility ManagementSpecific KPI Report..............................................................................................................568

16 MSCServer Performance Report..........................................................................................572


16.1 Signalling Link Report.............................................................................................................................................573
16.1.1 BICC SCTP Link Report.......................................................................................................................................573
16.1.2 H248 SCTP Link Report.......................................................................................................................................574
16.1.3 M2UA Link Report...............................................................................................................................................576
16.1.4 M3UA Link Report...............................................................................................................................................577
16.1.5 MTP3B Link Report..............................................................................................................................................579
16.1.6 MTP3 Link Report.................................................................................................................................................581
16.2 CPU Load.................................................................................................................................................................582
16.3 Basic MSC Service Report.......................................................................................................................................583
16.4 Trunk Group Traffic.................................................................................................................................................588
16.5 Office Direction Traffic............................................................................................................................................591
16.6 Mobility Management Report..................................................................................................................................595

17 NodeB Performance Report...................................................................................................597


17.1 NodeB Report...........................................................................................................................................................598
17.2 BTS Energy Consumption Report............................................................................................................................598

Issue 01 (2015-05-30) Huawei Proprietary and Confidential vii


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference Contents

17.2.1 BTS Traffic and Energy Consumption Report......................................................................................................598


17.2.2 Network Energy Efficiency Indicator Report........................................................................................................600

18 PCU Performance Report.......................................................................................................603


18.1 Retainability Report..................................................................................................................................................604
18.2 Transmisson Report..................................................................................................................................................605
18.3 Accessability Report.................................................................................................................................................610
18.4 Data Throughput Report...........................................................................................................................................612
18.5 Availability Report...................................................................................................................................................616

19 UMTS RAN NHC Report.......................................................................................................619


19.1 Cell Performance Measurement(Morning Busy Time)............................................................................................620
19.2 Cell Performance Measurement(Night Busy Time).................................................................................................624
19.3 High Call Drop Rate Cell(Morning Busy Time)......................................................................................................628
19.4 High Call Drop Rate Cell(Night Busy Time)...........................................................................................................629
19.5 No Services Cell(Morning Busy Time)....................................................................................................................630
19.6 No Services Cell(Night Busy Time).........................................................................................................................631
19.7 Performance Check Gather Page..............................................................................................................................632
19.8 Traffic Volume Measurement..................................................................................................................................634
19.9 UL Interference Cell(Morning Busy Time)..............................................................................................................634
19.10 UL Interference Cell(Night Busy Time).................................................................................................................635
19.11 Unavailable Cell(Morning Busy Time)..................................................................................................................636
19.12 Unavailable Cell(Night Busy Time).......................................................................................................................637
19.13 Worst Cell(Morning Busy Time)...........................................................................................................................637
19.14 Worst Cell(Night Busy Time)................................................................................................................................639

20 UMTS RAN Performance Report.........................................................................................641


20.1 Cell Reports..............................................................................................................................................................642
20.1.1 Accessibility Report..............................................................................................................................................642
20.1.2 Mobility Report.....................................................................................................................................................648
20.1.3 Retainability Report...............................................................................................................................................650
20.1.4 Traffic Report........................................................................................................................................................651
20.2 Coverage Evaluation Reports...................................................................................................................................652
20.2.1 Cell Load Analysis Report....................................................................................................................................652
20.2.2 Coverage Evaluation Summary Report.................................................................................................................653
20.2.3 EcNo Analysis Report...........................................................................................................................................671
20.2.4 RSCP Analysis Report...........................................................................................................................................675
20.2.5 TP Analysis Report................................................................................................................................................679
20.2.6 UE TxPower Analysis Report...............................................................................................................................687
20.3 RNC Reports.............................................................................................................................................................689
20.3.1 Accessibility Report..............................................................................................................................................689
20.3.2 Coverage Report....................................................................................................................................................694
20.3.3 Mobility Report.....................................................................................................................................................695

Issue 01 (2015-05-30) Huawei Proprietary and Confidential viii


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference Contents

20.3.4 Retainability Report...............................................................................................................................................697


20.3.5 Traffic Report........................................................................................................................................................698
20.3.6 UMTS KPI Overview Report................................................................................................................................700
20.4 Troubleshooting Reports..........................................................................................................................................709
20.4.1 CS Call Drop Cells Report....................................................................................................................................709
20.4.2 CS RAB Fail Report..............................................................................................................................................711
20.4.3 PS Call Drop Cells Report.....................................................................................................................................713
20.4.4 PS RAB Fail Report..............................................................................................................................................716
20.4.5 RRC Fail Report....................................................................................................................................................718

21 UMTS RAN Professional Report......................................................................................... 721


21.1 Cluster Daily Report.................................................................................................................................................722
21.1.1 All Service KPI Report..........................................................................................................................................722
21.1.2 Call TopN Report..................................................................................................................................................732
21.1.3 HO TopN Report...................................................................................................................................................742
21.1.4 HSDPA KPI Report...............................................................................................................................................746
21.1.5 HSDPA TopN Report............................................................................................................................................750
21.1.6 HSUPA KPI Report...............................................................................................................................................752
21.1.7 Traffic TopN Report..............................................................................................................................................755
21.2 Cluster Weekly Report.............................................................................................................................................756
21.2.1 All Service KPI Report..........................................................................................................................................757
21.2.2 HSDPA KPI Report...............................................................................................................................................767
21.2.3 HSUPA KPI Report...............................................................................................................................................771
21.3 Monitoring Report....................................................................................................................................................773
21.3.1 Access TopN Report..............................................................................................................................................773
21.3.2 CDR TopN Report.................................................................................................................................................780
21.3.3 HO TopN Report...................................................................................................................................................784
21.3.4 RNC KPI Report....................................................................................................................................................789
21.3.5 Traffic TopN Report..............................................................................................................................................797
21.3.6 VIC KPI Report.....................................................................................................................................................808
21.4 Network shift Report................................................................................................................................................813
21.4.1 Call TopN Report..................................................................................................................................................814
21.4.2 Cluster KPI Report................................................................................................................................................822
21.4.3 HO TopN Report...................................................................................................................................................838
21.4.4 Hot Traffic Cell TopN Report...............................................................................................................................842
21.4.5 HSDPA TopN Report............................................................................................................................................849
21.4.6 Iur Performance TopN Report...............................................................................................................................852
21.4.7 KPI Report.............................................................................................................................................................854
21.5 RNC Daily Report....................................................................................................................................................869
21.5.1 Call TopN Report..................................................................................................................................................869
21.5.2 HO TopN Report...................................................................................................................................................879
21.5.3 Hot Traffic Cell TopN Report...............................................................................................................................883

Issue 01 (2015-05-30) Huawei Proprietary and Confidential ix


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference Contents

21.5.4 HSDPA KPI Daily Report.....................................................................................................................................889


21.5.5 HSDPA TopN Report............................................................................................................................................893
21.5.6 HSUPA KPI Daily Report.....................................................................................................................................895
21.5.7 HSUPA TopN Report............................................................................................................................................898
21.5.8 RNC All Service Daily Report..............................................................................................................................900
21.5.9 Traffic Cell TopN Report......................................................................................................................................911
21.5.10 Traffic RNC TopN Report...................................................................................................................................917
21.5.11 VIP Cell TopN Report.........................................................................................................................................918
21.6 RNC Monthly Report...............................................................................................................................................922
21.6.1 CDR Report...........................................................................................................................................................922
21.6.2 HO Report..............................................................................................................................................................925
21.6.3 HSDPA KPI Monthly Report................................................................................................................................927
21.6.4 HSUPA KPI Monthly Report................................................................................................................................931
21.6.5 PAGE Report.........................................................................................................................................................933
21.6.6 RAB Report...........................................................................................................................................................934
21.6.7 RCC Report...........................................................................................................................................................937
21.6.8 RNC All Service Monthly Report.........................................................................................................................943
21.6.9 Traffic Monthly BH Report...................................................................................................................................954
21.6.10 Traffic Report......................................................................................................................................................956
21.7 RNC Weekly Report.................................................................................................................................................957
21.7.1 CDR Report...........................................................................................................................................................958
21.7.2 HSDPA KPI Weekly Report.................................................................................................................................960
21.7.3 HSUPA KPI Weekly Report.................................................................................................................................963
21.7.4 Inter-RAT HO Report............................................................................................................................................966
21.7.5 PAGE Report.........................................................................................................................................................967
21.7.6 RAB Report...........................................................................................................................................................968
21.7.7 RNC All Service Weekly Report...........................................................................................................................971
21.7.8 RRC Report...........................................................................................................................................................982
21.7.9 Traffic Weekly BH Report....................................................................................................................................986
21.7.10 Traffic Weekly Report.........................................................................................................................................987

22 USN Performance Report.......................................................................................................989


22.1 Gb mode Report........................................................................................................................................................990
22.2 Iu mode Report.........................................................................................................................................................991
22.3 Link Report...............................................................................................................................................................992
22.4 Data transfer Report..................................................................................................................................................993

23 UGW Performance Report.....................................................................................................995


23.1 AAA performance Report........................................................................................................................................996
23.2 Session Service Report.............................................................................................................................................997
23.3 Data transfer Report..................................................................................................................................................998

24 SGSN Performance Report..................................................................................................1001

Issue 01 (2015-05-30) Huawei Proprietary and Confidential x


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference Contents

24.1 Gb mode Report......................................................................................................................................................1002


24.2 Iu mode Report.......................................................................................................................................................1003
24.3 Common Report.....................................................................................................................................................1005
24.4 Link Report.............................................................................................................................................................1006
24.5 Data transfer Report................................................................................................................................................1007

25 SG7000 Performance Report................................................................................................1009


25.1 SG7000 Performance Report_1..............................................................................................................................1010
25.1.1 DSP Report..........................................................................................................................................................1010
25.1.2 Link Report..........................................................................................................................................................1010
25.1.3 LinkSet Report.....................................................................................................................................................1012
25.1.4 M3UA ASSOAS Report......................................................................................................................................1012
25.1.5 M3UA Link Report.............................................................................................................................................1013
25.1.6 M3UA LinkSet Report........................................................................................................................................1014
25.1.7 SCCP globle Report.............................................................................................................................................1015
25.2 SG7000 Performance Report_2..............................................................................................................................1016
25.2.1 CPU Usage Report...............................................................................................................................................1016
25.2.2 DSP and Link Set Load Report...........................................................................................................................1017
25.2.3 DSP Report..........................................................................................................................................................1018
25.2.4 Link Load Busy Hour Report..............................................................................................................................1019
25.2.5 Link Load Report.................................................................................................................................................1020
25.2.6 Link Set Load Busy Hour Report........................................................................................................................1022
25.2.7 Link Set Load Report..........................................................................................................................................1022
25.2.8 Link Usage and Availability Report....................................................................................................................1023
25.2.9 M2PA Link Busy Hour Report............................................................................................................................1024
25.2.10 M2PA Link Report............................................................................................................................................1025
25.2.11 M3UA Link Busy Hour Report.........................................................................................................................1027
25.2.12 M3UA Link Report...........................................................................................................................................1028
25.2.13 Total Messages Requiring Global Title Translation Report..............................................................................1029

26 SPS Performance Report......................................................................................................1031


26.1 M3UA Link Report................................................................................................................................................1032
26.2 SCCP globle Report................................................................................................................................................1033
26.3 M3UA LinkSet Report...........................................................................................................................................1034
26.4 Link Report.............................................................................................................................................................1034
26.5 M3UA ASSOAS Report.........................................................................................................................................1036
26.6 LinkSet Report........................................................................................................................................................1037
26.7 DSP Report.............................................................................................................................................................1037

27 SPSV3 Performance Report.................................................................................................1039


27.1 CPU Usage Report..................................................................................................................................................1041
27.2 Diameter SCTP Send Load Busy Hour Report......................................................................................................1041
27.3 Number of Sent Diameter SCTP Data Chunks Busy Hour Report........................................................................1042

Issue 01 (2015-05-30) Huawei Proprietary and Confidential xi


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference Contents

27.4 Diameter SCTP Load Measurement Report...........................................................................................................1043


27.5 Diameter SCTP Load Measurement Busy Hour Report........................................................................................1044
27.6 Diameter SCTP Receive Load Busy Hour Report.................................................................................................1049
27.7 Number of Received Diameter SCTP Data Chunks Busy Hour Report................................................................1050
27.8 Diameter SCTP Bidirectional Load Busy Hour Report.........................................................................................1051
27.9 Diameter Interface Message Measurement Report.................................................................................................1052
27.10 Diameter Link Measurement Report....................................................................................................................1055
27.11 Diameter Message Measurement Report..............................................................................................................1057
27.12 Diameter Service Failure Measurement Report...................................................................................................1058
27.13 M2PA Link Load Report......................................................................................................................................1059
27.14 M2PA Link Load Busy Hour Report...................................................................................................................1061
27.15 M3UA Link Load Report.....................................................................................................................................1062
27.16 M3UA Link Load Busy Hour Report...................................................................................................................1064
27.17 STP Day Report....................................................................................................................................................1065
27.18 DSP Report...........................................................................................................................................................1075
27.19 Link Load Report..................................................................................................................................................1076
27.20 Link Load Busy Hour Report...............................................................................................................................1078
27.21 Linkset Load Report.............................................................................................................................................1079
27.22 Linkset Load Busy Hour Report...........................................................................................................................1080
27.23 Link Usage and Availability Report.....................................................................................................................1081
27.24 Total Messages Requiring Global Title Translation Report.................................................................................1082

28 VoLTE KPI Performance Report.........................................................................................1084


28.1 VoLTE KPI Report.................................................................................................................................................1085

29 2G Network Capacity Analysis Report.............................................................................1091


29.1 BSC.........................................................................................................................................................................1092
29.1.1 A Interface...........................................................................................................................................................1092
29.1.2 Ater Interface.......................................................................................................................................................1102
29.1.3 Board...................................................................................................................................................................1103
29.1.4 Gb........................................................................................................................................................................1118
29.2 BTS.........................................................................................................................................................................1119
29.2.1 Abis Interface(IP over E1)...................................................................................................................................1119
29.2.2 Abis Interface(IP over FE/GE)............................................................................................................................1121
29.2.3 Abis Interface(TDM)...........................................................................................................................................1123
29.3 Cell..........................................................................................................................................................................1124
29.3.1 Um(CS)................................................................................................................................................................1124
29.3.2 Um(PS)................................................................................................................................................................1126
29.4 EGPU/EXPU(CP Subsystem Detail Report)..........................................................................................................1129
29.5 EGPU/EXPU(CS UP Subsystem Detail Report)....................................................................................................1130
29.6 EGPU/EXPU(PS UP Subsystem Detail Report)....................................................................................................1130

30 3G Network Capacity Analysis Report.............................................................................1132

Issue 01 (2015-05-30) Huawei Proprietary and Confidential xii


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference Contents

30.1 Cell..........................................................................................................................................................................1133
30.1.1 Code.....................................................................................................................................................................1133
30.1.2 Common Channel................................................................................................................................................1135
30.1.3 Power...................................................................................................................................................................1138
30.1.4 UCell Traffic Model Report................................................................................................................................1141
30.1.5 UCell Traffic Trend Report.................................................................................................................................1143
30.2 NodeB..................................................................................................................................................................... 1144
30.2.1 CE........................................................................................................................................................................1144
30.2.2 CNBAP................................................................................................................................................................ 1145
30.2.3 HSPA User Number............................................................................................................................................1146
30.2.4 Iub........................................................................................................................................................................ 1147
30.2.5 NodeB Board.......................................................................................................................................................1156
30.2.6 NodeB License....................................................................................................................................................1156
30.2.7 NodeB Traffic Model Report..............................................................................................................................1157
30.2.8 NodeB Traffic Trend Report...............................................................................................................................1160
30.3 RNC........................................................................................................................................................................1161
30.3.1 Board...................................................................................................................................................................1161
30.3.2 Iu-CS....................................................................................................................................................................1172
30.3.3 Iu-PS....................................................................................................................................................................1178
30.3.4 Iur.........................................................................................................................................................................1184
30.3.5 License.................................................................................................................................................................1191
30.3.6 RNC Traffic Model Report(6910UMTS)............................................................................................................1202
30.3.7 RNC Traffic Model Report(6900UMTS)............................................................................................................1205
30.3.8 RNC Traffic Trend Report(6910UMTS).............................................................................................................1208
30.3.9 RNC Traffic Trend Report(6900UMTS).............................................................................................................1209
30.3.10 UCell Group Traffic Trend Report.................................................................................................................... 1210
30.4 DPU DSP Utilization Rate of one Physical Subrack..............................................................................................1211
30.5 DPU DSP Utilization Rate of RNC........................................................................................................................ 1212
30.6 EGPU(CP Subsystem Detail Report).....................................................................................................................1213
30.7 EGPU(UP Subsystem Detail Report).....................................................................................................................1214
30.8 EGPU CP Breakdown Report.................................................................................................................................1215
30.9 MPU CPU Utilization Rate of RNC.......................................................................................................................1218
30.10 Port traffic analysis............................................................................................................................................... 1219
30.11 RTWP Breakdown................................................................................................................................................1220
30.12 Breakdown Report................................................................................................................................................ 1221
30.13 SPU CPU Utilization Rate of RNC......................................................................................................................1225
30.14 TCP Breakdown...................................................................................................................................................1225

31 4G Network Capacity Analysis Report.............................................................................1228


31.1 eNodeB...................................................................................................................................................................1229
31.1.1 Board...................................................................................................................................................................1229
31.1.2 eNodeB License...................................................................................................................................................1231

Issue 01 (2015-05-30) Huawei Proprietary and Confidential xiii


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference Contents

31.1.3 RscGroup.............................................................................................................................................................1232
31.1.4 eNodeB Traffic Model Report.............................................................................................................................1234
31.1.5 eNodeB Traffic Trend Report..............................................................................................................................1238
31.2 LTE Cell.................................................................................................................................................................1239
31.2.1 Channel................................................................................................................................................................1239
31.2.2 PRB Rsc...............................................................................................................................................................1243
31.2.3 VoIP.....................................................................................................................................................................1246
31.2.4 LTE Cell Traffic Model Report...........................................................................................................................1248
31.2.5 LTE Cell Traffic Trend Report............................................................................................................................1252
31.3 LTE Cell Group Traffic Trend Report....................................................................................................................1254

Issue 01 (2015-05-30) Huawei Proprietary and Confidential xiv


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 1 ASNGW Performance Report

1 ASNGW Performance Report

About This Chapter

1.1 ASNGW NE Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 1 ASNGW Performance Report

1.1 ASNGW NE Report


Report Type
Simple Report

NE Type
ASNGW

Object Type
ASNGW

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

ASNGW Number of Received numb PPPC -


PPP Negotiation er Performance
Packets Measuremen
t
(WASN9770
)

Number of Sent PPP numb PPPC -


Negotiation Packets er Performance
Measuremen
t
(WASN9770
)

Number of Received numb PPPC -


Invalid PPP er Performance
Negotiation Packets Measuremen
t
(WASN9770
)

Number of times PPPC -


Successful LCP Performance
Negotiations Measuremen
t
(WASN9770
)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 2


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 1 ASNGW Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Number of LCP times PPPC -


Negotiation Performance
Attempts Measuremen
t
(WASN9770
)

Number of times PPPC -


Successful IPCP Performance
Negotiations Measuremen
t
(WASN9770
)

Number of IPCP times PPPC -


Negotiation Performance
Attempts Measuremen
t
(WASN9770
)

Number of times PPPC -


Successful CCP Performance
Negotiations Measuremen
t
(WASN9770
)

Number of CCP times PPPC -


Negotiation Performance
Attempts Measuremen
t
(WASN9770
)

Number of Received numb PPPC -


Stac LZS er Performance
Compressed Packets Measuremen
t
(WASN9770
)

Number of Sent Stac numb PPPC -


LZS Compressed er Performance
Packets Measuremen
t
(WASN9770
)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 3


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 1 ASNGW Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Number of Received numb PPPC -


Microsoft Point-to- er Performance
Point Compressed Measuremen
Packets t
(WASN9770
)

Number of Sent numb PPPC -


Microsoft Point-to- er Performance
Point Compressed Measuremen
Packets t
(WASN9770
)

Number of times PPPC -


Successful PPP Performance
Negotiations Measuremen
t
(WASN9770
)

Number of PPP times PPPC -


Negotiation Performance
Attempts Measuremen
t
(WASN9770
)

Number of Received numb L2TP -


L2TP Control er Performance
Packets Measuremen
t
(WASN9770
)

Number of Received numb L2TP -


Invalid L2TP Control er Performance
Packets Measuremen
t
(WASN9770
)

Number of Sent numb L2TP -


L2TP Control er Performance
Packets Measuremen
t
(WASN9770
)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 4


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 1 ASNGW Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Number of L2TP times L2TP -


Tunnel Setup Performance
Attempts Measuremen
t
(WASN9770
)

Number of times L2TP -


Successful L2TP Performance
Tunnel Setup Times Measuremen
t
(WASN9770
)

Number of L2TP times L2TP -


Session Setup Performance
Attempts Measuremen
t
(WASN9770
)

Number of times L2TP -


Successful L2TP Performance
Session Setup Times Measuremen
t
(WASN9770
)

Success Rate for % Data Plane -


Uplink Packet Based
Forwarding Forwarding
(WASN9770) Performance
Measuremen
t
(WASN9770
)

Success Rate for % Data Plane -


Downlink Packet Based
Forwarding Forwarding
(WASN9770) Performance
Measuremen
t
(WASN9770
)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 5


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 1 ASNGW Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Number of Uplink packe Data Plane -


Packets on the R3 t Based
Interface Forwarding
(WASN9770) Performance
Measuremen
t
(WASN9770
)

Number of Downlink packe Data Plane -


Packets on the R3 t Based
Interface Forwarding
(WASN9770) Performance
Measuremen
t
(WASN9770
)

Number of Error packe Data Plane -


Downlink Packets on t Based
the R3 Interface Forwarding
(WASN9770) Performance
Measuremen
t
(WASN9770
)

Average Packet packe Data Plane -


Throughput on the ts/ Based
R3 Interface secon Forwarding
(WASN9770) d Performance
Measuremen
t
(WASN9770
)

Maximum Packet packe Data Plane -


Throughput on the ts/ Based
R3 Interface secon Forwarding
(WASN9770) d Performance
Measuremen
t
(WASN9770
)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 6


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 1 ASNGW Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Average Uplink packe Data Plane -


Packet Rate on the ts/ Based
R3 Interface secon Forwarding
(WASN9770) d Performance
Measuremen
t
(WASN9770
)

Maximum Uplink packe Data Plane -


Packet Rate on the ts/ Based
R3 Interface secon Forwarding
(WASN9770) d Performance
Measuremen
t
(WASN9770
)

Average Downlink packe Data Plane -


Packet Rate on the ts/ Based
R3 Interface secon Forwarding
(WASN9770) d Performance
Measuremen
t
(WASN9770
)

Maximum Downlink packe Data Plane -


Packet Rate on the ts/ Based
R3 Interface secon Forwarding
(WASN9770) d Performance
Measuremen
t
(WASN9770
)

Number of Uplink packe Data Plane -


Packets on R4 and R6 t Based
Interfaces Forwarding
(WASN9770) Performance
Measuremen
t
(WASN9770
)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 7


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 1 ASNGW Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Number of Downlink packe Data Plane -


Packets on R4 and R6 t Based
Interfaces Forwarding
(WASN9770) Performance
Measuremen
t
(WASN9770
)

Number of Error packe Data Plane -


Uplink Packets on R4 t Based
and R6 Forwarding
(WASN9770) Performance
Measuremen
t
(WASN9770
)

Average Packet packe Data Plane -


Throughput on R4 ts/ Based
and R6 Interfaces secon Forwarding
(WASN9770) d Performance
Measuremen
t
(WASN9770
)

Maximum Packet packe Data Plane -


Throughput on R4 ts/ Based
and R6 Interfaces secon Forwarding
(WASN9770) d Performance
Measuremen
t
(WASN9770
)

Average Uplink packe Data Plane -


Packet Rate on R4 ts/ Based
and R6 Interfaces secon Forwarding
(WASN9770) d Performance
Measuremen
t
(WASN9770
)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 8


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 1 ASNGW Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Maximum Uplink packe Data Plane -


Packet Rate on R4 ts/ Based
and R6 Interfaces secon Forwarding
(WASN9770) d Performance
Measuremen
t
(WASN9770
)

Average Downlink packe Data Plane -


Packet Rate on R4 ts/ Based
and R6 Interfaces secon Forwarding
(WASN9770) d Performance
Measuremen
t
(WASN9770
)

Maximum Downlink packe Data Plane -


Packet Rate on R4 ts/ Based
and R6 Interfaces secon Forwarding
(WASN9770) d Performance
Measuremen
t
(WASN9770
)

Uplink Packets packe Data Plane -


Exceeding 1500 t Based
Bytes on R4 and R6 Forwarding
(WASN9770) Performance
Measuremen
t
(WASN9770
)

Downlink Packets packe Data Plane -


Exceeding 1500 t Based
Bytes on R3 Forwarding
(WASN9770) Performance
Measuremen
t
(WASN9770
)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 9


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 1 ASNGW Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Uplink Traffic on the kiloby Data Plane -


R3 Interface (KB) tes Based
(WASN9770) Forwarding
Performance
Measuremen
t
(WASN9770
)

Downlink Traffic on kiloby Data Plane -


the R3 Interface (KB) tes Based
(WASN9770) Forwarding
Performance
Measuremen
t
(WASN9770
)

Uplink Traffic on the MB Data Plane -


R3 Interface (MB) Based
(WASN9770) Forwarding
Performance
Measuremen
t
(WASN9770
)

Downlink Traffic on MB Data Plane -


the R3 Interface Based
(MB) (WASN9770) Forwarding
Performance
Measuremen
t
(WASN9770
)

Average Throughput kiloby Data Plane -


on the R3 Interface tes/ Based
(KB/s) secon Forwarding
(WASN9770) d Performance
Measuremen
t
(WASN9770
)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 10


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 1 ASNGW Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Maximum kiloby Data Plane -


Throughput on the tes/ Based
R3 Interface (KB/s) secon Forwarding
(WASN9770) d Performance
Measuremen
t
(WASN9770
)

Average Throughput mb/ Data Plane -


on the R3 Interface secon Based
(MB/s) d Forwarding
(WASN9770) Performance
Measuremen
t
(WASN9770
)

Maximum mb/ Data Plane -


Throughput on the secon Based
R3 Interface (MB/s) d Forwarding
(WASN9770) Performance
Measuremen
t
(WASN9770
)

Average Uplink Rate kiloby Data Plane -


on the R3 Interface tes/ Based
(KB/s) secon Forwarding
(WASN9770) d Performance
Measuremen
t
(WASN9770
)

Maximum Uplink kiloby Data Plane -


Rate on the R3 tes/ Based
Interface (KB/s) secon Forwarding
(WASN9770) d Performance
Measuremen
t
(WASN9770
)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 11


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 1 ASNGW Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Average Downlink kiloby Data Plane -


Rate on the R3 tes/ Based
Interface (KB/s) secon Forwarding
(WASN9770) d Performance
Measuremen
t
(WASN9770
)

Maximum Downlink kiloby Data Plane -


Rate on the R3 tes/ Based
Interface (KB/s) secon Forwarding
(WASN9770) d Performance
Measuremen
t
(WASN9770
)

Uplink Traffic on R4 kiloby Data Plane -


and R6 Interfaces tes Based
(KB) (WASN9770) Forwarding
Performance
Measuremen
t
(WASN9770
)

Downlink Traffic on kiloby Data Plane -


R4 and R6 Interfaces tes Based
(KB) (WASN9770) Forwarding
Performance
Measuremen
t
(WASN9770
)

Uplink Traffic on R4 MB Data Plane -


and R6 Interfaces Based
(MB) (WASN9770) Forwarding
Performance
Measuremen
t
(WASN9770
)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 12


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 1 ASNGW Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Downlink Traffic on MB Data Plane -


R4 and R6 Interfaces Based
(MB) (WASN9770) Forwarding
Performance
Measuremen
t
(WASN9770
)

Average Throughput kiloby Data Plane -


on R4 and R6 tes/ Based
Interfaces (KB/s) secon Forwarding
(WASN9770) d Performance
Measuremen
t
(WASN9770
)

Maximum kiloby Data Plane -


Throughput on R4 tes/ Based
and R6 Interfaces secon Forwarding
(KB/s) d Performance
(WASN9770) Measuremen
t
(WASN9770
)

Average Throughput mb/ Data Plane -


on R4 and R6 secon Based
Interfaces (MB/s) d Forwarding
(WASN9770) Performance
Measuremen
t
(WASN9770
)

Maximum mb/ Data Plane -


Throughput on R4 secon Based
and R6 Interfaces d Forwarding
(MB/s) Performance
(WASN9770) Measuremen
t
(WASN9770
)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 13


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 1 ASNGW Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Average Uplink Rate kiloby Data Plane -


on R4 and R6 tes/ Based
Interfaces (KB/s) secon Forwarding
(WASN9770) d Performance
Measuremen
t
(WASN9770
)

Maximum Uplink kiloby Data Plane -


Rate on R4 and R6 tes/ Based
Interfaces (KB/s) secon Forwarding
(WASN9770) d Performance
Measuremen
t
(WASN9770
)

Average Downlink kiloby Data Plane -


Rate on R4 and R6 tes/ Based
Interfaces (KB/s) secon Forwarding
(WASN9770) d Performance
Measuremen
t
(WASN9770
)

Maximum Downlink kiloby Data Plane -


Rate on R4 and R6 tes/ Based
Interfaces (KB/s) secon Forwarding
(WASN9770) d Performance
Measuremen
t
(WASN9770
)

Number of Received packe Authenticati -


EAP-Start Messages t on
(WASN9770) Performance
Measuremen
t
(WASN9770
)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 14


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 1 ASNGW Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Number of EAP- packe Authenticati -


Request Messages t on
Sent to the BS Performance
(WASN9770) Measuremen
t
(WASN9770
)

Number of EAP- packe Authenticati -


Response Messages t on
Received from the Performance
BS (WASN9770) Measuremen
t
(WASN9770
)

Number of times Authenticati -


Successful on
Authentication Performance
Responses Measuremen
(WASN9770) t
(WASN9770
)

Number of times Authenticati -


Authentication on
Requests Performance
(WASN9770) Measuremen
t
(WASN9770
)

Number of Re-sent times Authenticati -


Authentication on
Requests Performance
(WASN9770) Measuremen
t
(WASN9770
)

Number of EAP- numb Authenticati -


Response Messages er on
to the AAA Server Performance
(WASN9770) Measuremen
t
(WASN9770
)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 15


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 1 ASNGW Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Number of EAP- numb Authenticati -


Request Messages er on
from the AAA Server Performance
(WASN9770) Measuremen
t
(WASN9770
)

Number of EAP- numb Authenticati -


Success Messages er on
from the AAA Server Performance
(WASN9770) Measuremen
t
(WASN9770
)

Number of EAP- numb Authenticati -


Failure Messages er on
from the AAA Server Performance
(WASN9770) Measuremen
t
(WASN9770
)

Number of times Accounting -


Successful and UDR
Accounting Start Performance
Responses Measuremen
(WASN9770) t
(WASN9770
)

Number of times Accounting -


Accounting Start and UDR
Requests Performance
(WASN9770) Measuremen
t
(WASN9770
)

Number of Re-sent times Accounting -


Accounting Start and UDR
Requests Performance
(WASN9770) Measuremen
t
(WASN9770
)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 16


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 1 ASNGW Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Number of times Accounting -


Successful Interim- and UDR
UDR Updates Performance
(WASN9770) Measuremen
t
(WASN9770
)

Number of Interim- times Accounting -


UDR Update and UDR
Requests Performance
(WASN9770) Measuremen
t
(WASN9770
)

Number of Re-sent times Accounting -


Interim-UDR Update and UDR
Requests Performance
(WASN9770) Measuremen
t
(WASN9770
)

Number of times Accounting -


Successful and UDR
Accounting End Performance
Responses Measuremen
(WASN9770) t
(WASN9770
)

Number of numb Accounting -


Accounting End er and UDR
Requests Performance
(WASN9770) Measuremen
t
(WASN9770
)

Number of Re-sent numb Accounting -


Accounting End er and UDR
Requests Performance
(WASN9770) Measuremen
t
(WASN9770
)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 17


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 1 ASNGW Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Number of Sent times Accounting -


Messages Carrying and UDR
UDRs (WASN9770) Performance
Measuremen
t
(WASN9770
)

Number of times Accounting -


Successfully Sent and UDR
Messages Carrying Performance
UDRs (WASN9770) Measuremen
t
(WASN9770
)

Number of UDRs numb Accounting -


Waiting to Be Sent er and UDR
(WASN9770) Performance
Measuremen
t
(WASN9770
)

Number of Received times AAA -


Invalid AAA Performance
Messages Measuremen
(WASN9770) t
(WASN9770
)

Number of AAA times AAA -


Link Interruption Performance
Times (WASN9770) Measuremen
t
(WASN9770
)

Number of Activated numb Session -


Service Flows er Performance
(WASN9770) Measuremen
t
(WASN9770
)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 18


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 1 ASNGW Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Average Number of numb Session -


Activated Service er Performance
Flows (WASN9770) Measuremen
t
(WASN9770
)

Maximum Number numb Session -


of Activated Service er Performance
Flows (WASN9770) Measuremen
t
(WASN9770
)

Number of UGS numb Session -


Service Flows er Performance
(WASN9770) Measuremen
t
(WASN9770
)

Number of ertPS numb Session -


Service Flows er Performance
(WASN9770) Measuremen
t
(WASN9770
)

Number of rtPS numb Session -


Service Flows er Performance
(WASN9770) Measuremen
t
(WASN9770
)

Number of nrtPS numb Session -


Service Flows er Performance
(WASN9770) Measuremen
t
(WASN9770
)

Number of BE numb Session -


Service Flows er Performance
(WASN9770) Measuremen
t
(WASN9770
)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 19


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 1 ASNGW Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Number of Users numb Session -


with Dynamic IP er Performance
Addresses Measuremen
(WASN9770) t
(WASN9770
)

Number of Users numb Session -


with Static IP er Performance
Addresses Measuremen
(WASN9770) t
(WASN9770
)

Number of DP times Session -


Registration Performance
Requests Measuremen
(WASN9770) t
(WASN9770
)

Number of times Session -


Successful DP Performance
Registration Times Measuremen
(WASN9770) t
(WASN9770
)

Number of Re-sent times Session -


DP Registration Performance
Requests Measuremen
(WASN9770) t
(WASN9770
)

Number of DP times Session -


Deregistration Performance
Requests Measuremen
(WASN9770) t
(WASN9770
)

Number of times Session -


Successful DP Performance
Deregistration Times Measuremen
(WASN9770) t
(WASN9770
)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 20


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 1 ASNGW Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Number of Re-sent times Session -


DP Deregistration Performance
Requests Measuremen
(WASN9770) t
(WASN9770
)

Total Online numb Session -


Duration of Users er Performance
(WASN9770) Measuremen
t
(WASN9770
)

Average Online numb Session -


Duration of Users er Performance
(WASN9770) Measuremen
t
(WASN9770
)

Number of Activated numb Session -


Users (WASN9770) er Performance
Measuremen
t
(WASN9770
)

Number of Access numb Network -


Users (WASN9770) er Access
Performance
Measuremen
t
(WASN9770
)

Average Number of numb Network -


Access Users er Access
(WASN9770) Performance
Measuremen
t
(WASN9770
)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 21


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 1 ASNGW Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Maximum Number numb Network -


of Access Users er Access
(WASN9770) Performance
Measuremen
t
(WASN9770
)

Number of numb Network -


Registration Updates er Access
(WASN9770) Performance
Measuremen
t
(WASN9770
)

Number of Network times Network -


Access Requests Access
(WASN9770) Performance
Measuremen
t
(WASN9770
)

Number of times Network -


Successful Network Access
Access Times Performance
(WASN9770) Measuremen
t
(WASN9770
)

Success Rate of % Network -


Network Access Access
(WASN9770) Performance
Measuremen
t
(WASN9770
)

Access Failure Due times Network -


to AUTC Access
Negotiation Failure Performance
(WASN9770) Measuremen
t
(WASN9770
)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 22


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 1 ASNGW Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Access Failure Due times Network -


to Capability Access
Negotiation Failure Performance
(WASN9770) Measuremen
t
(WASN9770
)

Access Failure Due times Network -


to Other Reason Access
(WASN9770) Performance
Measuremen
t
(WASN9770
)

Number of Access times Network -


Authentication Access
Negotiation Performance
Requests Measuremen
(WASN9770) t
(WASN9770
)

Number of Access times Network -


Authentication Access
Negotiation Performance
Responses Measuremen
(WASN9770) t
(WASN9770
)

Number of Access times Network -


Capability Access
Negotiation Performance
Requests Measuremen
(WASN9770) t
(WASN9770
)

Number of Access times Network -


Capability Access
Negotiation Performance
Responses Measuremen
(WASN9770) t
(WASN9770
)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 23


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 1 ASNGW Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Number of Sent times Network -


Access Negotiation Access
Responses Performance
(WASN9770) Measuremen
t
(WASN9770
)

Number of MIP numb Network -


Users(WASN9770) er Access
Performance
Measuremen
t
(WASN9770
)

Number of PPPoE numb Network -


Users(WASN9770) er Access
Performance
Measuremen
t
(WASN9770
)

Number of L2TP numb Network -


Users(WASN9770) er Access
Performance
Measuremen
t
(WASN9770
)

Expiration of BS times Radio -


Neighbor Parameter Resource
Synchronization Measuremen
(WASN9770) t
(WASN9770
)

Success of Neighbor times Radio -


Parameter Resource
Synchronization of Measuremen
BS (WASN9770) t
(WASN9770
)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 24


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 1 ASNGW Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Success of Spare times Radio -


Capacity Reporting Resource
of BS (WASN9770) Measuremen
t
(WASN9770
)

Expiration of Spare times Radio -


Capacity Reporting Resource
of BS (Board) Measuremen
t
(WASN9770
)

Number of Idle Users numb Radio -


(WASN9770) er Resource
Measuremen
t
(WASN9770
)

Number of Paging times Radio -


Initiation Times Resource
(WASN9770) Measuremen
t
(WASN9770
)

Number of times Radio -


Successful Paging Resource
Times (WASN9770) Measuremen
t
(WASN9770
)

Number of Re-sent times Radio -


Paging Initiation Resource
Times (WASN9770) Measuremen
t
(WASN9770
)

Number of Paging times Radio -


Failure Times Due to Resource
No Response Measuremen
(WASN9770) t
(WASN9770
)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 25


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 1 ASNGW Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Paging Failure Due times Radio -


to Failure to Get Resource
Target BS Info Measuremen
(WASN9770) t
(WASN9770
)

Number of Paging times Radio -


Failure Times Due to Resource
Other Reason Measuremen
(WASN9770) t
(WASN9770
)

Number of Location times Radio -


Update Requests Resource
(WASN9770) Measuremen
t
(WASN9770
)

Number of Location times Radio -


Update Responses Resource
(WASN9770) Measuremen
t
(WASN9770
)

Number of Failed times Radio -


Location Updates Resource
Due to No Response Measuremen
(WASN9770) t
(WASN9770
)

Number of Failed times Radio -


Location Updates Resource
Due to Rejection Measuremen
(WASN9770) t
(WASN9770
)

Number of Failed times Radio -


Location Updates Resource
Due to Other Reason Measuremen
(WASN9770) t
(WASN9770
)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 26


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 1 ASNGW Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Number of Requests times Radio -


for Entering Idle Resource
State (WASN9770) Measuremen
t
(WASN9770
)

Number of Times for times Radio -


Successfully Resource
Entering Idle State Measuremen
(WASN9770) t
(WASN9770
)

Number of Failed times Radio -


Idle-State Entry Resource
Times (Rejected) Measuremen
(WASN9770) t
(WASN9770
)

Number of Failed times Radio -


Idle-State Entry Resource
Times (Other Measuremen
Reason) t
(WASN9770) (WASN9770
)

Number of Requests times Radio -


for Exiting from Idle Resource
State (WASN9770) Measuremen
t
(WASN9770
)

Number of Times for times Radio -


Successful Idle-State Resource
Exit (WASN9770) Measuremen
t
(WASN9770
)

Number of Failed times Radio -


Idle-State Exit Times Resource
(Rejected) Measuremen
(WASN9770) t
(WASN9770
)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 27


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 1 ASNGW Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Number of Failed times Radio -


Idle-State Exit Times Resource
(Other Reason) Measuremen
(WASN9770) t
(WASN9770
)

Radio Resource times Radio -


Configuration Resource
Update Requests Measuremen
(WASN9770) t
(WASN9770
)

Radio Resource times Radio -


Configuration Resource
Update Request Measuremen
Success t
(WASN9770) (WASN9770
)

Radio Resource times Radio -


Configuration Resource
Update Request Measuremen
Failure t
(WASN9770) (WASN9770
)

Number of Received times Radio -


Relay Messages Resource
(WASN9770) Measuremen
t
(WASN9770
)

Number of times Radio -


Successfully Relayed Resource
Messages Measuremen
(WASN9770) t
(WASN9770
)

Number of Failures times Radio -


to Relay Messages Resource
Due to No Next Hop Measuremen
(WASN9770) t
(WASN9770
)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 28


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 1 ASNGW Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Number of Failures times Radio -


to Relay Messages Resource
Due to R4 Loop Measuremen
(WASN9770) t
(WASN9770
)

Failure to Relay times Radio -


Messages Due to Resource
Mobile Forbidden Measuremen
(WASN9770) t
(WASN9770
)

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 29


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 2 BSC32 NHC Report

2 BSC32 NHC Report

About This Chapter

2.1 High Call Drop Rate Cell(Night Busy Time)

2.2 High Call Drop Rate Cell(Morning Busy Time)

2.3 High Congestion Rate Cell(Night Busy Time)

2.4 High Congestion Rate Cell(Morning Busy Time)

2.5 Traffic Volume Measurement

2.6 Cell Performance Measurement(Night Busy Time)

2.7 Cell Performance Measurement(Morning Busy Time)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 30


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 2 BSC32 NHC Report

2.1 High Call Drop Rate Cell(Night Busy Time)


Report Type
Simple Report

NE Type
BSC

Object Type
Cell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

High Call TCH Availablity(%) % Other [Available TCHs]/


Drop Measuremen ([Configured TCHs of
Rate Cell t Function 1800/1900 cell]+[Configured
TCHs of 900/850 cell])*{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

2.2 High Call Drop Rate Cell(Morning Busy Time)


Report Type
Simple Report

NE Type
BSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 31


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 2 BSC32 NHC Report

Object Type
Cell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

High Call TCH Availablity(%) % Other [Available TCHs]/


Drop Measuremen ([Configured TCHs of
Rate Cell t Function 1800/1900 cell]+[Configured
TCHs of 900/850 cell])*{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

2.3 High Congestion Rate Cell(Night Busy Time)


Report Type
Simple Report

NE Type
BSC

Object Type
Cell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

High TCH Congestion % TCH [Attempted TCH seizures


Congesti Rate Measuremen meeting TCH overflow]/
on Rate t Function [Attempted TCH seizures (all)]
Cell *{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 32


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 2 BSC32 NHC Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

2.4 High Congestion Rate Cell(Morning Busy Time)


Report Type
Simple Report

NE Type
BSC

Object Type
Cell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

High TCH Congestion % TCH [Attempted TCH seizures


Congesti Rate Measuremen meeting TCH overflow]/
on Rate t Function [Attempted TCH seizures (all)]
Cell *{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 33


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 2 BSC32 NHC Report

2.5 Traffic Volume Measurement


Report Type
Simple Report

NE Type
BSC

Object Type
BSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Traffic TCH Traffic % Access [Sum of CM service rejections]


Volume Measuremen
Measure t Function
ment

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

2.6 Cell Performance Measurement(Night Busy Time)


Report Type
Simple Report

NE Type
BSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 34


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 2 BSC32 NHC Report

Object Type
Cell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Cell TCH Traffic % Access [Sum of CM service rejections]


Performa Measuremen
nce t Function
Measure
ment TCH Congestion % TCH [Attempted TCH seizures
Rate Measuremen meeting TCH overflow]/
t Function [Attempted TCH seizures (all)]
*{100}

TCH Availablity(%) % Other [Available TCHs]/


Measuremen ([Configured TCHs of
t Function 1800/1900 cell]+[Configured
TCHs of 900/850 cell])*{100}

TCH Drop Rate(with % TCH ([TCH call drop]+[TCH drop


HO) Measuremen for very early assignment])/
t Function [Successful TCH seizures (all)]
*{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

2.7 Cell Performance Measurement(Morning Busy Time)


Report Type
Simple Report

NE Type
BSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 35


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 2 BSC32 NHC Report

Object Type
Cell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Cell TCH Traffic % Access [Sum of CM service rejections]


Performa Measuremen
nce t Function
Measure
ment TCH Congestion % TCH [Attempted TCH seizures
Rate Measuremen meeting TCH overflow]/
t Function [Attempted TCH seizures (all)]
*{100}

TCH Availablity(%) % Other [Available TCHs]/


Measuremen ([Configured TCHs of
t Function 1800/1900 cell]+[Configured
TCHs of 900/850 cell])*{100}

TCH Drop Rate(with % TCH ([TCH call drop]+[TCH drop


HO) Measuremen for very early assignment])/
t Function [Successful TCH seizures (all)]
*{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 36


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

3 BSC32 Performance Report

About This Chapter

3.1 BSC KPI Report

3.2 Special Cell Report

3.3 Cell KPI Report

3.4 Cell TopN Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 37


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

3.1 BSC KPI Report

3.1.1 Retainability Report

Report Type
Simple Report

NE Type
BSC

Object Type
BSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Retainabi TCH Call Drop Rate % TCH ([TCH call drop]+[TCH drop
lity (including Measuremen for very early assignment])/
handovers)(%) t Function [Successful TCH seizures (all)]
*{100}

TCH Call Drop Rate % TCH [TCH call drop]/([Successful


(excluding Measuremen TCH seizures for call]+
handovers)(%) t Function [Successful TCH allocation for
very early assignment])*{100}

SDCCH Drop Rate % SDCCH ([SDCCH call drop]/


(%) Measuremen [Successful SDCCH seizures
t Function (all)])*{100}

TCH Drop Rate Due % TCH ([TCH lost radio connections


to Radio Link Failure Measuremen (connection failure)]+[TCH
According to all TCH t Function lost radio connections (error
Drop(%) indication)])/[Successful TCH
seizures (all)]*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 38


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

TCH Drop Rate Due % Other (([Unsuccessful internal inter


to Handover Failure Measuremen cell handovers with
(%) t Function unsuccessful reversions]+
[Unsuccessful intracell
handovers with unsuccessful
reversions]+[Unsuccessful
outgoing BSC handovers with
unsuccessful reversion])/
[Successful TCH seizures
(all)])*{100}

Rate of Traffic none TCH ([Sum of TCH measurements


Volume to Call Measuremen in the cell (excluding very early
Drops t Function assignment)]*{48}/({100}*
{GP}*{60}))*{60}/[TCH call
drop]

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

3.1.2 Service Quality Report

Report Type
Simple Report

NE Type
BSC

Object Type
BSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 39


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Service TCH Uplink Quality % Full Rate ((([Uplink receiving level rank
Quality Identifier(%) Receiving 0 and receiving quality rank 0
Level in Full Rate TCH]+[Uplink
Measuremen receiving level rank 1 and
t Function receiving quality rank 0 in Full
Rate TCH]+[Uplink receiving
level rank 2 and receiving
quality rank 0 in Full Rate
TCH]+[Uplink receiving level
rank 3 and receiving quality
rank 0 in Full Rate TCH]+
[Uplink receiving level rank 4
and receiving quality rank 0 in
Full Rate TCH]+[Uplink
receiving level rank 5 and
receiving quality rank 0 in Full
Rate TCH]+[Uplink receiving
level rank 0 and receiving
quality rank 1 in Full Rate
TCH]+[Uplink receiving level
rank 1 and receiving quality
rank 1 in Full Rate TCH]+
[Uplink receiving level rank 2
and receiving quality rank 1 in
Full Rate TCH]+[Uplink
receiving level rank 3 and
receiving quality rank 1 in Full
Rate TCH]+[Uplink receiving
level rank 4 and receiving
quality rank 1 in Full Rate
TCH]+[Uplink receiving level
rank 5 and receiving quality
rank 1 in Full Rate TCH]))+
(([Uplink receiving level rank 0
and receiving quality rank 2 in
Full Rate TCH]+[Uplink
receiving level rank 1 and
receiving quality rank 2 in Full
Rate TCH]+[Uplink receiving
level rank 2 and receiving
quality rank 2 in Full Rate
TCH]+[Uplink receiving level
rank 3 and receiving quality
rank 2 in Full Rate TCH]+
[Uplink receiving level rank 4

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 40


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

and receiving quality rank 2 in


Full Rate TCH]+[Uplink
receiving level rank 5 and
receiving quality rank 2 in Full
Rate TCH]+[Uplink receiving
level rank 0 and receiving
quality rank 3 in Full Rate
TCH]+[Uplink receiving level
rank 1 and receiving quality
rank 3 in Full Rate TCH]+
[Uplink receiving level rank 2
and receiving quality rank 3 in
Full Rate TCH]+[Uplink
receiving level rank 3 and
receiving quality rank 3 in Full
Rate TCH]+[Uplink receiving
level rank 4 and receiving
quality rank 3 in Full Rate
TCH]+[Uplink receiving level
rank 5 and receiving quality
rank 3 in Full Rate TCH])))/
((([Uplink receiving level rank
0 and receiving quality rank 4
in Full Rate TCH]+[Uplink
receiving level rank 1 and
receiving quality rank 4 in Full
Rate TCH]+[Uplink receiving
level rank 2 and receiving
quality rank 4 in Full Rate
TCH]+[Uplink receiving level
rank 3 and receiving quality
rank 4 in Full Rate TCH]+
[Uplink receiving level rank 4
and receiving quality rank 4 in
Full Rate TCH]+[Uplink
receiving level rank 5 and
receiving quality rank 4 in Full
Rate TCH]+[Uplink receiving
level rank 0 and receiving
quality rank 5 in Full Rate
TCH]+[Uplink receiving level
rank 1 and receiving quality
rank 5 in Full Rate TCH]+
[Uplink receiving level rank 2
and receiving quality rank 5 in
Full Rate TCH]+[Uplink
receiving level rank 3 and

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 41


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

receiving quality rank 5 in Full


Rate TCH]+[Uplink receiving
level rank 4 and receiving
quality rank 5 in Full Rate
TCH]+[Uplink receiving level
rank 5 and receiving quality
rank 5 in Full Rate TCH]))+
(([Uplink receiving level rank 0
and receiving quality rank 6 in
Full Rate TCH]+[Uplink
receiving level rank 1 and
receiving quality rank 6 in Full
Rate TCH]+[Uplink receiving
level rank 2 and receiving
quality rank 6 in Full Rate
TCH]+[Uplink receiving level
rank 3 and receiving quality
rank 6 in Full Rate TCH]+
[Uplink receiving level rank 4
and receiving quality rank 6 in
Full Rate TCH]+[Uplink
receiving level rank 5 and
receiving quality rank 6 in Full
Rate TCH]+[Uplink receiving
level rank 0 and receiving
quality rank 7 in Full Rate
TCH]+[Uplink receiving level
rank 1 and receiving quality
rank 7 in Full Rate TCH]+
[Uplink receiving level rank 2
and receiving quality rank 7 in
Full Rate TCH]+[Uplink
receiving level rank 3 and
receiving quality rank 7 in Full
Rate TCH]+[Uplink receiving
level rank 4 and receiving
quality rank 7 in Full Rate
TCH]+[Uplink receiving level
rank 5 and receiving quality
rank 7 in Full Rate TCH]))+
(([Uplink receiving level rank 0
and receiving quality rank 0 in
Full Rate TCH]+[Uplink
receiving level rank 1 and
receiving quality rank 0 in Full
Rate TCH]+[Uplink receiving
level rank 2 and receiving

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 42


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

quality rank 0 in Full Rate


TCH]+[Uplink receiving level
rank 3 and receiving quality
rank 0 in Full Rate TCH]+
[Uplink receiving level rank 4
and receiving quality rank 0 in
Full Rate TCH]+[Uplink
receiving level rank 5 and
receiving quality rank 0 in Full
Rate TCH]+[Uplink receiving
level rank 0 and receiving
quality rank 1 in Full Rate
TCH]+[Uplink receiving level
rank 1 and receiving quality
rank 1 in Full Rate TCH]+
[Uplink receiving level rank 2
and receiving quality rank 1 in
Full Rate TCH]+[Uplink
receiving level rank 3 and
receiving quality rank 1 in Full
Rate TCH]+[Uplink receiving
level rank 4 and receiving
quality rank 1 in Full Rate
TCH]+[Uplink receiving level
rank 5 and receiving quality
rank 1 in Full Rate TCH]))+
(([Uplink receiving level rank 0
and receiving quality rank 2 in
Full Rate TCH]+[Uplink
receiving level rank 1 and
receiving quality rank 2 in Full
Rate TCH]+[Uplink receiving
level rank 2 and receiving
quality rank 2 in Full Rate
TCH]+[Uplink receiving level
rank 3 and receiving quality
rank 2 in Full Rate TCH]+
[Uplink receiving level rank 4
and receiving quality rank 2 in
Full Rate TCH]+[Uplink
receiving level rank 5 and
receiving quality rank 2 in Full
Rate TCH]+[Uplink receiving
level rank 0 and receiving
quality rank 3 in Full Rate
TCH]+[Uplink receiving level
rank 1 and receiving quality

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 43


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

rank 3 in Full Rate TCH]+


[Uplink receiving level rank 2
and receiving quality rank 3 in
Full Rate TCH]+[Uplink
receiving level rank 3 and
receiving quality rank 3 in Full
Rate TCH]+[Uplink receiving
level rank 4 and receiving
quality rank 3 in Full Rate
TCH]+[Uplink receiving level
rank 5 and receiving quality
rank 3 in Full Rate TCH])))*
{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 44


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

TCH Downlink % Full Rate ((([Downlink receiving level


Quality Identifier(%) Receiving rank 0 and receiving quality
Level rank 0 in Full Rate TCH]+
Measuremen [Downlink receiving level rank
t Function 1 and receiving quality rank 0
in Full Rate TCH]+[Downlink
receiving level rank 2 and
receiving quality rank 0 in Full
Rate TCH]+[Downlink
receiving level rank 3 and
receiving quality rank 0 in Full
Rate TCH]+[Downlink
receiving level rank 4 and
receiving quality rank 0 in Full
Rate TCH]+[Downlink
receiving level rank 5 and
receiving quality rank 0 in Full
Rate TCH]+[Downlink
receiving level rank 0 and
receiving quality rank 1 in Full
Rate TCH]+[Downlink
receiving level rank 1 and
receiving quality rank 1 in Full
Rate TCH]+[Downlink
receiving level rank 2 and
receiving quality rank 1 in Full
Rate TCH]+[Downlink
receiving level rank 3 and
receiving quality rank 1 in Full
Rate TCH]+[Downlink
receiving level rank 4 and
receiving quality rank 1 in Full
Rate TCH]+[Downlink
receiving level rank 5 and
receiving quality rank 1 in Full
Rate TCH]))+(([Downlink
receiving level rank 0 and
receiving quality rank 2 in Full
Rate TCH]+[Downlink
receiving level rank 1 and
receiving quality rank 2 in Full
Rate TCH]+[Downlink
receiving level rank 2 and
receiving quality rank 2 in Full
Rate TCH]+[Downlink
receiving level rank 3 and
receiving quality rank 2 in Full

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 45


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Rate TCH]+[Downlink
receiving level rank 4 and
receiving quality rank 2 in Full
Rate TCH]+[Downlink
receiving level rank 5 and
receiving quality rank 2 in Full
Rate TCH]+[Downlink
receiving level rank 0 and
receiving quality rank 3 in Full
Rate TCH]+[Downlink
receiving level rank 1 and
receiving quality rank 3 in Full
Rate TCH]+[Downlink
receiving level rank 2 and
receiving quality rank 3 in Full
Rate TCH]+[Downlink
receiving level rank 3 and
receiving quality rank 3 in Full
Rate TCH]+[Downlink
receiving level rank 4 and
receiving quality rank 3 in Full
Rate TCH]+[Downlink
receiving level rank 5 and
receiving quality rank 3 in Full
Rate TCH])))/((([Uplink
receiving level rank 0 and
receiving quality rank 4 in Full
Rate TCH]+[Uplink receiving
level rank 1 and receiving
quality rank 4 in Full Rate
TCH]+[Uplink receiving level
rank 2 and receiving quality
rank 4 in Full Rate TCH]+
[Uplink receiving level rank 3
and receiving quality rank 4 in
Full Rate TCH]+[Uplink
receiving level rank 4 and
receiving quality rank 4 in Full
Rate TCH]+[Uplink receiving
level rank 5 and receiving
quality rank 4 in Full Rate
TCH]+[Uplink receiving level
rank 0 and receiving quality
rank 5 in Full Rate TCH]+
[Uplink receiving level rank 1
and receiving quality rank 5 in
Full Rate TCH]+[Uplink

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 46


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

receiving level rank 2 and


receiving quality rank 5 in Full
Rate TCH]+[Uplink receiving
level rank 3 and receiving
quality rank 5 in Full Rate
TCH]+[Uplink receiving level
rank 4 and receiving quality
rank 5 in Full Rate TCH]+
[Uplink receiving level rank 5
and receiving quality rank 5 in
Full Rate TCH]))+(([Uplink
receiving level rank 0 and
receiving quality rank 6 in Full
Rate TCH]+[Uplink receiving
level rank 1 and receiving
quality rank 6 in Full Rate
TCH]+[Uplink receiving level
rank 2 and receiving quality
rank 6 in Full Rate TCH]+
[Uplink receiving level rank 3
and receiving quality rank 6 in
Full Rate TCH]+[Uplink
receiving level rank 4 and
receiving quality rank 6 in Full
Rate TCH]+[Uplink receiving
level rank 5 and receiving
quality rank 6 in Full Rate
TCH]+[Uplink receiving level
rank 0 and receiving quality
rank 7 in Full Rate TCH]+
[Uplink receiving level rank 1
and receiving quality rank 7 in
Full Rate TCH]+[Uplink
receiving level rank 2 and
receiving quality rank 7 in Full
Rate TCH]+[Uplink receiving
level rank 3 and receiving
quality rank 7 in Full Rate
TCH]+[Uplink receiving level
rank 4 and receiving quality
rank 7 in Full Rate TCH]+
[Uplink receiving level rank 5
and receiving quality rank 7 in
Full Rate TCH]))+(([Uplink
receiving level rank 0 and
receiving quality rank 0 in Full
Rate TCH]+[Uplink receiving

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 47


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

level rank 1 and receiving


quality rank 0 in Full Rate
TCH]+[Uplink receiving level
rank 2 and receiving quality
rank 0 in Full Rate TCH]+
[Uplink receiving level rank 3
and receiving quality rank 0 in
Full Rate TCH]+[Uplink
receiving level rank 4 and
receiving quality rank 0 in Full
Rate TCH]+[Uplink receiving
level rank 5 and receiving
quality rank 0 in Full Rate
TCH]+[Uplink receiving level
rank 0 and receiving quality
rank 1 in Full Rate TCH]+
[Uplink receiving level rank 1
and receiving quality rank 1 in
Full Rate TCH]+[Uplink
receiving level rank 2 and
receiving quality rank 1 in Full
Rate TCH]+[Uplink receiving
level rank 3 and receiving
quality rank 1 in Full Rate
TCH]+[Uplink receiving level
rank 4 and receiving quality
rank 1 in Full Rate TCH]+
[Uplink receiving level rank 5
and receiving quality rank 1 in
Full Rate TCH]))+(([Uplink
receiving level rank 0 and
receiving quality rank 2 in Full
Rate TCH]+[Uplink receiving
level rank 1 and receiving
quality rank 2 in Full Rate
TCH]+[Uplink receiving level
rank 2 and receiving quality
rank 2 in Full Rate TCH]+
[Uplink receiving level rank 3
and receiving quality rank 2 in
Full Rate TCH]+[Uplink
receiving level rank 4 and
receiving quality rank 2 in Full
Rate TCH]+[Uplink receiving
level rank 5 and receiving
quality rank 2 in Full Rate
TCH]+[Uplink receiving level

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 48


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

rank 0 and receiving quality


rank 3 in Full Rate TCH]+
[Uplink receiving level rank 1
and receiving quality rank 3 in
Full Rate TCH]+[Uplink
receiving level rank 2 and
receiving quality rank 3 in Full
Rate TCH]+[Uplink receiving
level rank 3 and receiving
quality rank 3 in Full Rate
TCH]+[Uplink receiving level
rank 4 and receiving quality
rank 3 in Full Rate TCH]+
[Uplink receiving level rank 5
and receiving quality rank 3 in
Full Rate TCH])))*{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

3.1.3 Accessability Report

Report Type
Simple Report

NE Type
BSC

Object Type
BSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 49


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Accessab Immediate % Random ([Successful immediate


ility Assignment Success Access assignments]/[Immediate
Rate(%) Measuremen assignment requests])*{100}
t Function

TCH Assignment % TCH ([Successful TCH seizures for


Success Rate(%) Measuremen call]/[Attempted TCH seizures
t Function for call])*{100}

TCH Seizures % TCH ([Successful TCH seizures


Success Rate(%) Measuremen (all)]/[Attempted TCH seizures
t Function (all)])*{100}

Call Setup Success % Random (([Successful immediate


Rate Due to BSS(%) Access assignments]/[Immediate
Measuremen assignment requests])*
t Function ([Successful TCH seizures for
call]/[Attempted TCH seizures
for call]))*({1}-[SDCCH call
drop]/[Successful SDCCH
seizures (all)])*{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

3.1.4 Mobility Report

Report Type
Simple Report

NE Type
BSC

Object Type
BSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 50


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Mobility IntraBSC Handover % Inter-cell (([Successful incoming


Success Rate(%) Handover internal inter cell handovers]+
Measuremen [Successful outgoing internal
t Function inter cell handovers]+
[Successful intracell
handovers])/([Attempted
incoming internal inter cell
handovers]+[Attempted
outgoing internal inter cell
handovers]+[Attempted
intracell handovers]))*{100}

IntraBSC Handover % Inter-cell (([Successful incoming


Success Rate Due to Handover internal inter cell handovers]+
Radio Reasons(%) Measuremen [Successful outgoing internal
t Function inter cell handovers]+
[Successful intracell
handovers])/([Incoming
internal inter cell handovers]+
[Outgoing internal inter cell
handovers]+[Attempted
intracell handovers]))*{100}

OutgoingBSC % Inter-cell ([Successful outgoing


Handover Success Handover interBSC inter cell handovers]/
Rate(%) Measuremen [Attempted outgoing interBSC
t Function inter cell handovers])*{100}

OutgoingBSC % Inter-cell ([Successful outgoing


Handover Success Handover interBSC inter cell handovers]/
Rate Due to Radio Measuremen [Inter BSC outgoing cell
Reasons(%) t Function handovers])*{100}

IncomingBSC % Inter-cell ([Successful incoming


Handover Success Handover interBSC inter cell handovers]/
Rate(%) Measuremen [Attempted incoming interBSC
t Function inter cell handovers])*{100}

IncomingBSC % Inter-cell ([Successful incoming


Handover Success Handover interBSC inter cell handovers]/
Rate Due to Radio Measuremen [Inter BSC incoming cell
Reasons(%) t Function handovers])*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 51


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Due-band Handover % Handover (([Successful intercell


Success Rate Measuremen handovers (900/850-
(900-1800)(%) t Function(1) >1800/1900)]+[Successful
incoming BSC handovers
(900/850->1800/1900)]+
[Successful outgoing BSC
handovers (900/850-
>1800/1900)])/([Attempted
intercell handovers (900/850-
>1800/1900)]+[Attempted
incoming BSC handovers
(900/850->1800/1900)]+
[Attempted outgoing BSC
handovers (900/850-
>1800/1900)]))*{100}

Due-band Handover % Handover (([Successful intercell


Success Rate Measuremen handovers (1800/1900-
(1800-900)(%) t Function(1) >900/850)]+[Successful
incoming BSC handovers
(1800/1900->900/850)]+
[Successful outgoing BSC
handovers (1800/1900-
>900/850)])/([Attempted
intercell handovers
(1800/1900->900/850)]+
[Attempted incoming BSC
handovers (1800/1900-
>900/850)]+[Attempted
outgoing BSC handovers
(1800/1900->900/850)]))*
{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 52


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

3.1.5 Availability Report

Report Type
Simple Report

NE Type
BSC

Object Type
BSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Availabil TCH Available Rate % Other [Available TCHs]/


ity (%) Measuremen ([Configured TCHs of 900/850
t Function cell]+[Configured TCHs of
1800/1900 cell])*{100}

SDCCH Available % SDCCH ([Available SDCCHs]/


Rate(%) Measuremen [Configured SDCCHs])*
t Function {100}

TCH Attempt Failure % TCH ([Attempted TCH seizures


Rate Due to No TCH Measuremen meeting TCH overflow]/
Assignment(%) t Function [Attempted TCH seizures
(all)])*{100}

SDCCH Congestion % SDCCH ([Attempted SDCCH seizures


Rate(%) Measuremen meeting SDCCH overflow]/
t Function [Attempted SDCCH seizures
(all)])*{100}

TCH Traffic Volume Erl TCH ([Sum of TCH measurements


per Channel(Erl) Measuremen in the cell (excluding very early
t Function assignment)]*{48}/({100}*
{GP}*{60}))/[Available
TCHs]

TCH Traffic Volume Erl TCH [Sum of TCH measurements in


(Erl) Measuremen the cell (excluding very early
t Function assignment)]*{48}/({100}*
{GP}*{60})

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 53


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Total HalfRate Erl TCHF/H [Sum of TCHH measurements


Traffic Volume(Erl) Measuremen in the cell (excluding very early
t Function(2) assignment)]*{48}/({100}*
{GP}*{60})

Peak percentage of % CPU ([Peak percentage of CPU


CPU occupation(%) Measuremen occupation (%)])
t Function

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

3.2 Special Cell Report

3.2.1 Busy Cell Report

Report Type
Simple Report

NE Type
BSC

Object Type
Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 54


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Busy TCH Traffic Volume Erl TCH ([Sum of TCH measurements


Cell per Channel(Erl) Measuremen in the cell (excluding very early
t Function assignment)]*{48}/({100}*
{GP}*{60}))/[Available
TCHs]

TCH Traffic Volume Erl TCH [Sum of TCH measurements in


(Erl) Measuremen the cell (excluding very early
t Function assignment)]*{48}/({100}*
{GP}*{60})

TCH Available Rate % Other [Available TCHs]/


(%) Measuremen ([Configured TCHs of 900/850
t Function cell]+[Configured TCHs of
1800/1900 cell])*{100}

SDCCH Available % SDCCH ([Available SDCCHs]/


Rate(%) Measuremen [Configured SDCCHs])*
t Function {100}

TCH Congestion % TCH ([TCH seizure failures for call


Rate(including Measuremen (no radio resource)]+
handovers)(%) t Function [Attempted TCH seizures for
very early assignment]-
[Successful TCH seizures for
very early assignment]+[TCH
seizure failures for intraBSC
incoming cell handover(no
radio resource)]+[TCH seizure
failures for interBSC incoming
cell handover(no radio
resource)]+[TCH seizure
failures for intracell handover
(no radio resource)])/
[Attempted TCH seizures (all)]
*{100}

SDCCH Congestion % SDCCH ([Attempted SDCCH seizures


Rate(%) Measuremen meeting SDCCH overflow]/
t Function [Attempted SDCCH seizures
(all)])*{100}

TCH Attempt Failure % TCH ([Attempted TCH seizures


Rate Due to No TCH Measuremen meeting TCH overflow]/
Assignment(%) t Function [Attempted TCH seizures
(all)])*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 55


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Total HalfRate Erl TCHF/H [Sum of TCHH measurements


Traffic Volume(Erl) Measuremen in the cell (excluding very early
t Function(2) assignment)]*{48}/({100}*
{GP}*{60})

Immediate % Random ([Successful immediate


Assignment Success Access assignments]/[Immediate
Rate(%) Measuremen assignment requests])*{100}
t Function

TCH Assignment % TCH ([Successful TCH seizures for


Success Rate(%) Measuremen call]/[Attempted TCH seizures
t Function for call])*{100}

TCH Seizures % TCH ([Successful TCH seizures


Success Rate(%) Measuremen (all)]/[Attempted TCH seizures
t Function (all)])*{100}

Call Setup Success % Random (([Successful immediate


Rate Due to BSS(%) Access assignments]/[Immediate
Measuremen assignment requests])*
t Function ([Successful TCH seizures for
call]/[Attempted TCH seizures
for call]))*({1}-[SDCCH call
drop]/[Successful SDCCH
seizures (all)])*{100}

IntraBSC Handover % Inter-cell (([Successful incoming


Success Rate(%) Handover internal inter cell handovers]+
Measuremen [Successful outgoing internal
t Function inter cell handovers]+
[Successful intracell
handovers])/([Attempted
incoming internal inter cell
handovers]+[Attempted
outgoing internal inter cell
handovers]+[Attempted
intracell handovers]))*{100}

IntraBSC Handover % Inter-cell (([Successful incoming


Success Rate Due to Handover internal inter cell handovers]+
Radio Reasons(%) Measuremen [Successful outgoing internal
t Function inter cell handovers]+
[Successful intracell
handovers])/([Incoming
internal inter cell handovers]+
[Outgoing internal inter cell
handovers]+[Attempted
intracell handovers]))*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 56


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

OutgoingBSC % Inter-cell ([Successful outgoing


Handover Success Handover interBSC inter cell handovers]/
Rate(%) Measuremen [Attempted outgoing interBSC
t Function inter cell handovers])*{100}

OutgoingBSC % Inter-cell ([Successful outgoing


Handover Success Handover interBSC inter cell handovers]/
Rate Due to Radio Measuremen [Inter BSC outgoing cell
Reasons(%) t Function handovers])*{100}

IncomingBSC % Inter-cell ([Successful incoming


Handover Success Handover interBSC inter cell handovers]/
Rate(%) Measuremen [Attempted incoming interBSC
t Function inter cell handovers])*{100}

IncomingBSC % Inter-cell ([Successful incoming


Handover Success Handover interBSC inter cell handovers]/
Rate Due to Radio Measuremen [Inter BSC incoming cell
Reasons(%) t Function handovers])*{100}

TCH Call Drop Rate % TCH ([TCH call drop]+[TCH drop


(including Measuremen for very early assignment])/
handovers)(%) t Function [Successful TCH seizures (all)]
*{100}

TCH Call Drop Rate % TCH [TCH call drop]/([Successful


(excluding Measuremen TCH seizures for call]+
handovers)(%) t Function [Successful TCH allocation for
very early assignment])*{100}

SDCCH Drop Rate % SDCCH ([SDCCH call drop]/


(%) Measuremen [Successful SDCCH seizures
t Function (all)])*{100}

TCH Drop Rate Due % TCH ([TCH lost radio connections


to Radio Link Failure Measuremen (connection failure)]+[TCH
According to all TCH t Function lost radio connections (error
Drop(%) indication)])/[Successful TCH
seizures (all)]*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 57


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

TCH Drop Rate Due % Other (([Unsuccessful internal inter


to Handover Failure Measuremen cell handovers with
(%) t Function unsuccessful reversions]+
[Unsuccessful intracell
handovers with unsuccessful
reversions]+[Unsuccessful
outgoing BSC handovers with
unsuccessful reversion])/
[Successful TCH seizures
(all)])*{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

3.2.2 Idle Cell Report

Report Type
Simple Report

NE Type
BSC

Object Type
Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 58


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Idle Cell TCH Traffic Volume Erl TCH ([Sum of TCH measurements
per Channel(Erl) Measuremen in the cell (excluding very early
t Function assignment)]*{48}/({100}*
{GP}*{60}))/[Available
TCHs]

TCH Traffic Volume Erl TCH [Sum of TCH measurements in


(Erl) Measuremen the cell (excluding very early
t Function assignment)]*{48}/({100}*
{GP}*{60})

TCH Available Rate % Other [Available TCHs]/


(%) Measuremen ([Configured TCHs of 900/850
t Function cell]+[Configured TCHs of
1800/1900 cell])*{100}

SDCCH Available % SDCCH ([Available SDCCHs]/


Rate(%) Measuremen [Configured SDCCHs])*
t Function {100}

TCH Congestion % TCH ([TCH seizure failures for call


Rate(including Measuremen (no radio resource)]+
handovers)(%) t Function [Attempted TCH seizures for
very early assignment]-
[Successful TCH seizures for
very early assignment]+[TCH
seizure failures for intraBSC
incoming cell handover(no
radio resource)]+[TCH seizure
failures for interBSC incoming
cell handover(no radio
resource)]+[TCH seizure
failures for intracell handover
(no radio resource)])/
[Attempted TCH seizures (all)]
*{100}

SDCCH Congestion % SDCCH ([Attempted SDCCH seizures


Rate(%) Measuremen meeting SDCCH overflow]/
t Function [Attempted SDCCH seizures
(all)])*{100}

TCH Attempt Failure % TCH ([Attempted TCH seizures


Rate Due to No TCH Measuremen meeting TCH overflow]/
Assignment(%) t Function [Attempted TCH seizures
(all)])*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 59


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Total HalfRate Erl TCHF/H [Sum of TCHH measurements


Traffic Volume(Erl) Measuremen in the cell (excluding very early
t Function(2) assignment)]*{48}/({100}*
{GP}*{60})

Immediate % Random ([Successful immediate


Assignment Success Access assignments]/[Immediate
Rate(%) Measuremen assignment requests])*{100}
t Function

TCH Assignment % TCH ([Successful TCH seizures for


Success Rate(%) Measuremen call]/[Attempted TCH seizures
t Function for call])*{100}

TCH Seizures % TCH ([Successful TCH seizures


Success Rate(%) Measuremen (all)]/[Attempted TCH seizures
t Function (all)])*{100}

Call Setup Success % Random (([Successful immediate


Rate Due to BSS(%) Access assignments]/[Immediate
Measuremen assignment requests])*
t Function ([Successful TCH seizures for
call]/[Attempted TCH seizures
for call]))*({1}-[SDCCH call
drop]/[Successful SDCCH
seizures (all)])*{100}

IntraBSC Handover % Inter-cell (([Successful incoming


Success Rate(%) Handover internal inter cell handovers]+
Measuremen [Successful outgoing internal
t Function inter cell handovers]+
[Successful intracell
handovers])/([Attempted
incoming internal inter cell
handovers]+[Attempted
outgoing internal inter cell
handovers]+[Attempted
intracell handovers]))*{100}

IntraBSC Handover % Inter-cell (([Successful incoming


Success Rate Due to Handover internal inter cell handovers]+
Radio Reasons(%) Measuremen [Successful outgoing internal
t Function inter cell handovers]+
[Successful intracell
handovers])/([Incoming
internal inter cell handovers]+
[Outgoing internal inter cell
handovers]+[Attempted
intracell handovers]))*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 60


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

OutgoingBSC % Inter-cell ([Successful outgoing


Handover Success Handover interBSC inter cell handovers]/
Rate(%) Measuremen [Attempted outgoing interBSC
t Function inter cell handovers])*{100}

OutgoingBSC % Inter-cell ([Successful outgoing


Handover Success Handover interBSC inter cell handovers]/
Rate Due to Radio Measuremen [Inter BSC outgoing cell
Reasons(%) t Function handovers])*{100}

IncomingBSC % Inter-cell ([Successful incoming


Handover Success Handover interBSC inter cell handovers]/
Rate(%) Measuremen [Attempted incoming interBSC
t Function inter cell handovers])*{100}

IncomingBSC % Inter-cell ([Successful incoming


Handover Success Handover interBSC inter cell handovers]/
Rate Due to Radio Measuremen [Inter BSC incoming cell
Reasons(%) t Function handovers])*{100}

TCH Call Drop Rate % TCH ([TCH call drop]+[TCH drop


(including Measuremen for very early assignment])/
handovers)(%) t Function [Successful TCH seizures (all)]
*{100}

TCH Call Drop Rate % TCH [TCH call drop]/([Successful


(excluding Measuremen TCH seizures for call]+
handovers)(%) t Function [Successful TCH allocation for
very early assignment])*{100}

SDCCH Drop Rate % SDCCH ([SDCCH call drop]/


(%) Measuremen [Successful SDCCH seizures
t Function (all)])*{100}

TCH Drop Rate Due % TCH ([TCH lost radio connections


to Radio Link Failure Measuremen (connection failure)]+[TCH
According to all TCH t Function lost radio connections (error
Drop(%) indication)])/[Successful TCH
seizures (all)]*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 61


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

TCH Drop Rate Due % Other (([Unsuccessful internal inter


to Handover Failure Measuremen cell handovers with
(%) t Function unsuccessful reversions]+
[Unsuccessful intracell
handovers with unsuccessful
reversions]+[Unsuccessful
outgoing BSC handovers with
unsuccessful reversion])/
[Successful TCH seizures
(all)])*{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

3.2.3 Hot Cell Report

Report Type
Simple Report

NE Type
BSC

Object Type
Cell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Hot Cell TCH Traffic Volume Erl TCH [Sum of TCH measurements in
(Erl) Measuremen the cell (excluding very early
t Function assignment)]*{48}/({100}*
{GP}*{60})

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 62


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

TCH Available Rate % Other [Available TCHs]/


(%) Measuremen ([Configured TCHs of 900/850
t Function cell]+[Configured TCHs of
1800/1900 cell])*{100}

SDCCH Available % SDCCH ([Available SDCCHs]/


Rate(%) Measuremen [Configured SDCCHs])*
t Function {100}

TCH Congestion % TCH ([TCH seizure failures for call


Rate(including Measuremen (no radio resource)]+
handovers)(%) t Function [Attempted TCH seizures for
very early assignment]-
[Successful TCH seizures for
very early assignment]+[TCH
seizure failures for intraBSC
incoming cell handover(no
radio resource)]+[TCH seizure
failures for interBSC incoming
cell handover(no radio
resource)]+[TCH seizure
failures for intracell handover
(no radio resource)])/
[Attempted TCH seizures (all)]
*{100}

SDCCH Congestion % SDCCH ([Attempted SDCCH seizures


Rate(%) Measuremen meeting SDCCH overflow]/
t Function [Attempted SDCCH seizures
(all)])*{100}

TCH Traffic Volume Erl TCH ([Sum of TCH measurements


per Channel(Erl) Measuremen in the cell (excluding very early
t Function assignment)]*{48}/({100}*
{GP}*{60}))/[Available
TCHs]

TCH Attempt Failure % TCH ([Attempted TCH seizures


Rate Due to No TCH Measuremen meeting TCH overflow]/
Assignment(%) t Function [Attempted TCH seizures
(all)])*{100}

Total HalfRate Erl TCHF/H [Sum of TCHH measurements


Traffic Volume(Erl) Measuremen in the cell (excluding very early
t Function(2) assignment)]*{48}/({100}*
{GP}*{60})

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 63


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Immediate % Random ([Successful immediate


Assignment Success Access assignments]/[Immediate
Rate(%) Measuremen assignment requests])*{100}
t Function

TCH Assignment % TCH ([Successful TCH seizures for


Success Rate(%) Measuremen call]/[Attempted TCH seizures
t Function for call])*{100}

TCH Seizures % TCH ([Successful TCH seizures


Success Rate(%) Measuremen (all)]/[Attempted TCH seizures
t Function (all)])*{100}

Call Setup Success % Random (([Successful immediate


Rate Due to BSS(%) Access assignments]/[Immediate
Measuremen assignment requests])*
t Function ([Successful TCH seizures for
call]/[Attempted TCH seizures
for call]))*({1}-[SDCCH call
drop]/[Successful SDCCH
seizures (all)])*{100}

IntraBSC Handover % Inter-cell (([Successful incoming


Success Rate(%) Handover internal inter cell handovers]+
Measuremen [Successful outgoing internal
t Function inter cell handovers]+
[Successful intracell
handovers])/([Attempted
incoming internal inter cell
handovers]+[Attempted
outgoing internal inter cell
handovers]+[Attempted
intracell handovers]))*{100}

IntraBSC Handover % Inter-cell (([Successful incoming


Success Rate Due to Handover internal inter cell handovers]+
Radio Reasons(%) Measuremen [Successful outgoing internal
t Function inter cell handovers]+
[Successful intracell
handovers])/([Incoming
internal inter cell handovers]+
[Outgoing internal inter cell
handovers]+[Attempted
intracell handovers]))*{100}

OutgoingBSC % Inter-cell ([Successful outgoing


Handover Success Handover interBSC inter cell handovers]/
Rate(%) Measuremen [Attempted outgoing interBSC
t Function inter cell handovers])*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 64


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

OutgoingBSC % Inter-cell ([Successful outgoing


Handover Success Handover interBSC inter cell handovers]/
Rate Due to Radio Measuremen [Inter BSC outgoing cell
Reasons(%) t Function handovers])*{100}

IncomingBSC % Inter-cell ([Successful incoming


Handover Success Handover interBSC inter cell handovers]/
Rate(%) Measuremen [Attempted incoming interBSC
t Function inter cell handovers])*{100}

IncomingBSC % Inter-cell ([Successful incoming


Handover Success Handover interBSC inter cell handovers]/
Rate Due to Radio Measuremen [Inter BSC incoming cell
Reasons(%) t Function handovers])*{100}

TCH Call Drop Rate % TCH ([TCH call drop]+[TCH drop


(including Measuremen for very early assignment])/
handovers)(%) t Function [Successful TCH seizures (all)]
*{100}

TCH Call Drop Rate % TCH [TCH call drop]/([Successful


(excluding Measuremen TCH seizures for call]+
handovers)(%) t Function [Successful TCH allocation for
very early assignment])*{100}

SDCCH Drop Rate % SDCCH ([SDCCH call drop]/


(%) Measuremen [Successful SDCCH seizures
t Function (all)])*{100}

TCH Drop Rate Due % TCH ([TCH lost radio connections


to Radio Link Failure Measuremen (connection failure)]+[TCH
According to all TCH t Function lost radio connections (error
Drop(%) indication)])/[Successful TCH
seizures (all)]*{100}

TCH Drop Rate Due % Other (([Unsuccessful internal inter


to Handover Failure Measuremen cell handovers with
(%) t Function unsuccessful reversions]+
[Unsuccessful intracell
handovers with unsuccessful
reversions]+[Unsuccessful
outgoing BSC handovers with
unsuccessful reversion])/
[Successful TCH seizures
(all)])*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 65


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

3.2.4 Worst Cell Report

Report Type
Simple Report

NE Type
BSC

Object Type
Cell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Worst TCH Traffic Volume Erl TCH ([Sum of TCH measurements


Cell per Channel(Erl) Measuremen in the cell (excluding very early
t Function assignment)]*{48}/({100}*
{GP}*{60}))/[Available
TCHs]

TCH Call Drop Rate % TCH ([TCH call drop]+[TCH drop


(including Measuremen for very early assignment])/
handovers)(%) t Function [Successful TCH seizures (all)]
*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 66


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

TCH Congestion % TCH ([TCH seizure failures for call


Rate(including Measuremen (no radio resource)]+
handovers)(%) t Function [Attempted TCH seizures for
very early assignment]-
[Successful TCH seizures for
very early assignment]+[TCH
seizure failures for intraBSC
incoming cell handover(no
radio resource)]+[TCH seizure
failures for interBSC incoming
cell handover(no radio
resource)]+[TCH seizure
failures for intracell handover
(no radio resource)])/
[Attempted TCH seizures (all)]
*{100}

TCH Traffic Volume Erl TCH [Sum of TCH measurements in


(Erl) Measuremen the cell (excluding very early
t Function assignment)]*{48}/({100}*
{GP}*{60})

TCH Available Rate % Other [Available TCHs]/


(%) Measuremen ([Configured TCHs of 900/850
t Function cell]+[Configured TCHs of
1800/1900 cell])*{100}

SDCCH Available % SDCCH ([Available SDCCHs]/


Rate(%) Measuremen [Configured SDCCHs])*
t Function {100}

SDCCH Congestion % SDCCH ([Attempted SDCCH seizures


Rate(%) Measuremen meeting SDCCH overflow]/
t Function [Attempted SDCCH seizures
(all)])*{100}

TCH Attempt Failure % TCH ([Attempted TCH seizures


Rate Due to No TCH Measuremen meeting TCH overflow]/
Assignment(%) t Function [Attempted TCH seizures
(all)])*{100}

Total HalfRate Erl TCHF/H [Sum of TCHH measurements


Traffic Volume(Erl) Measuremen in the cell (excluding very early
t Function(2) assignment)]*{48}/({100}*
{GP}*{60})

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 67


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Immediate % Random ([Successful immediate


Assignment Success Access assignments]/[Immediate
Rate(%) Measuremen assignment requests])*{100}
t Function

TCH Assignment % TCH ([Successful TCH seizures for


Success Rate(%) Measuremen call]/[Attempted TCH seizures
t Function for call])*{100}

TCH Seizures % TCH ([Successful TCH seizures


Success Rate(%) Measuremen (all)]/[Attempted TCH seizures
t Function (all)])*{100}

Call Setup Success % Random (([Successful immediate


Rate Due to BSS(%) Access assignments]/[Immediate
Measuremen assignment requests])*
t Function ([Successful TCH seizures for
call]/[Attempted TCH seizures
for call]))*({1}-[SDCCH call
drop]/[Successful SDCCH
seizures (all)])*{100}

IntraBSC Handover % Inter-cell (([Successful incoming


Success Rate(%) Handover internal inter cell handovers]+
Measuremen [Successful outgoing internal
t Function inter cell handovers]+
[Successful intracell
handovers])/([Attempted
incoming internal inter cell
handovers]+[Attempted
outgoing internal inter cell
handovers]+[Attempted
intracell handovers]))*{100}

IntraBSC Handover % Inter-cell (([Successful incoming


Success Rate Due to Handover internal inter cell handovers]+
Radio Reasons(%) Measuremen [Successful outgoing internal
t Function inter cell handovers]+
[Successful intracell
handovers])/([Incoming
internal inter cell handovers]+
[Outgoing internal inter cell
handovers]+[Attempted
intracell handovers]))*{100}

OutgoingBSC % Inter-cell ([Successful outgoing


Handover Success Handover interBSC inter cell handovers]/
Rate(%) Measuremen [Attempted outgoing interBSC
t Function inter cell handovers])*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 68


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

OutgoingBSC % Inter-cell ([Successful outgoing


Handover Success Handover interBSC inter cell handovers]/
Rate Due to Radio Measuremen [Inter BSC outgoing cell
Reasons(%) t Function handovers])*{100}

IncomingBSC % Inter-cell ([Successful incoming


Handover Success Handover interBSC inter cell handovers]/
Rate(%) Measuremen [Attempted incoming interBSC
t Function inter cell handovers])*{100}

IncomingBSC % Inter-cell ([Successful incoming


Handover Success Handover interBSC inter cell handovers]/
Rate Due to Radio Measuremen [Inter BSC incoming cell
Reasons(%) t Function handovers])*{100}

TCH Call Drop Rate % TCH [TCH call drop]/([Successful


(excluding Measuremen TCH seizures for call]+
handovers)(%) t Function [Successful TCH allocation for
very early assignment])*{100}

SDCCH Drop Rate % SDCCH ([SDCCH call drop]/


(%) Measuremen [Successful SDCCH seizures
t Function (all)])*{100}

TCH Drop Rate Due % TCH ([TCH lost radio connections


to Radio Link Failure Measuremen (connection failure)]+[TCH
According to all TCH t Function lost radio connections (error
Drop(%) indication)])/[Successful TCH
seizures (all)]*{100}

TCH Drop Rate Due % Other (([Unsuccessful internal inter


to Handover Failure Measuremen cell handovers with
(%) t Function unsuccessful reversions]+
[Unsuccessful intracell
handovers with unsuccessful
reversions]+[Unsuccessful
outgoing BSC handovers with
unsuccessful reversion])/
[Successful TCH seizures
(all)])*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 69


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

3.3 Cell KPI Report

3.3.1 Retainability Report

Report Type
Simple Report

NE Type
BSC

Object Type
Cell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Retainabi TCH Call Drop Rate % TCH ([TCH call drop]+[TCH drop
lity (including Measuremen for very early assignment])/
handovers)(%) t Function [Successful TCH seizures (all)]
*{100}

TCH Call Drop Rate % TCH [TCH call drop]/([Successful


(excluding Measuremen TCH seizures for call]+
handovers)(%) t Function [Successful TCH allocation for
very early assignment])*{100}

SDCCH Drop Rate % SDCCH ([SDCCH call drop]/


(%) Measuremen [Successful SDCCH seizures
t Function (all)])*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 70


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

TCH Drop Rate Due % TCH ([TCH lost radio connections


to Radio Link Failure Measuremen (connection failure)]+[TCH
According to all TCH t Function lost radio connections (error
Drop(%) indication)])/[Successful TCH
seizures (all)]*{100}

TCH Drop Rate Due % Other (([Unsuccessful internal inter


to Handover Failure Measuremen cell handovers with
(%) t Function unsuccessful reversions]+
[Unsuccessful intracell
handovers with unsuccessful
reversions]+[Unsuccessful
outgoing BSC handovers with
unsuccessful reversion])/
[Successful TCH seizures
(all)])*{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

3.3.2 Service Quality Report

Report Type
Simple Report

NE Type
BSC

Object Type
Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 71


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Service TCH Uplink Quality % Full Rate ((([Uplink receiving level rank
Quality Identifier(%) Receiving 0 and receiving quality rank 0
Level in Full Rate TCH]+[Uplink
Measuremen receiving level rank 1 and
t Function receiving quality rank 0 in Full
Rate TCH]+[Uplink receiving
level rank 2 and receiving
quality rank 0 in Full Rate
TCH]+[Uplink receiving level
rank 3 and receiving quality
rank 0 in Full Rate TCH]+
[Uplink receiving level rank 4
and receiving quality rank 0 in
Full Rate TCH]+[Uplink
receiving level rank 5 and
receiving quality rank 0 in Full
Rate TCH]+[Uplink receiving
level rank 0 and receiving
quality rank 1 in Full Rate
TCH]+[Uplink receiving level
rank 1 and receiving quality
rank 1 in Full Rate TCH]+
[Uplink receiving level rank 2
and receiving quality rank 1 in
Full Rate TCH]+[Uplink
receiving level rank 3 and
receiving quality rank 1 in Full
Rate TCH]+[Uplink receiving
level rank 4 and receiving
quality rank 1 in Full Rate
TCH]+[Uplink receiving level
rank 5 and receiving quality
rank 1 in Full Rate TCH]))+
(([Uplink receiving level rank 0
and receiving quality rank 2 in
Full Rate TCH]+[Uplink
receiving level rank 1 and
receiving quality rank 2 in Full
Rate TCH]+[Uplink receiving
level rank 2 and receiving
quality rank 2 in Full Rate
TCH]+[Uplink receiving level
rank 3 and receiving quality
rank 2 in Full Rate TCH]+
[Uplink receiving level rank 4

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 72


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

and receiving quality rank 2 in


Full Rate TCH]+[Uplink
receiving level rank 5 and
receiving quality rank 2 in Full
Rate TCH]+[Uplink receiving
level rank 0 and receiving
quality rank 3 in Full Rate
TCH]+[Uplink receiving level
rank 1 and receiving quality
rank 3 in Full Rate TCH]+
[Uplink receiving level rank 2
and receiving quality rank 3 in
Full Rate TCH]+[Uplink
receiving level rank 3 and
receiving quality rank 3 in Full
Rate TCH]+[Uplink receiving
level rank 4 and receiving
quality rank 3 in Full Rate
TCH]+[Uplink receiving level
rank 5 and receiving quality
rank 3 in Full Rate TCH])))/
((([Uplink receiving level rank
0 and receiving quality rank 4
in Full Rate TCH]+[Uplink
receiving level rank 1 and
receiving quality rank 4 in Full
Rate TCH]+[Uplink receiving
level rank 2 and receiving
quality rank 4 in Full Rate
TCH]+[Uplink receiving level
rank 3 and receiving quality
rank 4 in Full Rate TCH]+
[Uplink receiving level rank 4
and receiving quality rank 4 in
Full Rate TCH]+[Uplink
receiving level rank 5 and
receiving quality rank 4 in Full
Rate TCH]+[Uplink receiving
level rank 0 and receiving
quality rank 5 in Full Rate
TCH]+[Uplink receiving level
rank 1 and receiving quality
rank 5 in Full Rate TCH]+
[Uplink receiving level rank 2
and receiving quality rank 5 in
Full Rate TCH]+[Uplink
receiving level rank 3 and

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 73


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

receiving quality rank 5 in Full


Rate TCH]+[Uplink receiving
level rank 4 and receiving
quality rank 5 in Full Rate
TCH]+[Uplink receiving level
rank 5 and receiving quality
rank 5 in Full Rate TCH]))+
(([Uplink receiving level rank 0
and receiving quality rank 6 in
Full Rate TCH]+[Uplink
receiving level rank 1 and
receiving quality rank 6 in Full
Rate TCH]+[Uplink receiving
level rank 2 and receiving
quality rank 6 in Full Rate
TCH]+[Uplink receiving level
rank 3 and receiving quality
rank 6 in Full Rate TCH]+
[Uplink receiving level rank 4
and receiving quality rank 6 in
Full Rate TCH]+[Uplink
receiving level rank 5 and
receiving quality rank 6 in Full
Rate TCH]+[Uplink receiving
level rank 0 and receiving
quality rank 7 in Full Rate
TCH]+[Uplink receiving level
rank 1 and receiving quality
rank 7 in Full Rate TCH]+
[Uplink receiving level rank 2
and receiving quality rank 7 in
Full Rate TCH]+[Uplink
receiving level rank 3 and
receiving quality rank 7 in Full
Rate TCH]+[Uplink receiving
level rank 4 and receiving
quality rank 7 in Full Rate
TCH]+[Uplink receiving level
rank 5 and receiving quality
rank 7 in Full Rate TCH]))+
(([Uplink receiving level rank 0
and receiving quality rank 0 in
Full Rate TCH]+[Uplink
receiving level rank 1 and
receiving quality rank 0 in Full
Rate TCH]+[Uplink receiving
level rank 2 and receiving

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 74


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

quality rank 0 in Full Rate


TCH]+[Uplink receiving level
rank 3 and receiving quality
rank 0 in Full Rate TCH]+
[Uplink receiving level rank 4
and receiving quality rank 0 in
Full Rate TCH]+[Uplink
receiving level rank 5 and
receiving quality rank 0 in Full
Rate TCH]+[Uplink receiving
level rank 0 and receiving
quality rank 1 in Full Rate
TCH]+[Uplink receiving level
rank 1 and receiving quality
rank 1 in Full Rate TCH]+
[Uplink receiving level rank 2
and receiving quality rank 1 in
Full Rate TCH]+[Uplink
receiving level rank 3 and
receiving quality rank 1 in Full
Rate TCH]+[Uplink receiving
level rank 4 and receiving
quality rank 1 in Full Rate
TCH]+[Uplink receiving level
rank 5 and receiving quality
rank 1 in Full Rate TCH]))+
(([Uplink receiving level rank 0
and receiving quality rank 2 in
Full Rate TCH]+[Uplink
receiving level rank 1 and
receiving quality rank 2 in Full
Rate TCH]+[Uplink receiving
level rank 2 and receiving
quality rank 2 in Full Rate
TCH]+[Uplink receiving level
rank 3 and receiving quality
rank 2 in Full Rate TCH]+
[Uplink receiving level rank 4
and receiving quality rank 2 in
Full Rate TCH]+[Uplink
receiving level rank 5 and
receiving quality rank 2 in Full
Rate TCH]+[Uplink receiving
level rank 0 and receiving
quality rank 3 in Full Rate
TCH]+[Uplink receiving level
rank 1 and receiving quality

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 75


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

rank 3 in Full Rate TCH]+


[Uplink receiving level rank 2
and receiving quality rank 3 in
Full Rate TCH]+[Uplink
receiving level rank 3 and
receiving quality rank 3 in Full
Rate TCH]+[Uplink receiving
level rank 4 and receiving
quality rank 3 in Full Rate
TCH]+[Uplink receiving level
rank 5 and receiving quality
rank 3 in Full Rate TCH])))*
{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 76


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

TCH Downlink % Full Rate ((([Downlink receiving level


Quality Identifier(%) Receiving rank 0 and receiving quality
Level rank 0 in Full Rate TCH]+
Measuremen [Downlink receiving level rank
t Function 1 and receiving quality rank 0
in Full Rate TCH]+[Downlink
receiving level rank 2 and
receiving quality rank 0 in Full
Rate TCH]+[Downlink
receiving level rank 3 and
receiving quality rank 0 in Full
Rate TCH]+[Downlink
receiving level rank 4 and
receiving quality rank 0 in Full
Rate TCH]+[Downlink
receiving level rank 5 and
receiving quality rank 0 in Full
Rate TCH]+[Downlink
receiving level rank 0 and
receiving quality rank 1 in Full
Rate TCH]+[Downlink
receiving level rank 1 and
receiving quality rank 1 in Full
Rate TCH]+[Downlink
receiving level rank 2 and
receiving quality rank 1 in Full
Rate TCH]+[Downlink
receiving level rank 3 and
receiving quality rank 1 in Full
Rate TCH]+[Downlink
receiving level rank 4 and
receiving quality rank 1 in Full
Rate TCH]+[Downlink
receiving level rank 5 and
receiving quality rank 1 in Full
Rate TCH]))+(([Downlink
receiving level rank 0 and
receiving quality rank 2 in Full
Rate TCH]+[Downlink
receiving level rank 1 and
receiving quality rank 2 in Full
Rate TCH]+[Downlink
receiving level rank 2 and
receiving quality rank 2 in Full
Rate TCH]+[Downlink
receiving level rank 3 and
receiving quality rank 2 in Full

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 77


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Rate TCH]+[Downlink
receiving level rank 4 and
receiving quality rank 2 in Full
Rate TCH]+[Downlink
receiving level rank 5 and
receiving quality rank 2 in Full
Rate TCH]+[Downlink
receiving level rank 0 and
receiving quality rank 3 in Full
Rate TCH]+[Downlink
receiving level rank 1 and
receiving quality rank 3 in Full
Rate TCH]+[Downlink
receiving level rank 2 and
receiving quality rank 3 in Full
Rate TCH]+[Downlink
receiving level rank 3 and
receiving quality rank 3 in Full
Rate TCH]+[Downlink
receiving level rank 4 and
receiving quality rank 3 in Full
Rate TCH]+[Downlink
receiving level rank 5 and
receiving quality rank 3 in Full
Rate TCH])))/((([Uplink
receiving level rank 0 and
receiving quality rank 4 in Full
Rate TCH]+[Uplink receiving
level rank 1 and receiving
quality rank 4 in Full Rate
TCH]+[Uplink receiving level
rank 2 and receiving quality
rank 4 in Full Rate TCH]+
[Uplink receiving level rank 3
and receiving quality rank 4 in
Full Rate TCH]+[Uplink
receiving level rank 4 and
receiving quality rank 4 in Full
Rate TCH]+[Uplink receiving
level rank 5 and receiving
quality rank 4 in Full Rate
TCH]+[Uplink receiving level
rank 0 and receiving quality
rank 5 in Full Rate TCH]+
[Uplink receiving level rank 1
and receiving quality rank 5 in
Full Rate TCH]+[Uplink

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 78


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

receiving level rank 2 and


receiving quality rank 5 in Full
Rate TCH]+[Uplink receiving
level rank 3 and receiving
quality rank 5 in Full Rate
TCH]+[Uplink receiving level
rank 4 and receiving quality
rank 5 in Full Rate TCH]+
[Uplink receiving level rank 5
and receiving quality rank 5 in
Full Rate TCH]))+(([Uplink
receiving level rank 0 and
receiving quality rank 6 in Full
Rate TCH]+[Uplink receiving
level rank 1 and receiving
quality rank 6 in Full Rate
TCH]+[Uplink receiving level
rank 2 and receiving quality
rank 6 in Full Rate TCH]+
[Uplink receiving level rank 3
and receiving quality rank 6 in
Full Rate TCH]+[Uplink
receiving level rank 4 and
receiving quality rank 6 in Full
Rate TCH]+[Uplink receiving
level rank 5 and receiving
quality rank 6 in Full Rate
TCH]+[Uplink receiving level
rank 0 and receiving quality
rank 7 in Full Rate TCH]+
[Uplink receiving level rank 1
and receiving quality rank 7 in
Full Rate TCH]+[Uplink
receiving level rank 2 and
receiving quality rank 7 in Full
Rate TCH]+[Uplink receiving
level rank 3 and receiving
quality rank 7 in Full Rate
TCH]+[Uplink receiving level
rank 4 and receiving quality
rank 7 in Full Rate TCH]+
[Uplink receiving level rank 5
and receiving quality rank 7 in
Full Rate TCH]))+(([Uplink
receiving level rank 0 and
receiving quality rank 0 in Full
Rate TCH]+[Uplink receiving

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 79


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

level rank 1 and receiving


quality rank 0 in Full Rate
TCH]+[Uplink receiving level
rank 2 and receiving quality
rank 0 in Full Rate TCH]+
[Uplink receiving level rank 3
and receiving quality rank 0 in
Full Rate TCH]+[Uplink
receiving level rank 4 and
receiving quality rank 0 in Full
Rate TCH]+[Uplink receiving
level rank 5 and receiving
quality rank 0 in Full Rate
TCH]+[Uplink receiving level
rank 0 and receiving quality
rank 1 in Full Rate TCH]+
[Uplink receiving level rank 1
and receiving quality rank 1 in
Full Rate TCH]+[Uplink
receiving level rank 2 and
receiving quality rank 1 in Full
Rate TCH]+[Uplink receiving
level rank 3 and receiving
quality rank 1 in Full Rate
TCH]+[Uplink receiving level
rank 4 and receiving quality
rank 1 in Full Rate TCH]+
[Uplink receiving level rank 5
and receiving quality rank 1 in
Full Rate TCH]))+(([Uplink
receiving level rank 0 and
receiving quality rank 2 in Full
Rate TCH]+[Uplink receiving
level rank 1 and receiving
quality rank 2 in Full Rate
TCH]+[Uplink receiving level
rank 2 and receiving quality
rank 2 in Full Rate TCH]+
[Uplink receiving level rank 3
and receiving quality rank 2 in
Full Rate TCH]+[Uplink
receiving level rank 4 and
receiving quality rank 2 in Full
Rate TCH]+[Uplink receiving
level rank 5 and receiving
quality rank 2 in Full Rate
TCH]+[Uplink receiving level

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 80


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

rank 0 and receiving quality


rank 3 in Full Rate TCH]+
[Uplink receiving level rank 1
and receiving quality rank 3 in
Full Rate TCH]+[Uplink
receiving level rank 2 and
receiving quality rank 3 in Full
Rate TCH]+[Uplink receiving
level rank 3 and receiving
quality rank 3 in Full Rate
TCH]+[Uplink receiving level
rank 4 and receiving quality
rank 3 in Full Rate TCH]+
[Uplink receiving level rank 5
and receiving quality rank 3 in
Full Rate TCH])))*{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

3.3.3 Accessability Report

Report Type
Simple Report

NE Type
BSC

Object Type
Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 81


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Accessab Immediate % Random ([Successful immediate


ility Assignment Success Access assignments]/[Immediate
Rate(%) Measuremen assignment requests])*{100}
t Function

TCH Assignment % TCH ([Successful TCH seizures for


Success Rate(%) Measuremen call]/[Attempted TCH seizures
t Function for call])*{100}

TCH Seizures % TCH ([Successful TCH seizures


Success Rate(%) Measuremen (all)]/[Attempted TCH seizures
t Function (all)])*{100}

Call Setup Success % Random (([Successful immediate


Rate Due to BSS(%) Access assignments]/[Immediate
Measuremen assignment requests])*
t Function ([Successful TCH seizures for
call]/[Attempted TCH seizures
for call]))*({1}-[SDCCH call
drop]/[Successful SDCCH
seizures (all)])*{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

3.3.4 Mobility Report

Report Type
Simple Report

NE Type
BSC

Object Type
Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 82


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Mobility IntraBSC Handover % Inter-cell (([Successful incoming


Success Rate(%) Handover internal inter cell handovers]+
Measuremen [Successful outgoing internal
t Function inter cell handovers]+
[Successful intracell
handovers])/([Attempted
incoming internal inter cell
handovers]+[Attempted
outgoing internal inter cell
handovers]+[Attempted
intracell handovers]))*{100}

IntraBSC Handover % Inter-cell (([Successful incoming


Success Rate Due to Handover internal inter cell handovers]+
Radio Reasons(%) Measuremen [Successful outgoing internal
t Function inter cell handovers]+
[Successful intracell
handovers])/([Incoming
internal inter cell handovers]+
[Outgoing internal inter cell
handovers]+[Attempted
intracell handovers]))*{100}

OutgoingBSC % Inter-cell ([Successful outgoing


Handover Success Handover interBSC inter cell handovers]/
Rate(%) Measuremen [Attempted outgoing interBSC
t Function inter cell handovers])*{100}

OutgoingBSC % Inter-cell ([Successful outgoing


Handover Success Handover interBSC inter cell handovers]/
Rate Due to Radio Measuremen [Inter BSC outgoing cell
Reasons(%) t Function handovers])*{100}

IncomingBSC % Inter-cell ([Successful incoming


Handover Success Handover interBSC inter cell handovers]/
Rate(%) Measuremen [Attempted incoming interBSC
t Function inter cell handovers])*{100}

IncomingBSC % Inter-cell ([Successful incoming


Handover Success Handover interBSC inter cell handovers]/
Rate Due to Radio Measuremen [Inter BSC incoming cell
Reasons(%) t Function handovers])*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 83


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

3.3.5 Availability Report

Report Type
Simple Report

NE Type
BSC

Object Type
Cell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Availabil TCH Available Rate % Other [Available TCHs]/


ity (%) Measuremen ([Configured TCHs of 900/850
t Function cell]+[Configured TCHs of
1800/1900 cell])*{100}

SDCCH Available % SDCCH ([Available SDCCHs]/


Rate(%) Measuremen [Configured SDCCHs])*
t Function {100}

TCH Attempt Failure % TCH ([Attempted TCH seizures


Rate Due to No TCH Measuremen meeting TCH overflow]/
Assignment(%) t Function [Attempted TCH seizures
(all)])*{100}

SDCCH Congestion % SDCCH ([Attempted SDCCH seizures


Rate(%) Measuremen meeting SDCCH overflow]/
t Function [Attempted SDCCH seizures
(all)])*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 84


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

TCH Congestion % TCH ([TCH seizure failures for call


Rate(including Measuremen (no radio resource)]+
handovers)(%) t Function [Attempted TCH seizures for
very early assignment]-
[Successful TCH seizures for
very early assignment]+[TCH
seizure failures for intraBSC
incoming cell handover(no
radio resource)]+[TCH seizure
failures for interBSC incoming
cell handover(no radio
resource)]+[TCH seizure
failures for intracell handover
(no radio resource)])/
[Attempted TCH seizures (all)]
*{100}

TCH Traffic Volume Erl TCH ([Sum of TCH measurements


per Channel(Erl) Measuremen in the cell (excluding very early
t Function assignment)]*{48}/({100}*
{GP}*{60}))/[Available
TCHs]

TCH Traffic Volume Erl TCH [Sum of TCH measurements in


(Erl) Measuremen the cell (excluding very early
t Function assignment)]*{48}/({100}*
{GP}*{60})

Total HalfRate Erl TCHF/H [Sum of TCHH measurements


Traffic Volume(Erl) Measuremen in the cell (excluding very early
t Function(2) assignment)]*{48}/({100}*
{GP}*{60})

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

3.4 Cell TopN Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 85


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

3.4.1 BSC Handover Success Rate Report

Report Type
Simple Report

NE Type
BSC

Object Type
Cell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

IntraBSC IntraBSC Handover % Inter-cell (([Successful incoming


Handove Success Rate(%) Handover internal inter cell handovers]+
r Success Measuremen [Successful outgoing internal
Rate t Function inter cell handovers]+
[Successful intracell
handovers])/([Attempted
incoming internal inter cell
handovers]+[Attempted
outgoing internal inter cell
handovers]+[Attempted
intracell handovers]))*{100}

IntraBSC Handover % Inter-cell (([Successful incoming


Success Rate Due to Handover internal inter cell handovers]+
Radio Reasons(%) Measuremen [Successful outgoing internal
t Function inter cell handovers]+
[Successful intracell
handovers])/([Incoming
internal inter cell handovers]+
[Outgoing internal inter cell
handovers]+[Attempted
intracell handovers]))*{100}

Outgoing OutgoingBSC % Inter-cell ([Successful outgoing


BSC Handover Success Handover interBSC inter cell handovers]/
Handove Rate(%) Measuremen [Attempted outgoing interBSC
r Success t Function inter cell handovers])*{100}
Rate

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 86


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

OutgoingBSC % Inter-cell ([Successful outgoing


Handover Success Handover interBSC inter cell handovers]/
Rate Due to Radio Measuremen [Inter BSC outgoing cell
Reasons(%) t Function handovers])*{100}

Incoming IncomingBSC % Inter-cell ([Successful incoming


BSC Handover Success Handover interBSC inter cell handovers]/
Handove Rate(%) Measuremen [Attempted incoming interBSC
r Success t Function inter cell handovers])*{100}
Rate
IncomingBSC % Inter-cell ([Successful incoming
Handover Success Handover interBSC inter cell handovers]/
Rate Due to Radio Measuremen [Inter BSC incoming cell
Reasons(%) t Function handovers])*{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

3.4.2 Call Setup Success Rate Due to BSS Report

Report Type
Simple Report

NE Type
BSC

Object Type
Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 87


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Call Call Setup Success % Random (([Successful immediate


Setup Rate Due to BSS(%) Access assignments]/[Immediate
Success Measuremen assignment requests])*
Rate Due t Function ([Successful TCH seizures for
to BSS call]/[Attempted TCH seizures
for call]))*({1}-[SDCCH call
drop]/[Successful SDCCH
seizures (all)])*{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

3.4.3 SDCCH Available Rate Report

Report Type
Simple Report

NE Type
BSC

Object Type
Cell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

SDCCH SDCCH Available % SDCCH ([Available SDCCHs]/


Availabl Rate(%) Measuremen [Configured SDCCHs])*
e Rate t Function {100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 88


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

3.4.4 SDCCH Congestion Rate Report

Report Type
Simple Report

NE Type
BSC

Object Type
Cell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

SDCCH SDCCH Congestion % SDCCH ([Attempted SDCCH seizures


Congesti Rate(%) Measuremen meeting SDCCH overflow]/
on Rate t Function [Attempted SDCCH seizures
(all)])*{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

3.4.5 TCH Call Drop Rate(including handovers) Report

Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 89


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

NE Type
BSC

Object Type
Cell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

TCH Call TCH Call Drop Rate % TCH ([TCH call drop]+[TCH drop
Drop (including Measuremen for very early assignment])/
Rate handovers)(%) t Function [Successful TCH seizures (all)]
(includin *{100}
g
handover TCH Call Drop Rate % TCH [TCH call drop]/([Successful
s) (excluding Measuremen TCH seizures for call]+
handovers)(%) t Function [Successful TCH allocation for
very early assignment])*{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

3.4.6 TCH Available Rate Report

Report Type
Simple Report

NE Type
BSC

Object Type
Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 90


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

TCH TCH Available Rate % Other [Available TCHs]/


Availabl (%) Measuremen ([Configured TCHs of 900/850
e Rate t Function cell]+[Configured TCHs of
1800/1900 cell])*{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

3.4.7 TCH Traffic Volume per Channel Report

Report Type
Simple Report

NE Type
BSC

Object Type
Cell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

TCH TCH Traffic Volume Erl TCH ([Sum of TCH measurements


Traffic per Channel(Erl) Measuremen in the cell (excluding very early
Volume t Function assignment)]*{48}/({100}*
per {GP}*{60}))/[Available
Channel TCHs]
(Max)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 91


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

TCH TCH Traffic Volume Erl TCH ([Sum of TCH measurements


Traffic per Channel(Erl) Measuremen in the cell (excluding very early
Volume t Function assignment)]*{48}/({100}*
per {GP}*{60}))/[Available
Channel TCHs]
(Min)

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

3.4.8 TCH Quality Identifier Report

Report Type
Simple Report

NE Type
BSC

Object Type
Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 92


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

TCH TCH Uplink Quality % Full Rate ((([Uplink receiving level rank
Uplink Identifier(%) Receiving 0 and receiving quality rank 0
Quality Level in Full Rate TCH]+[Uplink
Identifier Measuremen receiving level rank 1 and
t Function receiving quality rank 0 in Full
Rate TCH]+[Uplink receiving
level rank 2 and receiving
quality rank 0 in Full Rate
TCH]+[Uplink receiving level
rank 3 and receiving quality
rank 0 in Full Rate TCH]+
[Uplink receiving level rank 4
and receiving quality rank 0 in
Full Rate TCH]+[Uplink
receiving level rank 5 and
receiving quality rank 0 in Full
Rate TCH]+[Uplink receiving
level rank 0 and receiving
quality rank 1 in Full Rate
TCH]+[Uplink receiving level
rank 1 and receiving quality
rank 1 in Full Rate TCH]+
[Uplink receiving level rank 2
and receiving quality rank 1 in
Full Rate TCH]+[Uplink
receiving level rank 3 and
receiving quality rank 1 in Full
Rate TCH]+[Uplink receiving
level rank 4 and receiving
quality rank 1 in Full Rate
TCH]+[Uplink receiving level
rank 5 and receiving quality
rank 1 in Full Rate TCH]))+
(([Uplink receiving level rank 0
and receiving quality rank 2 in
Full Rate TCH]+[Uplink
receiving level rank 1 and
receiving quality rank 2 in Full
Rate TCH]+[Uplink receiving
level rank 2 and receiving
quality rank 2 in Full Rate
TCH]+[Uplink receiving level
rank 3 and receiving quality
rank 2 in Full Rate TCH]+
[Uplink receiving level rank 4

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 93


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

and receiving quality rank 2 in


Full Rate TCH]+[Uplink
receiving level rank 5 and
receiving quality rank 2 in Full
Rate TCH]+[Uplink receiving
level rank 0 and receiving
quality rank 3 in Full Rate
TCH]+[Uplink receiving level
rank 1 and receiving quality
rank 3 in Full Rate TCH]+
[Uplink receiving level rank 2
and receiving quality rank 3 in
Full Rate TCH]+[Uplink
receiving level rank 3 and
receiving quality rank 3 in Full
Rate TCH]+[Uplink receiving
level rank 4 and receiving
quality rank 3 in Full Rate
TCH]+[Uplink receiving level
rank 5 and receiving quality
rank 3 in Full Rate TCH])))/
((([Uplink receiving level rank
0 and receiving quality rank 4
in Full Rate TCH]+[Uplink
receiving level rank 1 and
receiving quality rank 4 in Full
Rate TCH]+[Uplink receiving
level rank 2 and receiving
quality rank 4 in Full Rate
TCH]+[Uplink receiving level
rank 3 and receiving quality
rank 4 in Full Rate TCH]+
[Uplink receiving level rank 4
and receiving quality rank 4 in
Full Rate TCH]+[Uplink
receiving level rank 5 and
receiving quality rank 4 in Full
Rate TCH]+[Uplink receiving
level rank 0 and receiving
quality rank 5 in Full Rate
TCH]+[Uplink receiving level
rank 1 and receiving quality
rank 5 in Full Rate TCH]+
[Uplink receiving level rank 2
and receiving quality rank 5 in
Full Rate TCH]+[Uplink
receiving level rank 3 and

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 94


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

receiving quality rank 5 in Full


Rate TCH]+[Uplink receiving
level rank 4 and receiving
quality rank 5 in Full Rate
TCH]+[Uplink receiving level
rank 5 and receiving quality
rank 5 in Full Rate TCH]))+
(([Uplink receiving level rank 0
and receiving quality rank 6 in
Full Rate TCH]+[Uplink
receiving level rank 1 and
receiving quality rank 6 in Full
Rate TCH]+[Uplink receiving
level rank 2 and receiving
quality rank 6 in Full Rate
TCH]+[Uplink receiving level
rank 3 and receiving quality
rank 6 in Full Rate TCH]+
[Uplink receiving level rank 4
and receiving quality rank 6 in
Full Rate TCH]+[Uplink
receiving level rank 5 and
receiving quality rank 6 in Full
Rate TCH]+[Uplink receiving
level rank 0 and receiving
quality rank 7 in Full Rate
TCH]+[Uplink receiving level
rank 1 and receiving quality
rank 7 in Full Rate TCH]+
[Uplink receiving level rank 2
and receiving quality rank 7 in
Full Rate TCH]+[Uplink
receiving level rank 3 and
receiving quality rank 7 in Full
Rate TCH]+[Uplink receiving
level rank 4 and receiving
quality rank 7 in Full Rate
TCH]+[Uplink receiving level
rank 5 and receiving quality
rank 7 in Full Rate TCH]))+
(([Uplink receiving level rank 0
and receiving quality rank 0 in
Full Rate TCH]+[Uplink
receiving level rank 1 and
receiving quality rank 0 in Full
Rate TCH]+[Uplink receiving
level rank 2 and receiving

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 95


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

quality rank 0 in Full Rate


TCH]+[Uplink receiving level
rank 3 and receiving quality
rank 0 in Full Rate TCH]+
[Uplink receiving level rank 4
and receiving quality rank 0 in
Full Rate TCH]+[Uplink
receiving level rank 5 and
receiving quality rank 0 in Full
Rate TCH]+[Uplink receiving
level rank 0 and receiving
quality rank 1 in Full Rate
TCH]+[Uplink receiving level
rank 1 and receiving quality
rank 1 in Full Rate TCH]+
[Uplink receiving level rank 2
and receiving quality rank 1 in
Full Rate TCH]+[Uplink
receiving level rank 3 and
receiving quality rank 1 in Full
Rate TCH]+[Uplink receiving
level rank 4 and receiving
quality rank 1 in Full Rate
TCH]+[Uplink receiving level
rank 5 and receiving quality
rank 1 in Full Rate TCH]))+
(([Uplink receiving level rank 0
and receiving quality rank 2 in
Full Rate TCH]+[Uplink
receiving level rank 1 and
receiving quality rank 2 in Full
Rate TCH]+[Uplink receiving
level rank 2 and receiving
quality rank 2 in Full Rate
TCH]+[Uplink receiving level
rank 3 and receiving quality
rank 2 in Full Rate TCH]+
[Uplink receiving level rank 4
and receiving quality rank 2 in
Full Rate TCH]+[Uplink
receiving level rank 5 and
receiving quality rank 2 in Full
Rate TCH]+[Uplink receiving
level rank 0 and receiving
quality rank 3 in Full Rate
TCH]+[Uplink receiving level
rank 1 and receiving quality

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 96


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

rank 3 in Full Rate TCH]+


[Uplink receiving level rank 2
and receiving quality rank 3 in
Full Rate TCH]+[Uplink
receiving level rank 3 and
receiving quality rank 3 in Full
Rate TCH]+[Uplink receiving
level rank 4 and receiving
quality rank 3 in Full Rate
TCH]+[Uplink receiving level
rank 5 and receiving quality
rank 3 in Full Rate TCH])))*
{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 97


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

TCH TCH Downlink % Full Rate ((([Downlink receiving level


Downlin Quality Identifier(%) Receiving rank 0 and receiving quality
k Quality Level rank 0 in Full Rate TCH]+
Identifier Measuremen [Downlink receiving level rank
t Function 1 and receiving quality rank 0
in Full Rate TCH]+[Downlink
receiving level rank 2 and
receiving quality rank 0 in Full
Rate TCH]+[Downlink
receiving level rank 3 and
receiving quality rank 0 in Full
Rate TCH]+[Downlink
receiving level rank 4 and
receiving quality rank 0 in Full
Rate TCH]+[Downlink
receiving level rank 5 and
receiving quality rank 0 in Full
Rate TCH]+[Downlink
receiving level rank 0 and
receiving quality rank 1 in Full
Rate TCH]+[Downlink
receiving level rank 1 and
receiving quality rank 1 in Full
Rate TCH]+[Downlink
receiving level rank 2 and
receiving quality rank 1 in Full
Rate TCH]+[Downlink
receiving level rank 3 and
receiving quality rank 1 in Full
Rate TCH]+[Downlink
receiving level rank 4 and
receiving quality rank 1 in Full
Rate TCH]+[Downlink
receiving level rank 5 and
receiving quality rank 1 in Full
Rate TCH]))+(([Downlink
receiving level rank 0 and
receiving quality rank 2 in Full
Rate TCH]+[Downlink
receiving level rank 1 and
receiving quality rank 2 in Full
Rate TCH]+[Downlink
receiving level rank 2 and
receiving quality rank 2 in Full
Rate TCH]+[Downlink
receiving level rank 3 and
receiving quality rank 2 in Full

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 98


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Rate TCH]+[Downlink
receiving level rank 4 and
receiving quality rank 2 in Full
Rate TCH]+[Downlink
receiving level rank 5 and
receiving quality rank 2 in Full
Rate TCH]+[Downlink
receiving level rank 0 and
receiving quality rank 3 in Full
Rate TCH]+[Downlink
receiving level rank 1 and
receiving quality rank 3 in Full
Rate TCH]+[Downlink
receiving level rank 2 and
receiving quality rank 3 in Full
Rate TCH]+[Downlink
receiving level rank 3 and
receiving quality rank 3 in Full
Rate TCH]+[Downlink
receiving level rank 4 and
receiving quality rank 3 in Full
Rate TCH]+[Downlink
receiving level rank 5 and
receiving quality rank 3 in Full
Rate TCH])))/((([Uplink
receiving level rank 0 and
receiving quality rank 4 in Full
Rate TCH]+[Uplink receiving
level rank 1 and receiving
quality rank 4 in Full Rate
TCH]+[Uplink receiving level
rank 2 and receiving quality
rank 4 in Full Rate TCH]+
[Uplink receiving level rank 3
and receiving quality rank 4 in
Full Rate TCH]+[Uplink
receiving level rank 4 and
receiving quality rank 4 in Full
Rate TCH]+[Uplink receiving
level rank 5 and receiving
quality rank 4 in Full Rate
TCH]+[Uplink receiving level
rank 0 and receiving quality
rank 5 in Full Rate TCH]+
[Uplink receiving level rank 1
and receiving quality rank 5 in
Full Rate TCH]+[Uplink

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 99


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

receiving level rank 2 and


receiving quality rank 5 in Full
Rate TCH]+[Uplink receiving
level rank 3 and receiving
quality rank 5 in Full Rate
TCH]+[Uplink receiving level
rank 4 and receiving quality
rank 5 in Full Rate TCH]+
[Uplink receiving level rank 5
and receiving quality rank 5 in
Full Rate TCH]))+(([Uplink
receiving level rank 0 and
receiving quality rank 6 in Full
Rate TCH]+[Uplink receiving
level rank 1 and receiving
quality rank 6 in Full Rate
TCH]+[Uplink receiving level
rank 2 and receiving quality
rank 6 in Full Rate TCH]+
[Uplink receiving level rank 3
and receiving quality rank 6 in
Full Rate TCH]+[Uplink
receiving level rank 4 and
receiving quality rank 6 in Full
Rate TCH]+[Uplink receiving
level rank 5 and receiving
quality rank 6 in Full Rate
TCH]+[Uplink receiving level
rank 0 and receiving quality
rank 7 in Full Rate TCH]+
[Uplink receiving level rank 1
and receiving quality rank 7 in
Full Rate TCH]+[Uplink
receiving level rank 2 and
receiving quality rank 7 in Full
Rate TCH]+[Uplink receiving
level rank 3 and receiving
quality rank 7 in Full Rate
TCH]+[Uplink receiving level
rank 4 and receiving quality
rank 7 in Full Rate TCH]+
[Uplink receiving level rank 5
and receiving quality rank 7 in
Full Rate TCH]))+(([Uplink
receiving level rank 0 and
receiving quality rank 0 in Full
Rate TCH]+[Uplink receiving

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 100


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

level rank 1 and receiving


quality rank 0 in Full Rate
TCH]+[Uplink receiving level
rank 2 and receiving quality
rank 0 in Full Rate TCH]+
[Uplink receiving level rank 3
and receiving quality rank 0 in
Full Rate TCH]+[Uplink
receiving level rank 4 and
receiving quality rank 0 in Full
Rate TCH]+[Uplink receiving
level rank 5 and receiving
quality rank 0 in Full Rate
TCH]+[Uplink receiving level
rank 0 and receiving quality
rank 1 in Full Rate TCH]+
[Uplink receiving level rank 1
and receiving quality rank 1 in
Full Rate TCH]+[Uplink
receiving level rank 2 and
receiving quality rank 1 in Full
Rate TCH]+[Uplink receiving
level rank 3 and receiving
quality rank 1 in Full Rate
TCH]+[Uplink receiving level
rank 4 and receiving quality
rank 1 in Full Rate TCH]+
[Uplink receiving level rank 5
and receiving quality rank 1 in
Full Rate TCH]))+(([Uplink
receiving level rank 0 and
receiving quality rank 2 in Full
Rate TCH]+[Uplink receiving
level rank 1 and receiving
quality rank 2 in Full Rate
TCH]+[Uplink receiving level
rank 2 and receiving quality
rank 2 in Full Rate TCH]+
[Uplink receiving level rank 3
and receiving quality rank 2 in
Full Rate TCH]+[Uplink
receiving level rank 4 and
receiving quality rank 2 in Full
Rate TCH]+[Uplink receiving
level rank 5 and receiving
quality rank 2 in Full Rate
TCH]+[Uplink receiving level

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 101


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

rank 0 and receiving quality


rank 3 in Full Rate TCH]+
[Uplink receiving level rank 1
and receiving quality rank 3 in
Full Rate TCH]+[Uplink
receiving level rank 2 and
receiving quality rank 3 in Full
Rate TCH]+[Uplink receiving
level rank 3 and receiving
quality rank 3 in Full Rate
TCH]+[Uplink receiving level
rank 4 and receiving quality
rank 3 in Full Rate TCH]+
[Uplink receiving level rank 5
and receiving quality rank 3 in
Full Rate TCH])))*{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

3.4.9 TCH Attempt Failure Rate Due to No TCH Assignment Report

Report Type
Simple Report

NE Type
BSC

Object Type
Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 102


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

TCH TCH Attempt Failure % TCH ([Attempted TCH seizures


Attempt Rate Due to No TCH Measuremen meeting TCH overflow]/
Failure Assignment(%) t Function [Attempted TCH seizures
Rate Due (all)])*{100}
to No
TCH
Assignm
ent

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

3.4.10 TCH Seizures Success Rate Report


Report Type
Simple Report

NE Type
BSC

Object Type
Cell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

TCH TCH Seizures % TCH ([Successful TCH seizures


Seizures Success Rate(%) Measuremen (all)]/[Attempted TCH seizures
Success t Function (all)])*{100}
Rate

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 103


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

3.4.11 TCH Assignment Success Rate Report


Report Type
Simple Report

NE Type
BSC

Object Type
Cell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

TCH TCH Assignment % TCH ([Successful TCH seizures for


Assignm Success Rate(%) Measuremen call]/[Attempted TCH seizures
ent t Function for call])*{100}
Success
Rate

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

3.4.12 Immediate Assignment Success Rate Report


Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 104


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 3 BSC32 Performance Report

NE Type
BSC

Object Type
Cell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Immediat Immediate % Random ([Successful immediate


e Assignment Success Access assignments]/[Immediate
Assignm Rate(%) Measuremen assignment requests])*{100}
ent t Function
Success
Rate

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 105


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 4 GSM BSS NHC Report

4 GSM BSS NHC Report

About This Chapter

4.1 High Call Drop Rate Cell(Night Busy Time)

4.2 High Call Drop Rate Cell(Morning Busy Time)

4.3 High Congestion Rate Cell(Night Busy Time)

4.4 High Congestion Rate Cell(Morning Busy Time)

4.5 Traffic Volume Measurement

4.6 Cell Performance Measurement(Night Busy Time)

4.7 Cell Performance Measurement(Morning Busy Time)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 106


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 4 GSM BSS NHC Report

4.1 High Call Drop Rate Cell(Night Busy Time)


Report Type
Simple Report

NE Type
BSC6900GSM, BSC6000

Object Type
GCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

High Call TCH Congestion(All % Channel ([K3020:TCH Seizure


Drop Busy)(%) Configuratio Requests (Signaling Channel)]
Rate Cell n +[K3010A:TCH Seizure
Measuremen Requests (Traffic Channel)]+
t per Cell [K3010B:TCH Seizure
Requests in TCH Handovers
(Traffic Channel)]-
[CR443B:Completed
Handovers])/([K3020:TCH
Seizure Requests (Signaling
Channel)]+[K3010A:TCH
Seizure Requests (Traffic
Channel)]+[K3010B:TCH
Seizure Requests in TCH
Handovers (Traffic Channel)])
*{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 107


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 4 GSM BSS NHC Report

4.2 High Call Drop Rate Cell(Morning Busy Time)


Report Type
Simple Report

NE Type
BSC6900GSM, BSC6000

Object Type
GCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

High Call TCH Congestion(All % Channel ([K3020:TCH Seizure


Drop Busy)(%) Configuratio Requests (Signaling Channel)]
Rate Cell n +[K3010A:TCH Seizure
Measuremen Requests (Traffic Channel)]+
t per Cell [K3010B:TCH Seizure
Requests in TCH Handovers
(Traffic Channel)]-
[CR443B:Completed
Handovers])/([K3020:TCH
Seizure Requests (Signaling
Channel)]+[K3010A:TCH
Seizure Requests (Traffic
Channel)]+[K3010B:TCH
Seizure Requests in TCH
Handovers (Traffic Channel)])
*{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 108


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 4 GSM BSS NHC Report

4.3 High Congestion Rate Cell(Night Busy Time)


Report Type
Simple Report

NE Type
BSC6900GSM, BSC6000

Object Type
GCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

High TCH Taffic(Erl) Erl KPI ([R3551A:Number of Busy


Congesti Measuremen Traffic Channels (TCHF)
on Rate t per Cell (900/850/810 band)]+
Cell [R3551B:Number of Busy
Traffic Channels (TCHF)
(1800/1900 Band)]+
[R3552A:Number of Busy
Traffic Channels (TCHH)
(900/850/810 band)]+
[R3552B:Number of Busy
Traffic Channels (TCHH)
(1800/1900 Band)])/
[R359:Number of Attempts to
Scan Channel States]

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 109


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 4 GSM BSS NHC Report

4.4 High Congestion Rate Cell(Morning Busy Time)


Report Type
Simple Report

NE Type
BSC6900GSM, BSC6000

Object Type
GCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

High TCH Taffic(Erl) Erl KPI ([R3551A:Number of Busy


Congesti Measuremen Traffic Channels (TCHF)
on Rate t per Cell (900/850/810 band)]+
Cell [R3551B:Number of Busy
Traffic Channels (TCHF)
(1800/1900 Band)]+
[R3552A:Number of Busy
Traffic Channels (TCHH)
(900/850/810 band)]+
[R3552B:Number of Busy
Traffic Channels (TCHH)
(1800/1900 Band)])/
[R359:Number of Attempts to
Scan Channel States]

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 110


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 4 GSM BSS NHC Report

4.5 Traffic Volume Measurement


Report Type
Simple Report

NE Type
BSC6900GSM, BSC6000

Object Type
GBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Traffic TCH Drop Rate(with % Channel [CM33:Call Drops on Traffic


Volume HO)(%) State Channel]/([K3023:Successful
Measure Measuremen TCH Seizures (Signaling
ment t per Cell Channel)]+[K3010A:TCH
Seizure Requests (Traffic
Channel)]+[K3013B:Success-
ful TCH Seizures in TCH
handovers (Traffic Channel)])*
{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

4.6 Cell Performance Measurement(Night Busy Time)


Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 111


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 4 GSM BSS NHC Report

NE Type
BSC6900GSM, BSC6000

Object Type
GCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Cell TCH Drop Rate(with % Channel [CM33:Call Drops on Traffic


Performa HO)(%) State Channel]/([K3023:Successful
nce Measuremen TCH Seizures (Signaling
Measure t per Cell Channel)]+[K3010A:TCH
ment Seizure Requests (Traffic
Channel)]+[K3013B:Success-
ful TCH Seizures in TCH
handovers (Traffic Channel)])*
{100}

TCH Taffic(Erl) Erl KPI ([R3551A:Number of Busy


Measuremen Traffic Channels (TCHF)
t per Cell (900/850/810 band)]+
[R3551B:Number of Busy
Traffic Channels (TCHF)
(1800/1900 Band)]+
[R3552A:Number of Busy
Traffic Channels (TCHH)
(900/850/810 band)]+
[R3552B:Number of Busy
Traffic Channels (TCHH)
(1800/1900 Band)])/
[R359:Number of Attempts to
Scan Channel States]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 112


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 4 GSM BSS NHC Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

TCH Congestion(All % Channel ([K3020:TCH Seizure


Busy)(%) Configuratio Requests (Signaling Channel)]
n +[K3010A:TCH Seizure
Measuremen Requests (Traffic Channel)]+
t per Cell [K3010B:TCH Seizure
Requests in TCH Handovers
(Traffic Channel)]-
[CR443B:Completed
Handovers])/([K3020:TCH
Seizure Requests (Signaling
Channel)]+[K3010A:TCH
Seizure Requests (Traffic
Channel)]+[K3010B:TCH
Seizure Requests in TCH
Handovers (Traffic Channel)])
*{100}

TCH availability(%) % Call Drop {100}*[CR3027:Mean


Measuremen Number of Available Channels
t per Cell (TCHF)]/[CR301B:Mean
Number of Dynamically
Configured Channels (TCH)]

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

4.7 Cell Performance Measurement(Morning Busy Time)


Report Type
Simple Report

NE Type
BSC6900GSM, BSC6000

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 113


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 4 GSM BSS NHC Report

Object Type
GCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Cell TCH Drop Rate(with % Channel [CM33:Call Drops on Traffic


Performa HO)(%) State Channel]/([K3023:Successful
nce Measuremen TCH Seizures (Signaling
Measure t per Cell Channel)]+[K3010A:TCH
ment Seizure Requests (Traffic
Channel)]+[K3013B:Success-
ful TCH Seizures in TCH
handovers (Traffic Channel)])*
{100}

TCH Taffic(Erl) Erl KPI ([R3551A:Number of Busy


Measuremen Traffic Channels (TCHF)
t per Cell (900/850/810 band)]+
[R3551B:Number of Busy
Traffic Channels (TCHF)
(1800/1900 Band)]+
[R3552A:Number of Busy
Traffic Channels (TCHH)
(900/850/810 band)]+
[R3552B:Number of Busy
Traffic Channels (TCHH)
(1800/1900 Band)])/
[R359:Number of Attempts to
Scan Channel States]

TCH Congestion(All % Channel ([K3020:TCH Seizure


Busy)(%) Configuratio Requests (Signaling Channel)]
n +[K3010A:TCH Seizure
Measuremen Requests (Traffic Channel)]+
t per Cell [K3010B:TCH Seizure
Requests in TCH Handovers
(Traffic Channel)]-
[CR443B:Completed
Handovers])/([K3020:TCH
Seizure Requests (Signaling
Channel)]+[K3010A:TCH
Seizure Requests (Traffic
Channel)]+[K3010B:TCH
Seizure Requests in TCH
Handovers (Traffic Channel)])
*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 114


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 4 GSM BSS NHC Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

TCH availability(%) % Call Drop {100}*[CR3027:Mean


Measuremen Number of Available Channels
t per Cell (TCHF)]/[CR301B:Mean
Number of Dynamically
Configured Channels (TCH)]

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 115


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

5 GSM BSS Performance Report

About This Chapter

5.1 Average Sending Throughput Rate Report

5.2 Local Switch Report

5.3 Service Identification Qos Report

5.4 VAMOS Performance Report

5.5 BSC KPI Overview Report

5.6 GSM BSC KPI Report

5.7 GSM Network Performance Monitoring Report (Engineer)

5.8 GSM Network Performance Monitoring Report (Team Leader)

5.9 Retainability Report

5.10 Extra Busy Cell Report

5.11 Extra Idle Cell Report

5.12 Call Drop Cell Report

5.13 Accessibility Report

5.14 Whole Network KPI Report

5.15 Mobility Report

5.16 Congestion Cell Report

5.17 Resource Utilization Report

5.18 Worst Cell Report

5.19 BTS Energy Consumption Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 116


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

5.1 Average Sending Throughput Rate Report

5.1.1 LGCPRT MEAN TXRATE Report

Report Type
Simple Report

NE Type
BSC6900GSM, BSC6000

Object Type
LOGIC PORT

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

LGCPRT T7507:Average kbit/s Logical Port -


MEAN Transmit Rate of Measuremen
TXRAT Logical Port t
E

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

5.1.2 MLPPP TXMEANSPEED Report

Report Type
Simple Report

NE Type
BSC6900GSM, BSC6000

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 117


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Object Type
MLPPP

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

MLPPP T7313:Mean kbit/s MP Group -


TXMEA Transmit Rate of an Measuremen
NSPEED MP Group t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

5.1.3 PPP TXMEANSPEED Report

Report Type
Simple Report

NE Type
BSC6900GSM, BSC6000

Object Type
PPP

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

PPP T7358:Average kbit/s PPP Link -


TXMEA Transmit Rate of a Measuremen
NSPEED PPP Link t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 118


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

5.2 Local Switch Report

5.2.1 BSC LCLS USER RATE Report

Report Type
Simple Report

NE Type
BSC6900GSM, BSC6000

Object Type
GBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

BSC Rate of BSC local % Call Drop [R3830:Number of Successful


LCLS user switching Measuremen BSC local switching
USER t per BSC Attempts]/([M318:Successful
RATE Connections (TCHF) (Traffic
Channel)]+[M328:Successful
Connections (TCHH) (Traffic
Channel)])

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 119


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

5.2.2 SITE CS USED TS RATE Report

Report Type
Simple Report

NE Type
BSC6900GSM, BSC6000

Object Type
BTS

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

SITE CS T66001:Timeslot none Utilization of -


USED Utilization Rate of BTS
TS CS Service In a BTS Timeslots
RATE

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

5.2.3 SITE LCLS USER RATE Report

Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 120


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

NE Type
BSC6900GSM, BSC6000

Object Type
GBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

SITE Rate of BTS local % Local Switch ([M318:Successful


LCLS user switching Measuremen Connections (TCHF) (Traffic
USER t per Cell Channel)]+[M328:Successful
RATE Connections (TCHH) (Traffic
Channel)])/[R3831:Number of
Successful BTS local
switching Attempts]

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

5.3 Service Identification Qos Report

5.3.1 Cell Performance KPI Report

CS Performance KPI Report

Report Type
Simple Report

NE Type
BSC6900GSM, BSC6000

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 121


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Object Type
GCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

CS RR370:Congestion % Channel -
Performa Rate on SDCCH per Assignment
nce KPI CELL (due to Busy) Failure
Measuremen
t per Cell

K3045:Congestion % KPI -
Rate on TCH (All Measuremen
Channels Busy) t per Cell

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

PS Performance KPI Report

Report Type
Simple Report

NE Type
BSC6900GSM, BSC6000

Object Type
GCell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 122


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

PS A9513:Successful none Packet -


Performa Uplink Assignment Assignment
nce KPI Rate Capability
Measuremen
t

A9514:Successful none Packet -


Downlink Assignment
Assignment Rate Capability
Measuremen
t

Uplink TBF none Uplink ([A9003:Number of Failed


Congestion Rate GPRS TBF Uplink GPRS TBF
Establish and Establishments due to No
Release Channel]+[A9203:Number of
Capability Failed Uplink EGPRS TBF
Measuremen Establishments due to No
t Channel])/([A9001:Number of
Uplink GPRS TBF
Establishment Attempts]+
[A9201:Number of Uplink
EGPRS TBF Establishment
Attempts])*{100}

Downlink TBF none Downlink ([A9103:Number of Failed


Congestion Rate GPRS TBF Downlink GPRS TBF
Establish and Establishments due to No
Release Channel]+[A9303:Number of
Capability Failed Downlink EGPRS TBF
Measuremen Establishments due to No
t Channel])/([A9101:Number of
Downlink GPRS TBF
Establishment Attempts]+
[A9301:Number of Downlink
EGPRS TBF Establishment
Attempts])*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 123


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Uplink TBF Drop none Uplink ([A9006:Number of Uplink


Rate(%) GPRS TBF GPRS TBF Abnormal Releases
Establish and due to N3101 Overflow (MS
Release No Response)]+
Capability [A9007:Number of Uplink
Measuremen GPRS TBF Abnormal Releases
t due to N3103 Overflow (MS
No Response)]+
[A9206:Number of Uplink
EGPRS TBF Abnormal
Releases due to N3101
Overflow (MS No Response)]+
[A9207:Number of Uplink
EGPRS TBF Abnormal
Releases due to N3103
Overflow (MS No
Response)])/([A9002:Number
of Successful Uplink GPRS
TBF Establishments]+
[A9202:Number of Successful
Uplink EGPRS TBF
Establishments])*{100}

Downlink TBF Drop none Downlink ([A9118:Number of Downlink


Rate(%) GPRS TBF GPRS Intermit Transfers]+
Establish and [A9318:Number of Downlink
Release EGPRS Intermit Transfers])/
Capability ([A9102:Number of Successful
Measuremen Downlink GPRS TBF
t Establishments]+
[A9302:Number of Successful
Downlink EGPRS TBF
Establishments])*{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

5.3.2 PDCHs Occupied by TBF Performance Analysis Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 124


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

PDCHs Occupied by Downlink TBF Report

Report Type
Simple Report

NE Type
BSC6900GSM, BSC6000

Object Type
GCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

PDCHs Average Number of numb PDCH [AR9321:Average Number of


Occupied TCHs Occupied by er Resource Occupied Static EGPRS
by EGPRS PDCH Capability PDCHs]+[AR9323:Average
Downlin Measuremen Number of Occupied Dynamic
k TBF t EGPRS PDCHs]

AR9319:Average none PDCH -


Number of Occupied Resource
GPRS PDCHs Capability
Measuremen
t

AR9379:Average none PDCH -


Number of Resource
Concurrent Capability
Downlink EGPRS Measuremen
TBFs on EGPRS t
PDCH

AR9375:Average none PDCH -


Number of Resource
Concurrent Capability
Downlink GPRS Measuremen
TBFs on EGPRS t
PDCH

Average Number of numb PDCH [AR9379:Average Number of


Concurrent er Resource Concurrent Downlink EGPRS
Downlink TBFs on Capability TBFs on EGPRS PDCH]+
per EGPRS PDCH Measuremen [AR9375:Average Number of
t Concurrent Downlink GPRS
TBFs on EGPRS PDCH]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 125


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

AR9371:Average none PDCH -


Number of Resource
Concurrent Capability
Downlink GPRS Measuremen
TBFs on GPRS t
PDCH

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

PDCHs Occupied by Uplink TBF Report

Report Type
Simple Report

NE Type
BSC6900GSM, BSC6000

Object Type
GCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

PDCHs Average Number of numb PDCH [AR9321:Average Number of


Occupied TCHs Occupied by er Resource Occupied Static EGPRS
by EGPRS PDCH Capability PDCHs]+[AR9323:Average
Uplink Measuremen Number of Occupied Dynamic
TBF t EGPRS PDCHs]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 126


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

AR9319:Average none PDCH -


Number of Occupied Resource
GPRS PDCHs Capability
Measuremen
t

AR9377:Average none PDCH -


Number of Resource
Concurrent Uplink Capability
EGPRS TBFs on Measuremen
EGPRS PDCH t

AR9373:Average none PDCH -


Number of Resource
Concurrent Uplink Capability
GPRS TBFs on Measuremen
EGPRS PDCH t

Average Number of numb PDCH [AR9377:Average Number of


Concurrent Uplink er Resource Concurrent Uplink EGPRS
TBFs on per EGPRS Capability TBFs on EGPRS PDCH]+
PDCH Measuremen [AR9373:Average Number of
t Concurrent Uplink GPRS
TBFs on EGPRS PDCH]

AR9369:Average none PDCH -


Number of Resource
Concurrent Uplink Capability
GPRS TBFs on Measuremen
GPRS PDCH t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

5.3.3 Signaling Performance Analysis Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 127


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Paging Performance Report

Report Type
Simple Report

NE Type
BSC6900GSM, BSC6000

Object Type
GCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Paging A330:Delivered none Abis -


Performa Paging Messages for Interface
nce CS Service Paging
Measuremen
t per Cell

A331:Delivered none Abis -


Paging Messages for Interface
PS Service Paging
Measuremen
t per Cell

A338:Number of none Abis -


Expiries of the Interface
Paging for CS Paging
Services on the PCH Measuremen
t per Cell

A340:Number of none Abis -


Expiries of the Interface
Paging for PS Paging
Services on the PCH Measuremen
t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 128


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

TBF Assignment Report

Report Type
Simple Report

NE Type
BSC6900GSM, BSC6000

Object Type
GCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

TBF ZA9503:Number of none Packet -


Assignm Uplink PS Immediate Assignment
ent Assignments per Capability
BSC Measuremen
t per BSC

ZA9505:Number of none Packet -


Uplink Assignments Assignment
on PACCH per BSC Capability
Measuremen
t per BSC

ZA9509:Number of none Packet -


Downlink PS Assignment
Immediate Capability
Assignments per Measuremen
BSC t per BSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 129


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

ZA9511:Number of none Packet -


Downlink Assignment
Assignments on Capability
PACCH per BSC Measuremen
t per BSC

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

5.3.4 Throughput Performance Analysis Report

PDCH Throughput Report

Report Type
Simple Report

NE Type
BSC6900GSM, BSC6000

Object Type
GCell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 130


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

PDCH Average Throughput none Uplink ([L9006:Number of Valid


Through of Uplink GPRS GPRS RLC Uplink RLC Data Blocks
put RLC per PDCH Data Using CS1]*{23}+
(kbps) Transfer [L9007:Number of Valid
Capability Uplink RLC Data Blocks
Measuremen Using CS2]*{34}+
t [L9008:Number of Valid
Uplink RLC Data Blocks
Using CS3]*{40}+
[L9009:Number of Valid
Uplink RLC Data Blocks
Using CS4]*{54})*{8}/
({1024}*[L9001:Total
Number of Uplink GPRS RLC
Data Blocks]*{20}/{1000})

Average Throughput none Downlink ([L9106:Total Number of


of Downlink GPRS GPRS RLC Valid RLC Downlink Data
RLC per PDCH Data Blocks Using CS1]*{23}+
(kbps) Transfer [L9107:Total Number of Valid
Capability RLC Downlink Data Blocks
Measuremen Using CS2]*{34}+
t [L9108:Total Number of Valid
RLC Downlink Data Blocks
Using CS3]*{40}+
[L9109:Total Number of Valid
RLC Downlink Data Block
Using CS4]*{54})*{8}/
({1024}*[L9101:Total
Number of Downlink GPRS
RLC Data Blocks]*{20}/
{1000})

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 131


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Average Throughput none Uplink (([L9211:Total Number of


of Uplink EGPRS EGPRS RLC Valid Uplink EGPRS MCS1
RLC per PDCH Data RLC Data Blocks]*{22}+
(kbps) Transfer [L9212:Total Number of Valid
Capability Uplink EGPRS MCS2 RLC
Measuremen Data Blocks]*{28}+
t [L9213:Total Number of Valid
Uplink EGPRS MCS3 RLC
Data Blocks]*{37}+
[L9214:Total Number of Valid
Uplink EGPRS MCS4 RLC
Data Blocks]*{44}+
[L9215:Total Number of Valid
Uplink EGPRS MCS5 RLC
Data Blocks]*{56}+
[L9216:Total Number of Valid
Uplink EGPRS MCS6 RLC
Data Blocks]*{74}+
[L9217:Total Number of Valid
Uplink EGPRS MCS7 RLC
Data Blocks]*{56}+
[L9218:Total Number of Valid
Uplink EGPRS MCS8 RLC
Data Blocks]*{68}+
[L9219:Total Number of Valid
Uplink EGPRS MCS9 RLC
Data Blocks]*{74})*{8})/
(({1024}*([L9202:Total
Number of Uplink EGPRS
MCS1 RLC Data Blocks]+
[L9203:Total Number of
Uplink EGPRS MCS2 RLC
Data Blocks]+[L9204:Total
Number of Uplink EGPRS
MCS3 RLC Data Blocks]+
[L9205:Total Number of
Uplink EGPRS MCS4 RLC
Data Blocks]+[L9206:Total
Number of Uplink EGPRS
MCS5 RLC Data Blocks]+
[L9207:Total Number of
Uplink EGPRS MCS6 RLC
Data Blocks]+[L9208:Total
Number of Uplink EGPRS
MCS7 RLC Data Blocks]/{2}+
[L9209:Total Number of
Uplink EGPRS MCS8 RLC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 132


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Data Blocks]/{2}+
[L9210:Total Number of
Uplink EGPRS MCS9 RLC
Data Blocks]/{2})*{20}/
{1000}))

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 133


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Average Throughput none Uplink (([L9311:Total Number of


of Downlink EGPRS EGPRS RLC Valid Downlink EGPRS
RLC per PDCH Data MCS1 RLC Data Blocks]*
(kbps) Transfer {22}+[L9312:Total Number of
Capability Valid Downlink EGPRS
Measuremen MCS2 RLC Data Blocks]*
t {28}+[L9313:Total Number of
Valid Downlink EGPRS
MCS3 RLC Data Blocks]*
{37}+[L9314:Total Number of
Valid Downlink EGPRS
MCS4 RLC Data Blocks]*
{44}+[L9315:Total Number of
Valid Downlink EGPRS
MCS5 RLC Data Blocks]*
{56}+[L9316:Total Number of
Valid Downlink EGPRS
MCS6 RLC Data Blocks]*
{74}+[L9317:Total Number of
Valid Downlink EGPRS
MCS7 RLC Data Blocks]*
{56}+[L9318:Total Number of
Valid Downlink EGPRS
MCS8 RLC Data Blocks]*
{68}+[L9319:Total Number of
Valid Downlink EGPRS
MCS9 RLC Data Blocks]*
{74})*{8})/(({1024}*
([L9302:Total Number of
Downlink EGPRS MCS1 RLC
Data Blocks]+[L9303:Total
Number of Downlink EGPRS
MCS2 RLC Data Blocks]+
[L9304:Total Number of
Downlink EGPRS MCS3 RLC
Data Blocks]+[L9305:Total
Number of Downlink EGPRS
MCS4 RLC Data Blocks]+
[L9306:Total Number of
Downlink EGPRS MCS5 RLC
Data Blocks]+[L9307:Total
Number of Downlink EGPRS
MCS6 RLC data blocks]+
[L9308:Total Number of
Downlink EGPRS MCS7 RLC
Data Blocks]/{2}+
[L9309:Total Number of

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 134


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Downlink EGPRS MCS8 RLC


Data Blocks]/{2}+
[L9310:Total Number of
Downlink EGPRS MCS9 RLC
Data Blocks]/{2})*{20}/
{1000}))

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Subscriber Throughput Report

Report Type
Simple Report

NE Type
BSC6900GSM, BSC6000

Object Type
GCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Subscrib AL9529:Downlink kbit/s Downlink -


er Throughput of GPRS LLC Data
Through Users LLC PDU Transfer
put Capability
Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 135


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

AL9530:Downlink kbit/s Downlink -


Throughput of LLC Data
EGPRS Users LLC Transfer
PDU Capability
Measuremen
t

AL9425:Uplink kbit/s Uplink LLC -


Throughput of GPRS Data
Users LLC PDU Transfer
Capability
Measuremen
t

AL9426:Uplink kbit/s Uplink LLC -


Throughput of Data
EGPRS Users LLC Transfer
PDU Capability
Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

5.4 VAMOS Performance Report

5.4.1 Handset Type Influence to VAMOS analysis Report

Report Type
Simple Report

NE Type
BSC6900GSM, BSC6000

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 136


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Object Type
GCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Handset VAMOS Traffic % Channel [R3501:Mean Number of Busy


Type Valume Ratio[%] State Channels (VAMOS TCHH)]/
Influence Measuremen ([K3014:Traffic Volume on
to t per Cell TCH]*{2})
VAMOS
analysis Calls Supporting % Measuremen [A03628:Number of Calls
SAIC Ratio[%] t of MS Originated or Terminated by
Capability MSs Supporting SAIC]/
per Cell [A03640:Number of Calls]

Calls Supporting % Measuremen [A03641:Number of


VAMOS-1 Ratio[%] t of MS VAMOS-1 Calls]/
Capability [A03640:Number of Calls]
per Cell

Calls Supporting % Measuremen [A03642:Number of


VAMOS-2 Ratio[%] t of MS VAMOS-2 Calls]/
Capability [A03640:Number of Calls]
per Cell

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

5.4.2 VAMOS Call Drop Ratio Analysis Report

Report Type
Simple Report

NE Type
BSC6900GSM, BSC6000

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 137


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Object Type
GCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

VAMOS VAMOS CALL % VAMOS [H3061:Number of VAMOS


Call Drop Ratio Call Call Drops (Demultiplexing
Drop (Demultiplexing) Measuremen Handover)]/
Ratio t for Cell ((([A3100M:Number of
Analysis VAMOS Channel
Multiplexing Commands
(Assignment)]-
[A3100N:Number of Failed
VAMOS Channel
Multiplexing Attempts
(Assignment)])+
([H3052:Number of VAMOS
Channel Multiplexing
Commands (Intra-Cell
Handover)]-[H3053:Number
of Failed VAMOS Channel
Multiplexing Attempts (Intra-
Cell Handover)]))*{2})*{100}

VAMOS CALL % VAMOS [H3062:Number of VAMOS


Drop Ratio(Others) Call Call Drops (Other Handover)]/
Measuremen ((([A3100M:Number of
t for Cell VAMOS Channel
Multiplexing Commands
(Assignment)]-
[A3100N:Number of Failed
VAMOS Channel
Multiplexing Attempts
(Assignment)])+
([H3052:Number of VAMOS
Channel Multiplexing
Commands (Intra-Cell
Handover)]-[H3053:Number
of Failed VAMOS Channel
Multiplexing Attempts (Intra-
Cell Handover)]))*{2})*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 138


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VAMOS CALL % VAMOS [H3063:Number of VAMOS


Drop Ratio(Stable Call Call Drops (Stable State)]/
State) Measuremen ((([A3100M:Number of
t for Cell VAMOS Channel
Multiplexing Commands
(Assignment)]-
[A3100N:Number of Failed
VAMOS Channel
Multiplexing Attempts
(Assignment)])+
([H3052:Number of VAMOS
Channel Multiplexing
Commands (Intra-Cell
Handover)]-[H3053:Number
of Failed VAMOS Channel
Multiplexing Attempts (Intra-
Cell Handover)]))*{2})*{100}

VAMOS CALL % VAMOS ([H3061:Number of VAMOS


Drop Times Ratio Call Call Drops (Demultiplexing
Measuremen Handover)]+[H3062:Number
t for Cell of VAMOS Call Drops (Other
Handover)]+([H3063:Number
of VAMOS Call Drops (Stable
State)]/((([A3100M:Number
of VAMOS Channel
Multiplexing Commands
(Assignment)]-
[A3100N:Number of Failed
VAMOS Channel
Multiplexing Attempts
(Assignment)])+
([H3052:Number of VAMOS
Channel Multiplexing
Commands (Intra-Cell
Handover)]-[H3053:Number
of Failed VAMOS Channel
Multiplexing Attempts (Intra-
Cell Handover)]))*{2})*
{100}))/([CM33:Call Drops on
Traffic Channel]*{2})*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 139


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

5.4.3 VAMOS Influence to Network Total Performance Analysis


Report

Report Type
Simple Report

NE Type
BSC6900GSM, BSC6000

Object Type
GCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

VAMOS K3014:Traffic Erl KPI -


Influence Volume on TCH Measuremen
to t per Cell
Network
Total VAMOS Traffic % Channel [R3501:Mean Number of Busy
Performa Valume Ratio[%] State Channels (VAMOS TCHH)]/
nce Measuremen ([K3014:Traffic Volume on
Analysis t per Cell TCH]*{2})

K3045:Congestion % KPI -
Rate on TCH (All Measuremen
Channels Busy) t per Cell

ZTR304:Call Drop % Call Drop -


Rate on TCH per cell Measuremen
(including t per Cell
Handover)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 140


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

RH303C:Intra-BSC % Intra-cell -
Radio Handover Handover
Success Rate Measuremen
t per Cell

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

5.4.4 VAMOS Radio Handover Success Ratio Analysis Report

Report Type
Simple Report

NE Type
BSC6900GSM, BSC6000

Object Type
GCell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 141


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

VAMOS Successful Ratio % VAMOS [H3052:Number of VAMOS


Radio Radio Handover by Call Channel Multiplexing
Handove VAMOS Channel Measuremen Commands (Intra-Cell
r Success Multiplexing t for Cell Handover)]/([H3052:Number
Ratio of VAMOS Channel
Analysis Multiplexing Commands
(Intra-Cell Handover)]-
[H3053:Number of Failed
VAMOS Channel
Multiplexing Attempts (Intra-
Cell Handover)])*{100}

Successful Ratio % VAMOS [H3056:Number of VAMOS


Radio Handover by Call Call Handover Commands
VAMOS Channel Measuremen (Demultiplexing)]/
Demultiplexing t for Cell ([H3056:Number of VAMOS
Call Handover Commands
(Demultiplexing)]-
[H3059:Number of VAMOS
Call Handover Commands
(Others)])*{100}

Successful Ratio % VAMOS [H3059:Number of VAMOS


Radio Handover Call Call Handover Commands
(Other VAMOS Measuremen (Others)]/([H3060:Number of
Call) t for Cell Failed VAMOS Call Handover
Attempts (Others)]-
[H3060:Number of Failed
VAMOS Call Handover
Attempts (Others)])*{100}

RH303C:Intra-BSC % Intra-cell -
Radio Handover Handover
Success Rate Measuremen
t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 142


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Unsuccessful Vamos % VAMOS ([H3053:Number of Failed


Call Handovers Ratio Call VAMOS Channel
Measuremen Multiplexing Attempts (Intra-
t for Cell Cell Handover)]+
[H3059:Number of VAMOS
Call Handover Commands
(Others)]+[H3060:Number of
Failed VAMOS Call Handover
Attempts (Others)])/
(([CH301:Internal Intra-Cell
Handover Commands]-
[CH303:Successful Internal
Intra-Cell Handovers])+
([CH321:Number of Incoming
Internal Inter-Cell Handover
Responses]-[CH323:Number
of Successful Incoming
Internal Inter-Cell
Handovers]))*{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

5.5 BSC KPI Overview Report


Report Type
Simple Report

NE Type
BSC6900GSM, BSC6000

Object Type
GBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 143


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

CS RA303G:Success % Immediate -
Accessab Rate of Immediate Assignment
lity KPI Assignments Measuremen
t per Cell

RR370:Congestion % Channel -
Rate on SDCCH per Assignment
CELL (due to Busy) Failure
Measuremen
t per Cell

ZTR104C:Call Drop % Call Drop -


Rate on SDCCH Measuremen
t per Cell

Assignment Success none Assignment [CA313:Successful


Rate Measuremen Assignments]/
t per Cell [CA310:Assignment Requests]
*{100}

K3041:TCH % KPI -
Congestion Rate Measuremen
(Overflow) t per Cell

K3043:TCH Seizure % KPI -


Success Rate Measuremen
t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 144


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Success Rate of Call none Assignment ([CA313:Successful


Establishment(V2) Measuremen Assignments]-
t per Cell ([A3100K:Assignment
Requests (Signaling Channel)
(SDCCH)]+[A3100A:Assign-
ment Requests (Signaling
Channel) (TCH)]-
[A312S:Failed Assignments
(Signaling Channel)]+
[CA310A:Assignment
Requests (TCH Assigned
Repeatedly over A Interface)]-
[CA312A:Failed Assignments
(TCH Assigned Repeatedly
over A Interface)]))/
([A3039J:SDCCH Seizures for
Speech Service]+
[A301F:TCHF Seizures for
Speech Service]+
[A301HH:TCHH Seizures for
Speech Service])*{100}

BSS Call none Immediate ((([CA303J:Call Setup


Establishment Assignment Indications (Circuit Service)])*
Success Rate Measuremen {100}/([CA300J:Channel
t per Cell Requests (Circuit Service)]))/
{100})*((([CA313:Successful
Assignments])*{100}/
([CA310:Assignment
Requests]))/{100})*({1}-
((([CM30:Call Drops on
SDCCH])*{100}/
([K3003:Successful SDCCH
Seizures]))/{100}))*{100}

OVERLOAD rate of none Flow Control ([L3188C:MSG CCCH LOAD


paging Measuremen IND (PCH) Messages Sent on
t per Cell Abis Interface (CS Service)]+
[L3188D:MSG CCCH LOAD
IND (PCH) Messages Sent on
Abis Interface (PS Service)])/
([A330:Delivered Paging
Messages for CS Service]+
[A331:Delivered Paging
Messages for PS Service])*
{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 145


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

CS ZTR304:Call Drop % Call Drop -


Retainabi Rate on TCH per cell Measuremen
lity KPI (including t per Cell
Handover)

ZTR304A:Call Drop % Call Drop -


Rate on TCH per cell Measuremen
(Excluding t per Cell
Handover)

Traffic Call Drop none KPI {60}*[K3014:Traffic Volume


Ratio per cell(V2) Measuremen on TCH]/[CM33:Call Drops on
t per Cell Traffic Channel]*{100}

RM333:Radio Drop % Call Drop -


Rate of TCH Measuremen
t per Cell

RH333:Handover % Intra-cell -
Drop Rate of TCH Handover
Measuremen
t per Cell

CS RH303:Handover % Incoming -
Mobility Success Rate Internal
KPI Inter-Cell
Handover
Measuremen
t per Cell

RH303A:Success % Incoming -
Rate of Radio Internal
Handover Inter-Cell
Handover
Measuremen
t per Cell

RH303B:Intra-BSC % Intra-cell -
Handover Success Handover
Rate Measuremen
t per Cell

RH303C:Intra-BSC % Intra-cell -
Radio Handover Handover
Success Rate Measuremen
t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 146


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

TH343:Success Rate % Incoming -


of Incoming External External
Inter-Cell Handovers Inter-Cell
Handover
Measuremen
t per Cell

RH303D:Success % Incoming -
Rate of Incoming External
External Inter-Cell Inter-Cell
Radio Handovers Handover
Measuremen
t per Cell

TH333:Success Rate % Outgoing -


of Outgoing External External
Inter-Cell Handovers Inter-Cell
Handover
Measuremen
t per Cell

RH303E:Success % Outgoing -
Rate of External External
Outgoing Cell Radio Inter-Cell
Handovers Handover
Measuremen
t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 147


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Success Rate of none Incoming (([RH3031G:Incoming


Dual-Band Internal Internal Inter-Cell Handover
Handovers (900M/ Inter-Cell Requests
850M-1800M/ Handover (900/850/810-1800/1900)]+
1900M)(V2) Measuremen [RH3033G:Incoming External
t per Cell Inter-Cell Handover Requests
(900/850/810-1800/1900)]+
[RH3035G:Outgoing External
Inter-Cell Handover Requests
(900/850/810-1800/1900)])-
([RH3031F:Failed Incoming
Internal Inter-Cell Handovers
(900/850/810-1800/1900)]+
[RH3033F:Failed Incoming
External Inter-Cell Handovers
(900/850/810-1800/1900)]+
[RH3035F:Failed Outgoing
External Inter-Cell Handovers
(900/850/810-1800/1900)]))/
([RH3031G:Incoming Internal
Inter-Cell Handover Requests
(900/850/810-1800/1900)]+
[RH3033G:Incoming External
Inter-Cell Handover Requests
(900/850/810-1800/1900)]+
[RH3035G:Outgoing External
Inter-Cell Handover Requests
(900/850/810-1800/1900)])*
{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 148


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Success Rate of none Incoming (([RH3032G:Incoming


Dual-Band Internal Internal Inter-Cell Handover
Handovers (1800M/ Inter-Cell Requests
1900M-900M/ Handover (1800/1900-900/850/810)]+
850M)(V2) Measuremen [RH3034G:Incoming External
t per Cell Inter-Cell Handover Requests
(1800/1900-900/850/810)]+
[RH3036G:Outgoing External
Inter-Cell Handover Requests
(1800/1900-900/850/810)])-
([RH3032F:Failed Incoming
Internal Inter-Cell Handovers
(1800/1900-900/850/810)]+
[RH3034F:Failed Incoming
External Inter-Cell Handovers
(1800/1900-900/850/810)]+
[RH3036F:Failed Outgoing
External Inter-Cell Handovers
(1800/1900-900/850/810)]))/
([RH3032G:Incoming Internal
Inter-Cell Handover Requests
(1800/1900-900/850/810)]+
[RH3034G:Incoming External
Inter-Cell Handover Requests
(1800/1900-900/850/810)]+
[RH3036G:Outgoing External
Inter-Cell Handover Requests
(1800/1900-900/850/810)])*
{100}

CS Traffic Volume on none KPI [K3014:Traffic Volume on


Resource TCH(V2) Measuremen TCH]
Usage t per Cell
Ratio
KPI TCHH Traffic none KPI [K3034:TCHH Traffic
Volume(V2) Measuremen Volume]
t per Cell

Traffic Volume on none KPI [K3004:Traffic Volume on


SDCCH(V2) Measuremen SDCCH]
t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 149


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

TCH Availability none Channel ([CR3027:Mean Number of


(V2) Configuratio Available Channels (TCHF)]+
n [CR3028:Mean Number of
Measuremen Available Channels (TCHH)])/
t per Cell ([CR3017:Mean Number of
Dynamically Configured
Channels (TCHF)]+
[CR3018:Mean Number of
Dynamically Configured
Channels (TCHH)])*{100}

SDCCH Availability none Channel [CR3020:Mean Number of


(V2) Configuratio Available Channels
n (SDCCH)]/[CR3010:Mean
Measuremen Number of Dynamically
t per Cell Configured Channels
(SDCCH)]*{100}

RK3255:TRX % KPI -
Usability Measuremen
t per Cell

PS Successful Uplink none Packet [A9502:Number of Successful


Accessab Assignment Rate Assignment Uplink Assignments]/
lity KPI Capability [A9501:Number of Uplink
Measuremen Assignments]*{100}
t

Successful Downlink none Packet [A9508:Number of Successful


Assignment Rate Assignment Downlink Assignments]/
Capability [A9507:Number of Downlink
Measuremen Assignments]*{100}
t

Uplink TBF none Uplink ([A9002:Number of Successful


Establishment GPRS TBF Uplink GPRS TBF
Success Rate Establish and Establishments]+
Release [A9202:Number of Successful
Capability Uplink EGPRS TBF
Measuremen Establishments])/
t ([A9001:Number of Uplink
GPRS TBF Establishment
Attempts]+[A9201:Number of
Uplink EGPRS TBF
Establishment Attempts])*
{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 150


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Downlink TBF none Downlink ([A9102:Number of Successful


Establishment GPRS TBF Downlink GPRS TBF
Success Rate Establish and Establishments]+
Release [A9302:Number of Successful
Capability Downlink EGPRS TBF
Measuremen Establishments])/
t ([A9101:Number of Downlink
GPRS TBF Establishment
Attempts]+[A9301:Number of
Downlink EGPRS TBF
Establishment Attempts])*
{100}

Uplink EGPRS none Uplink [A9202:Number of Successful


Establishment EGPRS TBF Uplink EGPRS TBF
Success Rate Establish and Establishments]/
Release [A9201:Number of Uplink
Capability EGPRS TBF Establishment
Measuremen Attempts]*{100}
t

Downlink EGPRS none Downlink [A9302:Number of Successful


Establishment EGPRS TBF Downlink EGPRS TBF
Success Rate Establish and Establishments]/
Release [A9301:Number of Downlink
Capability EGPRS TBF Establishment
Measuremen Attempts]*{100}
t

Uplink TBF none Uplink ([A9003:Number of Failed


Congestion Rate GPRS TBF Uplink GPRS TBF
Establish and Establishments due to No
Release Channel]+[A9203:Number of
Capability Failed Uplink EGPRS TBF
Measuremen Establishments due to No
t Channel])/([A9001:Number of
Uplink GPRS TBF
Establishment Attempts]+
[A9201:Number of Uplink
EGPRS TBF Establishment
Attempts])*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 151


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Downlink TBF none Downlink ([A9103:Number of Failed


Congestion Rate GPRS TBF Downlink GPRS TBF
Establish and Establishments due to No
Release Channel]+[A9303:Number of
Capability Failed Downlink EGPRS TBF
Measuremen Establishments due to No
t Channel])/([A9101:Number of
Downlink GPRS TBF
Establishment Attempts]+
[A9301:Number of Downlink
EGPRS TBF Establishment
Attempts])*{100}

Uplink EGPRS TBF none Uplink [A9203:Number of Failed


Congestion Rate EGPRS TBF Uplink EGPRS TBF
Establish and Establishments due to No
Release Channel]/[A9201:Number of
Capability Uplink EGPRS TBF
Measuremen Establishment Attempts]*
t {100}

Downlink EGPRS none Downlink [A9303:Number of Failed


TBF Congestion EGPRS TBF Downlink EGPRS TBF
Rate Establish and Establishments due to No
Release Channel]/[A9301:Number of
Capability Downlink EGPRS TBF
Measuremen Establishment Attempts]*
t {100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 152


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

PS Uplink TBF Drop none Uplink ([A9006:Number of Uplink


Retainabi Rate(%) GPRS TBF GPRS TBF Abnormal Releases
lity KPI Establish and due to N3101 Overflow (MS
Release No Response)]+
Capability [A9007:Number of Uplink
Measuremen GPRS TBF Abnormal Releases
t due to N3103 Overflow (MS
No Response)]+
[A9206:Number of Uplink
EGPRS TBF Abnormal
Releases due to N3101
Overflow (MS No Response)]+
[A9207:Number of Uplink
EGPRS TBF Abnormal
Releases due to N3103
Overflow (MS No
Response)])/([A9002:Number
of Successful Uplink GPRS
TBF Establishments]+
[A9202:Number of Successful
Uplink EGPRS TBF
Establishments])*{100}

Downlink TBF Drop none Downlink ([A9118:Number of Downlink


Rate(%) GPRS TBF GPRS Intermit Transfers]+
Establish and [A9318:Number of Downlink
Release EGPRS Intermit Transfers])/
Capability ([A9102:Number of Successful
Measuremen Downlink GPRS TBF
t Establishments]+
[A9302:Number of Successful
Downlink EGPRS TBF
Establishments])*{100}

Uplink EGPRS TBF none Uplink ([A9206:Number of Uplink


Drop Rate EGPRS TBF EGPRS TBF Abnormal
Establish and Releases due to N3101
Release Overflow (MS No Response)]+
Capability [A9207:Number of Uplink
Measuremen EGPRS TBF Abnormal
t Releases due to N3103
Overflow (MS No
Response)])/[A9202:Number
of Successful Uplink EGPRS
TBF Establishments]*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 153


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Downlink EGPRS none Downlink [A9318:Number of Downlink


TBF Drop Rate EGPRS TBF EGPRS Intermit Transfers]/
Establish and [A9302:Number of Successful
Release Downlink EGPRS TBF
Capability Establishments]*{100}
Measuremen
t

PS Retransmission Rate none Uplink ({1}-(([L9006:Number of


Transmis of Uplink GPRS GPRS RLC Valid Uplink RLC Data Blocks
sion RLC Data Blocks(%) Data Using CS1]+[L9007:Number
Performa Transfer of Valid Uplink RLC Data
nce KPI Capability Blocks Using CS2]+
Measuremen [L9008:Number of Valid
t Uplink RLC Data Blocks
Using CS3]+[L9009:Number
of Valid Uplink RLC Data
Blocks Using CS4])/
[L9001:Total Number of
Uplink GPRS RLC Data
Blocks]))*{100}

Retransmission Rate none Downlink ({1}-(([L9106:Total Number


of Downlink GPRS GPRS RLC of Valid RLC Downlink Data
RLC Data Blocks(%) Data Blocks Using CS1]+
Transfer [L9107:Total Number of Valid
Capability RLC Downlink Data Blocks
Measuremen Using CS2]+[L9108:Total
t Number of Valid RLC
Downlink Data Blocks Using
CS3]+[L9109:Total Number of
Valid RLC Downlink Data
Block Using CS4])/
[L9101:Total Number of
Downlink GPRS RLC Data
Blocks]))*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 154


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Retransmission Rate none Uplink ({1}-(([L9211:Total Number


of Uplink EGPRS EGPRS RLC of Valid Uplink EGPRS MCS1
RLC Data Blocks(%) Data RLC Data Blocks]+
Transfer [L9212:Total Number of Valid
Capability Uplink EGPRS MCS2 RLC
Measuremen Data Blocks]+[L9213:Total
t Number of Valid Uplink
EGPRS MCS3 RLC Data
Blocks]+[L9214:Total
Number of Valid Uplink
EGPRS MCS4 RLC Data
Blocks]+[L9215:Total
Number of Valid Uplink
EGPRS MCS5 RLC Data
Blocks]+[L9216:Total
Number of Valid Uplink
EGPRS MCS6 RLC Data
Blocks]+[L9217:Total
Number of Valid Uplink
EGPRS MCS7 RLC Data
Blocks]+[L9218:Total
Number of Valid Uplink
EGPRS MCS8 RLC Data
Blocks]+[L9219:Total
Number of Valid Uplink
EGPRS MCS9 RLC Data
Blocks])/[L9201:Total
Number of Uplink EGPRS
RLC Data Blocks]))*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 155


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Retransmission Rate none Downlink ({1}-(([L9311:Total Number


of Downlink EGPRS EGPRS RLC of Valid Downlink EGPRS
RLC Data Blocks(%) Data MCS1 RLC Data Blocks]+
Transfer [L9312:Total Number of Valid
Capability Downlink EGPRS MCS2 RLC
Measuremen Data Blocks]+[L9313:Total
t Number of Valid Downlink
EGPRS MCS3 RLC Data
Blocks]+[L9314:Total
Number of Valid Downlink
EGPRS MCS4 RLC Data
Blocks]+[L9315:Total
Number of Valid Downlink
EGPRS MCS5 RLC Data
Blocks]+[L9316:Total
Number of Valid Downlink
EGPRS MCS6 RLC Data
Blocks]+[L9317:Total
Number of Valid Downlink
EGPRS MCS7 RLC Data
Blocks]+[L9318:Total
Number of Valid Downlink
EGPRS MCS8 RLC Data
Blocks]+[L9319:Total
Number of Valid Downlink
EGPRS MCS9 RLC Data
Blocks])/[L9301:Total
Number of Downlink EGPRS
RLC Data Blocks]))*{100}

Rate of Uplink GPRS none Uplink ([L9008:Number of Valid


RLC Coding Scheme GPRS RLC Uplink RLC Data Blocks
with CS3&CS4(%) Data Using CS3]+[L9009:Number
Transfer of Valid Uplink RLC Data
Capability Blocks Using CS4])/
Measuremen ([L9006:Number of Valid
t Uplink RLC Data Blocks
Using CS1]+[L9007:Number
of Valid Uplink RLC Data
Blocks Using CS2]+
[L9008:Number of Valid
Uplink RLC Data Blocks
Using CS3]+[L9009:Number
of Valid Uplink RLC Data
Blocks Using CS4])*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 156


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Rate of Downlink none Downlink ([L9108:Total Number of


GPRS RLC Coding GPRS RLC Valid RLC Downlink Data
Scheme with Data Blocks Using CS3]+
CS3&CS4(%) Transfer [L9109:Total Number of Valid
Capability RLC Downlink Data Block
Measuremen Using CS4])/([L9106:Total
t Number of Valid RLC
Downlink Data Blocks Using
CS1]+[L9107:Total Number of
Valid RLC Downlink Data
Blocks Using CS2]+
[L9108:Total Number of Valid
RLC Downlink Data Blocks
Using CS3]+[L9109:Total
Number of Valid RLC
Downlink Data Block Using
CS4])*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 157


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Rate of Uplink none Uplink ([L9217:Total Number of


EGPRS RLC Coding EGPRS RLC Valid Uplink EGPRS MCS7
Scheme with Data RLC Data Blocks]+
MCS7&MCS8&MC Transfer [L9218:Total Number of Valid
S9(%) Capability Uplink EGPRS MCS8 RLC
Measuremen Data Blocks]+[L9219:Total
t Number of Valid Uplink
EGPRS MCS9 RLC Data
Blocks])/([L9211:Total
Number of Valid Uplink
EGPRS MCS1 RLC Data
Blocks]+[L9212:Total
Number of Valid Uplink
EGPRS MCS2 RLC Data
Blocks]+[L9213:Total
Number of Valid Uplink
EGPRS MCS3 RLC Data
Blocks]+[L9214:Total
Number of Valid Uplink
EGPRS MCS4 RLC Data
Blocks]+[L9215:Total
Number of Valid Uplink
EGPRS MCS5 RLC Data
Blocks]+[L9216:Total
Number of Valid Uplink
EGPRS MCS6 RLC Data
Blocks]+[L9217:Total
Number of Valid Uplink
EGPRS MCS7 RLC Data
Blocks]+[L9218:Total
Number of Valid Uplink
EGPRS MCS8 RLC Data
Blocks]+[L9219:Total
Number of Valid Uplink
EGPRS MCS9 RLC Data
Blocks])*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 158


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Rate of Downlink none Downlink ([L9317:Total Number of


EGPRS RLC Coding EGPRS RLC Valid Downlink EGPRS
Scheme with Data MCS7 RLC Data Blocks]+
MCS7&MCS8&MC Transfer [L9318:Total Number of Valid
S9(%) Capability Downlink EGPRS MCS8 RLC
Measuremen Data Blocks]+[L9319:Total
t Number of Valid Downlink
EGPRS MCS9 RLC Data
Blocks])/([L9311:Total
Number of Valid Downlink
EGPRS MCS1 RLC Data
Blocks]+[L9312:Total
Number of Valid Downlink
EGPRS MCS2 RLC Data
Blocks]+[L9313:Total
Number of Valid Downlink
EGPRS MCS3 RLC Data
Blocks]+[L9314:Total
Number of Valid Downlink
EGPRS MCS4 RLC Data
Blocks]+[L9315:Total
Number of Valid Downlink
EGPRS MCS5 RLC Data
Blocks]+[L9316:Total
Number of Valid Downlink
EGPRS MCS6 RLC Data
Blocks]+[L9317:Total
Number of Valid Downlink
EGPRS MCS7 RLC Data
Blocks]+[L9318:Total
Number of Valid Downlink
EGPRS MCS8 RLC Data
Blocks]+[L9319:Total
Number of Valid Downlink
EGPRS MCS9 RLC Data
Blocks])*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 159


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Average Throughput none Uplink ([L9006:Number of Valid


of Uplink GPRS GPRS RLC Uplink RLC Data Blocks
RLC per PDCH Data Using CS1]*{23}+
(kbps) Transfer [L9007:Number of Valid
Capability Uplink RLC Data Blocks
Measuremen Using CS2]*{34}+
t [L9008:Number of Valid
Uplink RLC Data Blocks
Using CS3]*{40}+
[L9009:Number of Valid
Uplink RLC Data Blocks
Using CS4]*{54})*{8}/
({1024}*[L9001:Total
Number of Uplink GPRS RLC
Data Blocks]*{20}/{1000})

Average Throughput none Downlink ([L9106:Total Number of


of Downlink GPRS GPRS RLC Valid RLC Downlink Data
RLC per PDCH Data Blocks Using CS1]*{23}+
(kbps) Transfer [L9107:Total Number of Valid
Capability RLC Downlink Data Blocks
Measuremen Using CS2]*{34}+
t [L9108:Total Number of Valid
RLC Downlink Data Blocks
Using CS3]*{40}+
[L9109:Total Number of Valid
RLC Downlink Data Block
Using CS4]*{54})*{8}/
({1024}*[L9101:Total
Number of Downlink GPRS
RLC Data Blocks]*{20}/
{1000})

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 160


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Average Throughput none Uplink (([L9211:Total Number of


of Uplink EGPRS EGPRS RLC Valid Uplink EGPRS MCS1
RLC per PDCH Data RLC Data Blocks]*{22}+
(kbps) Transfer [L9212:Total Number of Valid
Capability Uplink EGPRS MCS2 RLC
Measuremen Data Blocks]*{28}+
t [L9213:Total Number of Valid
Uplink EGPRS MCS3 RLC
Data Blocks]*{37}+
[L9214:Total Number of Valid
Uplink EGPRS MCS4 RLC
Data Blocks]*{44}+
[L9215:Total Number of Valid
Uplink EGPRS MCS5 RLC
Data Blocks]*{56}+
[L9216:Total Number of Valid
Uplink EGPRS MCS6 RLC
Data Blocks]*{74}+
[L9217:Total Number of Valid
Uplink EGPRS MCS7 RLC
Data Blocks]*{56}+
[L9218:Total Number of Valid
Uplink EGPRS MCS8 RLC
Data Blocks]*{68}+
[L9219:Total Number of Valid
Uplink EGPRS MCS9 RLC
Data Blocks]*{74})*{8})/
(({1024}*([L9202:Total
Number of Uplink EGPRS
MCS1 RLC Data Blocks]+
[L9203:Total Number of
Uplink EGPRS MCS2 RLC
Data Blocks]+[L9204:Total
Number of Uplink EGPRS
MCS3 RLC Data Blocks]+
[L9205:Total Number of
Uplink EGPRS MCS4 RLC
Data Blocks]+[L9206:Total
Number of Uplink EGPRS
MCS5 RLC Data Blocks]+
[L9207:Total Number of
Uplink EGPRS MCS6 RLC
Data Blocks]+[L9208:Total
Number of Uplink EGPRS
MCS7 RLC Data Blocks]/{2}+
[L9209:Total Number of
Uplink EGPRS MCS8 RLC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 161


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Data Blocks]/{2}+
[L9210:Total Number of
Uplink EGPRS MCS9 RLC
Data Blocks]/{2})*{20}/
{1000}))

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 162


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Average Throughput none Uplink (([L9311:Total Number of


of Downlink EGPRS EGPRS RLC Valid Downlink EGPRS
RLC per PDCH Data MCS1 RLC Data Blocks]*
(kbps) Transfer {22}+[L9312:Total Number of
Capability Valid Downlink EGPRS
Measuremen MCS2 RLC Data Blocks]*
t {28}+[L9313:Total Number of
Valid Downlink EGPRS
MCS3 RLC Data Blocks]*
{37}+[L9314:Total Number of
Valid Downlink EGPRS
MCS4 RLC Data Blocks]*
{44}+[L9315:Total Number of
Valid Downlink EGPRS
MCS5 RLC Data Blocks]*
{56}+[L9316:Total Number of
Valid Downlink EGPRS
MCS6 RLC Data Blocks]*
{74}+[L9317:Total Number of
Valid Downlink EGPRS
MCS7 RLC Data Blocks]*
{56}+[L9318:Total Number of
Valid Downlink EGPRS
MCS8 RLC Data Blocks]*
{68}+[L9319:Total Number of
Valid Downlink EGPRS
MCS9 RLC Data Blocks]*
{74})*{8})/(({1024}*
([L9302:Total Number of
Downlink EGPRS MCS1 RLC
Data Blocks]+[L9303:Total
Number of Downlink EGPRS
MCS2 RLC Data Blocks]+
[L9304:Total Number of
Downlink EGPRS MCS3 RLC
Data Blocks]+[L9305:Total
Number of Downlink EGPRS
MCS4 RLC Data Blocks]+
[L9306:Total Number of
Downlink EGPRS MCS5 RLC
Data Blocks]+[L9307:Total
Number of Downlink EGPRS
MCS6 RLC data blocks]+
[L9308:Total Number of
Downlink EGPRS MCS7 RLC
Data Blocks]/{2}+
[L9309:Total Number of

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 163


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Downlink EGPRS MCS8 RLC


Data Blocks]/{2}+
[L9310:Total Number of
Downlink EGPRS MCS9 RLC
Data Blocks]/{2})*{20}/
{1000}))

Average Throughput none Uplink ([L9006:Number of Valid


of Uplink GPRS GPRS RLC Uplink RLC Data Blocks
RLC per Cell(kbps) Data Using CS1]*{23}+
Transfer [L9007:Number of Valid
Capability Uplink RLC Data Blocks
Measuremen Using CS2]*{34}+
t [L9008:Number of Valid
Uplink RLC Data Blocks
Using CS3]*{40}+
[L9009:Number of Valid
Uplink RLC Data Blocks
Using CS4]*{54})*{8}/
({1024}*[L9020:Total
Duration of Uplink GPRS
TBFs])

Average Throughput none Downlink ([L9106:Total Number of


of Downlink GPRS GPRS RLC Valid RLC Downlink Data
RLC per Cell(kbps) Data Blocks Using CS1]*{23}+
Transfer [L9107:Total Number of Valid
Capability RLC Downlink Data Blocks
Measuremen Using CS2]*{34}+
t [L9108:Total Number of Valid
RLC Downlink Data Blocks
Using CS3]*{40}+
[L9109:Total Number of Valid
RLC Downlink Data Block
Using CS4]*{54})*{8}/
({1024}*[L9121:Total
Duration of Downlink GPRS
TBFs])

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 164


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Average Throughput none Uplink ([L9211:Total Number of


of Uplink EGPRS EGPRS RLC Valid Uplink EGPRS MCS1
RLC per Cell(kbps) Data RLC Data Blocks]*{22}+
Transfer [L9212:Total Number of Valid
Capability Uplink EGPRS MCS2 RLC
Measuremen Data Blocks]*{28}+
t [L9213:Total Number of Valid
Uplink EGPRS MCS3 RLC
Data Blocks]*{37}+
[L9214:Total Number of Valid
Uplink EGPRS MCS4 RLC
Data Blocks]*{44}+
[L9215:Total Number of Valid
Uplink EGPRS MCS5 RLC
Data Blocks]*{56}+
[L9216:Total Number of Valid
Uplink EGPRS MCS6 RLC
Data Blocks]*{74}+
[L9217:Total Number of Valid
Uplink EGPRS MCS7 RLC
Data Blocks]*{56}+
[L9218:Total Number of Valid
Uplink EGPRS MCS8 RLC
Data Blocks]*{68}+
[L9219:Total Number of Valid
Uplink EGPRS MCS9 RLC
Data Blocks]*{74})*{8}/
({1024}*[L9235:Total
Duration of Uplink EGPRS
TBFs])

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 165


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Average Throughput none Downlink ([L9311:Total Number of


of Downlink EGPRS EGPRS RLC Valid Downlink EGPRS
RLC per Cell(kbps) Data MCS1 RLC Data Blocks]*
Transfer {22}+[L9312:Total Number of
Capability Valid Downlink EGPRS
Measuremen MCS2 RLC Data Blocks]*
t {28}+[L9313:Total Number of
Valid Downlink EGPRS
MCS3 RLC Data Blocks]*
{37}+[L9314:Total Number of
Valid Downlink EGPRS
MCS4 RLC Data Blocks]*
{44}+[L9315:Total Number of
Valid Downlink EGPRS
MCS5 RLC Data Blocks]*
{56}+[L9316:Total Number of
Valid Downlink EGPRS
MCS6 RLC Data Blocks]*
{74}+[L9317:Total Number of
Valid Downlink EGPRS
MCS7 RLC Data Blocks]*
{56}+[L9318:Total Number of
Valid Downlink EGPRS
MCS8 RLC Data Blocks]*
{68}+[L9319:Total Number of
Valid Downlink EGPRS
MCS9 RLC Data Blocks]*
{74})*{8}/({1024}*
[L9336:Total Duration of
Downlink EGPRS TBFs])

Average Throughput none Uplink LLC [L9422:Throughput of Uplink


of Uplink GPRS LLC Data GPRS Users LLC PDU]/
per User(kbps) Transfer ([L9421:Total Bytes of Uplink
Capability GPRS Users LLC PDUs]*{8}/
Measuremen {1024})
t

Average Throughput none Downlink [L9526:Throughput of


of Downlink GPRS LLC Data Downlink GPRS Users LLC
LLC per User(kbps) Transfer PDU]/([L9525:Total Bytes of
Capability Downlink GPRS Users LLC
Measuremen PDU]*{8}/{1024})
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 166


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Average Throughput none Uplink LLC [L9424:Throughput of Uplink


of Uplink EGPRS Data EGPRS Users LLC PDU]/
LLC per User(kbps) Transfer ([L9423:Total Bytes of Uplink
Capability EGPRS Users LLC PDUs]*
Measuremen {8}/{1024})
t

Average Throughput none Downlink [L9528:Throughput of


of Downlink EGPRS LLC Data Downlink EGPRS Users LLC
LLC per User(kbps) Transfer PDU]/([L9527:Total Bytes of
Capability Downlink EGPRS Users LLC
Measuremen PDU]*{8}/{1024})
t

PS Uplink PDTCH/ none Cell Radio [R9204:Number of RLC Data


Resource PACCH Utilization Channel Blocks Received on Uplink
Usage Rate Capability PDTCH/PACCH]/
Ratio Measuremen [R9206:Total Number of
KPI t Uplink PDTCH/PACCH
Blocks]*{100}

Downlink PDTCH/ none Cell Radio [R9205:Number of RLC Data


PACCH Utilization Channel Blocks Sent on Downlink
Rate Capability PDTCH/PACCH]/
Measuremen [R9207:Total Number of
t Downlink PDTCH/PACCH
Blocks]*{100}

PDCH Occupation none PDCH [AR9311:Average Number of


Rate Resource Occupied PDCHs]/
Capability [AR9303:Average Number of
Measuremen Available PDCHs]*{100}
t

BSC Reclaimed none PDCH [R9344:Number of Reclaimed


Dynamic PDCH Rate Resource Busy Dynamic PDCHs]/
Capability [R9343:Number of Reclaimed
Measuremen Dynamic PDCHs]*{100}
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 167


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

5.6 GSM BSC KPI Report


Report Type
Simple Report

NE Type
BSC6900GSM, BSC6000

Object Type
GCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

GSM RCA313:Assign- % Assignment -


BSC KPI ment Success Rate Measuremen
Report t per Cell

K3043:TCH Seizure % KPI -


Success Rate Measuremen
t per Cell

RA303G:Success % Immediate -
Rate of Immediate Assignment
Assignments Measuremen
t per Cell

RA301G:Success % Immediate -
Rate of Random Assignment
Access Measuremen
t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 168


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

TH323:Success Rate % Incoming -


of Incoming Internal Internal
Inter-Cell Handovers Inter-Cell
Handover
Measuremen
t per Cell

RH303:Handover % Incoming -
Success Rate Internal
Inter-Cell
Handover
Measuremen
t per Cell

RH303A:Success % Incoming -
Rate of Radio Internal
Handover Inter-Cell
Handover
Measuremen
t per Cell

TH303:Success Rate % Intra-cell -


of Internal Intra-Cell Handover
Handover Measuremen
t per Cell

ZTR104C:Call Drop % Call Drop -


Rate on SDCCH Measuremen
t per Cell

ZTR304A:Call Drop % Call Drop -


Rate on TCH per cell Measuremen
(Excluding t per Cell
Handover)

ZTR304:Call Drop % Call Drop -


Rate on TCH per cell Measuremen
(including t per Cell
Handover)

RR370:Congestion % Channel -
Rate on SDCCH per Assignment
CELL (due to Busy) Failure
Measuremen
t per Cell

K3041:TCH % KPI -
Congestion Rate Measuremen
(Overflow) t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 169


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

K3045:Congestion % KPI -
Rate on TCH (All Measuremen
Channels Busy) t per Cell

K3014:Traffic Erl KPI -


Volume on TCH Measuremen
t per Cell

K3004:Traffic Erl KPI -


Volume on SDCCH Measuremen
t per Cell

RR307:TCH % Channel -
Availability Configuratio
n
Measuremen
t per Cell

RR300:SDCCH % Channel -
Availability Configuratio
n
Measuremen
t per Cell

ZTR308:Traffic Call none Channel -


Drop Ratio per cell State
Measuremen
t per Cell

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

5.7 GSM Network Performance Monitoring Report


(Engineer)
Report Type
Combined Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 170


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Simple Report(s) List


l Accessibility Report
l Call Drop Cell Report
l Congestion Cell Report
l Extra Busy Cell Report
l Extra Idle Cell Report
l GSM BSC KPI Report
l Mobility Report
l Resource Utilization Report
l Retainability Report
l Worst Cell Report
l BSC KPI Overview Report

Accessibility Report
Null

NE Type
BSC6900GSM, BSC6000

Object Type
GCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Accessib RA303G:Success % Immediate -


ility Rate of Immediate Assignment
Report Assignments Measuremen
t per Cell

K3100:Immediate times KPI -


Assignment Measuremen
Requests t per Cell

A9503:Number of times Packet -


Uplink PS Immediate Assignment
Assignments Capability
Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 171


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

A9504:Number of times Packet -


Successful Uplink PS Assignment
Immediate Capability
Assignments Measuremen
t

A9509:Number of times Packet -


Downlink PS Assignment
Immediate Capability
Assignments Measuremen
t

A9510:Number of times Packet -


Successful Downlink Assignment
PS Immediate Capability
Assignments Measuremen
t

R3100A:Channel times Channel -


Assignment Assignment
Requests in Request
Immediate Measuremen
Assignment t per Cell
Procedure (SDCCH)

R3109A:Channel times Channel -


Assignment Assignment
Requests in Request
Immediate Measuremen
Assignment t per Cell
Procedure (TCH)

K3010A:TCH times KPI -


Seizure Requests Measuremen
(Traffic Channel) t per Cell

K3043:TCH Seizure % KPI -


Success Rate Measuremen
t per Cell

K3021:Failed TCH times KPI -


Seizures due to Busy Measuremen
TCH (Signaling t per Cell
Channel)

K3023:Successful times KPI -


TCH Seizures Measuremen
(Signaling Channel) t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 172


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

ZTR104C:Call Drop % Call Drop -


Rate on SDCCH Measuremen
t per Cell

Call Drop Cell Report


Null

NE Type
BSC6900GSM, BSC6000

Object Type
GCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Call ZTR304A:Call Drop % Call Drop -


Drop Rate on TCH per cell Measuremen
Cell (Excluding t per Cell
Report Handover)

ZTR304:Call Drop % Call Drop -


Rate on TCH per cell Measuremen
(including t per Cell
Handover)

Congestion Cell Report


Null

NE Type
BSC6900GSM, BSC6000

Object Type
GCell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 173


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Congesti K3045:Congestion % KPI -


on Cell Rate on TCH (All Measuremen
Report Channels Busy) t per Cell

Extra Busy Cell Report


Null

NE Type
BSC6900GSM, BSC6000

Object Type
GCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Extra R3550N:Traffic Erl Channel -


Busy Volume of Signaling State
Cell Channels (TCH) Measuremen
Report t per Cell

Extra Idle Cell Report


Null

NE Type
BSC6900GSM, BSC6000

Object Type
GCell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 174


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Extra R3550N:Traffic Erl Channel -


Idle Cell Volume of Signaling State
Report Channels (TCH) Measuremen
t per Cell

GSM BSC KPI Report


Null

NE Type
BSC6900GSM, BSC6000

Object Type
GCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

GSM RCA313:Assign- % Assignment -


BSC KPI ment Success Rate Measuremen
Report t per Cell

K3043:TCH Seizure % KPI -


Success Rate Measuremen
t per Cell

RA303G:Success % Immediate -
Rate of Immediate Assignment
Assignments Measuremen
t per Cell

RA301G:Success % Immediate -
Rate of Random Assignment
Access Measuremen
t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 175


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

TH323:Success Rate % Incoming -


of Incoming Internal Internal
Inter-Cell Handovers Inter-Cell
Handover
Measuremen
t per Cell

RH303:Handover % Incoming -
Success Rate Internal
Inter-Cell
Handover
Measuremen
t per Cell

RH303A:Success % Incoming -
Rate of Radio Internal
Handover Inter-Cell
Handover
Measuremen
t per Cell

TH303:Success Rate % Intra-cell -


of Internal Intra-Cell Handover
Handover Measuremen
t per Cell

ZTR104C:Call Drop % Call Drop -


Rate on SDCCH Measuremen
t per Cell

ZTR304A:Call Drop % Call Drop -


Rate on TCH per cell Measuremen
(Excluding t per Cell
Handover)

ZTR304:Call Drop % Call Drop -


Rate on TCH per cell Measuremen
(including t per Cell
Handover)

RR370:Congestion % Channel -
Rate on SDCCH per Assignment
CELL (due to Busy) Failure
Measuremen
t per Cell

K3041:TCH % KPI -
Congestion Rate Measuremen
(Overflow) t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 176


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

K3045:Congestion % KPI -
Rate on TCH (All Measuremen
Channels Busy) t per Cell

K3014:Traffic Erl KPI -


Volume on TCH Measuremen
t per Cell

K3004:Traffic Erl KPI -


Volume on SDCCH Measuremen
t per Cell

RR307:TCH % Channel -
Availability Configuratio
n
Measuremen
t per Cell

RR300:SDCCH % Channel -
Availability Configuratio
n
Measuremen
t per Cell

ZTR308:Traffic Call none Channel -


Drop Ratio per cell State
Measuremen
t per Cell

Mobility Report
Null

NE Type
BSC6900GSM, BSC6000

Object Type
GCell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 177


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Mobility RH303:Handover % Incoming -


Report Success Rate Internal
Inter-Cell
Handover
Measuremen
t per Cell

H3122C:Number of times Outgoing -


Unsuccessful Internal
Outgoing Internal Inter-Cell
Inter-Cell Handovers Handover
(Uplink Strength) Measuremen
t per Cell

H3122B:Number of times Outgoing -


Unsuccessful Internal
Outgoing Internal Inter-Cell
Inter-Cell Handovers Handover
(Downlink Quality) Measuremen
t per Cell

H3122A:Number of times Outgoing -


Unsuccessful Internal
Outgoing Internal Inter-Cell
Inter-Cell Handovers Handover
(Uplink Quality) Measuremen
t per Cell

H311B:Number of times Outgoing -


Outgoing Internal Internal
Inter-Cell Handover Inter-Cell
Commands Handover
(Downlink Quality) Measuremen
t per Cell

H310O:Number of times Outgoing -


Outgoing Internal Internal
Inter-Cell Handover Inter-Cell
Requests (MS Handover
Handover in the Measuremen
Overlaid Subcell t per Cell
Covered by the
Enhanced Dualband
Network)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 178


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

H310N:Number of times Outgoing -


Outgoing Internal Internal
Inter-Cell Handover Inter-Cell
Requests (Overlaid Handover
to Underlaid Subcell Measuremen
in Enhanced t per Cell
Dualband Network)

H310M:Number of times Outgoing -


Outgoing Internal Internal
Inter-Cell Handover Inter-Cell
Requests (Underlaid Handover
to Overlaid Subcell Measuremen
in Enhanced t per Cell
Dualband Network)

H310F:Number of times Outgoing -


Outgoing Internal Internal
Inter-Cell Handover Inter-Cell
Requests (Better Handover
Cell) Measuremen
t per Cell

H310G:Number of times Outgoing -


Outgoing Internal Internal
Inter-Cell Handover Inter-Cell
Requests (Load) Handover
Measuremen
t per Cell

H310H:Number of times Outgoing -


Outgoing Internal Internal
Inter-Cell Handover Inter-Cell
Requests (Rapid Handover
Level Drop) Measuremen
t per Cell

H3100Y:Number of times Outgoing -


Outgoing Internal Internal
Inter-Cell Handover Inter-Cell
Requests (SDCCH) Handover
(Excluding Directed Measuremen
Retry) t per Cell
(900/850/810-1800/
1900)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 179


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

CH370a:Number of times Outgoing -


Successful Outgoing Internal
Internal Inter-Cell Inter-Cell
Handovers During Handover
BSC Local Switch Measuremen
t per Cell

CH370b:Number of times Outgoing -


Successful Outgoing Internal
Internal Inter-Cell Inter-Cell
Handovers During Handover
BTS Local Switch Measuremen
t per Cell

CH312C:Number of times Outgoing -


Unsuccessful Internal
Outgoing Internal Inter-Cell
Inter-Cell Handovers Handover
(Timer Expired) Measuremen
t per Cell

Resource Utilization Report


Null

NE Type
BSC6900GSM, BSC6000

Object Type
GCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Resource RR307:TCH % Channel -


Utilizatio Availability Configuratio
n Report n
Measuremen
t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 180


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

K3015:Available numb KPI -


TCHs er Measuremen
t per Cell

K3005:Available numb KPI -


SDCCHs er Measuremen
t per Cell

K3006:Configured numb KPI -


SDCCHs er Measuremen
t per Cell

K3016:Configured numb KPI -


TCHs er Measuremen
t per Cell

RCA313:Assign- % Assignment -
ment Success Rate Measuremen
t per Cell

A3157A:Failed times Assignment -


Mode Modify Measuremen
Attempts (MOC) t per Cell
(TCHF)

A3157C:Failed times Assignment -


Mode Modify Measuremen
Attempts (MTC) t per Cell
(TCHF)

A3158A:Failed times Assignment -


Mode Modify Measuremen
Attempts (MOC) t per Cell
(TCHH)

A3158C:Failed times Assignment -


Mode Modify Measuremen
Attempts (MTC) t per Cell
(TCHH)

S422:Number of numb Interference -


Attemps in er Band
Interference Band Measuremen
t per TRX

R3134:Failed times Channel -


Queuing Attempts Assignment
due to Queue Queue
Overflow Measuremen
t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 181


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

CR313C:Failed times Channel -


Queuing Attempts Assignment
Queue
Measuremen
t per Cell

K3004:Traffic Erl KPI -


Volume on SDCCH Measuremen
t per Cell

K3014:Traffic Erl KPI -


Volume on TCH Measuremen
t per Cell

K3034:TCHH Erl KPI -


Traffic Volume Measuremen
t per Cell

R3550N:Traffic Erl Channel -


Volume of Signaling State
Channels (TCH) Measuremen
t per Cell

R3550M:Traffic Erl Channel -


Volume of Signaling State
Channels (SDCCH) Measuremen
t per Cell

R3550L:Traffic Erl Channel -


Volume of Unknown State
Service on SDCCH Measuremen
t per Cell

R3550J:Traffic Erl Channel -


Volume of USSD State
Service on SDCCH Measuremen
t per Cell

R3550I:Traffic Erl Channel -


Volume of Short State
Message Service on Measuremen
SDCCH t per Cell

R3550H:Traffic Erl Channel -


Volume of Speech State
Service on SDCCH Measuremen
t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 182


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Retainability Report
Null

NE Type
BSC6900GSM, BSC6000

Object Type
GCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Retainabi ZTR304A:Call Drop % Call Drop -


lity Rate on TCH per cell Measuremen
Report (Excluding t per Cell
Handover)

ZTR304:Call Drop % Call Drop -


Rate on TCH per cell Measuremen
(including t per Cell
Handover)

ZTR104C:Call Drop % Call Drop -


Rate on SDCCH Measuremen
t per Cell

RM317:Call Drop % Call Drop -


Rate on TCHF per Measuremen
cell t per Cell

RM327:Call Drop % Call Drop -


Rate on TCHH per Measuremen
cell t per Cell

RM330:Call Drop % Call Drop -


Rate on TCH on the Measuremen
TRX in the Underlaid t per Cell
Subcell

RM330a:Call Drop % Call Drop -


Rate on TCH on the Measuremen
TRX in the OverLaid t per Cell
Subcell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 183


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

ZTR308:Traffic Call none Channel -


Drop Ratio per cell State
Measuremen
t per Cell

ZTR104B:Call Drop % SDCCH Call -


Rate on SDCCH Drop
(Call Type) Measuremen
t per Cell

Worst Cell Report


Null

NE Type
BSC6900GSM, BSC6000

Object Type
GCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Worst R3550N:Traffic Erl Channel -


Cell Volume of Signaling State
Report Channels (TCH) Measuremen
t per Cell

ZTR304:Call Drop % Call Drop -


Rate on TCH per cell Measuremen
(including t per Cell
Handover)

ZTR304A:Call Drop % Call Drop -


Rate on TCH per cell Measuremen
(Excluding t per Cell
Handover)

K3041:TCH % KPI -
Congestion Rate Measuremen
(Overflow) t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 184


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

BSC KPI Overview Report


Null

NE Type
BSC6900GSM, BSC6000

Object Type
GBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

CS RA303G:Success % Immediate -
Accessab Rate of Immediate Assignment
lity KPI Assignments Measuremen
t per Cell

RR370:Congestion % Channel -
Rate on SDCCH per Assignment
CELL (due to Busy) Failure
Measuremen
t per Cell

ZTR104C:Call Drop % Call Drop -


Rate on SDCCH Measuremen
t per Cell

Assignment Success none Assignment [CA313:Successful


Rate Measuremen Assignments]/
t per Cell [CA310:Assignment Requests]
*{100}

K3041:TCH % KPI -
Congestion Rate Measuremen
(Overflow) t per Cell

K3043:TCH Seizure % KPI -


Success Rate Measuremen
t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 185


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Success Rate of Call none Assignment ([CA313:Successful


Establishment(V2) Measuremen Assignments]-
t per Cell ([A3100K:Assignment
Requests (Signaling Channel)
(SDCCH)]+[A3100A:Assign-
ment Requests (Signaling
Channel) (TCH)]-
[A312S:Failed Assignments
(Signaling Channel)]+
[CA310A:Assignment
Requests (TCH Assigned
Repeatedly over A Interface)]-
[CA312A:Failed Assignments
(TCH Assigned Repeatedly
over A Interface)]))/
([A3039J:SDCCH Seizures for
Speech Service]+
[A301F:TCHF Seizures for
Speech Service]+
[A301HH:TCHH Seizures for
Speech Service])*{100}

BSS Call none Immediate ((([CA303J:Call Setup


Establishment Assignment Indications (Circuit Service)])*
Success Rate Measuremen {100}/([CA300J:Channel
t per Cell Requests (Circuit Service)]))/
{100})*((([CA313:Successful
Assignments])*{100}/
([CA310:Assignment
Requests]))/{100})*({1}-
((([CM30:Call Drops on
SDCCH])*{100}/
([K3003:Successful SDCCH
Seizures]))/{100}))*{100}

OVERLOAD rate of none Flow Control ([L3188C:MSG CCCH LOAD


paging Measuremen IND (PCH) Messages Sent on
t per Cell Abis Interface (CS Service)]+
[L3188D:MSG CCCH LOAD
IND (PCH) Messages Sent on
Abis Interface (PS Service)])/
([A330:Delivered Paging
Messages for CS Service]+
[A331:Delivered Paging
Messages for PS Service])*
{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 186


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

CS ZTR304:Call Drop % Call Drop -


Retainabi Rate on TCH per cell Measuremen
lity KPI (including t per Cell
Handover)

ZTR304A:Call Drop % Call Drop -


Rate on TCH per cell Measuremen
(Excluding t per Cell
Handover)

Traffic Call Drop none KPI {60}*[K3014:Traffic Volume


Ratio per cell(V2) Measuremen on TCH]/[CM33:Call Drops on
t per Cell Traffic Channel]*{100}

RM333:Radio Drop % Call Drop -


Rate of TCH Measuremen
t per Cell

RH333:Handover % Intra-cell -
Drop Rate of TCH Handover
Measuremen
t per Cell

CS RH303:Handover % Incoming -
Mobility Success Rate Internal
KPI Inter-Cell
Handover
Measuremen
t per Cell

RH303A:Success % Incoming -
Rate of Radio Internal
Handover Inter-Cell
Handover
Measuremen
t per Cell

RH303B:Intra-BSC % Intra-cell -
Handover Success Handover
Rate Measuremen
t per Cell

RH303C:Intra-BSC % Intra-cell -
Radio Handover Handover
Success Rate Measuremen
t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 187


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

TH343:Success Rate % Incoming -


of Incoming External External
Inter-Cell Handovers Inter-Cell
Handover
Measuremen
t per Cell

RH303D:Success % Incoming -
Rate of Incoming External
External Inter-Cell Inter-Cell
Radio Handovers Handover
Measuremen
t per Cell

TH333:Success Rate % Outgoing -


of Outgoing External External
Inter-Cell Handovers Inter-Cell
Handover
Measuremen
t per Cell

RH303E:Success % Outgoing -
Rate of External External
Outgoing Cell Radio Inter-Cell
Handovers Handover
Measuremen
t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 188


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Success Rate of none Incoming (([RH3031G:Incoming


Dual-Band Internal Internal Inter-Cell Handover
Handovers (900M/ Inter-Cell Requests
850M-1800M/ Handover (900/850/810-1800/1900)]+
1900M)(V2) Measuremen [RH3033G:Incoming External
t per Cell Inter-Cell Handover Requests
(900/850/810-1800/1900)]+
[RH3035G:Outgoing External
Inter-Cell Handover Requests
(900/850/810-1800/1900)])-
([RH3031F:Failed Incoming
Internal Inter-Cell Handovers
(900/850/810-1800/1900)]+
[RH3033F:Failed Incoming
External Inter-Cell Handovers
(900/850/810-1800/1900)]+
[RH3035F:Failed Outgoing
External Inter-Cell Handovers
(900/850/810-1800/1900)]))/
([RH3031G:Incoming Internal
Inter-Cell Handover Requests
(900/850/810-1800/1900)]+
[RH3033G:Incoming External
Inter-Cell Handover Requests
(900/850/810-1800/1900)]+
[RH3035G:Outgoing External
Inter-Cell Handover Requests
(900/850/810-1800/1900)])*
{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 189


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Success Rate of none Incoming (([RH3032G:Incoming


Dual-Band Internal Internal Inter-Cell Handover
Handovers (1800M/ Inter-Cell Requests
1900M-900M/ Handover (1800/1900-900/850/810)]+
850M)(V2) Measuremen [RH3034G:Incoming External
t per Cell Inter-Cell Handover Requests
(1800/1900-900/850/810)]+
[RH3036G:Outgoing External
Inter-Cell Handover Requests
(1800/1900-900/850/810)])-
([RH3032F:Failed Incoming
Internal Inter-Cell Handovers
(1800/1900-900/850/810)]+
[RH3034F:Failed Incoming
External Inter-Cell Handovers
(1800/1900-900/850/810)]+
[RH3036F:Failed Outgoing
External Inter-Cell Handovers
(1800/1900-900/850/810)]))/
([RH3032G:Incoming Internal
Inter-Cell Handover Requests
(1800/1900-900/850/810)]+
[RH3034G:Incoming External
Inter-Cell Handover Requests
(1800/1900-900/850/810)]+
[RH3036G:Outgoing External
Inter-Cell Handover Requests
(1800/1900-900/850/810)])*
{100}

CS Traffic Volume on none KPI [K3014:Traffic Volume on


Resource TCH(V2) Measuremen TCH]
Usage t per Cell
Ratio
KPI TCHH Traffic none KPI [K3034:TCHH Traffic
Volume(V2) Measuremen Volume]
t per Cell

Traffic Volume on none KPI [K3004:Traffic Volume on


SDCCH(V2) Measuremen SDCCH]
t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 190


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

TCH Availability none Channel ([CR3027:Mean Number of


(V2) Configuratio Available Channels (TCHF)]+
n [CR3028:Mean Number of
Measuremen Available Channels (TCHH)])/
t per Cell ([CR3017:Mean Number of
Dynamically Configured
Channels (TCHF)]+
[CR3018:Mean Number of
Dynamically Configured
Channels (TCHH)])*{100}

SDCCH Availability none Channel [CR3020:Mean Number of


(V2) Configuratio Available Channels
n (SDCCH)]/[CR3010:Mean
Measuremen Number of Dynamically
t per Cell Configured Channels
(SDCCH)]*{100}

RK3255:TRX % KPI -
Usability Measuremen
t per Cell

PS Successful Uplink none Packet [A9502:Number of Successful


Accessab Assignment Rate Assignment Uplink Assignments]/
lity KPI Capability [A9501:Number of Uplink
Measuremen Assignments]*{100}
t

Successful Downlink none Packet [A9508:Number of Successful


Assignment Rate Assignment Downlink Assignments]/
Capability [A9507:Number of Downlink
Measuremen Assignments]*{100}
t

Uplink TBF none Uplink ([A9002:Number of Successful


Establishment GPRS TBF Uplink GPRS TBF
Success Rate Establish and Establishments]+
Release [A9202:Number of Successful
Capability Uplink EGPRS TBF
Measuremen Establishments])/
t ([A9001:Number of Uplink
GPRS TBF Establishment
Attempts]+[A9201:Number of
Uplink EGPRS TBF
Establishment Attempts])*
{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 191


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Downlink TBF none Downlink ([A9102:Number of Successful


Establishment GPRS TBF Downlink GPRS TBF
Success Rate Establish and Establishments]+
Release [A9302:Number of Successful
Capability Downlink EGPRS TBF
Measuremen Establishments])/
t ([A9101:Number of Downlink
GPRS TBF Establishment
Attempts]+[A9301:Number of
Downlink EGPRS TBF
Establishment Attempts])*
{100}

Uplink EGPRS none Uplink [A9202:Number of Successful


Establishment EGPRS TBF Uplink EGPRS TBF
Success Rate Establish and Establishments]/
Release [A9201:Number of Uplink
Capability EGPRS TBF Establishment
Measuremen Attempts]*{100}
t

Downlink EGPRS none Downlink [A9302:Number of Successful


Establishment EGPRS TBF Downlink EGPRS TBF
Success Rate Establish and Establishments]/
Release [A9301:Number of Downlink
Capability EGPRS TBF Establishment
Measuremen Attempts]*{100}
t

Uplink TBF none Uplink ([A9003:Number of Failed


Congestion Rate GPRS TBF Uplink GPRS TBF
Establish and Establishments due to No
Release Channel]+[A9203:Number of
Capability Failed Uplink EGPRS TBF
Measuremen Establishments due to No
t Channel])/([A9001:Number of
Uplink GPRS TBF
Establishment Attempts]+
[A9201:Number of Uplink
EGPRS TBF Establishment
Attempts])*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 192


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Downlink TBF none Downlink ([A9103:Number of Failed


Congestion Rate GPRS TBF Downlink GPRS TBF
Establish and Establishments due to No
Release Channel]+[A9303:Number of
Capability Failed Downlink EGPRS TBF
Measuremen Establishments due to No
t Channel])/([A9101:Number of
Downlink GPRS TBF
Establishment Attempts]+
[A9301:Number of Downlink
EGPRS TBF Establishment
Attempts])*{100}

Uplink EGPRS TBF none Uplink [A9203:Number of Failed


Congestion Rate EGPRS TBF Uplink EGPRS TBF
Establish and Establishments due to No
Release Channel]/[A9201:Number of
Capability Uplink EGPRS TBF
Measuremen Establishment Attempts]*
t {100}

Downlink EGPRS none Downlink [A9303:Number of Failed


TBF Congestion EGPRS TBF Downlink EGPRS TBF
Rate Establish and Establishments due to No
Release Channel]/[A9301:Number of
Capability Downlink EGPRS TBF
Measuremen Establishment Attempts]*
t {100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 193


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

PS Uplink TBF Drop none Uplink ([A9006:Number of Uplink


Retainabi Rate(%) GPRS TBF GPRS TBF Abnormal Releases
lity KPI Establish and due to N3101 Overflow (MS
Release No Response)]+
Capability [A9007:Number of Uplink
Measuremen GPRS TBF Abnormal Releases
t due to N3103 Overflow (MS
No Response)]+
[A9206:Number of Uplink
EGPRS TBF Abnormal
Releases due to N3101
Overflow (MS No Response)]+
[A9207:Number of Uplink
EGPRS TBF Abnormal
Releases due to N3103
Overflow (MS No
Response)])/([A9002:Number
of Successful Uplink GPRS
TBF Establishments]+
[A9202:Number of Successful
Uplink EGPRS TBF
Establishments])*{100}

Downlink TBF Drop none Downlink ([A9118:Number of Downlink


Rate(%) GPRS TBF GPRS Intermit Transfers]+
Establish and [A9318:Number of Downlink
Release EGPRS Intermit Transfers])/
Capability ([A9102:Number of Successful
Measuremen Downlink GPRS TBF
t Establishments]+
[A9302:Number of Successful
Downlink EGPRS TBF
Establishments])*{100}

Uplink EGPRS TBF none Uplink ([A9206:Number of Uplink


Drop Rate EGPRS TBF EGPRS TBF Abnormal
Establish and Releases due to N3101
Release Overflow (MS No Response)]+
Capability [A9207:Number of Uplink
Measuremen EGPRS TBF Abnormal
t Releases due to N3103
Overflow (MS No
Response)])/[A9202:Number
of Successful Uplink EGPRS
TBF Establishments]*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 194


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Downlink EGPRS none Downlink [A9318:Number of Downlink


TBF Drop Rate EGPRS TBF EGPRS Intermit Transfers]/
Establish and [A9302:Number of Successful
Release Downlink EGPRS TBF
Capability Establishments]*{100}
Measuremen
t

PS Retransmission Rate none Uplink ({1}-(([L9006:Number of


Transmis of Uplink GPRS GPRS RLC Valid Uplink RLC Data Blocks
sion RLC Data Blocks(%) Data Using CS1]+[L9007:Number
Performa Transfer of Valid Uplink RLC Data
nce KPI Capability Blocks Using CS2]+
Measuremen [L9008:Number of Valid
t Uplink RLC Data Blocks
Using CS3]+[L9009:Number
of Valid Uplink RLC Data
Blocks Using CS4])/
[L9001:Total Number of
Uplink GPRS RLC Data
Blocks]))*{100}

Retransmission Rate none Downlink ({1}-(([L9106:Total Number


of Downlink GPRS GPRS RLC of Valid RLC Downlink Data
RLC Data Blocks(%) Data Blocks Using CS1]+
Transfer [L9107:Total Number of Valid
Capability RLC Downlink Data Blocks
Measuremen Using CS2]+[L9108:Total
t Number of Valid RLC
Downlink Data Blocks Using
CS3]+[L9109:Total Number of
Valid RLC Downlink Data
Block Using CS4])/
[L9101:Total Number of
Downlink GPRS RLC Data
Blocks]))*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 195


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Retransmission Rate none Uplink ({1}-(([L9211:Total Number


of Uplink EGPRS EGPRS RLC of Valid Uplink EGPRS MCS1
RLC Data Blocks(%) Data RLC Data Blocks]+
Transfer [L9212:Total Number of Valid
Capability Uplink EGPRS MCS2 RLC
Measuremen Data Blocks]+[L9213:Total
t Number of Valid Uplink
EGPRS MCS3 RLC Data
Blocks]+[L9214:Total
Number of Valid Uplink
EGPRS MCS4 RLC Data
Blocks]+[L9215:Total
Number of Valid Uplink
EGPRS MCS5 RLC Data
Blocks]+[L9216:Total
Number of Valid Uplink
EGPRS MCS6 RLC Data
Blocks]+[L9217:Total
Number of Valid Uplink
EGPRS MCS7 RLC Data
Blocks]+[L9218:Total
Number of Valid Uplink
EGPRS MCS8 RLC Data
Blocks]+[L9219:Total
Number of Valid Uplink
EGPRS MCS9 RLC Data
Blocks])/[L9201:Total
Number of Uplink EGPRS
RLC Data Blocks]))*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 196


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Retransmission Rate none Downlink ({1}-(([L9311:Total Number


of Downlink EGPRS EGPRS RLC of Valid Downlink EGPRS
RLC Data Blocks(%) Data MCS1 RLC Data Blocks]+
Transfer [L9312:Total Number of Valid
Capability Downlink EGPRS MCS2 RLC
Measuremen Data Blocks]+[L9313:Total
t Number of Valid Downlink
EGPRS MCS3 RLC Data
Blocks]+[L9314:Total
Number of Valid Downlink
EGPRS MCS4 RLC Data
Blocks]+[L9315:Total
Number of Valid Downlink
EGPRS MCS5 RLC Data
Blocks]+[L9316:Total
Number of Valid Downlink
EGPRS MCS6 RLC Data
Blocks]+[L9317:Total
Number of Valid Downlink
EGPRS MCS7 RLC Data
Blocks]+[L9318:Total
Number of Valid Downlink
EGPRS MCS8 RLC Data
Blocks]+[L9319:Total
Number of Valid Downlink
EGPRS MCS9 RLC Data
Blocks])/[L9301:Total
Number of Downlink EGPRS
RLC Data Blocks]))*{100}

Rate of Uplink GPRS none Uplink ([L9008:Number of Valid


RLC Coding Scheme GPRS RLC Uplink RLC Data Blocks
with CS3&CS4(%) Data Using CS3]+[L9009:Number
Transfer of Valid Uplink RLC Data
Capability Blocks Using CS4])/
Measuremen ([L9006:Number of Valid
t Uplink RLC Data Blocks
Using CS1]+[L9007:Number
of Valid Uplink RLC Data
Blocks Using CS2]+
[L9008:Number of Valid
Uplink RLC Data Blocks
Using CS3]+[L9009:Number
of Valid Uplink RLC Data
Blocks Using CS4])*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 197


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Rate of Downlink none Downlink ([L9108:Total Number of


GPRS RLC Coding GPRS RLC Valid RLC Downlink Data
Scheme with Data Blocks Using CS3]+
CS3&CS4(%) Transfer [L9109:Total Number of Valid
Capability RLC Downlink Data Block
Measuremen Using CS4])/([L9106:Total
t Number of Valid RLC
Downlink Data Blocks Using
CS1]+[L9107:Total Number of
Valid RLC Downlink Data
Blocks Using CS2]+
[L9108:Total Number of Valid
RLC Downlink Data Blocks
Using CS3]+[L9109:Total
Number of Valid RLC
Downlink Data Block Using
CS4])*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 198


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Rate of Uplink none Uplink ([L9217:Total Number of


EGPRS RLC Coding EGPRS RLC Valid Uplink EGPRS MCS7
Scheme with Data RLC Data Blocks]+
MCS7&MCS8&MC Transfer [L9218:Total Number of Valid
S9(%) Capability Uplink EGPRS MCS8 RLC
Measuremen Data Blocks]+[L9219:Total
t Number of Valid Uplink
EGPRS MCS9 RLC Data
Blocks])/([L9211:Total
Number of Valid Uplink
EGPRS MCS1 RLC Data
Blocks]+[L9212:Total
Number of Valid Uplink
EGPRS MCS2 RLC Data
Blocks]+[L9213:Total
Number of Valid Uplink
EGPRS MCS3 RLC Data
Blocks]+[L9214:Total
Number of Valid Uplink
EGPRS MCS4 RLC Data
Blocks]+[L9215:Total
Number of Valid Uplink
EGPRS MCS5 RLC Data
Blocks]+[L9216:Total
Number of Valid Uplink
EGPRS MCS6 RLC Data
Blocks]+[L9217:Total
Number of Valid Uplink
EGPRS MCS7 RLC Data
Blocks]+[L9218:Total
Number of Valid Uplink
EGPRS MCS8 RLC Data
Blocks]+[L9219:Total
Number of Valid Uplink
EGPRS MCS9 RLC Data
Blocks])*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 199


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Rate of Downlink none Downlink ([L9317:Total Number of


EGPRS RLC Coding EGPRS RLC Valid Downlink EGPRS
Scheme with Data MCS7 RLC Data Blocks]+
MCS7&MCS8&MC Transfer [L9318:Total Number of Valid
S9(%) Capability Downlink EGPRS MCS8 RLC
Measuremen Data Blocks]+[L9319:Total
t Number of Valid Downlink
EGPRS MCS9 RLC Data
Blocks])/([L9311:Total
Number of Valid Downlink
EGPRS MCS1 RLC Data
Blocks]+[L9312:Total
Number of Valid Downlink
EGPRS MCS2 RLC Data
Blocks]+[L9313:Total
Number of Valid Downlink
EGPRS MCS3 RLC Data
Blocks]+[L9314:Total
Number of Valid Downlink
EGPRS MCS4 RLC Data
Blocks]+[L9315:Total
Number of Valid Downlink
EGPRS MCS5 RLC Data
Blocks]+[L9316:Total
Number of Valid Downlink
EGPRS MCS6 RLC Data
Blocks]+[L9317:Total
Number of Valid Downlink
EGPRS MCS7 RLC Data
Blocks]+[L9318:Total
Number of Valid Downlink
EGPRS MCS8 RLC Data
Blocks]+[L9319:Total
Number of Valid Downlink
EGPRS MCS9 RLC Data
Blocks])*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 200


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Average Throughput none Uplink ([L9006:Number of Valid


of Uplink GPRS GPRS RLC Uplink RLC Data Blocks
RLC per PDCH Data Using CS1]*{23}+
(kbps) Transfer [L9007:Number of Valid
Capability Uplink RLC Data Blocks
Measuremen Using CS2]*{34}+
t [L9008:Number of Valid
Uplink RLC Data Blocks
Using CS3]*{40}+
[L9009:Number of Valid
Uplink RLC Data Blocks
Using CS4]*{54})*{8}/
({1024}*[L9001:Total
Number of Uplink GPRS RLC
Data Blocks]*{20}/{1000})

Average Throughput none Downlink ([L9106:Total Number of


of Downlink GPRS GPRS RLC Valid RLC Downlink Data
RLC per PDCH Data Blocks Using CS1]*{23}+
(kbps) Transfer [L9107:Total Number of Valid
Capability RLC Downlink Data Blocks
Measuremen Using CS2]*{34}+
t [L9108:Total Number of Valid
RLC Downlink Data Blocks
Using CS3]*{40}+
[L9109:Total Number of Valid
RLC Downlink Data Block
Using CS4]*{54})*{8}/
({1024}*[L9101:Total
Number of Downlink GPRS
RLC Data Blocks]*{20}/
{1000})

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 201


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Average Throughput none Uplink (([L9211:Total Number of


of Uplink EGPRS EGPRS RLC Valid Uplink EGPRS MCS1
RLC per PDCH Data RLC Data Blocks]*{22}+
(kbps) Transfer [L9212:Total Number of Valid
Capability Uplink EGPRS MCS2 RLC
Measuremen Data Blocks]*{28}+
t [L9213:Total Number of Valid
Uplink EGPRS MCS3 RLC
Data Blocks]*{37}+
[L9214:Total Number of Valid
Uplink EGPRS MCS4 RLC
Data Blocks]*{44}+
[L9215:Total Number of Valid
Uplink EGPRS MCS5 RLC
Data Blocks]*{56}+
[L9216:Total Number of Valid
Uplink EGPRS MCS6 RLC
Data Blocks]*{74}+
[L9217:Total Number of Valid
Uplink EGPRS MCS7 RLC
Data Blocks]*{56}+
[L9218:Total Number of Valid
Uplink EGPRS MCS8 RLC
Data Blocks]*{68}+
[L9219:Total Number of Valid
Uplink EGPRS MCS9 RLC
Data Blocks]*{74})*{8})/
(({1024}*([L9202:Total
Number of Uplink EGPRS
MCS1 RLC Data Blocks]+
[L9203:Total Number of
Uplink EGPRS MCS2 RLC
Data Blocks]+[L9204:Total
Number of Uplink EGPRS
MCS3 RLC Data Blocks]+
[L9205:Total Number of
Uplink EGPRS MCS4 RLC
Data Blocks]+[L9206:Total
Number of Uplink EGPRS
MCS5 RLC Data Blocks]+
[L9207:Total Number of
Uplink EGPRS MCS6 RLC
Data Blocks]+[L9208:Total
Number of Uplink EGPRS
MCS7 RLC Data Blocks]/{2}+
[L9209:Total Number of
Uplink EGPRS MCS8 RLC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 202


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Data Blocks]/{2}+
[L9210:Total Number of
Uplink EGPRS MCS9 RLC
Data Blocks]/{2})*{20}/
{1000}))

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 203


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Average Throughput none Uplink (([L9311:Total Number of


of Downlink EGPRS EGPRS RLC Valid Downlink EGPRS
RLC per PDCH Data MCS1 RLC Data Blocks]*
(kbps) Transfer {22}+[L9312:Total Number of
Capability Valid Downlink EGPRS
Measuremen MCS2 RLC Data Blocks]*
t {28}+[L9313:Total Number of
Valid Downlink EGPRS
MCS3 RLC Data Blocks]*
{37}+[L9314:Total Number of
Valid Downlink EGPRS
MCS4 RLC Data Blocks]*
{44}+[L9315:Total Number of
Valid Downlink EGPRS
MCS5 RLC Data Blocks]*
{56}+[L9316:Total Number of
Valid Downlink EGPRS
MCS6 RLC Data Blocks]*
{74}+[L9317:Total Number of
Valid Downlink EGPRS
MCS7 RLC Data Blocks]*
{56}+[L9318:Total Number of
Valid Downlink EGPRS
MCS8 RLC Data Blocks]*
{68}+[L9319:Total Number of
Valid Downlink EGPRS
MCS9 RLC Data Blocks]*
{74})*{8})/(({1024}*
([L9302:Total Number of
Downlink EGPRS MCS1 RLC
Data Blocks]+[L9303:Total
Number of Downlink EGPRS
MCS2 RLC Data Blocks]+
[L9304:Total Number of
Downlink EGPRS MCS3 RLC
Data Blocks]+[L9305:Total
Number of Downlink EGPRS
MCS4 RLC Data Blocks]+
[L9306:Total Number of
Downlink EGPRS MCS5 RLC
Data Blocks]+[L9307:Total
Number of Downlink EGPRS
MCS6 RLC data blocks]+
[L9308:Total Number of
Downlink EGPRS MCS7 RLC
Data Blocks]/{2}+
[L9309:Total Number of

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 204


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Downlink EGPRS MCS8 RLC


Data Blocks]/{2}+
[L9310:Total Number of
Downlink EGPRS MCS9 RLC
Data Blocks]/{2})*{20}/
{1000}))

Average Throughput none Uplink ([L9006:Number of Valid


of Uplink GPRS GPRS RLC Uplink RLC Data Blocks
RLC per Cell(kbps) Data Using CS1]*{23}+
Transfer [L9007:Number of Valid
Capability Uplink RLC Data Blocks
Measuremen Using CS2]*{34}+
t [L9008:Number of Valid
Uplink RLC Data Blocks
Using CS3]*{40}+
[L9009:Number of Valid
Uplink RLC Data Blocks
Using CS4]*{54})*{8}/
({1024}*[L9020:Total
Duration of Uplink GPRS
TBFs])

Average Throughput none Downlink ([L9106:Total Number of


of Downlink GPRS GPRS RLC Valid RLC Downlink Data
RLC per Cell(kbps) Data Blocks Using CS1]*{23}+
Transfer [L9107:Total Number of Valid
Capability RLC Downlink Data Blocks
Measuremen Using CS2]*{34}+
t [L9108:Total Number of Valid
RLC Downlink Data Blocks
Using CS3]*{40}+
[L9109:Total Number of Valid
RLC Downlink Data Block
Using CS4]*{54})*{8}/
({1024}*[L9121:Total
Duration of Downlink GPRS
TBFs])

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 205


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Average Throughput none Uplink ([L9211:Total Number of


of Uplink EGPRS EGPRS RLC Valid Uplink EGPRS MCS1
RLC per Cell(kbps) Data RLC Data Blocks]*{22}+
Transfer [L9212:Total Number of Valid
Capability Uplink EGPRS MCS2 RLC
Measuremen Data Blocks]*{28}+
t [L9213:Total Number of Valid
Uplink EGPRS MCS3 RLC
Data Blocks]*{37}+
[L9214:Total Number of Valid
Uplink EGPRS MCS4 RLC
Data Blocks]*{44}+
[L9215:Total Number of Valid
Uplink EGPRS MCS5 RLC
Data Blocks]*{56}+
[L9216:Total Number of Valid
Uplink EGPRS MCS6 RLC
Data Blocks]*{74}+
[L9217:Total Number of Valid
Uplink EGPRS MCS7 RLC
Data Blocks]*{56}+
[L9218:Total Number of Valid
Uplink EGPRS MCS8 RLC
Data Blocks]*{68}+
[L9219:Total Number of Valid
Uplink EGPRS MCS9 RLC
Data Blocks]*{74})*{8}/
({1024}*[L9235:Total
Duration of Uplink EGPRS
TBFs])

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 206


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Average Throughput none Downlink ([L9311:Total Number of


of Downlink EGPRS EGPRS RLC Valid Downlink EGPRS
RLC per Cell(kbps) Data MCS1 RLC Data Blocks]*
Transfer {22}+[L9312:Total Number of
Capability Valid Downlink EGPRS
Measuremen MCS2 RLC Data Blocks]*
t {28}+[L9313:Total Number of
Valid Downlink EGPRS
MCS3 RLC Data Blocks]*
{37}+[L9314:Total Number of
Valid Downlink EGPRS
MCS4 RLC Data Blocks]*
{44}+[L9315:Total Number of
Valid Downlink EGPRS
MCS5 RLC Data Blocks]*
{56}+[L9316:Total Number of
Valid Downlink EGPRS
MCS6 RLC Data Blocks]*
{74}+[L9317:Total Number of
Valid Downlink EGPRS
MCS7 RLC Data Blocks]*
{56}+[L9318:Total Number of
Valid Downlink EGPRS
MCS8 RLC Data Blocks]*
{68}+[L9319:Total Number of
Valid Downlink EGPRS
MCS9 RLC Data Blocks]*
{74})*{8}/({1024}*
[L9336:Total Duration of
Downlink EGPRS TBFs])

Average Throughput none Uplink LLC [L9422:Throughput of Uplink


of Uplink GPRS LLC Data GPRS Users LLC PDU]/
per User(kbps) Transfer ([L9421:Total Bytes of Uplink
Capability GPRS Users LLC PDUs]*{8}/
Measuremen {1024})
t

Average Throughput none Downlink [L9526:Throughput of


of Downlink GPRS LLC Data Downlink GPRS Users LLC
LLC per User(kbps) Transfer PDU]/([L9525:Total Bytes of
Capability Downlink GPRS Users LLC
Measuremen PDU]*{8}/{1024})
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 207


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Average Throughput none Uplink LLC [L9424:Throughput of Uplink


of Uplink EGPRS Data EGPRS Users LLC PDU]/
LLC per User(kbps) Transfer ([L9423:Total Bytes of Uplink
Capability EGPRS Users LLC PDUs]*
Measuremen {8}/{1024})
t

Average Throughput none Downlink [L9528:Throughput of


of Downlink EGPRS LLC Data Downlink EGPRS Users LLC
LLC per User(kbps) Transfer PDU]/([L9527:Total Bytes of
Capability Downlink EGPRS Users LLC
Measuremen PDU]*{8}/{1024})
t

PS Uplink PDTCH/ none Cell Radio [R9204:Number of RLC Data


Resource PACCH Utilization Channel Blocks Received on Uplink
Usage Rate Capability PDTCH/PACCH]/
Ratio Measuremen [R9206:Total Number of
KPI t Uplink PDTCH/PACCH
Blocks]*{100}

Downlink PDTCH/ none Cell Radio [R9205:Number of RLC Data


PACCH Utilization Channel Blocks Sent on Downlink
Rate Capability PDTCH/PACCH]/
Measuremen [R9207:Total Number of
t Downlink PDTCH/PACCH
Blocks]*{100}

PDCH Occupation none PDCH [AR9311:Average Number of


Rate Resource Occupied PDCHs]/
Capability [AR9303:Average Number of
Measuremen Available PDCHs]*{100}
t

BSC Reclaimed none PDCH [R9344:Number of Reclaimed


Dynamic PDCH Rate Resource Busy Dynamic PDCHs]/
Capability [R9343:Number of Reclaimed
Measuremen Dynamic PDCHs]*{100}
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 208


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

5.8 GSM Network Performance Monitoring Report (Team


Leader)
Report Type
Combined Report

Simple Report(s) List


l Whole Network KPI Report
l GSM BSC KPI Report

Whole Network KPI Report


Null

NE Type
BSC6900GSM, BSC6000

Object Type
GCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Whole RCA313:Assign- % Assignment -


Network ment Success Rate Measuremen
KPI t per Cell
Report
K3043:TCH Seizure % KPI -
Success Rate Measuremen
t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 209


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

RA303G:Success % Immediate -
Rate of Immediate Assignment
Assignments Measuremen
t per Cell

RA301G:Success % Immediate -
Rate of Random Assignment
Access Measuremen
t per Cell

TH323:Success Rate % Incoming -


of Incoming Internal Internal
Inter-Cell Handovers Inter-Cell
Handover
Measuremen
t per Cell

RH303:Handover % Incoming -
Success Rate Internal
Inter-Cell
Handover
Measuremen
t per Cell

RH303A:Success % Incoming -
Rate of Radio Internal
Handover Inter-Cell
Handover
Measuremen
t per Cell

TH303:Success Rate % Intra-cell -


of Internal Intra-Cell Handover
Handover Measuremen
t per Cell

ZTR104C:Call Drop % Call Drop -


Rate on SDCCH Measuremen
t per Cell

ZTR304:Call Drop % Call Drop -


Rate on TCH per cell Measuremen
(including t per Cell
Handover)

ZTR304A:Call Drop % Call Drop -


Rate on TCH per cell Measuremen
(Excluding t per Cell
Handover)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 210


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

RR370:Congestion % Channel -
Rate on SDCCH per Assignment
CELL (due to Busy) Failure
Measuremen
t per Cell

K3041:TCH % KPI -
Congestion Rate Measuremen
(Overflow) t per Cell

K3045:Congestion % KPI -
Rate on TCH (All Measuremen
Channels Busy) t per Cell

K3014:Traffic Erl KPI -


Volume on TCH Measuremen
t per Cell

K3004:Traffic Erl KPI -


Volume on SDCCH Measuremen
t per Cell

RR307:TCH % Channel -
Availability Configuratio
n
Measuremen
t per Cell

RR300:SDCCH % Channel -
Availability Configuratio
n
Measuremen
t per Cell

ZTR308:Traffic Call none Channel -


Drop Ratio per cell State
Measuremen
t per Cell

GSM BSC KPI Report


Null

NE Type
BSC6900GSM, BSC6000

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 211


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Object Type
GCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

GSM RCA313:Assign- % Assignment -


BSC KPI ment Success Rate Measuremen
Report t per Cell

K3043:TCH Seizure % KPI -


Success Rate Measuremen
t per Cell

RA303G:Success % Immediate -
Rate of Immediate Assignment
Assignments Measuremen
t per Cell

RA301G:Success % Immediate -
Rate of Random Assignment
Access Measuremen
t per Cell

TH323:Success Rate % Incoming -


of Incoming Internal Internal
Inter-Cell Handovers Inter-Cell
Handover
Measuremen
t per Cell

RH303:Handover % Incoming -
Success Rate Internal
Inter-Cell
Handover
Measuremen
t per Cell

RH303A:Success % Incoming -
Rate of Radio Internal
Handover Inter-Cell
Handover
Measuremen
t per Cell

TH303:Success Rate % Intra-cell -


of Internal Intra-Cell Handover
Handover Measuremen
t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 212


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

ZTR104C:Call Drop % Call Drop -


Rate on SDCCH Measuremen
t per Cell

ZTR304A:Call Drop % Call Drop -


Rate on TCH per cell Measuremen
(Excluding t per Cell
Handover)

ZTR304:Call Drop % Call Drop -


Rate on TCH per cell Measuremen
(including t per Cell
Handover)

RR370:Congestion % Channel -
Rate on SDCCH per Assignment
CELL (due to Busy) Failure
Measuremen
t per Cell

K3041:TCH % KPI -
Congestion Rate Measuremen
(Overflow) t per Cell

K3045:Congestion % KPI -
Rate on TCH (All Measuremen
Channels Busy) t per Cell

K3014:Traffic Erl KPI -


Volume on TCH Measuremen
t per Cell

K3004:Traffic Erl KPI -


Volume on SDCCH Measuremen
t per Cell

RR307:TCH % Channel -
Availability Configuratio
n
Measuremen
t per Cell

RR300:SDCCH % Channel -
Availability Configuratio
n
Measuremen
t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 213


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

ZTR308:Traffic Call none Channel -


Drop Ratio per cell State
Measuremen
t per Cell

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

5.9 Retainability Report


Report Type
Simple Report

NE Type
BSC6900GSM, BSC6000

Object Type
GCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Retainabi ZTR304A:Call Drop % Call Drop -


lity Rate on TCH per cell Measuremen
Report (Excluding t per Cell
Handover)

ZTR304:Call Drop % Call Drop -


Rate on TCH per cell Measuremen
(including t per Cell
Handover)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 214


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

ZTR104C:Call Drop % Call Drop -


Rate on SDCCH Measuremen
t per Cell

RM317:Call Drop % Call Drop -


Rate on TCHF per Measuremen
cell t per Cell

RM327:Call Drop % Call Drop -


Rate on TCHH per Measuremen
cell t per Cell

RM330:Call Drop % Call Drop -


Rate on TCH on the Measuremen
TRX in the Underlaid t per Cell
Subcell

RM330a:Call Drop % Call Drop -


Rate on TCH on the Measuremen
TRX in the OverLaid t per Cell
Subcell

ZTR308:Traffic Call none Channel -


Drop Ratio per cell State
Measuremen
t per Cell

ZTR104B:Call Drop % SDCCH Call -


Rate on SDCCH Drop
(Call Type) Measuremen
t per Cell

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

5.10 Extra Busy Cell Report


Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 215


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

NE Type
BSC6900GSM, BSC6000

Object Type
GCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Extra R3550N:Traffic Erl Channel -


Busy Volume of Signaling State
Cell Channels (TCH) Measuremen
Report t per Cell

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

5.11 Extra Idle Cell Report


Report Type
Simple Report

NE Type
BSC6900GSM, BSC6000

Object Type
GCell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 216


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Extra R3550N:Traffic Erl Channel -


Idle Cell Volume of Signaling State
Report Channels (TCH) Measuremen
t per Cell

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

5.12 Call Drop Cell Report


Report Type
Simple Report

NE Type
BSC6900GSM, BSC6000

Object Type
GCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Call ZTR304A:Call Drop % Call Drop -


Drop Rate on TCH per cell Measuremen
Cell (Excluding t per Cell
Report Handover)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 217


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

ZTR304:Call Drop % Call Drop -


Rate on TCH per cell Measuremen
(including t per Cell
Handover)

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

5.13 Accessibility Report


Report Type
Simple Report

NE Type
BSC6900GSM, BSC6000

Object Type
GCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Accessib RA303G:Success % Immediate -


ility Rate of Immediate Assignment
Report Assignments Measuremen
t per Cell

K3100:Immediate times KPI -


Assignment Measuremen
Requests t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 218


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

A9503:Number of times Packet -


Uplink PS Immediate Assignment
Assignments Capability
Measuremen
t

A9504:Number of times Packet -


Successful Uplink PS Assignment
Immediate Capability
Assignments Measuremen
t

A9509:Number of times Packet -


Downlink PS Assignment
Immediate Capability
Assignments Measuremen
t

A9510:Number of times Packet -


Successful Downlink Assignment
PS Immediate Capability
Assignments Measuremen
t

R3100A:Channel times Channel -


Assignment Assignment
Requests in Request
Immediate Measuremen
Assignment t per Cell
Procedure (SDCCH)

R3109A:Channel times Channel -


Assignment Assignment
Requests in Request
Immediate Measuremen
Assignment t per Cell
Procedure (TCH)

K3010A:TCH times KPI -


Seizure Requests Measuremen
(Traffic Channel) t per Cell

K3043:TCH Seizure % KPI -


Success Rate Measuremen
t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 219


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

K3021:Failed TCH times KPI -


Seizures due to Busy Measuremen
TCH (Signaling t per Cell
Channel)

K3023:Successful times KPI -


TCH Seizures Measuremen
(Signaling Channel) t per Cell

ZTR104C:Call Drop % Call Drop -


Rate on SDCCH Measuremen
t per Cell

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

5.14 Whole Network KPI Report


Report Type
Simple Report

NE Type
BSC6900GSM, BSC6000

Object Type
GCell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 220


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Whole RCA313:Assign- % Assignment -


Network ment Success Rate Measuremen
KPI t per Cell
Report
K3043:TCH Seizure % KPI -
Success Rate Measuremen
t per Cell

RA303G:Success % Immediate -
Rate of Immediate Assignment
Assignments Measuremen
t per Cell

RA301G:Success % Immediate -
Rate of Random Assignment
Access Measuremen
t per Cell

TH323:Success Rate % Incoming -


of Incoming Internal Internal
Inter-Cell Handovers Inter-Cell
Handover
Measuremen
t per Cell

RH303:Handover % Incoming -
Success Rate Internal
Inter-Cell
Handover
Measuremen
t per Cell

RH303A:Success % Incoming -
Rate of Radio Internal
Handover Inter-Cell
Handover
Measuremen
t per Cell

TH303:Success Rate % Intra-cell -


of Internal Intra-Cell Handover
Handover Measuremen
t per Cell

ZTR104C:Call Drop % Call Drop -


Rate on SDCCH Measuremen
t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 221


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

ZTR304:Call Drop % Call Drop -


Rate on TCH per cell Measuremen
(including t per Cell
Handover)

ZTR304A:Call Drop % Call Drop -


Rate on TCH per cell Measuremen
(Excluding t per Cell
Handover)

RR370:Congestion % Channel -
Rate on SDCCH per Assignment
CELL (due to Busy) Failure
Measuremen
t per Cell

K3041:TCH % KPI -
Congestion Rate Measuremen
(Overflow) t per Cell

K3045:Congestion % KPI -
Rate on TCH (All Measuremen
Channels Busy) t per Cell

K3014:Traffic Erl KPI -


Volume on TCH Measuremen
t per Cell

K3004:Traffic Erl KPI -


Volume on SDCCH Measuremen
t per Cell

RR307:TCH % Channel -
Availability Configuratio
n
Measuremen
t per Cell

RR300:SDCCH % Channel -
Availability Configuratio
n
Measuremen
t per Cell

ZTR308:Traffic Call none Channel -


Drop Ratio per cell State
Measuremen
t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 222


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

5.15 Mobility Report


Report Type
Simple Report

NE Type
BSC6900GSM, BSC6000

Object Type
GCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Mobility RH303:Handover % Incoming -


Report Success Rate Internal
Inter-Cell
Handover
Measuremen
t per Cell

H3122C:Number of times Outgoing -


Unsuccessful Internal
Outgoing Internal Inter-Cell
Inter-Cell Handovers Handover
(Uplink Strength) Measuremen
t per Cell

H3122B:Number of times Outgoing -


Unsuccessful Internal
Outgoing Internal Inter-Cell
Inter-Cell Handovers Handover
(Downlink Quality) Measuremen
t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 223


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

H3122A:Number of times Outgoing -


Unsuccessful Internal
Outgoing Internal Inter-Cell
Inter-Cell Handovers Handover
(Uplink Quality) Measuremen
t per Cell

H311B:Number of times Outgoing -


Outgoing Internal Internal
Inter-Cell Handover Inter-Cell
Commands Handover
(Downlink Quality) Measuremen
t per Cell

H310O:Number of times Outgoing -


Outgoing Internal Internal
Inter-Cell Handover Inter-Cell
Requests (MS Handover
Handover in the Measuremen
Overlaid Subcell t per Cell
Covered by the
Enhanced Dualband
Network)

H310N:Number of times Outgoing -


Outgoing Internal Internal
Inter-Cell Handover Inter-Cell
Requests (Overlaid Handover
to Underlaid Subcell Measuremen
in Enhanced t per Cell
Dualband Network)

H310M:Number of times Outgoing -


Outgoing Internal Internal
Inter-Cell Handover Inter-Cell
Requests (Underlaid Handover
to Overlaid Subcell Measuremen
in Enhanced t per Cell
Dualband Network)

H310F:Number of times Outgoing -


Outgoing Internal Internal
Inter-Cell Handover Inter-Cell
Requests (Better Handover
Cell) Measuremen
t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 224


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

H310G:Number of times Outgoing -


Outgoing Internal Internal
Inter-Cell Handover Inter-Cell
Requests (Load) Handover
Measuremen
t per Cell

H310H:Number of times Outgoing -


Outgoing Internal Internal
Inter-Cell Handover Inter-Cell
Requests (Rapid Handover
Level Drop) Measuremen
t per Cell

H3100Y:Number of times Outgoing -


Outgoing Internal Internal
Inter-Cell Handover Inter-Cell
Requests (SDCCH) Handover
(Excluding Directed Measuremen
Retry) t per Cell
(900/850/810-1800/
1900)

CH370a:Number of times Outgoing -


Successful Outgoing Internal
Internal Inter-Cell Inter-Cell
Handovers During Handover
BSC Local Switch Measuremen
t per Cell

CH370b:Number of times Outgoing -


Successful Outgoing Internal
Internal Inter-Cell Inter-Cell
Handovers During Handover
BTS Local Switch Measuremen
t per Cell

CH312C:Number of times Outgoing -


Unsuccessful Internal
Outgoing Internal Inter-Cell
Inter-Cell Handovers Handover
(Timer Expired) Measuremen
t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 225


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

5.16 Congestion Cell Report


Report Type
Simple Report

NE Type
BSC6900GSM, BSC6000

Object Type
GCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Congesti K3045:Congestion % KPI -


on Cell Rate on TCH (All Measuremen
Report Channels Busy) t per Cell

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

5.17 Resource Utilization Report


Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 226


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

NE Type
BSC6900GSM, BSC6000

Object Type
GCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Resource RR307:TCH % Channel -


Utilizatio Availability Configuratio
n Report n
Measuremen
t per Cell

K3015:Available numb KPI -


TCHs er Measuremen
t per Cell

K3005:Available numb KPI -


SDCCHs er Measuremen
t per Cell

K3006:Configured numb KPI -


SDCCHs er Measuremen
t per Cell

K3016:Configured numb KPI -


TCHs er Measuremen
t per Cell

RCA313:Assign- % Assignment -
ment Success Rate Measuremen
t per Cell

A3157A:Failed times Assignment -


Mode Modify Measuremen
Attempts (MOC) t per Cell
(TCHF)

A3157C:Failed times Assignment -


Mode Modify Measuremen
Attempts (MTC) t per Cell
(TCHF)

A3158A:Failed times Assignment -


Mode Modify Measuremen
Attempts (MOC) t per Cell
(TCHH)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 227


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

A3158C:Failed times Assignment -


Mode Modify Measuremen
Attempts (MTC) t per Cell
(TCHH)

S422:Number of numb Interference -


Attemps in er Band
Interference Band Measuremen
t per TRX

R3134:Failed times Channel -


Queuing Attempts Assignment
due to Queue Queue
Overflow Measuremen
t per Cell

CR313C:Failed times Channel -


Queuing Attempts Assignment
Queue
Measuremen
t per Cell

K3004:Traffic Erl KPI -


Volume on SDCCH Measuremen
t per Cell

K3014:Traffic Erl KPI -


Volume on TCH Measuremen
t per Cell

K3034:TCHH Erl KPI -


Traffic Volume Measuremen
t per Cell

R3550N:Traffic Erl Channel -


Volume of Signaling State
Channels (TCH) Measuremen
t per Cell

R3550M:Traffic Erl Channel -


Volume of Signaling State
Channels (SDCCH) Measuremen
t per Cell

R3550L:Traffic Erl Channel -


Volume of Unknown State
Service on SDCCH Measuremen
t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 228


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

R3550J:Traffic Erl Channel -


Volume of USSD State
Service on SDCCH Measuremen
t per Cell

R3550I:Traffic Erl Channel -


Volume of Short State
Message Service on Measuremen
SDCCH t per Cell

R3550H:Traffic Erl Channel -


Volume of Speech State
Service on SDCCH Measuremen
t per Cell

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

5.18 Worst Cell Report


Report Type
Simple Report

NE Type
BSC6900GSM, BSC6000

Object Type
GCell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 229


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Worst R3550N:Traffic Erl Channel -


Cell Volume of Signaling State
Report Channels (TCH) Measuremen
t per Cell

ZTR304:Call Drop % Call Drop -


Rate on TCH per cell Measuremen
(including t per Cell
Handover)

ZTR304A:Call Drop % Call Drop -


Rate on TCH per cell Measuremen
(Excluding t per Cell
Handover)

K3041:TCH % KPI -
Congestion Rate Measuremen
(Overflow) t per Cell

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

5.19 BTS Energy Consumption Report

5.19.1 BTS Traffic and Energy Consumption Report


Report Type
Simple Report

NE Type
BSC6000(GSMR)

Object Type
GBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 230


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

BTS Energy Consumption none Site Power [CR2791:BTS Power


Traffic (kwh) Consumption Consumption by Adding Static
and Measuremen Power Consumption]
Energy t (for Site)
Consump
tion CS Traffic(Erl) none KPI [K3014:Traffic Volume on
Report Measuremen TCH]+[K3004:Traffic
t per Cell Volume on SDCCH]

PS Traffic(kbit) none Downlink [L9503:Total Bytes of


LLC Data Downlink LLC PDUs
Transfer Received]*{8}/{1000}
Capabilty
Measuremen
t

Total Traffic(kbit) none KPI ([K3034:TCHH Traffic


Measuremen Volume]*{11.4}*{GP}*{60}
t per Cell +([K3014:Traffic Volume on
TCH]-[K3034:TCHH Traffic
Volume]-[AR3551C:Traffic
Volume on AMR TCHFs]-
[AR3552C:Traffic Volume on
AMR TCHHs])*{22.8}*{GP}
*{60}+[AR3551C:Traffic
Volume on AMR TCHFs]*
{22.8}*{GP}*{60}+
[AR3552C:Traffic Volume on
AMR TCHHs]*{22.8}*{GP}*
{60})*{0.7}+[K3004:Traffic
Volume on SDCCH]*{22.8}*
{GP}*{60}+[L9503:Total
Bytes of Downlink LLC PDUs
Received]*{8}/{1000}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 231


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

5.19.2 Network Energy Efficiency Indicator Report

Report Type
Simple Report

NE Type
BSC6000(GSMR)

Object Type
GBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Network EE(bit/joule) none KPI (([K3034:TCHH Traffic


Energy Measuremen Volume]*{11.4}*{GP}*{60}
Efficienc t per Cell +([K3014:Traffic Volume on
y TCH]-[K3034:TCHH Traffic
Indicator Volume]-[AR3551C:Traffic
Report Volume on AMR TCHFs]-
[AR3552C:Traffic Volume on
AMR TCHHs])*{22.8}*{GP}
*{60}+[AR3551C:Traffic
Volume on AMR TCHFs]*
{22.8}*{GP}*{60}+
[AR3552C:Traffic Volume on
AMR TCHHs]*{22.8}*{GP}*
{60})*{0.7}+[K3004:Traffic
Volume on SDCCH]*{22.8}*
{GP}*{60}+[L9503:Total
Bytes of Downlink LLC PDUs
Received]*{8}/{1000})/
[CR2791:BTS Power
Consumption by Adding Static
Power Consumption]/{3600}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 232


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 5 GSM BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 233


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

6 GU SingleRAN Performance Report

About This Chapter

6.1 Relate Report

6.2 GU Interoperations Report

6.3 GU CoRRM Report

6.4 GU Power Sharing Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 234


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

6.1 Relate Report

6.1.1 GSM Interoperations Report

Report Type
Simple Report

NE Type
2GBSC

Object Type
GCell Group

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

GSM CH350:Outgoing none Outgoing -


Interoper Inter-RAT Inter-Cell Inter-RAT
ations Handover Requests Inter-Cell
Report Handover
Measuremen
t per Cell

CH351:Outgoing none Outgoing -


Inter-RAT Inter-Cell Inter-RAT
Handover Inter-Cell
Commands Handover
Measuremen
t per Cell

CH353:Successful none Outgoing -


Outgoing Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
Handover
Measuremen
t per Cell

GSM Voice none Outgoing [CH351:Outgoing Inter-RAT


Outgoing Inter-RAT Inter-RAT Inter-Cell Handover
Inter-Cell Handover Inter-Cell Commands]/
Preparation Success Handover [CH350:Outgoing Inter-RAT
Rate Measuremen Inter-Cell Handover Requests]
t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 235


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

GSM Voice none Outgoing [CH353:Successful Outgoing


Outgoing Inter-RAT Inter-RAT Inter-RAT Inter-Cell
Inter-Cell Handover Inter-Cell Handovers]/[CH351:Outgoing
Success Rate Handover Inter-RAT Inter-Cell Handover
Measuremen Commands]
t per Cell

CH360:Incoming none Incoming -


Inter-RAT Inter-Cell Inter-RAT
Handover Requests Inter-Cell
Handover
Measuremen
t per Cell

CH361:Incoming none Incoming -


Inter-RAT Inter-Cell Inter-RAT
Handover Responses Inter-Cell
Handover
Measuremen
t per Cell

CH363:Successful none Incoming -


Incoming Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
Handover
Measuremen
t per Cell

Success Rate of % Incoming [CH361:Incoming Inter-RAT


Preparation for Inter-RAT Inter-Cell Handover
Incoming Inter-RAT Inter-Cell Responses]/[CH360:Incoming
Inter-Cell Handover Handover Inter-RAT Inter-Cell Handover
Measuremen Requests]
t per Cell

Success Rate of % Incoming [CH363:Successful Incoming


Preparation for Inter-RAT Inter-RAT Inter-Cell
Incoming Inter-RAT Inter-Cell Handovers]/[CH361:Incoming
Inter-Cell Radio Handover Inter-RAT Inter-Cell Handover
Handover Measuremen Responses]
t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 236


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

6.1.2 UMTS Interoperations Report

Report Type
Simple Report

NE Type
3GRNC

Object Type
UCell Group

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

UMTS Number of none InterRAT -


Interoper Preparation Attempts Handover
ations for CS Outgoing Measuremen
Report Inter-RAT Handover t per cell
for Cell

Number of none InterRAT -


Successful Handover
Preparations for CS Measuremen
Outgoing Inter-RAT t per cell
Handover for Cell

VS.IRATHO.SuccR % InterRAT [Number of Successful


elocPrepOutCS.Cell. Handover Preparations for CS Outgoing
Rate Measuremen Inter-RAT Handover for Cell]/
t per cell [Number of Preparation
Attempts for CS Outgoing
Inter-RAT Handover for Cell]*
{100.00}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 237


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Number of CS none InterRAT -


Outgoing Inter-RAT Handover
Handover Attempts Measuremen
t per cell

Number of none InterRAT -


Successful CS Handover
Outgoing Inter-RAT Measuremen
Handovers for Cell t per cell

VS.IRATHO.SuccO % InterRAT [Number of Successful CS


utCS.Cell.Rate Handover Outgoing Inter-RAT
Measuremen Handovers for Cell]/[Number
t per cell of CS Outgoing Inter-RAT
Handover Attempts]*{100.00}

Number of PS none InterRAT -


Outgoing Inter-RAT Handover
Handover Attempts Measuremen
Initiated by RNC for t per cell
Cell

Number of none InterRAT -


Successful PS Handover
Outgoing Inter-RAT Measuremen
Handovers Initiated t per cell
by RNC for Cell

VS.IRATHO.SuccO % InterRAT [Number of Successful PS


utPSUNTRAN.Cell. Handover Outgoing Inter-RAT
Rate Measuremen Handovers Initiated by RNC
t per cell for Cell]/[Number of PS
Outgoing Inter-RAT Handover
Attempts Initiated by RNC for
Cell]*{100.00}

Number of none InterRAT -


Preparations for CS Handover
Incoming Inter-RAT Measuremen
Handover for Cell t per cell

Number of none InterRAT -


Successful Handover
preparations for CS Measuremen
Incoming Inter-RAT t per cell
Handovers for Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 238


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Success Rate of % InterRAT [Number of Successful


preparations for CS Handover preparations for CS Incoming
Incoming Inter-RAT Measuremen Inter-RAT Handovers for
Handovers for Cell t per cell Cell]/[Number of Preparations
for CS Incoming Inter-RAT
Handover for Cell]*{100}

Number of CS none InterRAT -


Incoming Inter-RAT Handover
Handover Attempts Measuremen
for Cell t per cell

Number of none InterRAT -


Successful CS Handover
Incoming Inter-RAT Measuremen
Handovers for Cell t per cell

Success Rate of CS % InterRAT [Number of Successful CS


Incoming Inter-RAT Handover Incoming Inter-RAT
Handovers for Cell Measuremen Handovers for Cell]/[Number
t per cell of CS Incoming Inter-RAT
Handover Attempts for Cell]*
{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

6.1.3 GSM CoRRM Report


Report Type
Simple Report

NE Type
2GBSC

Object Type
GCell Group

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 239


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

GSM H350M:Outgoing none Outgoing -


CoRRM Inter-RAT Inter-Cell Inter-RAT
Report Handover Requests Inter-Cell
(service based Handover
handover) Measuremen
t per Cell

H351M:Outgoing none Outgoing -


Inter-RAT Inter-Cell Inter-RAT
Handover Inter-Cell
Commands(service Handover
based handover) Measuremen
t per Cell

H352M:Failed none Outgoing -


Outgoing Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(service based Handover
handover) Measuremen
t per Cell

H350G:Outgoing none Outgoing -


Inter-RAT Inter-Cell Inter-RAT
Handover Requests Inter-Cell
(load based Handover
handover) Measuremen
t per Cell

H351G:Outgoing none Outgoing -


Inter-RAT Inter-Cell Inter-RAT
Handover Inter-Cell
Commands(load Handover
based handover) Measuremen
t per Cell

H352N:Number of none Outgoing -


Failed Outgoing Inter-RAT
Inter-RAT Inter-Cell Inter-Cell
Handovers (Target Handover
Cell Traffic Load Measuremen
Higher) t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 240


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

6.1.4 UMTS CoRRM Report

Report Type
Simple Report

NE Type
3GRNC

Object Type
UCell Group

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

UMTS Number of none InterRAT -


CoRRM Successful CS Handover
Report Outgoing Inter-RAT Measuremen
Handovers Based on t per cell
Load for Cell

Number of none InterRAT -


Preparation Attempts Handover
for CS Outgoing Measuremen
Inter-RAT Handover t per cell
Initiated by UTRAN
Based on Load for
Cell

Number of none InterRAT -


Successful Handover
Preparations for CS Measuremen
Outgoing Inter-RAT t per cell
Handover Initiated
by UTRAN Based on
Load for Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 241


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Number of none InterRAT -


Preparation Attempts Handover
for CS Outgoing Measuremen
Inter-RAT Handover t per cell
Based on RF
(Coverage, QoS, or
HCS) for Cell

Number of none InterRAT -


Successful Handover
Preparations for CS Measuremen
Outgoing Inter-RAT t per cell
Handover Based on
RF (Coverage, QoS,
or HCS) for Cell

Number of none InterRAT -


Successful CS Handover
Outgoing Inter-RAT Measuremen
Handovers Based on t per cell
Service Type for Cell

Number of none InterRAT -


Preparation Attempts Handover
for CS Outgoing Measuremen
Inter-RAT Handover t per cell
Based on Service
Type for Cell

Number of none InterRAT -


Successful Handover
Preparations for CS Measuremen
Outgoing Inter-RAT t per cell
Handover Based on
Service Type for Cell

Number of none InterRAT -


Successful CS Handover
Outgoing Inter-RAT Measuremen
Handovers Based on t per cell
Directed Retry for
Cell

Number of none InterRAT -


Preparation Attempts Handover
for CS Outgoing Measuremen
Inter-RAT Handover t per cell
Based on Directed
Retry for Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 242


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Number of none InterRAT -


Successful Handover
Preparations for CS Measuremen
Outgoing Inter-RAT t per cell
Handover Based on
Directed Retry for
Cell

Number of PS none InterRAT -


Outgoing Inter-RAT Handover
Handover Attempts Measuremen
Initiated by UTRAN t per cell
Based on Load for
Cell

Number of none InterRAT -


Successful PS Handover
Outgoing Inter-RAT Measuremen
Handovers Initiated t per cell
by UTRAN Based on
Load for Cell

Number of PS none InterRAT -


Outgoing Inter-RAT Handover
Handover Attempts Measuremen
Initiated by the RNC t per cell
Based on Service
Type for Cell

Number of none InterRAT -


Successful PS Handover
Outgoing Inter-RAT Measuremen
Handovers Initiated t per cell
by the RNC Based on
Service Type for Cell

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 243


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

6.1.5 GSM Power Sharing Report

Report Type
Simple Report

NE Type
2GBSC

Object Type
GCell Group

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

GSM GU1000:Number of none GU Power -


Power Times That GSM Sharing
Sharing Shares Power with Measuremen
Report UMTS t for TRX

GU1001:Number of none GU Power -


Times That GSM Sharing
Takes Power Back Measuremen
from UMTS t for TRX

GU1002:Total s GU Power -
Duration That GSM Sharing
Shares Power with Measuremen
UMTS t for TRX

GU1003:Total none GU Power -


Power That GSM Sharing
Shares with UMTS Measuremen
t for TRX

GU1004:Average milli GU Power -


Power that GSM watt Sharing
Shares with UMTS Measuremen
t for TRX

GU1005:Number of none GU Power -


GU Power Sharing Sharing
Periods Measuremen
t for TRX

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 244


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

GU1006:Total milli GU Power -


Remaining Shareable watt Sharing
Power of a GSM Measuremen
TRX t for TRX

GU1007:Average milli GU Power -


Remaining Shareable watt Sharing
Power of a GSM Measuremen
TRX t for TRX

GU1008:Number of none GU Power -


Times of Power Sharing
Insufficiency After Measuremen
GSM Shares Power t for TRX
with UMTS

GU1009:Number of none GU Power -


Timeslots that GSM Sharing
Shares Power with Measuremen
UMTS t for TRX

GU1010:GSM none GU Power -


Power Insufficiency Sharing
Rate After GSM Measuremen
Shares Power with t for TRX
UMTS

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

6.1.6 UMTS Power Sharing Report(RNC counter)

Report Type
Simple Report

NE Type
3GRNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 245


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

Object Type
UCell Group

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

UMTS Mean Non-HSDPA dBm Cell TX and -


Power Transmitted Carrier RX Power
Sharing Power for Cell Measuremen
Report t per cell
(RNC
counter) Maximum Non- dBm Cell TX and -
HSDPA Transmitted RX Power
Carrier Power for Measuremen
Cell t per cell

Minimum Non- dBm Cell TX and -


HSDPA Transmitted RX Power
Carrier Power for Measuremen
Cell t per cell

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

6.1.7 UMTS Power sharing Report(NodeB counter)

Report Type
Simple Report

NE Type
3GRNC

Object Type
UCell Group

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 246


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

UMTS VS.DataOutput.User bit/s HSDPA -


Power Data Measuremen
sharing ts per Local
Report Cell
(NodeB
counter) VS.PdschPwrRatio. per HSDPA -
Mean mill Measuremen
ts per Local
Cell

VS.PdschPwrRatio. per HSDPA -


Max mill Measuremen
ts per Local
Cell

VS.PdschPwrRatio. per HSDPA -


Min mill Measuremen
ts per Local
Cell

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

6.1.8 Success Rate of Preparation for Outgoing Inter-RAT Inter-Cell


Handover Analysis

Report Type
Simple Report

NE Type
2GBSC

Object Type
GCell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 247


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Success H352Ka:Failed none Outgoing -


Rate of Outgoing Inter-RAT Inter-RAT
Preparati Inter-Cell Handovers Inter-Cell
on for (Handover Request Handover
Outgoing Rejected) (OM Measuremen
Inter- Intervention) t per Cell
RAT
Inter- H352Kb:Failed none Outgoing -
Cell Outgoing Inter-RAT Inter-RAT
Handove Inter-Cell Handovers Inter-Cell
r (Handover Request Handover
Analysis Rejected) Measuremen
(Equipment Failure) t per Cell

H352Kc:Failed none Outgoing -


Outgoing Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(Handover Request Handover
Rejected) (No Radio Measuremen
Resource Available) t per Cell

H352Kd:Failed none Outgoing -


Outgoing Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(Handover Request Handover
Rejected) (Requested Measuremen
Terrestrial Resource t per Cell
Unavailable)

H352Ke:Failed none Outgoing -


Outgoing Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(Handover Request Handover
Rejected) (BSS not Measuremen
Equipped) t per Cell

H352Kf:Failed none Outgoing -


Outgoing Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(Handover Request Handover
Rejected) (Invalid Measuremen
Cell) t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 248


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

H352Kg:Failed none Outgoing -


Outgoing Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(Handover Request Handover
Rejected) (Requested Measuremen
Transcoding/Rate t per Cell
Adaption
Unavailable)

H352Kh:Failed none Outgoing -


Outgoing Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(Handover Request Handover
Rejected) (Circuit Measuremen
Pool Mismatch) t per Cell

H352Ki:Failed none Outgoing -


Outgoing Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(Handover Request Handover
Rejected) (Requested Measuremen
Speech Version t per Cell
Unavailable)

H352Kj:Failed none Outgoing -


Outgoing Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(Handover Request Handover
Rejected) (Ciphering Measuremen
Algorithm not t per Cell
Supported)

H352Kk:Failed none Outgoing -


Outgoing Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(Handover Request Handover
Rejected) (Terrestrial Measuremen
circuit already t per Cell
allocated)

H352Kl:Failed none Outgoing -


Outgoing Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(Handover Request Handover
Rejected) (Invalid Measuremen
Message) t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 249


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

H352Km:Failed none Outgoing -


Outgoing Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(Handover Request Handover
Rejected) (Protocol Measuremen
Error between BSS t per Cell
and MSC)

H352Kn:Failed none Outgoing -


Outgoing Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(Handover Request Handover
Rejected) (Other Measuremen
Causes) t per Cell

H352Ha:Failed none Outgoing -


Outgoing Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(Clear Commands Handover
Sent By MSC) Measuremen
(Radio Interface t per Cell
Message Failure)

H352Hb:Failed none Outgoing -


Outgoing Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(Clear Commands Handover
Sent By MSC) Measuremen
(Radio Interface t per Cell
Failure)

H352Hc:Failed none Outgoing -


Outgoing Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(Clear Commands Handover
Sent By MSC) (OM Measuremen
Intervention) t per Cell

H352Hd:Failed none Outgoing -


Outgoing Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(Clear Commands Handover
Sent By MSC) Measuremen
(Equipment Failure) t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 250


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

H352He:Failed none Outgoing -


Outgoing Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(Clear Commands Handover
Sent By MSC) Measuremen
(Preemption) t per Cell

H352Hf:Failed none Outgoing -


Outgoing Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(Clear Commands Handover
Sent By MSC) Measuremen
(Invalid Message) t per Cell

H352Hg:Failed none Outgoing -


Outgoing Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(Clear Commands Handover
Sent By MSC) Measuremen
(Protocol Error t per Cell
between BSS and
MSC)

H352Hh:Failed none Outgoing -


Outgoing Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(Clear Commands Handover
Sent By MSC) (Other Measuremen
Causes) t per Cell

H352G:Failed none Outgoing -


Outgoing Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(A Interface Failure) Handover
Measuremen
t per Cell

H352L:Failed none Outgoing -


Outgoing Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(T7 Expired) Handover
Measuremen
t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 251


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

6.1.9 Success Rate of Preparation for Outgoing Inter-RAT Inter-Cell


Radio Handover Analysis

Report Type
Simple Report

NE Type
2GBSC

Object Type
GCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Success H352Da:Failed none Outgoing -


Rate of Outgoing Inter-RAT Inter-RAT
Preparati Inter-Cell Handovers Inter-Cell
on for (Reconnection to Old Handover
Outgoing Channels) Measuremen
Inter- (Abnormal Release, t per Cell
RAT Unspecified)
Inter-
Cell H352Db:Failed none Outgoing -
Radio Outgoing Inter-RAT Inter-RAT
Handove Inter-Cell Handovers Inter-Cell
r (Reconnection to Old Handover
Analysis Channels) Measuremen
(Abnormal Release, t per Cell
Channel
Unacceptable)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 252


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

H352Dc:Failed none Outgoing -


Outgoing Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(Reconnection to Old Handover
Channels) Measuremen
(Abnormal Release, t per Cell
Timer Expired)

H352Dd:Failed none Outgoing -


Outgoing Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(Reconnection to Old Handover
Channels) Measuremen
(Abnormal Release, t per Cell
No Activity on the
Radio Path)

H352De:Failed none Outgoing -


Outgoing Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(Reconnection to Old Handover
Channels) Measuremen
(Preemptive Release) t per Cell

H352Df:Failed none Outgoing -


Outgoing Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(Reconnection to Old Handover
Channels) (Handover Measuremen
Failed, Timing t per Cell
Advance out of
Range)

H352Dg:Failed none Outgoing -


Outgoing Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(Reconnection to Old Handover
Channels) (Channel Measuremen
Mode Unavailable) t per Cell

H352Dh:Failed none Outgoing -


Outgoing Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(Reconnection to Old Handover
Channels) Measuremen
(Frequency t per Cell
Unavailable)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 253


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

H352Di:Failed none Outgoing -


Outgoing Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(Reconnection to Old Handover
Channels) (Call Measuremen
Already Cleared) t per Cell

H352Dj:Failed none Outgoing -


Outgoing Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(Reconnection to Old Handover
Channels) Measuremen
(Semantically t per Cell
Incorrect Message)

H352Dk:Failed none Outgoing -


Outgoing Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(Reconnection to Old Handover
Channels) (Invalid Measuremen
Mandatory t per Cell
Information)

H352Dl:Failed none Outgoing -


Outgoing Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(Reconnection to Old Handover
Channels) (Message Measuremen
Type Non-existent or t per Cell
Not Implemented)

H352Dm:Failed none Outgoing -


Outgoing Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(Reconnection to Old Handover
Channels) (Message Measuremen
Type Not t per Cell
Compatible with
Protocol State)

H352Dn:Failed none Outgoing -


Outgoing Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(Reconnection to Old Handover
Channels) Measuremen
(Conditional IE t per Cell
Error)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 254


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

H352Do:Failed none Outgoing -


Outgoing Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(Reconnection to Old Handover
Channels) (No Cell Measuremen
Allocation t per Cell
Available)

H352Dp:Failed none Outgoing -


Outgoing Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(Reconnection to Old Handover
Channels) (Protocol Measuremen
Error Unspecified) t per Cell

H352Dq:Failed none Outgoing -


Outgoing Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(Reconnection to Old Handover
Channels) (Other Measuremen
Causes) t per Cell

H352C:Failed none Outgoing -


Outgoing Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(T8 Expired) Handover
Measuremen
t per Cell

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

6.1.10 Success Rate of Preparation for Incoming Inter-RAT Inter-


Cell Handover Analysis

Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 255


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

NE Type
2GBSC

Object Type
GCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Success H362J:Failed none Incoming -


Rate of Incoming Inter-RAT Inter-RAT
Preparati Inter-Cell Handovers Inter-Cell
on for (Invalid Message) Handover
Incoming Measuremen
Inter- t per Cell
RAT
Inter- H3620A:Failed none Incoming -
Cell Incoming Inter-RAT Inter-RAT
Handove Inter-Cell Handovers Inter-Cell
r (No Channel Handover
Analysis Available) (SDCCH) Measuremen
t per Cell

H3629A:Failed none Incoming -


Incoming Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(No Channel Handover
Available) (TCH) Measuremen
t per Cell

H362E:Failed none Incoming -


Incoming Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(CIC Unavailable) Handover
Measuremen
t per Cell

H362F:Failed none Incoming -


Incoming Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(CIC Allocated) Handover
Measuremen
t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 256


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

H362B:Failed none Incoming -


Incoming Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(Terrestrial Resource Handover
Request Failed) Measuremen
t per Cell

H362L:Failed none Incoming -


Incoming Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(Requested Speech Handover
Version Unavailable) Measuremen
t per Cell

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

6.1.11 Success Rate of Preparation for Incoming Inter-RAT Inter-


Cell Radio Handover Analysis

Report Type
Simple Report

NE Type
2GBSC

Object Type
GCell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 257


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Success H362H:Failed none Incoming -


Rate of Incoming Inter-RAT Inter-RAT
Preparati Inter-Cell Handovers Inter-Cell
on for (Clear Commands Handover
Incoming Sent By MSC) Measuremen
Inter- t per Cell
RAT
Inter- H3620C:Failed none Incoming -
Cell Incoming Inter-RAT Inter-RAT
Radio Inter-Cell Handovers Inter-Cell
Handove (Timer Expired) Handover
r (SDCCH) Measuremen
Analysis t per Cell

H3629Cb:Failed none Incoming -


Incoming Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(Timer Expired) Handover
(TCH) (Signaling Measuremen
Channel) t per Cell

H3629Ca:Failed none Incoming -


Incoming Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(Timer Expired) Handover
(TCH) (Traffic Measuremen
Channel) t per Cell

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

6.1.12 Success Rate of Preparations for CS Outgoing Inter-RAT


Handover for Cell Analysis

Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 258


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

NE Type
3GRNC

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Success Number of Failed none InterRAT -


Rate of Preparations for CS Handover
Preparati Outgoing Inter-RAT Measuremen
ons for Handover for Cell t per cell
CS (TRELOCalloc
Outgoing expiry)
Inter-
RAT Number of Failed none InterRAT -
Handove Preparations for CS Handover
r for Cell Outgoing Inter-RAT Measuremen
Analysis Handover for Cell t per cell
(Relocation Failure
in Target CN/RNC or
Target System)

Number of Failed none InterRAT -


Preparations for CS Handover
Outgoing Inter-RAT Measuremen
Handover for Cell t per cell
(Relocation not
supported in Target
RNC or Target
system)

Number of Failed none InterRAT -


Preparations for CS Handover
Outgoing Inter-RAT Measuremen
Handover for Cell t per cell
(Traffic Load In The
Target Cell Higher
Than In The Source
Cell)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 259


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Number of Failed none InterRAT -


Preparations for CS Handover
Outgoing Inter-RAT Measuremen
Handover for Cell t per cell
(No Resource
Available)

Number of Failed none InterRAT -


Preparations for CS Handover
Outgoing Inter-RAT Measuremen
Handover for Cell t per cell
(Unknown Target
RNC)

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

6.1.13 Success Rate of CS Outgoing Inter-RAT Handovers for Cell


Analysis

Report Type
Simple Report

NE Type
3GRNC

Object Type
UCell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 260


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Success Number of Failed CS none InterRAT -


Rate of Outgoing Inter-RAT Handover
CS Handovers for Cell Measuremen
Outgoing (Configuration t per cell
Inter- Unsupported)
RAT
Handove Number of Failed CS none InterRAT -
rs for Outgoing Inter-RAT Handover
Cell Handovers for Cell Measuremen
Analysis (Physical Channel t per cell
Failure)

Number of Times none InterRAT -


that the Timer Handover
Waiting for Iu Measuremen
Release Command t per cell
Expires in CS
Outgoing Inter-RAT
Handover for Cell

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

6.1.14 Success Rate of PS Outgoing Inter-RAT Handover Initiated


by RNC for Cell Analysis

Report Type
Simple Report

NE Type
3GRNC

Object Type
UCell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 261


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Success Number of Times none InterRAT -


Rate of that the Timer Handover
PS Waiting for Iu Measuremen
Outgoing Release Command t per cell
Inter- Expires in PS
RAT Outgoing Inter-RAT
Handove Handover Initiated
r Initiated by RNC for Cell
by RNC
for Cell Number of Failed PS none InterRAT -
Analysis Outgoing Inter-RAT Handover
Handovers Initiated Measuremen
by RNC t per cell
(Configuration
unsupported)

Number of Failed PS none InterRAT -


Outgoing Inter-RAT Handover
Handovers Initiated Measuremen
by RNC (Physical t per cell
Channel Failure)

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

6.1.15 Success Rate of Preparations for CS Incoming Inter-RAT


Handovers for Cell Analysis

Report Type
Simple Report

NE Type
3GRNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 262


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Success Number of Failed none InterRAT -


Rate of Preparations for CS Handover
Preparati Incoming Inter-RAT Measuremen
ons for Handover t per cell
CS (Relocation failure in
Incoming target CN/RNC or
Inter- target system)
RAT
Handove Number of Failed none InterRAT -
rs for Preparations for CS Handover
Cell Incoming Inter-RAT Measuremen
Analysis Handover t per cell
(Relocation not
supported in target
RNC or target
system)

Number of Failed none InterRAT -


Preparations for CS Handover
Incoming Inter-RAT Measuremen
Handover (No t per cell
resource available)

Number of Failed none InterRAT -


Preparations for CS Handover
Incoming Inter-RAT Measuremen
Handover (Traffic t per cell
Load In The Target
Cell Higher Than In
The Source Cell)

Number of CS none InterRAT -


Incoming Inter-RAT Handover
Handover Measuremen
Preparation Failures t per cell
for Cell (Iu
RELEASE
COMMAND
Received)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 263


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

6.1.16 Success Rate of CS Incoming Inter-RAT Handovers for Cell


Analysis

Report Type
Simple Report

NE Type
3GRNC

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Success Number of Failed CS none InterRAT -


Rate of Inter-RAT Incoming Handover
CS Handovers Due to No Measuremen
Incoming Response from UE t per cell
Inter- for Cell
RAT
Handove
rs for
Cell
Analysis

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 264


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

6.2 GU Interoperations Report


Report Type
Combined Report

Simple Report(s) List


l GSM Interoperations Report
l UMTS Interoperations Report

GSM Interoperations Report

NE Type
2GBSC

Object Type
GCell Group

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

GSM CH350:Outgoing none Outgoing -


Interoper Inter-RAT Inter-Cell Inter-RAT
ations Handover Requests Inter-Cell
Report Handover
Measuremen
t per Cell

CH351:Outgoing none Outgoing -


Inter-RAT Inter-Cell Inter-RAT
Handover Inter-Cell
Commands Handover
Measuremen
t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 265


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

CH353:Successful none Outgoing -


Outgoing Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
Handover
Measuremen
t per Cell

GSM Voice none Outgoing [CH351:Outgoing Inter-RAT


Outgoing Inter-RAT Inter-RAT Inter-Cell Handover
Inter-Cell Handover Inter-Cell Commands]/
Preparation Success Handover [CH350:Outgoing Inter-RAT
Rate Measuremen Inter-Cell Handover Requests]
t per Cell

GSM Voice none Outgoing [CH353:Successful Outgoing


Outgoing Inter-RAT Inter-RAT Inter-RAT Inter-Cell
Inter-Cell Handover Inter-Cell Handovers]/[CH351:Outgoing
Success Rate Handover Inter-RAT Inter-Cell Handover
Measuremen Commands]
t per Cell

CH360:Incoming none Incoming -


Inter-RAT Inter-Cell Inter-RAT
Handover Requests Inter-Cell
Handover
Measuremen
t per Cell

CH361:Incoming none Incoming -


Inter-RAT Inter-Cell Inter-RAT
Handover Responses Inter-Cell
Handover
Measuremen
t per Cell

CH363:Successful none Incoming -


Incoming Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
Handover
Measuremen
t per Cell

Success Rate of % Incoming [CH361:Incoming Inter-RAT


Preparation for Inter-RAT Inter-Cell Handover
Incoming Inter-RAT Inter-Cell Responses]/[CH360:Incoming
Inter-Cell Handover Handover Inter-RAT Inter-Cell Handover
Measuremen Requests]
t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 266


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Success Rate of % Incoming [CH363:Successful Incoming


Preparation for Inter-RAT Inter-RAT Inter-Cell
Incoming Inter-RAT Inter-Cell Handovers]/[CH361:Incoming
Inter-Cell Radio Handover Inter-RAT Inter-Cell Handover
Handover Measuremen Responses]
t per Cell

UMTS Interoperations Report

NE Type
3GRNC

Object Type
UCell Group

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

UMTS Number of none InterRAT -


Interoper Preparation Attempts Handover
ations for CS Outgoing Measuremen
Report Inter-RAT Handover t per cell
for Cell

Number of none InterRAT -


Successful Handover
Preparations for CS Measuremen
Outgoing Inter-RAT t per cell
Handover for Cell

VS.IRATHO.SuccR % InterRAT [Number of Successful


elocPrepOutCS.Cell. Handover Preparations for CS Outgoing
Rate Measuremen Inter-RAT Handover for Cell]/
t per cell [Number of Preparation
Attempts for CS Outgoing
Inter-RAT Handover for Cell]*
{100.00}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 267


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Number of CS none InterRAT -


Outgoing Inter-RAT Handover
Handover Attempts Measuremen
t per cell

Number of none InterRAT -


Successful CS Handover
Outgoing Inter-RAT Measuremen
Handovers for Cell t per cell

VS.IRATHO.SuccO % InterRAT [Number of Successful CS


utCS.Cell.Rate Handover Outgoing Inter-RAT
Measuremen Handovers for Cell]/[Number
t per cell of CS Outgoing Inter-RAT
Handover Attempts]*{100.00}

Number of PS none InterRAT -


Outgoing Inter-RAT Handover
Handover Attempts Measuremen
Initiated by RNC for t per cell
Cell

Number of none InterRAT -


Successful PS Handover
Outgoing Inter-RAT Measuremen
Handovers Initiated t per cell
by RNC for Cell

VS.IRATHO.SuccO % InterRAT [Number of Successful PS


utPSUNTRAN.Cell. Handover Outgoing Inter-RAT
Rate Measuremen Handovers Initiated by RNC
t per cell for Cell]/[Number of PS
Outgoing Inter-RAT Handover
Attempts Initiated by RNC for
Cell]*{100.00}

Number of none InterRAT -


Preparations for CS Handover
Incoming Inter-RAT Measuremen
Handover for Cell t per cell

Number of none InterRAT -


Successful Handover
preparations for CS Measuremen
Incoming Inter-RAT t per cell
Handovers for Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 268


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Success Rate of % InterRAT [Number of Successful


preparations for CS Handover preparations for CS Incoming
Incoming Inter-RAT Measuremen Inter-RAT Handovers for
Handovers for Cell t per cell Cell]/[Number of Preparations
for CS Incoming Inter-RAT
Handover for Cell]*{100}

Number of CS none InterRAT -


Incoming Inter-RAT Handover
Handover Attempts Measuremen
for Cell t per cell

Number of none InterRAT -


Successful CS Handover
Incoming Inter-RAT Measuremen
Handovers for Cell t per cell

Success Rate of CS % InterRAT [Number of Successful CS


Incoming Inter-RAT Handover Incoming Inter-RAT
Handovers for Cell Measuremen Handovers for Cell]/[Number
t per cell of CS Incoming Inter-RAT
Handover Attempts for Cell]*
{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

6.3 GU CoRRM Report


Report Type
Combined Report

Simple Report(s) List


l GSM CoRRM Report
l UMTS CoRRM Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 269


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

GSM CoRRM Report

NE Type
2GBSC

Object Type
GCell Group

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

GSM H350M:Outgoing none Outgoing -


CoRRM Inter-RAT Inter-Cell Inter-RAT
Report Handover Requests Inter-Cell
(service based Handover
handover) Measuremen
t per Cell

H351M:Outgoing none Outgoing -


Inter-RAT Inter-Cell Inter-RAT
Handover Inter-Cell
Commands(service Handover
based handover) Measuremen
t per Cell

H352M:Failed none Outgoing -


Outgoing Inter-RAT Inter-RAT
Inter-Cell Handovers Inter-Cell
(service based Handover
handover) Measuremen
t per Cell

H350G:Outgoing none Outgoing -


Inter-RAT Inter-Cell Inter-RAT
Handover Requests Inter-Cell
(load based Handover
handover) Measuremen
t per Cell

H351G:Outgoing none Outgoing -


Inter-RAT Inter-Cell Inter-RAT
Handover Inter-Cell
Commands(load Handover
based handover) Measuremen
t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 270


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

H352N:Number of none Outgoing -


Failed Outgoing Inter-RAT
Inter-RAT Inter-Cell Inter-Cell
Handovers (Target Handover
Cell Traffic Load Measuremen
Higher) t per Cell

UMTS CoRRM Report

NE Type
3GRNC

Object Type
UCell Group

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

UMTS Number of none InterRAT -


CoRRM Successful CS Handover
Report Outgoing Inter-RAT Measuremen
Handovers Based on t per cell
Load for Cell

Number of none InterRAT -


Preparation Attempts Handover
for CS Outgoing Measuremen
Inter-RAT Handover t per cell
Initiated by UTRAN
Based on Load for
Cell

Number of none InterRAT -


Successful Handover
Preparations for CS Measuremen
Outgoing Inter-RAT t per cell
Handover Initiated
by UTRAN Based on
Load for Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 271


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Number of none InterRAT -


Preparation Attempts Handover
for CS Outgoing Measuremen
Inter-RAT Handover t per cell
Based on RF
(Coverage, QoS, or
HCS) for Cell

Number of none InterRAT -


Successful Handover
Preparations for CS Measuremen
Outgoing Inter-RAT t per cell
Handover Based on
RF (Coverage, QoS,
or HCS) for Cell

Number of none InterRAT -


Successful CS Handover
Outgoing Inter-RAT Measuremen
Handovers Based on t per cell
Service Type for Cell

Number of none InterRAT -


Preparation Attempts Handover
for CS Outgoing Measuremen
Inter-RAT Handover t per cell
Based on Service
Type for Cell

Number of none InterRAT -


Successful Handover
Preparations for CS Measuremen
Outgoing Inter-RAT t per cell
Handover Based on
Service Type for Cell

Number of none InterRAT -


Successful CS Handover
Outgoing Inter-RAT Measuremen
Handovers Based on t per cell
Directed Retry for
Cell

Number of none InterRAT -


Preparation Attempts Handover
for CS Outgoing Measuremen
Inter-RAT Handover t per cell
Based on Directed
Retry for Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 272


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Number of none InterRAT -


Successful Handover
Preparations for CS Measuremen
Outgoing Inter-RAT t per cell
Handover Based on
Directed Retry for
Cell

Number of PS none InterRAT -


Outgoing Inter-RAT Handover
Handover Attempts Measuremen
Initiated by UTRAN t per cell
Based on Load for
Cell

Number of none InterRAT -


Successful PS Handover
Outgoing Inter-RAT Measuremen
Handovers Initiated t per cell
by UTRAN Based on
Load for Cell

Number of PS none InterRAT -


Outgoing Inter-RAT Handover
Handover Attempts Measuremen
Initiated by the RNC t per cell
Based on Service
Type for Cell

Number of none InterRAT -


Successful PS Handover
Outgoing Inter-RAT Measuremen
Handovers Initiated t per cell
by the RNC Based on
Service Type for Cell

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 273


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

6.4 GU Power Sharing Report


Report Type
Combined Report

Simple Report(s) List


l GSM Power Sharing Report
l UMTS Power Sharing Report(RNC counter)
l UMTS Power sharing Report(NodeB counter)

GSM Power Sharing Report

NE Type
2GBSC

Object Type
GCell Group

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

GSM GU1000:Number of none GU Power -


Power Times That GSM Sharing
Sharing Shares Power with Measuremen
Report UMTS t for TRX

GU1001:Number of none GU Power -


Times That GSM Sharing
Takes Power Back Measuremen
from UMTS t for TRX

GU1002:Total s GU Power -
Duration That GSM Sharing
Shares Power with Measuremen
UMTS t for TRX

GU1003:Total none GU Power -


Power That GSM Sharing
Shares with UMTS Measuremen
t for TRX

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 274


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

GU1004:Average milli GU Power -


Power that GSM watt Sharing
Shares with UMTS Measuremen
t for TRX

GU1005:Number of none GU Power -


GU Power Sharing Sharing
Periods Measuremen
t for TRX

GU1006:Total milli GU Power -


Remaining Shareable watt Sharing
Power of a GSM Measuremen
TRX t for TRX

GU1007:Average milli GU Power -


Remaining Shareable watt Sharing
Power of a GSM Measuremen
TRX t for TRX

GU1008:Number of none GU Power -


Times of Power Sharing
Insufficiency After Measuremen
GSM Shares Power t for TRX
with UMTS

GU1009:Number of none GU Power -


Timeslots that GSM Sharing
Shares Power with Measuremen
UMTS t for TRX

GU1010:GSM none GU Power -


Power Insufficiency Sharing
Rate After GSM Measuremen
Shares Power with t for TRX
UMTS

UMTS Power Sharing Report(RNC counter)

NE Type
3GRNC

Object Type
UCell Group

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 275


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

UMTS Mean Non-HSDPA dBm Cell TX and -


Power Transmitted Carrier RX Power
Sharing Power for Cell Measuremen
Report t per cell
(RNC
counter) Maximum Non- dBm Cell TX and -
HSDPA Transmitted RX Power
Carrier Power for Measuremen
Cell t per cell

Minimum Non- dBm Cell TX and -


HSDPA Transmitted RX Power
Carrier Power for Measuremen
Cell t per cell

UMTS Power sharing Report(NodeB counter)

NE Type
3GRNC

Object Type
UCell Group

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

UMTS VS.DataOutput.User bit/s HSDPA -


Power Data Measuremen
sharing ts per Local
Report Cell
(NodeB
counter) VS.PdschPwrRatio. per HSDPA -
Mean mill Measuremen
ts per Local
Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 276


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 6 GU SingleRAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.PdschPwrRatio. per HSDPA -


Max mill Measuremen
ts per Local
Cell

VS.PdschPwrRatio. per HSDPA -


Min mill Measuremen
ts per Local
Cell

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 277


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 7 WiMAX RAN Performance Report

7 WiMAX RAN Performance Report

About This Chapter

7.1 BTS performance Report

7.2 Carrier Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 278


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 7 WiMAX RAN Performance Report

7.1 BTS performance Report

7.1.1 BS performance test Report

Report Type
Simple Report

NE Type
BWA

Object Type
BWA

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

BS The failure times due times BS -


performa to UL transmission performance
nce test resource limited test

The failure times due times BS -


to DL transmission performance
resource limited test

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

7.2 Carrier Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 279


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 7 WiMAX RAN Performance Report

7.2.1 idle mode performance test Report

Report Type
Simple Report

NE Type
BWA

Object Type
BWA Carrier

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

idle Times of MS- times idle mode -


mode Initiated Entry to Idle performance
performa Mode test
nce test
Times of Successful times idle mode -
MS-Initiated Entry to performance
Idle Mode test

Times of BS- times idle mode -


Initiated Entry to Idle performance
Mode test

Times of Successful times idle mode -


BS-Initiated Entry to performance
Idle Mode test

Times When the MS times idle mode -


Rejects BS-Initiated performance
Entry to Idle Mode test

BS receive paging times idle mode -


response times performance
test

Times of Normal times idle mode -


Location Update performance
test

Times of Location times idle mode -


Update in Power-off performance
Mode test

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 280


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 7 WiMAX RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Times of Successful times idle mode -


Location Update performance
test

Times of Network times idle mode -


Re-Entry from Idle performance
Mode test

Times of Successful times idle mode -


Network Re-Entry performance
from Idle Mode test

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

7.2.2 link quality performance test Report

Report Type
Simple Report

NE Type
BWA

Object Type
BWA Carrier

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

link Number of DL numb link quality -


quality Unicast SDUs on er performance
performa Carrier test
nce test

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 281


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 7 WiMAX RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

DL Unicast Traffic byte link quality -


on Carrier performance
test

Number of UL numb link quality -


Unicast PDUs on er performance
Carrier test

UL Unicast Traffic byte link quality -


on Carrier performance
test

Total UL Bandwidth byte link quality -


Allocated performance
test

Number of DL numb link quality -


Discarded PDUs on er performance
Carrier test

Number of UL numb link quality -


Discarded Packets on er performance
Carrier test

Number of byte link quality -


Retransmitted Bytes performance
Required by BS test
(ARQ Enabled)

Number of byte link quality -


Retransmitted Bytes performance
Required by MS test
(ARQ Enabled)

Number of DL numb link quality -


Broadcast Packets er performance
test

DL Broadcast Traffic byte link quality -


performance
test

Total Number of times link quality -


HARQ performance
Retransmission test
Times

Total Number of times link quality -


HARQ Transmission performance
Times test

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 282


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 7 WiMAX RAN Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

7.2.3 handover performance test Report

Report Type
Simple Report

NE Type
BWA

Object Type
BWA Carrier

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

handover Number of MS- times handover -


performa Initiated Handover performance
nce test Requests test

Times of Successful times handover -


Handover Responses performance
from BS test

Times of Handover times handover -


Execution Triggered performance
by MS test

Number of BS- times handover -


Initiated Handover performance
Requests test

Times of Handover times handover -


Cancellation performance
Initiated by MS test

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 283


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 7 WiMAX RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Number of Incoming times handover -


Handover Requests performance
test

Times of times handover -


Successfully performance
Responding to test
Incoming Handover

Times of Ready times handover -


Incoming Handover performance
Execution test

Number of Ready times handover -


Incoming Handover performance
Ranging Requests test

Number of Unready times handover -


Incoming Handover performance
Ranging Requests test

Times of times handover -


Successfully performance
Responding to test
Incoming Handover
Ranging

Times of Completing times handover -


Incoming Handover performance
test

Number of Incoming times handover -


Handover Context performance
Requests test

Number of times handover -


Successful Context performance
Requests for test
Incoming Handover

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 284


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 7 WiMAX RAN Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

7.2.4 network entry performance test Report

Report Type
Simple Report

NE Type
BWA

Object Type
BWA Carrier

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

network Times of Receiving times network -


entry Initial Ranging entry
performa CDMA Code by BS performance
nce test test

Times of Receiving times network -


Periodic Ranging entry
CDMA Code by BS performance
test

Times of Receiving times network -


Handover Ranging entry
CDMA Code by BS performance
test

Times of Responding times network -


to Ranging CDMA entry
Code with Success performance
test

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 285


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 7 WiMAX RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Times of Responding times network -


to Ranging CDMA entry
Code with Continue performance
test

ranging CDMA code times network -


response abort times entry
performance
test

Number of Initial times network -


Network Entry entry
Requests performance
test

Successful Initial times network -


Ranging Times entry
performance
test

Number of Basic times network -


Capability entry
Negotiation performance
Requests test

Times of Successful times network -


Basic Capability entry
Negotiation by GW performance
test

Times of Successful times network -


Basic Capability entry
Negotiation performance
test

Number of times network -


Registration entry
Requests from MS performance
test

Times of Successful times network -


Registration by GW entry
performance
test

Times of Successful times network -


Registration for entry
Initial Network Entry performance
test

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 286


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 7 WiMAX RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Number of Service times network -


Flow Establishment entry
Requests performance
test

Times of Successful times network -


Service Flow entry
Establishment performance
test

service flow setup times network -


failure due to entry
overload control performance
test

Times of MS times network -


Authorization in entry
Initial Network Entry performance
test

Times of Successful times network -


MS Authorization in entry
Initial Network Entry performance
test

Times of MS- times network -


Initiated Re- entry
Authorization performance
test

Times of Successful times network -


MS-Initiated Re- entry
Authorization performance
test

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 287


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 7 WiMAX RAN Performance Report

7.2.5 network detach performance test Report

Report Type
Simple Report

NE Type
BWA

Object Type
BWA Carrier

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

network Times of times network -


detach Deregistration due to detach
performa Air Link Failure performance
nce test test

Times of times network -


Deregistration detach
Initiated by MS performance
test

Times of times network -


Deregistration detach
Initiated by GW performance
test

Times of times network -


Deregistration due to detach
OM performance
test

Times of times network -


Deregistration due to detach
Handover Failure performance
test

Times of times network -


Deregistration due to detach
Other Causes performance
test

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 288


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 7 WiMAX RAN Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

7.2.6 throughput performance test Report

Report Type
Simple Report

NE Type
BWA

Object Type
BWA Carrier

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

throughp uplink UGS byte throughput -


ut throughput performance
performa test
nce test
uplink ERTPS byte throughput -
throughput performance
test

uplink RTPS byte throughput -


throughput performance
test

uplink NRTPS byte throughput -


throughput performance
test

uplink BE byte throughput -


throughput performance
test

downlink UGS byte throughput -


throughput performance
test

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 289


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 7 WiMAX RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

downlink ERTPS byte throughput -


throughput performance
test

downlink RTPS byte throughput -


throughput performance
test

downlink NRTPS byte throughput -


throughput performance
test

downlink BE byte throughput -


throughput performance
test

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

7.2.7 carrier load performance test Report

Report Type
Simple Report

NE Type
BWA

Object Type
BWA Carrier

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 290


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 7 WiMAX RAN Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

carrier Maximum Number numb carrier load -


load of Online Users er performance
performa test
nce test
Minimum Number of numb carrier load -
Online Users er performance
test

Number of Slots numb carrier load -


Occupied by UL er performance
Common Channel test

Number of Slots numb carrier load -


Occupied by DL er performance
Broadcast Channel test

Number of Slots numb carrier load -


Occupied by UL er performance
Basic Channel test

Number of Slots numb carrier load -


Occupied by DL er performance
Basic Channel test

Number of Slots numb carrier load -


Occupied by UL er performance
Primary Channel test

Number of Slots numb carrier load -


Occupied by DL er performance
Primary Channel test

Number of Slots numb carrier load -


Occupied by DL er performance
Traffic Channel test

Number of Slots numb carrier load -


Occupied by UL er performance
Traffic Channel test

Total Length of UL byte carrier load -


SDUs on MAC Layer performance
test

Total Length of UL byte carrier load -


PDUs on MAC Layer performance
test

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 291


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 7 WiMAX RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Total Length of DL byte carrier load -


SDUs on MAC Layer performance
test

Total Length of DL byte carrier load -


PDUs on MAC Layer performance
test

Number of DL Slots numb carrier load -


Occupied on Carrier er performance
test

Number of UL Slots numb carrier load -


Occupied on Carrier er performance
test

Total Number of numb carrier load -


Slots Occupied on er performance
UL Partial Zone test

Total Number of numb carrier load -


Slots Occupied on er performance
DL Partial Zone test

Total Number of numb carrier load -


Slots Occupied on er performance
UL All Zone test

Total Number of numb carrier load -


Slots Occupied on er performance
DL All Zone test

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 292


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

8 CDMA BSS Performance Report

About This Chapter

8.1 CBSC-1x Performance Report

8.2 CDMA BSS EV-DORB Performance Report

8.3 CBSC-DO Performance Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 293


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

8.1 CBSC-1x Performance Report

8.1.1 CBSC NE Report

Overview of BSC Performance Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Overvie CS Call Setup % CS Call ([Successful CS Call Setups


w of BSC Success Ratio Setup [Times]]/[CS Attempts
Performa Performance [Times]])*{100}
nce Stat

PS Call Setup % PS Call Setup ([Successful PS Call Setups


Success Ratio Performance [Times]]/[PS Attempts
Stat [Times]])*{100}

CS Call Drop Ratio % CS Call Drop (([CS Call Drops (Too many
Performance Erasure frames)[Times]]+[CS
Stat Call Drops (No reverse frame
received)[Times]]+[CS Call
Drops (Abis interface
abnormal)[Times]]+[CS Call
Drops (A2 interface abnormal)
[Times]]+[CS Call Drops
(Other causes)[Times]])/
([Successful CS Call Setups
[Times]]+[Successful CS
Incoming Hard HOs[Times]]))
*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 294


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

PS Call Drop Ratio % PS Call Drop (([PS Call Drops (Too many
Performance Erasure frames)[Times]]+[PS
Stat Call Drops (No reverse frame
received)[Times]]+[PS call
Drops (Abis interface
abnormal)[Times]]+[PS Call
Drops (A1 interface abnormal)
[Times]]+[PS Call Drops (PCF
failure)[Times]]+[PS Call
Drops (HHO failure)[Times]]+
[PS Call Drops (Other causes)
[Times]])/([Successful PS Call
Setups[Times]]+[PS
Successful Incoming Hard
HOs[Times]]))*{100}

TCH Congestion % TCH (([TCH Assignment Requests


Ratio Congestion [Times]]-[Successful TCH
Performance Assignments[Times]])/[TCH
Stat Assignment Requests[Times]])
*{100}

IntraBS Soft HO % Intra-BSC [Successful Intra-BS Soft Hos


Success Ratio Soft HO [Times]]/[Intra-BS Soft HO
Performance Requests[Times]]*{100}
Stat

InterBS Soft HO % Inter-BSC [Successful Inter-BS Soft Hos


Success Ratio Soft HO [Times]]/[Inter-BS Soft HO
Performance Requests[Times]]*{100}
Stat

Soft HO Ratio FCH % BSC Traffic ((([CE Traffic Density - FCH-


Performance IS95[Erl]]+[CE Traffic
Stat(FCH) Density - FCH-IS2000[Erl]])-
([Density of Traffic Carried on
TCH (Excluding HO) (FCH-
IS95)[Erl]]+[Density of Traffic
Carried on TCH (Excluding
HO) (FCH-IS2000)[Erl]]))/
([Density of Traffic Carried on
TCH (Excluding HO) (FCH-
IS95)[Erl]]+[Density of Traffic
Carried on TCH (Excluding
HO) (FCH-IS2000)[Erl]]))*
{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 295


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Density of Traffic Erl BSC Traffic -


Carried on TCH Performance
(Excluding HO) (CS- Stat(FCH)
FCH)[Erl]

Density of Traffic Erl BSC Traffic -


Carried on TCH Performance
(Excluding HO) (PS- Stat(FCH)
FCH)[Erl]

CE Traffic Density- Erl BSC Traffic -


PS SCH[Erl] Performance
Stat(Forward
SCH)

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Inter-BS Soft HO Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 296


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Inter-BS Failure Times times Inter-BSC [Inter-BS Soft HO Failures


Soft HO Soft HO (Radio resources unavailable)
Failure Performance [Times]]+[Inter-BS Soft HO
Analyse Stat Failures (Requested Abis
resources unavailable)[Times]]
+[Inter-BS Soft HO Failures
(Radio interface abnormal)
[Times]]+[Inter-BS Soft HO
Failures (MS rejected)[Times]]
+[Inter-BS Soft HO Failures
(A3 link setup failed)[Times]]+
[Inter-BS Soft HO Failures
(Other causes)[Times]]

Inter-BS Soft HO times Inter-BSC -


Failures (Radio Soft HO
resources Performance
unavailable)[Times] Stat

Inter-BS Soft HO times Inter-BSC -


Failures (Requested Soft HO
Abis resources Performance
unavailable)[Times] Stat

Inter-BS Soft HO times Inter-BSC -


Failures (Radio Soft HO
interface abnormal) Performance
[Times] Stat

Inter-BS Soft HO times Inter-BSC -


Failures (MS Soft HO
rejected)[Times] Performance
Stat

Inter-BS Soft HO times Inter-BSC -


Failures (A3 link Soft HO
setup failed)[Times] Performance
Stat

Inter-BS Soft HO times Inter-BSC -


Failures (Other Soft HO
causes)[Times] Performance
Stat

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 297


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

InterBS Soft HO % Inter-BSC [Successful Inter-BS Soft Hos


Success Ratio Soft HO [Times]]/[Inter-BS Soft HO
Performance Requests[Times]]*{100}
Stat

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Intra-BS Soft HO Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 298


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Intra-BS Failure Times times Intra-BSC [Intra-BS Soft HO Failures


Soft HO Soft HO (Radio resources unavailable)
Failure Performance [Times]]+[Intra-BS Soft HO
Analyse Stat Failures (Requested Abis
resources unavailable)[Times]]
+[Intra-BS Soft HO Failures
(Radio interface abnormal)
[Times]]+[Intra-BS Soft HO
Failures (MS rejected)[Times]]
+[Intra-BS Soft HO Failures
(Other causes)[Times]]

Intra-BS Soft HO times Intra-BSC -


Failures (Radio Soft HO
resources Performance
unavailable)[Times] Stat

Intra-BS Soft HO times Intra-BSC -


Failures (Requested Soft HO
Abis resources Performance
unavailable)[Times] Stat

Intra-BS Soft HO times Intra-BSC -


Failures (Radio Soft HO
interface abnormal) Performance
[Times] Stat

Intra-BS Soft HO times Intra-BSC -


Failures (MS Soft HO
rejected)[Times] Performance
Stat

Intra-BS Soft HO times Intra-BSC -


Failures (Other Soft HO
causes)[Times] Performance
Stat

IntraBS Soft HO % Intra-BSC [Successful Intra-BS Soft Hos


Success Ratio Soft HO [Times]]/[Intra-BS Soft HO
Performance Requests[Times]]*{100}
Stat

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 299


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

CS Call Drop Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

CS Call CS Call Drop Times times CS Call Drop [CS Call Drops (Too many
Drop Performance Erasure frames)[Times]]+[CS
Reason Stat Call Drops (No reverse frame
Analyse received)[Times]]+[CS Call
Drops (Abis interface
abnormal)[Times]]+[CS Call
Drops (A2 interface abnormal)
[Times]]+[CS Call Drops
(Other causes)[Times]]

CS Call Drops (Too times CS Call Drop -


many Erasure Performance
frames)[Times] Stat

CS Call Drops (No times CS Call Drop -


reverse frame Performance
received)[Times] Stat

CS Call Drops (Abis times CS Call Drop -


interface abnormal) Performance
[Times] Stat

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 300


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

CS Call Drops (A2 times CS Call Drop -


interface abnormal) Performance
[Times] Stat

CS Call Drops (Other times CS Call Drop -


causes)[Times] Performance
Stat

CS IS-95 Call Drops times CS Call Drop -


(HHO fail)[Times] Performance
Stat

CS IS-2000 Call times CS Call Drop -


Drops (HHO fail) Performance
[Times] Stat

CS Call Drop Ratio % CS Call Drop (([CS Call Drops (Too many
Performance Erasure frames)[Times]]+[CS
Stat Call Drops (No reverse frame
received)[Times]]+[CS Call
Drops (Abis interface
abnormal)[Times]]+[CS Call
Drops (A2 interface abnormal)
[Times]]+[CS Call Drops
(Other causes)[Times]])/
([Successful CS Call Setups
[Times]]+[Successful CS
Incoming Hard HOs[Times]]))
*{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

CS Call Setup Report

Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 301


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NE Type
CBSC

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

CS Call CS Attempts[Times] times CS Call -


Setup Setup
Failure Performance
Reason Stat
Analyse
CS Call Setup Failure times CS Call [CS A1 Interface Failures
Times Setup [Times]]+[CS Call Resource
Performance Allocation Failures[Times]]+
Stat [CS Reverse TCH Preamble
Acquisition Failures[Times]]+
[CS Radio Link Setup Failures
[Times]]+[CS Service Connect
Failures[Times]]

CS A1 Interface times CS Call -


Failures[Times] Setup
Performance
Stat

CS Call Resource times CS Call -


Allocation Failures Setup
[Times] Performance
Stat

CS Reverse TCH times CS Call -


Preamble Setup
Acquisition Failures Performance
[Times] Stat

CS Radio Link Setup times CS Call -


Failures[Times] Setup
Performance
Stat

CS Service Connect times CS Call -


Failures[Times] Setup
Performance
Stat

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 302


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

CS Call Setup % CS Call ([Successful CS Call Setups


Success Ratio Setup [Times]]/[CS Attempts
Performance [Times]])*{100}
Stat

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

PS Call Drop Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 303


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

PS Call PS Call Drop Times times PS Call Drop [PS Call Drops (Too many
Drop Performance Erasure frames)[Times]]+[PS
Reason Stat Call Drops (No reverse frame
Analyse received)[Times]]+[PS call
Drops (Abis interface
abnormal)[Times]]+[PS Call
Drops (A1 interface abnormal)
[Times]]+[PS Call Drops (PCF
failure)[Times]]+[PS Call
Drops (Other causes)[Times]]+
[PS Call Drops (HHO failure)
[Times]]

PS Call Drops (Too times PS Call Drop -


many Erasure Performance
frames)[Times] Stat

PS Call Drops (No times PS Call Drop -


reverse frame Performance
received)[Times] Stat

PS call Drops (Abis times PS Call Drop -


interface abnormal) Performance
[Times] Stat

PS Call Drops (A1 times PS Call Drop -


interface abnormal) Performance
[Times] Stat

PS Call Drops (PCF times PS Call Drop -


failure)[Times] Performance
Stat

PS Call Drops (Other times PS Call Drop -


causes)[Times] Performance
Stat

PS Call Drops (HHO times PS Call Drop -


failure)[Times] Performance
Stat

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 304


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

PS Call Drop Ratio % PS Call Drop (([PS Call Drops (Too many
Performance Erasure frames)[Times]]+[PS
Stat Call Drops (No reverse frame
received)[Times]]+[PS call
Drops (Abis interface
abnormal)[Times]]+[PS Call
Drops (A1 interface abnormal)
[Times]]+[PS Call Drops (PCF
failure)[Times]]+[PS Call
Drops (HHO failure)[Times]]+
[PS Call Drops (Other causes)
[Times]])/([Successful PS Call
Setups[Times]]+[PS
Successful Incoming Hard
HOs[Times]]))*{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

PS Call Setup Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 305


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

PS Call PS Attempts[Times] times PS Call Setup -


Setup Performance
Failure Stat
Reason
Analyse PS Call Setup Failure times PS Call Setup [PS A1 Interface Failures
Times Performance [Times]]+[PS Call Resource
Stat Allocation Failures[Times]]+
[PS Reverse TCH Preamble
Acquisition Failures[Times]]+
[PS Radio Link Setup Failures
[Times]]+[PS Service Connect
Failures[Times]]

PS A1 Interface times PS Call Setup -


Failures[Times] Performance
Stat

PS Call Resource times PS Call Setup -


Allocation Failures Performance
[Times] Stat

PS Reverse TCH times PS Call Setup -


Preamble Performance
Acquisition Failures Stat
[Times]

PS Radio Link Setup times PS Call Setup -


Failures[Times] Performance
Stat

PS Service Connect times PS Call Setup -


Failures[Times] Performance
Stat

PS Call Setup % PS Call Setup ([Successful PS Call Setups


Success Ratio Performance [Times]]/[PS Attempts
Stat [Times]])*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 306


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

SPU Load Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

SPU Density of Traffic Erl BSC Traffic -


Load Carried on TCH Performance
Report (Excluding HO) (CS- Stat(FCH)
FCH)[Erl]

Density of Traffic Erl BSC Traffic -


Carried on TCH Performance
(Excluding HO) (PS- Stat(FCH)
FCH)[Erl]

CE Traffic Density- Erl BSC Traffic -


PS SCH[Erl] Performance
Stat(Forward
SCH)

CE Traffic Density - Erl BSC Traffic -


Speech Service FCH Performance
[Erl] Stat(FCH)

CE Traffic Density - Erl BSC Traffic -


Packet Service FCH Performance
[Erl] Stat(FCH)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 307


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

WALSH Traffic Erl BSC Traffic -


Density-FCH[Erl] Performance
Stat(FCH)

Total Traffic Erl BSC Traffic [Density of Traffic Carried on


Performance TCH (Excluding HO) (CS-
Stat(FCH) FCH)[Erl]]+[Density of
Traffic Carried on TCH
(Excluding HO) (PS-FCH)
[Erl]]+[CE Traffic Density-PS
SCH[Erl]]

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

TCH Congestion Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 308


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

TCH TCH Congestion times TCH [TCH Assignment Failures


Congesti Times Congestion (WALSH shortage)[Times]]+
on Performance [TCH Assignment Failures
Reason Stat (Low forward power)[Times]]
Analyse +[TCH Assignment Failures
(Low reverse power)[Times]]+
[TCH Assignment Failures
(Channel shortage)[Times]]+
[TCH Assignment Failures
(Other causes)[Times]]

TCH Assignment times TCH -


Failures (WALSH Congestion
shortage)[Times] Performance
Stat

TCH Assignment times TCH -


Failures (Low Congestion
forward power) Performance
[Times] Stat

TCH Assignment times TCH -


Failures (Low Congestion
reverse power) Performance
[Times] Stat

TCH Assignment times TCH -


Failures (Channel Congestion
shortage)[Times] Performance
Stat

TCH Assignment times TCH -


Failures (Other Congestion
causes)[Times] Performance
Stat

TCH Congestion % TCH (([TCH Assignment Requests


Ratio Congestion [Times]]-[Successful TCH
Performance Assignments[Times]])/[TCH
Stat Assignment Requests[Times]])
*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 309


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

8.1.2 CBSC Carrier Report

ACH PCH Channel Usage Ratio Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSCVG3Pilot

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

PCH PCH Average Using none PCH Using -


Channel Ratio[%] Ratio
Usage Performance
Ratio Stat
TOPN
Report PCH Max Using none PCH Using -
Ratio[%] Ratio
Performance
Stat

PCH Overhead none PCH Using -


Message Using Ratio Ratio
[%] Performance
Stat

PCH Call Message none PCH Using -


Using Ratio[%] Ratio
Performance
Stat

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 310


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

PCH Non-call none PCH Using -


Message Using Ratio Ratio
[%] Performance
Stat

ACH ACH Average Using none ACH -


Channel Ratio[%] Performance
Usage Stat
Ratio
TOPN ACH Max Using none ACH -
Report Ratio[%] Performance
Stat

ACH Min Using none ACH -


Ratio[%] Performance
Stat

ACH Average none ACH -


Collision Ratio[%] Performance
Stat

ACH Max Collision none ACH -


Ratio[%] Performance
Stat

ACH Min Collision none ACH -


Ratio[%] Performance
Stat

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Inter-BS Soft HO Report

Report Type
Simple Report

NE Type
CBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 311


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Object Type
CBSC Carrier

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Inter-BS Failure Times times Performance [Inter-BS Soft HO Failures


Soft HO Stat of (Radio resources unavailable)
Failure Carrier Inter- [Times]]+[Inter-BS Soft HO
TopN BSC Soft HO Failures (Requested Abis
resources unavailable)[Times]]
+[Inter-BS Soft HO Failures
(Radio interface abnormal)
[Times]]+[Inter-BS Soft HO
Failures (MS rejected)[Times]]
+[Inter-BS Soft HO Failures
(A3 link setup failed)[Times]]+
[Inter-BS Soft HO Failures
(Other causes)[Times]]

InterBS Soft HO % Performance ([Successful Inter-BS Soft Hos


Success Ratio Stat of [Times]]/[Inter-BS Soft HO
Carrier Inter- Requests[Times]])*{100}
BSC Soft HO

Inter-BS Soft HO times Performance -


Failures (Radio Stat of
resources Carrier Inter-
unavailable)[Times] BSC Soft HO

Inter-BS Soft HO times Performance -


Failures (Requested Stat of
Abis resources Carrier Inter-
unavailable)[Times] BSC Soft HO

Inter-BS Soft HO times Performance -


Failures (Radio Stat of
interface abnormal) Carrier Inter-
[Times] BSC Soft HO

Inter-BS Soft HO times Performance -


Failures (MS Stat of
rejected)[Times] Carrier Inter-
BSC Soft HO

Inter-BS Soft HO times Performance -


Failures (A3 link Stat of
setup failed)[Times] Carrier Inter-
BSC Soft HO

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 312


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Inter-BS Soft HO times Performance -


Failures (Other Stat of
causes)[Times] Carrier Inter-
BSC Soft HO

Inter-BS Failure Times times Performance [Inter-BS Soft HO Failures


Soft HO Stat of (Radio resources unavailable)
Success Carrier Inter- [Times]]+[Inter-BS Soft HO
Ratio(%) BSC Soft HO Failures (Requested Abis
TopN resources unavailable)[Times]]
+[Inter-BS Soft HO Failures
(Radio interface abnormal)
[Times]]+[Inter-BS Soft HO
Failures (MS rejected)[Times]]
+[Inter-BS Soft HO Failures
(A3 link setup failed)[Times]]+
[Inter-BS Soft HO Failures
(Other causes)[Times]]

InterBS Soft HO % Performance ([Successful Inter-BS Soft Hos


Success Ratio Stat of [Times]]/[Inter-BS Soft HO
Carrier Inter- Requests[Times]])*{100}
BSC Soft HO

Inter-BS Soft HO times Performance -


Failures (Radio Stat of
resources Carrier Inter-
unavailable)[Times] BSC Soft HO

Inter-BS Soft HO times Performance -


Failures (Requested Stat of
Abis resources Carrier Inter-
unavailable)[Times] BSC Soft HO

Inter-BS Soft HO times Performance -


Failures (Radio Stat of
interface abnormal) Carrier Inter-
[Times] BSC Soft HO

Inter-BS Soft HO times Performance -


Failures (MS Stat of
rejected)[Times] Carrier Inter-
BSC Soft HO

Inter-BS Soft HO times Performance -


Failures (A3 link Stat of
setup failed)[Times] Carrier Inter-
BSC Soft HO

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 313


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Inter-BS Soft HO times Performance -


Failures (Other Stat of
causes)[Times] Carrier Inter-
BSC Soft HO

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Intra-BS Soft HO Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC Carrier

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 314


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Intra-BS Failure Times times Performance [Intra-BS Soft HO Failures


Soft HO Stat of (Radio resources unavailable)
Failure Carrier Soft [Times]]+[Intra-BS Soft HO
TopN HO Failures (Requested Abis
resources unavailable)[Times]]
+[Intra-BS Soft HO Failures
(Radio interface abnormal)
[Times]]+[Intra-BS Soft HO
Failures (MS rejected)[Times]]
+[Intra-BS Soft HO Failures
(Other causes)[Times]]

IntraBS Soft HO % Performance ([Successful Intra-BS Soft Hos


Success Ratio Stat of [Times]]/[Intra-BS Soft HO
Carrier Soft Requests[Times]])*{100}
HO

Intra-BS Soft HO times Performance -


Failures (Radio Stat of
resources Carrier Soft
unavailable)[Times] HO

Intra-BS Soft HO times Performance -


Failures (Requested Stat of
Abis resources Carrier Soft
unavailable)[Times] HO

Intra-BS Soft HO times Performance -


Failures (Radio Stat of
interface abnormal) Carrier Soft
[Times] HO

Intra-BS Soft HO times Performance -


Failures (MS Stat of
rejected)[Times] Carrier Soft
HO

Intra-BS Soft HO times Performance -


Failures (Other Stat of
causes)[Times] Carrier Soft
HO

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 315


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Intra-BS Failure Times times Performance [Intra-BS Soft HO Failures


Soft HO Stat of (Radio resources unavailable)
Success Carrier Soft [Times]]+[Intra-BS Soft HO
Ratio(%) HO Failures (Requested Abis
TopN resources unavailable)[Times]]
+[Intra-BS Soft HO Failures
(Radio interface abnormal)
[Times]]+[Intra-BS Soft HO
Failures (MS rejected)[Times]]
+[Intra-BS Soft HO Failures
(Other causes)[Times]]

IntraBS Soft HO % Performance ([Successful Intra-BS Soft Hos


Success Ratio Stat of [Times]]/[Intra-BS Soft HO
Carrier Soft Requests[Times]])*{100}
HO

Intra-BS Soft HO times Performance -


Failures (Radio Stat of
resources Carrier Soft
unavailable)[Times] HO

Intra-BS Soft HO times Performance -


Failures (Requested Stat of
Abis resources Carrier Soft
unavailable)[Times] HO

Intra-BS Soft HO times Performance -


Failures (Radio Stat of
interface abnormal) Carrier Soft
[Times] HO

Intra-BS Soft HO times Performance -


Failures (MS Stat of
rejected)[Times] Carrier Soft
HO

Intra-BS Soft HO times Performance -


Failures (Other Stat of
causes)[Times] Carrier Soft
HO

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 316


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

CS Call Drop Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC Carrier

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

CS Call CS Call Drops times Performance [CS Call Drops (Too many
Drop (Times) Stat of Erasure frames)[Times]]+[CS
Times Carrier CS Call Drops (No reverse frame
TopN Call Drop received)[Times]]+[CS Call
Drops (Abis interface
abnormal)[Times]]+[CS Call
Drops (A2 interface abnormal)
[Times]]+[CS Call Drops
(Other causes)[Times]]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 317


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

CS Call Drop Ratio % Performance (([CS Call Drops (Too many


Stat of Erasure frames)[Times]]+[CS
Carrier CS Call Drops (No reverse frame
Call Drop received)[Times]]+[CS Call
Drops (Abis interface
abnormal)[Times]]+[CS Call
Drops (A2 interface abnormal)
[Times]]+[CS Call Drops
(Other causes)[Times]])/
([Successful CS Call Setups
[Times]]+[Successful CS
Incoming Hard HOs[Times]]))
*{100}

CS Call Drops (Too times Performance -


many Erasure Stat of
frames)[Times] Carrier CS
Call Drop

CS Call Drops (No times Performance -


reverse frame Stat of
received)[Times] Carrier CS
Call Drop

CS Call Drops (Abis times Performance -


interface abnormal) Stat of
[Times] Carrier CS
Call Drop

CS Call Drops (A2 times Performance -


interface abnormal) Stat of
[Times] Carrier CS
Call Drop

CS Call Drops (Other times Performance -


causes)[Times] Stat of
Carrier CS
Call Drop

CS IS-95 Call Drops times Performance -


(HHO fail)[Times] Stat of
Carrier CS
Call Drop

CS IS-2000 Call times Performance -


Drops (HHO fail) Stat of
[Times] Carrier CS
Call Drop

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 318


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

CS Call CS Call Drops times Performance [CS Call Drops (Too many
Drop (Times) Stat of Erasure frames)[Times]]+[CS
Ratio(%) Carrier CS Call Drops (No reverse frame
TopN Call Drop received)[Times]]+[CS Call
Drops (Abis interface
abnormal)[Times]]+[CS Call
Drops (A2 interface abnormal)
[Times]]+[CS Call Drops
(Other causes)[Times]]

CS Call Drop Ratio % Performance (([CS Call Drops (Too many


Stat of Erasure frames)[Times]]+[CS
Carrier CS Call Drops (No reverse frame
Call Drop received)[Times]]+[CS Call
Drops (Abis interface
abnormal)[Times]]+[CS Call
Drops (A2 interface abnormal)
[Times]]+[CS Call Drops
(Other causes)[Times]])/
([Successful CS Call Setups
[Times]]+[Successful CS
Incoming Hard HOs[Times]]))
*{100}

CS Call Drops (Too times Performance -


many Erasure Stat of
frames)[Times] Carrier CS
Call Drop

CS Call Drops (No times Performance -


reverse frame Stat of
received)[Times] Carrier CS
Call Drop

CS Call Drops (Abis times Performance -


interface abnormal) Stat of
[Times] Carrier CS
Call Drop

CS Call Drops (A2 times Performance -


interface abnormal) Stat of
[Times] Carrier CS
Call Drop

CS Call Drops (Other times Performance -


causes)[Times] Stat of
Carrier CS
Call Drop

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 319


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

CS IS-95 Call Drops times Performance -


(HHO fail)[Times] Stat of
Carrier CS
Call Drop

CS IS-2000 Call times Performance -


Drops (HHO fail) Stat of
[Times] Carrier CS
Call Drop

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

CS Call Setup Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC Carrier

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

CS Call CS Attempts[Times] times Performance -


Setup Stat of
Failure Carrier CS
Times Call Setup
TopN

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 320


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

CS Call Setup times Performance [CS A1 Interface Failures


Failures(Times) Stat of [Times]]+[CS Call Resource
Carrier CS Allocation Failures[Times]]+
Call Setup [CS Reverse TCH Preamble
Acquisition Failures[Times]]+
[IS-95 CS Radio Link Setup
Failures[Times]]+[IS-95 CS
Service Connect Failures
[Times]]

CS A1 Interface times Performance -


Failures[Times] Stat of
Carrier CS
Call Setup

CS Call Resource times Performance -


Allocation Failures Stat of
[Times] Carrier CS
Call Setup

CS Reverse TCH times Performance -


Preamble Stat of
Acquisition Failures Carrier CS
[Times] Call Setup

CS Radio Link Setup times Performance -


Failures[Times] Stat of
Carrier CS
Call Setup

CS Service Connect times Performance -


Failures[Times] Stat of
Carrier CS
Call Setup

CS Call Setup % Performance [Successful CS Call Setups


Success Ratio Stat of [Times]]/[CS Attempts
Carrier CS [Times]]*{100}
Call Setup

CS Call CS Attempts[Times] times Performance -


Setup Stat of
Success Carrier CS
Ratio(%) Call Setup
TopN

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 321


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

CS Call Setup times Performance [CS A1 Interface Failures


Failures(Times) Stat of [Times]]+[CS Call Resource
Carrier CS Allocation Failures[Times]]+
Call Setup [CS Reverse TCH Preamble
Acquisition Failures[Times]]+
[IS-95 CS Radio Link Setup
Failures[Times]]+[IS-95 CS
Service Connect Failures
[Times]]

CS A1 Interface times Performance -


Failures[Times] Stat of
Carrier CS
Call Setup

CS Call Resource times Performance -


Allocation Failures Stat of
[Times] Carrier CS
Call Setup

CS Reverse TCH times Performance -


Preamble Stat of
Acquisition Failures Carrier CS
[Times] Call Setup

CS Radio Link Setup times Performance -


Failures[Times] Stat of
Carrier CS
Call Setup

CS Service Connect times Performance -


Failures[Times] Stat of
Carrier CS
Call Setup

CS Call Setup % Performance [Successful CS Call Setups


Success Ratio Stat of [Times]]/[CS Attempts
Carrier CS [Times]]*{100}
Call Setup

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 322


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

PS Call Drop Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC Carrier

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

PS Call PS Call Drops times Performance [PS Call Drops (Too many
Drop (Times) Stat of Erasure frames)[Times]]+[PS
Times Carrier PS Call Drops (No reverse frame
TopN Call Drop received)[Times]]+[PS call
Drops (Abis interface
abnormal)[Times]]+[PS Call
Drops (A1 interface abnormal)
[Times]]+[PS Call Drops (PCF
failure)[Times]]+[PS Call
Drops (Other causes)[Times]]+
[PS Call Drops (HHO failure)
[Times]]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 323


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

CS Call Drop Ratio % Performance (([CS Call Drops (Too many


Stat of Erasure frames)[Times]]+[CS
Carrier CS Call Drops (No reverse frame
Call Drop received)[Times]]+[CS Call
Drops (Abis interface
abnormal)[Times]]+[CS Call
Drops (A2 interface abnormal)
[Times]]+[CS Call Drops
(Other causes)[Times]])/
([Successful CS Call Setups
[Times]]+[Successful CS
Incoming Hard HOs[Times]]))
*{100}

PS Call Drops (Too times Performance -


many Erasure Stat of
frames)[Times] Carrier PS
Call Drop

PS Call Drops (No times Performance -


reverse frame Stat of
received)[Times] Carrier PS
Call Drop

PS call Drops (Abis times Performance -


interface abnormal) Stat of
[Times] Carrier PS
Call Drop

PS Call Drops (A1 times Performance -


interface abnormal) Stat of
[Times] Carrier PS
Call Drop

PS Call Drops (PCF times Performance -


failure)[Times] Stat of
Carrier PS
Call Drop

PS Call Drops (Other times Performance -


causes)[Times] Stat of
Carrier PS
Call Drop

PS Call Drops (HHO times Performance -


failure)[Times] Stat of
Carrier PS
Call Drop

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 324


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

PS Call PS Call Drops times Performance [PS Call Drops (Too many
Drop (Times) Stat of Erasure frames)[Times]]+[PS
Ratio(%) Carrier PS Call Drops (No reverse frame
TopN Call Drop received)[Times]]+[PS call
Drops (Abis interface
abnormal)[Times]]+[PS Call
Drops (A1 interface abnormal)
[Times]]+[PS Call Drops (PCF
failure)[Times]]+[PS Call
Drops (Other causes)[Times]]+
[PS Call Drops (HHO failure)
[Times]]

CS Call Drop Ratio % Performance (([CS Call Drops (Too many


Stat of Erasure frames)[Times]]+[CS
Carrier CS Call Drops (No reverse frame
Call Drop received)[Times]]+[CS Call
Drops (Abis interface
abnormal)[Times]]+[CS Call
Drops (A2 interface abnormal)
[Times]]+[CS Call Drops
(Other causes)[Times]])/
([Successful CS Call Setups
[Times]]+[Successful CS
Incoming Hard HOs[Times]]))
*{100}

PS Call Drops (Too times Performance -


many Erasure Stat of
frames)[Times] Carrier PS
Call Drop

PS Call Drops (No times Performance -


reverse frame Stat of
received)[Times] Carrier PS
Call Drop

PS call Drops (Abis times Performance -


interface abnormal) Stat of
[Times] Carrier PS
Call Drop

PS Call Drops (A1 times Performance -


interface abnormal) Stat of
[Times] Carrier PS
Call Drop

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 325


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

PS Call Drops (PCF times Performance -


failure)[Times] Stat of
Carrier PS
Call Drop

PS Call Drops (Other times Performance -


causes)[Times] Stat of
Carrier PS
Call Drop

PS Call Drops (HHO times Performance -


failure)[Times] Stat of
Carrier PS
Call Drop

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

PS Call Setup Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC Carrier

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 326


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

PS Call PS Attempts[Times] times Performance -


Setup Stat of
Failure Carrier PS
Times Call Setup
TopN
PS Call Setup times Performance [PS A1 Interface Failures
Failures(Times) Stat of [Times]]+[PS Call Resource
Carrier PS Allocation Failures[Times]]+
Call Setup [PS Reverse TCH Preamble
Acquisition Failures[Times]]+
[PS Radio Link Setup Failures
[Times]]+[PS TCH Signaling
Exchange Failures[Times]]

PS Call Setup % Performance [Successful PS Call Setups


Success Ratio Stat of [Times]]/[PS Attempts
Carrier PS [Times]]*{100}
Call Setup

PS A1 Interface times Performance -


Failures[Times] Stat of
Carrier PS
Call Setup

PS Call Resource times Performance -


Allocation Failures Stat of
[Times] Carrier PS
Call Setup

PS Reverse TCH times Performance -


Preamble Stat of
Acquisition Failures Carrier PS
[Times] Call Setup

PS Radio Link Setup times Performance -


Failures[Times] Stat of
Carrier PS
Call Setup

PS TCH Signaling times Performance -


Exchange Failures Stat of
[Times] Carrier PS
Call Setup

PS Call PS Attempts[Times] times Performance -


Setup Stat of
Success Carrier PS
Call Setup

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 327


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Ratio(%) PS Call Setup times Performance [PS A1 Interface Failures


TopN Failures(Times) Stat of [Times]]+[PS Call Resource
Carrier PS Allocation Failures[Times]]+
Call Setup [PS Reverse TCH Preamble
Acquisition Failures[Times]]+
[PS Radio Link Setup Failures
[Times]]+[PS TCH Signaling
Exchange Failures[Times]]

PS Call Setup % Performance [Successful PS Call Setups


Success Ratio Stat of [Times]]/[PS Attempts
Carrier PS [Times]]*{100}
Call Setup

PS A1 Interface times Performance -


Failures[Times] Stat of
Carrier PS
Call Setup

PS Call Resource times Performance -


Allocation Failures Stat of
[Times] Carrier PS
Call Setup

PS Reverse TCH times Performance -


Preamble Stat of
Acquisition Failures Carrier PS
[Times] Call Setup

PS Radio Link Setup times Performance -


Failures[Times] Stat of
Carrier PS
Call Setup

PS TCH Signaling times Performance -


Exchange Failures Stat of
[Times] Carrier PS
Call Setup

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 328


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

RSSI Performace Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSCVG3Pilot

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

RSSI Main RSSI Average none RSSI -


Performa Value[0.1dBm] Performance
nce Stat
Report
Div RSSI Average none RSSI -
Value[0.1dBm] Performance
Stat

Difference Between none RSSI [Main RSSI Average Value


Main And Diversity Performance [0.1dBm]]-[Div RSSI Average
RSSI Average Value Stat Value[0.1dBm]]

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 329


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Traffic Traffic Performance Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC Carrier

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Highest Total Traffic Erl Carrier [Density of Traffic Carried on


Traffic Traffic TCH (Excluding HO) (CS-
Performance FCH)[Erl]]+[Density of
Stat(FCH) Traffic Carried on TCH
(Excluding HO) (PS-FCH)
[Erl]]+[CE Traffic Density-PS
SCH[Erl]]

Density of Traffic Erl Carrier -


Carried on TCH Traffic
(Excluding HO) (CS- Performance
FCH)[Erl] Stat(FCH)

Density of Traffic Erl Carrier -


Carried on TCH Traffic
(Excluding HO) (PS- Performance
FCH)[Erl] Stat(FCH)

CE Traffic Density- Erl Carrier -


PS SCH[Erl] Traffic
Performance
Stat(Forward
SCH)

CE Traffic Density - Erl Carrier -


Speech Service FCH Traffic
[Erl] Performance
Stat(FCH)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 330


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

CE Traffic Density - Erl Carrier -


Packet Service FCH Traffic
[Erl] Performance
Stat(FCH)

WALSH Traffic Erl Carrier -


Density-FCH[Erl] Traffic
Performance
Stat(FCH)

Lowest Total Traffic Erl Carrier [Density of Traffic Carried on


Traffic Traffic TCH (Excluding HO) (CS-
Performance FCH)[Erl]]+[Density of
Stat(FCH) Traffic Carried on TCH
(Excluding HO) (PS-FCH)
[Erl]]+[CE Traffic Density-PS
SCH[Erl]]

Density of Traffic Erl Carrier -


Carried on TCH Traffic
(Excluding HO) (CS- Performance
FCH)[Erl] Stat(FCH)

Density of Traffic Erl Carrier -


Carried on TCH Traffic
(Excluding HO) (PS- Performance
FCH)[Erl] Stat(FCH)

CE Traffic Density- Erl Carrier -


PS SCH[Erl] Traffic
Performance
Stat(Forward
SCH)

CE Traffic Density - Erl Carrier -


Speech Service FCH Traffic
[Erl] Performance
Stat(FCH)

CE Traffic Density - Erl Carrier -


Packet Service FCH Traffic
[Erl] Performance
Stat(FCH)

WALSH Traffic Erl Carrier -


Density-FCH[Erl] Traffic
Performance
Stat(FCH)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 331


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

TCH Congestion Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC Carrier

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

TCH TCH Congestion times Performance [TCH Assignment Failures


Congesti Times Stat of (WALSH shortage)[Times]]+
on Times Carrier TCH [TCH Assignment Failures
TopN Congestion (Low forward power)[Times]]
+[TCH Assignment Failures
(Low reverse power)[Times]]+
[TCH Assignment Failures
(Channel shortage)[Times]]+
[TCH Assignment Failures
(Other causes)[Times]]

TCH Congestion % Performance (([TCH Assignment Requests


Ratio Stat of [Times]]-[Successful TCH
Carrier TCH Assignments[Times]])/[TCH
Congestion Assignment Requests[Times]])
*{100}

TCH Assignment times Performance -


Failures (WALSH Stat of
shortage)[Times] Carrier TCH
Congestion

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 332


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

TCH Assignment times Performance -


Failures (Low Stat of
forward power) Carrier TCH
[Times] Congestion

TCH Assignment times Performance -


Failures (Low Stat of
reverse power) Carrier TCH
[Times] Congestion

TCH Assignment times Performance -


Failures (Channel Stat of
shortage)[Times] Carrier TCH
Congestion

TCH Assignment times Performance -


Failures (Other Stat of
causes)[Times] Carrier TCH
Congestion

TCH TCH Congestion times Performance [TCH Assignment Failures


Congesti Times Stat of (WALSH shortage)[Times]]+
on Ratio Carrier TCH [TCH Assignment Failures
(%) Congestion (Low forward power)[Times]]
TopN +[TCH Assignment Failures
(Low reverse power)[Times]]+
[TCH Assignment Failures
(Channel shortage)[Times]]+
[TCH Assignment Failures
(Other causes)[Times]]

TCH Congestion % Performance (([TCH Assignment Requests


Ratio Stat of [Times]]-[Successful TCH
Carrier TCH Assignments[Times]])/[TCH
Congestion Assignment Requests[Times]])
*{100}

TCH Assignment times Performance -


Failures (WALSH Stat of
shortage)[Times] Carrier TCH
Congestion

TCH Assignment times Performance -


Failures (Low Stat of
forward power) Carrier TCH
[Times] Congestion

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 333


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

TCH Assignment times Performance -


Failures (Low Stat of
reverse power) Carrier TCH
[Times] Congestion

TCH Assignment times Performance -


Failures (Channel Stat of
shortage)[Times] Carrier TCH
Congestion

TCH Assignment times Performance -


Failures (Other Stat of
causes)[Times] Carrier TCH
Congestion

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Transmit Power of Carrier Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC Carrier

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 334


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Average Average Transmit dBm Performance -


Transmit Power of Carrier Stat of Link
Power of [dBm] Information
Carrier Measuremen
TOPN t
Report
Max Transmit Power dBm Performance -
of Carrier[dBm] Stat of Link
Information
Measuremen
t

Min Transmit Power dBm Performance -


of Carrier[dBm] Stat of Link
Information
Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

8.2 CDMA BSS EV-DORB Performance Report

8.2.1 HRPD Session Report

BSC HRPD Session KPI Report

Report Type
Simple Report

NE Type
CBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 335


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

HRPD HRPD Session Setup % Performance -


Session Success Ratio[%] Stat of BSC
KPI HRPD
Sessions

Access % Performance -
Authentication Stat of BSC
Success Ratio[%] HRPD
Sessions

HRPD Session Setup ms Performance -


Average Time Stat of BSC
[Millisecond] HRPD
Sessions

Maximum HRPD numb Performance -


Sessions[Entries] er Stat of BSC
HRPD
Sessions

Maximum number of numb Performance -


active HRPD er Stat of BSC
Sessions[Entries] HRPD
Sessions

Average Duration of ms Performance -


HRPD Session Setup Stat of BSC
(DO B) HRPD
[Millisecond] Sessions

Maximum Number entrie Performance -


of Active HRPD s Stat of BSC
Sessions (DO B) HRPD
[Entries] Sessions

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 336


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

HRPD Session Setup Scale Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Session Maximum HRPD numb Performance -


Number Sessions[Entries] er Stat of BSC
and HRPD
Active Sessions
Ratio
Minimum HRPD numb Performance -
Sessions[Entries] er Stat of BSC
HRPD
Sessions

Maximum number of numb Performance -


active HRPD er Stat of BSC
Sessions[Entries] HRPD
Sessions

Minimum number of numb Performance -


active HRPD er Stat of BSC
Sessions[Entries] HRPD
Sessions

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 337


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Maximum Number entrie Performance -


of Active HRPD s Stat of BSC
Sessions (DO B) HRPD
[Entries] Sessions

Subscribe Active none Performance ([Maximum number of active


Ratio[%] Stat of BSC HRPD Sessions[Entries]]+
HRPD [Minimum number of active
Sessions HRPD Sessions[Entries]])/
{2}/(([Maximum HRPD
Sessions[Entries]]+[Minimum
HRPD Sessions[Entries]])/
{2})*{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

HRPD Session Setup Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 338


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

BSC HRPD Session setup times Performance -


Session Requests[Times] Stat of BSC
Setup HRPD
Success Sessions
Ratio
HRPD Session Setup % Performance -
Success Ratio[%] Stat of BSC
HRPD
Sessions

HRPD Session Setup ms Performance -


Average Time Stat of BSC
[Millisecond] HRPD
Sessions

Average Duration of ms Performance -


HRPD Session Setup Stat of BSC
(DO B) HRPD
[Millisecond] Sessions

HRPD HRPD Session none Performance [HRPD Session attemp


Session attemp Failures(No Stat of BSC Failures(No HardwareID
Setup HardwareID Request HRPD Request Sent)[Times]]/[HRPD
Failure Sent) Ratio Sessions Session attempt Failure
[Times]]*{100}

HRPD Session none Performance [HRPD Session attemp


attemp Failures(No Stat of BSC Failures(No HardwareID
HardwareID HRPD Response Received)[Times]]/
Response Received) Sessions [HRPD Session attempt Failure
Ratio [Times]]*{100}

HRPD Session none Performance [HRPD Session attemp


attemp Failures(No Stat of BSC Failures(No UATIAssignment
UATIAssignment HRPD Sent)[Times]]/[HRPD Session
Sent) Ratio Sessions attempt Failure[Times]]*
{100}

HRPD Session none Performance [HRPD Session attemp


attemp Failures(No Stat of BSC Failures(No UATIComplete
UATIComplete HRPD Received)[Times]]/[HRPD
Received) Ratio Sessions Session attempt Failure
[Times]]*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 339


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Carrier HRPD Session Setup Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC Carrier

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

HRPD HRPD Session Setup % Performance -


Setup Success Ratio[%] Stat of
SuccR Carrier
BottomN HRPD
Sessions

HRPD Session setup times Performance -


Requests[Times] Stat of
Carrier
HRPD
Sessions

HRPD Session times Performance -


attemp Failures(No Stat of
HardwareID Request Carrier
Sent)[Times] HRPD
Sessions

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 340


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

HRPD Session times Performance -


attemp Failures(No Stat of
HardwareID Carrier
Response Received) HRPD
[Times] Sessions

HRPD Session times Performance -


attemp Failures(No Stat of
UATIAssignment Carrier
Sent)[Times] HRPD
Sessions

HRPD Session times Performance -


attemp Failures(No Stat of
UATIComplete Carrier
Received)[Times] HRPD
Sessions

Session HRPD Session none Performance [HRPD Session attemp


Setup attemp Failures Stat of Failures(No HardwareID
Fail [Times] Carrier Request Sent)[Times]]+
Times HRPD [HRPD Session attemp
TOPN Sessions Failures(No HardwareID
Response Received)[Times]]+
[HRPD Session attemp
Failures(No UATIAssignment
Sent)[Times]]+[HRPD
Session attemp Failures(No
UATIComplete Received)
[Times]]

HRPD Session Setup % Performance -


Success Ratio[%] Stat of
Carrier
HRPD
Sessions

HRPD Session times Performance -


attemp Failures(No Stat of
HardwareID Request Carrier
Sent)[Times] HRPD
Sessions

HRPD Session times Performance -


attemp Failures(No Stat of
HardwareID Carrier
Response Received) HRPD
[Times] Sessions

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 341


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

HRPD Session times Performance -


attemp Failures(No Stat of
UATIAssignment Carrier
Sent)[Times] HRPD
Sessions

HRPD Session times Performance -


attemp Failures(No Stat of
UATIComplete Carrier
Received)[Times] HRPD
Sessions

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

HRPD Session Release Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 342


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Session Mean HRPD Session none Performance ([HRPD Session Released


Released Released[Times/ Stat of BSC from AT(Normal closed)
from AT hour] HRPD [Times]]+[HRPD Session
and AN Sessions Released from AT(Protocol
error)[Times]]+[HRPD
Session Released from AT
(Protocol configuration failure)
[Times]]+[HRPD Session
Released from AT(Protocol
negotiation error)[Times]]+
[HRPD Session Released from
AT(Session configuration
failure)[Times]]+[HRPD
Session Released from AT
(Others)[Times]]+[HRPD
Session Released from AN
(Configure failed)[Times]]+
[HRPD Session Released from
AN(Keep alive timer expired)
[Times]]+[HRPD Session
Released from AN(MML
operated)[Times]]+[HRPD
Session Released from AN
(Authority failed)[Times]]+
[HRPD Session Released from
AN(Source AN release in inter
AN handoff)[Times]]+[HRPD
Session Released from AN
(Release old session in session
setup)[Times]]+[HRPD
Session Released from AN
(Others)[Times]])/{GP}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 343


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Mean HRPD Session none Performance ([HRPD Session Released


from AT[Times/ Stat of BSC from AT(Normal closed)
hour] HRPD [Times]]+[HRPD Session
Sessions Released from AT(Protocol
error)[Times]]+[HRPD
Session Released from AT
(Protocol configuration failure)
[Times]]+[HRPD Session
Released from AT(Protocol
negotiation error)[Times]]+
[HRPD Session Released from
AT(Session configuration
failure)[Times]]+[HRPD
Session Released from AT
(Others)[Times]])/{GP}

Mean HRPD Session none Performance ([HRPD Session Released


Released from AN Stat of BSC from AN(Configure failed)
[Times/hour] HRPD [Times]]+[HRPD Session
Sessions Released from AN(Keep alive
timer expired)[Times]]+
[HRPD Session Released from
AN(MML operated)[Times]]+
[HRPD Session Released from
AN(Authority failed)[Times]]
+[HRPD Session Released
from AN(Source AN release in
inter AN handoff)[Times]]+
[HRPD Session Released from
AN(Release old session in
session setup)[Times]]+
[HRPD Session Released from
AN(Others)[Times]])/{GP}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 344


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Causes of HRPD Session none Performance [HRPD Session Released from


HRPD Released from AT Stat of BSC AT(Normal closed)[Times]]+
Session HRPD [HRPD Session Released from
Release Sessions AT(Protocol error)[Times]]+
[HRPD Session Released from
AT(Protocol configuration
failure)[Times]]+[HRPD
Session Released from AT
(Protocol negotiation error)
[Times]]+[HRPD Session
Released from AT(Session
configuration failure)[Times]]
+[HRPD Session Released
from AT(Others)[Times]]

HRPD Session none Performance [HRPD Session Released from


Released from AN Stat of BSC AN(Configure failed)[Times]]
HRPD +[HRPD Session Released
Sessions from AN(Keep alive timer
expired)[Times]]+[HRPD
Session Released from AN
(MML operated)[Times]]+
[HRPD Session Released from
AN(Authority failed)[Times]]
+[HRPD Session Released
from AN(Source AN release in
inter AN handoff)[Times]]+
[HRPD Session Released from
AN(Release old session in
session setup)[Times]]+
[HRPD Session Released from
AN(Others)[Times]]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 345


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

HRPD Session none Performance [HRPD Session Released from


Released from AT Stat of BSC AT(Normal closed)[Times]]/
(Normal closed) [%] HRPD ([HRPD Session Released
Sessions from AT(Normal closed)
[Times]]+[HRPD Session
Released from AT(Protocol
error)[Times]]+[HRPD
Session Released from AT
(Protocol configuration failure)
[Times]]+[HRPD Session
Released from AT(Protocol
negotiation error)[Times]]+
[HRPD Session Released from
AT(Session configuration
failure)[Times]]+[HRPD
Session Released from AT
(Others)[Times]]+[HRPD
Session Released from AN
(Configure failed)[Times]]+
[HRPD Session Released from
AN(Keep alive timer expired)
[Times]]+[HRPD Session
Released from AN(MML
operated)[Times]]+[HRPD
Session Released from AN
(Authority failed)[Times]]+
[HRPD Session Released from
AN(Source AN release in inter
AN handoff)[Times]]+[HRPD
Session Released from AN
(Release old session in session
setup)[Times]]+[HRPD
Session Released from AN
(Others)[Times]])*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 346


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

HRPD Session none Performance [HRPD Session Released from


Released from AT Stat of BSC AT(Protocol error)[Times]]/
(Protocol error) [%] HRPD ([HRPD Session Released
Sessions from AT(Normal closed)
[Times]]+[HRPD Session
Released from AT(Protocol
error)[Times]]+[HRPD
Session Released from AT
(Protocol configuration failure)
[Times]]+[HRPD Session
Released from AT(Protocol
negotiation error)[Times]]+
[HRPD Session Released from
AT(Session configuration
failure)[Times]]+[HRPD
Session Released from AT
(Others)[Times]]+[HRPD
Session Released from AN
(Configure failed)[Times]]+
[HRPD Session Released from
AN(Keep alive timer expired)
[Times]]+[HRPD Session
Released from AN(MML
operated)[Times]]+[HRPD
Session Released from AN
(Authority failed)[Times]]+
[HRPD Session Released from
AN(Source AN release in inter
AN handoff)[Times]]+[HRPD
Session Released from AN
(Release old session in session
setup)[Times]]+[HRPD
Session Released from AN
(Others)[Times]])*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 347


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

HRPD Session none Performance [HRPD Session Released from


Released from AT Stat of BSC AT(Protocol configuration
(Protocol HRPD failure)[Times]]/([HRPD
configuration failure) Sessions Session Released from AT
[%] (Normal closed)[Times]]+
[HRPD Session Released from
AT(Protocol error)[Times]]+
[HRPD Session Released from
AT(Protocol configuration
failure)[Times]]+[HRPD
Session Released from AT
(Protocol negotiation error)
[Times]]+[HRPD Session
Released from AT(Session
configuration failure)[Times]]
+[HRPD Session Released
from AT(Others)[Times]]+
[HRPD Session Released from
AN(Configure failed)[Times]]
+[HRPD Session Released
from AN(Keep alive timer
expired)[Times]]+[HRPD
Session Released from AN
(MML operated)[Times]]+
[HRPD Session Released from
AN(Authority failed)[Times]]
+[HRPD Session Released
from AN(Source AN release in
inter AN handoff)[Times]]+
[HRPD Session Released from
AN(Release old session in
session setup)[Times]]+
[HRPD Session Released from
AN(Others)[Times]])*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 348


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

HRPD Session none Performance [HRPD Session Released from


Released from AT Stat of BSC AT(Protocol negotiation error)
(Protocol negotiation HRPD [Times]]/([HRPD Session
error) [%] Sessions Released from AT(Normal
closed)[Times]]+[HRPD
Session Released from AT
(Protocol error)[Times]]+
[HRPD Session Released from
AT(Protocol configuration
failure)[Times]]+[HRPD
Session Released from AT
(Protocol negotiation error)
[Times]]+[HRPD Session
Released from AT(Session
configuration failure)[Times]]
+[HRPD Session Released
from AT(Others)[Times]]+
[HRPD Session Released from
AN(Configure failed)[Times]]
+[HRPD Session Released
from AN(Keep alive timer
expired)[Times]]+[HRPD
Session Released from AN
(MML operated)[Times]]+
[HRPD Session Released from
AN(Authority failed)[Times]]
+[HRPD Session Released
from AN(Source AN release in
inter AN handoff)[Times]]+
[HRPD Session Released from
AN(Release old session in
session setup)[Times]]+
[HRPD Session Released from
AN(Others)[Times]])*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 349


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

HRPD Session none Performance [HRPD Session Released from


Released from AT Stat of BSC AT(Session configuration
(Session HRPD failure)[Times]]/([HRPD
configuration failure) Sessions Session Released from AT
[%] (Normal closed)[Times]]+
[HRPD Session Released from
AT(Protocol error)[Times]]+
[HRPD Session Released from
AT(Protocol configuration
failure)[Times]]+[HRPD
Session Released from AT
(Protocol negotiation error)
[Times]]+[HRPD Session
Released from AT(Session
configuration failure)[Times]]
+[HRPD Session Released
from AT(Others)[Times]]+
[HRPD Session Released from
AN(Configure failed)[Times]]
+[HRPD Session Released
from AN(Keep alive timer
expired)[Times]]+[HRPD
Session Released from AN
(MML operated)[Times]]+
[HRPD Session Released from
AN(Authority failed)[Times]]
+[HRPD Session Released
from AN(Source AN release in
inter AN handoff)[Times]]+
[HRPD Session Released from
AN(Release old session in
session setup)[Times]]+
[HRPD Session Released from
AN(Others)[Times]])*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 350


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

HRPD Session none Performance [HRPD Session Released from


Released from AT Stat of BSC AT(Others)[Times]]/([HRPD
(Others) Ratio[%] HRPD Session Released from AT
Sessions (Normal closed)[Times]]+
[HRPD Session Released from
AT(Protocol error)[Times]]+
[HRPD Session Released from
AT(Protocol configuration
failure)[Times]]+[HRPD
Session Released from AT
(Protocol negotiation error)
[Times]]+[HRPD Session
Released from AT(Session
configuration failure)[Times]]
+[HRPD Session Released
from AT(Others)[Times]]+
[HRPD Session Released from
AN(Configure failed)[Times]]
+[HRPD Session Released
from AN(Keep alive timer
expired)[Times]]+[HRPD
Session Released from AN
(MML operated)[Times]]+
[HRPD Session Released from
AN(Authority failed)[Times]]
+[HRPD Session Released
from AN(Source AN release in
inter AN handoff)[Times]]+
[HRPD Session Released from
AN(Release old session in
session setup)[Times]]+
[HRPD Session Released from
AN(Others)[Times]])*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 351


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

HRPD Session none Performance [HRPD Session Released from


Released from AN Stat of BSC AN(Configure failed)[Times]]/
(Configure failed) HRPD ([HRPD Session Released
[%] Sessions from AT(Normal closed)
[Times]]+[HRPD Session
Released from AT(Protocol
error)[Times]]+[HRPD
Session Released from AT
(Protocol configuration failure)
[Times]]+[HRPD Session
Released from AT(Protocol
negotiation error)[Times]]+
[HRPD Session Released from
AT(Session configuration
failure)[Times]]+[HRPD
Session Released from AT
(Others)[Times]]+[HRPD
Session Released from AN
(Configure failed)[Times]]+
[HRPD Session Released from
AN(Keep alive timer expired)
[Times]]+[HRPD Session
Released from AN(MML
operated)[Times]]+[HRPD
Session Released from AN
(Authority failed)[Times]]+
[HRPD Session Released from
AN(Source AN release in inter
AN handoff)[Times]]+[HRPD
Session Released from AN
(Release old session in session
setup)[Times]]+[HRPD
Session Released from AN
(Others)[Times]])*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 352


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

HRPD Session none Performance [HRPD Session Released from


Released from AN Stat of BSC AN(Keep alive timer expired)
(Keep alive timer HRPD [Times]]/([HRPD Session
expired) [%] Sessions Released from AT(Normal
closed)[Times]]+[HRPD
Session Released from AT
(Protocol error)[Times]]+
[HRPD Session Released from
AT(Protocol configuration
failure)[Times]]+[HRPD
Session Released from AT
(Protocol negotiation error)
[Times]]+[HRPD Session
Released from AT(Session
configuration failure)[Times]]
+[HRPD Session Released
from AT(Others)[Times]]+
[HRPD Session Released from
AN(Configure failed)[Times]]
+[HRPD Session Released
from AN(Keep alive timer
expired)[Times]]+[HRPD
Session Released from AN
(MML operated)[Times]]+
[HRPD Session Released from
AN(Authority failed)[Times]]
+[HRPD Session Released
from AN(Source AN release in
inter AN handoff)[Times]]+
[HRPD Session Released from
AN(Release old session in
session setup)[Times]]+
[HRPD Session Released from
AN(Others)[Times]])*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 353


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

HRPD Session none Performance [HRPD Session Released from


Released from AN Stat of BSC AN(MML operated)[Times]]/
(MML operated) [%] HRPD ([HRPD Session Released
Sessions from AT(Normal closed)
[Times]]+[HRPD Session
Released from AT(Protocol
error)[Times]]+[HRPD
Session Released from AT
(Protocol configuration failure)
[Times]]+[HRPD Session
Released from AT(Protocol
negotiation error)[Times]]+
[HRPD Session Released from
AT(Session configuration
failure)[Times]]+[HRPD
Session Released from AT
(Others)[Times]]+[HRPD
Session Released from AN
(Configure failed)[Times]]+
[HRPD Session Released from
AN(Keep alive timer expired)
[Times]]+[HRPD Session
Released from AN(MML
operated)[Times]]+[HRPD
Session Released from AN
(Authority failed)[Times]]+
[HRPD Session Released from
AN(Source AN release in inter
AN handoff)[Times]]+[HRPD
Session Released from AN
(Release old session in session
setup)[Times]]+[HRPD
Session Released from AN
(Others)[Times]])*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 354


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

HRPD Session none Performance [HRPD Session Released from


Released from AN Stat of BSC AN(Authority failed)[Times]]/
(Authority failed) HRPD ([HRPD Session Released
[%] Sessions from AT(Normal closed)
[Times]]+[HRPD Session
Released from AT(Protocol
error)[Times]]+[HRPD
Session Released from AT
(Protocol configuration failure)
[Times]]+[HRPD Session
Released from AT(Protocol
negotiation error)[Times]]+
[HRPD Session Released from
AT(Session configuration
failure)[Times]]+[HRPD
Session Released from AT
(Others)[Times]]+[HRPD
Session Released from AN
(Configure failed)[Times]]+
[HRPD Session Released from
AN(Keep alive timer expired)
[Times]]+[HRPD Session
Released from AN(MML
operated)[Times]]+[HRPD
Session Released from AN
(Authority failed)[Times]]+
[HRPD Session Released from
AN(Source AN release in inter
AN handoff)[Times]]+[HRPD
Session Released from AN
(Release old session in session
setup)[Times]]+[HRPD
Session Released from AN
(Others)[Times]])*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 355


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

HRPD Session none Performance [HRPD Session Released from


Released from AN Stat of BSC AN(Source AN release in inter
(Source AN release HRPD AN handoff)[Times]]/([HRPD
in inter AN handoff) Sessions Session Released from AT
[%] (Normal closed)[Times]]+
[HRPD Session Released from
AT(Protocol error)[Times]]+
[HRPD Session Released from
AT(Protocol configuration
failure)[Times]]+[HRPD
Session Released from AT
(Protocol negotiation error)
[Times]]+[HRPD Session
Released from AT(Session
configuration failure)[Times]]
+[HRPD Session Released
from AT(Others)[Times]]+
[HRPD Session Released from
AN(Configure failed)[Times]]
+[HRPD Session Released
from AN(Keep alive timer
expired)[Times]]+[HRPD
Session Released from AN
(MML operated)[Times]]+
[HRPD Session Released from
AN(Authority failed)[Times]]
+[HRPD Session Released
from AN(Source AN release in
inter AN handoff)[Times]]+
[HRPD Session Released from
AN(Release old session in
session setup)[Times]]+
[HRPD Session Released from
AN(Others)[Times]])*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 356


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

HRPD Session none Performance [HRPD Session Released from


Released from AN Stat of BSC AN(Release old session in
(Release old session HRPD session setup)[Times]]/
in session setup) [%] Sessions ([HRPD Session Released
from AT(Normal closed)
[Times]]+[HRPD Session
Released from AT(Protocol
error)[Times]]+[HRPD
Session Released from AT
(Protocol configuration failure)
[Times]]+[HRPD Session
Released from AT(Protocol
negotiation error)[Times]]+
[HRPD Session Released from
AT(Session configuration
failure)[Times]]+[HRPD
Session Released from AT
(Others)[Times]]+[HRPD
Session Released from AN
(Configure failed)[Times]]+
[HRPD Session Released from
AN(Keep alive timer expired)
[Times]]+[HRPD Session
Released from AN(MML
operated)[Times]]+[HRPD
Session Released from AN
(Authority failed)[Times]]+
[HRPD Session Released from
AN(Source AN release in inter
AN handoff)[Times]]+[HRPD
Session Released from AN
(Release old session in session
setup)[Times]]+[HRPD
Session Released from AN
(Others)[Times]])*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 357


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

HRPD Session none Performance [HRPD Session Released from


Released from AN Stat of BSC AN(Others)[Times]]/([HRPD
(Others) [%] HRPD Session Released from AT
Sessions (Normal closed)[Times]]+
[HRPD Session Released from
AT(Protocol error)[Times]]+
[HRPD Session Released from
AT(Protocol configuration
failure)[Times]]+[HRPD
Session Released from AT
(Protocol negotiation error)
[Times]]+[HRPD Session
Released from AT(Session
configuration failure)[Times]]
+[HRPD Session Released
from AT(Others)[Times]]+
[HRPD Session Released from
AN(Configure failed)[Times]]
+[HRPD Session Released
from AN(Keep alive timer
expired)[Times]]+[HRPD
Session Released from AN
(MML operated)[Times]]+
[HRPD Session Released from
AN(Authority failed)[Times]]
+[HRPD Session Released
from AN(Source AN release in
inter AN handoff)[Times]]+
[HRPD Session Released from
AN(Release old session in
session setup)[Times]]+
[HRPD Session Released from
AN(Others)[Times]])*{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 358


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

HRPD Access Authentication Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Access Access % Performance -


Auth Authentication Stat of BSC
Successf Success Ratio[%] HRPD
ul Ratio Sessions

Access times Performance -


Authentication Stat of BSC
Attempts[Times] HRPD
Sessions

Causes of Access none Performance [Access Authentication


the Authentication Stat of BSC Rejections[Times]]/([Access
Access Rejections [%] HRPD Authentication Attempts
Auth Fail Sessions [Times]]-[Successful Access
Authentications[Times]])*
{100}

Access none Performance [Access Authentication LCP


Authentication LCP Stat of BSC Negotiation Failure[Times]]/
Failure [%] HRPD ([Access Authentication
Sessions Attempts[Times]]-[Successful
Access Authentications
[Times]])*{100}

Access none Performance [Access Authentication No


Authentication Stat of BSC Resource[Times]]/([Access
Apply Resource HRPD Authentication Attempts
Failure [%] Sessions [Times]]-[Successful Access
Authentications[Times]])*
{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 359


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Access none Performance ([Access Authentication


Authentication Stat of BSC Attempts[Times]]-[Successful
Rejections(Other HRPD Access Authentications
causes)[%] Sessions [Times]]-[Access
Authentication Rejections
[Times]]-[Access
Authentication LCP
Negotiation Failure[Times]]-
[Access Authentication No
Resource[Times]])/([Access
Authentication Attempts
[Times]]-[Successful Access
Authentications[Times]])*
{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Carrier HRPD Session KPI Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC Carrier

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 360


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

HRPD HRPD Session Setup % Performance -


Session Success Ratio[%] Stat of
KPI Carrier
HRPD
Sessions

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

8.2.2 Cover Report

Overview of BSC KPI Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

HRPD HRPD Session Setup % Performance -


Session Success Ratio[%] Stat of
Performa Carrier
nce HRPD
Sessions

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 361


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Access % Performance -
Authentication Stat of BSC
Success Ratio[%] HRPD
Sessions

Accessab EV-DO Paging % Performance -


lity Success Ratio[%] Stat of BSC
HRPD
Sessions

Connection Success % Performance -


Ratio[%] Stat of BSC
EV-DO
Connection
Setup

Connection Success % Performance -


Ratio(DO B)[%] Stat of BSC
EV-DO
Connection
Setup

Call Connection Drop % Performance -


Retainabi Ratio[%] Stat of BSC
lity EV-DO
Connection
Release

Connection Drop % Performance -


Ratio(DO B)[%] Stat of BSC
EV-DO
Connection
Release

Traffic Drop Ratio none EV-DO BSC ([DO 0 Traffic Channel


[Minute] Traffic Connection Total time(DO 0)
Performance [Second]]+[DO A Traffic
Stat Channel Connection Total time
(DO A) [Second]])/
(([Connection Released (RF
lost)[Times]]+[Connection
Release (HHO Fail)[Times]]+
[Connection Released (Other
causes)[Times]])*{60})

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 362


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Traffic Drop Ratio none EV-DOB ([DO B Traffic Channel


(DO B)[minute] BSC Traffic Connection Duration - 1
Performance Carrier (DO B) [Second]]+[DO
Stat B Traffic Channel Connection
Duration - 2 Carriers (DO B)
[Second]]+[DO B Traffic
Channel Connection Duration -
3 Carriers (DO B) [Second]])/
(([Connection Released (RF
lost)(DO B)[Times]]+
[Connection Release (HHO
Fail)(DO B)[Times]]+
[Connection Released (Other
causes)(DO B)[Times]]-
[Connection Released
(Interoperation Between 1X
and DO)(DO B)[Times]])*
{60})

Mobility Intra-BS Soft HO % Performance -


Success Ratio[%] Stat of BSC
EV-DO
Reverse
Channel Soft
HO

CS of Call Release times CS Call Drop -


Num Performance
Stat

PS of Call Release times PS Call Drop -


Num Performance
Stat

Location Update none Performance ([Location Update Assignment


Assignment Success Stat of BSC (Location Assignment Sent)
Ratio[%] HRPD [Times]]-[Location Update
Sessions Uncompletion(No Location
Complete Received)[Times]])
*{100}/[Location Update
Attempts(Location
Notification Received)
[Times]]*{100}

Intra-AN Hard HO % Performance -


Success Ratio(DO B) Stat of Intra-
[%] AN Hard HO

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 363


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Successful Inter-AN none Performance [Successful Inter-AN


Incoming Hard HOs Stat of Inter- Incoming Hard HOs(DO B)
Ratio(DO B) AN Hard HO [Times]]/[Inter-AN Incoming
Hard HO Requests(DO B)
[Times]]*{100}

Successful Inter-AN none Performance [Successful Inter-AN Hard


Hard HOs Ratio Stat of Inter- HOs(DO B)[Times]]/[Inter-
(DOB) AN Hard HO AN Hard HO Requests(DO B)
[Times]]*{100}

Service Average Forward none DO TCH [DO FTCH Forward RLP


Integrity Speed During of Forward RLP Layer Transmit Throughput
Connetion Hoding Throughput [byte]]*{8}/({GP}*{60}*[DO
Stat Average Active User Count
[entries]]*{1000})

Get Forward Speed none RLP [SAR Octets Sent on Forward


During of Connetion Throughput Channels(Excluding those
Hoding(DO B) Stat Resent) (DO B) [KB]]*{8}/
(([DO B Traffic Channel
Connection Duration - 1
Carrier (DO B) [Second]]+[DO
B Traffic Channel Connection
Duration - 2 Carriers (DO B)
[Second]]+[DO B Traffic
Channel Connection Duration -
3 Carriers (DO B) [Second]])*
{1000})

Forward Link Data % RLP -


Retransmission Rate Throughput
[%] Stat

Reverse Link Data % RLP -


Retransmission Rate Throughput
[%] Stat

SAR Forward Link % RLP -


Data Retransmission Throughput
Rate (DOB) [%] Stat

RLP Reverse Link % RLP -


Data Retransmission Throughput
Rate (DOB) [%] Stat

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 364


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Network Forward RLP none Performance [Total RLP Octets Sent on


Capabilit Throughput[Kbps] Stat of EV- Forward Channels[KB]]*{8}*
y DO Service {1024}/({1000}*{GP})
Data
Throughput

Reverse RLP none RLP [RLP Octets Received on


Throughput[kbps] Throughput Reverse Channels[KB]]*{8}*
Stat {1024}/({1000}*{GP})

Forward SAP none RLP ([SAR Octets Sent on Forward


Throughput (DO B) Throughput Channels(Excluding those
[Kbps] Stat Resent) (DO B) [KB]]*{8}+
[SAR Octets Resent on
Forward Channels (DO B)
[Byte]]*{8}/{1000})/{GP}

Reverse RLP none Do Carrier [RLP Octets Received on


Throughput (DO B) Performance Reverse Channels (DO B)
[Kbps] Mesurement [KB]]*{8}/({GP}*{1000})

Traffic Density on none EV-DO BSC ([DO 0 Traffic Channel


TCH[Erl] Traffic Connection Total time(DO 0)
Performance [Second]]+[DO A Traffic
Stat Channel Connection Total time
(DO A) [Second]]+[DO B
Traffic Channel Connection
Duration - 1 Carrier (DO B)
[Second]]+[DO B Traffic
Channel Connection Duration -
2 Carriers (DO B) [Second]]+
[DO B Traffic Channel
Connection Duration - 3
Carriers (DO B) [Second]])/
{GP}

Traffic Density on none EV-DOB [DO B Traffic Channel


TCH(DO B)[Erl] Carrier Connection Duration(DO B)
Traffic [Second]]/{GP}
Performance
Stat

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 365


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Ratio of Carriers with none CS Call Drop count((([DO 0 Traffic Channel


High Traffic on TCH Performance Connection Total time(DO 0)
[%] Stat [Second]]+[DO A Traffic
Channel Connection Total time
(DO A) [Second]]+[DO B
Traffic Channel Connection
Duration(DO B) [Second]])/
{GP})>22)/count(1=1)*{100}

Ratio of Carriers with none CS Call Drop count(([DO B Traffic Channel


High Traffic on TCH Performance Connection Duration(DO B)
(DO B)[%] Stat [Second]]/{GP})>22)/count
(1=1)*{100}

Network Soft HO Ratio[%] none EV-DO BSC ([DO A Traffic Channel CE


Coverage Traffic Total time(DO A) [Second]]+
Performance [DO 0 Traffic Channel CE
Stat Total time(DO 0) [Second]]+
[Traffic Channel CE Duration
(DO B) [Second]]-[DO A
Traffic Channel Connection
Total time(DO A) [Second]]-
[DO 0 Traffic Channel
Connection Total time(DO 0)
[Second]]-[DO B Traffic
Channel Connection Duration -
1 Carrier (DO B) [Second]]-
[DO B Traffic Channel
Connection Duration - 2
Carriers (DO B) [Second]]-
[DO B Traffic Channel
Connection Duration - 3
Carriers (DO B) [Second]])/
([DO A Traffic Channel CE
Total time(DO A) [Second]]+
[DO 0 Traffic Channel CE
Total time(DO 0) [Second]]+
[Traffic Channel CE Duration
(DO B) [Second]])*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 366


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Soft HO Ratio(DO none EV-DOB ([Traffic Channel CE Duration


B) BSC Traffic (DO B) [Second]]-[DO B
Performance Traffic Channel Connection
Stat Duration - 1 Carrier (DO B)
[Second]]-[DO B Traffic
Channel Connection Duration -
2 Carriers (DO B) [Second]]-
[DO B Traffic Channel
Connection Duration - 3
Carriers (DO B) [Second]])/
([Traffic Channel CE Duration
(DO B) [Second]])*{100}

Carrier Ratio of User none CS Call Drop count((([Access Times by


Forward Access with Performance Access Pilot Strength
Weak Pilot Strength Stat (-10.5,-31.5)[Times]]+[Access
[%] Times by Access Pilot Strength
(-7.5,-10)[Times]])/([Access
Times by Access Pilot Strength
(0,2)[Times]]+[Access Times
by Access Pilot Strength
(-2.5,-4.5)[Times]]+[Access
Times by Access Pilot Strength
(-5,-7)[Times]]+[Access
Times by Access Pilot Strength
(-10.5,-31.5)[Times]]+[Access
Times by Access Pilot Strength
(-7.5,-10)[Times]]))>0.1)/
count(1=1)*{100}

Resource Worst Carrier Ratio none CS Call Drop count(([Connection Requests


Usage [%] Performance [Times]]>100)and
Ratio Stat ((([Successful Connection
Times[Times]]/[Connection
Requests[Times]])*{100})
<0.96)or(((([Connection
release(RF lost)[Times]]+
[Connection release(Other
causes)[Times]]+[Connection
Release (HHO Fail)[Times]])/
[Successful Connection Times
[Times]])*{100})>0.03))/
count(1=1)*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 367


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Worst Carrier Ratio none CS Call Drop count((((([Successful


(DO B)[%] Performance Connection Times(DO B)
Stat [Times]]/[Connection
Requests(DO B)[Times]])*
{100})<0.96)and([DO B
Traffic Channel Connection
Duration(DO B) [Second]]/
{GP})>2.5))/count(1=1)*
{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

8.2.3 Service Integrity Report

BSC Service Integrity Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 368


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Service Forward Link Data % RLP -


Integrity Retransmission Rate Throughput
[%] Stat

Reverse Link Data % RLP -


Retransmission Rate Throughput
[%] Stat

Average Forward none DO TCH ([DO FTCH Forward RLP


Speed During of Forward RLP Layer Transmit Throughput
Connetion Hoding Throughput [byte]]+[DOB FTCH Forward
[kbps] Stat RLP Layer Transmit
Throughput[byte]])*{8}/
({GP}*{60}*([DO Average
Active User Count[entries]]+
[Average number of DOB
active service legs [entries]])*
{1000})

SAR Forward Link % RLP -


Data Retransmission Throughput
Rate (DOB) [%] Stat

RLP Reverse Link % RLP -


Data Retransmission Throughput
Rate (DOB) [%] Stat

Average Forward none DO TCH [DOB FTCH Forward RLP


Speed During of Forward RLP Layer Transmit Throughput
Connetion Hoding Throughput [byte]]*{8}/({GP}*{60}*
(DO B) Stat [Average number of DOB
active service legs [entries]]*
{1000})

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 369


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Single Carrier Avg Reverse Speed During DO Conn Hoding Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Average Average Reverse none Do Carrier [RLP Octets Received on


Reverse Speed During of DO Performance Reverse Channels[KB]]*
Speed Connetion Hoding Mesurement {1024}*{8}/(([DO Average
Active Connection Number
[entries]]+[Average number of
DOB active connections
[entries]])*{GP}*{1000})

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Single Carrier Ava Reverse Speed During DO Conn Hoding Report

Report Type
Simple Report

NE Type
CBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 370


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Object Type
CBSC Carrier

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Average Average Reverse none Do Carrier [RLP Octets Received on


Reverse Speed During of DO Performance Reverse Channels[KB]]*
Speed Connetion Hoding Mesurement {1024}*{8}/(([DO Average
BottomN Active Connection Number
[entries]]+[Average number of
DOB active connections
[entries]])*{GP}*{1000})

Average Forward none DO TCH ([DO FTCH Forward RLP


Speed During of DO Forward RLP Layer Transmit Throughput
Connetion Hoding Throughput [byte]]+[DOB FTCH Forward
Stat RLP Layer Transmit
Throughput[byte]])*{8}/
(([DO Average Active User
Count[entries]]+[Average
number of DOB active service
legs [entries]])*{GP}*{1000})

Traffic Drop Ratio none EV-DOB [DO B Traffic Channel


(DO B)[minute] Carrier Connection Duration(DO B)
Traffic [Second]]/(([Connection
Performance release(RF lost)(DO B)
Stat [Times]]+[Connection Release
(HHO Fail)(DO B)[Times]]+
[Connection release(Other
causes)(DO B)[Times]]-
[Connection Released
(Interoperation Between 1X
and DO)(DO B)[Times]])*
{60})

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 371


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Single Carrier Avg Forward Speed During DO Conn Hoding Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC Carrier

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Average Average Forward none DO TCH ([DO FTCH Forward RLP


Forward Speed During of DO Forward RLP Layer Transmit Throughput
Speed Connetion Hoding Throughput [byte]]+[DOB FTCH Forward
Stat RLP Layer Transmit
Throughput[byte]])*{8}/
(([DO Average Active User
Count[entries]]+[Average
number of DOB active service
legs [entries]])*{GP}*{1000})

Average DOB FTCH Forward byte DO TCH -


Forward RLP Layer Transmit Forward RLP
Speed Throughput[byte] Throughput
Stat

Average Average Forward none DO TCH ([DO FTCH Forward RLP


Forward Speed During of DO Forward RLP Layer Transmit Throughput
Speed Connetion Hoding Throughput [byte]]+[DOB FTCH Forward
BottomN Stat RLP Layer Transmit
Throughput[byte]])*{8}/
(([DO Average Active User
Count[entries]]+[Average
number of DOB active service
legs [entries]])*{GP}*{1000})

Average Reverse none Do Carrier [RLP Octets Received on


Speed During of DO Performance Reverse Channels[KB]]*
Connetion Hoding Mesurement {1024}*{8}/(([DO Average
[Times] Active Connection Number
[entries]]+[Average number of
DOB active connections
[entries]])*{GP}*{1000})

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 372


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Single Carrier Avg F-Speed During DO Conn Hoding Carrier Report

Report Type
Simple Report

NE Type
CBSC

Object Type
Carrier

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Average DOB FTCH Forward bytes DO TCH -


Forward RLP Layer Transmit Forward RLP
Speed Throughput[byte] Throughput
Stat

Average Average Forward no DO TCH ([DO FTCH Forward RLP


Forward Speed During of DO unit Forward RLP Layer Transmit Throughput
Speed Connetion Hoding Throughput [byte]]+[DOB FTCH Forward
BottomN Stat RLP Layer Transmit
Throughput[byte]])*{8}/
((([DO Average Active User
Count[entries]]+[Average
number of DOB active service
legs [entries]])*{GP}*
{1000}))

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 373


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Average Reverse no Do Carrier [RLP Octets Received on


Speed During of DO unit Performance Reverse Channels[KB]]*
Connetion Hoding Mesurement {1024}*{8}/((([DO Average
[Times] Active Connection Number
[entries]]+[Average number of
DOB active connections
[entries]])*{GP}*{1000}))

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Forward and Reverse Transmission Quality Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Forward Forward Link Data % RLP -


and Retransmission Rate Throughput
Reverse [%] Stat
Retransm
it Reverse Link Data % RLP -
Retransmission Rate Throughput
[%] Stat

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 374


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Forward SAR Forward Link % RLP -


Reverse Data Retransmission Throughput
Retransm Rate (DOB) [%] Stat
it(DOB)
RLP Reverse Link % RLP -
Data Retransmission Throughput
Rate (DOB) [%] Stat

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Carrier Forward and Reverse Transmission Quality Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC Carrier

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Forward Forward Link Data none DO TCH [DO FTCH Forward RLP
RLP Retransmission Rate Forward RLP Layer Retransmit Throughput
Retransm [%] Throughput [byte]]/[DO FTCH Forward
it TopN Stat RLP Layer Transmit
Throughput[byte]]*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 375


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

DO FTCH Forward none DO TCH -


RLP Layer Transmit Forward RLP
Throughput[byte] Throughput
Stat

DO FTCH Forward none DO TCH -


RLP Layer Forward RLP
Retransmit Throughput
Throughput[byte] Stat

Reverse Octets Resent on % Do Carrier [Octets Resent on request of


RLP request of AN Ratio Performance AN[Byte]]/[RLP Octets
Retransm Mesurement Received on Reverse Channels
it TopN [KB]]*{100}

RLP Octets Received kiloby Do Carrier -


on Reverse Channels tes Performance
[KB] Mesurement

Reverse repeat RLP byte Do Carrier -


Octets[Byte] Performance
Mesurement

Octets Resent on byte Do Carrier -


request of AN[Byte] Performance
Mesurement

RLP Octets Not kiloby Do Carrier -


Received on Reverse tes Performance
Channels[KB] Mesurement

Reverse Abort times Do Carrier -


[Times] Performance
Mesurement

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 376


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Carrier Forward Average Rate During Data Transmission Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC Carrier

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Forward User Forward none DO TCH ([DO FTCH Forward RLP


Feel Avg Average Feeling Forward RLP Layer Transmit Throughput
Rate Rate During Data Throughput [byte]]+[DOB FTCH Forward
BottomN Transmission[kbps] Stat RLP Layer Transmit
Throughput[byte]])*{8}/
([Evm Active Usage[entries]]*
{0.001667}*{1000})

Forward Average Forward none DO TCH ([DO FTCH Forward RLP


Avg Rate Speed During of DO Forward RLP Layer Transmit Throughput
BottomN Connetion Hoding Throughput [byte]]+[DOB FTCH Forward
Stat RLP Layer Transmit
Throughput[byte]])*{8}/
(([DO Average Active User
Count[entries]]+[Average
number of DOB active service
legs [entries]])*{GP}*{1000})

Average Reverse none Do Carrier [RLP Octets Received on


Speed During of DO Performance Reverse Channels[KB]]*
Connetion Hoding Mesurement {1024}*{8}/(([DO Average
Active Connection Number
[entries]]+[Average number of
DOB active connections
[entries]])*{GP}*{1000})

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 377


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Forward User Forward none DO TCH ([DO FTCH Forward RLP


Avg Feel Average Feeling Forward RLP Layer Transmit Throughput
Rate Rate During Data Throughput [byte]]+[DOB FTCH Forward
BottomN Transmission[kbps] Stat RLP Layer Transmit
Throughput[byte]])*{8}/
([Evm Active Usage[entries]]*
{0.001667}*{1000})

Average Forward none DO TCH ([DO FTCH Forward RLP


Speed During of DO Forward RLP Layer Transmit Throughput
Connetion Hoding Throughput [byte]]+[DOB FTCH Forward
Stat RLP Layer Transmit
Throughput[byte]])*{8}/
(([DO Average Active User
Count[entries]]+[Average
number of DOB active service
legs [entries]])*{GP}*{1000})

Average Reverse none Do Carrier [RLP Octets Received on


Speed During of DO Performance Reverse Channels[KB]]*
Connetion Hoding Mesurement {1024}*{8}/(([DO Average
Active Connection Number
[entries]]+[Average number of
DOB active connections
[entries]])*{GP}*{1000})

Forward Traffic Drop Ratio none EV-DOB [DO B Traffic Channel


Avg Rate (DO B)[minute] Carrier Connection Duration(DO B)
TopN Traffic [Second]]/(([Connection
Performance release(RF lost)(DO B)
Stat [Times]]+[Connection Release
(HHO Fail)(DO B)[Times]]+
[Connection release(Other
causes)(DO B)[Times]]-
[Connection Released
(Interoperation Between 1X
and DO)(DO B)[Times]])*
{60})

Average Forward none DO TCH ([DO FTCH Forward RLP


Speed During of DO Forward RLP Layer Transmit Throughput
Connetion Hoding Throughput [byte]]+[DOB FTCH Forward
Stat RLP Layer Transmit
Throughput[byte]])*{8}/
(([DO Average Active User
Count[entries]]+[Average
number of DOB active service
legs [entries]])*{GP}*{1000})

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 378


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Average Reverse none Do Carrier [RLP Octets Received on


Speed During of DO Performance Reverse Channels[KB]]*
Connetion Hoding Mesurement {1024}*{8}/(([DO Average
[Times] Active Connection Number
[entries]]+[Average number of
DOB active connections
[entries]])*{GP}*{1000})

Forward User Forward none DO TCH ([DO FTCH Forward RLP


Avg Feel Average Feeling Forward RLP Layer Transmit Throughput
Rate Rate During Data Throughput [byte]]+[DOB FTCH Forward
TopN Transmission[kbps] Stat RLP Layer Transmit
Throughput[byte]])*{8}/
([Evm Active Usage[entries]]*
{0.001667}*{1000})

Average Forward none DO TCH ([DO FTCH Forward RLP


Speed During of DO Forward RLP Layer Transmit Throughput
Connetion Hoding Throughput [byte]]+[DOB FTCH Forward
Stat RLP Layer Transmit
Throughput[byte]])*{8}/
(([DO Average Active User
Count[entries]]+[Average
number of DOB active service
legs [entries]])*{GP}*{1000})

Average Reverse none Do Carrier [RLP Octets Received on


Speed During of DO Performance Reverse Channels[KB]]*
Connetion Hoding Mesurement {1024}*{8}/(([DO Average
[Times] Active Connection Number
[entries]]+[Average number of
DOB active connections
[entries]])*{GP}*{1000})

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 379


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Carrier Service Integrity Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC Carrier

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Service Average Forward none DO TCH [DO FTCH Forward RLP


Integrity Speed During of Forward RLP Layer Transmit Throughput
Connetion Hoding Throughput [byte]]*{8}/({GP}*{60}*[DO
Stat Average Active User Count
[entries]]*{1000})

Forward Link Data none DO TCH [DO FTCH Forward RLP


Retransmission Rate Forward RLP Layer Retransmit Throughput
[%] Throughput [byte]]/[DO FTCH Forward
Stat RLP Layer Transmit
Throughput[byte]]*{100}

User Forward none DO TCH ([DO FTCH Forward RLP


Average Feeling Forward RLP Layer Transmit Throughput
Rate During Data Throughput [byte]]+[DOB FTCH Forward
Transmission[kbps] Stat RLP Layer Transmit
Throughput[byte]])*{8}/
([Evm Active Usage[entries]]*
{0.001667}*{1000})

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 380


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

8.2.4 Call Retainability Report

BSC Call Retainability KPI Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Call Connection Drop % Performance -


Retainabi Ratio[%] Stat of BSC
lity EV-DO
Connection
Release

Connection Drop % Performance -


Ratio(DO B)[%] Stat of BSC
EV-DO
Connection
Release

Traffic Drop Ratio none EV-DO BSC ([DO 0 Traffic Channel


[Minute] Traffic Connection Total time(DO 0)
Performance [Second]]+[DO A Traffic
Stat Channel Connection Total time
(DO A) [Second]])/
(([Connection Released (RF
lost)[Times]]+[Connection
Release (HHO Fail)[Times]]+
[Connection Released (Other
causes)[Times]])*{60})

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 381


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Traffic Drop Ratio none EV-DOB ([DO B Traffic Channel


(DO B)[minute] BSC Traffic Connection Duration - 1
Performance Carrier (DO B) [Second]]+[DO
Stat B Traffic Channel Connection
Duration - 2 Carriers (DO B)
[Second]]+[DO B Traffic
Channel Connection Duration -
3 Carriers (DO B) [Second]])/
(([Connection Released (RF
lost)(DO B)[Times]]+
[Connection Release (HHO
Fail)(DO B)[Times]]+
[Connection Released (Other
causes)(DO B)[Times]]-
[Connection Released
(Interoperation Between 1X
and DO)(DO B)[Times]])*
{60})

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Call Drop Ratio Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 382


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Call Connection Drop % Performance -


Drop Ratio[%] Stat of BSC
Ratio EV-DO
Connection
Release

Connection Drop % Performance -


Ratio(DO B)[%] Stat of BSC
EV-DO
Connection
Release

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Cause of Call Drops Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 383


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Cause of Connection Released times Performance -


Call (RF lost)[Times] Stat of BSC
Drops EV-DO
Connection
Release

Connection Released times Performance -


(Dormancy timer Stat of BSC
expired)[Times] EV-DO
Connection
Release

Connection Released times Performance -


(Dormancy timer Stat of BSC
expired without AT EV-DO
response)[Times] Connection
Release

Connection Released times Performance -


(Other causes) Stat of BSC
[Times] EV-DO
Connection
Release

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Carrier Cause of Call Drops Report

Report Type
Simple Report

NE Type
CBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 384


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Object Type
CBSC Carrier

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Call Connection Drop % Performance -


Drop Ratio[%] Stat of
Ratio Carrier EV-
TopN DO
Connection
Release

Connection Drop none EV-DOB [Connection release(RF lost)


[times] Carrier [Times]]+[Connection release
Traffic (Other causes)[Times]]+
Performance [Connection Release (HHO
Stat Fail)[Times]]

Normal Connection times Performance -


Release[Times] Stat of
Carrier EV-
DO
Connection
Release

Connection release times Performance -


(RF lost)[Times] Stat of
Carrier EV-
DO
Connection
Release

Connection release times Performance -


(Dormancy timer Stat of
expired)[Times] Carrier EV-
DO
Connection
Release

Connection release times Performance -


(Dormancy timer Stat of
expired without AT Carrier EV-
response)[Times] DO
Connection
Release

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 385


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Connection Release times Performance -


(HHO Fail)[Times] Stat of
Carrier EV-
DO
Connection
Release

Connection release times Performance -


(Other causes) Stat of
[Times] Carrier EV-
DO
Connection
Release

Call Connection Drop % Performance -


Drop Ratio(DO B)[%] Stat of
Ratio Carrier EV-
TopN DO
(DO B) Connection
Release

Connection Drop none EV-DOB [Connection release(RF lost)


(DO B)[times] Carrier (DO B)[Times]]+[Connection
Traffic Release (HHO Fail)(DO B)
Performance [Times]]+[Connection release
Stat (Other causes)(DO B)
[Times]]-[Connection
Released (Interoperation
Between 1X and DO)(DO B)
[Times]]

Normal Connection times Performance -


Release(DO B) Stat of
[Times] Carrier EV-
DO
Connection
Release

Connection release times Performance -


(RF lost)(DO B) Stat of
[Times] Carrier EV-
DO
Connection
Release

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 386


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Connection release times Performance -


(Dormancy timer Stat of
expired)(DO B) Carrier EV-
[Times] DO
Connection
Release

Connection Release times Performance -


(HHO Fail)(DO B) Stat of
[Times] Carrier EV-
DO
Connection
Release

Connection release times Performance -


(Other causes)(DO Stat of
B)[Times] Carrier EV-
DO
Connection
Release

Connection Released times Performance -


(Interoperation Stat of
Between 1X and DO) Carrier EV-
(DO B)[Times] DO
Connection
Release

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Carrier Call Retainability KPI Report

Report Type
Simple Report

NE Type
CBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 387


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Object Type
CBSC Carrier

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Call Connection Drop % Performance -


Retainabi Ratio[%] Stat of
lity Carrier EV-
DO
Connection
Release

Connection Drop % Performance -


Ratio(DO B)[%] Stat of
Carrier EV-
DO
Connection
Release

Traffic Drop Ratio none EV-DO ([DO 0 Traffic Channel


[Minute] Carrier Connection Total time(DO 0)
Traffic [Second]]+[DO A Traffic
Performance Channel Connection Total time
Stat (DO A) [Second]])/
(([Connection release(RF lost)
[Times]]+[Connection Release
(HHO Fail)[Times]]+
[Connection release(Other
causes)[Times]])*{60})

Traffic Drop Ratio none EV-DOB [DO B Traffic Channel


(DO B)[minute] Carrier Connection Duration(DO B)
Traffic [Second]]/(([Connection
Performance release(RF lost)(DO B)
Stat [Times]]+[Connection Release
(HHO Fail)(DO B)[Times]]+
[Connection release(Other
causes)(DO B)[Times]]-
[Connection Released
(Interoperation Between 1X
and DO)(DO B)[Times]])*
{60})

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 388


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

8.2.5 Accessibility Report

BSC Accessibility KPI Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Accessib Connection Success % Performance -


ility Ratio[%] Stat of BSC
EV-DO
Connection
Setup

Connection Success % Performance -


Ratio(DO B)[%] Stat of BSC
EV-DO
Connection
Setup

EV-DO Paging % Performance -


Success Ratio[%] Stat of BSC
HRPD
Sessions

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 389


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Connection Setup Success Ratio Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Connecti Connection Requests times Performance -


on Setup [Times] Stat of BSC
Success EV-DO
Ratio Connection
Setup

Connection Success % Performance -


Ratio[%] Stat of BSC
EV-DO
Connection
Setup

Connection Requests times Performance -


(DO B)[Times] Stat of BSC
EV-DO
Connection
Setup

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 390


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Connection Success % Performance -


Ratio(DO B)[%] Stat of BSC
EV-DO
Connection
Setup

Quick Quick Connection times Performance -


Conn Requests[Times] Stat of BSC
Setup EV-DO
Success Connection
Ratio Setup

Quick Connection % Performance -


Success Ratio[%] Stat of BSC
EV-DO
Connection
Setup

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Connection Setup Failures Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 391


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Conn Connection Failures none Performance [AN-Initiated Connection


Setup (Call Resource Stat of BSC Failures (Call resources
Failure Allocation Failures) EV-DO allocation failure)[Times]]+
Reason [Times] Connection [AT-Initiated Connection
Setup Failures (Call resources
allocation failure)[Times]]

Connection Failures none Performance [AN-Initiated Connection


(No R-TCH Stat of BSC Failures (No R-TCH Detected)
Detected)[Times] EV-DO [Times]]+[AT-initiated
Connection Connection Failures (No R-
Setup TCH Detected)[Times]]

Connection Failures none Performance [AN-Initiated Connection


(No Traffic Channel Stat of BSC Failures (No Traffic Channel
Complete received) EV-DO Complete received)[Times]]+
[Times] Connection [AT-Initiated Connection
Setup Failures (No Traffic Channel
Complete received)[Times]]

Connection Failures none Performance [AT-Initiated Connection


(MEID Connection Stat of BSC Failures (MEID Connection
rejected )[Times] EV-DO Reject)[Times]]+[AN-
Connection Initiated Connection Failures
Setup (MEID Connection Reject)
[Times]]

Connection Failures none Performance [AN-Initiated Connection


(other reason) Stat of BSC Failures (Other causes)
[Times] EV-DO [Times]]+[AT-Initiated
Connection Connection Failures (Other
Setup causes)[Times]]

Quick Quick Connection times Performance -


Conn Failures (Call Stat of BSC
Setup resources allocation EV-DO
Failure failure)[Times] Connection
Reason Setup

Quick Connection times Performance -


Failures (No R-TCH Stat of BSC
detected)[Times] EV-DO
Connection
Setup

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 392


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Quick Connection times Performance -


Failures (No Traffic Stat of BSC
Channel Complete EV-DO
received)[Times] Connection
Setup

Quick Connection times Performance -


Failures (MEID Stat of BSC
Connection Reject) EV-DO
[Times] Connection
Setup

Quick Connection times Performance -


Failures (Other Stat of BSC
causes)[Times] EV-DO
Connection
Setup

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Carrier Connection Setup Failures Causes Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC Carrier

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 393


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Conn Connection Success % Performance -


Setup Ratio[%] Stat of
Succ Carrier EV-
Ratio DO
BottomN Connection
Setup

Connection Requests times Performance -


[Times] Stat of
Carrier EV-
DO
Connection
Setup

Connection Failures none Performance [AN-Initiated Connection


(Call resources Stat of Failures (Call resources
allocation failure) Carrier EV- allocation failure)[Times]]+
[Times] DO [AT-Initiated Connection
Connection Failures (Call resources
Setup allocation failure)[Times]]

Connection Failures none Performance [AN-Initiated Connection


(No R-TCH Stat of Failures (No R-TCH Detected)
Detected)[Times] Carrier EV- [Times]]+[AT-initiated
DO Connection Failures (No R-
Connection TCH Detected)[Times]]
Setup

Connection Failures none Performance [AN-Initiated Connection


(No Traffic Channel Stat of Failures (No Traffic Channel
Complete received) Carrier EV- Complete received)[Times]]+
[Times] DO [AT-Initiated Connection
Connection Failures (No Traffic Channel
Setup Complete received)[Times]]

Connection Failures none Performance [AT-Initiated Connection


(MEID Connection Stat of Failures (MEID Connection
Reject)[Times] Carrier EV- Reject)[Times]]+[AN-
DO Initiated Connection Failures
Connection (MEID Connection Reject)
Setup [Times]]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 394


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Connection Failures none Performance [AN-Initiated Connection


(Other causes) Stat of Failures (Other causes)
[Times] Carrier EV- [Times]]+[AT-Initiated
DO Connection Failures (Other
Connection causes)[Times]]
Setup

Conn Connection Failures none Performance [Connection Requests


Setup Times[Times] Stat of [Times]]-[Successful
Failure Carrier EV- Connection Times[Times]]
Times DO
TopN Connection
Setup

Connection Success % Performance -


Ratio[%] Stat of
Carrier EV-
DO
Connection
Setup

Connection Failures none Performance [AN-Initiated Connection


(Call resources Stat of Failures (Call resources
allocation failure) Carrier EV- allocation failure)[Times]]+
[Times] DO [AT-Initiated Connection
Connection Failures (Call resources
Setup allocation failure)[Times]]

Connection Failures none Performance [AN-Initiated Connection


(No R-TCH Stat of Failures (No R-TCH Detected)
Detected)[Times] Carrier EV- [Times]]+[AT-initiated
DO Connection Failures (No R-
Connection TCH Detected)[Times]]
Setup

Connection Failures none Performance [AN-Initiated Connection


(No Traffic Channel Stat of Failures (No Traffic Channel
Complete received) Carrier EV- Complete received)[Times]]+
[Times] DO [AT-Initiated Connection
Connection Failures (No Traffic Channel
Setup Complete received)[Times]]

Connection Failures none Performance [AT-Initiated Connection


(MEID Connection Stat of Failures (MEID Connection
Reject)[Times] Carrier EV- Reject)[Times]]+[AN-
DO Initiated Connection Failures
Connection (MEID Connection Reject)
Setup [Times]]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 395


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Connection Failures none Performance [AN-Initiated Connection


(Other causes) Stat of Failures (Other causes)
[Times] Carrier EV- [Times]]+[AT-Initiated
DO Connection Failures (Other
Connection causes)[Times]]
Setup

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Connection Setup Duration Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Avg Connection Setup none CS Call Drop sum([Successful Connection


Conn Duration Performance Times[Times]]*[Connection
Setup Stat Setup Average Duration
Duration [Millisecond]])/sum
(([Successful Connection
Times[Times]]*[Connection
Setup Average Duration
[Millisecond]]))

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 396


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Successful times Performance -


Connection Times Stat of
[Times] Carrier EV-
DO
Connection
Setup

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Carrier Connection Setup Duration Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC Carrier

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Conn Connection Setup ms Performance -


Setup Average Duration Stat of
Duration [Millisecond] Carrier EV-
TopN DO
Connection
Setup

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 397


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Connection Requests times Performance -


[Times] Stat of
Carrier EV-
DO
Connection
Setup

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Paging Success Ratio Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Paging EV-DO Paging times Performance -


Success Attempts[Times] Stat of BSC
Ratio HRPD
Sessions

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 398


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

EV-DO Paging % Performance -


Success Ratio[%] Stat of BSC
HRPD
Sessions

Orig Orig times / Term none Performance [AN-Initiated Connection


Time to times[%] Stat of BSC Requests[Times]]/[AT-
Term EV-DO Initiated Connection Requests
Time Connection [Times]]
Ratio Setup

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Carrier Accessibility KPI Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC Carrier

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 399


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Accessib Connection Success % Performance -


ility Ratio[%] Stat of
Carrier EV-
DO
Connection
Setup

Connection Success % Performance -


Ratio(DO B)[%] Stat of
Carrier EV-
DO
Connection
Setup

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

8.2.6 Capacity Analysis Report

BSC Capacity Analysis KPI Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 400


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Capacity Forward RLP none Performance [Total RLP Octets Sent on


Analysis Throughput[Mbps] Stat of EV- Forward Channels[KB]]*{8}*
DO Service {1024}/{1000000}*{GP}
Data
Throughput

Reverse RLP none RLP [RLP Octets Received on


Throughput[Mbps] Throughput Reverse Channels[KB]]*{8}*
Stat {1024}/{1000000}*{GP}

Traffic Density on none EV-DO BSC ([DO 0 Traffic Channel


TCH[Erl] Traffic Connection Total time(DO 0)
Performance [Second]]+[DO A Traffic
Stat Channel Connection Total time
(DO A) [Second]]+[DO B
Traffic Channel Connection
Duration - 1 Carrier (DO B)
[Second]]+[DO B Traffic
Channel Connection Duration -
2 Carriers (DO B) [Second]]+
[DO B Traffic Channel
Connection Duration - 3
Carriers (DO B) [Second]])/
{GP}

Average Traffic none RLP (([SAR Octets Sent on Forward


Density on TCH of Throughput Channels(Excluding those
High-Load Carriers Stat Resent) (DO B) [KB]]*{8}+
[Erl] [SAR Octets Resent on
Forward Channels (DO B)
[Byte]]*{8})/{1000})/{GP}

Forward SAP none RLP ([SAR Octets Sent on Forward


Throughput (DO B) Throughput Channels(Excluding those
[Kbps] Stat Resent) (DO B) [KB]]*{8}+
[SAR Octets Resent on
Forward Channels (DO B)
[Byte]]*{8}/{1000})/{GP}

RLP Octets Received none RLP [RLP Octets Received on


on Reverse Channels Throughput Reverse Channels (DO B)
(DOB)[KB] Stat [KB]]*{8}/({GP}*{1000})

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 401


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Traffic Density on none EV-DOB ([DO B Traffic Channel


TCH(DO B) BSC Traffic Connection Duration - 1
Performance Carrier (DO B) [Second]]+[DO
Stat B Traffic Channel Connection
Duration - 2 Carriers (DO B)
[Second]]+[DO B Traffic
Channel Connection Duration -
3 Carriers (DO B) [Second]])/
{GP}

Access none Performance ([Access Authentication


Authentication Stat of BSC Attempts[Times]]-[Successful
Rejections(Other HRPD Access Authentications
causes)[%] Sessions [Times]]-[Access
Authentication Rejections
[Times]]-[Access
Authentication LCP
Negotiation Failure[Times]]-
[Access Authentication No
Resource[Times]])/([Access
Authentication Attempts
[Times]]-[Successful Access
Authentications[Times]])*
{100}

Ratio of Carriers with none CS Call Drop count((([DO 0 Traffic Channel


High Traffic on TCH Performance Connection Total time(DO 0)
[%] Stat [Second]]+[DO A Traffic
Channel Connection Total time
(DO A) [Second]]+[DO B
Traffic Channel Connection
Duration(DO B) [Second]])/
{GP})>22)/count(1=1)*{100}

Ratio of Carriers with none CS Call Drop count(([DO B Traffic Channel


High Traffic on TCH Performance Connection Duration(DO B)
(DO B)[%] Stat [Second]]/{GP})>22)/count
(1=1)*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 402


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Traffic Volume Analysis Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Traffic Traffic Density on none EV-DO BSC ([DO 0 Traffic Channel


(DO) TCH[Erl] Traffic Connection Total time(DO 0)
Performance [Second]]+[DO A Traffic
Stat Channel Connection Total time
(DO A) [Second]]+[DO B
Traffic Channel Connection
Duration - 1 Carrier (DO B)
[Second]]+[DO B Traffic
Channel Connection Duration -
2 Carriers (DO B) [Second]]+
[DO B Traffic Channel
Connection Duration - 3
Carriers (DO B) [Second]])/
{GP}

CE Traffic Density none EV-DO BSC ([DO 0 Traffic Channel CE


on TCH[Erl] Traffic Total time(DO 0) [Second]]+
Performance [DO A Traffic Channel CE
Stat Total time(DO A) [Second]]+
[Traffic Channel CE Duration
(DO B) [Second]])/{GP}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 403


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

MacIndex Traffic none EV-DO BSC ([DO 0 Traffic Channel


Density on TCH[Erl] Traffic MacIndex Total time(DO 0)
Performance [Second]]+[DO A Traffic
Stat Channel MacIndex Total time
(DO A) [Second]]+[Traffic
Channel MacIndex Duration
(DO B) [Second]])/{GP}

Traffic Traffic Density on none EV-DOB ([DO B Traffic Channel


(DOB) TCH(DO B) BSC Traffic Connection Duration - 1
Performance Carrier (DO B) [Second]]+[DO
Stat B Traffic Channel Connection
Duration - 2 Carriers (DO B)
[Second]]+[DO B Traffic
Channel Connection Duration -
3 Carriers (DO B) [Second]])/
{GP}

CE Traffic Density none EV-DOB [Traffic Channel CE Duration


on TCH(DO B)[Erl] BSC Traffic (DO B) [Second]]/{GP}
Performance
Stat

MacIndex Traffic none EV-DOB [Traffic Channel MacIndex


Density on TCH(DO BSC Traffic Duration (DO B) [Second]]/
B)[Erl] Performance {GP}
Stat

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Carrier Traffic Volume Analysis Report

Report Type
Simple Report

NE Type
CBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 404


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Object Type
CBSC Carrier

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Highest Traffic Density on none EV-DO ([DO 0 Traffic Channel


Traffic TCH[Erl] Carrier Connection Total time(DO 0)
on TCH Traffic [Second]]+[DO A Traffic
Performance Channel Connection Total time
Stat (DO A) [Second]]+[DO B
Traffic Channel Connection
Duration(DO B) [Second]])/
{GP}

Traffic Channel none EV-DO [DO 0 Traffic Channel


Connection Duration Carrier Connection Total time(DO 0)
[Second] Traffic [Second]]+[DO A Traffic
Performance Channel Connection Total time
Stat (DO A) [Second]]+[DO B
Traffic Channel Connection
Duration(DO B) [Second]]

Reverse CE Traffic none EV-DO ([DO 0 Traffic Channel CE


Density[Erl] Carrier Total time(DO 0) [Second]]+
Traffic [DO A Traffic Channel CE
Performance Total time(DO A) [Second]]+
Stat [DO B Traffic Channel CE
Duration (DO B) [Second]])/
{GP}

MacIndex Traffic none EV-DO ([DO 0 Traffic Channel


Density on TCH[Erl] Carrier MacIndex Total time(DO 0)
Traffic [Second]]+[DO A Traffic
Performance Channel MacIndex Total time
Stat (DO A) [Second]]+[DO B
Traffic Channel MacIndex
Duration (DO B) [Second]])/
{GP}

Max Active numb Performance -


Connectors of er Stat of
Carrier[Entries] Carrier EV-
DO
Connection
Release

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 405


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Highest Traffic Density on none EV-DOB [DO B Traffic Channel


Traffic TCH(DO B)[Erl] Carrier Connection Duration(DO B)
on TCH Traffic [Second]]/{GP}
(DO B) Performance
Stat

DO B Traffic s EV-DOB -
Channel Connection Carrier
Duration(DO B) Traffic
[Second] Performance
Stat

Reverse CE Traffic none EV-DOB [DO B Traffic Channel CE


Density(DO B) Carrier Duration (DO B) [Second]]/
Traffic {GP}
Performance
Stat

MacIndex Traffic none EV-DOB [DO B Traffic Channel


Density on TCH(DO Carrier MacIndex Duration (DO B)
B)[Erl] Traffic [Second]]/{GP}
Performance
Stat

Max Active numb Performance -


Connectors of er Stat of
Carrier[Entries] Carrier EV-
DO
Connection
Release

Lowest Traffic Density on none EV-DO ([DO 0 Traffic Channel


Traffic TCH[Erl] Carrier Connection Total time(DO 0)
on TCH Traffic [Second]]+[DO A Traffic
Performance Channel Connection Total time
Stat (DO A) [Second]]+[DO B
Traffic Channel Connection
Duration(DO B) [Second]])/
{GP}

Traffic Density on none EV-DOB [DO B Traffic Channel


TCH(DO B)[Erl] Carrier Connection Duration(DO B)
Traffic [Second]]/{GP}
Performance
Stat

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 406


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Reverse CE Traffic none EV-DO ([DO 0 Traffic Channel CE


Density[Erl] Carrier Total time(DO 0) [Second]]+
Traffic [DO A Traffic Channel CE
Performance Total time(DO A) [Second]]+
Stat [DO B Traffic Channel CE
Duration (DO B) [Second]])/
{GP}

MacIndex Traffic none EV-DO ([DO 0 Traffic Channel


Density on TCH[Erl] Carrier MacIndex Total time(DO 0)
Traffic [Second]]+[DO A Traffic
Performance Channel MacIndex Total time
Stat (DO A) [Second]]+[DO B
Traffic Channel MacIndex
Duration (DO B) [Second]])/
{GP}

Max Active numb Performance -


Connectors of er Stat of
Carrier[Entries] Carrier EV-
DO
Connection
Release

Lowest Traffic Density on none EV-DOB [DO B Traffic Channel


Traffic TCH(DO B)[Erl] Carrier Connection Duration(DO B)
on TCH Traffic [Second]]/{GP}
(DOB) Performance
Stat

DO B Traffic s EV-DOB -
Channel Connection Carrier
Duration(DO B) Traffic
[Second] Performance
Stat

Reverse CE Traffic none EV-DOB [DO B Traffic Channel CE


Density(DO B) Carrier Duration (DO B) [Second]]/
Traffic {GP}
Performance
Stat

MacIndex Traffic none EV-DOB [DO B Traffic Channel


Density on TCH(DO Carrier MacIndex Duration (DO B)
B)[Erl] Traffic [Second]]/{GP}
Performance
Stat

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 407


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Max Active numb Performance -


Connectors of er Stat of
Carrier[Entries] Carrier EV-
DO
Connection
Release

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Channel Load Analysis Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC Carrier

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

CCH DO CCH Average none DO CCH [DO CCH Average


Load Slot Occupancy Using Ratio Synchronous Packet
Ratio[%] Performance Occupancy Ratio[%]]+[DO
Stat CCH Average Sub-
Synchronous Packet
Occupancy Ratio[%]]+[DO
CCH Average Asynchronous
Packet Occupancy Ratio[%]]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 408


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

DO CCH Average none DO CCH -


Synchronous Packet Using Ratio
Occupancy Ratio[%] Performance
Stat

DO CCH Average none DO CCH -


Sub-Synchronous Using Ratio
Packet Occupancy Performance
Ratio[%] Stat

DO CCH Average none DO CCH -


Asynchronous Using Ratio
Packet Occupancy Performance
Ratio[%] Stat

DO CCH Discarded none DO CCH -


Sync Message Ratio Discard
[%] Performance
Stat

DO CCH Discarded none DO CCH -


Asynchronous Discard
Message Ratio[%] Performance
Stat

DO ACH DO ACH Average none DO ACH -


Load Slot Occupancy performance
Analysis Raito[%] Stat

DO ACH Maximum none DO ACH -


Slot Occupancy performance
Raito[%] Stat

DO ACH Minimum % DO ACH -


Slot Occupancy performance
Raito[%] Stat

DO ACH Average none DO ACH -


Collision Occupancy performance
Raito[%] Stat

DO ACH Maximum none DO ACH -


Collision Occupancy performance
Raito[%] Stat

DO ACH Minimum % DO ACH -


Collision Occupancy performance
Raito[%] Stat

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 409


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Forward DO TCH Average none DO TCH -


Load Slot Occupancy Load
Ratio[0.01%] Performance
Stat

DO TCH Maximum none DO TCH -


Slot Occupancy Load
Ratio[0.01%] Performance
Stat

DO FTCH Forward none DO TCH -


RLP Layer Transmit Forward RLP
Throughput[byte] Throughput
Stat

Traffic Density on none EV-DO ([DO 0 Traffic Channel


TCH[Erl] Carrier Connection Total time(DO 0)
Traffic [Second]]+[DO A Traffic
Performance Channel Connection Total time
Stat (DO A) [Second]]+[DO B
Traffic Channel Connection
Duration(DO B) [Second]])/
{GP}

DOB FTCH Forward byte DO TCH -


RLP Layer Transmit Forward RLP
Throughput[byte] Throughput
Stat

Reverse DO TCH Average none DO TCH -


Load ROT[1/8db] Load
Performance
Stat

DO TCH Maximum none DO TCH -


ROT[1/8db] Load
Performance
Stat

DO TCH Minimum none DO TCH -


ROT[1/8db] Load
Performance
Stat

DO TCH Reverse none DO TCH -


Load[1/8db] Load
Performance
Stat

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 410


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Service Data Throughput Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Forward Forward RLP none RLP [RLP Octets Sent on Forward


Reverse Throughput[MB] Throughput Channels(Excluding those
RLP Stat resent)[KB]]/{1000}+[RLP
Through Octets Resent on Forward
put Channels[Byte]]/{1000000}

Reverse RLP none RLP [RLP Octets Received on


Throughput[MB] Throughput Reverse Channels[KB]]/
Stat {1000}

Forw and Forward RLP none RLP [SAR Octets Sent on Forward
Reve Throughput(DO B) Throughput Channels(Excluding those
Through [MB] Stat Resent) (DO B) [KB]]/{1000}
put +[SAR Octets Resent on
(DOB) Forward Channels (DO B)
[Byte]]/{1000000}

Reverse RLP none RLP [RLP Octets Received on


Throughput(DO B) Throughput Reverse Channels (DO B)
[MB] Stat [KB]]/{1000}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 411


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Carrier Order by Service Data Throughput Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC Carrier

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Max DO FTCH Forward none DO TCH [DO FTCH Forward RLP


Forward RLP Layer Transmit Forward RLP Layer Transmit Throughput
RLP Throughput[KB] Throughput [byte]]/{1000}
Through Stat
put
DO FTCH Forward none DO TCH [DO FTCH Forward RLP
RLP Layer Forward RLP Layer Retransmit Throughput
Retransmit Throughput [byte]]/{1000}
Throughput[KB] Stat

Max DOB FTCH Forward byte DO TCH -


Forward RLP Layer Transmit Forward RLP
RLP Throughput[byte] Throughput
Through Stat
put
(DOB) DOB FTCH Forward none DO TCH [DOB FTCH Forward RLP
SAR Layer Forward RLP Layer Retransmit Throughput
Retransmit Throughput [byte]]*{8}/{1000}
Throughput[KB] Stat

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 412


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Min DO FTCH Forward none DO TCH [DO FTCH Forward RLP


Forward RLP Layer Transmit Forward RLP Layer Transmit Throughput
RLP Throughput[KB] Throughput [byte]]/{1000}
Through Stat
put
DO FTCH Forward none DO TCH [DO FTCH Forward RLP
RLP Layer Forward RLP Layer Retransmit Throughput
Retransmit Throughput [byte]]/{1000}
Throughput[KB] Stat

Min DOB FTCH Forward byte DO TCH -


Forward RLP Layer Transmit Forward RLP
RLP Throughput[byte] Throughput
Through Stat
put
(DOB) DOB FTCH Forward none DO TCH [DOB FTCH Forward RLP
SAR Layer Forward RLP Layer Retransmit Throughput
Retransmit Throughput [byte]]*{8}/{1000}
Throughput[KB] Stat

Max RLP Octets Received kiloby Do Carrier -


Reverse on Reverse Channels tes Performance
RLP [KB] Mesurement
Through
put Reverse repeat RLP none Do Carrier [Reverse repeat RLP Octets
Octets[KB] Performance [Byte]]/{1000}
Mesurement

Octets Resent on none Do Carrier [Octets Resent on request of


request of AN[KB] Performance AN[Byte]]/{1000}
Mesurement

RLP Octets Not kiloby Do Carrier -


Received on Reverse tes Performance
Channels[KB] Mesurement

Reverse Abort times Do Carrier -


[Times] Performance
Mesurement

Max RLP Octets Received kiloby Do Carrier -


Reverse on Reverse Channels tes Performance
RLP (DO B) [KB] Mesurement
Through
put Reverse repeat RLP none Do Carrier [Reverse repeat RLP Octets
(DOB) Octets[KB] Performance [Byte]]/{1000}
Mesurement

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 413


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Octets Resent on none Do Carrier [Octets Resent on request of


request of AN[KB] Performance AN[Byte]]/{1000}
Mesurement

RLP Octets Not kiloby Do Carrier -


Received on Reverse tes Performance
Channels[KB] Mesurement

Reverse Abort times Do Carrier -


[Times] Performance
Mesurement

Min RLP Octets Received kiloby Do Carrier -


Reverse on Reverse Channels tes Performance
RLP [KB] Mesurement
Through
put Reverse repeat RLP none Do Carrier [Reverse repeat RLP Octets
Octets[KB] Performance [Byte]]/{1000}
Mesurement

Octets Resent on none Do Carrier [Octets Resent on request of


request of AN[KB] Performance AN[Byte]]/{1000}
Mesurement

RLP Octets Not kiloby Do Carrier -


Received on Reverse tes Performance
Channels[KB] Mesurement

Reverse Abort times Do Carrier -


[Times] Performance
Mesurement

Min RLP Octets Received kiloby Do Carrier -


Reverse on Reverse Channels tes Performance
RLP (DO B) [KB] Mesurement
Through
put Reverse repeat RLP none Do Carrier [Reverse repeat RLP Octets
(DOB) Octets[KB] Performance [Byte]]/{1000}
Mesurement

Octets Resent on none Do Carrier [Octets Resent on request of


request of AN[KB] Performance AN[Byte]]/{1000}
Mesurement

RLP Octets Not kiloby Do Carrier -


Received on Reverse tes Performance
Channels[KB] Mesurement

Reverse Abort times Do Carrier -


[Times] Performance
Mesurement

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 414


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Carrier Capability KPI Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC Carrier

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Capacity Traffic Density on none EV-DO ([DO 0 Traffic Channel


Analysis TCH[Erl] Carrier Connection Total time(DO 0)
Traffic [Second]]+[DO A Traffic
Performance Channel Connection Total time
Stat (DO A) [Second]]+[DO B
Traffic Channel Connection
Duration(DO B) [Second]])/
{GP}

Carrier Forward RLP none DO TCH ([DO FTCH Forward RLP


Throughput[byte] Forward RLP Layer Transmit Throughput
Throughput [byte]]+[DO FTCH Forward
Stat RLP Layer Retransmit
Throughput[byte]]+[DOB
FTCH Forward RLP Layer
Transmit Throughput[byte]]+
[DOB FTCH Forward RLP
Layer Retransmit Throughput
[byte]])*{8}/{1000}*{GP}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 415


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

DO TCH Average none DO TCH [DO TCH Average Slot


Slot Occupancy Load Occupancy Ratio[0.01%]]/
Ratio[%] Performance {100}
Stat

DO CCH Average none DO CCH [DO CCH Average


Slot Occupancy Using Ratio Synchronous Packet
Ratio[%] Performance Occupancy Ratio[%]]+[DO
Stat CCH Average Sub-
Synchronous Packet
Occupancy Ratio[%]]+[DO
CCH Average Asynchronous
Packet Occupancy Ratio[%]]

DO ACH Average none DO ACH -


Slot Occupancy performance
Raito[%] Stat

Reverse RLP none Do Carrier [RLP Octets Received on


Throughput[kbps] Performance Reverse Channels[KB]]*{8}/
Mesurement {GP}

Capacity Traffic Density on none EV-DOB [DO B Traffic Channel


Analysis TCH(DO B)[Erl] Carrier Connection Duration(DO B)
(DO B) Traffic [Second]]/{GP}
Performance
Stat

Forward SAP none DO TCH ([DOB FTCH Forward RLP


Throughput (DO B) Forward RLP Layer Transmit Throughput
[Kbps] Throughput [byte]]+[DOB FTCH Forward
Stat RLP Layer Retransmit
Throughput[byte]])*{8}/
({1000}*{GP})

Reverse RLP none Do Carrier [RLP Octets Received on


Throughput (DO B) Performance Reverse Channels (DO B)
[Kbps] Mesurement [KB]]*{8}/({GP}*{1000})

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 416


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

8.2.7 Network Coverage Analysis Report

BSC Network Coverage Analysis KPI Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 417


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Network Soft HO Ratio[%] none EV-DO BSC ([DO A Traffic Channel CE


Coverage Traffic Total time(DO A) [Second]]+
Analysis Performance [DO 0 Traffic Channel CE
Stat Total time(DO 0) [Second]]+
[Traffic Channel CE Duration
(DO B) [Second]]-[DO A
Traffic Channel Connection
Total time(DO A) [Second]]-
[DO 0 Traffic Channel
Connection Total time(DO 0)
[Second]]-[DO B Traffic
Channel Connection Duration -
1 Carrier (DO B) [Second]]-
[DO B Traffic Channel
Connection Duration - 2
Carriers (DO B) [Second]]-
[DO B Traffic Channel
Connection Duration - 3
Carriers (DO B) [Second]])/
([DO A Traffic Channel CE
Total time(DO A) [Second]]+
[DO 0 Traffic Channel CE
Total time(DO 0) [Second]]+
[Traffic Channel CE Duration
(DO B) [Second]])*{100}

Soft HO Ratio(DO none EV-DOB ([Traffic Channel CE Duration


B) BSC Traffic (DO B) [Second]]-[DO B
Performance Traffic Channel Connection
Stat Duration - 1 Carrier (DO B)
[Second]]-[DO B Traffic
Channel Connection Duration -
2 Carriers (DO B) [Second]]-
[DO B Traffic Channel
Connection Duration - 3
Carriers (DO B) [Second]])/
([Traffic Channel CE Duration
(DO B) [Second]])*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 418


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Carrier Ratio of User none CS Call Drop count((([Access Times by


Forward Access with Performance Access Pilot Strength
Weak Pilot Strength Stat (-10.5,-31.5)[Times]]+[Access
[%] Times by Access Pilot Strength
(-7.5,-10)[Times]])/([Access
Times by Access Pilot Strength
(0,2)[Times]]+[Access Times
by Access Pilot Strength
(-2.5,-4.5)[Times]]+[Access
Times by Access Pilot Strength
(-5,-7)[Times]]+[Access
Times by Access Pilot Strength
(-10.5,-31.5)[Times]]+[Access
Times by Access Pilot Strength
(-7.5,-10)[Times]]))>0.1)/
count(1=1)*{100}

Ratio of Carriers with none CS Call Drop count(if([Main RSSI Average


Reverse Link Performance Value[0.1dBm]]>[Div RSSI
Interference[%] Stat Average Value[0.1dBm]],
[Main RSSI Average Value
[0.1dBm]],[Div RSSI Average
Value[0.1dBm]])>-98)/count
(1=1)*{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

RSSI Analysis Report

Report Type
Simple Report

NE Type
CBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 419


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Object Type
CBSC Carrier

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Carrier Main RSSI Average none RSSI -


order by Value[0.1dBm] Performance
Main Stat
RSSI
Desc Div RSSI Average none RSSI -
Value[0.1dBm] Performance
Stat

Carrier Div RSSI Average none RSSI -


order by Value[0.1dBm] Performance
Div RSSI Stat
Desc
Main RSSI Average none RSSI -
Value[0.1dBm] Performance
Stat

Main and Difference Between none RSSI [Main RSSI Average Value
Div RSSI Main And Diversity Performance [0.1dBm]]-[Div RSSI Average
Diff Desc RSSI Average Value Stat Value[0.1dBm]]

Main RSSI Average none RSSI -


Value[0.1dBm] Performance
Stat

Div RSSI Average none RSSI -


Value[0.1dBm] Performance
Stat

Carrier Main RSSI Average none RSSI -


order by Value[0.1dBm] Performance
Main Stat
RSSI Asc
Div RSSI Average none RSSI -
Value[0.1dBm] Performance
Stat

Carrier Main RSSI Average none RSSI -


order by Value[0.1dBm] Performance
Div RSSI Stat
Asc
Div RSSI Average none RSSI -
Value[0.1dBm] Performance
Stat

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 420


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Forward Pilot the RouteUpdate Pilot Strength Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Pilot Access Times by none EV-DO BSC [Access Times by Access Pilot
Strength Access Pilot Strength Cover Strength(0,2)[Times]]/
Proportio (-0,-2) Ratio[%] Performance ([Access Times by Access Pilot
n Stat of Strength(0,2)[Times]]+
Access State [Access Times by Access Pilot
Strength(-2.5,-4.5)[Times]]+
[Access Times by Access Pilot
Strength(-5,-7)[Times]]+
[Access Times by Access Pilot
Strength(-7.5,-10)[Times]]+
[Access Times by Access Pilot
Strength(-10.5,-31.5)[Times]])
*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 421


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Access Times by none EV-DO BSC [Access Times by Access Pilot


Access Pilot Strength Cover Strength(-2.5,-4.5)[Times]]/
(-2.5,-4.5) Ratio[%] Performance ([Access Times by Access Pilot
Stat of Strength(0,2)[Times]]+
Access State [Access Times by Access Pilot
Strength(-2.5,-4.5)[Times]]+
[Access Times by Access Pilot
Strength(-5,-7)[Times]]+
[Access Times by Access Pilot
Strength(-7.5,-10)[Times]]+
[Access Times by Access Pilot
Strength(-10.5,-31.5)[Times]])
*{100}

Access Times by none EV-DO BSC [Access Times by Access Pilot


Access Pilot Strength Cover Strength(-5,-7)[Times]]/
(-5,-7) Ratio[%] Performance ([Access Times by Access Pilot
Stat of Strength(0,2)[Times]]+
Access State [Access Times by Access Pilot
Strength(-2.5,-4.5)[Times]]+
[Access Times by Access Pilot
Strength(-5,-7)[Times]]+
[Access Times by Access Pilot
Strength(-7.5,-10)[Times]]+
[Access Times by Access Pilot
Strength(-10.5,-31.5)[Times]])
*{100}

Access Times by none EV-DO BSC [Access Times by Access Pilot


Access Pilot Strength Cover Strength(-7.5,-10)[Times]]/
(-7.5,-10)Ratio Performance ([Access Times by Access Pilot
Stat of Strength(0,2)[Times]]+
Access State [Access Times by Access Pilot
Strength(-2.5,-4.5)[Times]]+
[Access Times by Access Pilot
Strength(-5,-7)[Times]]+
[Access Times by Access Pilot
Strength(-7.5,-10)[Times]]+
[Access Times by Access Pilot
Strength(-10.5,-31.5)[Times]])
*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 422


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Access Times by none EV-DO BSC [Access Times by Access Pilot


Access Pilot Strength Cover Strength(-10.5,-31.5)[Times]]/
(-10.5,-31.5)[Times] Performance ([Access Times by Access Pilot
Stat of Strength(0,2)[Times]]+
Access State [Access Times by Access Pilot
Strength(-2.5,-4.5)[Times]]+
[Access Times by Access Pilot
Strength(-5,-7)[Times]]+
[Access Times by Access Pilot
Strength(-7.5,-10)[Times]]+
[Access Times by Access Pilot
Strength(-10.5,-31.5)[Times]])
*{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Analysis of the Soft Handoff Proportion Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 423


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Soft Soft HO Ratio[%] none EV-DO BSC ([DO A Traffic Channel CE


Handoff Traffic Total time(DO A) [Second]]+
Ratio Performance [DO 0 Traffic Channel CE
Stat Total time(DO 0) [Second]]+
[Traffic Channel CE Duration
(DO B) [Second]]-[DO A
Traffic Channel Connection
Total time(DO A) [Second]]-
[DO 0 Traffic Channel
Connection Total time(DO 0)
[Second]]-[DO B Traffic
Channel Connection Duration -
1 Carrier (DO B) [Second]]-
[DO B Traffic Channel
Connection Duration - 2
Carriers (DO B) [Second]]-
[DO B Traffic Channel
Connection Duration - 3
Carriers (DO B) [Second]])/
([DO A Traffic Channel CE
Total time(DO A) [Second]]+
[DO 0 Traffic Channel CE
Total time(DO 0) [Second]]+
[Traffic Channel CE Duration
(DO B) [Second]])*{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Carrier Analysis of the Soft Handoff Proportion TopN Report

Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 424


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NE Type
CBSC

Object Type
CBSC Carrier

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Soft Soft Handoff Ratio none EV-DO BSC {100}*([DO 0 Traffic Channel
Handoff [%] Traffic CE Total time(DO 0) [Second]]
Ratio Performance +[DO A Traffic Channel CE
Desc Stat Total time(DO A) [Second]]+
[DO B Traffic Channel CE
Duration (DO B) [Second]]-
[DO 0 Traffic Channel
Connection Total time(DO 0)
[Second]]-[DO A Traffic
Channel Connection Total time
(DO A) [Second]]-[DO B
Traffic Channel Connection
Duration(DO B) (Below Nine-
Legs)[Second]])/([DO 0
Traffic Channel CE Total time
(DO 0) [Second]]+[DO A
Traffic Channel CE Total time
(DO A) [Second]]+[DO B
Traffic Channel CE Duration
(DO B) [Second]])

DO Traffic Channel none EV-DO BSC [DO 0 Traffic Channel


Seizure Total time Traffic Connection Total time(DO 0)
Performance [Second]]+[DO A Traffic
Stat Channel Connection Total time
(DO A) [Second]]+[DO B
Traffic Channel Connection
Duration(DO B) (Below Nine-
Legs)[Second]]

CE Seizure Total none EV-DO BSC [DO 0 Traffic Channel CE


time[Second] Traffic Total time(DO 0) [Second]]+
Performance [DO A Traffic Channel CE
Stat Total time(DO A) [Second]]+
[DO B Traffic Channel CE
Duration (DO B) [Second]]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 425


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Soft Soft Handoff Ratio none EV-DO BSC {100}*([DO 0 Traffic Channel
Handoff [%] Traffic CE Total time(DO 0) [Second]]
Ratio Performance +[DO A Traffic Channel CE
Asc Stat Total time(DO A) [Second]]+
[DO B Traffic Channel CE
Duration (DO B) [Second]]-
[DO 0 Traffic Channel
Connection Total time(DO 0)
[Second]]-[DO A Traffic
Channel Connection Total time
(DO A) [Second]]-[DO B
Traffic Channel Connection
Duration(DO B) (Below Nine-
Legs)[Second]])/([DO 0
Traffic Channel CE Total time
(DO 0) [Second]]+[DO A
Traffic Channel CE Total time
(DO A) [Second]]+[DO B
Traffic Channel CE Duration
(DO B) [Second]])

DO Traffic Channel none EV-DO BSC [DO 0 Traffic Channel


Seizure Total time Traffic Connection Total time(DO 0)
Performance [Second]]+[DO A Traffic
Stat Channel Connection Total time
(DO A) [Second]]+[DO B
Traffic Channel Connection
Duration(DO B) (Below Nine-
Legs)[Second]]

CE Seizure Total none EV-DO BSC [DO 0 Traffic Channel CE


time[Second] Traffic Total time(DO 0) [Second]]+
Performance [DO A Traffic Channel CE
Stat Total time(DO A) [Second]]+
[DO B Traffic Channel CE
Duration (DO B) [Second]]

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 426


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Carrier Access Times by Average Pilot Strength TopN Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC Carrier

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Avg Pilot Access Times by times EV-DO -


Strength Access Pilot Strength Carrier
Proportio (0,2)[Times] Cover
n Performance
Stat of
Access State

Access Times by times EV-DO -


Access Pilot Strength Carrier
(-2.5,-4.5)[Times] Cover
Performance
Stat of
Access State

Access Times by times EV-DO -


Access Pilot Strength Carrier
(-5,-7)[Times] Cover
Performance
Stat of
Access State

Access Times by times EV-DO -


Access Pilot Strength Carrier
(-7.5,-10)[Times] Cover
Performance
Stat of
Access State

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 427


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Access Times by times EV-DO -


Access Pilot Strength Carrier
(-10.5,-31.5)[Times] Cover
Performance
Stat of
Access State

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

8.2.8 Mobility Report

Inter-AN Hard Handoff Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Inter-AN Successful Inter-AN none Performance {100}*[Successful Inter-AN


HHO Incoming Hard HOs Stat of Inter- Incoming Hard HOs[Times]]/
Incoming Ratio[%] AN Hard HO [Inter-AN Incoming Hard HO
Outgoing Requests[Times]]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 428


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Successful Inter-AN none Performance {100}*[Successful Inter-AN


Hard HOs Ratio[%] Stat of Inter- Hard HOs[Times]]/[Inter-AN
AN Hard HO Hard HO Requests[Times]]

Inter-AN Successful Inter-AN none Performance [Successful Inter-AN


HHO Incoming Hard HOs Stat of Inter- Incoming Hard HOs(DO B)
Income Ratio(DO B) AN Hard HO [Times]]/[Inter-AN Incoming
Outgo Hard HO Requests(DO B)
(DOB) [Times]]*{100}

Successful Inter-AN none Performance {100}*[Successful Inter-AN


Hard HOs Ratio(DO Stat of Inter- Hard HOs(DO B)[Times]]/
B) AN Hard HO [Inter-AN Hard HO Requests
(DO B)[Times]]

Inter-AN Inter-AN Incoming times Performance -


HHO Hard HOs Failures Stat of Inter-
Incoming (Resource Allocation AN Hard HO
Fail Failed)[Times]

Inter-AN Incoming times Performance -


Hard HOs Failures Stat of Inter-
(HO Execution AN Hard HO
Failed)[Times]

Inter-AN Incoming times Performance -


Hard HOs Failures Stat of Inter-
(Other causes) AN Hard HO
[Times]

Inter-AN Inter-AN Hard HO times Performance -


HHO Failures (Radio Stat of Inter-
Outcgoin resources AN Hard HO
g Fail unavailable)[Times]

Inter-AN Hard HO times Performance -


Failures (Requested Stat of Inter-
terrestrial resources AN Hard HO
unavailable)[Times]

Inter-AN Hard HO times Performance -


Failures (MS Not Stat of Inter-
detected by AN Hard HO
destination pilot)
[Times]

Inter-AN Hard HO times Performance -


Failures (Other Stat of Inter-
causes)[Times] AN Hard HO

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 429


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Carrier Inter-AN Hard Handoff Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC Carrier

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Inter-AN Successful Inter-AN none Performance {100}*[Successful Inter-AN


HHO Incoming Hard HOs Stat of Incoming Hard HOs[Times]]/
Incoming Ratio[%] Carrier Inter- [Inter-AN Incoming Hard HO
Success AN Hard HO Requests[Times]]

Inter-AN Incoming times Performance -


Hard HO Requests Stat of
[Times] Carrier Inter-
AN Hard HO

Inter-AN Incoming times Performance -


Hard HOs Failures Stat of
(Resource Allocation Carrier Inter-
Failed)[Times] AN Hard HO

Inter-AN Incoming times Performance -


Hard HOs Failures Stat of
(HO Execution Carrier Inter-
Failed)[Times] AN Hard HO

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 430


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Inter-AN Incoming times Performance -


Hard HOs Failures Stat of
(Other causes) Carrier Inter-
[Times] AN Hard HO

Incoming Successful Inter-AN none Performance {100}*[Successful Inter-AN


Success Incoming Hard HOs Stat of Incoming Hard HOs(DO B)
BottomN Ratio(DO B) Carrier Inter- [Times]]/[Inter-AN Incoming
(DOB) AN Hard HO Hard HO Requests(DO B)
[Times]]

Inter-AN Incoming times Performance -


Hard HO Requests Stat of
(DO B)[Times] Carrier Inter-
AN Hard HO

Inter-AN Incoming times Performance -


Hard HOs Failures Stat of
(HO Execution Carrier Inter-
Failed)[Times] AN Hard HO

Inter-AN Incoming times Performance -


Hard HOs Failures Stat of
(Other causes) Carrier Inter-
[Times] AN Hard HO

Successful Inter-AN times Performance -


Incoming Hard HOs Stat of
[Times] Carrier Inter-
AN Hard HO

Outgoing Successful Inter-AN none Performance {100}*[Successful Inter-AN


Success Hard HOs Ratio[%] Stat of Hard HOs[Times]]/[Inter-AN
BottomN Carrier Inter- Hard HO Requests[Times]]
AN Hard HO

Successful Inter-AN times Performance -


Hard HOs[Times] Stat of
Carrier Inter-
AN Hard HO

Inter-AN Hard HO times Performance -


Failures (Radio Stat of
resources Carrier Inter-
unavailable)[Times] AN Hard HO

Inter-AN Hard HO times Performance -


Failures (Requested Stat of
terrestrial resources Carrier Inter-
unavailable)[Times] AN Hard HO

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 431


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Inter-AN Hard HO times Performance -


Failures (MS Not Stat of
detected by Carrier Inter-
destination pilot) AN Hard HO
[Times]

Inter-AN Hard HO times Performance -


Failures (Other Stat of
causes)[Times] Carrier Inter-
AN Hard HO

Outgoing Successful Inter-AN none Performance {100}*[Successful Inter-AN


Success Outgoing Hard HO Stat of Hard HOs(DO B)[Times]]/
BottomN Ratio(DO B)[%] Carrier Inter- [Inter-AN Hard HO Requests
(DOB) AN Hard HO (DO B)[Times]]

Inter-AN Hard HO times Performance -


Requests(DO B) Stat of
[Times] Carrier Inter-
AN Hard HO

Inter-AN Hard HO times Performance -


Failures (Radio Stat of
resources Carrier Inter-
unavailable)[Times] AN Hard HO

Inter-AN Hard HO times Performance -


Failures (Requested Stat of
terrestrial resources Carrier Inter-
unavailable)[Times] AN Hard HO

Inter-AN Hard HO times Performance -


Failures (MS Not Stat of
detected by Carrier Inter-
destination pilot) AN Hard HO
[Times]

Inter-AN Hard HO times Performance -


Failures (Other Stat of
causes)[Times] Carrier Inter-
AN Hard HO

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 432


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Intra-AN Hard Handoff Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Intra-BS Intra-AN Hard HO times Performance -


HHO Requests[Times] Stat of Intra-
Success AN Hard HO
Ratio
Intra-AN Hard HO % Performance -
Success Ratio[%] Stat of Intra-
AN Hard HO

Intra-AN Hard HO times Performance -


Requests(DO B) Stat of Intra-
[Times] AN Hard HO

Intra-AN Hard HO % Performance -


Success Ratio(DO B) Stat of Intra-
[%] AN Hard HO

Intra-BS Intra-AN Hard HO times Performance -


HHO Failures (Radio Stat of Intra-
Failures resources AN Hard HO
Causes unavailable)[Times]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 433


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Intra-AN Hard HO times Performance -


Failures (Requested Stat of Intra-
terrestrial resources AN Hard HO
unavailable)[Times]

Intra-AN Hard HO times Performance -


Failures (MS Not Stat of Intra-
detected by AN Hard HO
destination pilot)
[Times]

Intra-AN Hard HO times Performance -


Failures (Other Stat of Intra-
causes)[Times] AN Hard HO

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Intra-AN Hard Handoff Worst Carrier Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC Carrier

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 434


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Intra-BS Intra-AN Hard HO % Performance -


HHO Success Ratio[%] Stat of
SuccR Carrier Intra-
BottomN AN Hard HO

Intra-AN Hard HO times Performance -


Requests[Times] Stat of
Carrier Intra-
AN Hard HO

Intra-AN Hard HO times Performance -


Failures (Radio Stat of
resources Carrier Intra-
unavailable)[Times] AN Hard HO

Intra-AN Hard HO times Performance -


Failures (Requested Stat of
terrestrial resources Carrier Intra-
unavailable)[Times] AN Hard HO

Intra-AN Hard HO times Performance -


Failures (MS Not Stat of
detected by Carrier Intra-
destination pilot) AN Hard HO
[Times]

Intra-AN Hard HO times Performance -


Failures (Other Stat of
causes)[Times] Carrier Intra-
AN Hard HO

Intra-BS Intra-AN Hard HO % Performance -


HHO Success Ratio(DO B) Stat of
SuccR [%] Carrier Intra-
BottomN AN Hard HO
(DO B)
Intra-AN Hard HO times Performance -
Requests(DO B) Stat of
[Times] Carrier Intra-
AN Hard HO

Intra-AN Hard HO times Performance -


Failures (Radio Stat of
resources Carrier Intra-
unavailable)[Times] AN Hard HO

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 435


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Intra-AN Hard HO times Performance -


Failures (Requested Stat of
terrestrial resources Carrier Intra-
unavailable)[Times] AN Hard HO

Intra-AN Hard HO times Performance -


Failures (MS Not Stat of
detected by Carrier Intra-
destination pilot) AN Hard HO
[Times]

Intra-AN Hard HO times Performance -


Failures (Other Stat of
causes)[Times] Carrier Intra-
AN Hard HO

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

BSC Mobility KPI Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 436


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Mobility Intra-BS Soft HO % Performance -


Analysis Success Ratio[%] Stat of BSC
KPI EV-DO
Reverse
Channel Soft
HO

Intra-AN Hard HO % Performance -


Success Ratio[%] Stat of Intra-
AN Hard HO

Successful Intra- none Performance {100}*[Successful Inter-


subnet HOs between Stat of BSC subnet HOs within same AN
ANs Ratio[%] HRPD [Times]]/[Inter-subnet HO
Sessions (within same AN) Attempts
[Times]]

Inter-AN inter - none Performance [Successful Inter-subnet HOs


subnet HO Success Stat of BSC between ANs[Times]]/[Inter-
Ratio[%] HRPD subnet HO (between ANs)
Sessions Attempts[Times]]*{100}

Successful Inter-AN none Performance [Successful Inter-AN


Incoming Hard HOs Stat of Inter- Incoming Hard HOs(DO B)
Ratio(DO B) AN Hard HO [Times]]/[Inter-AN Incoming
Hard HO Requests(DO B)
[Times]]*{100}

Successful Inter-AN none Performance [Successful Inter-AN Hard


Hard HOs Ratio Stat of Inter- HOs(DO B)[Times]]/[Inter-
(DOB) AN Hard HO AN Hard HO Requests(DO B)
[Times]]*{100}

Location Update none Performance ([Location Update Assignment


Assignment Success Stat of BSC (Location Assignment Sent)
Ratio[%] HRPD [Times]]-[Location Update
Sessions Uncompletion(No Location
Complete Received)[Times]])
*{100}/[Location Update
Attempts(Location
Notification Received)
[Times]]*{100}

A13 Session % Performance -


Information Query Stat of BSC
Success Ratio[%] HRPD
Sessions

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 437


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Intra-AN Hard HO % Performance -


Success Ratio(DO B) Stat of Intra-
[%] AN Hard HO

Successful Inter-AN none Performance {100}*[Successful Inter-AN


Incoming Hard HOs Stat of Inter- Incoming Hard HOs[Times]]/
Ratio[%] AN Hard HO [Inter-AN Incoming Hard HO
Requests[Times]]

Successful Inter-AN none Performance {100}*[Successful Inter-AN


Hard HOs Ratio[%] Stat of Inter- Hard HOs[Times]]/[Inter-AN
AN Hard HO Hard HO Requests[Times]]

PS of Call Release times PS Call Drop -


Num Performance
Stat

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Inter-BS Soft Handoff Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 438


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Inter-BS Inter-BS Soft HO % Performance -


SHO Success Ratio(DO B) Stat of BSC
Success [%] EV-DO
Ratio Reverse
Channel Soft
HO

Inter-BS Soft HO times Performance -


Requests (DO B) Stat of BSC
[Times] EV-DO
Reverse
Channel Soft
HO

Inter-BS Soft HO none Performance [Inter-BS Soft HO requests-


Requests Times Stat of BSC Add Leg EV-DO[Times]]+
[Times] EV-DO [Inter-BS Soft HO requests-
Reverse Del Leg EV-DO[Times]]
Channel Soft
HO

Inter-BS Soft HO none Performance ([Successful Inter-BS Soft


Success [%] Stat of BSC Hos-Add Leg EV-DO[Times]]
EV-DO +[Successful Inter-BS Soft
Reverse Hos-Del Leg EV-DO
Channel Soft [Times]])/([Inter-BS Soft HO
HO requests-Add Leg EV-DO
[Times]]+[Inter-BS Soft HO
requests-Del Leg EV-DO
[Times]])*{100}

Inter-BS Inter-BS Soft HO times Performance -


SHO Failures (Radio Stat of BSC
Failures resources EV-DO
Causes unavailable) EV-DO Reverse
[Times] Channel Soft
HO

Inter-BS Soft HO times Performance -


Failures (Requested Stat of BSC
Abis resources EV-DO
unavailable) EV-DO Reverse
[Times] Channel Soft
HO

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 439


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Inter-BS Soft HO times Performance -


Failures (Radio Stat of BSC
interface abnormal) EV-DO
EV-DO[Times] Reverse
Channel Soft
HO

Inter-BS Soft HO times Performance -


Failures (MS Stat of BSC
rejected) EV-DO EV-DO
[Times] Reverse
Channel Soft
HO

Inter-BS Soft HO times Performance -


Failures (A17/A18 Stat of BSC
link setup failed) EV- EV-DO
DO[Times] Reverse
Channel Soft
HO

Inter-BS Soft HO times Performance -


Failures (Other Stat of BSC
causes) EV-DO EV-DO
[Times] Reverse
Channel Soft
HO

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Intra-BS Soft Handoff Report

Report Type
Simple Report

NE Type
CBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 440


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Intra-BS Intra-BS Soft HO % Performance -


SHO Success Ratio[%] Stat of BSC
Success EV-DO
Ratio Reverse
Channel Soft
HO

Intra-BS Soft HO times Performance -


requests EV-DO Stat of BSC
[Times] EV-DO
Reverse
Channel Soft
HO

Intra-BS Soft HO % Performance -


Success Ratio(DO B) Stat of BSC
[%] EV-DO
Reverse
Channel Soft
HO

Intra-BS Soft HO times Performance -


Requests (DO B) Stat of BSC
[Times] EV-DO
Reverse
Channel Soft
HO

Intra-BS Intra-BS Soft HO times Performance -


SHO Failures (Radio Stat of BSC
Failures resources EV-DO
Causes unavailable) EV-DO Reverse
[Times] Channel Soft
HO

Intra-BS Soft HO times Performance -


Failures (Requested Stat of BSC
Abis resources EV-DO
unavailable)[Times] Reverse
Channel Soft
HO

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 441


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Intra-BS Soft HO times Performance -


Failures (Radio Stat of BSC
interface abnormal) EV-DO
[Times] Reverse
Channel Soft
HO

Intra-BS Soft HO times Performance -


Failures (Other Stat of BSC
causes)[Times] EV-DO
Reverse
Channel Soft
HO

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Carrier Intra-BS Soft Handoff Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC Carrier

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 442


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Intra-BS Intra-BS Soft HO % Performance -


SHO Success Ratio[%] Stat of
SuccR Carrier EV-
BottomN DO Reverse
Channel Soft
HO

Intra-BS Soft HO times Performance -


requests EV-DO Stat of
[Times] Carrier EV-
DO Reverse
Channel Soft
HO

Intra-BS Soft HO times Performance -


Failures (Radio Stat of
resources Carrier EV-
unavailable) EV-DO DO Reverse
[Times] Channel Soft
HO

Intra-BS Soft HO times Performance -


Failures (Requested Stat of
Abis resources Carrier EV-
unavailable)[Times] DO Reverse
Channel Soft
HO

Intra-BS Soft HO times Performance -


Failures (Radio Stat of
interface abnormal) Carrier EV-
[Times] DO Reverse
Channel Soft
HO

Intra-BS Soft HO times Performance -


Failures (Other Stat of
causes)[Times] Carrier EV-
DO Reverse
Channel Soft
HO

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 443


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Intra-BS Intra-BS Soft HO % Performance -


SHO Success Ratio(DO B) Stat of
SuccR [%] Carrier EV-
BottomN DO Reverse
(DOB) Channel Soft
HO

Intra-BS Soft HO times Performance -


Requests (DO B) Stat of
[Times] Carrier EV-
DO Reverse
Channel Soft
HO

Intra-BS Soft HO times Performance -


Failures (Radio Stat of
resources Carrier EV-
unavailable) EV-DO DO Reverse
[Times] Channel Soft
HO

Intra-BS Soft HO times Performance -


Failures (Requested Stat of
Abis resources Carrier EV-
unavailable)[Times] DO Reverse
Channel Soft
HO

Intra-BS Soft HO times Performance -


Failures (Radio Stat of
interface abnormal) Carrier EV-
[Times] DO Reverse
Channel Soft
HO

Intra-BS Soft HO times Performance -


Failures (Other Stat of
causes)[Times] Carrier EV-
DO Reverse
Channel Soft
HO

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 444


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

HRPD Session Transfer and Location Update Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Transfer Inter-AN inter - none Performance [Successful Inter-subnet HOs


and subnet HO Success Stat of BSC between ANs[Times]]/[Inter-
Location Ratio[%] HRPD subnet HO (between ANs)
Update Sessions Attempts[Times]]*{100}

A13 Session % Performance -


Information Query Stat of BSC
Success Ratio[%] HRPD
Sessions

Location Update none Performance ([Location Update Assignment


Assignment Success Stat of BSC (Location Assignment Sent)
Ratio[%] HRPD [Times]]-[Location Update
Sessions Uncompletion(No Location
Complete Received)[Times]])
*{100}/[Location Update
Attempts(Location
Notification Received)
[Times]]*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 445


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Carrier Mobility KPI Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC Carrier

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Mobility Intra-BS Soft HO % Performance -


Analysis Success Ratio[%] Stat of
KPI Carrier EV-
DO Reverse
Channel Soft
HO

Intra-AN Hard HO % Performance -


Success Ratio[%] Stat of
Carrier Intra-
AN Hard HO

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 446


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

8.2.9 Resource Utilization Analysis Report

Forward High Load of Abis Analysis Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBTS

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Forward Average Total kiloby BTS3606 -


High Bandwidth Occupied tes/ Abis Link
Load of by Forward 1x and secon Resource
Abis DO Services Shared d Performance
Abis Link [kbps] Stat

Average Total kiloby BTS3606 -


Bandwidth Occupied tes/ Abis Link
by Forward DO secon Resource
Service Dedicated d Performance
Abis Link [kbps] Stat

Duration of Forward s BTS3606 -


1X and DO Services Abis Link
Shared Abis Link Resource
with Bandwidth Performance
Usage 81%-90% [s] Stat

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 447


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Duration of Forward s BTS3606 -


1X and DO Services Abis Link
Shared Abis Link Resource
with Bandwidth Performance
Usage 71%-80% [s] Stat

Duration of Forward s BTS3606 -


1X and DO Services Abis Link
Shared Abis Link Resource
with Bandwidth Performance
Usage 61%-70% [s] Stat

Duration of Forward s BTS3606 -


1X and DO Services Abis Link
Shared Abis Link Resource
with Bandwidth Performance
Usage 31%-60% [s] Stat

Duration of Forward s BTS3606 -


1X and DO Services Abis Link
Shared Abis Link Resource
with Bandwidth Performance
Usage 0%-30% [s] Stat

UBRI0 Max CPU % BTS3606 -


Occupation Ratio[%] Board CPU
Occupancy
Performance
Stat

Duration of Forward s BTS3900 -


DO Service CDMA Abis
Dedicated Abis Link Link
with Bandwidth Resource
Usage 91%-100% [s] Performance
Stat

Duration of Forward s BTS3900 -


DO Service CDMA Abis
Dedicated Abis Link Link
with Bandwidth Resource
Usage 81%-90% [s] Performance
Stat

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 448


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Duration of Forward s BTS3900 -


DO Service CDMA Abis
Dedicated Abis Link Link
with Bandwidth Resource
Usage 71%-80% [s] Performance
Stat

Duration of Forward s BTS3900 -


DO Service CDMA Abis
Dedicated Abis Link Link
with Bandwidth Resource
Usage 61%-70% [s] Performance
Stat

Duration of Forward s BTS3900 -


DO Service CDMA Abis
Dedicated Abis Link Link
with Bandwidth Resource
Usage 31%-60% [s] Performance
Stat

Duration of Forward s BTS3900 -


DO Service CDMA Abis
Dedicated Abis Link Link
with Bandwidth Resource
Usage 0%-30% [s] Performance
Stat

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

BSC CSPU CPU Utilization Report

Report Type
Simple Report

NE Type
CBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 449


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

CSPU CSPU CPU Load[%] % CSPU CPU -


CPU Performance
Utilizatio Stat
n

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

BSC Resource Utilization Analysis KPI Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 450


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Worst Worst Carrier Ratio none CS Call Drop count(([Connection Requests


Carrier [%] Performance [Times]]>100)and
Ratio Stat ((([Successful Connection
Times[Times]]/[Connection
Requests[Times]])*{100})
<0.96)or(((([Connection
release(RF lost)[Times]]+
[Connection release(Other
causes)[Times]]+[Connection
Release (HHO Fail)[Times]])/
[Successful Connection Times
[Times]])*{100})>0.03))/
count(1=1)*{100}

Worst Worst Carrier Ratio none CS Call Drop count((((([Successful


Carrier (DO B)[%] Performance Connection Times(DO B)
Ratio Stat [Times]]/[Connection
(DO B) Requests(DO B)[Times]])*
{100})<0.96)and([DO B
Traffic Channel Connection
Duration(DO B) [Second]]/
{GP})>2.5))/count(1=1)*
{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

BTS DO CEResource Utilization Report

Report Type
Simple Report

NE Type
CBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 451


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Object Type
CBSC Carrier

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Resource DO Average Reverse none DO Channel -


Utilizatio Channels Occupation Element
n Ratio By Common Performance
Channels Per Stat
Resource Pool
[entries]

DO Max Reverse none DO Channel -


Channels Occupation Element
Ratio By Common Performance
Channels Per Stat
Resource Pool
[entries]

DO Max Available none DO Channel -


Reverse Channels By Element
Channels Per Performance
Resource Pool Stat
[entries]

DO Min Available none DO Channel -


Reverse Channels By Element
Channels Per Performance
Resource Pool Stat
[entries]

DO Max Reverse none DO Channel -


Channels Occupied Element
By Traffic Channels Performance
Per Resource Pool Stat
[entries]

DO Average Reverse none DO Channel -


Channels Occupied Element
By Traffic Channels Performance
Per Resource Pool Stat
[entries]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 452


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

DO Max Forward none DO Channel -


Channels Occupied Element
By Common Performance
Channels Per Stat
Resource Pool
[entries]

DO Average Reverse none DO Channel -


Channels Occupied Element
By Common Performance
Channels Per Stat
Resource Pool
[entries]

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

BTS DO MacIndex Resource Utilization Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC Carrier

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 453


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Resource DO Average none DO Channel -


Utilizatio Forward MacIndexs Element
n Occupation Ratio By Performance
Traffic Channels Stat
[entries]

DO Max Forward none DO Channel -


MacIndexs Element
Occupation Ratio By Performance
Traffic Channels Stat
[entries]

DO Available none DO Channel -


Forward MacIndexs Element
per sector carrier Performance
[entries] Stat

DO Max Forward none DO Channel -


MacIndexs Occupied Element
By Traffic Channels Performance
per sector carrier Stat
[entries]

DO Average none DO Channel -


Forward MacIndexs Element
Occupied By Traffic Performance
Channels Per sector Stat
carrier[entries]

DO Max Forward none DO Channel -


MacIndexs Occupied Element
By Common Performance
Channels Per sector Stat
carrier[entries]

DO Average none DO Channel -


Forward MacIndexs Element
Occupied By Performance
Common Channels Stat
Per sector carrier
[entries]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 454


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

BTS Resource Utilization Analysis KPI Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Resource Average Total none BTS3606 [Average Total Bandwidth


Utilizatio Bandwidth Occupied Abis Link Occupied by Forward DO
n by Forward DO Resource Service Dedicated Abis Link
Service Dedicated Performance [kbps]]/[Average Total
Abis Link [kbps]/ Stat Bandwidth Occupied by
Average Total Forward 1x and DO Services
Bandwidth Occupied Shared Abis Link [kbps]]*
by Reverse DO {100}
Service Dedicated
Abis Link [kbps]

Average Total none BTS3606 [Average Total Bandwidth


Bandwidth Occupied Abis Link Occupied by Reverse 1x and
by Forward 1x and Resource DO Services Shared Abis Link
DO Services Shared Performance [kbps]]/[Average Total
Abis Link [kbps]/ Stat Bandwidth Occupied by
Average Total Reverse DO Service Dedicated
Bandwidth Occupied Abis Link [kbps]]*{100}
by Reverse 1x and
DO Services Shared
Abis Link [kbps]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 455


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

CBTS3606 Rank of BTSs by Reverse Congestion of Abis Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Reverse Abis Link Rvs Do s BTS3606 -


Congesti Congestion Abis Link
on of Continuance[s] Congestion
Abis Performance
Stat

Abis Link Rvs Do times BTS3606 -


Congestion Num Abis Link
[times] Congestion
Performance
Stat

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 456


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

CBTS3606 ABTSs in Desc Order by FER of Abis Link TopN Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

FER of Average PER Of All % BTS3606 -


the Abis Abis Link[10e-7] Abis Link
Link Quality
TopN Performance
Stat

Max Value Of Single % BTS3606 -


Abis Link Average Abis Link
PER[10e-7] Quality
Performance
Stat

Abis Link Max PER % BTS3606 -


[10e-7] Abis Link
Quality
Performance
Stat

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 457


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

CBTS3606 BTSs by Interruption Duration of Abis Link TopN Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Interrupti Abis Link Interrupt times BTS3606 -


on Times[times] Abis Link
Duration Quality
Performance
Stat

Abis Link Interrupt s BTS3606 -


Continuance[s] Abis Link
Quality
Performance
Stat

Abis Link Avail s BTS3606 -


Continuance[s] Abis Link
Quality
Performance
Stat

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 458


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Abis Link Max s BTS3606 -


Interrupt Abis Link
Continuance[s] Quality
Performance
Stat

Abis Do Signal Link times BTS3606 -


Interrupt Times Abis Link
[times] Quality
Performance
Stat

Abis Om Link times BTS3606 -


Interrupt Times Abis Link
[times] Quality
Performance
Stat

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

CBTS3900 Rank of BTSs by Reverse Congestion of Abis Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 459


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Reverse Abis Link Rvs Do s BTS3900 -


Congesti Congestion CDMA Abis
on of Continuance[s] Link
Abis Congestion
Performance
Stat

Abis Link Rvs Do times BTS3900 -


Congestion Num CDMA Abis
[times] Link
Congestion
Performance
Stat

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

CBTS3900 ABTSs in Desc Order by FER of Abis Link TopN Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 460


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

FER of Average PER Of All % BTS3900 -


the Abis Abis Link[10e-7] CDMA Abis
Link Link Quality
TopN Performance
Stat

Max Value Of Single % BTS3900 -


Abis Link's Average CDMA Abis
PER[10e-7] Link Quality
Performance
Stat

Abis Link Max PER % BTS3900 -


[10e-7] CDMA Abis
Link Quality
Performance
Stat

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

CBTS3900 BTSs by Interruption Duration of Abis Link TopN Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 461


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Interrupti Abis Link Interrupt times BTS3900 -


on Times[times] CDMA Abis
Duration Link Quality
Performance
Stat

Abis Link Interrupt s BTS3900 -


Continuance[s] CDMA Abis
Link Quality
Performance
Stat

Abis Link Avail s BTS3900 -


Continuance[s] CDMA Abis
Link Quality
Performance
Stat

Abis Link Max s BTS3900 -


Interrupt CDMA Abis
Continuance[s] Link Quality
Performance
Stat

Abis Do Signal Link times BTS3900 -


Interrupt Times CDMA Abis
[times] Link Quality
Performance
Stat

Abis Om Link times BTS3900 -


Interrupt Times CDMA Abis
[times] Link Quality
Performance
Stat

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 462


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Frame Resource Utilization Analysis KPI Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Resource CSPU CPU Load[%] % CSPU CPU -


Utilizatio Performance
n Stat

Worst Carrier Ratio none CS Call Drop count((((([Successful


(DO B)[%] Performance Connection Times(DO B)
Stat [Times]]/[Connection
Requests(DO B)[Times]])*
{100})<0.96)and([DO B
Traffic Channel Connection
Duration(DO B) [Second]]/
{GP})>2.5))/count(1=1)*
{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Carrier Resource Utilization Analysis KPI Report

Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 463


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NE Type
CBSC

Object Type
CBSC Carrier

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Resource DO Average Reverse none DO Channel -


Utilizatio Channels Occupation Element
n Ratio By Common Performance
Channels Per Stat
Resource Pool
[entries]

DO Average none DO Channel -


Forward MacIndexs Element
Occupation Ratio By Performance
Traffic Channels Stat
[entries]

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

8.3 CBSC-DO Performance Report

8.3.1 Service Integrality Report

Forward and Reverse Transmision Quality Report

Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 464


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NE Type
CBSC

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Forward Forward Link Data % RLP {100}*([Octets Resent on


and Retransmission Rate Throughput request of AT[Byte]]/({1024}*
Reverse [%] Stat [Total RLP Octets Sent on
RLP Forward Channels[KB]]))
Layer
Retransm Reverse Link Data % RLP {100}*([Octets Resent on
it Retransmission Rate Throughput request of AN[Byte]]/({1024}
[%] Stat *[RLP Octets Received on
Reverse Channels[KB]]))

Octets Octets Resent on % Do Carrier [Octets Resent on request of


Resent request of AN Ratio Performance AN[Byte]]/[RLP Octets
on Mesurement Received on Reverse Channels
Request [KB]]*{100}
of AN
Ratio RLP Octets Received kiloby Do Carrier -
on Reverse Channels tes Performance
[KB] Mesurement

Reverse repeat RLP byte Do Carrier -


Octets[Byte] Performance
Mesurement

Octets Resent on byte Do Carrier -


request of AN[Byte] Performance
Mesurement

RLP Octets Not kiloby Do Carrier -


Received on Reverse tes Performance
Channels[KB] Mesurement

Reverse Abort times Do Carrier -


[Times] Performance
Mesurement

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 465


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

DO FTCH Forward RLP Layer Retransmit Ratio Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBTS

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Carrier Forward Link Data none DO TCH [DO FTCH Forward RLP
order by Retransmission Rate Forward RLP Layer Retransmit Throughput
DO [%] Throughput [byte]]/[DO FTCH Forward
FTCH Stat RLP Layer Transmit
Forward Throughput[byte]]*{100}
RLP
Layer DO FTCH Forward none DO TCH -
Retransm RLP Layer Transmit Forward RLP
it Ratio Throughput[byte] Throughput
Desc Stat

DO FTCH Forward none DO TCH -


RLP Layer Forward RLP
Retransmit Throughput
Throughput[byte] Stat

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 466


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

8.3.2 Call Holding Report

Connection Drop Trend Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

BSC Connection Drop % Performance (([Connection Released (RF


Connecti Ratio[%] Stat of BSC lost)[Times]]+[Connection
on Drop EV-DO Released (Other causes)
Ratio Connection [Times]])/[Successful
Release Connection Times[Times]])*
{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 467


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

8.3.3 HRPD Session Report

HRPD Session Setup Scale Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

HRPD Maximum HRPD numb Performance -


Session Sessions[Entries] er Stat of BSC
Number HRPD
and Sessions
Subscrib
e Active Minimum HRPD numb Performance -
Ratio Sessions[Entries] er Stat of BSC
HRPD
Sessions

Maximum number of numb Performance -


active HRPD er Stat of BSC
Sessions[Entries] HRPD
Sessions

Minimum number of numb Performance -


active HRPD er Stat of BSC
Sessions[Entries] HRPD
Sessions

Subscribe Active % Performance ([Maximum number of active


Ratio Stat of BSC HRPD Sessions[Entries]]+
HRPD [Minimum number of active
Sessions HRPD Sessions[Entries]])/
([Maximum HRPD Sessions
[Entries]]+[Minimum HRPD
Sessions[Entries]])

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 468


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

HRPD Session Setup Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

BSC HRPD Session Setup % Performance ([Successful HRPD Session


Session Success Ratio[%] Stat of BSC setup[Times]]/[HRPD Session
Setup HRPD setup Requests[Times]])*
Success Sessions {100}
Ratio
HRPD Session setup times Performance -
Requests[Times] Stat of BSC
HRPD
Sessions

HRPD HRPD Session none Performance [HRPD Session attemp


Session attemp Failures(No Stat of BSC Failures(No HardwareID
Setup HardwareID Request HRPD Request Sent)[Times]]/[HRPD
Failure Sent) Ratio Sessions Session attempt Failure
[Times]]*{100}

HRPD Session none Performance [HRPD Session attemp


attemp Failures(No Stat of BSC Failures(No UATIAssignment
UATIAssignment HRPD Sent)[Times]]/[HRPD Session
Sent) Ratio Sessions attempt Failure[Times]]*
{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 469


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

HRPD Session none Performance [HRPD Session attemp


attemp Failures(No Stat of BSC Failures(No HardwareID
HardwareID HRPD Response Received)[Times]]/
Response Received) Sessions [HRPD Session attempt Failure
Ratio [Times]]*{100}

HRPD Session none Performance [HRPD Session attemp


attemp Failures(No Stat of BSC Failures(No UATIComplete
UATIComplete HRPD Received)[Times]]/[HRPD
Received) Ratio Sessions Session attempt Failure
[Times]]*{100}

Carrier HRPD Session Setup % Performance ([Successful HRPD Session


Session Success Ratio[%] Stat of setup[Times]]/[HRPD Session
Setup Carrier setup Requests[Times]])*
HRPD {100}
Sessions

HRPD Session setup times Performance -


Requests[Times] Stat of
Carrier
HRPD
Sessions

HRPD Session times Performance -


attemp Failures(No Stat of
HardwareID Request Carrier
Sent)[Times] HRPD
Sessions

HRPD Session times Performance -


attemp Failures(No Stat of
UATIAssignment Carrier
Sent)[Times] HRPD
Sessions

HRPD Session times Performance -


attemp Failures(No Stat of
HardwareID Carrier
Response Received) HRPD
[Times] Sessions

HRPD Session times Performance -


attemp Failures(No Stat of
UATIComplete Carrier
Received)[Times] HRPD
Sessions

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 470


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

HRPD Session Setup Release Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

HRPD HRPD Session times Performance [HRPD Session Released from


Session Released from AN Stat of BSC AN(Source AN release in inter
Released HRPD AN handoff)[Times]]+[HRPD
from AT Sessions Session Released from AN
and AN (Release old session in session
setup)[Times]]+[HRPD
Session Released from AN
(Keep alive timer expired)
[Times]]+[HRPD Session
Released from AN(Authority
failed)[Times]]+[HRPD
Session Released from AN
(Configure failed)[Times]]+
[HRPD Session Released from
AN(Others)[Times]]+[HRPD
Session Released from AN
(MML operated)[Times]]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 471


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

HRPD Session none Performance [HRPD Session Released from


Released from AT Stat of BSC AT(Normal closed)[Times]]+
HRPD [HRPD Session Released from
Sessions AT(Protocol error)[Times]]+
[HRPD Session Released from
AT(Protocol configuration
failure)[Times]]+[HRPD
Session Released from AT
(Protocol negotiation error)
[Times]]+[HRPD Session
Released from AT(Session
configuration failure)[Times]]
+[HRPD Session Released
from AT(Others)[Times]]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 472


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

HRPD HRPD Session % Performance [HRPD Session Released from


Session Released from AT Stat of BSC AT(Normal closed)[Times]]/
Released (Normal closed) HRPD (([HRPD Session Released
Reason Ratio Sessions from AT(Normal closed)
[Times]]+[HRPD Session
Released from AT(Protocol
error)[Times]]+[HRPD
Session Released from AT
(Protocol configuration failure)
[Times]]+[HRPD Session
Released from AT(Protocol
negotiation error)[Times]]+
[HRPD Session Released from
AT(Session configuration
failure)[Times]]+[HRPD
Session Released from AT
(Others)[Times]])+([HRPD
Session Released from AN
(Source AN release in inter AN
handoff)[Times]]+[HRPD
Session Released from AN
(Release old session in session
setup)[Times]]+[HRPD
Session Released from AN
(Keep alive timer expired)
[Times]]+[HRPD Session
Released from AN(Authority
failed)[Times]]+[HRPD
Session Released from AN
(Configure failed)[Times]]+
[HRPD Session Released from
AN(Others)[Times]]+[HRPD
Session Released from AN
(MML operated)[Times]]))*
{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 473


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

HRPD Session % Performance [HRPD Session Released from


Released from AT Stat of BSC AT(Protocol negotiation error)
(Protocol negotiation HRPD [Times]]/(([HRPD Session
error) Ratio Sessions Released from AT(Normal
closed)[Times]]+[HRPD
Session Released from AT
(Protocol error)[Times]]+
[HRPD Session Released from
AT(Protocol configuration
failure)[Times]]+[HRPD
Session Released from AT
(Protocol negotiation error)
[Times]]+[HRPD Session
Released from AT(Session
configuration failure)[Times]]
+[HRPD Session Released
from AT(Others)[Times]])+
([HRPD Session Released
from AN(Source AN release in
inter AN handoff)[Times]]+
[HRPD Session Released from
AN(Release old session in
session setup)[Times]]+
[HRPD Session Released from
AN(Keep alive timer expired)
[Times]]+[HRPD Session
Released from AN(Authority
failed)[Times]]+[HRPD
Session Released from AN
(Configure failed)[Times]]+
[HRPD Session Released from
AN(Others)[Times]]+[HRPD
Session Released from AN
(MML operated)[Times]]))*
{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 474


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

HRPD Session % Performance [HRPD Session Released from


Released from AT Stat of BSC AT(Others)[Times]]/(([HRPD
(Others) Ratio HRPD Session Released from AT
Sessions (Normal closed)[Times]]+
[HRPD Session Released from
AT(Protocol error)[Times]]+
[HRPD Session Released from
AT(Protocol configuration
failure)[Times]]+[HRPD
Session Released from AT
(Protocol negotiation error)
[Times]]+[HRPD Session
Released from AT(Session
configuration failure)[Times]]
+[HRPD Session Released
from AT(Others)[Times]])+
([HRPD Session Released
from AN(Source AN release in
inter AN handoff)[Times]]+
[HRPD Session Released from
AN(Release old session in
session setup)[Times]]+
[HRPD Session Released from
AN(Keep alive timer expired)
[Times]]+[HRPD Session
Released from AN(Authority
failed)[Times]]+[HRPD
Session Released from AN
(Configure failed)[Times]]+
[HRPD Session Released from
AN(Others)[Times]]+[HRPD
Session Released from AN
(MML operated)[Times]]))*
{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 475


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

HRPD Session % Performance [HRPD Session Released from


Released from AN Stat of BSC AN(Authority failed)[Times]]/
(Authority failed) HRPD (([HRPD Session Released
Ratio Sessions from AT(Normal closed)
[Times]]+[HRPD Session
Released from AT(Protocol
error)[Times]]+[HRPD
Session Released from AT
(Protocol configuration failure)
[Times]]+[HRPD Session
Released from AT(Protocol
negotiation error)[Times]]+
[HRPD Session Released from
AT(Session configuration
failure)[Times]]+[HRPD
Session Released from AT
(Others)[Times]])+([HRPD
Session Released from AN
(Source AN release in inter AN
handoff)[Times]]+[HRPD
Session Released from AN
(Release old session in session
setup)[Times]]+[HRPD
Session Released from AN
(Keep alive timer expired)
[Times]]+[HRPD Session
Released from AN(Authority
failed)[Times]]+[HRPD
Session Released from AN
(Configure failed)[Times]]+
[HRPD Session Released from
AN(Others)[Times]]+[HRPD
Session Released from AN
(MML operated)[Times]]))*
{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 476


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

HRPD Session % Performance [HRPD Session Released from


Released from AT Stat of BSC AT(Protocol error)[Times]]/
(Protocol error) Ratio HRPD (([HRPD Session Released
Sessions from AT(Normal closed)
[Times]]+[HRPD Session
Released from AT(Protocol
error)[Times]]+[HRPD
Session Released from AT
(Protocol configuration failure)
[Times]]+[HRPD Session
Released from AT(Protocol
negotiation error)[Times]]+
[HRPD Session Released from
AT(Session configuration
failure)[Times]]+[HRPD
Session Released from AT
(Others)[Times]])+([HRPD
Session Released from AN
(Source AN release in inter AN
handoff)[Times]]+[HRPD
Session Released from AN
(Release old session in session
setup)[Times]]+[HRPD
Session Released from AN
(Keep alive timer expired)
[Times]]+[HRPD Session
Released from AN(Authority
failed)[Times]]+[HRPD
Session Released from AN
(Configure failed)[Times]]+
[HRPD Session Released from
AN(Others)[Times]]+[HRPD
Session Released from AN
(MML operated)[Times]]))*
{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 477


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

HRPD Session % Performance [HRPD Session Released from


Released from AN Stat of BSC AN(Source AN release in inter
(Source AN release HRPD AN handoff)[Times]]/
in inter AN handoff) Sessions (([HRPD Session Released
Ratio from AT(Normal closed)
[Times]]+[HRPD Session
Released from AT(Protocol
error)[Times]]+[HRPD
Session Released from AT
(Protocol configuration failure)
[Times]]+[HRPD Session
Released from AT(Protocol
negotiation error)[Times]]+
[HRPD Session Released from
AT(Session configuration
failure)[Times]]+[HRPD
Session Released from AT
(Others)[Times]])+([HRPD
Session Released from AN
(Source AN release in inter AN
handoff)[Times]]+[HRPD
Session Released from AN
(Release old session in session
setup)[Times]]+[HRPD
Session Released from AN
(Keep alive timer expired)
[Times]]+[HRPD Session
Released from AN(Authority
failed)[Times]]+[HRPD
Session Released from AN
(Configure failed)[Times]]+
[HRPD Session Released from
AN(Others)[Times]]+[HRPD
Session Released from AN
(MML operated)[Times]]))*
{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 478


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

HRPD Session % Performance [HRPD Session Released from


Released from AT Stat of BSC AT(Session configuration
(Session HRPD failure)[Times]]/(([HRPD
configuration failure) Sessions Session Released from AT
Ratio (Normal closed)[Times]]+
[HRPD Session Released from
AT(Protocol error)[Times]]+
[HRPD Session Released from
AT(Protocol configuration
failure)[Times]]+[HRPD
Session Released from AT
(Protocol negotiation error)
[Times]]+[HRPD Session
Released from AT(Session
configuration failure)[Times]]
+[HRPD Session Released
from AT(Others)[Times]])+
([HRPD Session Released
from AN(Source AN release in
inter AN handoff)[Times]]+
[HRPD Session Released from
AN(Release old session in
session setup)[Times]]+
[HRPD Session Released from
AN(Keep alive timer expired)
[Times]]+[HRPD Session
Released from AN(Authority
failed)[Times]]+[HRPD
Session Released from AN
(Configure failed)[Times]]+
[HRPD Session Released from
AN(Others)[Times]]+[HRPD
Session Released from AN
(MML operated)[Times]]))*
{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 479


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

HRPD Session % Performance [HRPD Session Released from


Released from AN Stat of BSC AN(MML operated)[Times]]/
(MML operated) HRPD (([HRPD Session Released
Ratio Sessions from AT(Normal closed)
[Times]]+[HRPD Session
Released from AT(Protocol
error)[Times]]+[HRPD
Session Released from AT
(Protocol configuration failure)
[Times]]+[HRPD Session
Released from AT(Protocol
negotiation error)[Times]]+
[HRPD Session Released from
AT(Session configuration
failure)[Times]]+[HRPD
Session Released from AT
(Others)[Times]])+([HRPD
Session Released from AN
(Source AN release in inter AN
handoff)[Times]]+[HRPD
Session Released from AN
(Release old session in session
setup)[Times]]+[HRPD
Session Released from AN
(Keep alive timer expired)
[Times]]+[HRPD Session
Released from AN(Authority
failed)[Times]]+[HRPD
Session Released from AN
(Configure failed)[Times]]+
[HRPD Session Released from
AN(Others)[Times]]+[HRPD
Session Released from AN
(MML operated)[Times]]))*
{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 480


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

HRPD Session % Performance [HRPD Session Released from


Released from AN Stat of BSC AN(Others)[Times]]/(([HRPD
(Others) Ratio HRPD Session Released from AT
Sessions (Normal closed)[Times]]+
[HRPD Session Released from
AT(Protocol error)[Times]]+
[HRPD Session Released from
AT(Protocol configuration
failure)[Times]]+[HRPD
Session Released from AT
(Protocol negotiation error)
[Times]]+[HRPD Session
Released from AT(Session
configuration failure)[Times]]
+[HRPD Session Released
from AT(Others)[Times]])+
([HRPD Session Released
from AN(Source AN release in
inter AN handoff)[Times]]+
[HRPD Session Released from
AN(Release old session in
session setup)[Times]]+
[HRPD Session Released from
AN(Keep alive timer expired)
[Times]]+[HRPD Session
Released from AN(Authority
failed)[Times]]+[HRPD
Session Released from AN
(Configure failed)[Times]]+
[HRPD Session Released from
AN(Others)[Times]]+[HRPD
Session Released from AN
(MML operated)[Times]]))*
{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 481


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

HRPD Session % Performance [HRPD Session Released from


Released from AN Stat of BSC AN(Configure failed)[Times]]/
(Configure failed) HRPD (([HRPD Session Released
Ratio Sessions from AT(Normal closed)
[Times]]+[HRPD Session
Released from AT(Protocol
error)[Times]]+[HRPD
Session Released from AT
(Protocol configuration failure)
[Times]]+[HRPD Session
Released from AT(Protocol
negotiation error)[Times]]+
[HRPD Session Released from
AT(Session configuration
failure)[Times]]+[HRPD
Session Released from AT
(Others)[Times]])+([HRPD
Session Released from AN
(Source AN release in inter AN
handoff)[Times]]+[HRPD
Session Released from AN
(Release old session in session
setup)[Times]]+[HRPD
Session Released from AN
(Keep alive timer expired)
[Times]]+[HRPD Session
Released from AN(Authority
failed)[Times]]+[HRPD
Session Released from AN
(Configure failed)[Times]]+
[HRPD Session Released from
AN(Others)[Times]]+[HRPD
Session Released from AN
(MML operated)[Times]]))*
{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 482


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

HRPD Session % Performance [HRPD Session Released from


Released from AT Stat of BSC AT(Protocol configuration
(Protocol HRPD failure)[Times]]/(([HRPD
configuration failure) Sessions Session Released from AT
Ratio (Normal closed)[Times]]+
[HRPD Session Released from
AT(Protocol error)[Times]]+
[HRPD Session Released from
AT(Protocol configuration
failure)[Times]]+[HRPD
Session Released from AT
(Protocol negotiation error)
[Times]]+[HRPD Session
Released from AT(Session
configuration failure)[Times]]
+[HRPD Session Released
from AT(Others)[Times]])+
([HRPD Session Released
from AN(Source AN release in
inter AN handoff)[Times]]+
[HRPD Session Released from
AN(Release old session in
session setup)[Times]]+
[HRPD Session Released from
AN(Keep alive timer expired)
[Times]]+[HRPD Session
Released from AN(Authority
failed)[Times]]+[HRPD
Session Released from AN
(Configure failed)[Times]]+
[HRPD Session Released from
AN(Others)[Times]]+[HRPD
Session Released from AN
(MML operated)[Times]]))*
{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 483


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

HRPD Session % Performance [HRPD Session Released from


Released from AN Stat of BSC AN(Release old session in
(Release old session HRPD session setup)[Times]]/
in session setup) Sessions (([HRPD Session Released
Ratio from AT(Normal closed)
[Times]]+[HRPD Session
Released from AT(Protocol
error)[Times]]+[HRPD
Session Released from AT
(Protocol configuration failure)
[Times]]+[HRPD Session
Released from AT(Protocol
negotiation error)[Times]]+
[HRPD Session Released from
AT(Session configuration
failure)[Times]]+[HRPD
Session Released from AT
(Others)[Times]])+([HRPD
Session Released from AN
(Source AN release in inter AN
handoff)[Times]]+[HRPD
Session Released from AN
(Release old session in session
setup)[Times]]+[HRPD
Session Released from AN
(Keep alive timer expired)
[Times]]+[HRPD Session
Released from AN(Authority
failed)[Times]]+[HRPD
Session Released from AN
(Configure failed)[Times]]+
[HRPD Session Released from
AN(Others)[Times]]+[HRPD
Session Released from AN
(MML operated)[Times]]))*
{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 484


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

HRPD Session % Performance [HRPD Session Released from


Released from AN Stat of BSC AN(Keep alive timer expired)
(Keep alive timer HRPD [Times]]/(([HRPD Session
expired) Ratio Sessions Released from AT(Normal
closed)[Times]]+[HRPD
Session Released from AT
(Protocol error)[Times]]+
[HRPD Session Released from
AT(Protocol configuration
failure)[Times]]+[HRPD
Session Released from AT
(Protocol negotiation error)
[Times]]+[HRPD Session
Released from AT(Session
configuration failure)[Times]]
+[HRPD Session Released
from AT(Others)[Times]])+
([HRPD Session Released
from AN(Source AN release in
inter AN handoff)[Times]]+
[HRPD Session Released from
AN(Release old session in
session setup)[Times]]+
[HRPD Session Released from
AN(Keep alive timer expired)
[Times]]+[HRPD Session
Released from AN(Authority
failed)[Times]]+[HRPD
Session Released from AN
(Configure failed)[Times]]+
[HRPD Session Released from
AN(Others)[Times]]+[HRPD
Session Released from AN
(MML operated)[Times]]))*
{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 485


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Access Authentication Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Access Access times Performance -


Authenti Authentication Stat of BSC
cation Attempts[Times] HRPD
Success Sessions
Ratio
Access % Performance ([Successful Access
Authentication Stat of BSC Authentications[Times]]/
Success Ratio[%] HRPD [Access Authentication
Sessions Attempts[Times]])*{100}

Access Access % Performance [Access Authentication


Authenti Authentication Stat of BSC Rejections[Times]]/[Access
cation Rejections Ratio HRPD Authentications Failure
Failure Sessions [Times]]*{100}

Access % Performance [Access Authentication LCP


Authentication LCP Stat of BSC Negotiation Failure[Times]]/
Negotiation Failure HRPD [Access Authentications
Ratio Sessions Failure[Times]]*{100}

Called Number/Call % Performance [Access Authentication No


Number Stat of BSC Resource[Times]]/[Access
HRPD Authentications Failure
Sessions [Times]]*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 486


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Access % Performance ([Access Authentication No


Authentication Stat of BSC Resource[Times]]-[Access
Rejections(Other HRPD Authentication Rejections
causes) Ratio Sessions [Times]]-[Access
Authentication LCP
Negotiation Failure[Times]]-
[Access Authentication No
Resource[Times]])/[Access
Authentications Failure
[Times]]*{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

8.3.4 Accessablity Report

Connection Setup Success Ratio Trend Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 487


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

BSC Connection Requests times Performance -


Quick [Times] Stat of BSC
Connecti EV-DO
on Setup Connection
Success Setup
Ratio
Connection Success % Performance ([Successful Connection Times
Ratio[%] Stat of BSC [Times]]/[Connection
EV-DO Requests[Times]])*{100}
Connection
Setup

Quick Quick Connection times Performance -


BSC Requests[Times] Stat of BSC
Connecti EV-DO
on Setup Connection
Success Setup
Ratio
Quick Connection % Performance ([Successful Quick Connection
Success Ratio[%] Stat of BSC Times[Times]]/[Quick
EV-DO Connection Requests[Times]])
Connection *{100}
Setup

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Connection Setup Failure Reason Report

Report Type
Simple Report

NE Type
CBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 488


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Connecti AN-Initiated times Performance -


on Setup Connection Failures Stat of BSC
Failure (No R-TCH EV-DO
Reason Detected)[Times] Connection
Setup

AN-Initiated times Performance -


Connection Failures Stat of BSC
(Call resources EV-DO
allocation failure) Connection
[Times] Setup

AN-Initiated times Performance -


Connection Failures Stat of BSC
(No Traffic Channel EV-DO
Complete received) Connection
[Times] Setup

AN-Initiated times Performance -


Connection Failures Stat of BSC
(Other causes) EV-DO
[Times] Connection
Setup

Quick Connection times Performance -


Failures (No R-TCH Stat of BSC
detected)[Times] EV-DO
Connection
Setup

Quick Connection times Performance -


Failures (Call Stat of BSC
resources allocation EV-DO
failure)[Times] Connection
Setup

Quick Connection times Performance -


Failures (No Traffic Stat of BSC
Channel Complete EV-DO
received)[Times] Connection
Setup

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 489


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Quick Connection times Performance -


Failures (Other Stat of BSC
causes)[Times] EV-DO
Connection
Setup

Carrier Connection Success % Performance ([Successful Connection Times


with The Ratio[%] Stat of [Times]]/[Connection
Worst Carrier EV- Requests[Times]])*{100}
Connecti DO
on Setup Connection
Success Setup

Connection Requests times Performance -


[Times] Stat of
Carrier EV-
DO
Connection
Setup

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Connection Setup Duration Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 490


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Called Connection Requests times Performance -


Number [Times] Stat of BSC
in EV-DO
Proportio Connection
n to Call Setup
Number
Connection Setup ms Performance [Connection Requests[Times]]
Duration Stat of BSC *[Connection Setup Average
EV-DO Duration[Millisecond]]/
Connection [Successful Connection Times
Setup [Times]]

The Connection Setup ms Performance -


Carrier Average Duration Stat of
Order by [Millisecond] Carrier EV-
Connecti DO
on Setup Connection
Duration Setup

Connection Requests times Performance -


[Times] Stat of
Carrier EV-
DO
Connection
Setup

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Paging Success Ratio Report

Report Type
Simple Report

NE Type
CBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 491


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

BSC EV-DO Paging times Performance -


Paging Attempts[Times] Stat of BSC
Success HRPD
Ratio Sessions

EV-DO Paging % Performance [Successful EV-DO Paging


Success Ratio[%] Stat of BSC Times[Times]]/[EV-DO
HRPD Paging Attempts[Times]]*
Sessions {100}

Called Called Number/Call % Performance [Access Authentication No


Number Number Stat of BSC Resource[Times]]/[Access
in HRPD Authentications Failure
Proportio Sessions [Times]]*{100}
n to Call
Number

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

8.3.5 Network Cover Report

RSSI Analysis Report

Report Type
Simple Report

NE Type
CBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 492


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Object Type
CBTS

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Carrier Main RSSI Average none RSSI -


order by Value[0.1dBm] Performance
Main Stat
RSSI
Desc Div RSSI Average none RSSI -
Value[0.1dBm] Performance
Stat

Carrier Div RSSI Average none RSSI -


order by Value[0.1dBm] Performance
Div RSSI Stat
Desc
Main RSSI Average none RSSI -
Value[0.1dBm] Performance
Stat

Carrier Difference Between none RSSI [Main RSSI Average Value


order by Main And Diversity Performance [0.1dBm]]-[Div RSSI Average
Differenc RSSI Average Value Stat Value[0.1dBm]]
e
between Div RSSI Average none RSSI -
Main Value[0.1dBm] Performance
RSSI and Stat
Div RSSI Main RSSI Average none RSSI -
Value[0.1dBm] Performance
Stat

Carrier Main RSSI Average none RSSI -


order by Value[0.1dBm] Performance
Main Stat
RSSI Asc
Div RSSI Average none RSSI -
Value[0.1dBm] Performance
Stat

Carrier Div RSSI Average none RSSI -


order by Value[0.1dBm] Performance
Div RSSI Stat
Asc
Main RSSI Average none RSSI -
Value[0.1dBm] Performance
Stat

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 493


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Access Pilot Strength Analysis Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Distributi Access Times by % EV-DO BSC [Access Times by Access Pilot


on of Access Pilot Strength Cover Strength(0,2)[Times]]/
Intra- (-0,-2) Ratio Performance ([Access Times by Access Pilot
BSC AT Stat of Strength(-10.5,-31.5)[Times]]
Access Access State +[Access Times by Access
Pilot Pilot Strength(-2.5,-4.5)
Strength [Times]]+[Access Times by
Access Pilot Strength(-5,-7)
[Times]]+[Access Times by
Access Pilot Strength(-7.5,-10)
[Times]]+[Access Times by
Access Pilot Strength(0,2)
[Times]])*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 494


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Access Times by % EV-DO BSC [Access Times by Access Pilot


Access Pilot Strength Cover Strength(-10.5,-31.5)[Times]]/
(-10.5,-31.5) Ratio Performance ([Access Times by Access Pilot
Stat of Strength(-10.5,-31.5)[Times]]
Access State +[Access Times by Access
Pilot Strength(-2.5,-4.5)
[Times]]+[Access Times by
Access Pilot Strength(-5,-7)
[Times]]+[Access Times by
Access Pilot Strength(-7.5,-10)
[Times]]+[Access Times by
Access Pilot Strength(0,2)
[Times]])*{100}

Access Times by % EV-DO BSC [Access Times by Access Pilot


Access Pilot Strength Cover Strength(-2.5,-4.5)[Times]]/
(-2.5,-4.5) Ratio Performance ([Access Times by Access Pilot
Stat of Strength(-10.5,-31.5)[Times]]
Access State +[Access Times by Access
Pilot Strength(-2.5,-4.5)
[Times]]+[Access Times by
Access Pilot Strength(-5,-7)
[Times]]+[Access Times by
Access Pilot Strength(-7.5,-10)
[Times]]+[Access Times by
Access Pilot Strength(0,2)
[Times]])*{100}

Access Times by % EV-DO BSC [Access Times by Access Pilot


Access Pilot Strength Cover Strength(-5,-7)[Times]]/
(-5,-7) Ratio Performance ([Access Times by Access Pilot
Stat of Strength(-10.5,-31.5)[Times]]
Access State +[Access Times by Access
Pilot Strength(-2.5,-4.5)
[Times]]+[Access Times by
Access Pilot Strength(-5,-7)
[Times]]+[Access Times by
Access Pilot Strength(-7.5,-10)
[Times]]+[Access Times by
Access Pilot Strength(0,2)
[Times]])*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 495


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Access Times by % EV-DO BSC [Access Times by Access Pilot


Access Pilot Strength Cover Strength(-7.5,-10)[Times]]/
(-7.5,-10) Ratio Performance ([Access Times by Access Pilot
Stat of Strength(-10.5,-31.5)[Times]]
Access State +[Access Times by Access
Pilot Strength(-2.5,-4.5)
[Times]]+[Access Times by
Access Pilot Strength(-5,-7)
[Times]]+[Access Times by
Access Pilot Strength(-7.5,-10)
[Times]]+[Access Times by
Access Pilot Strength(0,2)
[Times]])*{100}

Access Times by times EV-DO -


Access Pilot Strength Carrier
(-10.5,-31.5)[Times] Cover
Performance
Stat of
Access State

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Soft HO Ratio Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 496


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

BSC Soft Soft HO Ratio % EV-DO BSC ([DO 0 Traffic Channel CE


HO Ratio Traffic Total time(DO 0) [Second]]+
Performance [DO A Traffic Channel CE
Stat Total time(DO A) [Second]]-
[DO 0 Traffic Channel
Connection Total time(DO 0)
[Second]]-[DO A Traffic
Channel Connection Total time
(DO A) [Second]])/([DO 0
Traffic Channel CE Total time
(DO 0) [Second]]+[DO A
Traffic Channel CE Total time
(DO A) [Second]])*{100}

Carrier Soft HO Ratio % EV-DO ([DO 0 Traffic Channel CE


order by Carrier Total time(DO 0) [Second]]+
Soft HO Traffic [DO A Traffic Channel CE
Ratio Performance Total time(DO A) [Second]]-
Stat [DO A Traffic Channel
Connection Total time(DO A)
[Second]]-[DO 0 Traffic
Channel Connection Total time
(DO 0) [Second]])/([DO 0
Traffic Channel CE Total time
(DO 0) [Second]]+[DO A
Traffic Channel CE Total time
(DO A) [Second]])*{100}

DO Traffic Channel s EV-DO [DO 0 Traffic Channel


Seizure Total time Carrier Connection Total time(DO 0)
Traffic [Second]]+[DO A Traffic
Performance Channel Connection Total time
Stat (DO A) [Second]]

CE Total time s EV-DO [DO 0 Traffic Channel CE


Carrier Total time(DO 0) [Second]]+
Traffic [DO A Traffic Channel CE
Performance Total time(DO A) [Second]]
Stat

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 497


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Carrier Soft HO Ratio % EV-DO ([DO 0 Traffic Channel CE


order by Carrier Total time(DO 0) [Second]]+
Soft HO Traffic [DO A Traffic Channel CE
Ratio Performance Total time(DO A) [Second]]-
Asc Stat [DO A Traffic Channel
Connection Total time(DO A)
[Second]]-[DO 0 Traffic
Channel Connection Total time
(DO 0) [Second]])/([DO 0
Traffic Channel CE Total time
(DO 0) [Second]]+[DO A
Traffic Channel CE Total time
(DO A) [Second]])*{100}

DO Traffic Channel s EV-DO [DO 0 Traffic Channel


Seizure Total time Carrier Connection Total time(DO 0)
Traffic [Second]]+[DO A Traffic
Performance Channel Connection Total time
Stat (DO A) [Second]]

CE Total time s EV-DO [DO 0 Traffic Channel CE


Carrier Total time(DO 0) [Second]]+
Traffic [DO A Traffic Channel CE
Performance Total time(DO A) [Second]]
Stat

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

8.3.6 Network Capability Report

Carrier Order of CBTS Forward Throughput Report

Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 498


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NE Type
CBSC

Object Type
CBTS

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Carrier DO FTCH Forward none DO TCH -


order by RLP Layer Transmit Forward RLP
Forward Throughput[byte] Throughput
Through Stat
put Desc
DO FTCH Forward none DO TCH -
RLP Layer Forward RLP
Retransmit Throughput
Throughput[byte] Stat

Carrier DO FTCH Forward none DO TCH -


order by RLP Layer Transmit Forward RLP
Forward Throughput[byte] Throughput
Through Stat
put Asc
DO FTCH Forward none DO TCH -
RLP Layer Forward RLP
Retransmit Throughput
Throughput[byte] Stat

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Traffic Report

Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 499


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NE Type
CBSC

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Traffic DO Traffic Channel Erl EV-DO BSC ([DO 0 Traffic Channel


Trend Connection Strength Traffic Connection Total time(DO 0)
Performance [Second]]+[DO A Traffic
Stat Channel Connection Total time
(DO A) [Second]])/{GP}

DO Traffic Channel Erl EV-DO BSC ([DO 0 Traffic Channel CE


CE Strength Traffic Total time(DO 0) [Second]]+
Performance [DO A Traffic Channel CE
Stat Total time(DO A) [Second]])/
{GP}

DO Traffic Channel Erl EV-DO BSC ([DO 0 Traffic Channel


MacIndex Strength Traffic MacIndex Total time(DO 0)
Performance [Second]]+[DO A Traffic
Stat Channel MacIndex Total time
(DO A) [Second]])/{GP}

Carrier DO Traffic Channel Erl EV-DO ([DO 0 Traffic Channel


Order by Connection Strength Carrier Connection Total time(DO 0)
TCH Traffic [Second]]+[DO A Traffic
Traffic Performance Channel Connection Total time
Desc Stat (DO A) [Second]])/{GP}

DO Traffic Channel s EV-DO [DO 0 Traffic Channel


Connection Total Carrier Connection Total time(DO 0)
time Traffic [Second]]+[DO A Traffic
Performance Channel Connection Total time
Stat (DO A) [Second]]

DO Traffic Channel Erl EV-DO ([DO A Traffic Channel CE


CE Strength Carrier Total time(DO A) [Second]]+
Traffic [DO 0 Traffic Channel CE
Performance Total time(DO 0) [Second]])/
Stat {GP}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 500


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

DO Traffic Channel Erl EV-DO ([DO 0 Traffic Channel


MacIndex Strength Carrier MacIndex Total time(DO 0)
Traffic [Second]]+[DO A Traffic
Performance Channel MacIndex Total time
Stat (DO A) [Second]])/{GP}

Max Active numb Performance -


Connectors of er Stat of
Carrier[Entries] Carrier EV-
DO
Connection
Release

Carrier DO Traffic Channel Erl EV-DO ([DO 0 Traffic Channel


Order by Connection Strength Carrier Connection Total time(DO 0)
TCH Traffic [Second]]+[DO A Traffic
Traffic Performance Channel Connection Total time
Asc Stat (DO A) [Second]])/{GP}

DO Traffic Channel s EV-DO [DO 0 Traffic Channel


Connection Total Carrier Connection Total time(DO 0)
time Traffic [Second]]+[DO A Traffic
Performance Channel Connection Total time
Stat (DO A) [Second]]

DO Traffic Channel Erl EV-DO ([DO A Traffic Channel CE


CE Strength Carrier Total time(DO A) [Second]]+
Traffic [DO 0 Traffic Channel CE
Performance Total time(DO 0) [Second]])/
Stat {GP}

DO Traffic Channel Erl EV-DO ([DO 0 Traffic Channel


MacIndex Strength Carrier MacIndex Total time(DO 0)
Traffic [Second]]+[DO A Traffic
Performance Channel MacIndex Total time
Stat (DO A) [Second]])/{GP}

Max Active numb Performance -


Connectors of er Stat of
Carrier[Entries] Carrier EV-
DO
Connection
Release

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 501


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Traffic Channel Load Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBTS

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Carrier DO CCH Average % DO CCH [DO CCH Average


Order by Packet Occupancy Using Ratio Synchronous Packet
EVDO Performance Occupancy Ratio[%]]+[DO
CCH Stat CCH Average Asynchronous
Load Packet Occupancy Ratio[%]]+
Desc [DO CCH Average Sub-
Synchronous Packet
Occupancy Ratio[%]]

DO CCH Average none DO CCH -


Synchronous Packet Using Ratio
Occupancy Ratio[%] Performance
Stat

DO CCH Average none DO CCH -


Asynchronous Using Ratio
Packet Occupancy Performance
Ratio[%] Stat

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 502


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

DO CCH Average none DO CCH -


Sub-Synchronous Using Ratio
Packet Occupancy Performance
Ratio[%] Stat

DO CCH Discarded none DO CCH -


Sync Message Ratio Discard
[%] Performance
Stat

DO CCH Discarded none DO CCH -


Asynchronous Discard
Message Ratio[%] Performance
Stat

Carrier ACH Average Using none ACH -


Order by Ratio[%] Performance
ACH Stat
Channel
Load ACH Max Using none ACH -
Desc Ratio[%] Performance
Stat

ACH Min Using none ACH -


Ratio[%] Performance
Stat

ACH Average none ACH -


Collision Ratio[%] Performance
Stat

ACH Max Collision none ACH -


Ratio[%] Performance
Stat

ACH Min Collision none ACH -


Ratio[%] Performance
Stat

Carrier DO TCH Average none DO TCH -


Order by ROT[1/8db] Load
TCH Performance
Reverse Stat
Load
Desc DO TCH Maximum none DO TCH -
ROT[1/8db] Load
Performance
Stat

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 503


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

DO TCH Minimum none DO TCH -


ROT[1/8db] Load
Performance
Stat

DO TCH Reverse none DO TCH -


Load[1/8db] Load
Performance
Stat

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Service Data Throughput Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

BSC Forward Octets kiloby RLP -


Forward Between PCF and tes Throughput
and BSC[KB] Stat
Reverse
RLP

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 504


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Layer RLP Octets Received kiloby RLP -


Through on Reverse Channels tes Throughput
put Trend [KB] Stat

Carrier RLP Octets Received kiloby Do Carrier -


Order by on Reverse Channels tes Performance
Reverse [KB] Mesurement
Through
put Asc Reverse repeat RLP byte Do Carrier -
Octets[Byte] Performance
Mesurement

Octets Resent on byte Do Carrier -


request of AN[Byte] Performance
Mesurement

RLP Octets Not kiloby Do Carrier -


Received on Reverse tes Performance
Channels[KB] Mesurement

Reverse Abort times Do Carrier -


[Times] Performance
Mesurement

Carrier RLP Octets Received kiloby Do Carrier -


Order by on Reverse Channels tes Performance
Reverse [KB] Mesurement
Through
put Desc Reverse repeat RLP byte Do Carrier -
Octets[Byte] Performance
Mesurement

Octets Resent on byte Do Carrier -


request of AN[Byte] Performance
Mesurement

RLP Octets Not kiloby Do Carrier -


Received on Reverse tes Performance
Channels[KB] Mesurement

Reverse Abort times Do Carrier -


[Times] Performance
Mesurement

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 505


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

8.3.7 Mobility Report

Inter-AN Hard HO Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

EVDO Successful Inter-AN % Performance [Successful Inter-AN


Inter-AN Incoming Hard HOs Stat of Inter- Incoming Hard HOs[Times]]/
Incoming Ratio AN Hard HO [Inter-AN Incoming Hard HO
Hard HO Requests[Times]]*{100}
and Hard
HO Successful Inter-AN % Performance [Successful Inter-AN Hard
Success Hard HOs Ratio Stat of Inter- HOs[Times]]/[Inter-AN Hard
Ratio AN Hard HO HO Requests[Times]]*{100}
Trend

Inter-AN Inter-AN Hard HO % Performance [Inter-AN Hard HO Failures


Hard HO Failures (Radio Stat of Inter- (Radio resources unavailable)
Failure resources AN Hard HO [Times]]/([Inter-AN Hard HO
unavailable) Ratio Requests[Times]]-[Successful
Inter-AN Hard HOs[Times]])*
{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 506


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Inter-AN Hard HO % Performance [Inter-AN Hard HO Failures


Failures (Requested Stat of Inter- (Requested terrestrial
terrestrial resources AN Hard HO resources unavailable)
unavailable) Ratio [Times]]/([Inter-AN Hard HO
Requests[Times]]-[Successful
Inter-AN Hard HOs[Times]])*
{100}

Inter-AN Hard HO % Performance [Inter-AN Hard HO Failures


Failures (MS Not Stat of Inter- (MS Not detected by
detected by AN Hard HO destination pilot)[Times]]/
destination pilot) ([Inter-AN Hard HO Requests
Ratio [Times]]-[Successful Inter-AN
Hard HOs[Times]])*{100}

Inter-AN Hard HO % Performance [Inter-AN Hard HO Failures


Failures (Other Stat of Inter- (Other causes)[Times]]/([Inter-
causes) Ratio AN Hard HO AN Hard HO Requests
[Times]]-[Successful Inter-AN
Hard HOs[Times]])*{100}

Inter-AN Inter-AN Incoming % Performance [Inter-AN Incoming Hard HOs


Incoming Hard HOs Failures Stat of Inter- Failures (Resource Allocation
Hard HO (Resource Allocation AN Hard HO Failed)[Times]]/([Inter-AN
Failure Failed) Ratio Incoming Hard HO Requests
[Times]]-[Successful Inter-AN
Incoming Hard HOs[Times]])*
{100}

Inter-AN Incoming % Performance [Inter-AN Incoming Hard HOs


Hard HOs Failures Stat of Inter- Failures (HO Execution Failed)
(HO Execution AN Hard HO [Times]]/([Inter-AN Incoming
Failed) Ratio Hard HO Requests[Times]]-
[Successful Inter-AN
Incoming Hard HOs[Times]])*
{100}

Inter-AN Incoming % Performance [Inter-AN Incoming Hard HOs


Hard HOs Failures Stat of Inter- Failures (Other causes)
(Other causes) Ratio AN Hard HO [Times]]/([Inter-AN Incoming
Hard HO Requests[Times]]-
[Successful Inter-AN
Incoming Hard HOs[Times]])*
{100}

Carrier Inter-AN Incoming times Performance -


Order by Hard HO Requests Stat of
Inter-AN [Times] Carrier Inter-
AN Hard HO

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 507


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Incoming Successful Inter-AN % Performance [Successful Inter-AN


Hard HO Incoming Hard HOs Stat of Incoming Hard HOs[Times]]/
Ratio Carrier Inter- [Inter-AN Incoming Hard HO
AN Hard HO Requests[Times]]*{100}

Inter-AN Incoming times Performance -


Hard HOs Failures Stat of
(Resource Allocation Carrier Inter-
Failed)[Times] AN Hard HO

Inter-AN Incoming times Performance -


Hard HOs Failures Stat of
(HO Execution Carrier Inter-
Failed)[Times] AN Hard HO

Inter-AN Incoming times Performance -


Hard HOs Failures Stat of
(Other causes) Carrier Inter-
[Times] AN Hard HO

Carrier Inter-AN Hard HO times Performance -


Order by Requests[Times] Stat of
Inter-AN Carrier Inter-
Hard HO AN Hard HO

Successful Inter-AN % Performance [Successful Inter-AN Hard


Hard HOs Ratio Stat of HOs[Times]]/[Inter-AN Hard
Carrier Inter- HO Requests[Times]]*{100}
AN Hard HO

Inter-AN Hard HO times Performance -


Failures (Radio Stat of
resources Carrier Inter-
unavailable)[Times] AN Hard HO

Inter-AN Hard HO times Performance -


Failures (Requested Stat of
terrestrial resources Carrier Inter-
unavailable)[Times] AN Hard HO

Inter-AN Hard HO times Performance -


Failures (MS Not Stat of
detected by Carrier Inter-
destination pilot) AN Hard HO
[Times]

Inter-AN Hard HO times Performance -


Failures (Other Stat of
causes)[Times] Carrier Inter-
AN Hard HO

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 508


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Intra-AN Hard HO Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Intra-AN Intra-AN Hard HO times Performance -


Hard HO Requests[Times] Stat of Intra-
and AN Hard HO
Success
Ratio Intra-AN Hard HO % Performance ([Successful Intra-AN Hard
Trend Success Ratio[%] Stat of Intra- HOs[Times]]/[Intra-AN Hard
AN Hard HO HO Requests[Times]])*{100}

Intra-AN Intra-AN Hard HO % Performance [Intra-AN Hard HO Failures


Hard HO Failures (MS Not Stat of Intra- (MS Not detected by
Failure detected by AN Hard HO destination pilot)[Times]]/
Reason destination pilot) ([Intra-AN Hard HO Requests
Ratio [Times]]-[Successful Intra-AN
Hard HOs[Times]])*{100}

Intra-AN Hard HO % Performance [Intra-AN Hard HO Failures


Failures (Other Stat of Intra- (Other causes)[Times]]/([Intra-
causes) Ratio AN Hard HO AN Hard HO Requests
[Times]]-[Successful Intra-AN
Hard HOs[Times]])*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 509


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Intra-AN Hard HO % Performance [Intra-AN Hard HO Failures


Failures (Radio Stat of Intra- (Radio resources unavailable)
resources AN Hard HO [Times]]/([Intra-AN Hard HO
unavailable) Ratio Requests[Times]]-[Successful
Intra-AN Hard HOs[Times]])*
{100}

Intra-AN Hard HO % Performance [Intra-AN Hard HO Failures


Failures (Requested Stat of Intra- (Requested terrestrial
terrestrial resources AN Hard HO resources unavailable)
unavailable) Ratio [Times]]/([Intra-AN Hard HO
Requests[Times]]-[Successful
Intra-AN Hard HOs[Times]])*
{100}

Carrier Intra-AN Hard HO times Performance -


whth the Requests[Times] Stat of
Worst Carrier Intra-
Intra-AN AN Hard HO
Hard HO
Intra-AN Hard HO % Performance ([Successful Intra-AN Hard
Success Ratio[%] Stat of HOs[Times]]/[Intra-AN Hard
Carrier Intra- HO Requests[Times]])*{100}
AN Hard HO

Intra-AN Hard HO times Performance -


Failures (Radio Stat of
resources Carrier Intra-
unavailable)[Times] AN Hard HO

Intra-AN Hard HO times Performance -


Failures (Requested Stat of
terrestrial resources Carrier Intra-
unavailable)[Times] AN Hard HO

Intra-AN Hard HO times Performance -


Failures (MS Not Stat of
detected by Carrier Intra-
destination pilot) AN Hard HO
[Times]

Intra-AN Hard HO times Performance -


Failures (Other Stat of
causes)[Times] Carrier Intra-
AN Hard HO

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 510


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Inter-BS Soft Handoff Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Inter-BS Inter-BS Soft HO times Performance -


SHO Failures (Radio Stat of BSC
Success resources EV-DO
Ratio unavailable) EV-DO Reverse
[Times] Channel Soft
HO

Inter-BS Soft HO times Performance -


Failures (Requested Stat of BSC
Abis resources EV-DO
unavailable) EV-DO Reverse
[Times] Channel Soft
HO

Inter-BS Soft HO times Performance -


Failures (Radio Stat of BSC
interface abnormal) EV-DO
EV-DO[Times] Reverse
Channel Soft
HO

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 511


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Inter-BS Soft HO times Performance -


Failures (MS Stat of BSC
rejected) EV-DO EV-DO
[Times] Reverse
Channel Soft
HO

Inter-BS Soft HO times Performance -


Failures (A17/A18 Stat of BSC
link setup failed) EV- EV-DO
DO[Times] Reverse
Channel Soft
HO

Inter-BS Soft HO times Performance -


Failures (Other Stat of BSC
causes) EV-DO EV-DO
[Times] Reverse
Channel Soft
HO

Inter-BS Inter-BS Soft HO times Performance [Inter-BS Soft HO requests-


SHO Requests Times Stat of BSC Add Leg EV-DO[Times]]+
Failures [Times] EV-DO [Inter-BS Soft HO requests-
Causes Reverse Del Leg EV-DO[Times]]
Channel Soft
HO

InterBS Soft HO % Performance (([Successful Inter-BS Soft


Success Ratio[%] Stat of BSC Hos-Add Leg EV-DO[Times]]
EV-DO +[Successful Inter-BS Soft
Reverse Hos-Del Leg EV-DO
Channel Soft [Times]])/([Inter-BS Soft HO
HO requests-Add Leg EV-DO
[Times]]+[Inter-BS Soft HO
requests-Del Leg EV-DO
[Times]]))*{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 512


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

IntraBS Soft HO Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Intra-BS Intra-BS Soft HO times Intra-BSC -


Soft HO Requests[Times] Soft HO
requests Performance
and Stat
Success
Ratio Intra-BS Soft HO % Intra-BSC [Successful Intra-BS Soft Hos
Trend Success Ratio[%] Soft HO [Times]]/[Intra-BS Soft HO
Performance Requests[Times]]*{100}
Stat

Distributi Intra-BS Soft HO % Intra-BSC [Intra-BS Soft HO Failures


on of Failures (Other Soft HO (Other causes)[Times]]/([Intra-
Intra-BS causes) Ratio Performance BS Soft HO Requests[Times]]-
Soft HO Stat [Successful Intra-BS Soft Hos
Failure [Times]])*{100}

Inter-BS Soft HO % Intra-BSC [Inter-BS Soft HO Failures


Failures (Radio Soft HO (Radio resources unavailable)
resources Performance [Times]]/([Intra-BS Soft HO
unavailable) Ratio Stat Requests[Times]]-[Successful
Intra-BS Soft Hos[Times]])*
{100}

Intra-BS Soft HO % Intra-BSC [Intra-BS Soft HO Failures


Failures (Radio Soft HO (Radio interface abnormal)
interface abnormal) Performance [Times]]/([Intra-BS Soft HO
Ratio Stat Requests[Times]]-[Successful
Intra-BS Soft Hos[Times]])*
{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 513


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Intra-BS Soft HO % Intra-BSC [Intra-BS Soft HO Failures


Failures (Requested Soft HO (Requested Abis resources
Abis resources Performance unavailable)[Times]]/([Intra-
unavailable) Ratio Stat BS Soft HO Requests[Times]]-
[Successful Intra-BS Soft Hos
[Times]])*{100}

Carrier Intra-BS Soft HO times Performance -


Order by requests EV-DO Stat of
Intra-BS [Times] Carrier EV-
Soft HO DO Reverse
Success Channel Soft
Ratio HO

Intra-BS Soft HO % Performance ([Successful Intra-BS Soft HO


Success Ratio[%] Stat of EV-DO[Times]]/[Intra-BS
Carrier EV- Soft HO requests EV-DO
DO Reverse [Times]])*{100}
Channel Soft
HO

Intra-BS Soft HO times Performance -


Failures (Radio Stat of
resources Carrier EV-
unavailable) EV-DO DO Reverse
[Times] Channel Soft
HO

Intra-BS Soft HO times Performance -


Failures (Requested Stat of
Abis resources Carrier EV-
unavailable)[Times] DO Reverse
Channel Soft
HO

Intra-BS Soft HO times Performance -


Failures (Radio Stat of
interface abnormal) Carrier EV-
[Times] DO Reverse
Channel Soft
HO

Intra-BS Soft HO times Performance -


Failures (Other Stat of
causes)[Times] Carrier EV-
DO Reverse
Channel Soft
HO

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 514


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

HRPD Session Transfer and Location Update Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

HRPD Inter-AN inter - none Performance [Successful Inter-subnet HOs


Session subnet HO Success Stat of BSC between ANs[Times]]/[Inter-
Transfer Ratio[%] HRPD subnet HO (between ANs)
and Sessions Attempts[Times]]*{100}
Location
Update A13 Session % Performance ([Successful A13 Session
Information Query Stat of BSC Information Queries[Times]]/
Success Ratio[%] HRPD [A13 Session Information
Sessions Query Attempts[Times]])*
{100}

Location Update % Performance ([Location Update Assignment


Assignment Success Stat of BSC (Location Assignment Sent)
Ratio HRPD [Times]]-[Location Update
Sessions Uncompletion(No Location
Complete Received)[Times]])/
[Location Update Attempts
(Location Notification
Received)[Times]]*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 515


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

8.3.8 Resource Usage Ratio Report

CBTS3606 DO CE Resource Usage Ratio Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBTS

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

DO DO Min Reverse CEs % BTS3606 [DO Min Reverse CEs


Reverse Occupied By Service DO Channel Occupied By Traffic Channels
Resource Channels Ratio Element [entries]]/[DO Max Available
Usage Performance Reverse CEs[entries]]*{100}
Ratio Stat
Sort
DO Max Reverse % BTS3606 [DO Max Reverse CEs
CEs Occupied By DO Channel Occupied By Traffic Channels
Service Channels Element [entries]]/[DO Max Available
Ratio Performance Reverse CEs[entries]]*{100}
Stat

DO Max Available none BTS3606 -


Reverse CEs[entries] DO Channel
Element
Performance
Stat

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 516


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

DO Min Available none BTS3606 -


Reverse CEs[entries] DO Channel
Element
Performance
Stat

DO Max Reverse none BTS3606 -


CEs Occupied By DO Channel
Traffic Channels Element
[entries] Performance
Stat

DO Min Reverse CEs none BTS3606 -


Occupied By Traffic DO Channel
Channels[entries] Element
Performance
Stat

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

CBTS3612 DO CE Resource Usage Ratio Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBTS

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 517


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

DO CE DO Min Reverse CEs % BTS3612 [DO Min Reverse CEs


Reverse Occupied By Service DO Channel Occupied By Service Channels
Resource Channels Ratio Element [entries]]/[DO Max Available
Usage Performance Reverse CEs[entries]]*{100}
Ratio Stat
Sort
DO Max Reverse % BTS3612 [DO Max Reverse CEs
CEs Occupied By DO Channel Occupied By Service Channels
Service Channels Element [entries]]/[DO Max Available
Ratio Performance Reverse CEs[entries]]*{100}
Stat

DO Min Available none BTS3612 -


Reverse CEs[entries] DO Channel
Element
Performance
Stat

DO Max Available none BTS3612 -


Reverse CEs[entries] DO Channel
Element
Performance
Stat

DO Min Reverse CEs none BTS3612 -


Occupied By Service DO Channel
Channels[entries] Element
Performance
Stat

DO Max Reverse none BTS3612 -


CEs Occupied By DO Channel
Service Channels Element
[entries] Performance
Stat

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 518


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

8.3.9 Cover Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

HRPD HRPD Session Setup % Performance ([Successful HRPD Session


Session Success Ratio[%] Stat of BSC setup[Times]]/[HRPD Session
Performa HRPD setup Requests[Times]])*
nce Sessions {100}

Maximum HRPD numb Performance -


Sessions[Entries] er Stat of BSC
HRPD
Sessions

Maximum number of numb Performance -


active HRPD er Stat of BSC
Sessions[Entries] HRPD
Sessions

Accessab Connection Success % Performance ([Successful Connection Times


lity Ratio[%] Stat of BSC [Times]]/[Connection
EV-DO Requests[Times]])*{100}
Connection
Setup

EV-DO Paging % Performance [Successful EV-DO Paging


Success Ratio[%] Stat of BSC Times[Times]]/[EV-DO
HRPD Paging Attempts[Times]]*
Sessions {100}

Call Connection Drop % Performance -


Retainabi Ratio[%] Stat of BSC
lity EV-DO
Connection
Release

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 519


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Traffic Drop Ratio none Performance ([DO 0 Traffic Channel


[Minute] Stat of BSC Connection Total time(DO 0)
EV-DO [Second]]+[DO A Traffic
Connection Channel Connection Total time
Release (DO A) [Second]])/
(([Connection Released (RF
lost)[Times]]+[Connection
Release (HHO Fail)[Times]]+
[Connection Released (Other
causes)[Times]])*{GP})

Mobility Intra-BS Soft HO % Intra-BSC [Successful Intra-BS Soft Hos


Success Ratio[%] Soft HO [Times]]/[Intra-BS Soft HO
Performance Requests[Times]]*{100}
Stat

Service Forward Link Data % RLP {100}*([Octets Resent on


Integrity Retransmission Rate Throughput request of AT[Byte]]/({1024}*
[%] Stat [Total RLP Octets Sent on
Forward Channels[KB]]))

Reverse Link Data % RLP {100}*([Octets Resent on


Retransmission Rate Throughput request of AN[Byte]]/({1024}
[%] Stat *[RLP Octets Received on
Reverse Channels[KB]]))

Network Forward RLP kiloby Performance ([Total RLP Octets Sent on


Capabilit Throughput[kbps] tes/ Stat of EV- Forward Channels[KB]]*{8})/
y secon DO Service {GP}
d Data
Throughput

Reverse RLP kbit/s RLP ([RLP Octets Received on


Throughput[kbps] Throughput Reverse Channels[KB]]*{8})/
Stat {GP}

Traffic Density on Erl EV-DO BSC ([DO 0 Traffic Channel


TCH[Erl] Traffic Connection Total time(DO 0)
Performance [Second]]+[DO A Traffic
Stat Channel Connection Total time
(DO A) [Second]])/{GP}

CS With PS(Not Erl Carrier ([Density of Traffic Carried on


Including HO) Traffic TCH (Excluding HO) (CS-
Performance FCH)[Erl]]+[Density of
Stat(FCH) Traffic Carried on TCH
(Excluding HO) (PS-FCH)
[Erl]])

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 520


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Network Soft HO Ratio % EV-DO ([DO 0 Traffic Channel CE


Coverage Carrier Total time(DO 0) [Second]]+
Traffic [DO A Traffic Channel CE
Performance Total time(DO A) [Second]]-
Stat [DO A Traffic Channel
Connection Total time(DO A)
[Second]]-[DO 0 Traffic
Channel Connection Total time
(DO 0) [Second]])/([DO 0
Traffic Channel CE Total time
(DO 0) [Second]]+[DO A
Traffic Channel CE Total time
(DO A) [Second]])*{100}

Resource CS With PS Erl Carrier ([CE Traffic Density - Speech


Usage (Including Soft HO) Traffic Service FCH[Erl]]+[CE
Ratio Performance Traffic Density - Packet
Stat(FCH) Service FCH[Erl]]+[CE
Traffic Density-PS SCH[Erl]])

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

8.3.10 Overview of Network Performance Report

Report Type
Simple Report

NE Type
CBSC

Object Type
CBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 521


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

HRPD HRPD Session Setup % Performance ([Successful HRPD Session


Session Success Ratio[%] Stat of BSC setup[Times]]/[HRPD Session
Performa HRPD setup Requests[Times]])*
nce KPI Sessions {100}
Group
HRPD Session Setup ms Performance -
Average Time Stat of
[Millisecond] Carrier
HRPD
Sessions

Maximum number of numb Performance -


active HRPD er Stat of BSC
Sessions[Entries] HRPD
Sessions

Maximum HRPD numb Performance -


Sessions[Entries] er Stat of BSC
HRPD
Sessions

Access % Performance ([Successful Access


Authentication Stat of BSC Authentications[Times]]/
Success Ratio[%] HRPD [Access Authentication
Sessions Attempts[Times]])*{100}

Accessab EV-DO Paging % Performance [Successful EV-DO Paging


lity KPI Success Ratio[%] Stat of BSC Times[Times]]/[EV-DO
Group HRPD Paging Attempts[Times]]*
Sessions {100}

Connection Success % Performance ([Successful Connection Times


Ratio[%] Stat of BSC [Times]]/[Connection
EV-DO Requests[Times]])*{100}
Connection
Setup

Call Connection Drop % Performance (([Connection Released (RF


Retainabi Ratio[%] Stat of BSC lost)[Times]]+[Connection
lity KPI EV-DO Released (Other causes)
Group Connection [Times]])/[Successful
Release Connection Times[Times]])*
{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 522


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Traffic Drop Ratio none Performance ([DO 0 Traffic Channel


[Minute] Stat of BSC Connection Total time(DO 0)
EV-DO [Second]]+[DO A Traffic
Connection Channel Connection Total time
Release (DO A) [Second]])/
(([Connection Released (RF
lost)[Times]]+[Connection
Release (HHO Fail)[Times]]+
[Connection Released (Other
causes)[Times]])*{GP})

Mobility Intra-AN Hard HO % Performance ([Successful Intra-AN Hard


KPI Success Ratio[%] Stat of Intra- HOs[Times]]/[Intra-AN Hard
Group AN Hard HO HO Requests[Times]])*{100}

Inter-subnet % Performance ([Successful Inter-subnet HOs


Dormant HO Success Stat of BSC within same AN[Times]]+
Ratio[%] HRPD [Successful Inter-subnet HOs
Sessions between ANs[Times]])/([Inter-
subnet HO (within same AN)
Attempts[Times]]+[Inter-
subnet HO (between ANs)
Attempts[Times]])*{100}

Successful Inter-AN % Performance ([Successful Inter-AN


Incoming Hard HOs Stat of Inter- Incoming Hard HOs[Times]]/
Ratio[%] AN Hard HO [Inter-AN Incoming Hard HO
Requests[Times]])*{100}

Successful Inter-AN % Performance ([Successful Inter-AN Hard


Hard HOs Ratio[%] Stat of Inter- HOs[Times]]/[Inter-AN Hard
AN Hard HO HO Requests[Times]])*{100}

Location Update % Performance (([Location Update Attempts


Assignment Success Stat of BSC (Location Notification
Ratio[%] HRPD Received)[Times]]-[Location
Sessions Update Uncompletion(No
Location Complete Received)
[Times]])/[Location Update
Attempts(Location
Notification Received)
[Times]])*{100}

Intra-AN Soft HO % Performance [Successful Intra-BS Soft HO


Success Ratio[%] Stat of EV-DO[Times]]/[Intra-BS
Carrier EV- Soft HO requests EV-DO
DO Reverse [Times]]*{100}
Channel Soft
HO

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 523


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Service Forward Link Data % RLP {100}*([Octets Resent on


Integrity Retransmission Rate Throughput request of AT[Byte]]/({1024}*
KPI [%] Stat [Total RLP Octets Sent on
Group Forward Channels[KB]]))

Reverse Link Data % RLP {100}*([Octets Resent on


Retransmission Rate Throughput request of AN[Byte]]/({1024}
[%] Stat *[RLP Octets Received on
Reverse Channels[KB]]))

Capabilit Traffic Density on Erl EV-DO BSC ([DO 0 Traffic Channel


y KPI TCH[Erl] Traffic Connection Total time(DO 0)
Group Performance [Second]]+[DO A Traffic
Stat Channel Connection Total time
(DO A) [Second]])/{GP}

CS With PS(Not Erl Carrier ([Density of Traffic Carried on


Including HO) Traffic TCH (Excluding HO) (CS-
Performance FCH)[Erl]]+[Density of
Stat(FCH) Traffic Carried on TCH
(Excluding HO) (PS-FCH)
[Erl]])

Coverage Soft HO Ratio % EV-DO ([DO 0 Traffic Channel CE


KPI Carrier Total time(DO 0) [Second]]+
Group Traffic [DO A Traffic Channel CE
Performance Total time(DO A) [Second]]-
Stat [DO A Traffic Channel
Connection Total time(DO A)
[Second]]-[DO 0 Traffic
Channel Connection Total time
(DO 0) [Second]])/([DO 0
Traffic Channel CE Total time
(DO 0) [Second]]+[DO A
Traffic Channel CE Total time
(DO A) [Second]])*{100}

Resource CS With PS Erl Carrier ([CE Traffic Density - Speech


Usage (Including Soft HO) Traffic Service FCH[Erl]]+[CE
Ratio Performance Traffic Density - Packet
Stat(FCH) Service FCH[Erl]]+[CE
Traffic Density-PS SCH[Erl]])

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 524


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 8 CDMA BSS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 525


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 9 CHLR Performance Report

9 CHLR Performance Report

About This Chapter

9.1 CHLR NE Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 526


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 9 CHLR Performance Report

9.1 CHLR NE Report


Report Type
Simple Report

NE Type
CHLR

Object Type
CHLR

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

CHLR Number of HDB times Internal -


Directives for Traffic Interface
Control Started Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 527


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 10 CMSC Performance Report

10 CMSC Performance Report

About This Chapter

10.1 CMSC NE Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 528


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 10 CMSC Performance Report

10.1 CMSC NE Report


Report Type
Simple Report

NE Type
CMSC

Object Type
CMSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

CMSC Broadcast Short times Broadcast -


Message First Paging Paging
Measuremen
t

Broadcast Paging No times Broadcast -


Response Paging
Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 529


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 11 GGSN Performance Report

11 GGSN Performance Report

About This Chapter

11.1 AAA performance Report

11.2 Session Service Report

11.3 Data transfer Report

11.4 System Resource Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 530


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 11 GGSN Performance Report

11.1 AAA performance Report


Report Type
Simple Report

NE Type
GGSN

Object Type
UGW and GGSN

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

AAA Authentication times AAA -


performa requests performance
nce measurement

Authentication % AAA {100}*[Successful


successful ratio performance authentication requests]/
measurement [Authentication requests]

Accounting start times AAA -


requests performance
measurement

Accounting start % AAA {100}*[Successful accounting


successful ratio performance start requests]/[Accounting
measurement start requests]

Accounting stop times AAA -


requests performance
measurement

Accounting stop % AAA {100}*[Successful accounting


successful ratio performance stop requests]/[Accounting
measurement stop requests]

Real-time accounting times AAA -


requests performance
measurement

Real time accounting % AAA {100}*[Successful real-time


ratio performance accounting requests]/[Real-
measurement time accounting requests]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 531


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 11 GGSN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

APN Authentication times AAA -


AAA requests performance
Performa measurement
nce (specified
APN)

Authentication % AAA {100}*[Successful


request success ratio performance authentication requests]/
measurement [Authentication requests]
(specified
APN)

Accounting start times AAA -


requests performance
measurement
(specified
APN)

Accounting request % AAA {100}*[Successful accounting


success ratio performance start requests]/[Accounting
measurement start requests]
(specified
APN)

Accounting stop times AAA -


requests performance
measurement
(specified
APN)

Accounting stop % AAA {100}*[Successful accounting


success ratio performance stop requests]/[Accounting
measurement stop requests]
(specified
APN)

Real-time accounting times AAA -


requests performance
measurement
(specified
APN)

Real time accounting % AAA {100}*[Successful real-time


request success ratio performance accounting requests]/[Real-
measurement time accounting requests]
(specified
APN)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 532


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 11 GGSN Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

11.2 Session Service Report


Report Type
Simple Report

NE Type
GGSN

Object Type
UGW and GGSN

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Basic PDP context times GGSN Basic -


session activation requests session
service performance
measurement

PDP context act % GGSN Basic {100}*[Successful PDP


success ratio session context activations]/[PDP
performance context activation requests]
measurement

Current activated numb GGSN Basic -


PDP contexts er session
performance
measurement

Apn GTPv1 MS-init. times GTPv1 -


session activation requests session
performa measurement
nce (specified
APN)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 533


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 11 GGSN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

GTPv1 MS act PDP % GTPv1 {100}*[Successful GTPv1


context success ratio session MS-init. activations]/[GTPv1
measurement MS-init. activation requests]
(specified
APN)

GTPv0 MS-init. times GTPv0 -


activation requests session
measurement
(specified
APN)

GTPv0 MS act PDP % GTPv0 {100}*[Successful GTPv0


context success ratio session MS-init. activations]/[GTPv0
measurement MS-init. activation requests]
(specified
APN)

Current activated numb Session -


PDP contexts (APN) er status
measurement
(specified
APN)

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

11.3 Data transfer Report


Report Type
Simple Report

NE Type
GGSN

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 534


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 11 GGSN Performance Report

Object Type
UGW and GGSN

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Data Gn peak throughput mb/ GGSN -


transfer in MB/s secon Forwarding
measure d performance
ment measurement

Gi peak throughput mb/ GGSN -


in MB/s secon Forwarding
d performance
measurement

Gn uplink traffic in MB GGSN -


MB Forwarding
performance
measurement

Gn downlink traffic MB GGSN -


in MB Forwarding
performance
measurement

Gi uplink traffic in MB GGSN -


MB Forwarding
performance
measurement

Gi downlink traffic in MB GGSN -


MB Forwarding
performance
measurement

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 535


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 11 GGSN Performance Report

11.4 System Resource Report


Report Type
Simple Report

NE Type
GGSN

Object Type
Board

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

System Average CPU usage % System -


Resource resources
Measure performance
ment measurement
(BOARD)

Peak CPU usage % System -


resources
performance
measurement
(BOARD)

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 536


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 12 HLR Performance Report

12 HLR Performance Report

About This Chapter

12.1 HLR NE Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 537


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 12 HLR Performance Report

12.1 HLR NE Report


Report Type
Simple Report

NE Type
HLR

Object Type
HLR Function

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

HLR 2G OCSI Subscribers entrie 2G CAMEL -


Function s Subscriber
Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 538


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 13 eRAN Performance Report

13 eRAN Performance Report

About This Chapter

13.1 LTE Reports

13.2 BTS Energy Consumption Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 539


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 13 eRAN Performance Report

13.1 LTE Reports

13.1.1 Accessibility Report

Report Type
Simple Report

NE Type
LTE

Object Type
LTE Cell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Accessib RRC Connection none Measuremen ([L.RRC.ConnReq.Succ.Emc]


ility Setup Success Rate t related to +
(service) RRC setup [L.RRC.ConnReq.Succ.High-
Pri]+
[L.RRC.ConnReq.Succ.Mt]+
[L.RRC.ConnReq.Succ.MoD-
ata])/
([L.RRC.ConnReq.Att.Emc]+
[L.RRC.ConnReq.Att.High-
Pri]+
[L.RRC.ConnReq.Att.Mt]+
[L.RRC.ConnReq.Att.MoDa-
ta])*{100}

RRC Connection none Measuremen ([L.RRC.ConnReq.Succ.Mo-


Setup Success Rate t related to Sig])/
(other)[%] RRC setup ([L.RRC.ConnReq.Att.Mo-
Sig])*{100}

E-RAB Setup none Measuremen ([L.E-RAB.SuccEst.QCI.1])/


Success Rate (VoIP) t related to E- ([L.E-RAB.AttEst.QCI.1])*
RAB {100}
establish

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 540


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 13 eRAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

E-RAB Setup none Measuremen ([L.E-RAB.SuccEst.QCI.1]+


Success Rate (All) t related to E- [L.E-RAB.SuccEst.QCI.2]+
RAB [L.E-RAB.SuccEst.QCI.3]+
establish [L.E-RAB.SuccEst.QCI.4]+
[L.E-RAB.SuccEst.QCI.5]+
[L.E-RAB.SuccEst.QCI.6]+
[L.E-RAB.SuccEst.QCI.7]+
[L.E-RAB.SuccEst.QCI.8]+
[L.E-RAB.SuccEst.QCI.9])/
([L.E-RAB.AttEst.QCI.1]+
[L.E-RAB.AttEst.QCI.2]+
[L.E-RAB.AttEst.QCI.3]+
[L.E-RAB.AttEst.QCI.4]+
[L.E-RAB.AttEst.QCI.5]+
[L.E-RAB.AttEst.QCI.6]+
[L.E-RAB.AttEst.QCI.7]+
[L.E-RAB.AttEst.QCI.8]+
[L.E-RAB.AttEst.QCI.9])*
{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

13.1.2 Integrity Report

Report Type
Simple Report

NE Type
LTE

Object Type
LTE Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 541


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 13 eRAN Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Integrity DL Average none Measuremen [L.Thrp.bits.DL.QCI.1]/


Throughput of QCI 1 t related to [L.Thrp.Time.DL.QCI.1]
Thruput

DL Average none Measuremen [L.Thrp.bits.DL.QCI.2]/


Throughput of QCI 2 t related to [L.Thrp.Time.DL.QCI.2]
Thruput

DL Average none Measuremen [L.Thrp.bits.DL.QCI.3]/


Throughput of QCI 3 t related to [L.Thrp.Time.DL.QCI.3]
Thruput

DL Average none Measuremen [L.Thrp.bits.DL.QCI.4]/


Throughput of QCI 4 t related to [L.Thrp.Time.DL.QCI.4]
Thruput

DL Average none Measuremen [L.Thrp.bits.DL.QCI.5]/


Throughput of QCI 5 t related to [L.Thrp.Time.DL.QCI.5]
Thruput

DL Average none Measuremen [L.Thrp.bits.DL.QCI.6]/


Throughput of QCI 6 t related to [L.Thrp.Time.DL.QCI.6]
Thruput

DL Average none Measuremen [L.Thrp.bits.DL.QCI.7]/


Throughput of QCI 7 t related to [L.Thrp.Time.DL.QCI.7]
Thruput

DL Average none Measuremen [L.Thrp.bits.DL.QCI.8]/


Throughput of QCI 8 t related to [L.Thrp.Time.DL.QCI.8]
Thruput

DL Average none Measuremen [L.Thrp.bits.DL.QCI.9]/


Throughput of QCI 9 t related to [L.Thrp.Time.DL.QCI.9]
Thruput

UL Average none Measuremen [L.Thrp.bits.UL.QCI.1]/


Throughput of QCI 1 t related to [L.Thrp.Time.UL.QCI.1]
Thruput

UL Average none Measuremen [L.Thrp.bits.UL.QCI.2]/


Throughput of QCI 2 t related to [L.Thrp.Time.UL.QCI.2]
Thruput

UL Average none Measuremen [L.Thrp.bits.UL.QCI.3]/


Throughput of QCI 3 t related to [L.Thrp.Time.UL.QCI.3]
Thruput

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 542


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 13 eRAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

UL Average none Measuremen [L.Thrp.bits.UL.QCI.4]/


Throughput of QCI 4 t related to [L.Thrp.Time.UL.QCI.4]
Thruput

UL Average none Measuremen [L.Thrp.bits.UL.QCI.5]/


Throughput of QCI 5 t related to [L.Thrp.Time.UL.QCI.5]
Thruput

UL Average none Measuremen [L.Thrp.bits.UL.QCI.6]/


Throughput of QCI 6 t related to [L.Thrp.Time.UL.QCI.6]
Thruput

UL Average none Measuremen [L.Thrp.bits.UL.QCI.7]/


Throughput of QCI 7 t related to [L.Thrp.Time.UL.QCI.7]
Thruput

UL Average none Measuremen [L.Thrp.bits.UL.QCI.8]/


Throughput of QCI 8 t related to [L.Thrp.Time.UL.QCI.8]
Thruput

UL Average none Measuremen [L.Thrp.bits.UL.QCI.9]/


Throughput of QCI 9 t related to [L.Thrp.Time.UL.QCI.9]
Thruput

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

13.1.3 LTE KPI Overview Report

Report Type
Simple Report

NE Type
LTE

Object Type
LTE Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 543


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 13 eRAN Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Accesaib RRC Connection none Measuremen ([L.RRC.ConnReq.Succ.Emc]


ility Setup Success Rate t related to +
(service) RRC setup [L.RRC.ConnReq.Succ.High-
Pri]+
[L.RRC.ConnReq.Succ.Mt]+
[L.RRC.ConnReq.Succ.MoD-
ata])/
([L.RRC.ConnReq.Att.Emc]+
[L.RRC.ConnReq.Att.High-
Pri]+
[L.RRC.ConnReq.Att.Mt]+
[L.RRC.ConnReq.Att.MoDa-
ta])*{100}

RRC Connection none Measuremen ([L.RRC.ConnReq.Succ.Mo-


Setup Success Rate t related to Sig])/
(other)[%] RRC setup ([L.RRC.ConnReq.Att.Mo-
Sig])*{100}

E-RAB Setup none Measuremen ([L.E-RAB.SuccEst.QCI.1]/


Success Rate (VoIP) t related to E- [L.E-RAB.AttEst.QCI.1])*
[%] RAB {100}
establish

E-RAB Setup none Measuremen ([L.E-RAB.SuccEst]/[L.E-


Success Rate (ALL) t related to E- RAB.AttEst])*{100}
[%] RAB
establish

Call Setup Success none Measuremen (([L.RRC.ConnReq.Succ.Emc


Rate(VoIP)[%] t related to ]+
RRC setup [L.RRC.ConnReq.Succ.High-
Pri]+
[L.RRC.ConnReq.Succ.Mt]+
[L.RRC.ConnReq.Succ.MoD-
ata])/
([L.RRC.ConnReq.Att.Emc]+
[L.RRC.ConnReq.Att.High-
Pri]+
[L.RRC.ConnReq.Att.Mt]+
[L.RRC.ConnReq.Att.MoDa-
ta])*{100})*(([L.E-
RAB.SuccEst.QCI.1]/[L.E-
RAB.AttEst.QCI.1])*{100})/
{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 544


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 13 eRAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Service Setup none Measuremen (([L.RRC.ConnReq.Succ.Emc


Success Rate(ALL) t related to ]+
[%] RRC setup [L.RRC.ConnReq.Succ.High-
Pri]+
[L.RRC.ConnReq.Succ.Mt]+
[L.RRC.ConnReq.Succ.MoD-
ata])/
([L.RRC.ConnReq.Att.Emc]+
[L.RRC.ConnReq.Att.High-
Pri]+
[L.RRC.ConnReq.Att.Mt]+
[L.RRC.ConnReq.Att.MoDa-
ta])*{100})*(([L.E-
RAB.SuccEst]/[L.E-
RAB.AttEst])*{100})/{100}

Retainabi Call Drop Rate none Measuremen ([L.E-RAB.AbnormRel.QCI.


lity (VoIP)[%] t related to E- 1]/([L.E-RAB.NormRel.QCI.
RAB release 1]+[L.E-
RAB.AbnormRel.QCI.1]))*
{100}

Call Drop Rate (All) none Measuremen ([L.E-RAB.AbnormRel]/[L.E-


[%] t related to E- RAB.NormRel])*{100}
RAB release

Call Complete none Measuremen (([L.RRC.ConnReq.Succ.Emc


Success Rate(VoIP) t related to ]+
[%] RRC setup [L.RRC.ConnReq.Succ.High-
Pri]+
[L.RRC.ConnReq.Succ.Mt]+
[L.RRC.ConnReq.Succ.MoD-
ata])/
([L.RRC.ConnReq.Att.Emc]+
[L.RRC.ConnReq.Att.High-
Pri]+
[L.RRC.ConnReq.Att.Mt]+
[L.RRC.ConnReq.Att.MoDa-
ta])*{100})*(([L.E-
RAB.SuccEst.QCI.1]/[L.E-
RAB.AttEst.QCI.1])*{100})*
(([L.E-RAB.AbnormRel.QCI.
1]/([L.E-RAB.NormRel.QCI.
1]+[L.E-
RAB.AbnormRel.QCI.1]))*
{100})/{10000}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 545


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 13 eRAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Call Complete none Measuremen (([L.RRC.ConnReq.Succ.Emc


Success Rate(ALL) t related to ]+
[%] RRC setup [L.RRC.ConnReq.Succ.High-
Pri]+
[L.RRC.ConnReq.Succ.Mt]+
[L.RRC.ConnReq.Succ.MoD-
ata])/
([L.RRC.ConnReq.Att.Emc]+
[L.RRC.ConnReq.Att.High-
Pri]+
[L.RRC.ConnReq.Att.Mt]+
[L.RRC.ConnReq.Att.MoDa-
ta])*{100})*(([L.E-
RAB.SuccEst]/[L.E-
RAB.AttEst])*{100})*(([L.E-
RAB.AbnormRel]/[L.E-
RAB.NormRel])*{100})/
{10000}

Mobility Intra-frequency none Measuremen (([L.HHO.IntraeNB.IntraFreq.


Handover Out t related to ExecSuccOut]+
Success Rate[%] Intra eRan [L.HHO.IntereNB.IntraFreq.E
HOOUT xecSuccOut])/
([L.HHO.IntraeNB.IntraFreq.
ExecAttOut]+
[L.HHO.IntereNB.IntraFreq.E
xecAttOut]))*{100}

Inter-frequency none Measuremen (([L.HHO.IntraeNB.InterFreq.


Handover Out t related to ExecSuccOut]+
Success Rate[%] Intra eRan [L.HHO.IntereNB.InterFreq.E
HOOUT xecSuccOut])/
([L.HHO.IntraeNB.InterFreq.
ExecAttOut]+
[L.HHO.IntereNB.InterFreq.E
xecAttOut]))*{100}

Inter-RAT Handover none Measuremen ([L.IRATHO.E2C.ExecSucc-


Out Success Rate t related to Out]/[L.IRATHO.E2C.Pre-
(LTE to CDMA) IRATHOOU pAttOut])*{100}
T

Inter-RAT Handover none Measuremen ([L.IRATHO.E2W.ExecSucc-


Out Success Rate t related to Out]/[L.IRATHO.E2W.Pre-
(LTE to WCDMA) IRATHOOU pAttOut])*{100}
T

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 546


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 13 eRAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Inter-RAT Handover none Measuremen ([L.IRATHO.E2G.ExecSucc-


Out Success Rate t related to Out]/[L.IRATHO.E2G.Pre-
(LTE to GERAN) IRATHOOU pAttOut])*{100}
T

Inter-RAT Handover none Measuremen ([L.IRATHO.E2T.ExecSucc-


Out Success Rate t related to Out]/[L.IRATHO.E2T.Pre-
(LTE to GERAN) IRATHOOU pAttOut])*{100}
T

Service UL Average none Measuremen ([L.Thrp.bits.UL.QCI.1]+


integrity Throughput(Kbps) t related to [L.Thrp.bits.UL.QCI.2]+
Thruput [L.Thrp.bits.UL.QCI.3]+
[L.Thrp.bits.UL.QCI.4]+
[L.Thrp.bits.UL.QCI.5]+
[L.Thrp.bits.UL.QCI.6]+
[L.Thrp.bits.UL.QCI.7]+
[L.Thrp.bits.UL.QCI.8]+
[L.Thrp.bits.UL.QCI.9])/
([L.Thrp.Time.UL.QCI.1]+
[L.Thrp.Time.UL.QCI.2]+
[L.Thrp.Time.UL.QCI.3]+
[L.Thrp.Time.UL.QCI.4]+
[L.Thrp.Time.UL.QCI.5]+
[L.Thrp.Time.UL.QCI.6]+
[L.Thrp.Time.UL.QCI.7]+
[L.Thrp.Time.UL.QCI.8]+
[L.Thrp.Time.UL.QCI.9])

DL Average none Measuremen ([L.Thrp.bits.DL.QCI.1]+


Throughput(Kbps) t related to [L.Thrp.bits.DL.QCI.2]+
Thruput [L.Thrp.bits.DL.QCI.3]+
[L.Thrp.bits.DL.QCI.4]+
[L.Thrp.bits.DL.QCI.5]+
[L.Thrp.bits.DL.QCI.6]+
[L.Thrp.bits.DL.QCI.7]+
[L.Thrp.bits.DL.QCI.8]+
[L.Thrp.bits.DL.QCI.9])/
([L.Thrp.Time.DL.QCI.1]+
[L.Thrp.Time.DL.QCI.2]+
[L.Thrp.Time.DL.QCI.3]+
[L.Thrp.Time.DL.QCI.4]+
[L.Thrp.Time.DL.QCI.5]+
[L.Thrp.Time.DL.QCI.6]+
[L.Thrp.Time.DL.QCI.7]+
[L.Thrp.Time.DL.QCI.8]+
[L.Thrp.Time.DL.QCI.9])

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 547


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 13 eRAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Availabil Wireless Network none Measuremen ([L.Cell.Unavail.Dur.Sys]+


ity Unavailable Rate t related to [L.Cell.Unavail.Dur.Manual])/
Cell {GP}*{60}
Algorithm

Traffic UL Trafic Volume none Measuremen [L.Thrp.bits.UL.QCI.1]+


(Mbps) t related to [L.Thrp.bits.UL.QCI.2]+
Thruput [L.Thrp.bits.UL.QCI.3]+
[L.Thrp.bits.UL.QCI.4]+
[L.Thrp.bits.UL.QCI.5]+
[L.Thrp.bits.UL.QCI.6]+
[L.Thrp.bits.UL.QCI.7]+
[L.Thrp.bits.UL.QCI.8]+
[L.Thrp.bits.UL.QCI.9]

DL Trafic Volume none Measuremen [L.Thrp.bits.DL.QCI.1]+


(Mbps) t related to [L.Thrp.bits.DL.QCI.2]+
Thruput [L.Thrp.bits.DL.QCI.3]+
[L.Thrp.bits.DL.QCI.4]+
[L.Thrp.bits.DL.QCI.5]+
[L.Thrp.bits.DL.QCI.6]+
[L.Thrp.bits.DL.QCI.7]+
[L.Thrp.bits.DL.QCI.8]+
[L.Thrp.bits.DL.QCI.9]

L.Traffic.User.Avg none Measuremen -


t related to
the number of
User

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

13.1.4 Mobility Report

Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 548


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 13 eRAN Performance Report

NE Type
LTE

Object Type
LTE Cell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Mobility Intra-frequency none Measuremen ([L.HHO.IntraeNB.IntraFreq.


Handover Out t related to ExecSuccOut]+
Success Rate Intra eRan [L.HHO.IntereNB.IntraFreq.E
HOOUT xecSuccOut])/
([L.HHO.IntraeNB.IntraFreq.
ExecAttOut]+
[L.HHO.IntereNB.IntraFreq.E
xecAttOut])*{100}

Inter-frequency none Measuremen ([L.HHO.IntraeNB.InterFreq.


Handover Out t related to ExecSuccOut]+
Success Rate Intra eRan [L.HHO.IntereNB.InterFreq.E
HOOUT xecSuccOut])/
([L.HHO.IntraeNB.InterFreq.
ExecAttOut]+
[L.HHO.IntereNB.InterFreq.E
xecAttOut])*{100}

Inter-RAT Handover none Measuremen ([L.IRATHO.E2C.ExecSucc-


Out Success Rate t related to Out])/([L.IRATHO.E2C.Exe-
(LTE to CDMA) IRATHOOU cAttOut])*{100}
T

Inter-RAT Handover none Measuremen ([L.IRATHO.E2W.ExecSucc-


Out Success Rate t related to Out])/([L.IRATHO.E2W.Exe-
(LTE to WCDMA) IRATHOOU cAttOut])*{100}
T

Inter-RAT Handover none Measuremen ([L.IRATHO.E2G.ExecSucc-


Out Success Rate t related to Out])/([L.IRATHO.E2G.Exe-
(LTE to GSM) IRATHOOU cAttOut])*{100}
T

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 549


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 13 eRAN Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

13.1.5 Retainability Report

Report Type
Simple Report

NE Type
LTE

Object Type
LTE Cell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Retainabi Call Drop Rate none Measuremen ([L.E-RAB.AbnormRel.QCI.


lity (VoIP) t related to E- 1])/([L.E-
RAB release RAB.AbnormRel.QCI.1]+
[L.E-RAB.NormRel.QCI.1])*
{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 550


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 13 eRAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Service Drop Rate none Measuremen ((([L.E-


(All) t related to E- RAB.AbnormRel.QCI.1]+
RAB release [L.E-RAB.AbnormRel.QCI.2]
+[L.E-RAB.AbnormRel.QCI.
3]+[L.E-
RAB.AbnormRel.QCI.4]+
[L.E-RAB.AbnormRel.QCI.5]
+[L.E-RAB.AbnormRel.QCI.
6]+[L.E-
RAB.AbnormRel.QCI.7]+
[L.E-RAB.AbnormRel.QCI.8]
+[L.E-RAB.AbnormRel.QCI.
9])))/((([L.E-
RAB.AbnormRel.QCI.1]+
[L.E-RAB.AbnormRel.QCI.2]
+[L.E-RAB.AbnormRel.QCI.
3]+[L.E-
RAB.AbnormRel.QCI.4]+
[L.E-RAB.AbnormRel.QCI.5]
+[L.E-RAB.AbnormRel.QCI.
6]+[L.E-
RAB.AbnormRel.QCI.7]+
[L.E-RAB.AbnormRel.QCI.8]
+[L.E-RAB.AbnormRel.QCI.
9]+[L.E-RAB.NormRel.QCI.
1]+[L.E-RAB.NormRel.QCI.
2]+[L.E-RAB.NormRel.QCI.
3]+[L.E-RAB.NormRel.QCI.
4]+[L.E-RAB.NormRel.QCI.
5]+[L.E-RAB.NormRel.QCI.
6]+[L.E-RAB.NormRel.QCI.
7]+[L.E-RAB.NormRel.QCI.
8]+[L.E-RAB.NormRel.QCI.
9])))*{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 551


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 13 eRAN Performance Report

13.1.6 Traffic Report

Report Type
Simple Report

NE Type
LTE

Object Type
LTE Cell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Traffic Radio Bearers of QCI none Measuremen [L.Traffic.DRB.QCI.1]


1 t related to
DRB

Radio Bearers of QCI none Measuremen [L.Traffic.DRB.QCI.2]


2 t related to
DRB

Radio Bearers of QCI none Measuremen [L.Traffic.DRB.QCI.3]


3 t related to
DRB

Radio Bearers of QCI none Measuremen [L.Traffic.DRB.QCI.4]


4 t related to
DRB

Radio Bearers of QCI none Measuremen [L.Traffic.DRB.QCI.5]


5 t related to
DRB

Radio Bearers of QCI none Measuremen [L.Traffic.DRB.QCI.6]


6 t related to
DRB

Radio Bearers of QCI none Measuremen [L.Traffic.DRB.QCI.7]


7 t related to
DRB

Radio Bearers of QCI none Measuremen [L.Traffic.DRB.QCI.8]


8 t related to
DRB

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 552


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 13 eRAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Radio Bearers of QCI none Measuremen [L.Traffic.DRB.QCI.9]


9 t related to
DRB

DL Traffic Volume none Measuremen [L.Thrp.bits.DL.QCI.1]


of QCI 1 t related to
Thruput

DL Traffic Volume none Measuremen [L.Thrp.bits.DL.QCI.2]


of QCI 2 t related to
Thruput

DL Traffic Volume none Measuremen [L.Thrp.bits.DL.QCI.3]


of QCI 3 t related to
Thruput

DL Traffic Volume none Measuremen [L.Thrp.bits.DL.QCI.4]


of QCI 4 t related to
Thruput

DL Traffic Volume none Measuremen [L.Thrp.bits.DL.QCI.5]


of QCI 5 t related to
Thruput

DL Traffic Volume none Measuremen [L.Thrp.bits.DL.QCI.6]


of QCI 6 t related to
Thruput

DL Traffic Volume none Measuremen [L.Thrp.bits.DL.QCI.7]


of QCI 7 t related to
Thruput

DL Traffic Volume none Measuremen [L.Thrp.bits.DL.QCI.8]


of QCI 8 t related to
Thruput

DL Traffic Volume none Measuremen [L.Thrp.bits.DL.QCI.9]


of QCI 9 t related to
Thruput

UL Traffic Volume none Measuremen [L.Thrp.bits.UL.QCI.1]


of QCI 1 t related to
Thruput

UL Traffic Volume none Measuremen [L.Thrp.bits.UL.QCI.2]


of QCI 2 t related to
Thruput

UL Traffic Volume none Measuremen [L.Thrp.bits.UL.QCI.3]


of QCI 3 t related to
Thruput

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 553


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 13 eRAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

UL Traffic Volume none Measuremen [L.Thrp.bits.UL.QCI.4]


of QCI 4 t related to
Thruput

UL Traffic Volume none Measuremen [L.Thrp.bits.UL.QCI.5]


of QCI 5 t related to
Thruput

UL Traffic Volume none Measuremen [L.Thrp.bits.UL.QCI.6]


of QCI 6 t related to
Thruput

UL Traffic Volume none Measuremen [L.Thrp.bits.UL.QCI.7]


of QCI 7 t related to
Thruput

UL Traffic Volume none Measuremen [L.Thrp.bits.UL.QCI.8]


of QCI 8 t related to
Thruput

UL Traffic Volume none Measuremen [L.Thrp.bits.UL.QCI.9]


of QCI 9 t related to
Thruput

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

13.2 BTS Energy Consumption Report

13.2.1 BTS Traffic and Energy Consumption Report

Report Type
Simple Report

NE Type
LTE

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 554


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 13 eRAN Performance Report

Object Type
LTE Cell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

BTS Energy Consumption none Measuremen [L.Device.eNodeB.Energy-


Traffic (kwh) t related to Consume]
and eNodeB
Energy
Consump PS Traffic(kbit) none Thruput ([L.Thrp.bits.DL.QCI.1]+
tion Measuremen [L.Thrp.bits.DL.QCI.2]+
Report t Unit [L.Thrp.bits.DL.QCI.3]+
[L.Thrp.bits.DL.QCI.4]+
[L.Thrp.bits.DL.QCI.5]+
[L.Thrp.bits.DL.QCI.6]+
[L.Thrp.bits.DL.QCI.7]+
[L.Thrp.bits.DL.QCI.8]+
[L.Thrp.bits.DL.QCI.9])/
{1000}

Total Traffic(kbit) none Thruput ([L.Thrp.bits.DL.QCI.1]+


Measuremen [L.Thrp.bits.DL.QCI.2]+
t Unit [L.Thrp.bits.DL.QCI.3]+
[L.Thrp.bits.DL.QCI.4]+
[L.Thrp.bits.DL.QCI.5]+
[L.Thrp.bits.DL.QCI.6]+
[L.Thrp.bits.DL.QCI.7]+
[L.Thrp.bits.DL.QCI.8]+
[L.Thrp.bits.DL.QCI.9])/
{1000}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

13.2.2 Network Energy Efficiency Indicator Report


Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 555


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 13 eRAN Performance Report

NE Type
LTE

Object Type
LTE Cell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Network EE(bit/joule) none Thruput ([L.Thrp.bits.DL.QCI.1]+


Energy Measuremen [L.Thrp.bits.DL.QCI.2]+
Efficienc t Unit [L.Thrp.bits.DL.QCI.3]+
y [L.Thrp.bits.DL.QCI.4]+
Indicator [L.Thrp.bits.DL.QCI.5]+
Report [L.Thrp.bits.DL.QCI.6]+
[L.Thrp.bits.DL.QCI.7]+
[L.Thrp.bits.DL.QCI.8]+
[L.Thrp.bits.DL.QCI.9])/
{1000}/
[L.Device.eNodeB.Energy-
Consume]/{3600}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 556


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 14 MGW Performance Report

14 MGW Performance Report

About This Chapter

14.1 MGW NE Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 557


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 14 MGW Performance Report

14.1 MGW NE Report


Report Type
Simple Report

NE Type
MGW

Object Type
MGW

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

MGW Number of total numb H.248 SCTP -


NE received H248 bytes er Signaling
Link Set
Measuremen
t of the
Whole
Equipment

Number of total numb H.248 SCTP -


received H248 er Signaling
messages Link Set
Measuremen
t of the
Whole
Equipment

Failed Request numb Statistics of -


Number Because of er EC
Busy Occupation
of the Whole
Equipment

Configured Number numb Statistics of -


er EC
Occupation
of the Whole
Equipment

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 558


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 14 MGW Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 559


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 15 MSCe Performance Report

15 MSCe Performance Report

About This Chapter

15.1 System LoadSpecific KPI Report

15.2 Basic Telecom ServiceSpecific KPI Report

15.3 ServiceSpecific KPI Report

15.4 Mobility ManagementSpecific KPI Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 560


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 15 MSCe Performance Report

15.1 System LoadSpecific KPI Report

15.1.1 Number of Subscribers Registered with the VLR Report

Report Type
Simple Report

NE Type
MSCe

Object Type
MSCe

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Number Local Subscribers entrie VLR -


of s Subscriber
Subscrib Measuremen
ers t

Roaming entrie VLR -


Subscribers s Subscriber
Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

15.1.2 Processor Load Report

Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 561


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 15 MSCe Performance Report

NE Type
MSCe

Object Type
Module

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Processo Average CPU Usage % CPU Usage -


r Load Measuremen
t

Peak CPU Usage % CPU Usage -


Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

15.1.3 Load over Signaling Links Report

Report Type
Simple Report

NE Type
MSCe

Object Type
MTP Signaling Link

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 562


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 15 MSCe Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Load Send Seizure Ratio % MTP -


over Signaling
Signaling Link Traffic
Links Measuremen
t

Received Seizure % MTP -


Ratio Signaling
Link Traffic
Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

15.1.4 Load over Trunk Circuits Report

Report Type
Simple Report

NE Type
MSCe

Object Type
Office Direction

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 563


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 15 MSCe Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Load Traffic Per Trunk Erl Incoming -


over (Incoming) Office
Trunk Measuremen
Circuits t Based on
Office
Direction

Traffic Per Trunk Erl Outgoing -


(Outgoing) Office
Measuremen
t Based on
Office
Direction

Trunk Outgoing times Outgoing -


Overflows Office
Measuremen
t Based on
Office
Direction

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

15.2 Basic Telecom ServiceSpecific KPI Report


Report Type
Simple Report

NE Type
MSCe

Object Type
MSCe

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 564


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 15 MSCe Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Basic MOC TCH times Assignment -


Telecom Assignment Procedure
ServiceS Requests Measuremen
pecific t
KPI
MTC TCH times Assignment -
Assignment Procedure
Requests Measuremen
t

Assignment Success % Assignment ([Successful MOC TCH


Ratio(%) Procedure Assignments]+[Successful
Measuremen MTC TCH Assignments])/
t ([MOC TCH Assignment
Requests]+[MTC TCH
Assignment Requests])*{100}

Pagings times MTC -


Completion
Measuremen
t

Paging Success Ratio % MTC [Paging Responses]/[Pagings]


(%) Completion *{100}
Measuremen
t

Call Attempts (ORG) times Originating -


Traffic
Measuremen
t

Call Attempts(IEX) times Incoming -


Traffic
Measuremen
t

Call Completion % Originating ([Calls Connected(ORG)]+


Ratio(%) Traffic [Calls Connected(IEX)])/
Measuremen ([Call Attempts (ORG)]+[Call
t Attempts(IEX)])*{100}

Calls Connected times Originating -


(ORG) Traffic
Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 565


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 15 MSCe Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Calls Connected times Incoming -


(IEX) Traffic
Measuremen
t

Call Answer Ratio % Originating ([Calls Answered(ORG)]+


(%) Traffic [Calls Answered(IEX)])/
Measuremen ([Calls Connected(ORG)]+
t [Calls Connected(IEX)])*
{100}

Answered Traffic Erl Incoming -


(IEX) Traffic
Measuremen
t

Answered Traffic Erl Originating -


(ORG) Traffic
Measuremen
t

Answered Traffic Erl Originating [Answered Traffic(ORG)]+


(erl) Traffic [Answered Traffic(IEX)]
Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

15.3 ServiceSpecific KPI Report


Report Type
Simple Report

NE Type
MSCe

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 566


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 15 MSCe Performance Report

Object Type
MSCe

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

ServiceS MO Short Message times Short -


pecific Submission Message
KPI Attempts Service
Measuremen
t

SMS Origination % Short [Successful MO Short Message


Success Ratio(%) Message Submissions]/[MO Short
Service Message Submission
Measuremen Attempts]*{100}
t

MT Short Message times Short -


Submission Message
Attempts Service
Measuremen
t

SMS Termination % Short [Successful MT Short Message


Success Ratio(%) Message Submissions]/[MT Short
Service Message Submission
Measuremen Attempts]*{100}
t

Originating Calls times PDSN -


Traffic
Measuremen
t

PDSN Origination % PDSN [Successful Call Origination]/


Success Ratio(%) Traffic [Originating Calls]*{100}
Measuremen
t

Call Termination times PDSN -


Traffic
Measuremen
t

PDSN Termination % PDSN [Successful Call Termination]/


Success Ratio(%) Traffic [Call Termination]*{100}
Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 567


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 15 MSCe Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

15.4 Mobility ManagementSpecific KPI Report


Report Type
Simple Report

NE Type
MSCe

Object Type
MSCe

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Mobility Location Update times Location -


Manage Requests Management
mentSpe Service
cific KPI Measuremen
t

Location Update % Location [Successful Location Updates]/


Success Ratio(%) Management [Location Update Requests]*
Service {100}
Measuremen
t

Authentication times Authenticati -


Attempts on Service
Measuremen
t

Authentication % Authenticati [Successful Authentications]/


Success Ratio(%) on Service [Authentication Attempts]*
Measuremen {100}
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 568


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 15 MSCe Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Handoff Success % Handoff ([Successful Intra-MSC Hard


Ratio(%) Measuremen Handoffs]+[Successful
t Incoming Handoff Back]+
[Successful Incoming Handoff
Forward]+[Successful
Incoming Handoff to Third]+
[Successful Outgoing Handoff
Back]+[Successful Outgoing
Handoff Forward]+
[Successful Outgoing Handoff
to Third])/([Intra-MSC Hard
Handoff Requests]+[Incoming
Handoff Back Requests]+
[Incoming Handoff Forward
Requests]+[Incoming Handoff
to Third Requests]+[Outgoing
Handoff Back Requests]+
[Outgoing Handoff Forward
Requests]+[Outgoing Handoff
to Third Requests])*{100}

Intra-MSC Hard times Handoff -


Handoff Requests Measuremen
t

Intra-office Handoff % Handoff [Successful Intra-MSC Hard


Success Ratio(%) Measuremen Handoffs]/[Intra-MSC Hard
t Handoff Requests]*{100}

Successful Incoming times Inter-Office -


Handoff Back Handoff
Measuremen
t

Incoming Handoff times Inter-Office -


Back Requests Handoff
Measuremen
t

Successful Incoming times Inter-Office -


Handoff Forward Handoff
Measuremen
t

Incoming Handoff times Inter-Office -


Forward Requests Handoff
Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 569


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 15 MSCe Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Successful Incoming times Inter-Office -


Handoff to Third Handoff
Measuremen
t

Incoming Handoff to times Inter-Office -


Third Requests Handoff
Measuremen
t

Successful Outgoing times Inter-Office -


Handoff Back Handoff
Measuremen
t

Outgoing Handoff times Inter-Office -


Back Requests Handoff
Measuremen
t

Successful Outgoing times Inter-Office -


Handoff Forward Handoff
Measuremen
t

Outgoing Handoff times Inter-Office -


Forward Requests Handoff
Measuremen
t

Successful Outgoing times Inter-Office -


Handoff to Third Handoff
Measuremen
t

Outgoing Handoff to times Inter-Office -


Third Requests Handoff
Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 570


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 15 MSCe Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Inter-office Handoff % Inter-Office ([Successful Incoming


Success Ratio(%) Handoff Handoff Back]+[Successful
Measuremen Incoming Handoff Forward]+
t [Successful Incoming Handoff
to Third]+[Successful
Outgoing Handoff Back]+
[Successful Outgoing Handoff
Forward]+[Successful
Outgoing Handoff to Third])/
([Incoming Handoff Back
Requests]+[Incoming Handoff
Forward Requests]+[Incoming
Handoff to Third Requests]+
[Outgoing Handoff Back
Requests]+[Outgoing Handoff
Forward Requests]+[Outgoing
Handoff to Third Requests])*
{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 571


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 16 MSCServer Performance Report

16 MSCServer Performance Report

About This Chapter

16.1 Signalling Link Report

16.2 CPU Load

16.3 Basic MSC Service Report

16.4 Trunk Group Traffic

16.5 Office Direction Traffic

16.6 Mobility Management Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 572


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 16 MSCServer Performance Report

16.1 Signalling Link Report

16.1.1 BICC SCTP Link Report

Report Type
Simple Report

NE Type
MSCServer

Object Type
BICCLink

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

BICC Number of Sent entrie Traffic over -


SCTP Message Packets s BICC SCTP
Link Links

Number of Received entrie Traffic over -


Message Packets s BICC SCTP
Links

Bytes of Message MB Traffic over [Bytes of Sent Messages]/


Sent(MB) BICC SCTP {1048576}
Links

Bytes of Message MB Traffic over [Bytes of Received Messages]/


Received(MB) BICC SCTP {1048576}
Links

Congestion Times times Traffic over -


BICC SCTP
Links

Congestion Duration s Traffic over -


BICC SCTP
Links

Unavailable Times times Traffic over -


BICC SCTP
Links

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 573


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 16 MSCServer Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Unavailable s Traffic over -


Duration BICC SCTP
Links

Flow of Link(MB) MB Traffic over ([Bytes of Sent Messages]+


BICC SCTP [Bytes of Received
Links Messages])/{1048576}

Average Load of kbit/s Traffic over ([Rate of Sending Packets


Link(kbps) BICC SCTP (bps)]+[Rate of Receiving
Links Packets (bps)])/{1024}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

16.1.2 H248 SCTP Link Report

Report Type
Simple Report

NE Type
MSCServer

Object Type
H248Link

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

H248 Number of Sent times Traffic over -


SCTP Messages H.248 SCTP
Link Links

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 574


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 16 MSCServer Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Number of Received times Traffic over -


Messages H.248 SCTP
Links

Bytes of Message MB Traffic over [Bytes of Sent Messages]/


Sent(MB) H.248 SCTP {1048576}
Links

Bytes of Message MB Traffic over [Bytes of Received Messages]/


Received(MB) H.248 SCTP {1048576}
Links

Congestion Times times Traffic over -


H.248 SCTP
Links

Congestion Duration s Traffic over -


H.248 SCTP
Links

Unavailable Times times Traffic over -


H.248 SCTP
Links

Unavailable s Traffic over -


Duration H.248 SCTP
Links

Flow of Link(MB) MB Traffic over ([Bytes of Sent Messages]+


H.248 SCTP [Bytes of Received
Links Messages])/{1048576}

Average Load of kbit/s Traffic over ([Rate of Sending Packets


Link(kbps) H.248 SCTP (bps)]+[Rate of Sending
Links Packets (bps)])/{1024}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 575


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 16 MSCServer Performance Report

16.1.3 M2UA Link Report

Report Type
Simple Report

NE Type
MSCServer

Object Type
M2UALink

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

M2UA Number of Sent entrie Traffic over -


Link MAUP Messages s M2UA
Signaling
Links

Number of Received entrie Traffic over -


MAUP Messages s M2UA
Signaling
Links

Bytes of Message MB Traffic over [Bytes of Sent MAUP


Sent(MB) M2UA Messages]/{1048576}
Signaling
Links

Bytes of Message MB Traffic over [Bytes of Received MAUP


Received(MB) M2UA Messages]/{1048576}
Signaling
Links

Congestion Times times Traffic over -


M2UA
Signaling
Links

Congestion Duration s Traffic over -


M2UA
Signaling
Links

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 576


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 16 MSCServer Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Unavailable Times times Traffic over -


M2UA
Signaling
Links

Unavailable s Traffic over -


Duration M2UA
Signaling
Links

Average Load of kbit/s Traffic over ([Rate of Sending Packets


Link(kbps) M2UA (bps)]+[Rate of Receiving
Signaling Packets (bps)])/{1024}
Links

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

16.1.4 M3UA Link Report

Report Type
Simple Report

NE Type
MSCServer

Object Type
M3UALink

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 577


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 16 MSCServer Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

M3UA Number of Messages entrie Traffic over -


Link Sent s M3UA
Signaling
Links

Number of Messages entrie Traffic over -


Received s M3UA
Signaling
Links

Bytes of Message MB Traffic over [Bytes of Messages Sent]/


Sent(MB) M3UA {1048576}
Signaling
Links

Bytes of Message MB Traffic over [Bytes of Messages Received]/


Received(MB) M3UA {1048576}
Signaling
Links

Congestion Times times Traffic over -


M3UA
Signaling
Links

Congestion Duration s Traffic over -


M3UA
Signaling
Links

Unavailable Times times Traffic over -


M3UA
Signaling
Links

Unavailable s Traffic over -


Duration M3UA
Signaling
Links

Flow of Link(MB) MB Traffic over ([Bytes of Messages Sent]+


M3UA [Bytes of Messages
Signaling Received])/{1048576}
Links

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 578


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 16 MSCServer Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Average Load of kbit/s Traffic over ([Rate of Sending Bits (bps)]+


Link(kbps) M3UA [Rate of Receiving Bits (bps)])/
Signaling {1024}
Links

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

16.1.5 MTP3B Link Report

Report Type
Simple Report

NE Type
MSCServer

Object Type
MTP3BLink

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

MTP3B Link Sent MSUs times MTP3B -


Link Signaling
Link
Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 579


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 16 MSCServer Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Link Sent SIFSIO byte MTP3B -


Octets Signaling
Link
Measuremen
t

Link Received MSUs times MTP3B -


Signaling
Link
Measuremen
t

Link Received byte MTP3B -


SIFSIO Octets Signaling
Link
Measuremen
t

Link Congestion times MTP3B -


Times Signaling
Link
Measuremen
t

Link Congestion s MTP3B -


Duration Signaling
Link
Measuremen
t

Link Failed Duration s MTP3B -


Signaling
Link
Measuremen
t

Link Sending Used % MTP3B -


Rate Signaling
Link
Measuremen
t

Link Receiving Used % MTP3B -


Rate Signaling
Link
Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 580


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 16 MSCServer Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

16.1.6 MTP3 Link Report

Report Type
Simple Report

NE Type
MSCServer

Object Type
MTPLink

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

MTP3 Signal Units of entrie Traffic over -


Link Messages Sent s MTP
Signaling
Links

Bytes of Sent entrie Traffic over -


Messages s MTP
Signaling
Links

Signal Units of entrie Traffic over -


Messages Received s MTP
Signaling
Links

Bytes of Received entrie Traffic over -


Messages s MTP
Signaling
Links

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 581


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 16 MSCServer Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Congestion Times times Traffic over -


MTP
Signaling
Links

Congestion Duration s Traffic over -


MTP
Signaling
Links

Unavailable s Traffic over -


Duration MTP
Signaling
Links

Send Seizure Ratio % Traffic over -


MTP
Signaling
Links

Receive Seizure % Traffic over -


Ratio MTP
Signaling
Links

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

16.2 CPU Load


Report Type
Simple Report

NE Type
MSCServer

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 582


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 16 MSCServer Performance Report

Object Type
Module

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

CPU Originated Call times CPU Usage -


Load Times

Terminated Call times CPU Usage -


Times

Congestion Times times CPU Usage -

Congestion Duration s CPU Usage -

Overload Times times CPU Usage -

Overload Duration s CPU Usage -

Average Seizure % CPU Usage -


Rate

Peak Seizure Rate % CPU Usage -

Peak Seizure s CPU Usage -


Duration

BHCA none CPU Usage ({6}*[Originated Call Times]


+{4}*[Terminated Call
Times])/{10000}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

16.3 Basic MSC Service Report


Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 583


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 16 MSCServer Performance Report

NE Type
MSCServer

Object Type
MSCServer

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Device Number of VLR none Number of [Number of Local Subscribers


capabilit Registered VLR in VLR]+[Number of Roaming
y Subscriber Subscribers Subscribers in VLR]

Number of Local entrie Number of -


Subscribers in VLR s VLR
Subscribers

Number of Roaming entrie Number of -


Subscribers in VLR s VLR
Subscribers

Number of VLR none Number of [Number of Local Subscribers


Power-on Subscriber VLR in VLR]+[Number of Roaming
Subscribers Subscribers in VLR]-[Number
of IMSI Detached Subscribers
in VLR]

2G MO MO Connected Rate % GSM [Call Completion Times]/[Call


Call Subscriber Attempts]*{100}
Originated
Calls

MO Answer Rate % GSM [Answer Times]/[Call


Subscriber Attempts]*{100}
Originated
Calls

Seizure Traffic Erl GSM -


Subscriber
Originated
Calls

Call Completion Erl GSM -


Traffic Subscriber
Originated
Calls

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 584


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 16 MSCServer Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Answer Traffic Erl GSM -


Subscriber
Originated
Calls

Call Attempts times GSM -


Subscriber
Originated
Calls

Call Completion times GSM -


Times Subscriber
Originated
Calls

Answer Times times GSM -


Subscriber
Originated
Calls

2G MT MT Connected Rate % GSM [2G TERMINATED ALERT]/


Call Subscriber [2G TERMINATED CALL
Terminated ATTEMPT]*{100}
Calls

MT Answer Rate % GSM [2G TERMINATED


Subscriber ANSWER]/[2G
Terminated TERMINATED CALL
Calls ATTEMPT]*{100}

2G TERMINATED Erl GSM -


SEIZE USAGE Subscriber
Terminated
Calls

2G TERMINATED Erl GSM -


ALERT USAGE Subscriber
Terminated
Calls

2G TERMINATED Erl GSM -


ANSWER USAGE Subscriber
Terminated
Calls

2G TERMINATED times GSM -


CALL ATTEMPT Subscriber
Terminated
Calls

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 585


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 16 MSCServer Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

2G TERMINATED times GSM -


ALERT Subscriber
Terminated
Calls

2G TERMINATED times GSM -


ANSWER Subscriber
Terminated
Calls

3G MO MO Connected Rate % UTRAN [Call Completion Times]/[Call


Call Subscriber Attempts]*{100}
Originated
Calls

MO Answer Rate % UTRAN [Answer Times]/[Call


Subscriber Attempts]*{100}
Originated
Calls

Seizure Traffic Erl UTRAN -


Subscriber
Originated
Calls

Call Completion Erl UTRAN -


Traffic Subscriber
Originated
Calls

Answer Traffic Erl UTRAN -


Subscriber
Originated
Calls

Call Attempts times UTRAN -


Subscriber
Originated
Calls

Call Completion times UTRAN -


Times Subscriber
Originated
Calls

Answer Times times UTRAN -


Subscriber
Originated
Calls

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 586


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 16 MSCServer Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

3G MT MT Connected Rate % UTRAN [3G TERMINATED ALERT]/


Call Subscriber [3G TERMINATED
Terminated CALL_ATTEMPT]*{100}
Calls

MT Answer Rate % UTRAN [3G TERMINATED


Subscriber ANSWER]/[3G
Terminated TERMINATED
Calls CALL_ATTEMPT]*{100}

3G TERMINATED Erl UTRAN -


SEIZE USAGE Subscriber
Terminated
Calls

3G TERMINATED Erl UTRAN -


ALERT USAGE Subscriber
Terminated
Calls

3G TERMINATED Erl UTRAN -


ANSWER USAGE Subscriber
Terminated
Calls

3G TERMINATED times UTRAN -


CALL_ATTEMPT Subscriber
Terminated
Calls

3G TERMINATED times UTRAN -


ALERT Subscriber
Terminated
Calls

3G TERMINATED times UTRAN -


ANSWER Subscriber
Terminated
Calls

Other Incoming Connected % Incoming [Call Completion Times]/


Call Ratio Calls [Seizure Times]*{100}

Call Completion Erl Incoming -


Traffic Calls

Seizure Times times Incoming -


Calls

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 587


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 16 MSCServer Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Outgoing Connected % Outgoing [Call Completion Times]/


Ratio Calls [Seizure Attempts]*{100}

Call Completion Erl Outgoing -


Traffic Calls

Seizure Attempts times Outgoing -


Calls

ALERTING Erl Transit Calls -


TRAFFIC

SMS MO SMS Success % MSC Basic [Send SMMO Success Times]/


Ratio Services [Send SMMO Times]*{100}

MT SMS Success % MSC Basic [Receive SMMT Success


Ratio Services Times]/[Receive SMMT
Times]*{100}

Send SMMO Times times MSC Basic -


Services

Receive SMMT times MSC Basic -


Times Services

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

16.4 Trunk Group Traffic


Report Type
Simple Report

NE Type
MSCServer

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 588


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 16 MSCServer Performance Report

Object Type
Trunk Group

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Incoming Seizure Times times Incoming -


Calls through
Trunk
Groups

Call Completion times Incoming -


Times Calls through
Trunk
Groups

Answer Times times Incoming -


Calls through
Trunk
Groups

Number of Installed piece Incoming -


Circuits Calls through
Trunk
Groups

Number of Available piece Incoming -


Circuits Calls through
Trunk
Groups

Seizure Traffic Erl Incoming -


Calls through
Trunk
Groups

Call Completion Erl Incoming -


Traffic Calls through
Trunk
Groups

Answer Traffic Erl Incoming -


Calls through
Trunk
Groups

Circuit Avail Ratio % Incoming [Number of Available


Calls through Circuits]/[Number of Installed
Trunk Circuits]*{100}
Groups

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 589


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 16 MSCServer Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Average Traffic Per Erl Incoming [Seizure Traffic]/[Number of


Line Calls through Available Circuits]
Trunk
Groups

Outgoing Seizure Attempts times Outgoing -


Calls through
Trunk
Groups

Seizure Times times Outgoing -


Calls through
Trunk
Groups

Call Completion times Outgoing -


Times Calls through
Trunk
Groups

Answer Times times Outgoing -


Calls through
Trunk
Groups

Dual Seizure Times times Outgoing -


Calls through
Trunk
Groups

Number of Installed piece Outgoing -


Circuits Calls through
Trunk
Groups

Number of Available piece Outgoing -


Circuits Calls through
Trunk
Groups

Seizure Traffic Erl Outgoing -


Calls through
Trunk
Groups

Call Completion Erl Outgoing -


Traffic Calls through
Trunk
Groups

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 590


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 16 MSCServer Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Answer Traffic Erl Outgoing -


Calls through
Trunk
Groups

Circuit Avail Ratio % Outgoing [Number of Available


Calls through Circuits]/[Number of Installed
Trunk Circuits]*{100}
Groups

Average Traffic Per Erl Outgoing [Seizure Traffic]/[Number of


Line Calls through Available Circuits]
Trunk
Groups

Total Total Traffic Erl Incoming [Seizure Traffic]+[Seizure


Calls through Traffic]
Trunk
Groups

Total Traffic Per Erl Incoming [Seizure Traffic]/[Number of


Line Calls through Available Circuits]+[Seizure
Trunk Traffic]/[Number of Available
Groups Circuits]

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

16.5 Office Direction Traffic


Report Type
Simple Report

NE Type
MSCServer

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 591


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 16 MSCServer Performance Report

Object Type
Office Direction

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Incoming Number of Installed piece Incoming -


Circuits Calls in
Mobile
Office
Directions

Number of Available piece Incoming -


Circuits Calls in
Mobile
Office
Directions

Seizure Traffic Erl Incoming -


Calls in
Mobile
Office
Directions

Call Completion Erl Incoming -


Traffic Calls in
Mobile
Office
Directions

Answer Traffic Erl Incoming -


Calls in
Mobile
Office
Directions

Connected Ratio % Incoming [Call Completion Times]/


Calls in [Seizure Times]*{100}
Mobile
Office
Directions

Answer Ratio % Incoming [Answer Times]/[Seizure


Calls in Times]*{100}
Mobile
Office
Directions

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 592


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 16 MSCServer Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Seizure Times times Incoming -


Calls in
Mobile
Office
Directions

TK Avail Ratio % Incoming [Number of Available


Calls in Circuits]/[Number of Installed
Mobile Circuits]*{100}
Office
Directions

Average Traffic Per Erl Incoming [Seizure Traffic]/[Number of


Line Calls in Available Circuits]
Mobile
Office
Directions

Outgoing Number of Installed piece Outgoing -


Circuits Calls in
Mobile
Office
Directions

Number of Available piece Outgoing -


Circuits Calls in
Mobile
Office
Directions

Seizure Traffic Erl Outgoing -


Calls in
Mobile
Office
Directions

Call Completion Erl Outgoing -


Traffic Calls in
Mobile
Office
Directions

Answer Traffic Erl Outgoing -


Calls in
Mobile
Office
Directions

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 593


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 16 MSCServer Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Seizure Ratio % Outgoing [Seizure Times]/[Seizure


Calls in Attempts]*{100}
Mobile
Office
Directions

Connected Ratio % Outgoing [Call Completion Times]/


Calls in [Seizure Attempts]*{100}
Mobile
Office
Directions

Answer Ratio % Outgoing [Answer Times]/[Seizure


Calls in Attempts]*{100}
Mobile
Office
Directions

Seizure Attempts times Outgoing -


Calls in
Mobile
Office
Directions

TK Avail Ratio % Outgoing [Number of Available


Calls in Circuits]/[Number of Installed
Mobile Circuits]*{100}
Office
Directions

Average Traffic Per Erl Outgoing [Seizure Traffic]/[Number of


Line Calls in Available Circuits]
Mobile
Office
Directions

Total Total Traffic Erl Incoming [Seizure Traffic]+[Seizure


Calls in Traffic]
Mobile
Office
Directions

Total Traffic Per Erl Incoming [Seizure Traffic]/[Number of


Line Calls in Available Circuits]+[Seizure
Mobile Traffic]/[Number of Available
Office Circuits]
Directions

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 594


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 16 MSCServer Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

16.6 Mobility Management Report


Report Type
Simple Report

NE Type
MSCServer

Object Type
MSCServer

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Handove Basic Outgoing times Local MSC -


r Handover Requests Handover

Assign Assign Success Rate % GSM ([Successful Traffic Channel


Assignment Assignments]+[Successful
Traffic Channel
Assignments])/([Traffic
Channel Assignment Requests]
+[Traffic Channel Assignment
Requests])*{100}

Assign Request times GSM [Traffic Channel Assignment


Times Assignment Requests]+[Traffic Channel
Assignment Requests]

Paging Paging Success Ratio % MSC Basic [Paging Response Times]/


Services [Paging Times]*{100}

Paging Times times MSC Basic -


Services

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 595


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 16 MSCServer Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Location Location Update % Location ([Successful Location Updates


Update Success Rate Management in the VLR]+[Successful
Service Location Updates During
Roaming])/[Location Update
Requests]*{100}

Location Update times Location -


Requests Management
Service

Authenti Authentication % Authenticati [AUTH Success Times]/


cation Success Rate on [AUTH Requests]*{100}
and
Cipher AUTH Requests times Authenticati -
on

Cipher Success Rate % MSC Basic [Set Cipher Mode Success


Services Times]/[Set Cipher Mode
Times]*{100}

Set Cipher Mode times MSC Basic -


Times Services

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 596


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 17 NodeB Performance Report

17 NodeB Performance Report

About This Chapter

17.1 NodeB Report

17.2 BTS Energy Consumption Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 597


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 17 NodeB Performance Report

17.1 NodeB Report


Report Type
Simple Report

NE Type
NodeB

Object Type
Local Cell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

NodeB VS.HSUPA.Loa- times HSUPA -


Report dOutput.0 measurement
s per local
cell

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

17.2 BTS Energy Consumption Report

17.2.1 BTS Traffic and Energy Consumption Report


Report Type
Simple Report

NE Type
NodeB

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 598


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 17 NodeB Performance Report

Object Type
NodeB

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

BTS CS Traffic(Erl) none Measuremen [VS.AMR.Erlang.BestCell]


Traffic t related to
and throughput
Energy per cell
Consump
tion PS Traffic(kbit) none Measuremen ([VS.PS.Bkg.DL.8.Thruput]+
Report t related to [VS.PS.Bkg.DL.16.Thruput]+
throughput [VS.PS.Bkg.DL.32.Thruput]+
per cell [VS.PS.Bkg.DL.64.Thruput]+
[VS.PS.Bkg.DL.128.Thruput]
+[VS.PS.Bkg.DL.
144.Thruput]+
[VS.PS.Bkg.DL.256.Thruput]
+[VS.PS.Bkg.DL.
384.Thruput]+
[VS.DcchSrbKbps.Dl.Thru-
put]+
[VS.HSDPA.MeanChThrough
put.TotalBytes]*{8}+
[VS.CS.Conv.DL.
64.Thruput])/{1000}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 599


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 17 NodeB Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Total Traffic(kbit) none Measuremen ([VS.PS.Bkg.DL.8.Thruput]+


t related to [VS.PS.Bkg.DL.16.Thruput]+
throughput [VS.PS.Bkg.DL.32.Thruput]+
per cell [VS.PS.Bkg.DL.64.Thruput]+
[VS.PS.Bkg.DL.128.Thruput]
+[VS.PS.Bkg.DL.
144.Thruput]+
[VS.PS.Bkg.DL.256.Thruput]
+[VS.PS.Bkg.DL.
384.Thruput]+
[VS.DcchSrbKbps.Dl.Thru-
put]+
[VS.HSDPA.MeanChThrough
put.TotalBytes]*{8}+
[VS.CS.Conv.DL.
64.Thruput])/{1000}+
(([VS.AMR.Ctrl.DL12.2]*
{12.2}+[VS.RB.AMR.DL.
10.2]*{10.2}+
[VS.RB.AMR.DL.7.95]*
{7.95}+[VS.RB.AMR.DL.
7.4]*{7.4}+
[VS.RB.AMR.DL.6.7]*{6.7}
+[VS.RB.AMR.DL.5.9]*
{5.9}+[VS.RB.AMR.DL.
5.15]*{5.15}+
[VS.RB.AMR.DL.4.75]*
{4.75})*{0.5})

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

17.2.2 Network Energy Efficiency Indicator Report

Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 600


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 17 NodeB Performance Report

NE Type
NodeB

Object Type
NodeB

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Network EE(bit/joule) none Measuremen (([VS.PS.Bkg.DL.8.Thruput]+


Energy t related to [VS.PS.Bkg.DL.16.Thruput]+
Efficienc throughput [VS.PS.Bkg.DL.32.Thruput]+
y per cell [VS.PS.Bkg.DL.64.Thruput]+
Indicator [VS.PS.Bkg.DL.128.Thruput]
Report +[VS.PS.Bkg.DL.
144.Thruput]+
[VS.PS.Bkg.DL.256.Thruput]
+[VS.PS.Bkg.DL.
384.Thruput]+
[VS.DcchSrbKbps.Dl.Thru-
put]+
[VS.HSDPA.MeanChThrough
put.TotalBytes]*{8}+
[VS.CS.Conv.DL.
64.Thruput])/{1000}+
(([VS.AMR.Ctrl.DL12.2]*
{12.2}+[VS.RB.AMR.DL.
10.2]*{10.2}+
[VS.RB.AMR.DL.7.95]*
{7.95}+[VS.RB.AMR.DL.
7.4]*{7.4}+
[VS.RB.AMR.DL.6.7]*{6.7}
+[VS.RB.AMR.DL.5.9]*
{5.9}+[VS.RB.AMR.DL.
5.15]*{5.15}+
[VS.RB.AMR.DL.4.75]*
{4.75})*{0.5}))/
[VS.BTS.EnergyCons.Add-
ing]/{3600}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 601


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 17 NodeB Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 602


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 18 PCU Performance Report

18 PCU Performance Report

About This Chapter

18.1 Retainability Report

18.2 Transmisson Report

18.3 Accessability Report

18.4 Data Throughput Report

18.5 Availability Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 603


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 18 PCU Performance Report

18.1 Retainability Report


Report Type
Simple Report

NE Type
PCU

Object Type
Cell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Retainabi Uplink GPRS TBF % Uplink TBF ([Number of uplink TBF


lity Drop Rate(%) establishmen abnormal release due to N3101
t/release overflow (MS no response)]+
measurement [Number of uplink TBF
abnormal release due to N3103
overflow (MS no response)])/
[Number of successful uplink
TBF establishment]*{100}

Downlink GPRS % Downlink [Number of downlink TBF


TBF Drop Rate(%) TBF abnormal release due to N3105
establishmen overflow]/[Number of
t/release successful downlink TBF
measurement establishment]*{100}

Uplink EGPRS TBF % Uplink ([Number of uplink EGPRS


Drop Rate(%) EGPRS TBF TBF abnormal release due to
establishmen N3101 overflow (MS no
t/release response)]+[Number of uplink
measurement EGPRS TBF abnormal release
due to N3103 overflow (MS no
response)])/[Number of
successful uplink EGPRS TBF
establishment]*{100}

Downlink EGPRS % Downlink [Number of downlink EGPRS


TBF Drop Rate(%) EGPRS TBF TBF abnormal release due to
establishmen N3105 overflow]/[Number of
t/release successful downlink EGPRS
measurement TBF establishment]*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 604


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 18 PCU Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

18.2 Transmisson Report


Report Type
Simple Report

NE Type
PCU

Object Type
Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 605


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 18 PCU Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Transmis Retransmission Rate % Uplink RLC ({1}-(([Number of uplink RLC


son of RLC Uplink Data data data blocks using CS1]*({1}-
Block (%) transmission [Retransmission rate of RLC
measurement uplink data block using CS1
(%)]/{100}))+([Number of
uplink RLC data blocks using
CS2]*({1}-[Retransmission
rate of RLC uplink data block
using CS2(%)]/{100}))+
([Number of uplink RLC data
blocks using CS3]*({1}-
[Retransmission rate of RLC
uplink data block using CS3
(%)]/{100}))+([Number of
uplink RLC data blocks using
CS4]*({1}-[Retransmission
rate of RLC uplink data block
using CS4(%)]/{100})))/[Total
number of uplink RLC data
blocks])*{100}

Retransmission Rate % Downlink ({1}-(([Number of downlink


of RLC Downlink RLC data RLC data blocks using CS1]*
Data Block (%) transmission ({1}-[Retransmission rate of
measurement RLC downlink data block
using CS1(%)]/{100}))+
([Number of downlink RLC
data blocks using CS2]*({1}-
[Retransmission rate of RLC
downlink data block using CS2
(%)]/{100}))+([Number of
downlink RLC data blocks
using CS3]*({1}-
[Retransmission rate of RLC
downlink data block using CS3
(%)]/{100}))+([Number of
downlink RLC data blocks
using CS4]*({1}-
[Retransmission rate of RLC
downlink data block using CS4
(%)]/{100})))/[Total number
of downlink RLC data blocks])
*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 606


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 18 PCU Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Retransmission Rate % Uplink ({1}-(([Number of uplink


of Uplink EGPRS GMSK EGPRS RLC data blocks using
RLC Data Block (%) EGPRS RLC MCS1]*({1}-[Retransmission
data rate of uplink EGPRS RLC data
retransmissio block using MCS1(%)]/
n rate {100}))+([Number of uplink
measurement EGPRS RLC data blocks using
MCS2]*({1}-[Retransmission
rate of uplink EGPRS RLC data
block using MCS2(%)]/
{100}))+([Number of uplink
EGPRS RLC data blocks using
MCS3]*({1}-[Retransmission
rate of uplink EGPRS RLC data
block using MCS3(%)]/
{100}))+([Number of uplink
EGPRS RLC data blocks using
MCS4]*({1}-[Retransmission
rate of uplink EGPRS RLC data
block using MCS4(%)]/
{100}))+([Number of uplink
EGPRS RLC data blocks using
MCS5]*({1}-[Retransmission
rate of uplink EGPRS RLC data
block using MCS5(%)]/
{100}))+([Number of uplink
EGPRS RLC data blocks using
MCS6]*({1}-[Retransmission
rate of uplink EGPRS RLC data
block using MCS6(%)]/
{100}))+([Number of uplink
EGPRS RLC data blocks using
MCS7]*({1}-[Retransmission
rate of uplink EGPRS RLC data
block using MCS7(%)]/
{100}))+([Number of uplink
EGPRS RLC data blocks using
MCS8]*({1}-[Retransmission
rate of uplink EGPRS RLC data
block using MCS8(%)]/
{100}))+([Number of uplink
EGPRS RLC data blocks using
MCS9]*({1}-[Retransmission
rate of uplink EGPRS RLC data
block using MCS9(%)]/
{100})))/[Total number of

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 607


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 18 PCU Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

uplink EGPRS RLC data


blocks])*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 608


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 18 PCU Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Retransmission Rate % Downlink ({1}-(([Number of downlink


of Downlink EGPRS GMSK EGPRS RLC data blocks using
RLC Data Block (%) EGPRS RLC MCS1]*({1}-[Retransmission
data rate of downlink EGPRS RLC
retransmissio data block using MCS1(%)]/
n rate {100}))+([Number of
measurement downlink EGPRS RLC data
blocks using MCS2]*({1}-
[Retransmission rate of
downlink EGPRS RLC data
block using MCS2(%)]/
{100}))+([Number of
downlink EGPRS RLC data
blocks using MCS4]*({1}-
[Retransmission rate of
downlink EGPRS RLC data
block using MCS4(%)]/
{100}))+([Number of
downlink EGPRS RLC data
blocks using MCS4]*({1}-
[Retransmission rate of
downlink EGPRS RLC data
block using MCS4(%)]/
{100}))+([Number of
downlink EGPRS RLC data
blocks using MCS5]*({1}-
[Retransmission rate of
downlink EGPRS RLC data
block using MCS5(%)]/
{100}))+([Number of
downlink EGPRS RLC data
blocks using MCS6]*({1}-
[Retransmission rate of
downlink EGPRS RLC data
block using MCS6(%)]/
{100}))+([Number of
downlink EGPRS RLC data
blocks using MCS7]*({1}-
[Retransmission rate of
downlink EGPRS RLC data
block using MCS7(%)]/
{100}))+([Number of
downlink EGPRS RLC data
blocks using MCS8]*({1}-
[Retransmission rate of
downlink EGPRS RLC data

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 609


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 18 PCU Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

block using MCS8(%)]/


{100}))+([Number of
downlink EGPRS RLC data
blocks using MCS9]*({1}-
[Retransmission rate of
downlink EGPRS RLC data
block using MCS9(%)]/
{100})))/[Total number of
downlink EGPRS RLC data
blocks])*{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

18.3 Accessability Report


Report Type
Simple Report

NE Type
PCU

Object Type
Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 610


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 18 PCU Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Accessab Uplink Assignment % Uplink TBF ([Number of successful uplink


ility Success Rate(%) establishmen TBF establishment]/[Number
t/release of uplink TBF establishment
measurement attempts])*{100}

Downlink % Downlink ([Number of successful


Assignment Success TBF downlink TBF establishment]/
Rate(%) establishmen [Number of downlink TBF
t/release establishment attempts])*
measurement {100}

Mean Inter-arrival s Packet access {GP}*{60}/[Number of packet


Time of Packet performance channel requests received on
Access Requests on measurement CCCH]
CCCH(s) on CCCH

Uplink GPRS TBF % Uplink TBF [Number of uplink TBF


Congestion Rate(%) establishmen establishment failures due to no
t/release channel]/[Number of uplink
measurement TBF establishment attempts]*
{100}

Downlink GPRS % Downlink [Number of downlink TBF


TBF Congestion TBF establishment failures due to no
Rate(%) establishmen channel]/[Number of downlink
t/release TBF establishment attempts]*
measurement {100}

Uplink GPRS TBF % Uplink [Number of uplink EGPRS


Congestion Rate(%) EGPRS TBF TBF establishment failures due
establishmen to no channel]/[Number of
t/release uplink EGPRS TBF
measurement establishment attempts]*{100}

Downlink GPRS % Downlink [Number of downlink EGPRS


TBF Congestion EGPRS TBF TBF establishment failures due
Rate(%) establishmen to no channel]/[Number of
t/release downlink EGPRS TBF
measurement establishment attempts]*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 611


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 18 PCU Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

18.4 Data Throughput Report


Report Type
Simple Report

NE Type
PCU

Object Type
PCU

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Data Uplink RLC Payload kilobi Uplink RLC ([Number of uplink RLC data
Through ( kbits ) ts data blocks using CS1]*{23}+
put transmission [Number of uplink RLC data
measurement blocks using CS2]*{34}+
[Number of uplink RLC data
blocks using CS3]*{40}+
[Number of uplink RLC data
blocks using CS4]*{54})*{8}/
{1024}

Downlink RLC kilobi Downlink ([Number of downlink RLC


Payload( kbits ) ts RLC data data blocks using CS1]*{23}+
transmission [Number of downlink RLC
measurement data blocks using CS2]*{34}+
[Number of downlink RLC
data blocks using CS3]*{40}+
[Number of downlink RLC
data blocks using CS4]*{54})*
{8}/{1024}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 612


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 18 PCU Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Uplink EDGPRS kilobi Uplink ([Number of uplink EGPRS


RLC Payload( kbits ) ts GMSK RLC data blocks using MCS1]
EGPRS RLC *{22}+[Number of uplink
data EGPRS RLC data blocks using
retransmissio MCS2]*{28}+[Number of
n rate uplink EGPRS RLC data
measurement blocks using MCS3]*{37}+
[Number of uplink EGPRS
RLC data blocks using MCS4]
*{44}+[Number of uplink
EGPRS RLC data blocks using
MCS5]*{56}+[Number of
uplink EGPRS RLC data
blocks using MCS6]*{74}+
[Number of uplink EGPRS
RLC data blocks using MCS7]
*{56}+[Number of uplink
EGPRS RLC data blocks using
MCS8]*{68}+[Number of
uplink EGPRS RLC data
blocks using MCS9]*{74})*
{8}/{1024}

Downlink EDGPRS kilobi Downlink ([Number of downlink EGPRS


RLC Payload( kbits ) ts GMSK RLC data blocks using MCS1]
EGPRS RLC *{22}+[Number of downlink
data EGPRS RLC data blocks using
retransmissio MCS2]*{28}+[Number of
n rate downlink EGPRS RLC data
measurement blocks using MCS3]*{37}+
[Number of downlink EGPRS
RLC data blocks using MCS4]
*{44}+[Number of downlink
EGPRS RLC data blocks using
MCS5]*{56}+[Number of
downlink EGPRS RLC data
blocks using MCS6]*{74}+
[Number of downlink EGPRS
RLC data blocks using MCS7]
*{56}+[Number of downlink
EGPRS RLC data blocks using
MCS8]*{68}+[Number of
downlink EGPRS RLC data
blocks using MCS9]*{74})*
{8}/{1024}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 613


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 18 PCU Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Mean Payload kiloby Uplink LLC [Total bytes of uplink


(kbytes) of the tes data LLC_PDUs sent]*{8}/{1024}
Downlink Data at the transmission
LLC Layer measurement

Mean Payload kiloby Downlink [Total bytes of LLC_PDUs


(kbytes) of the tes LLC data sent]*{8}/{1024}
Uplink Data at the transmission
LLC Layer measurement

Mean Downlink kbit/s NS [Total bytes of NS PDUs sent


NS_PDUs transmission by NS sublayer]*{8}/({1024}*
Throughput(kbits/s) performance {GP}*{60})
measurement

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 614


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 18 PCU Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Packet Data Rate on % Uplink RLC (((([Number of uplink RLC


Air Interface(UL / data data blocks using CS1]*{23}+
DL) transmission [Number of uplink RLC data
measurement blocks using CS2]*{34}+
[Number of uplink RLC data
blocks using CS3]*{40}+
[Number of uplink RLC data
blocks using CS4]*{54})*{8}/
{1024})+(([Number of uplink
EGPRS RLC data blocks using
MCS1]*{22}+[Number of
uplink EGPRS RLC data
blocks using MCS2]*{28}+
[Number of uplink EGPRS
RLC data blocks using MCS3]
*{37}+[Number of uplink
EGPRS RLC data blocks using
MCS4]*{44}+[Number of
uplink EGPRS RLC data
blocks using MCS5]*{56}+
[Number of uplink EGPRS
RLC data blocks using MCS6]
*{74}+[Number of uplink
EGPRS RLC data blocks using
MCS7]*{56}+[Number of
uplink EGPRS RLC data
blocks using MCS8]*{68}+
[Number of uplink EGPRS
RLC data blocks using MCS9]
*{74})*{8}/{1024}))/
((([Number of downlink RLC
data blocks using CS1]*{23}+
[Number of downlink RLC
data blocks using CS2]*{34}+
[Number of downlink RLC
data blocks using CS3]*{40}+
[Number of downlink RLC
data blocks using CS4]*{54})*
{8}/{1024})+(([Number of
downlink EGPRS RLC data
blocks using MCS1]*{22}+
[Number of downlink EGPRS
RLC data blocks using MCS2]
*{28}+[Number of downlink
EGPRS RLC data blocks using
MCS3]*{37}+[Number of
downlink EGPRS RLC data

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 615


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 18 PCU Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

blocks using MCS4]*{44}+


[Number of downlink EGPRS
RLC data blocks using MCS5]
*{56}+[Number of downlink
EGPRS RLC data blocks using
MCS6]*{74}+[Number of
downlink EGPRS RLC data
blocks using MCS7]*{56}+
[Number of downlink EGPRS
RLC data blocks using MCS8]
*{68}+[Number of downlink
EGPRS RLC data blocks using
MCS9]*{74})*{8}/{1024})))
*{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

18.5 Availability Report


Report Type
Simple Report

NE Type
PCU

Object Type
Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 616


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 18 PCU Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Availabil Uplink PDTCH/ % Cell radio [Number of RLC data blocks


ity PACCH Utilization channel received on uplink PDTCH/
Rate(%) performance PACCH]*{100}/([Number of
measurement RLC data blocks received on
uplink PDTCH/PACCH]*
{100}/[Uplink PDTCH/
PACCH utilization rate(%)])

Downlink PDTCH/ % Cell radio [Number of RLC data blocks


PACCH Utilization channel received on downlink PDTCH/
Rate(%) performance PACCH]*{100}/([Number of
measurement RLC data blocks received on
downlink PDTCH/PACCH]*
{100}/[Downlink PDTCH/
PACCH utilization rate(%)])

PDCH Occupation % PDCH [Mean number of occupied


Rate(%) resource PDCHs]*{100}/[Mean
performance number of actived GPRS
measurement PDCHs]

Pre-empted Dynamic % PDCH [Number of pre-empted


PDCH Carrying resource PDCHs carrying packet traffic]
Packet Traffic performance *{100}/[Number of dynamic
Reclaimed Success measurement PDCHs reclaimed by BSC]
Rate(%)

PDCH Allocation % Uplink TBF ({1}-([Number of uplink TBF


Success Rate(%) establishmen establishment failures due to
t/release MS no response]+[Number of
measurement downlink TBF establishment
failures due to MS no
response])/([Number of uplink
TBF establishment attempts]+
[Number of downlink TBF
establishment attempts]))

Downlink RLC Data kbit/s PDCH [Number of GPRS PDCHs


Throughput per resource occupied by downlink TBF]/
PDCH performance ({GP}*{12})
measurement

Uplink RLC Data kbit/s PDCH [Number of PDCHs occupied


Throughput per resource by uplink TBF]/({GP}*{12})
PDCH performance
measurement

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 617


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 18 PCU Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 618


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 19 UMTS RAN NHC Report

19 UMTS RAN NHC Report

About This Chapter

19.1 Cell Performance Measurement(Morning Busy Time)

19.2 Cell Performance Measurement(Night Busy Time)

19.3 High Call Drop Rate Cell(Morning Busy Time)

19.4 High Call Drop Rate Cell(Night Busy Time)

19.5 No Services Cell(Morning Busy Time)

19.6 No Services Cell(Night Busy Time)

19.7 Performance Check Gather Page

19.8 Traffic Volume Measurement

19.9 UL Interference Cell(Morning Busy Time)

19.10 UL Interference Cell(Night Busy Time)

19.11 Unavailable Cell(Morning Busy Time)

19.12 Unavailable Cell(Night Busy Time)

19.13 Worst Cell(Morning Busy Time)

19.14 Worst Cell(Night Busy Time)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 619


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 19 UMTS RAN NHC Report

19.1 Cell Performance Measurement(Morning Busy Time)


Report Type
Simple Report

NE Type
RNC

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Cell CS Erlang % Traffic [VS.CSLoad.Erlang.Equiv.RN


Performa Measuremen C]
nce t per RNC
Measure
ment

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 620


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 19 UMTS RAN NHC Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Connection Setup % RRC (([VS.RRC.SuccConnEstab.O


Success Rate(CS) connection rgConv]+
setup [VS.RRC.SuccConnEstab.Org
measurement Subs]+
per RNC [VS.RRC.SuccConnEstab.Tr
mConv]+
[VS.RRC.SuccConnEstab.Res
t]+
[VS.RRC.SuccConnEstab.Em
g]+
[VS.RRC.SuccConnEstab.Un-
known])*
(([RAB.SuccEstabCSNoQueui
ng.Conv]+
[RAB.SuccEstabCSNoQueuin
g.Strm]+
[RAB.SuccEstabCSQueuing.
Conv]+
[RAB.SuccEstabCSQueuing.S
trm])))/
((([VS.RRC.AttConnEstab.Or
gConv]+
[VS.RRC.AttConnEstab.Org-
Subs]+
[VS.RRC.AttConnEstab.Trm
Conv]+
[VS.RRC.AttConnEstab.Rest]
+
[VS.RRC.AttConnEstab.Emg]
+[VS.RRC.AttConnEstab.Un-
known]))*
([RAB.AttEstabCS.Conv]))*
{100}

Drop Rate(CS) % Measuremen ([VS.RAB.Loss.CS.Abnorm.R


t of RAB NC]+
release [VS.RAB.Loss.CS.RF.RNC])/
triggered by ([RAB.SuccEstabCSNoQueui
UTRAN per ng.Conv]+
RNC [RAB.SuccEstabCSNoQueuin
g.Strm]+
[RAB.SuccEstabCSQueuing.
Conv]+
[RAB.SuccEstabCSQueuing.S
trm])*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 621


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 19 UMTS RAN NHC Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

PS Erlang % Traffic [VS.PSLoad.ULThruput.RNC


Measuremen ]+
t per RNC [VS.PSLoad.DLThruput.RNC
]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 622


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 19 UMTS RAN NHC Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

RRC Connection % RRC ((([VS.RRC.SuccConnEstab.


Setup Success Rate connection OrgInt]+
(PS) setup [VS.RRC.SuccConnEstab.Org
measurement Bkg]+
per RNC [VS.RRC.SuccConnEstab.Tr
mInt]+
[VS.RRC.SuccConnEstab.Tr
mBkg]+
[VS.RRC.SuccConnEstab.Org
HPSi]+
[VS.RRC.SuccConnEstab.Tm
HPSi])*
([VS.RRC.AttConnEstab.Or-
gInt]+
[VS.RRC.AttConnEstab.OrgB
kg]+
[VS.RRC.AttConnEstab.TrmI
nt]+
[VS.RRC.AttConnEstab.Trm
Bkg]+
[VS.RRC.AttConnEstab.OrgH
PSig]+
[VS.RRC.AttConnEstab.TmH
PSig])))/
(([RAB.SuccEstabPSNoQueui
ng.Conv]+
[RAB.SuccEstabPSNoQueuin
g.Strm]+
[RAB.SuccEstabPSNoQueuin
g.Intact]+
[RAB.SuccEstabPSNoQueuin
g.Bgrd]+
[RAB.SuccEstabPSNoQueuin
g.Conv]+
[RAB.SuccEstabPSQueuing.S
trm]+
[RAB.SuccEstabPSQueuing.I
ntact]+
[RAB.SuccEstabPSQueuing.B
grd])*
([VS.RAB.AttEstabPS.Conv]
+[RAB.AttEstabPS.Strm]+
[RAB.AttEstabPS.Intact]+
[RAB.AttEstabPS.Bgrd]))*
{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 623


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 19 UMTS RAN NHC Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Drop Rate(PS) % Measuremen ([VS.RAB.Loss.PS.Abnorm.R


t of RAB NC]+
release [VS.RAB.Loss.PS.RF.RNC])/
triggered by ([RAB.SuccEstabPSNoQueui
UTRAN per ng.Conv]+
RNC [RAB.SuccEstabPSNoQueuin
g.Strm]+
[RAB.SuccEstabPSNoQueuin
g.Intact]+
[RAB.SuccEstabPSNoQueuin
g.Bgrd]+
[RAB.SuccEstabPSQueuing.C
onv]+
[RAB.SuccEstabPSQueuing.S
trm]+
[RAB.SuccEstabPSQueuing.I
ntact]+
[RAB.SuccEstabPSQueuing.B
grd])*{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

19.2 Cell Performance Measurement(Night Busy Time)


Report Type
Simple Report

NE Type
RNC

Object Type
RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 624


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 19 UMTS RAN NHC Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Cell CS Erlang % Traffic [VS.CSLoad.Erlang.Equiv.RN


Performa Measuremen C]
nce t per RNC
Measure
ment Connection Setup % RRC (([VS.RRC.SuccConnEstab.O
Success Rate(CS) connection rgConv]+
setup [VS.RRC.SuccConnEstab.Org
measurement Subs]+
per RNC [VS.RRC.SuccConnEstab.Tr
mConv]+
[VS.RRC.SuccConnEstab.Res
t]+
[VS.RRC.SuccConnEstab.Em
g]+
[VS.RRC.SuccConnEstab.Un-
known])*
(([RAB.SuccEstabCSNoQueui
ng.Conv]+
[RAB.SuccEstabCSNoQueuin
g.Strm]+
[RAB.SuccEstabCSQueuing.
Conv]+
[RAB.SuccEstabCSQueuing.S
trm])))/
((([VS.RRC.AttConnEstab.Or
gConv]+
[VS.RRC.AttConnEstab.Org-
Subs]+
[VS.RRC.AttConnEstab.Trm
Conv]+
[VS.RRC.AttConnEstab.Rest]
+
[VS.RRC.AttConnEstab.Emg]
+[VS.RRC.AttConnEstab.Un-
known]))*
([RAB.AttEstabCS.Conv]))*
{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 625


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 19 UMTS RAN NHC Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Drop Rate(CS) % Measuremen ([VS.RAB.Loss.CS.Abnorm.R


t of RAB NC]+
release [VS.RAB.Loss.CS.RF.RNC])/
triggered by ([RAB.SuccEstabCSNoQueui
UTRAN per ng.Conv]+
RNC [RAB.SuccEstabCSNoQueuin
g.Strm]+
[RAB.SuccEstabCSQueuing.
Conv]+
[RAB.SuccEstabCSQueuing.S
trm])*{100}

PS Erlang % Traffic [VS.PSLoad.ULThruput.RNC


Measuremen ]+
t per RNC [VS.PSLoad.DLThruput.RNC
]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 626


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 19 UMTS RAN NHC Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

RRC Connection % RRC ((([VS.RRC.SuccConnEstab.


Setup Success Rate connection OrgInt]+
(PS) setup [VS.RRC.SuccConnEstab.Org
measurement Bkg]+
per RNC [VS.RRC.SuccConnEstab.Tr
mInt]+
[VS.RRC.SuccConnEstab.Tr
mBkg]+
[VS.RRC.SuccConnEstab.Org
HPSi]+
[VS.RRC.SuccConnEstab.Tm
HPSi])*
([VS.RRC.AttConnEstab.Or-
gInt]+
[VS.RRC.AttConnEstab.OrgB
kg]+
[VS.RRC.AttConnEstab.TrmI
nt]+
[VS.RRC.AttConnEstab.Trm
Bkg]+
[VS.RRC.AttConnEstab.OrgH
PSig]+
[VS.RRC.AttConnEstab.TmH
PSig])))/
(([RAB.SuccEstabPSNoQueui
ng.Conv]+
[RAB.SuccEstabPSNoQueuin
g.Strm]+
[RAB.SuccEstabPSNoQueuin
g.Intact]+
[RAB.SuccEstabPSNoQueuin
g.Bgrd]+
[RAB.SuccEstabPSNoQueuin
g.Conv]+
[RAB.SuccEstabPSQueuing.S
trm]+
[RAB.SuccEstabPSQueuing.I
ntact]+
[RAB.SuccEstabPSQueuing.B
grd])*
([VS.RAB.AttEstabPS.Conv]
+[RAB.AttEstabPS.Strm]+
[RAB.AttEstabPS.Intact]+
[RAB.AttEstabPS.Bgrd]))*
{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 627


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 19 UMTS RAN NHC Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Drop Rate(PS) % Measuremen ([VS.RAB.Loss.PS.Abnorm.R


t of RAB NC]+
release [VS.RAB.Loss.PS.RF.RNC])/
triggered by ([RAB.SuccEstabPSNoQueui
UTRAN per ng.Conv]+
RNC [RAB.SuccEstabPSNoQueuin
g.Strm]+
[RAB.SuccEstabPSNoQueuin
g.Intact]+
[RAB.SuccEstabPSNoQueuin
g.Bgrd]+
[RAB.SuccEstabPSQueuing.C
onv]+
[RAB.SuccEstabPSQueuing.S
trm]+
[RAB.SuccEstabPSQueuing.I
ntact]+
[RAB.SuccEstabPSQueuing.B
grd])*{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

19.3 High Call Drop Rate Cell(Morning Busy Time)


Report Type
Simple Report

NE Type
RNC

Object Type
UCell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 628


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 19 UMTS RAN NHC Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

High Call Cell Drop Rate(CS) % Measuremen ([VS.RAB.Loss.CS.Abnorm]+


Drop t of RAB [VS.RAB.Loss.CS.RF])/
Rate Cell release ([VS.RAB.Loss.CS.RF]+
triggered by [VS.RAB.Loss.CS.Abnorm]+
UTRAN per [VS.RAB.Loss.CS.Norm])*
cell {100}

Cell Drop Rate(PS) % Measuremen ([VS.RAB.Loss.PS.RF]+


t of RAB [VS.RAB.Loss.PS.Abnorm])/
release ([VS.RAB.Loss.PS.RF]+
triggered by [VS.RAB.Loss.PS.Abnorm]+
UTRAN per [VS.RAB.Loss.PS.Norm])*
cell {100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

19.4 High Call Drop Rate Cell(Night Busy Time)


Report Type
Simple Report

NE Type
RNC

Object Type
UCell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 629


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 19 UMTS RAN NHC Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

High Call Cell Drop Rate(CS) % Measuremen ([VS.RAB.Loss.CS.Abnorm]+


Drop t of RAB [VS.RAB.Loss.CS.RF])/
Rate Cell release ([VS.RAB.Loss.CS.RF]+
triggered by [VS.RAB.Loss.CS.Abnorm]+
UTRAN per [VS.RAB.Loss.CS.Norm])*
cell {100}

Cell Drop Rate(PS) % Measuremen ([VS.RAB.Loss.PS.RF]+


t of RAB [VS.RAB.Loss.PS.Abnorm])/
release ([VS.RAB.Loss.PS.RF]+
triggered by [VS.RAB.Loss.PS.Abnorm]+
UTRAN per [VS.RAB.Loss.PS.Norm])*
cell {100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

19.5 No Services Cell(Morning Busy Time)


Report Type
Simple Report

NE Type
RNC

Object Type
UCell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 630


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 19 UMTS RAN NHC Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

No RABSetupSucc % Measuremen (([VS.RAB.SuccEstabCS.Con


Services (Cell) t of PS RAB v]+
Cell assignment [VS.RAB.SuccEstabCS.Str])/
setup per cell ([VS.RAB.AttEstabCS.Conv]
+[VS.RAB.AttEstabCS.Str])*
{100})+
(([VS.RAB.SuccEstabPS.Con
v]+
[VS.RAB.SuccEstabPS.Str]+
[VS.RAB.SuccEstabPS.Inter]
+
[VS.RAB.SuccEstabPS.Bkg])/
([VS.RAB.AttEstabPS.Conv]
+[VS.RAB.AttEstabPS.Str]+
[VS.RAB.AttEstabPS.Inter]+
[VS.RAB.AttEstabPS.Bkg])*
{100})

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

19.6 No Services Cell(Night Busy Time)


Report Type
Simple Report

NE Type
RNC

Object Type
UCell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 631


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 19 UMTS RAN NHC Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

No RABSetupSucc % Measuremen (([VS.RAB.SuccEstabCS.Con


Services (Cell) t of PS RAB v]+
Cell assignment [VS.RAB.SuccEstabCS.Str])/
setup per cell ([VS.RAB.AttEstabCS.Conv]
+[VS.RAB.AttEstabCS.Str])*
{100})+
(([VS.RAB.SuccEstabPS.Con
v]+
[VS.RAB.SuccEstabPS.Str]+
[VS.RAB.SuccEstabPS.Inter]
+
[VS.RAB.SuccEstabPS.Bkg])/
([VS.RAB.AttEstabPS.Conv]
+[VS.RAB.AttEstabPS.Str]+
[VS.RAB.AttEstabPS.Inter]+
[VS.RAB.AttEstabPS.Bkg])*
{100})

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

19.7 Performance Check Gather Page


Report Type
Simple Report

NE Type
RNC

Object Type
RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 632


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 19 UMTS RAN NHC Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Page HS-DSCH to DCH % HSDPA [VS.HSDPA.ChR.HSDSCHto


Handover Success Measuremen DCH]/
Rate(>95%) t per cell [VS.HSDPA.ChR.HSDSCHto
DCH.Att]*{100}

DCH to HS-DSCH % HSDPA [VS.HSDPA.ChR.DCHtoHSD


Handover Success Measuremen SCH]/
Rate(>95%) t per cell [VS.HSDPA.ChR.DCHtoHSD
SCH.Att]*{100}

HS-DSCH Service % HSDPA [VS.HSDPA.HHO.SuccOu-


Cell Change Success Measuremen tIntraFreq]/
Rate(with Intra t per cell [VS.HSDPA.HHO.AttOutIn-
HHO)(>95%) traFreq]*{100}

HS-DSCH Service % HSDPA [VS.HSDPA.HHO.SuccOu-


Cell Change Success Measuremen tInterFreq]/
Rate(with Inter t per cell [VS.HSDPA.HHO.AttOutIn-
HHO)(>95%) terFreq]*{100}

HSDPA RAB Setup % HSDPA [VS.HSDPA.RAB.SuccEs-


Success Rate(>95%) Measuremen tab]/([VS.HSDPA.RAB.At-
t per cell tEstab]*[VS.HSDPA.RAB.At-
tEstab])*{100}

HS-DSCH Service % HSDPA [VS.HSDPA.SHO.CellChg.Su


Cell Change Success Measuremen ccOut]/
Rate with SHO t per cell [VS.HSDPA.SHO.CellChg.At
(HSDPA to HSDPA) tOut]*{100}
(>95%)

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 633


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 19 UMTS RAN NHC Report

19.8 Traffic Volume Measurement


Report Type
Simple Report

NE Type
RNC

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Traffic CS Erlang % Traffic [VS.CSLoad.Erlang.Equiv.RN


Volume Measuremen C]
Measure t per RNC
ment
PS Erlang % Traffic [VS.PSLoad.ULThruput.RNC
Measuremen ]+
t per RNC [VS.PSLoad.DLThruput.RNC
]

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

19.9 UL Interference Cell(Morning Busy Time)


Report Type
Simple Report

NE Type
RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 634


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 19 UMTS RAN NHC Report

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

UL VS.MinRTWP % Cell TX and [VS.MinRTWP]


Interfere RX Power
nce Cell Measuremen
t per cell

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

19.10 UL Interference Cell(Night Busy Time)


Report Type
Simple Report

NE Type
RNC

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

UL VS.MinRTWP % Cell TX and [VS.MinRTWP]


Interfere RX Power
nce Cell Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 635


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 19 UMTS RAN NHC Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

19.11 Unavailable Cell(Morning Busy Time)


Report Type
Simple Report

NE Type
RNC

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Unavaila VS.Cell.UnavailTim % Measuremen [VS.Cell.UnavailTime.OM]


ble Cell e.OM t related to
Algorithm
per cell

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 636


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 19 UMTS RAN NHC Report

19.12 Unavailable Cell(Night Busy Time)


Report Type
Simple Report

NE Type
RNC

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Unavaila VS.Cell.UnavailTim % Measuremen [VS.Cell.UnavailTime.OM]


ble Cell e.OM t related to
Algorithm
per cell

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

19.13 Worst Cell(Morning Busy Time)


Report Type
Simple Report

NE Type
RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 637


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 19 UMTS RAN NHC Report

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Worst VS Setup Success % Measuremen [VS.RAB.SuccEstab.AMR]/


Cell Ratio t of CS RAB [VS.RAB.AttEstab.AMR]*
(Morning assignment {100}
Busy setup per cell
Time)
VS RAB Setup % Measuremen [VS.RAB.SuccEstCS.Conv.
Success Ratio t of CS RAB 64]/[VS.RAB.AttEstCS.Conv.
assignment 64]*{100}
setup per cell

VS Call Drop Ratio % Measuremen [VS.RAB.Loss.CS.AMR]/


t of RAB ([VS.RAB.Loss.CS.AMR]+
release [VS.RAB.Loss.CS.Norm.AM
triggered by R])*{100}
UTRAN per
cell

VP Call Drop Ratio % Measuremen [VS.RAB.Loss.CS.Conv64K]/


(cell) t of RAB ([VS.RAB.Loss.CS.Norm]-
release [VS.RAB.Loss.CS.Norm.AM
triggered by R]+
UTRAN per [VS.RAB.Loss.CS.Conv64K])
cell *{100}

VS.Filter Condtion % Measuremen ([VS.RAB.SuccEstab.AMR]/


(Worst Cell) t of RAB [VS.RAB.AttEstab.AMR]*
release {100})+({4}*
triggered by ([VS.RAB.SuccEstab.AMR]/
UTRAN per [VS.RAB.AttEstab.AMR]*
cell {100}))

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 638


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 19 UMTS RAN NHC Report

19.14 Worst Cell(Night Busy Time)


Report Type
Simple Report

NE Type
RNC

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Worst VS Setup Success % Measuremen [VS.RAB.SuccEstab.AMR]/


Cell Ratio t of CS RAB [VS.RAB.AttEstab.AMR]*
(Night assignment {100}
Busy setup per cell
Time)
VS RAB Setup % Measuremen [VS.RAB.SuccEstCS.Conv.
Success Ratio t of CS RAB 64]/[VS.RAB.AttEstCS.Conv.
assignment 64]*{100}
setup per cell

VS Call Drop Ratio % Measuremen [VS.RAB.Loss.CS.AMR]/


t of RAB ([VS.RAB.Loss.CS.AMR]+
release [VS.RAB.Loss.CS.Norm.AM
triggered by R])*{100}
UTRAN per
cell

VP Call Drop Ratio % Measuremen [VS.RAB.Loss.CS.Conv64K]/


(cell) t of RAB ([VS.RAB.Loss.CS.Norm]-
release [VS.RAB.Loss.CS.Norm.AM
triggered by R]+
UTRAN per [VS.RAB.Loss.CS.Conv64K])
cell *{100}

VS.Filter Condtion % Measuremen ([VS.RAB.SuccEstab.AMR]/


(Worst Cell) t of RAB [VS.RAB.AttEstab.AMR]*
release {100})+({4}*
triggered by ([VS.RAB.SuccEstab.AMR]/
UTRAN per [VS.RAB.AttEstab.AMR]*
cell {100}))

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 639


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 19 UMTS RAN NHC Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 640


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

20 UMTS RAN Performance Report

About This Chapter

20.1 Cell Reports

20.2 Coverage Evaluation Reports

20.3 RNC Reports

20.4 Troubleshooting Reports

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 641


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

20.1 Cell Reports

20.1.1 Accessibility Report

Report Type
Simple Report

NE Type
RNC

Object Type
UCell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 642


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Accessib Radio Access % RRC (([RRC.SuccConnEstab.Og-


ility Success Ratio connection ConvCall]+
setup [RRC.SuccConnEstab.OrgStr-
measurement Call]+
per cell [RRC.SuccConnEstab.OrgItr-
Call]+
[RRC.SuccConnEstab.OrgBk
gCall]+
[RRC.SuccConnEstab.Org-
SubCall]+
[RRC.SuccConnEstab.TmCon
vCall]+
[RRC.SuccConnEstab.TmStr
Call]+
[RRC.SuccConnEstab.TmItr-
Call]+
[RRC.SuccConnEstab.TmBkg
Call]+
[RRC.SuccConnEstab.Emg-
Call]+
[RRC.SuccConnEstab.Un-
kown]+
[RRC.SuccConnEstab.OgHhP
rSig]+
[RRC.SuccConnEstab.OgLwP
rSig]+
[RRC.SuccConnEstab.CallRe-
Est]+
[RRC.SuccConnEstab.TmHhP
rSig]+
[RRC.SuccConnEstab.TmLw
PrSig])/
([RRC.AttConnEstab.Org-
ConvCall]+
[RRC.AttConnEstab.OrgStr-
Call]+
[RRC.AttConnEstab.OrgInter-
Call]+
[RRC.AttConnEstab.OrgBkg-
Call]+
[RRC.AttConnEstab.OgSub-
Call]+
[RRC.AttConnEstab.TmConv
Call]+
[RRC.AttConnEstab.TmStrCa

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 643


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

ll]+
[RRC.AttConnEstab.TmInter-
Call]+
[RRC.AttConnEstab.TmBkgC
all]+
[RRC.AttConnEstab.Emg-
Call]+
[RRC.AttConnEstab.Un-
known]+
[RRC.AttConnEstab.OgHhPr-
Sig]+
[RRC.AttConnEstab.OgLwPr-
Sig]+
[RRC.AttConnEstab.CallRe-
Est]+
[RRC.AttConnEstab.TmHhPr
Sig]+
[RRC.AttConnEstab.TmLwPr
Sig])*{100})*
(([VS.RAB.SuccEstabCS.Con
v]+
[VS.RAB.SuccEstabCS.Str])+
([VS.RAB.SuccEstabPS.Conv
]+[VS.RAB.SuccEstabPS.Str]
+[VS.RAB.SuccEstabPS.In-
ter]+
[VS.RAB.SuccEstabPS.Bkg]))
/
(([VS.RAB.AttEstabCS.Conv]
+[VS.RAB.AttEstabCS.Str])+
([VS.RAB.AttEstabPS.Conv]
+[VS.RAB.AttEstabPS.Str]+
[VS.RAB.AttEstabPS.Inter]+
[VS.RAB.AttEstabPS.Bkg]))

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 644


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

RRC Setup Success % RRC ([RRC.SuccConnEstab.IRAT-


Ratio(other) connection CelRes]+
setup [RRC.SuccConnEstab.IRATC
measurement CO]+
per cell [RRC.SuccConnEstab.Reg]+
[RRC.SuccConnEstab.De-
tach])/
([RRC.AttConnEstab.IRAT-
CelRes]+
[RRC.AttConnEstab.IRATC-
CO]+
[RRC.AttConnEstab.Reg]+
[RRC.AttConnEstab.Detach])
*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 645


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

RRC Setup Success % RRC ([RRC.SuccConnEstab.Og-


Ratio(service) connection ConvCall]+
setup [RRC.SuccConnEstab.OrgStr-
measurement Call]+
per cell [RRC.SuccConnEstab.OrgItr-
Call]+
[RRC.SuccConnEstab.OrgBk
gCall]+
[RRC.SuccConnEstab.Org-
SubCall]+
[RRC.SuccConnEstab.TmCon
vCall]+
[RRC.SuccConnEstab.TmStr
Call]+
[RRC.SuccConnEstab.TmItr-
Call]+
[RRC.SuccConnEstab.TmBkg
Call]+
[RRC.SuccConnEstab.Emg-
Call]+
[RRC.SuccConnEstab.Un-
kown]+
[RRC.SuccConnEstab.OgHhP
rSig]+
[RRC.SuccConnEstab.OgLwP
rSig]+
[RRC.SuccConnEstab.CallRe-
Est]+
[RRC.SuccConnEstab.TmHhP
rSig]+
[RRC.SuccConnEstab.TmLw
PrSig])/
([RRC.AttConnEstab.Org-
ConvCall]+
[RRC.AttConnEstab.OrgStr-
Call]+
[RRC.AttConnEstab.OrgInter-
Call]+
[RRC.AttConnEstab.OrgBkg-
Call]+
[RRC.AttConnEstab.OgSub-
Call]+
[RRC.AttConnEstab.TmConv
Call]+
[RRC.AttConnEstab.TmStrCa
ll]+
[RRC.AttConnEstab.TmInter-

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 646


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Call]+
[RRC.AttConnEstab.TmBkgC
all]+
[RRC.AttConnEstab.Emg-
Call]+
[RRC.AttConnEstab.Un-
known]+
[RRC.AttConnEstab.OgHhPr-
Sig]+
[RRC.AttConnEstab.OgLwPr-
Sig]+
[RRC.AttConnEstab.CallRe-
Est]+
[RRC.AttConnEstab.TmHhPr
Sig]+
[RRC.AttConnEstab.TmLwPr
Sig])*{100}

AMR RAB Setup % Measuremen [VS.RAB.SuccEstab.AMR]/


Success Ratio t of CS RAB [VS.RAB.AttEstab.AMR]*
assignment {100}
setup per cell

VP RAB Setup % Measuremen [VS.RAB.SuccEstCS.Conv.


Success Ratio t of CS RAB 64]/[VS.RAB.AttEstCS.Conv.
assignment 64]*{100}
setup per cell

PS RAB Setup % Measuremen ([VS.RAB.SuccEstabPS.Conv


Success Ratio t of PS RAB ]+[VS.RAB.SuccEstabPS.Str]
assignment +[VS.RAB.SuccEstabPS.In-
setup per cell ter]+
[VS.RAB.SuccEstabPS.Bkg])/
([VS.RAB.AttEstabPS.Conv]
+[VS.RAB.AttEstabPS.Str]+
[VS.RAB.AttEstabPS.Inter]+
[VS.RAB.AttEstabPS.Bkg])*
{100}

HSDPA RAB Setup % HSDPA [VS.HSDPA.RAB.SuccEs-


Success Ratio Measuremen tab]/[VS.HSDPA.RAB.AttEs-
t per cell tab]*{100}

HSUPA RAB Setup % HSUPA [VS.HSUPA.RAB.SuccEs-


Success Ratio Measuremen tab]/[VS.HSUPA.RAB.AttEs-
t per cell tab]*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 647


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

20.1.2 Mobility Report

Report Type
Simple Report

NE Type
RNC

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Mobility Soft Handover % Soft ([SHO.SuccRLAddUESide]+


Success Ratio(Cell) Handover [SHO.SuccRLDelUESide])/
Measuremen ([SHO.AttRLAddUESide]+
t per cell [SHO.AttRLDelUESide])*
{100}

HS-DSCH Service % HSDPA [VS.HSDPA.SHO.CellChg.Su


Cell Change Success Measuremen ccOut]/
Ratio with SHO t per cell [VS.HSDPA.SHO.CellChg.At
(HSDPA to HSDPA) tOut]*{100}

Inter-frequency Hard % HSDPA [VS.HSDPA.HHO.SuccOu-


Handover Success Measuremen tInterFreq]/
Ratio (HSDPA to t per cell [VS.HSDPA.HHO.AttOutIn-
HSDPA) terFreq]*{100}

CS Inter-RAT % InterRAT [IRATHO.SuccOutCS]/


Handover Success Handover [IRATHO.AttOutCS]*{100}
Ratio (WCDMA to Measuremen
GSM)(Cell) t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 648


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

PS Inter-RAT % InterRAT [IRATHO.SuccOutPSU-


Handover Success Handover TRAN]/[IRATHO.AttOut-
Ratio (WCDMA to Measuremen PSUTRAN]*{100}
GPRS)(Cell) t per cell

HSDPA Inter-RAT % InterRAT [VS.IRATHO.HSDPA.Suc-


Handover Success Handover cOutPSUTRAN]/
Ratio (WCDMA to Measuremen [VS.IRATHO.HSDPA.At-
GPRS) t per cell tOutPSUTRAN]*{100}

E-DCH Soft % HSUPA [VS.HSUPA.EDCH.SHO.Suc


Handover Success Measuremen c]/
Ratio t per cell [VS.HSUPA.EDCH.SHO.Att]
*{100}

E-DCH Service Cell % HSUPA [VS.HSUPA.SHO.ServCellCh


Change Success Measuremen g.Succ]/
Ratio with SHO t per cell [VS.HSUPA.SHO.ServCellCh
(HSUPA to HSUPA) g.Att]*{100}

E-DCH Service Cell % HSUPA [VS.HSUPA.HHO.InterFreq.


Change Success Measuremen NoChR.Succ]/
Ratio with Inter- t per cell [VS.HSUPA.HHO.InterFreq.
HHO (HSUPA to NoChR.Att]*{100}
HSUPA)

E-DCH to DCH % HSUPA [VS.HSUPA.ChR.InterFreq.E


Handover Success Measuremen DCHtoDCH.Succ]/
Ratio (with Inter t per cell [VS.HSUPA.ChR.InterFreq.E
HHO) DCHtoDCH.Att]*{100}

HSUPA Inter-RAT % InterRAT [VS.HSUPA.IRATHO.Suc-


Handover Success Handover cOutPSUTRAN]/
Ratio (UTRAN to Measuremen [VS.HSUPA.IRATHO.At-
GPRS) t per cell tOutPSUTRAN]*{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 649


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

20.1.3 Retainability Report

Report Type
Simple Report

NE Type
RNC

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Retainabi AMR Call Drop % Measuremen [VS.RAB.Loss.CS.AMR]/


lity Ratio t of RAB ([VS.RAB.Loss.CS.AMR]+
release [VS.RAB.Loss.CS.Norm.AM
triggered by R])*{100}
UTRAN per
cell

VP Call Drop Ratio % Measuremen [VS.RAB.Loss.CS.Conv64K]/


t of RAB ([VS.Norm.Rel.CS.Conv.RB.
release 64]+
triggered by [VS.RAB.Loss.CS.Conv64K])
UTRAN per *{100}
cell

PS Service Drop % Measuremen ([VS.RAB.Loss.PS.RF]+


Ratio t of RAB [VS.RAB.Loss.PS.Abnorm])/
release ([VS.RAB.Loss.PS.RF]+
triggered by [VS.RAB.Loss.PS.Abnorm]+
UTRAN per [VS.RAB.Loss.PS.Norm])*
cell {100}

HSDPA Service % HSDPA ([VS.HSDPA.RAB.Loss.Abn


Drop Ratio Measuremen orm.NonRF]+
t per cell [VS.HSDPA.RAB.Loss.RF])/
([VS.HSDPA.RAB.Loss.Abn
orm.NonRF]+
[VS.HSDPA.RAB.Loss.RF]+
[VS.HSDPA.RAB.Loss.Norm
]+[VS.HSDPA.RAB.Loss.In-
Activity])*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 650


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

HSUPA Service % HSUPA [VS.HSUPA.RAB.Loss.Ab-


Drop Ratio Measuremen norm]/
t per cell ([VS.HSUPA.RAB.Loss.Ab-
norm]+
[VS.HSUPA.RAB.Loss.Norm
])*{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

20.1.4 Traffic Report

Report Type
Simple Report

NE Type
RNC

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Traffic HSDPA Mean UE numb HSDPA [VS.HSDPA.UE.Mean.Cell]


number er Measuremen
t per cell

HSDPA RLC Traffic byte HSDPA [VS.HSDPA.MeanChThrough


Volume Measuremen put.TotalBytes]
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 651


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

HSUPA Mean UE numb HSUPA [VS.HSUPA.UE.Mean.Cell]


number er Measuremen
t per cell

HSUPA RLC Traffic byte HSUPA [VS.HSUPA.MeanChThrough


Volume Measuremen put.TotalBytes]
t per cell

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

20.2 Coverage Evaluation Reports

20.2.1 Cell Load Analysis Report

Report Type
Simple Report

NE Type
3GRNC

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Cell VS.MeanTCP dBm TX and RX -


Load Power
Analysis Measuremen
t <per Cell>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 652


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.MaxTCP dBm TX and RX -


Power
Measuremen
t <per Cell>

VS.MinTCP dBm TX and RX -


Power
Measuremen
t <per Cell>

VS.MeanRTWP dBm TX and RX -


Power
Measuremen
t <per Cell>

VS.MaxRTWP dBm TX and RX -


Power
Measuremen
t <per Cell>

VS.MinRTWP dBm TX and RX -


Power
Measuremen
t <per Cell>

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

20.2.2 Coverage Evaluation Summary Report

Report Type
Combined Report

Simple Report(s) List


l RSCP Analysis Report
l EcNo Analysis Report
l TP Analysis Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 653


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

l UE TxPower Analysis Report


l Cell Load Analysis Report

RSCP Analysis Report

NE Type
3GRNC

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Access VS.RRC.Access.Wo % RRC MR


RSCP rse.RSCP.Ratio Measuremen
Segment t <per Cell>
Ratio
VS.RRC.Access.RS None RRC MR -
CP.0 Measuremen
t <per Cell>

VS.RRC.Access.RS None RRC MR -


CP.1 Measuremen
t <per Cell>

VS.RRC.Access.RS None RRC MR -


CP.2 Measuremen
t <per Cell>

VS.RRC.Access.RS None RRC MR -


CP.3 Measuremen
t <per Cell>

VS.RRC.Access.RS None RRC MR -


CP.4 Measuremen
t <per Cell>

VS.RRC.Access.RS None RRC MR -


CP.5 Measuremen
t <per Cell>

VS.RRC.Access.RS None RRC MR -


CP.6 Measuremen
t <per Cell>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 654


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RRC.Access.RS None RRC MR -


CP.7 Measuremen
t <per Cell>

VS.RRC.Access.RS None RRC MR -


CP.8 Measuremen
t <per Cell>

VS.RRC.Access.RS None RRC MR -


CP.9 Measuremen
t <per Cell>

SHO VS.SHO.Worse.RS % RRC MR


RSCP CP.Ratio Measuremen
Segment t <per Cell>
Ratio
VS.SHO.RSCP.0 None RRC MR -
Measuremen
t <per Cell>

VS.SHO.RSCP.1 None RRC MR -


Measuremen
t <per Cell>

VS.SHO.RSCP.2 None RRC MR -


Measuremen
t <per Cell>

VS.SHO.RSCP.3 None RRC MR -


Measuremen
t <per Cell>

VS.SHO.RSCP.4 None RRC MR -


Measuremen
t <per Cell>

VS.SHO.RSCP.5 None RRC MR -


Measuremen
t <per Cell>

VS.SHO.RSCP.6 None RRC MR -


Measuremen
t <per Cell>

VS.SHO.RSCP.7 None RRC MR -


Measuremen
t <per Cell>

VS.SHO.RSCP.8 None RRC MR -


Measuremen
t <per Cell>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 655


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.SHO.RSCP.9 None RRC MR -


Measuremen
t <per Cell>

MR VS.Periodic.MrRpt. % RRC MR
Report Worse.RSCP.Ratio Measuremen
RSCP t <per Cell>
Segment
Ratio VS.Periodic.MrRpt. None RRC MR -
RSCP.0 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


RSCP.1 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


RSCP.2 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


RSCP.3 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


RSCP.4 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


RSCP.5 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


RSCP.6 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


RSCP.7 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


RSCP.8 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


RSCP.9 Measuremen
t <per Cell>

Mean VS.RRC.MrRpt.SH None RRC MR -


SHO O.RSCP Measuremen
RSCP t <per Cell>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 656


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.MrRpt.Cum.SH None RRC MR -


O Measuremen
t <per Cell>

VS.RSCP.Cum.SHO dBm RRC MR -


Measuremen
t <per Cell>

EcNo Analysis Report

NE Type
3GRNC

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Access VS.RRC.Access.Wo % RRC MR


EcNo rse.EcNo.Ratio Measuremen
Segment t <per Cell>
Ratio
VS.RRC.Access.Ec- None RRC MR -
No.0 Measuremen
t <per Cell>

VS.RRC.Access.Ec- None RRC MR -


No.1 Measuremen
t <per Cell>

VS.RRC.Access.Ec- None RRC MR -


No.2 Measuremen
t <per Cell>

VS.RRC.Access.Ec- None RRC MR -


No.3 Measuremen
t <per Cell>

VS.RRC.Access.Ec- None RRC MR -


No.4 Measuremen
t <per Cell>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 657


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RRC.Access.Ec- None RRC MR -


No.5 Measuremen
t <per Cell>

VS.RRC.Access.Ec- None RRC MR -


No.6 Measuremen
t <per Cell>

VS.RRC.Access.Ec- None RRC MR -


No.7 Measuremen
t <per Cell>

VS.RRC.Access.Ec- None RRC MR -


No.8 Measuremen
t <per Cell>

Cell VS.Cell.Updt.Worse % RRC MR


Update .EcNo.Ratio Measuremen
EcNo t <per Cell>
Segment
Ratio VS.Cell.Updt.EcNo. None RRC MR -
0 Measuremen
t <per Cell>

VS.Cell.Updt.EcNo. None RRC MR -


1 Measuremen
t <per Cell>

VS.Cell.Updt.EcNo. None RRC MR -


2 Measuremen
t <per Cell>

VS.Cell.Updt.EcNo. None RRC MR -


3 Measuremen
t <per Cell>

VS.Cell.Updt.EcNo. None RRC MR -


4 Measuremen
t <per Cell>

VS.Cell.Updt.EcNo. None RRC MR -


5 Measuremen
t <per Cell>

VS.Cell.Updt.EcNo. None RRC MR -


6 Measuremen
t <per Cell>

VS.Cell.Updt.EcNo. None RRC MR -


7 Measuremen
t <per Cell>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 658


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.Cell.Updt.EcNo. None RRC MR -


8 Measuremen
t <per Cell>

SHO VS.SHO.Worse.EcN % RRC MR


EcNo o.Ratio Measuremen
Segment t <per Cell>
Ratio
VS.SHO.EcNo.0 None RRC MR -
Measuremen
t <per Cell>

VS.SHO.EcNo.1 None RRC MR -


Measuremen
t <per Cell>

VS.SHO.EcNo.2 None RRC MR -


Measuremen
t <per Cell>

VS.SHO.EcNo.3 None RRC MR -


Measuremen
t <per Cell>

VS.SHO.EcNo.4 None RRC MR -


Measuremen
t <per Cell>

VS.SHO.EcNo.5 None RRC MR -


Measuremen
t <per Cell>

VS.SHO.EcNo.6 None RRC MR -


Measuremen
t <per Cell>

VS.SHO.EcNo.7 None RRC MR -


Measuremen
t <per Cell>

VS.SHO.EcNo.8 None RRC MR -


Measuremen
t <per Cell>

MR VS.Periodic.MrRpt. % RRC MR
Report Worse.EcNo.Ratio Measuremen
EcNo t <per Cell>
Segment
Ratio VS.Periodic.MrRpt. None RRC MR -
EcNo.0 Measuremen
t <per Cell>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 659


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.Periodic.MrRpt. None RRC MR -


EcNo.1 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


EcNo.2 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


EcNo.3 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


EcNo.4 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


EcNo.5 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


EcNo.6 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


EcNo.7 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


EcNo.8 Measuremen
t <per Cell>

Mean VS.RRC.MrRpt.SH dB RRC MR -


SHO O.EcNo Measuremen
EcNo t <per Cell>

VS.EcNo.Cum.SHO dB RRC MR -
Measuremen
t <per Cell>

VS.EcNo.MrRpt.Cu None RRC MR -


m.SHO Measuremen
t <per Cell>

TP Analysis Report

NE Type
3GRNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 660


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

TP VS.TP.UE.Worse.R % RRC
Segment atio Connection
Ratio Setup
Measuremen
t <per Cell>

VS.TP.UE.0 None RRC -


Connection
Setup
Measuremen
t <per Cell>

VS.TP.UE.1 None RRC -


Connection
Setup
Measuremen
t <per Cell>

VS.TP.UE.2 None RRC -


Connection
Setup
Measuremen
t <per Cell>

VS.TP.UE.3 None RRC -


Connection
Setup
Measuremen
t <per Cell>

VS.TP.UE.4 None RRC -


Connection
Setup
Measuremen
t <per Cell>

VS.TP.UE.5 None RRC -


Connection
Setup
Measuremen
t <per Cell>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 661


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.TP.UE.6.9 None RRC -


Connection
Setup
Measuremen
t <per Cell>

VS.TP.UE.16.25 None RRC -


Connection
Setup
Measuremen
t <per Cell>

VS.TP.UE.26.35 None RRC -


Connection
Setup
Measuremen
t <per Cell>

VS.TP.UE.36.55 None RRC -


Connection
Setup
Measuremen
t <per Cell>

VS.TP.UE.More55 None RRC -


Connection
Setup
Measuremen
t <per Cell>

VS.TP.UE.10.15 None RRC -


Connection
Setup
Measuremen
t <per Cell>

Mean VS.RSCP.Mean.TP0 dBm RRC MR -


RSCP vs. Measuremen
TP t <per Cell>

VS.RSCP.Mean.TP1 dBm RRC MR -


Measuremen
t <per Cell>

VS.RSCP.Mean.TP2 dBm RRC MR -


Measuremen
t <per Cell>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 662


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RSCP.Mean.TP3 dBm RRC MR -


Measuremen
t <per Cell>

VS.RSCP.Mean.TP4 dBm RRC MR -


Measuremen
t <per Cell>

VS.RSCP.Mean.TP5 dBm RRC MR -


Measuremen
t <per Cell>

VS.RSCP.Mean.TP6 dBm RRC MR -


.9 Measuremen
t <per Cell>

VS.RSCP.Mean.TP1 dBm RRC MR -


0.15 Measuremen
t <per Cell>

VS.RSCP.Mean.TP1 dBm RRC MR -


6.25 Measuremen
t <per Cell>

VS.RSCP.Mean.TP2 dBm RRC MR -


6.35 Measuremen
t <per Cell>

VS.RSCP.Mean.TP3 dBm RRC MR -


6.55 Measuremen
t <per Cell>

VS.RSCP.Mean.TP. dBm RRC MR -


More55 Measuremen
t <per Cell>

VS.RSCP.cum.TP0 dBm RRC MR -


Measuremen
t <per Cell>

VS.RSCP.cum.TP1 dBm RRC MR -


Measuremen
t <per Cell>

VS.RSCP.cum.TP2 dBm RRC MR -


Measuremen
t <per Cell>

VS.RSCP.cum.TP3 dBm RRC MR -


Measuremen
t <per Cell>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 663


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RSCP.cum.TP4 dBm RRC MR -


Measuremen
t <per Cell>

VS.RSCP.cum.TP5 dBm RRC MR -


Measuremen
t <per Cell>

VS.RSCP.cum.TP6. dBm RRC MR -


9 Measuremen
t <per Cell>

VS.RSCP.cum.TP10 dBm RRC MR -


.15 Measuremen
t <per Cell>

VS.RSCP.cum.TP16 dBm RRC MR -


.25 Measuremen
t <per Cell>

VS.RSCP.cum.TP26 dBm RRC MR -


.35 Measuremen
t <per Cell>

VS.RSCP.cum.TP36 dBm RRC MR -


.55 Measuremen
t <per Cell>

VS.RSCP.cum.TP. dBm RRC MR -


More55 Measuremen
t <per Cell>

VS.RSCP.sample.TP None RRC MR -


0 Measuremen
t <per Cell>

VS.RSCP.sample.TP None RRC MR -


1 Measuremen
t <per Cell>

VS.RSCP.sample.TP None RRC MR -


2 Measuremen
t <per Cell>

VS.RSCP.sample.TP None RRC MR -


3 Measuremen
t <per Cell>

VS.RSCP.sample.TP None RRC MR -


4 Measuremen
t <per Cell>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 664


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RSCP.sample.TP None RRC MR -


5 Measuremen
t <per Cell>

VS.RSCP.sample.TP None RRC MR -


6.9 Measuremen
t <per Cell>

VS.RSCP.sample.TP None RRC MR -


10.15 Measuremen
t <per Cell>

VS.RSCP.sample.TP None RRC MR -


16.25 Measuremen
t <per Cell>

VS.RSCP.sample.TP None RRC MR -


26.35 Measuremen
t <per Cell>

VS.RSCP.sample.TP None RRC MR -


36.55 Measuremen
t <per Cell>

VS.RSCP.sample.TP None RRC MR -


.More55 Measuremen
t <per Cell>

Mean VS.EcNo.Mean.TP0 dB RRC -


EcNo vs. Connection
TP Setup
Measuremen
t <per Cell>

VS.EcNo.Mean.TP1 dB RRC -
Connection
Setup
Measuremen
t <per Cell>

VS.EcNo.Mean.TP2 dB RRC -
Connection
Setup
Measuremen
t <per Cell>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 665


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.EcNo.Mean.TP3 dB RRC -
Connection
Setup
Measuremen
t <per Cell>

VS.EcNo.Mean.TP4 dB RRC -
Connection
Setup
Measuremen
t <per Cell>

VS.EcNo.Mean.TP5 dB RRC -
Connection
Setup
Measuremen
t <per Cell>

VS.EcNo.Mean.TP6 dB RRC -
.9 Connection
Setup
Measuremen
t <per Cell>

VS.EcNo.Mean.TP1 dB RRC -
0.15 Connection
Setup
Measuremen
t <per Cell>

VS.EcNo.Mean.TP1 dB RRC -
6.25 Connection
Setup
Measuremen
t <per Cell>

VS.EcNo.Mean.TP2 dB RRC -
6.35 Connection
Setup
Measuremen
t <per Cell>

VS.EcNo.Mean.TP3 dB RRC -
6.55 Connection
Setup
Measuremen
t <per Cell>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 666


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.EcNo.Mean.TP. dB RRC -
More55 Connection
Setup
Measuremen
t <per Cell>

VS.EcNo.Cum.TP0 dB RRC -
Connection
Setup
Measuremen
t <per Cell>

VS.EcNo.Cum.TP1 dB RRC -
Connection
Setup
Measuremen
t <per Cell>

VS.EcNo.Cum.TP10 dB RRC -
.15 Connection
Setup
Measuremen
t <per Cell>

VS.EcNo.Cum.TP16 dB RRC -
.25 Connection
Setup
Measuremen
t <per Cell>

VS.EcNo.Cum.TP2 dB RRC -
Connection
Setup
Measuremen
t <per Cell>

VS.EcNo.Cum.TP26 dB RRC -
.35 Connection
Setup
Measuremen
t <per Cell>

VS.EcNo.Cum.TP3 dB RRC -
Connection
Setup
Measuremen
t <per Cell>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 667


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.EcNo.Cum.TP36 dB RRC -
.55 Connection
Setup
Measuremen
t <per Cell>

VS.EcNo.Cum.TP4 dB RRC -
Connection
Setup
Measuremen
t <per Cell>

VS.EcNo.Cum.TP5 dB RRC -
Connection
Setup
Measuremen
t <per Cell>

VS.EcNo.Cum.TP6. dB RRC -
9 Connection
Setup
Measuremen
t <per Cell>

VS.EcNo.Cum.TP. dB RRC -
More55 Connection
Setup
Measuremen
t <per Cell>

UE TxPower Analysis Report

NE Type
3GRNC

Object Type
UCell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 668


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

UE VS.Periodic.MrRpt. % RRC MR
TxPower UETxPower.Worse. Measuremen
Segment Ratio t <per Cell>
Ratio
VS.Periodic.MrRpt. None RRC MR -
UETxPower.0 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


UETxPower.1 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


UETxPower.2 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


UETxPower.3 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


UETxPower.4 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


UETxPower.5 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


UETxPower.6 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


UETxPower.7 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


UETxPower.8 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


UETxPower.9 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


UETxPower.10 Measuremen
t <per Cell>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 669


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.Periodic.MrRpt. None RRC MR -


UETxPower.11 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


UETxPower.12 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


UETxPower.13 Measuremen
t <per Cell>

Cell Load Analysis Report

NE Type
3GRNC

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Cell VS.MeanTCP dBm TX and RX -


Load Power
Analysis Measuremen
t <per Cell>

VS.MaxTCP dBm TX and RX -


Power
Measuremen
t <per Cell>

VS.MinTCP dBm TX and RX -


Power
Measuremen
t <per Cell>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 670


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.MeanRTWP dBm TX and RX -


Power
Measuremen
t <per Cell>

VS.MaxRTWP dBm TX and RX -


Power
Measuremen
t <per Cell>

VS.MinRTWP dBm TX and RX -


Power
Measuremen
t <per Cell>

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

20.2.3 EcNo Analysis Report

Report Type
Simple Report

NE Type
3GRNC

Object Type
UCell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 671


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Access VS.RRC.Access.Wo % RRC MR -


EcNo rse.EcNo.Ratio Measuremen
Segment t <per Cell>
Ratio
VS.RRC.Access.Ec- None RRC MR -
No.0 Measuremen
t <per Cell>

VS.RRC.Access.Ec- None RRC MR -


No.1 Measuremen
t <per Cell>

VS.RRC.Access.Ec- None RRC MR -


No.2 Measuremen
t <per Cell>

VS.RRC.Access.Ec- None RRC MR -


No.3 Measuremen
t <per Cell>

VS.RRC.Access.Ec- None RRC MR -


No.4 Measuremen
t <per Cell>

VS.RRC.Access.Ec- None RRC MR -


No.5 Measuremen
t <per Cell>

VS.RRC.Access.Ec- None RRC MR -


No.6 Measuremen
t <per Cell>

VS.RRC.Access.Ec- None RRC MR -


No.7 Measuremen
t <per Cell>

VS.RRC.Access.Ec- None RRC MR -


No.8 Measuremen
t <per Cell>

Cell VS.Cell.Updt.Worse % RRC MR -


Update .EcNo.Ratio Measuremen
EcNo t <per Cell>
Segment
Ratio VS.Cell.Updt.EcNo. None RRC MR -
0 Measuremen
t <per Cell>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 672


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.Cell.Updt.EcNo. None RRC MR -


1 Measuremen
t <per Cell>

VS.Cell.Updt.EcNo. None RRC MR -


2 Measuremen
t <per Cell>

VS.Cell.Updt.EcNo. None RRC MR -


3 Measuremen
t <per Cell>

VS.Cell.Updt.EcNo. None RRC MR -


4 Measuremen
t <per Cell>

VS.Cell.Updt.EcNo. None RRC MR -


5 Measuremen
t <per Cell>

VS.Cell.Updt.EcNo. None RRC MR -


6 Measuremen
t <per Cell>

VS.Cell.Updt.EcNo. None RRC MR -


7 Measuremen
t <per Cell>

VS.Cell.Updt.EcNo. None RRC MR -


8 Measuremen
t <per Cell>

SHO VS.SHO.Worse.EcN % RRC MR -


EcNo o.Ratio Measuremen
Segment t <per Cell>
Ratio
VS.SHO.EcNo.0 None RRC MR -
Measuremen
t <per Cell>

VS.SHO.EcNo.1 None RRC MR -


Measuremen
t <per Cell>

VS.SHO.EcNo.2 None RRC MR -


Measuremen
t <per Cell>

VS.SHO.EcNo.3 None RRC MR -


Measuremen
t <per Cell>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 673


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.SHO.EcNo.4 None RRC MR -


Measuremen
t <per Cell>

VS.SHO.EcNo.5 None RRC MR -


Measuremen
t <per Cell>

VS.SHO.EcNo.6 None RRC MR -


Measuremen
t <per Cell>

VS.SHO.EcNo.7 None RRC MR -


Measuremen
t <per Cell>

VS.SHO.EcNo.8 None RRC MR -


Measuremen
t <per Cell>

MR VS.Periodic.MrRpt. % RRC MR -
Report Worse.EcNo.Ratio Measuremen
EcNo t <per Cell>
Segment
Ratio VS.Periodic.MrRpt. None RRC MR -
EcNo.0 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


EcNo.1 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


EcNo.2 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


EcNo.3 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


EcNo.4 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


EcNo.5 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


EcNo.6 Measuremen
t <per Cell>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 674


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.Periodic.MrRpt. None RRC MR -


EcNo.7 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


EcNo.8 Measuremen
t <per Cell>

Mean VS.RRC.MrRpt.SH dB RRC MR -


SHO O.EcNo Measuremen
EcNo t <per Cell>

VS.EcNo.Cum.SHO dB RRC MR -
Measuremen
t <per Cell>

VS.EcNo.MrRpt.Cu None RRC MR -


m.SHO Measuremen
t <per Cell>

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

20.2.4 RSCP Analysis Report

Report Type
Simple Report

NE Type
3GRNC

Object Type
UCell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 675


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Access VS.RRC.Access.Wo % RRC MR -


RSCP rse.RSCP.Ratio Measuremen
Segment t <per Cell>
Ratio
VS.RRC.Access.RS None RRC MR -
CP.0 Measuremen
t <per Cell>

VS.RRC.Access.RS None RRC MR -


CP.1 Measuremen
t <per Cell>

VS.RRC.Access.RS None RRC MR -


CP.2 Measuremen
t <per Cell>

VS.RRC.Access.RS None RRC MR -


CP.3 Measuremen
t <per Cell>

VS.RRC.Access.RS None RRC MR -


CP.4 Measuremen
t <per Cell>

VS.RRC.Access.RS None RRC MR -


CP.5 Measuremen
t <per Cell>

VS.RRC.Access.RS None RRC MR -


CP.6 Measuremen
t <per Cell>

VS.RRC.Access.RS None RRC MR -


CP.7 Measuremen
t <per Cell>

VS.RRC.Access.RS None RRC MR -


CP.8 Measuremen
t <per Cell>

VS.RRC.Access.RS None RRC MR -


CP.9 Measuremen
t <per Cell>

SHO VS.SHO.Worse.RS % RRC MR -


RSCP CP.Ratio Measuremen
Segment t <per Cell>
Ratio

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 676


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.SHO.RSCP.0 None RRC MR -


Measuremen
t <per Cell>

VS.SHO.RSCP.1 None RRC MR -


Measuremen
t <per Cell>

VS.SHO.RSCP.2 None RRC MR -


Measuremen
t <per Cell>

VS.SHO.RSCP.3 None RRC MR -


Measuremen
t <per Cell>

VS.SHO.RSCP.4 None RRC MR -


Measuremen
t <per Cell>

VS.SHO.RSCP.5 None RRC MR -


Measuremen
t <per Cell>

VS.SHO.RSCP.6 None RRC MR -


Measuremen
t <per Cell>

VS.SHO.RSCP.7 None RRC MR -


Measuremen
t <per Cell>

VS.SHO.RSCP.8 None RRC MR -


Measuremen
t <per Cell>

VS.SHO.RSCP.9 None RRC MR -


Measuremen
t <per Cell>

MR VS.Periodic.MrRpt. % RRC MR -
Report Worse.RSCP.Ratio Measuremen
RSCP t <per Cell>
Segment
Ratio VS.Periodic.MrRpt. None RRC MR -
RSCP.0 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


RSCP.1 Measuremen
t <per Cell>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 677


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.Periodic.MrRpt. None RRC MR -


RSCP.2 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


RSCP.3 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


RSCP.4 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


RSCP.5 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


RSCP.6 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


RSCP.7 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


RSCP.8 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


RSCP.9 Measuremen
t <per Cell>

Mean VS.RRC.MrRpt.SH None RRC MR -


SHO O.RSCP Measuremen
RSCP t <per Cell>

VS.MrRpt.Cum.SH None RRC MR -


O Measuremen
t <per Cell>

VS.RSCP.Cum.SHO dBm RRC MR -


Measuremen
t <per Cell>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 678


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

20.2.5 TP Analysis Report

Report Type
Simple Report

NE Type
3GRNC

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

TP VS.TP.UE.Worse.R % RRC -
Segment atio Connection
Ratio Setup
Measuremen
t <per Cell>

VS.TP.UE.0 None RRC -


Connection
Setup
Measuremen
t <per Cell>

VS.TP.UE.1 None RRC -


Connection
Setup
Measuremen
t <per Cell>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 679


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.TP.UE.2 None RRC -


Connection
Setup
Measuremen
t <per Cell>

VS.TP.UE.3 None RRC -


Connection
Setup
Measuremen
t <per Cell>

VS.TP.UE.4 None RRC -


Connection
Setup
Measuremen
t <per Cell>

VS.TP.UE.5 None RRC -


Connection
Setup
Measuremen
t <per Cell>

VS.TP.UE.6.9 None RRC -


Connection
Setup
Measuremen
t <per Cell>

VS.TP.UE.16.25 None RRC -


Connection
Setup
Measuremen
t <per Cell>

VS.TP.UE.26.35 None RRC -


Connection
Setup
Measuremen
t <per Cell>

VS.TP.UE.36.55 None RRC -


Connection
Setup
Measuremen
t <per Cell>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 680


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.TP.UE.More55 None RRC -


Connection
Setup
Measuremen
t <per Cell>

VS.TP.UE.10.15 None RRC -


Connection
Setup
Measuremen
t <per Cell>

Mean VS.RSCP.Mean.TP0 dBm RRC MR -


RSCP vs. Measuremen
TP t <per Cell>

VS.RSCP.Mean.TP1 dBm RRC MR -


Measuremen
t <per Cell>

VS.RSCP.Mean.TP2 dBm RRC MR -


Measuremen
t <per Cell>

VS.RSCP.Mean.TP3 dBm RRC MR -


Measuremen
t <per Cell>

VS.RSCP.Mean.TP4 dBm RRC MR -


Measuremen
t <per Cell>

VS.RSCP.Mean.TP5 dBm RRC MR -


Measuremen
t <per Cell>

VS.RSCP.Mean.TP6 dBm RRC MR -


.9 Measuremen
t <per Cell>

VS.RSCP.Mean.TP1 dBm RRC MR -


0.15 Measuremen
t <per Cell>

VS.RSCP.Mean.TP1 dBm RRC MR -


6.25 Measuremen
t <per Cell>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 681


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RSCP.Mean.TP2 dBm RRC MR -


6.35 Measuremen
t <per Cell>

VS.RSCP.Mean.TP3 dBm RRC MR -


6.55 Measuremen
t <per Cell>

VS.RSCP.Mean.TP. dBm RRC MR -


More55 Measuremen
t <per Cell>

VS.RSCP.cum.TP0 dBm RRC MR -


Measuremen
t <per Cell>

VS.RSCP.cum.TP1 dBm RRC MR -


Measuremen
t <per Cell>

VS.RSCP.cum.TP2 dBm RRC MR -


Measuremen
t <per Cell>

VS.RSCP.cum.TP3 dBm RRC MR -


Measuremen
t <per Cell>

VS.RSCP.cum.TP4 dBm RRC MR -


Measuremen
t <per Cell>

VS.RSCP.cum.TP5 dBm RRC MR -


Measuremen
t <per Cell>

VS.RSCP.cum.TP6. dBm RRC MR -


9 Measuremen
t <per Cell>

VS.RSCP.cum.TP10 dBm RRC MR -


.15 Measuremen
t <per Cell>

VS.RSCP.cum.TP16 dBm RRC MR -


.25 Measuremen
t <per Cell>

VS.RSCP.cum.TP26 dBm RRC MR -


.35 Measuremen
t <per Cell>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 682


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RSCP.cum.TP36 dBm RRC MR -


.55 Measuremen
t <per Cell>

VS.RSCP.cum.TP. dBm RRC MR -


More55 Measuremen
t <per Cell>

VS.RSCP.sample.TP None RRC MR -


0 Measuremen
t <per Cell>

VS.RSCP.sample.TP None RRC MR -


1 Measuremen
t <per Cell>

VS.RSCP.sample.TP None RRC MR -


2 Measuremen
t <per Cell>

VS.RSCP.sample.TP None RRC MR -


3 Measuremen
t <per Cell>

VS.RSCP.sample.TP None RRC MR -


4 Measuremen
t <per Cell>

VS.RSCP.sample.TP None RRC MR -


5 Measuremen
t <per Cell>

VS.RSCP.sample.TP None RRC MR -


6.9 Measuremen
t <per Cell>

VS.RSCP.sample.TP None RRC MR -


10.15 Measuremen
t <per Cell>

VS.RSCP.sample.TP None RRC MR -


16.25 Measuremen
t <per Cell>

VS.RSCP.sample.TP None RRC MR -


26.35 Measuremen
t <per Cell>

VS.RSCP.sample.TP None RRC MR -


36.55 Measuremen
t <per Cell>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 683


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RSCP.sample.TP None RRC MR -


.More55 Measuremen
t <per Cell>

Mean VS.EcNo.Mean.TP0 dB RRC -


EcNo vs. Connection
TP Setup
Measuremen
t <per Cell>

VS.EcNo.Mean.TP1 dB RRC -
Connection
Setup
Measuremen
t <per Cell>

VS.EcNo.Mean.TP2 dB RRC -
Connection
Setup
Measuremen
t <per Cell>

VS.EcNo.Mean.TP3 dB RRC -
Connection
Setup
Measuremen
t <per Cell>

VS.EcNo.Mean.TP4 dB RRC -
Connection
Setup
Measuremen
t <per Cell>

VS.EcNo.Mean.TP5 dB RRC -
Connection
Setup
Measuremen
t <per Cell>

VS.EcNo.Mean.TP6 dB RRC -
.9 Connection
Setup
Measuremen
t <per Cell>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 684


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.EcNo.Mean.TP1 dB RRC -
0.15 Connection
Setup
Measuremen
t <per Cell>

VS.EcNo.Mean.TP1 dB RRC -
6.25 Connection
Setup
Measuremen
t <per Cell>

VS.EcNo.Mean.TP2 dB RRC -
6.35 Connection
Setup
Measuremen
t <per Cell>

VS.EcNo.Mean.TP3 dB RRC -
6.55 Connection
Setup
Measuremen
t <per Cell>

VS.EcNo.Mean.TP. dB RRC -
More55 Connection
Setup
Measuremen
t <per Cell>

VS.EcNo.Cum.TP0 dB RRC -
Connection
Setup
Measuremen
t <per Cell>

VS.EcNo.Cum.TP1 dB RRC -
Connection
Setup
Measuremen
t <per Cell>

VS.EcNo.Cum.TP10 dB RRC -
.15 Connection
Setup
Measuremen
t <per Cell>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 685


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.EcNo.Cum.TP16 dB RRC -
.25 Connection
Setup
Measuremen
t <per Cell>

VS.EcNo.Cum.TP2 dB RRC -
Connection
Setup
Measuremen
t <per Cell>

VS.EcNo.Cum.TP26 dB RRC -
.35 Connection
Setup
Measuremen
t <per Cell>

VS.EcNo.Cum.TP3 dB RRC -
Connection
Setup
Measuremen
t <per Cell>

VS.EcNo.Cum.TP36 dB RRC -
.55 Connection
Setup
Measuremen
t <per Cell>

VS.EcNo.Cum.TP4 dB RRC -
Connection
Setup
Measuremen
t <per Cell>

VS.EcNo.Cum.TP5 dB RRC -
Connection
Setup
Measuremen
t <per Cell>

VS.EcNo.Cum.TP6. dB RRC -
9 Connection
Setup
Measuremen
t <per Cell>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 686


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.EcNo.Cum.TP. dB RRC -
More55 Connection
Setup
Measuremen
t <per Cell>

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

20.2.6 UE TxPower Analysis Report

Report Type
Simple Report

NE Type
3GRNC

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

UE VS.Periodic.MrRpt. % RRC MR -
TxPower UETxPower.Worse. Measuremen
Segment Ratio t <per Cell>
Ratio
VS.Periodic.MrRpt. None RRC MR -
UETxPower.0 Measuremen
t <per Cell>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 687


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.Periodic.MrRpt. None RRC MR -


UETxPower.1 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


UETxPower.2 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


UETxPower.3 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


UETxPower.4 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


UETxPower.5 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


UETxPower.6 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


UETxPower.7 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


UETxPower.8 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


UETxPower.9 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


UETxPower.10 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


UETxPower.11 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


UETxPower.12 Measuremen
t <per Cell>

VS.Periodic.MrRpt. None RRC MR -


UETxPower.13 Measuremen
t <per Cell>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 688


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

20.3 RNC Reports

20.3.1 Accessibility Report

Report Type
Simple Report

NE Type
RNC

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Accessib IU Paging Success % Measuremen [VS.RANAP.Paging.Succ.Idle


ility Ratio t related to UE]/
Paging per [VS.RANAP.Paging.Att.IdleU
RNC E]*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 689


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Radio Access % RRC (([RRC.SuccConnEstab.Og-


Success Ratio connection ConvCall]+
setup [RRC.SuccConnEstab.OrgStr-
measurement Call]+
per cell [RRC.SuccConnEstab.OrgItr-
Call]+
[RRC.SuccConnEstab.OrgBk
gCall]+
[RRC.SuccConnEstab.Org-
SubCall]+
[RRC.SuccConnEstab.TmCon
vCall]+
[RRC.SuccConnEstab.TmStr
Call]+
[RRC.SuccConnEstab.TmItr-
Call]+
[RRC.SuccConnEstab.TmBkg
Call]+
[RRC.SuccConnEstab.Emg-
Call]+
[RRC.SuccConnEstab.Un-
kown]+
[RRC.SuccConnEstab.OgHhP
rSig]+
[RRC.SuccConnEstab.OgLwP
rSig]+
[RRC.SuccConnEstab.CallRe-
Est]+
[RRC.SuccConnEstab.TmHhP
rSig]+
[RRC.SuccConnEstab.TmLw
PrSig])/
([RRC.AttConnEstab.Org-
ConvCall]+
[RRC.AttConnEstab.OrgStr-
Call]+
[RRC.AttConnEstab.OrgInter-
Call]+
[RRC.AttConnEstab.OrgBkg-
Call]+
[RRC.AttConnEstab.OgSub-
Call]+
[RRC.AttConnEstab.TmConv
Call]+
[RRC.AttConnEstab.TmStrCa
ll]+
[RRC.AttConnEstab.TmInter-

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 690


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Call]+
[RRC.AttConnEstab.TmBkgC
all]+
[RRC.AttConnEstab.Emg-
Call]+
[RRC.AttConnEstab.Un-
known]+
[RRC.AttConnEstab.OgHhPr-
Sig]+
[RRC.AttConnEstab.OgLwPr-
Sig]+
[RRC.AttConnEstab.CallRe-
Est]+
[RRC.AttConnEstab.TmHhPr
Sig]+
[RRC.AttConnEstab.TmLwPr
Sig])*{100})*
(([VS.RAB.SuccEstabCS.Con
v]+
[VS.RAB.SuccEstabCS.Str])+
([VS.RAB.SuccEstabPS.Conv
]+[VS.RAB.SuccEstabPS.Str]
+[VS.RAB.SuccEstabPS.In-
ter]+
[VS.RAB.SuccEstabPS.Bkg]))
/
(([VS.RAB.AttEstabCS.Conv]
+[VS.RAB.AttEstabCS.Str])+
([VS.RAB.AttEstabPS.Conv]
+[VS.RAB.AttEstabPS.Str]+
[VS.RAB.AttEstabPS.Inter]+
[VS.RAB.AttEstabPS.Bkg]))

RRC Setup Success % RRC ([RRC.SuccConnEstab.IRAT-


Ratio(other) connection CelRes]+
setup [RRC.SuccConnEstab.IRATC
measurement CO]+
per cell [RRC.SuccConnEstab.Reg]+
[RRC.SuccConnEstab.De-
tach])/
([RRC.AttConnEstab.IRAT-
CelRes]+
[RRC.AttConnEstab.IRATC-
CO]+
[RRC.AttConnEstab.Reg]+
[RRC.AttConnEstab.Detach])
*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 691


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

RRC Setup Success % RRC ([RRC.SuccConnEstab.Og-


Ratio(service) connection ConvCall]+
setup [RRC.SuccConnEstab.OrgStr-
measurement Call]+
per cell [RRC.SuccConnEstab.OrgItr-
Call]+
[RRC.SuccConnEstab.OrgBk
gCall]+
[RRC.SuccConnEstab.Org-
SubCall]+
[RRC.SuccConnEstab.TmCon
vCall]+
[RRC.SuccConnEstab.TmStr
Call]+
[RRC.SuccConnEstab.TmItr-
Call]+
[RRC.SuccConnEstab.TmBkg
Call]+
[RRC.SuccConnEstab.Emg-
Call]+
[RRC.SuccConnEstab.Un-
kown]+
[RRC.SuccConnEstab.OgHhP
rSig]+
[RRC.SuccConnEstab.OgLwP
rSig]+
[RRC.SuccConnEstab.CallRe-
Est]+
[RRC.SuccConnEstab.TmHhP
rSig]+
[RRC.SuccConnEstab.TmLw
PrSig])/
([RRC.AttConnEstab.Org-
ConvCall]+
[RRC.AttConnEstab.OrgStr-
Call]+
[RRC.AttConnEstab.OrgInter-
Call]+
[RRC.AttConnEstab.OrgBkg-
Call]+
[RRC.AttConnEstab.OgSub-
Call]+
[RRC.AttConnEstab.TmConv
Call]+
[RRC.AttConnEstab.TmStrCa
ll]+
[RRC.AttConnEstab.TmInter-

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 692


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Call]+
[RRC.AttConnEstab.TmBkgC
all]+
[RRC.AttConnEstab.Emg-
Call]+
[RRC.AttConnEstab.Un-
known]+
[RRC.AttConnEstab.OgHhPr-
Sig]+
[RRC.AttConnEstab.OgLwPr-
Sig]+
[RRC.AttConnEstab.CallRe-
Est]+
[RRC.AttConnEstab.TmHhPr
Sig]+
[RRC.AttConnEstab.TmLwPr
Sig])*{100}

AMR RAB Setup % Measuremen [VS.RAB.SuccEstab.AMR]/


Success Ratio t of CS RAB [VS.RAB.AttEstab.AMR]*
assignment {100}
setup per cell

VP RAB Setup % Measuremen [VS.RAB.SuccEstCS.Conv.


Success Ratio t of CS RAB 64]/[VS.RAB.AttEstCS.Conv.
assignment 64]*{100}
setup per cell

PS RAB Setup % Measuremen ([VS.RAB.SuccEstabPS.Conv


Success Ratio t of PS RAB ]+[VS.RAB.SuccEstabPS.Str]
assignment +[VS.RAB.SuccEstabPS.In-
setup per cell ter]+
[VS.RAB.SuccEstabPS.Bkg])/
([VS.RAB.AttEstabPS.Conv]
+[VS.RAB.AttEstabPS.Str]+
[VS.RAB.AttEstabPS.Inter]+
[VS.RAB.AttEstabPS.Bkg])*
{100}

HSDPA RAB Setup % HSDPA [VS.HSDPA.RAB.SuccEs-


Success Ratio Measuremen tab]/[VS.HSDPA.RAB.AttEs-
t per cell tab]*{100}

HSUPA RAB Setup % HSUPA [VS.HSUPA.RAB.SuccEs-


Success Ratio Measuremen tab]/[VS.HSUPA.RAB.AttEs-
t per cell tab]*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 693


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

20.3.2 Coverage Report

Report Type
Simple Report

NE Type
RNC

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Coverage Soft Handover Ratio % Soft (([VS.SHO.AS.1]+


Handover ([VS.SHO.AS.2Softer]+
Measuremen [VS.SHO.AS.2Soft])*{2}+
t per RNC ([VS.SHO.AS.3Softer]+
[VS.SHO.AS.3Soft]+
[VS.SHO.AS.3Soft2Softer])*
{3})/([VS.SHO.AS.1]+
[VS.SHO.AS.2Softer]+
[VS.SHO.AS.2Soft]+
[VS.SHO.AS.3Softer]+
[VS.SHO.AS.3Soft]+
[VS.SHO.AS.3Soft2Softer])-
{1})*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 694


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

20.3.3 Mobility Report

Report Type
Simple Report

NE Type
RNC

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Mobility Soft Handover % Soft [VS.SHO.Succ]/


Success Ratio(RNC) Handover [VS.SHO.Att.RNC]*{100}
Measuremen
t per RNC

HS-DSCH Service % HSDPA [VS.HSDPA.SHO.CellChg.Su


Cell Change Success Measuremen ccOut]/
Ratio with SHO t per cell [VS.HSDPA.SHO.CellChg.At
(HSDPA to HSDPA) tOut]*{100}

Inter-frequency Hard % Hard [VS.HHO.InterFreq.Succ.RN


Handover Success Handover C]/
Ratio Measuremen [VS.HHO.InterFreq.Att.RNC]
t per RNC *{100}

Inter-frequency Hard % HSDPA [VS.HSDPA.HHO.SuccOu-


Handover Success Measuremen tInterFreq]/
Ratio (HSDPA to t per cell [VS.HSDPA.HHO.AttOutIn-
HSDPA) terFreq]*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 695


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

CS Inter-RAT % Measuremen [VS.IRATHO.SuccCSOut.RN


Handover Success t related to C]/
Ratio (WCDMA to CS IRA [VS.IRATHO.AttCSOut.RNC
GSM)(RNC) handover per ]*{100}
RNC

PS Inter-RAT % Measuremen [VS.IRATHO.SuccPSOutUT


Handover Success t related to PS RAN.RNC]/
Ratio (WCDMA to IRA [VS.IRATHO.AttPSOutUTR
GPRS)(RNC) handover per AN.RNC]*{100}
RNC

HSDPA Inter-RAT % InterRAT [VS.IRATHO.HSDPA.Suc-


Handover Success Handover cOutPSUTRAN]/
Ratio (WCDMA to Measuremen [VS.IRATHO.HSDPA.At-
GPRS) t per cell tOutPSUTRAN]*{100}

TRNC Relocation % Measuremen ([VS.TRELOC.SuccExec.UEI


Success Ratio t of relocation nv]+
per DRNC [VS.TRELOC.SuccExec.UE-
NotInv])/
([VS.TRELOC.AttPrep.UEInv
]+[VS.TRELOC.AttPrep.UE-
NonInv])*{100}

E-DCH Soft % HSUPA [VS.HSUPA.EDCH.SHO.Suc


Handover Success Measuremen c]/
Ratio t per cell [VS.HSUPA.EDCH.SHO.Att]
*{100}

E-DCH Service Cell % HSUPA [VS.HSUPA.SHO.ServCellCh


Change Success Measuremen g.Succ]/
Ratio with SHO t per cell [VS.HSUPA.SHO.ServCellCh
(HSUPA to HSUPA) g.Att]*{100}

E-DCH Service Cell % HSUPA [VS.HSUPA.HHO.InterFreq.


Change Success Measuremen NoChR.Succ]/
Ratio with Inter- t per cell [VS.HSUPA.HHO.InterFreq.
HHO (HSUPA to NoChR.Att]*{100}
HSUPA)

E-DCH to DCH % HSUPA [VS.HSUPA.ChR.InterFreq.E


Handover Success Measuremen DCHtoDCH.Succ]/
Ratio (with Inter t per cell [VS.HSUPA.ChR.InterFreq.E
HHO) DCHtoDCH.Att]*{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 696


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

HSUPA Inter-RAT % InterRAT [VS.HSUPA.IRATHO.Suc-


Handover Success Handover cOutPSUTRAN]/
Ratio (UTRAN to Measuremen [VS.HSUPA.IRATHO.At-
GPRS) t per cell tOutPSUTRAN]*{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

20.3.4 Retainability Report

Report Type
Simple Report

NE Type
RNC

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Retainabi AMR Call Drop % Measuremen [VS.RAB.Loss.CS.AMR]/


lity Ratio t of RAB ([VS.RAB.Loss.CS.AMR]+
release [VS.RAB.Loss.CS.Norm.AM
triggered by R])*{100}
UTRAN per
cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 697


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VP Call Drop Ratio % Measuremen [VS.RAB.Loss.CS.Conv64K]/


t of RAB ([VS.Norm.Rel.CS.Conv.RB.
release 64]+
triggered by [VS.RAB.Loss.CS.Conv64K])
UTRAN per *{100}
cell

PS Service Drop % Measuremen ([VS.RAB.Loss.PS.RF]+


Ratio t of RAB [VS.RAB.Loss.PS.Abnorm])/
release ([VS.RAB.Loss.PS.RF]+
triggered by [VS.RAB.Loss.PS.Abnorm]+
UTRAN per [VS.RAB.Loss.PS.Norm])*
cell {100}

HSDPA Service % HSDPA ([VS.HSDPA.RAB.Loss.Abn


Drop Ratio Measuremen orm.NonRF]+
t per cell [VS.HSDPA.RAB.Loss.RF])/
([VS.HSDPA.RAB.Loss.Abn
orm.NonRF]+
[VS.HSDPA.RAB.Loss.RF]+
[VS.HSDPA.RAB.Loss.Norm
]+[VS.HSDPA.RAB.Loss.In-
Activity])*{100}

HSUPA Service % HSUPA [VS.HSUPA.RAB.Loss.Ab-


Drop Ratio Measuremen norm]/
t per cell ([VS.HSUPA.RAB.Loss.Ab-
norm]+
[VS.HSUPA.RAB.Loss.Norm
])*{100}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

20.3.5 Traffic Report

Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 698


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

NE Type
RNC

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Traffic CS Equivalent Erl Traffic [VS.CSLoad.Erlang.Equiv.RN


Traffic Measuremen C]
t per RNC

PS UL Throughput kbit/s Traffic [VS.PSLoad.ULThruput.RNC


Measuremen ]
t per RNC

PS DL Throughput kbit/s Traffic [VS.PSLoad.DLThruput.RNC


Measuremen ]
t per RNC

AMR12.2KDL_Erl Erl Measuremen [VS.AMR.Ctrl.DL12.2]


(Cell) t of RB
Procedure
per cell

CSConv64KDL_Erl Erl Measuremen [VS.RB.DLConvCS.64]


(Cell) t of RB
Procedure
per cell

HSDPA Mean UE numb HSDPA [VS.HSDPA.UE.Mean.Cell]


number er Measuremen
t per cell

HSDPA RLC Traffic byte HSDPA [VS.HSDPA.MeanChThrough


Volume Measuremen put.TotalBytes]
t per cell

HSUPA Mean UE numb HSUPA [VS.HSUPA.UE.Mean.Cell]


number er Measuremen
t per cell

HSUPA RLC Traffic byte HSUPA [VS.HSUPA.MeanChThrough


Volume Measuremen put.TotalBytes]
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 699


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

20.3.6 UMTS KPI Overview Report

Report Type
Simple Report

NE Type
RNC

Object Type
RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 700


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Accessab RRC Connection none RRC (([RRC.SuccConnEstab.Og-


ility Establishment connection ConvCall]+
Success Rate setup [RRC.SuccConnEstab.OrgStr-
(Service) measurement Call]+
per cell [RRC.SuccConnEstab.OrgItr-
Call]+
[RRC.SuccConnEstab.OrgBk
gCall]+
[RRC.SuccConnEstab.Org-
SubCall]+
[RRC.SuccConnEstab.TmCon
vCall]+
[RRC.SuccConnEstab.TmStr
Call]+
[RRC.SuccConnEstab.TmItr-
Call]+
[RRC.SuccConnEstab.TmBkg
Call]+
[RRC.SuccConnEstab.OgHhP
rSig]+
[RRC.SuccConnEstab.OgLwP
rSig]+
[RRC.SuccConnEstab.TmHhP
rSig]+
[RRC.SuccConnEstab.TmLw
PrSig]+
[RRC.SuccConnEstab.CallRe-
Est]+
[RRC.SuccConnEstab.Emg-
Call]+
[RRC.SuccConnEstab.Un-
kown]))/
(([RRC.AttConnEstab.Org-
ConvCall]+
[RRC.AttConnEstab.OrgStr-
Call]+
[RRC.AttConnEstab.OrgInter-
Call]+
[RRC.AttConnEstab.OrgBkg-
Call]+
[RRC.AttConnEstab.OgSub-
Call]+
[RRC.AttConnEstab.TmConv
Call]+
[RRC.AttConnEstab.TmStrCa

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 701


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

ll]+
[RRC.AttConnEstab.TmInter-
Call]+
[RRC.AttConnEstab.TmBkgC
all]+
[RRC.AttConnEstab.OgHhPr-
Sig]+
[RRC.AttConnEstab.OgLwPr-
Sig]+
[RRC.AttConnEstab.TmHhPr
Sig]+
[RRC.AttConnEstab.TmLwPr
Sig]+
[RRC.AttConnEstab.CallRe-
Est]+
[RRC.AttConnEstab.Emg-
Call]+
[RRC.AttConnEstab.Un-
known]))

RRC Connection none RRC ([RRC.SuccConnEstab.IRAT-


Establishment connection CelRes]+
Success Rate (Other) setup [RRC.SuccConnEstab.IRATC
measurement CO]+
per cell [RRC.SuccConnEstab.Reg]+
[RRC.SuccConnEstab.De-
tach])/
([RRC.AttConnEstab.IRAT-
CelRes]+
[RRC.AttConnEstab.IRATC-
CO]+
[RRC.AttConnEstab.Reg]+
[RRC.AttConnEstab.Detach])

RAB Establishment none Measuremen ([VS.RAB.SuccEstab.AMR.S


Success Rate - CS t of CS RAB PU]+
assignment [VS.RAB.SuccEstCS.Conv.
setup per 64.SPU])/
RNC ([VS.RAB.AttEstab.AMR.PL
MN.RNC]+
[VS.RAB.AttEstCS.Conv.64])

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 702


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

RAB Establishment none Measuremen ([VS.RAB.SuccEstabPS.Conv


Success Rate-PS t of PS RAB ]+[VS.RAB.SuccEstabPS.Str]
assignment +[VS.RAB.SuccEstabPS.In-
setup per cell ter]+
[VS.RAB.SuccEstabPS.Bkg])/
([VS.RAB.AttEstabPS.Conv]
+[VS.RAB.AttEstabPS.Str]+
[VS.RAB.AttEstabPS.Inter]+
[VS.RAB.AttEstabPS.Bkg])

RAB Establishment none HSDPA ([VS.HSDPA.RAB.SuccEs-


Success Rate- Measuremen tab])/([VS.HSDPA.RAB.At-
HSDPA t per cell tEstab])

RAB Establishment none HSUPA ([VS.HSUPA.RAB.SuccEs-


Success Rate- Measuremen tab])/([VS.HSUPA.RAB.At-
HSUPA t per cell tEstab])

Retainabi CS Call Drop Rate- none Measuremen ([VS.RAB.Loss.CS.AMR])/


lity Voice t of RAB ([VS.RAB.Loss.CS.AMR]+
release [VS.RAB.Loss.CS.Norm.AM
triggered by R])
UTRAN per
cell

CS Call Drop Rate- none Measuremen ([VS.RAB.Loss.CS.Conv64K]


VP t of RAB )/
release ([VS.Norm.Rel.CS.Conv.RB.
triggered by 64]+
UTRAN per [VS.RAB.Loss.CS.Conv64K])
cell

PS Call Drop Rate- none Measuremen ([VS.RAB.Loss.PS.RF]+


PS(Total) t of RAB [VS.RAB.Loss.PS.Abnorm])/
release ([VS.RAB.Loss.PS.RF]+
triggered by [VS.RAB.Loss.PS.Abnorm]+
UTRAN per [VS.RAB.Loss.PS.Norm])
cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 703


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

PS Call Drop Rate- none HSDPA ([VS.HSDPA.RAB.Loss.Abn


HSDPA Measuremen orm.NonRF]+
t per cell [VS.HSDPA.RAB.Loss.RF])/
([VS.HSDPA.RAB.Loss.Nor
m]+
[VS.HSDPA.RAB.Loss.InAc-
tivity]+
[VS.HSDPA.RAB.Loss.RF]+
[VS.HSDPA.RAB.Loss.Abno
rm.NonRF]+
[VS.HSDPA.ChR.HSDSCHto
DCH]+
[VS.HSDPA.ChR.HSDSCHto
FACH]+
[VS.HSDPA.HHO.H2D.Suc-
cOutIntraFreq]+
[VS.HSDPA.HHO.H2D.Suc-
cOutInterFreq])

PS Call Drop Rate- none HSDPA ([VS.HSUPA.RAB.Loss.Ab-


HSUPA Measuremen norm])/
t per cell ([VS.HSUPA.RAB.Loss.Ab-
norm]+
[VS.HSUPA.RAB.Loss.Norm
]+
[VS.HSUPA.ChR.IntraCell.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.IntraFreq.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.InterFreq.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.EDCHtoFA
CH.Succ])

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 704


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

RRC Drop Rate none RRC (([RRC.AttConnRelDCCH.Co


connection ngestion]+
release [RRC.AttConnRelCCCH.Con
measurement gestion]+
per cell [RRC.AttConnRelDCCH.Re-
EstRej]+
[RRC.AttConnRelCCCH.Re-
EstRej]+
[RRC.AttConnRelDCCH.Un-
spec]+
[RRC.AttConnRelCCCH.Un-
spec]-[VS.RAB.Loss.CS.Ab-
norm]-
[VS.RAB.Loss.CS.RF]-
[VS.RAB.Loss.PS.RF]-
[VS.RAB.Loss.PS.Abnorm]))/
(([RRC.AttConnRelDCCH.No
rmRel]+
[RRC.AttConnRelCCCH.Nor
mRel]+
[RRC.AttConnRelDCCH.Con
gestion]+
[RRC.AttConnRelCCCH.Con
gestion]+
[RRC.AttConnRelDCCH.Pre-
empt]+
[RRC.AttConnRelCCCH.Pre-
empt]+
[RRC.AttConnRelDCCH.Re-
EstRej]+
[RRC.AttConnRelCCCH.Re-
EstRej]+
[RRC.AttConnRelDCCH.Sig-
ConReEst]+
[RRC.AttConnRelCCCH.Sig-
ConReEst]+
[RRC.AttConnRelDCCH.Us-
rInact]+
[RRC.AttConnRelCCCH.Us-
rInact]+
[RRC.AttConnRelDCCH.Un-
spec]+
[RRC.AttConnRelCCCH.Un-
spec]))

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 705


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Mobility Soft Handover none Soft ([VS.SoHO.ASU.SuccR-


Success Rate Handover LAdd]+
Measuremen [VS.SoHO.ASU.SuccRlDel]+
t per cell [SHO.SuccRLAddUESide]+
[SHO.SuccRLDelUESide])/
([VS.SoHO.ASU.AttRLAdd]+
[VS.SoHO.ASU.AttRlDel]+
[SHO.AttRLAddUESide]+
[SHO.AttRLDelUESide])

Intra-Frequency none Hard ([VS.HHO.SuccOutIntraNo-


Hard Handover Handover deBIntraFreq]+
Success Rate Measuremen [VS.HHO.SuccOutInterNode-
t per cell BIntraRNCIntraFreq]+
[VS.HHO.SuccOutInterRN-
CIntraFreqIur])/
([VS.HHO.AttOutIntraNode-
BIntraFreq]+
[VS.HHO.AttOutInterNode-
BIntraRNCIntraFreq]+
[VS.HHO.AttOutInterRNCIn-
traFreqIur])

Inter-Frequency none Hard ([VS.HHO.InterFreq.Suc-


Hard Handover Handover cOut])/
Success Rate-CS&/ Measuremen ([VS.HHO.InterFreq.AttOut])
PS t per cell

Inter-Frequency none Hard ([VS.HHO.SuccOutIntraNo-


Hard Handover Handover deBInterFreq]+
Success Rate-intra- Measuremen [VS.HHO.SuccOutInterNode-
RNC t per cell BIntraRNCInterFreq])/
([VS.HHO.AttOutIntraNode-
BInterFreq]+
[VS.HHO.AttOutInterNode-
BIntraRNCInterFreq])

Inter-Frequency none Hard [VS.HHO.SuccOutInterRN-


Hard Handover Handover CInterFreqIur]/
Success Rate-inter- Measuremen [VS.HHO.AttOutInterRNCIn-
RNC t per cell terFreqIur]

HSDPA Serving Cell none HSDPA ([VS.HSDPA.SHO.CellChg.S


Change Success Rate Measuremen uccOut])/
(with Soft Handover) t per cell ([VS.HSDPA.SHO.CellChg.A
ttOut])

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 706


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

HSDPA Serving Cell none HSDPA [VS.HSDPA.HHO.SuccOu-


Change Success Rate Measuremen tIntraFreq]/
(with Intra- t per cell [VS.HSDPA.HHO.AttOutIn-
Frequency Hard traFreq]
Handover)

HSDPA Serving Cell none HSDPA ([VS.HSDPA.HHO.SuccOu-


Change Success Rate Measuremen tInterFreq])/
(with Inter- t per cell ([VS.HSDPA.HHO.AttOutIn-
Frequency Hard terFreq])
Handover)

HSUPA Serving Cell none HSUPA ([VS.HSUPA.SHO.ServCellC


Change Success Rate Measuremen hg.Succ])/
(with Soft Handover) t per cell ([VS.HSUPA.SHO.ServCellC
hg.Att])

HSUPA Serving Cell none HSUPA ([VS.HSUPA.HHO.IntraFreq.


Change Success Rate Measuremen NoChR.Succ])/
(with Intra- t per cell ([VS.HSUPA.HHO.IntraFreq.
Frequency Hard NoChR.Att])
Handover)

HSUPA Serving Cell none HSUPA ([VS.HSUPA.HHO.InterFreq.


Change Success Rate Measuremen NoChR.Succ])/
(with Inter- t per cell ([VS.HSUPA.HHO.InterFreq.
Frequency Hard NoChR.Att])
Handover)

Handover Success none InterRAT ([IRATHO.SuccOutCS])/


Rate (3G to 2G)- Handover ([IRATHO.AttOutCS])
Voice Measuremen
t per cell

Handover Success none InterRAT ([IRATHO.SuccOutPSU-


Rate (3G to 2G)-PS Handover TRAN])/([IRATHO.AttOut-
Measuremen PSUTRAN])
t per cell

Handover Success none InterRAT [VS.IRATHO.HSDPA.Suc-


Rate (3G to 2G)- Handover cOutPSUTRAN]/
HSDPA Measuremen [VS.IRATHO.HSDPA.At-
t per cell tOutPSUTRAN]

Handover Success none InterRAT [VS.HSUPA.IRATHO.Suc-


Rate (3G to 2G)- Handover cOutPSUTRAN]/
HSUPA Measuremen [VS.HSUPA.IRATHO.At-
t per cell tOutPSUTRAN]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 707


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Handover Success none InterRAT [IRATHO.SuccIncCS]/


Rate (2G to 3G)- Handover [VS.IRATHO.PrepSuccCSIn]
Voice Measuremen
t per cell

Handover Success none RRC [VS.RRC.SuccConnEstab.Cell


Rate (2G to 3G)-PS connection Res]/
setup [VS.RRC.AttConnEstab.CellR
measurement es]
per RNC

Traffic CS Traffic (Erl) none Traffic [VS.CSLoad.Erlang.Equiv.RN


Measuremen C]
t per RNC

R99 PS DL none Traffic [VS.PSLoad.kbits.DL.0.32]+


Throughput(kbit) Measuremen [VS.PSLoad.kbits.DL.32.64]+
t per RNC [VS.PSLoad.kbits.DL.64.144]
+[VS.PSLoad.kbits.DL.
144.384]

R99 PS UL none Traffic [VS.PSLoad.kbits.UL.0.32]+


Throughput(kbit) Measuremen [VS.PSLoad.kbits.UL.32.64]+
t per RNC [VS.PSLoad.kbits.UL.64.144]
+[VS.PSLoad.kbits.UL.
144.384]

HSDPA Throughput none HSDPA [VS.HSDPA.MeanChThrough


(kbit) Measuremen put.TotalBytes]*{8}/{1000}
t per cell

HSUPA Throughput none HSUPA [VS.HSUPA.MeanChThrough


(kbit) Measuremen put.TotalBytes]*{8}/{1000}
t per cell

MBMS Throughput none Traffic [VS.MBMSPSLoad.DLThrup


(kbit) Measuremen ut.RNC]*{GP}*{60}
t per RNC

Availabil Code Usage none Measuremen [VS.RAB.SFOccupy]/{256}


ity t of multi-
RAB service
per cell

TCP Usage none Cell TX and [VS.MeanTCP]


RX Power
Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 708


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

20.4 Troubleshooting Reports

20.4.1 CS Call Drop Cells Report

Report Type
Simple Report

NE Type
RNC

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

CS Call VS.CS.Call.Drop.Ce numb Measuremen [VS.RAB.Loss.CS.RF]+


Drop ll er t of RAB [VS.RAB.Loss.CS.Abnorm]
Cells release
triggered by
UTRAN per
cell

VS.RAB.Loss.CS numb Measuremen [VS.RAB.Loss.CS.RF]+


er t of RAB [VS.RAB.Loss.CS.Abnorm]+
release [VS.RAB.Loss.CS.Norm]
triggered by
UTRAN per
cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 709


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.RelReqCS. numb Measuremen -


OM er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.RelReqCS. numb Measuremen -


RABPreempt er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.RelReqCS. numb Measuremen -


UTRANgen er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.CS.R numb Measuremen -


F.RLCRst er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.CS.R numb Measuremen -


F.ULSync er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.CS.R numb Measuremen -


F.UuNoReply er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.CS.R numb Measuremen -


F.Oth er t of RAB
release
triggered by
UTRAN per
cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 710


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.Loss.CS.A numb Measuremen -


al2Loss er t of RAB
release
triggered by
UTRAN per
cell

VS.Call.Drop.CS.Ot numb Measuremen [VS.RAB.Loss.CS.Abnorm]-


her er t of RAB [VS.RAB.RelReqCS.OM]-
release [VS.RAB.RelReqCS.UTRAN
triggered by gen]-
UTRAN per [VS.RAB.RelReqCS.RAB-
cell Preempt]-
[VS.RAB.Loss.CS.Aal2Loss]

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

20.4.2 CS RAB Fail Report

Report Type
Simple Report

NE Type
RNC

Object Type
UCell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 711


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

CS RAB VS.RAB.FailEstabC numb Measuremen [VS.RAB.AttEstabCS.Conv]+


Fail S.Cell er t of CS RAB [VS.RAB.AttEstabCS.Str]-
assignment [VS.RAB.SuccEstabCS.Conv]
setup per cell -[VS.RAB.SuccEstabCS.Str]

VS.RAB.AttEstabC numb Measuremen [VS.RAB.AttEstabCS.Conv]+


S.Cell er t of CS RAB [VS.RAB.AttEstabCS.Str]
assignment
setup per cell

VS.RAB.FailEstabC numb Measuremen -


S.TNL er t of CS RAB
assignment
failure per
cell

VS.RAB.FailEstCS. numb Measuremen -


Relo er t of CS RAB
assignment
failure per
cell

VS.RAB.FailEstCS. numb Measuremen -


RIPFail er t of CS RAB
assignment
failure per
cell

VS.RAB.FailEstCs. numb Measuremen -


Power.Cong er t of CS RAB
assignment
failure per
cell

VS.RAB.FailEstCs. numb Measuremen -


ULCE.Cong er t of CS RAB
assignment
failure per
cell

VS.RAB.FailEstCs. numb Measuremen -


DLCE.Cong er t of CS RAB
assignment
failure per
cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 712


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.FailEstCs. numb Measuremen -


Code.Cong er t of CS RAB
assignment
failure per
cell

VS.RAB.FailEstCs.I numb Measuremen -


UB.Band er t of CS RAB
assignment
failure per
cell

VS.RAB.FailEstabC numb Measuremen [VS.RAB.FailEstCS.Unsp]-


S.Unsp.Other er t of CS RAB [VS.RAB.FailEstabCS.Cong]
assignment
failure per
cell

VS.RAB.FailEstabC numb Measuremen [VS.RAB.FailEstabCS.RNL]-


S.RNL.Other er t of CS RAB [VS.RAB.FailEstCS.Relo]-
assignment [VS.RAB.FailEstCS.RIPFail]-
failure per [VS.RAB.FailEstabCS.Cong]
cell

VS.RAB.FailEstabC numb Measuremen ([VS.RAB.AttEstabCS.Conv]


S.Other.Cell er t of CS RAB +[VS.RAB.AttEstabCS.Str]-
assignment [VS.RAB.SuccEstabCS.Conv]
setup per cell -[VS.RAB.SuccEstabCS.Str])-
[VS.RAB.FailEstabCS.RNL]-
[VS.RAB.FailEstabCS.TNL]

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

20.4.3 PS Call Drop Cells Report

Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 713


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

NE Type
RNC

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

PS Call VS.PS.Call.Drop.Ce numb Measuremen [VS.RAB.Loss.PS.RF]+


Drop ll er t of RAB [VS.RAB.Loss.PS.Abnorm]
Cells release
triggered by
UTRAN per
cell

VS.RAB.Loss.PS numb Measuremen [VS.RAB.Loss.PS.RF]+


er t of RAB [VS.RAB.Loss.PS.Abnorm]+
release [VS.RAB.Loss.PS.Norm]
triggered by
UTRAN per
cell

VS.RAB.RelReqPS. numb Measuremen -


OM er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.RelReqPS. numb Measuremen -


RABPreempt er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.RelReqPS. numb Measuremen -


UTRANgen er t of RAB
release
triggered by
UTRAN per
cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 714


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.Loss.PS.R numb Measuremen -


F.RLCRst er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.PS.R numb Measuremen -


F.ULSync er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.PS.R numb Measuremen -


F.UuNoReply er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.PS.R numb Measuremen -


F.Oth er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.PS.G numb Measuremen -


TPULoss er t of RAB
release
triggered by
UTRAN per
cell

VS.Call.Drop.PS.Ot numb Measuremen [VS.RAB.Loss.PS.Abnorm]-


her er t of RAB [VS.RAB.RelReqPS.OM]-
release [VS.RAB.RelReqPS.RAB-
triggered by Preempt]-
UTRAN per [VS.RAB.Loss.PS.GTPU-
cell Loss]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 715


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

20.4.4 PS RAB Fail Report

Report Type
Simple Report

NE Type
RNC

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

PS RAB VS.RAB.FailEstabP numb Measuremen ([VS.RAB.AttEstabPS.Conv]


Fail S.Cell er t of PS RAB +[VS.RAB.AttEstabPS.Str]+
assignment [VS.RAB.AttEstabPS.Inter]+
setup per cell [VS.RAB.AttEstabPS.Bkg])-
([VS.RAB.SuccEstabPS.Conv
]+[VS.RAB.SuccEstabPS.Str]
+[VS.RAB.SuccEstabPS.In-
ter]+
[VS.RAB.SuccEstabPS.Bkg])

VS.RAB.AttEstabPS numb Measuremen [VS.RAB.AttEstabPS.Conv]+


.Cell er t of PS RAB [VS.RAB.AttEstabPS.Str]+
assignment [VS.RAB.AttEstabPS.Inter]+
setup per cell [VS.RAB.AttEstabPS.Bkg]

VS.RAB.FailEstPS. numb Measuremen -


TNL er t of PS RAB
assignment
failure per
cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 716


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.FailEstPS. numb Measuremen -


RIPFail er t of PS RAB
assignment
failure per
cell

VS.RAB.FailEstPS. numb Measuremen -


Par er t of PS RAB
assignment
failure per
cell

VS.RAB.FailEstPS. numb Measuremen -


Relo er t of PS RAB
assignment
failure per
cell

VS.RAB.FailEstPs.P numb Measuremen -


ower.Cong er t of PS RAB
assignment
failure per
cell

VS.RAB.FailEstPs. numb Measuremen -


Code.Cong er t of PS RAB
assignment
failure per
cell

VS.RAB.FailEstPs. numb Measuremen -


ULCE.Cong er t of PS RAB
assignment
failure per
cell

VS.RAB.FailEstPs. numb Measuremen -


DLCE.Cong er t of PS RAB
assignment
failure per
cell

VS.RAB.FailEstPs.I numb Measuremen -


UB.Band er t of PS RAB
assignment
failure per
cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 717


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.FailEstabP numb Measuremen [VS.RAB.FailEstPS.Unsp]-


S.Unsp.Other er t of PS RAB [VS.RAB.FailEstPs.Power.Co
assignment ng]-
setup per cell [VS.RAB.FailEstPs.Code.Con
g]-
[VS.RAB.FailEstPs.ULCE.Co
ng]-
[VS.RAB.FailEstPs.DLCE.Co
ng]-
[VS.RAB.FailEstPs.IUB.Band
]

VS.RAB.FlEstPS.R numb Measuremen [VS.RAB.FailEstPS.RNL]-


NL.Other er t of PS RAB [VS.RAB.FailEstPS.RIPFail]-
assignment [VS.RAB.FailEstPS.Par]-
failure per [VS.RAB.FailEstPS.Relo]-
cell [VS.RAB.FailEstPS.Unsp]

VS.RAB.FailEstabP numb Measuremen (([VS.RAB.AttEstabPS.Conv]


S.Other.Cell er t of PS RAB +[VS.RAB.AttEstabPS.Str]+
assignment [VS.RAB.AttEstabPS.Inter]+
setup per cell [VS.RAB.AttEstabPS.Bkg])-
([VS.RAB.SuccEstabPS.Conv
]+[VS.RAB.SuccEstabPS.Str]
+[VS.RAB.SuccEstabPS.In-
ter]+
[VS.RAB.SuccEstabPS.Bkg]))
-[VS.RAB.FailEstPS.TNL]-
[VS.RAB.FailEstPS.RNL]

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

20.4.5 RRC Fail Report

Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 718


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

NE Type
RNC

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

RRC Fail VS.RRC.FailConnE times RRC [VS.RRC.AttConnEstab.Cell]-


stab.Cell connection [RRC.SuccConnEstab.sum]
setup
measurement
per cell

VS.RRC.AttConnEs times RRC -


tab.Cell connection
setup
measurement
per cell

VS.RRC.Rej.RL.Fai times RRC -


l connection
reject
measurement
per cell

VS.RRC.Rej.TNL.F times RRC -


ail connection
reject
measurement
per cell

VS.RRC.Rej.Power. times RRC -


Cong connection
reject
measurement
per cell

VS.RRC.Rej.UL.CE times RRC -


.Cong connection
reject
measurement
per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 719


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 20 UMTS RAN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RRC.Rej.DL.CE times RRC -


.Cong connection
reject
measurement
per cell

VS.RRC.Rej.Code.C times RRC -


ong connection
reject
measurement
per cell

VS.RRC.Rej.Other. times RRC [RRC.FailConnEstab.Cong]-


Cong connection [VS.RRC.Rej.Power.Cong]-
reject [VS.RRC.Rej.Code.Cong]-
measurement [VS.RRC.Rej.UL.CE.Cong]-
per cell [VS.RRC.Rej.DL.CE.Cong]

RRC.FailConnEstab. times RRC -


NoReply connection
reject
measurement
per cell

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 720


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

21 UMTS RAN Professional Report

About This Chapter

21.1 Cluster Daily Report

21.2 Cluster Weekly Report

21.3 Monitoring Report

21.4 Network shift Report

21.5 RNC Daily Report

21.6 RNC Monthly Report

21.7 RNC Weekly Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 721


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

21.1 Cluster Daily Report

21.1.1 All Service KPI Report

Report Type
Simple Report

NE Type
RNC

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Traffic VS.AMR.Ctrl.DL12. numb Measuremen -


2 er t of RB
Procedure
per cell

VS.RB.DLConvCS. numb Measuremen -


64 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


64 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


128 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


144 er t of RB
Procedure
per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 722


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RB.DLInterPS. numb Measuremen -


384 er t of RB
Procedure
per cell

VS.RB.DLBkgPS.64 numb Measuremen -


er t of RB
Procedure
per cell

VS.RB.DLBkgPS. numb Measuremen -


128 er t of RB
Procedure
per cell

VS.RB.DLBkgPS. numb Measuremen -


144 er t of RB
Procedure
per cell

VS.RB.DLBkgPS. numb Measuremen -


384 er t of RB
Procedure
per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 723


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Access VS.RRC.SuccConn % RRC ([RRC.SuccConnEstab.Og-


Estab.Service.Cell.R connection ConvCall]+
ate setup [RRC.SuccConnEstab.OrgStr-
measurement Call]+
per cell [RRC.SuccConnEstab.OrgItr-
Call]+
[RRC.SuccConnEstab.OrgBk
gCall]+
[RRC.SuccConnEstab.Org-
SubCall]+
[RRC.SuccConnEstab.TmCon
vCall]+
[RRC.SuccConnEstab.TmStr
Call]+
[RRC.SuccConnEstab.TmItr-
Call]+
[RRC.SuccConnEstab.TmBkg
Call]+
[RRC.SuccConnEstab.Emg-
Call]+
[RRC.SuccConnEstab.Un-
kown]+
[RRC.SuccConnEstab.OgHhP
rSig]+
[RRC.SuccConnEstab.OgLwP
rSig]+
[RRC.SuccConnEstab.CallRe-
Est]+
[RRC.SuccConnEstab.TmHhP
rSig]+
[RRC.SuccConnEstab.TmLw
PrSig])/
([RRC.AttConnEstab.Org-
ConvCall]+
[RRC.AttConnEstab.OrgStr-
Call]+
[RRC.AttConnEstab.OrgInter-
Call]+
[RRC.AttConnEstab.OrgBkg-
Call]+
[RRC.AttConnEstab.OgSub-
Call]+
[RRC.AttConnEstab.TmConv
Call]+
[RRC.AttConnEstab.TmStrCa
ll]+
[RRC.AttConnEstab.TmInter-

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 724


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Call]+
[RRC.AttConnEstab.TmBkgC
all]+
[RRC.AttConnEstab.Emg-
Call]+
[RRC.AttConnEstab.Un-
known]+
[RRC.AttConnEstab.OgHhPr-
Sig]+
[RRC.AttConnEstab.OgLwPr-
Sig]+
[RRC.AttConnEstab.CallRe-
Est]+
[RRC.AttConnEstab.TmHhPr
Sig]+
[RRC.AttConnEstab.TmLwPr
Sig])*{100.00}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 725


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RRC.SuccConn none RRC [RRC.SuccConnEstab.Og-


Estab.Service.Cell connection ConvCall]+
setup [RRC.SuccConnEstab.OrgStr-
measurement Call]+
per cell [RRC.SuccConnEstab.OrgItr-
Call]+
[RRC.SuccConnEstab.OrgBk
gCall]+
[RRC.SuccConnEstab.Org-
SubCall]+
[RRC.SuccConnEstab.TmCon
vCall]+
[RRC.SuccConnEstab.TmStr
Call]+
[RRC.SuccConnEstab.TmItr-
Call]+
[RRC.SuccConnEstab.TmBkg
Call]+
[RRC.SuccConnEstab.Emg-
Call]+
[RRC.SuccConnEstab.Un-
kown]+
[RRC.SuccConnEstab.OgHhP
rSig]+
[RRC.SuccConnEstab.OgLwP
rSig]+
[RRC.SuccConnEstab.CallRe-
Est]+
[RRC.SuccConnEstab.TmHhP
rSig]+
[RRC.SuccConnEstab.TmLw
PrSig]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 726


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RRC.AttConnEs none RRC [RRC.AttConnEstab.Org-


tab.Service.Cell connection ConvCall]+
setup [RRC.AttConnEstab.OrgStr-
measurement Call]+
per cell [RRC.AttConnEstab.OrgInter-
Call]+
[RRC.AttConnEstab.OrgBkg-
Call]+
[RRC.AttConnEstab.OgSub-
Call]+
[RRC.AttConnEstab.TmConv
Call]+
[RRC.AttConnEstab.TmStrCa
ll]+
[RRC.AttConnEstab.TmInter-
Call]+
[RRC.AttConnEstab.TmBkgC
all]+
[RRC.AttConnEstab.Emg-
Call]+
[RRC.AttConnEstab.Un-
known]+
[RRC.AttConnEstab.OgHhPr-
Sig]+
[RRC.AttConnEstab.OgLwPr-
Sig]+
[RRC.AttConnEstab.CallRe-
Est]+
[RRC.AttConnEstab.TmHhPr
Sig]+
[RRC.AttConnEstab.TmLwPr
Sig]

VS.RRC.SuccConn % RRC ([RRC.SuccConnEstab.IRAT-


Estab.Other.Cell.Rat connection CelRes]+
e setup [RRC.SuccConnEstab.IRATC
measurement CO]+
per cell [RRC.SuccConnEstab.Reg]+
[RRC.SuccConnEstab.De-
tach])/
([RRC.AttConnEstab.IRAT-
CelRes]+
[RRC.AttConnEstab.IRATC-
CO]+
[RRC.AttConnEstab.Reg]+
[RRC.AttConnEstab.Detach])
*{100.00}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 727


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RRC.SuccConn none RRC [RRC.SuccConnEstab.IRAT-


Estab.Other.Cell connection CelRes]+
setup [RRC.SuccConnEstab.IRATC
measurement CO]+
per cell [RRC.SuccConnEstab.Reg]+
[RRC.SuccConnEstab.Detach]

VS.RRC.AttConnEs none RRC [RRC.AttConnEstab.IRAT-


tab.Other.Cell connection CelRes]+
setup [RRC.AttConnEstab.IRATC-
measurement CO]+
per cell [RRC.AttConnEstab.Reg]+
[RRC.AttConnEstab.Detach]

VS.RAB.SuccEstab % Measuremen [VS.RAB.SuccEstab.AMR]/


CS.AMR.Cell.Rate t of CS RAB [VS.RAB.AttEstab.AMR]*
assignment {100.00}
setup per cell

VS.RAB.SuccEstab. numb Measuremen -


AMR er t of CS RAB
assignment
setup per cell

VS.RAB.AttEstab.A numb Measuremen -


MR er t of CS RAB
assignment
setup per cell

VS.RAB.SuccEstab % Measuremen [VS.RAB.SuccEstCS.Conv.


CS.Conv. t of CS RAB 64]/[VS.RAB.AttEstCS.Conv.
64.Cell.Rate assignment 64]*{100.00}
setup per cell

VS.RAB.SuccEstCS numb Measuremen -


.Conv.64 er t of CS RAB
assignment
setup per cell

VS.RAB.AttEstCS. numb Measuremen -


Conv.64 er t of CS RAB
assignment
setup per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 728


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.SuccEstab % Measuremen ([VS.RAB.SuccEstabPS.Conv


PS.Cell.Rate t of PS RAB ]+[VS.RAB.SuccEstabPS.Str]
assignment +[VS.RAB.SuccEstabPS.In-
setup per cell ter]+
[VS.RAB.SuccEstabPS.Bkg])/
([VS.RAB.AttEstabPS.Conv]
+[VS.RAB.AttEstabPS.Str]+
[VS.RAB.AttEstabPS.Inter]+
[VS.RAB.AttEstabPS.Bkg])*
{100.00}

VS.RAB.SuccEstPS. none Measuremen [VS.RAB.SuccEstabPS.Conv]


Cell t of PS RAB +[VS.RAB.SuccEstabPS.Str]+
assignment [VS.RAB.SuccEstabPS.Inter]
setup per cell +[VS.RAB.SuccEstabPS.Bkg]

VS.RAB.AttEstabPS numb Measuremen [VS.RAB.AttEstabPS.Conv]+


.Cell er t of PS RAB [VS.RAB.AttEstabPS.Str]+
assignment [VS.RAB.AttEstabPS.Inter]+
setup per cell [VS.RAB.AttEstabPS.Bkg]

HO VS.SHO.Factor.RL. none Soft (([VS.SHO.AS.1RL]+


Cell Handover [VS.SHO.AS.2RL]+
Measuremen [VS.SHO.AS.3RL]+
t per cell [VS.SHO.AS.4RL]+
[VS.SHO.AS.5RL]+
[VS.SHO.AS.6RL])/
([VS.SHO.AS.1RL]+
[VS.SHO.AS.2RL]/{2}+
[VS.SHO.AS.3RL]/{3}+
[VS.SHO.AS.4RL]/{4}+
[VS.SHO.AS.5RL]/{5}+
[VS.SHO.AS.6RL]/{6}))-{1}

VS.SHO.Success.Ce % Soft ([SHO.SuccRLAddUESide]+


ll.Rate Handover [SHO.SuccRLDelUESide])/
Measuremen ([SHO.AttRLAddUESide]+
t per cell [SHO.AttRLDelUESide])*
{100.00}

VS.SHO.SuccUESid none Soft [SHO.SuccRLAddUESide]+


e.Cell Handover [SHO.SuccRLDelUESide]
Measuremen
t per cell

VS.SHO.AttUESide. none Soft [SHO.AttRLAddUESide]+


Cell Handover [SHO.AttRLDelUESide]
Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 729


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.HHO.InterFreq. % Hard [VS.HHO.InterFreq.SuccOut]/


Out.Cell.Rate Handover [VS.HHO.InterFreq.AttOut]*
Measuremen {100.00}
t per cell

VS.HHO.InterFreq.S times Hard -


uccOut Handover
Measuremen
t per cell

VS.HHO.InterFreq. times Hard -


AttOut Handover
Measuremen
t per cell

VS.IRATHO.SuccO % InterRAT [IRATHO.SuccOutCS]/


utCS.Cell.Rate Handover [IRATHO.AttOutCS]*
Measuremen {100.00}
t per cell

IRATHO.SuccOutC times InterRAT -


S Handover
Measuremen
t per cell

IRATHO.AttOutCS times InterRAT -


Handover
Measuremen
t per cell

VS.IRATHO.SuccO % InterRAT [IRATHO.SuccOutPSU-


utPSUNTRAN.Cell. Handover TRAN]/[IRATHO.AttOut-
Rate Measuremen PSUTRAN]*{100.00}
t per cell

IRATHO.SuccOut- times InterRAT -


PSUTRAN Handover
Measuremen
t per cell

IRATHO.AttOut- times InterRAT -


PSUTRAN Handover
Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 730


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

CDR VS.CS.AMR.Call.D % Measuremen [VS.RAB.Loss.CS.AMR]/


rop.Cell.Rate t of RAB ([VS.RAB.Loss.CS.AMR]+
release [VS.RAB.Loss.CS.Norm.AM
triggered by R])*{100.00}
UTRAN per
cell

VS.CS.AMR.Call.D none Measuremen [VS.RAB.Loss.CS.AMR]


rop.Cell t of RAB
release
triggered by
UTRAN per
cell

VS.CS.AMR.Re- none Measuremen [VS.RAB.Loss.CS.AMR]+


lease t of RAB [VS.RAB.Loss.CS.Norm.AM
release R]
triggered by
UTRAN per
cell

VS.CS.VP.Call.Dro % Measuremen [VS.RAB.Loss.CS.Conv64K]/


p.Cell.Rate t of RAB ([VS.RAB.Loss.CS.Conv64K]
release +[VS.Norm.Rel.CS.Conv.RB.
triggered by 64])*{100.00}
UTRAN per
cell

VS.CS.VP.Call.Dro none Measuremen [VS.RAB.Loss.CS.Conv64K]


p.Cell t of RAB
release
triggered by
UTRAN per
cell

VS.CS.VP.Release none Measuremen [VS.RAB.Loss.CS.Conv64K]


t of RAB +[VS.Norm.Rel.CS.Conv.RB.
release 64]
triggered by
UTRAN per
cell

VS.PS.Call.Drop.Ce % Measuremen ([VS.RAB.Loss.PS.RF]+


ll.Rate t of RAB [VS.RAB.Loss.PS.Abnorm])/
release ([VS.RAB.Loss.PS.RF]+
triggered by [VS.RAB.Loss.PS.Abnorm]+
UTRAN per [VS.RAB.Loss.PS.Norm])*
cell {100.00}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 731


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.PS.Call.Drop.Ce numb Measuremen [VS.RAB.Loss.PS.RF]+


ll er t of RAB [VS.RAB.Loss.PS.Abnorm]
release
triggered by
UTRAN per
cell

VS.RAB.Release.PS none Measuremen [VS.RAB.Loss.PS.RF]+


.Cell t of RAB [VS.RAB.Loss.PS.Abnorm]+
release [VS.RAB.Loss.PS.Norm]
triggered by
UTRAN per
cell

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.1.2 Call TopN Report

Report Type
Simple Report

NE Type
RNC

Object Type
UCell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 732


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

CS Call VS.CS.Call.Drop.Ce numb Measuremen [VS.RAB.Loss.CS.RF]+


Drop ll er t of RAB [VS.RAB.Loss.CS.Abnorm]
Cells release
triggered by
UTRAN per
cell

VS.CS.RAB.Release none Measuremen [VS.RAB.Loss.CS.RF]+


t of RAB [VS.RAB.Loss.CS.Abnorm]+
release [VS.RAB.Loss.CS.Norm]
triggered by
UTRAN per
cell

VS.RAB.RelReqCS. numb Measuremen -


OM er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.RelReqCS. numb Measuremen -


RABPreempt er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.RelReqCS. numb Measuremen -


UTRANgen er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.CS.R numb Measuremen -


F.RLCRst er t of RAB
release
triggered by
UTRAN per
cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 733


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.Loss.CS.R numb Measuremen -


F.ULSync er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.CS.R numb Measuremen -


F.UuNoReply er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.CS.R numb Measuremen -


F.Oth er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.CS.A numb Measuremen -


al2Loss er t of RAB
release
triggered by
UTRAN per
cell

VS.Call.Drop.CS.Ot numb Measuremen [VS.RAB.Loss.CS.Abnorm]-


her er t of RAB [VS.RAB.RelReqCS.OM]-
release [VS.RAB.RelReqCS.UTRAN
triggered by gen]-
UTRAN per [VS.RAB.RelReqCS.RAB-
cell Preempt]-
[VS.RAB.Loss.CS.Aal2Loss]

VP Call VS.CS.VP.Call.Dro none Measuremen [VS.RAB.Loss.CS.Conv64K]


Drops p.Cell t of RAB
release
triggered by
UTRAN per
cell

AMR VS.CS.AMR.Call.D none Measuremen [VS.RAB.Loss.CS.AMR]


Call rop.Cell t of RAB
Drops release
triggered by
UTRAN per
cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 734


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

PS Drop VS.PS.Call.Drop.Ce numb Measuremen [VS.RAB.Loss.PS.RF]+


Cells ll er t of RAB [VS.RAB.Loss.PS.Abnorm]
release
triggered by
UTRAN per
cell

VS.PS.RAB.Release none Measuremen [VS.RAB.Loss.PS.RF]+


t of RAB [VS.RAB.Loss.PS.Abnorm]+
release [VS.RAB.Loss.PS.Norm]
triggered by
UTRAN per
cell

VS.RAB.RelReqPS. numb Measuremen -


OM er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.RelReqPS. numb Measuremen -


RABPreempt er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.PS.R numb Measuremen -


F.RLCRst er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.PS.R numb Measuremen -


F.ULSync er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.PS.R numb Measuremen -


F.UuNoReply er t of RAB
release
triggered by
UTRAN per
cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 735


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.Loss.PS.R numb Measuremen -


F.Oth er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.PS.G numb Measuremen -


TPULoss er t of RAB
release
triggered by
UTRAN per
cell

VS.Call.Drop.PS.Ot numb Measuremen [VS.RAB.Loss.PS.Abnorm]-


her er t of RAB [VS.RAB.RelReqPS.OM]-
release [VS.RAB.RelReqPS.RAB-
triggered by Preempt]-
UTRAN per [VS.RAB.Loss.PS.GTPU-
cell Loss]

RRC Fail VS.RRC.FailConnE times RRC [VS.RRC.AttConnEstab.Cell]-


stab.Cell connection [RRC.SuccConnEstab.sum]
setup
measurement
per cell

VS.RRC.AttConEst. none RRC [VS.RRC.AttConEst.DCH]+


Cell connection [VS.RRC.AttConEst.CCH]
setup
measurement
per cell

VS.RRC.Rej.RL.Fai times RRC -


l connection
reject
measurement
per cell

VS.RRC.Rej.TNL.F times RRC -


ail connection
reject
measurement
per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 736


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RRC.Rej.Power. times RRC -


Cong connection
reject
measurement
per cell

VS.RRC.Rej.UL.CE times RRC -


.Cong connection
reject
measurement
per cell

VS.RRC.Rej.DL.CE times RRC -


.Cong connection
reject
measurement
per cell

VS.RRC.Rej.Code.C times RRC -


ong connection
reject
measurement
per cell

VS.RRC.Rej.Other. times RRC [RRC.FailConnEstab.Cong]-


Cong connection [VS.RRC.Rej.Power.Cong]-
reject [VS.RRC.Rej.Code.Cong]-
measurement [VS.RRC.Rej.UL.CE.Cong]-
per cell [VS.RRC.Rej.DL.CE.Cong]

RRC.FailConnEstab. times RRC -


NoReply connection
reject
measurement
per cell

CS RAB VS.RAB.FailEstabC numb Measuremen [VS.RAB.AttEstabCS.Conv]+


FAIL S.Cell er t of CS RAB [VS.RAB.AttEstabCS.Str]-
assignment [VS.RAB.SuccEstabCS.Conv]
setup per cell -[VS.RAB.SuccEstabCS.Str]

VS.RAB.AttEstabC numb Measuremen [VS.RAB.AttEstabCS.Conv]+


S.Cell er t of CS RAB [VS.RAB.AttEstabCS.Str]
assignment
setup per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 737


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.FailEstabC numb Measuremen -


S.TNL er t of CS RAB
assignment
failure per
cell

VS.RAB.FailEstCS. numb Measuremen -


Relo er t of CS RAB
assignment
failure per
cell

VS.RAB.FailEstCS. numb Measuremen -


RIPFail er t of CS RAB
assignment
failure per
cell

VS.RAB.FailEstCs. numb Measuremen -


Power.Cong er t of CS RAB
assignment
failure per
cell

VS.RAB.FailEstCs. numb Measuremen -


ULCE.Cong er t of CS RAB
assignment
failure per
cell

VS.RAB.FailEstCs. numb Measuremen -


DLCE.Cong er t of CS RAB
assignment
failure per
cell

VS.RAB.FailEstCs. numb Measuremen -


Code.Cong er t of CS RAB
assignment
failure per
cell

VS.RAB.FailEstab. numb Measuremen -


CS.DLIUBBand.Co er t of CS RAB
ng assignment
failure per
cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 738


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.FailEstab. numb Measuremen -


CS.ULIUBBand.Co er t of CS RAB
ng assignment
failure per
cell

VS.RAB.FailEstabC numb Measuremen [VS.RAB.FailEstCS.Unsp]-


S.Unsp.Other er t of CS RAB [VS.RAB.FailEstabCS.Cong]
assignment
failure per
cell

VS.RAB.FailEstabC numb Measuremen [VS.RAB.FailEstabCS.RNL]-


S.RNL.Other er t of CS RAB [VS.RAB.FailEstCS.Relo]-
assignment [VS.RAB.FailEstCS.RIPFail]-
failure per [VS.RAB.FailEstabCS.Cong]
cell

VS.RAB.FailEstabC none Measuremen ([VS.RAB.AttEstabCS.Conv]


S.other.CELL t of CS RAB +[VS.RAB.AttEstabCS.Str]-
assignment [VS.RAB.SuccEstabCS.Conv]
setup per cell -[VS.RAB.SuccEstabCS.Str])-
[VS.RAB.FailEstabCS.RNL]-
[VS.RAB.FailEstabCS.TNL]

PS RAB VS.RAB.FailEstabP numb Measuremen ([VS.RAB.AttEstabPS.Conv]


FAIL S.Cell er t of PS RAB +[VS.RAB.AttEstabPS.Str]+
assignment [VS.RAB.AttEstabPS.Inter]+
setup per cell [VS.RAB.AttEstabPS.Bkg])-
([VS.RAB.SuccEstabPS.Conv
]+[VS.RAB.SuccEstabPS.Str]
+[VS.RAB.SuccEstabPS.In-
ter]+
[VS.RAB.SuccEstabPS.Bkg])

VS.RAB.AttEstabPS numb Measuremen [VS.RAB.AttEstabPS.Conv]+


.Cell er t of PS RAB [VS.RAB.AttEstabPS.Str]+
assignment [VS.RAB.AttEstabPS.Inter]+
setup per cell [VS.RAB.AttEstabPS.Bkg]

VS.RAB.FailEstPS. numb Measuremen -


TNL er t of PS RAB
assignment
failure per
cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 739


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.FailEstPS. numb Measuremen -


RIPFail er t of PS RAB
assignment
failure per
cell

VS.RAB.FailEstPS. numb Measuremen -


Par er t of PS RAB
assignment
failure per
cell

VS.RAB.FailEstPS. numb Measuremen -


Relo er t of PS RAB
assignment
failure per
cell

VS.RAB.FailEstPs.P numb Measuremen -


ower.Cong er t of PS RAB
assignment
failure per
cell

VS.RAB.FailEstPs. numb Measuremen -


Code.Cong er t of PS RAB
assignment
failure per
cell

VS.RAB.FailEstPs. numb Measuremen -


ULCE.Cong er t of PS RAB
assignment
failure per
cell

VS.RAB.FailEstPs. numb Measuremen -


DLCE.Cong er t of PS RAB
assignment
failure per
cell

VS.RAB.FailEstab.P numb Measuremen -


S.DLIUBBand.Cong er t of PS RAB
assignment
failure per
cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 740


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.FailEstab.P numb Measuremen -


S.ULIUBBand.Cong er t of PS RAB
assignment
failure per
cell

VS.RAB.FailEstabP none Measuremen [VS.RAB.FailEstPS.Unsp]-


S.Unsp.Other t of PS RAB [VS.RAB.FailEstPs.Power.Co
assignment ng]-
failure per [VS.RAB.FailEstPs.Code.Con
cell g]-
[VS.RAB.FailEstPs.ULCE.Co
ng]-
[VS.RAB.FailEstPs.DLCE.Co
ng]-
[VS.RAB.FailEstab.PS.DLIU
BBand.Cong]-
[VS.RAB.FailEstab.PS.ULIU
BBand.Cong]

VS.RAB.FlEstPS.R numb Measuremen [VS.RAB.FailEstPS.RNL]-


NL.Other er t of PS RAB [VS.RAB.FailEstPS.RIPFail]-
assignment [VS.RAB.FailEstPS.Par]-
failure per [VS.RAB.FailEstPS.Relo]-
cell [VS.RAB.FailEstPS.Unsp]

VS.RAB.FailEstabP numb Measuremen (([VS.RAB.AttEstabPS.Conv]


S.Other.Cell er t of PS RAB +[VS.RAB.AttEstabPS.Str]+
assignment [VS.RAB.AttEstabPS.Inter]+
setup per cell [VS.RAB.AttEstabPS.Bkg])-
([VS.RAB.SuccEstabPS.Conv
]+[VS.RAB.SuccEstabPS.Str]
+[VS.RAB.SuccEstabPS.In-
ter]+
[VS.RAB.SuccEstabPS.Bkg]))
-[VS.RAB.FailEstPS.TNL]-
[VS.RAB.FailEstPS.RNL]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 741


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.1.3 HO TopN Report

Report Type
Simple Report

NE Type
RNC

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

SHO VS.SHO.Fail.Cell none Soft [SHO.AttRLAddUESide]+


FAIL Handover [SHO.AttRLDelUESide]-
Measuremen [SHO.SuccRLAddUESide]-
t per cell [SHO.SuccRLDelUESide]

VS.SHO.AttUESide. none Soft [SHO.AttRLAddUESide]+


Cell Handover [SHO.AttRLDelUESide]
Measuremen
t per cell

SHO.FailRLAddUE times Soft -


Side.CfgUnsup Handover
Measuremen
t per cell

SHO.FailRLAddUE times Soft -


Side.Isr Handover
Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 742


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

SHO.FailRLAddUE times Soft -


Side.InvCfg Handover
Measuremen
t per cell

SHO.FailRLAddUE times Soft -


Side.NoReply Handover
Measuremen
t per cell

VS.SHO.Fail.Other. none Soft ([SHO.AttRLAddUESide]+


Cell Handover [SHO.AttRLDelUESide]-
Measuremen [SHO.SuccRLAddUESide]-
t per cell [SHO.SuccRLDelUESide])-
[SHO.FailRLAddUESide.Cfg
Unsup]-
[SHO.FailRLAddUESide.Isr]-
[SHO.FailRLAddUESide.Inv
Cfg]-
[SHO.FailRLAddUESide.No
Reply]

InterFRe VS.HHO.InterFreq.F none Hard [VS.HHO.InterFreq.AttOut]-


quest ailOut Handover [VS.HHO.InterFreq.SuccOut]
HHO Measuremen
Fail t per cell

VS.HHO.InterFreq. times Hard -


AttOut Handover
Measuremen
t per cell

VS.HHO.InterFreqO times Hard -


ut.CfgUnsupp Handover
Measuremen
t per cell

VS.HHO.InterFreqO times Hard -


ut.PyhChFail Handover
Measuremen
t per cell

VS.HHO.InterFreqO times Hard -


ut.FailUSR Handover
Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 743


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.HHO.InterFreqO times Hard -


ut.CellUpdt Handover
Measuremen
t per cell

VS.HHO.InterFreqO times Hard -


ut.CfgInvalid Handover
Measuremen
t per cell

VS.HHO.InterFreqO times Hard -


ut.NoReply Handover
Measuremen
t per cell

VS.HHO.InterFreq.F none Hard ([VS.HHO.InterFreq.AttOut]-


ailOther Handover [VS.HHO.InterFreq.Suc-
Measuremen cOut])-
t per cell [VS.HHO.InterFreqOut.CfgU
nsupp]-
[VS.HHO.InterFreqOut.PyhC
hFail]-
[VS.HHO.InterFreqOut.Fail-
USR]-
[VS.HHO.InterFreqOut.Cel-
lUpdt]-
[VS.HHO.InterFreqOut.CfgIn
valid]-
[VS.HHO.InterFreqOut.NoRe
ply]

CS VS.IRATHO.Fail- none InterRAT [IRATHO.AttOutCS]-


InterRA OutCS Handover [IRATHO.SuccOutCS]
T HHO Measuremen
FAIL t per cell

IRATHO.AttOutCS times InterRAT -


Handover
Measuremen
t per cell

IRATHO.FailOutCS times InterRAT -


.CfgUnsupp Handover
Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 744


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

IRATHO.FailOutCS times InterRAT -


.PhyChFail Handover
Measuremen
t per cell

VS.IRATHO.FailOu none InterRAT ([IRATHO.AttOutCS]-


tCS.Other Handover [IRATHO.SuccOutCS])-
Measuremen [IRATHO.FailOutCS.CfgUn-
t per cell supp]-
[IRATHO.FailOutCS.PhyCh-
Fail]

PS VS.IRATHO.FailOu none InterRAT [IRATHO.AttOutPSUTRAN]-


InterRA tPSUTRAN.Cell Handover [IRATHO.SuccOutPSU-
T HHO Measuremen TRAN]
FAIL t per cell

IRATHO.AttOut- times InterRAT -


PSUTRAN Handover
Measuremen
t per cell

IRATHO.FailOutPS times InterRAT -


UTRAN.CfgUnsupp Handover
Measuremen
t per cell

IRATHO.FailOutPS times InterRAT -


UTRAN.PhyChFail Handover
Measuremen
t per cell

VS.IRATHO.FailOu none InterRAT [IRATHO.AttOutPSUTRAN]-


tPSUTRAN.Other Handover [IRATHO.SuccOutPSU-
Measuremen TRAN]-
t per cell [IRATHO.FailOutPSUTRAN.
CfgUnsupp]-
[IRATHO.FailOutPSUTRAN.
PhyChFail]

HSDPA VS.HSDPA.ServCel none HSDPA [VS.HSDPA.HHO.AttOutIn-


HHO lChg.HHO.IntraFreq Measuremen traFreq]-
IntraFRe .NoChR.Fail t per cell [VS.HSDPA.HHO.SuccOu-
quest Fail tIntraFreq]

VS.HSDPA.HHO.At times HSDPA -


tOutIntraFreq Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 745


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

HSDPA VS.HSDPA.ServCel none HSDPA [VS.HSDPA.HHO.AttOutIn-


HHO lChg.HHO.InterFreq Measuremen terFreq]-
InterFRe .NoChR.Fail t per cell [VS.HSDPA.HHO.SuccOu-
quest Fail tInterFreq]

VS.HSDPA.HHO.At times HSDPA -


tOutInterFreq Measuremen
t per cell

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.1.4 HSDPA KPI Report

Report Type
Simple Report

NE Type
RNC

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

HSDPA VS.HSDPA.MeanC none HSDPA [VS.HSDPA.MeanChThrough


Traffic hThroughput.Total- Measuremen put.TotalBytes]/({1024}*
MBytes t per cell {1024})

VS.HSDPA.UE.Mea numb HSDPA -


n.Cell er Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 746


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.HSDPA.MeanC none HSDPA ([VS.HSDPA.MeanChThroug


hThroughput.To- Measuremen hput.TotalBytes]*{8.0}/
talMBps t per cell ({1024.0}*{1024.0}))/({GP}*
{60})

HSDPA VS.HSDPA.RAB.Su % HSDPA [VS.HSDPA.RAB.SuccEs-


Access ccEstab.Rate Measuremen tab]/[VS.HSDPA.RAB.AttEs-
t per cell tab]*{100.00}

VS.HSDPA.RAB.Su times HSDPA -


ccEstab Measuremen
t per cell

VS.HSDPA.RAB.At times HSDPA -


tEstab Measuremen
t per cell

HSDPA VS.HSDPA.ServCel % HSDPA [VS.HSDPA.SHO.CellChg.Su


HO lChg.Succ.Rate Measuremen ccOut]/
t per cell [VS.HSDPA.SHO.CellChg.At
tOut]*{100.00}

VS.HSDPA.SHO.Ce times HSDPA -


llChg.SuccOut Measuremen
t per cell

VS.HSDPA.SHO.Ce times HSDPA -


llChg.AttOut Measuremen
t per cell

VS.HSDPA.HHO.In % HSDPA [VS.HSDPA.HHO.SuccOu-


traFreq.NoChR.Succ Measuremen tIntraFreq]/
.Rate t per cell [VS.HSDPA.HHO.AttOutIn-
traFreq]*{100.00}

VS.HSDPA.HHO.S times HSDPA -


uccOutIntraFreq Measuremen
t per cell

VS.HSDPA.HHO.At times HSDPA -


tOutIntraFreq Measuremen
t per cell

VS.HSDPA.HHO.In % HSDPA [VS.HSDPA.HHO.SuccOu-


terFreq.NoChR.Succ Measuremen tInterFreq]/
.Rate t per cell [VS.HSDPA.HHO.AttOutIn-
terFreq]*{100.00}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 747


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.HSDPA.HHO.S times HSDPA -


uccOutInterFreq Measuremen
t per cell

VS.HSDPA.HHO.At times HSDPA -


tOutInterFreq Measuremen
t per cell

VS.HSDPA.ChR.HS % HSDPA [VS.HSDPA.ChR.HSDSCHto


DSCHtoDCH.Succ. Measuremen DCH]/
Rate t per cell [VS.HSDPA.ChR.HSDSCHto
DCH.Att]*{100.00}

VS.HSDPA.ChR.HS times HSDPA -


DSCHtoDCH Measuremen
t per cell

VS.HSDPA.ChR.HS times HSDPA -


DSCHtoDCH.Att Measuremen
t per cell

VS.HSDPA.ChR.D % HSDPA [VS.HSDPA.ChR.DCHtoHSD


CHtoHSDSCH.Succ Measuremen SCH]/
.Rate t per cell [VS.HSDPA.ChR.DCHtoHSD
SCH.Att]*{100.00}

VS.HSDPA.ChR.D times HSDPA -


CHtoHSDSCH Measuremen
t per cell

VS.HSDPA.ChR.D times HSDPA -


CHtoHSDSCH.Att Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 748


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

HSDPA VS.HSDPA.RAB.A % HSDPA ([VS.HSDPA.RAB.Loss.Abn


CDR bnormRel.Rate Measuremen orm.NonRF]+
t per cell [VS.HSDPA.RAB.Loss.RF])/
([VS.HSDPA.RAB.Loss.In-
Activity]+
[VS.HSDPA.RAB.Loss.Abno
rm.NonRF]+
[VS.HSDPA.RAB.Loss.RF]+
[VS.HSDPA.RAB.Loss.Norm
]+
[VS.HSDPA.ChR.HSDSCHto
DCH]+
[VS.HSDPA.ChR.HSDSCHto
FACH]+
[VS.HSDPA.HHO.H2D.Suc-
cOutIntraFreq]+
[VS.HSDPA.HHO.H2D.Suc-
cOutInterFreq])*{100.00}

VS.HSDPA.RAB.A none HSDPA [VS.HSDPA.RAB.Loss.Abno


bnormRel Measuremen rm.NonRF]+
t per cell [VS.HSDPA.RAB.Loss.RF]

VS.HSDPA.RAB.Re none HSDPA [VS.HSDPA.RAB.Loss.InAc-


l Measuremen tivity]+
t per cell [VS.HSDPA.RAB.Loss.Abno
rm.NonRF]+
[VS.HSDPA.RAB.Loss.RF]+
[VS.HSDPA.RAB.Loss.Norm
]+
[VS.HSDPA.ChR.HSDSCHto
DCH]+
[VS.HSDPA.ChR.HSDSCHto
FACH]+
[VS.HSDPA.HHO.H2D.Suc-
cOutIntraFreq]+
[VS.HSDPA.HHO.H2D.Suc-
cOutInterFreq]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 749


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.1.5 HSDPA TopN Report

Report Type
Simple Report

NE Type
RNC

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

HSDPA VS.HSDPA.RAB.Fa none HSDPA [VS.HSDPA.RAB.AttEstab]-


RAB Fail ilEstab Measuremen [VS.HSDPA.RAB.SuccEstab]
t per cell

VS.HSDPA.RAB.At times HSDPA -


tEstab Measuremen
t per cell

VS.HSDPA.MACD- times HSDPA -


FailStpPerCell Measuremen
t per cell

VS.HSDPA.MAC- none HSDPA [VS.HSDPA.MACDSuccStp-


DAttStpPerCell Measuremen PerCell]+
t per cell [VS.HSDPA.MACDFailStp-
PerCell]

HSDPA VS.HSDPA.RAB.A none HSDPA [VS.HSDPA.RAB.Loss.Abno


RAB bnormRel Measuremen rm.NonRF]+
Abnorm t per cell [VS.HSDPA.RAB.Loss.RF]
Rel

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 750


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.HSDPA.RAB.Re none HSDPA [VS.HSDPA.RAB.Loss.InAc-


l Measuremen tivity]+
t per cell [VS.HSDPA.RAB.Loss.Abno
rm.NonRF]+
[VS.HSDPA.RAB.Loss.RF]+
[VS.HSDPA.RAB.Loss.Norm
]+
[VS.HSDPA.ChR.HSDSCHto
DCH]+
[VS.HSDPA.ChR.HSDSCHto
FACH]+
[VS.HSDPA.HHO.H2D.Suc-
cOutIntraFreq]+
[VS.HSDPA.HHO.H2D.Suc-
cOutInterFreq]

VS.HSDPA.MeanC none HSDPA ({8}*


hThroughput.NEW Measuremen [VS.HSDPA.MeanChThrough
t per cell put.TotalBytes]/
([VS.HSDPA.MeanChThroug
hput.Times]))

VS.HSDPA.MeanC byte HSDPA -


hThroughput.Total- Measuremen
Bytes t per cell

VS.HSDPA.UE.Mea numb HSDPA -


n.Cell er Measuremen
t per cell

VS.HSDPA.MACD. numb HSDPA -


Mean.Cell er Measuremen
t per cell

HSDPA VS.HSDPA.ChR.FA none HSDPA [VS.HSDPA.ChR.FACHtoHS


FACHto CHtoHSDSCH.Fail Measuremen DSCH.Att]-
HSDSC t per cell [VS.HSDPA.ChR.FACH-
H Fail toHSDSCH]

VS.HSDPA.ChR.FA times HSDPA -


CHtoHSDSCH.Att Measuremen
t per cell

HSDPA VS.HSDPA.ChR.HS none HSDPA [VS.HSDPA.ChR.HSDSCHto


HSDSC DSCHtoFACH.Fail Measuremen FACH.Att]-
HtoFAC t per cell [VS.HSDPA.ChR.HSDSCHto
H Fail FACH]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 751


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.HSDPA.ChR.HS times HSDPA -


DSCHtoFACH.Att Measuremen
t per cell

HSDPA VS.HSDPA.ChR.HS none HSDPA [VS.HSDPA.ChR.HSDSCHto


HSDSC DSCHtoDCH.Fail Measuremen DCH.Att]-
HtoDCH t per cell [VS.HSDPA.ChR.HSDSCHto
Fail DCH]

VS.HSDPA.ChR.HS times HSDPA -


DSCHtoDCH.Att Measuremen
t per cell

HSDPA VS.HSDPA.ChR.D none HSDPA [VS.HSDPA.ChR.DCHtoHSD


DCHtoH CHtoHSDSCH.Fail Measuremen SCH.Att]-
SDSCH t per cell [VS.HSDPA.ChR.DCHtoHSD
Fail SCH]

VS.HSDPA.ChR.D times HSDPA -


CHtoHSDSCH.Att Measuremen
t per cell

HSDPA VS.HSDPA.ServCel none HSDPA [VS.HSDPA.SHO.CellChg.At


ServCell lChg.SHO.Fail Measuremen tOut]-
Chg Fail t per cell [VS.HSDPA.SHO.CellChg.Su
ccOut]

VS.HSDPA.SHO.Ce times HSDPA -


llChg.AttOut Measuremen
t per cell

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.1.6 HSUPA KPI Report

Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 752


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

NE Type
RNC

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

HSUPA VS.HSUPA.RAB.Su % HSUPA [VS.HSUPA.RAB.SuccEs-


Access ccEstab.Rate Measuremen tab]/[VS.HSUPA.RAB.AttEs-
t per cell tab]*{100.00}

VS.HSUPA.RAB.Su numb HSUPA -


ccEstab er Measuremen
t per cell

VS.HSUPA.RAB.At numb HSUPA -


tEstab er Measuremen
t per cell

HSUPA VS.HSUPA.EDCH. % HSUPA [VS.HSUPA.EDCH.SHO.Suc


HO SHO.Succ.Ratio Measuremen c]/
t per cell [VS.HSUPA.EDCH.SHO.Att]
*{100.00}

VS.HSUPA.EDCH. times HSUPA -


SHO.Succ Measuremen
t per cell

VS.HSUPA.EDCH. times HSUPA -


SHO.Att Measuremen
t per cell

VS.HSUPA.SHO.Se % HSUPA [VS.HSUPA.SHO.ServCellCh


rvCellChg.Succ.Ra- Measuremen g.Succ]/
tio t per cell [VS.HSUPA.SHO.ServCellCh
g.Att]*{100.00}

VS.HSUPA.SHO.Se times HSUPA -


rvCellChg.Succ Measuremen
t per cell

VS.HSUPA.SHO.Se times HSUPA -


rvCellChg.Att Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 753


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.HSUPA.HHO.In % HSUPA [VS.HSUPA.HHO.InterFreq.


terFreq.NoChR.Succ Measuremen NoChR.Succ]/
.Ratio t per cell [VS.HSUPA.HHO.InterFreq.
NoChR.Att]*{100.00}

VS.HSUPA.HHO.In times HSUPA -


terFreq.NoChR.Succ Measuremen
t per cell

VS.HSUPA.HHO.In times HSUPA -


terFreq.NoChR.Att Measuremen
t per cell

HSUPA VS.HSUPA.RAB.A % HSUPA ([VS.HSUPA.RAB.Loss.Ab-


CDR bnormRel.Rate Measuremen norm])/
t per cell ([VS.HSUPA.RAB.Loss.Ab-
norm]+
[VS.HSUPA.RAB.Loss.Norm
]+
[VS.HSUPA.ChR.IntraCell.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.IntraFreq.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.InterFreq.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.EDCHtoFA
CH.Succ])*{100.00}

VS.HSUPA.RAB.A none HSUPA [VS.HSUPA.RAB.Loss.Ab-


bnormRel Measuremen norm]
t per cell

VS.HSUPA.RAB.Re none HSUPA [VS.HSUPA.RAB.Loss.Ab-


lease Measuremen norm]+
t per cell [VS.HSUPA.RAB.Loss.Norm
]+
[VS.HSUPA.ChR.IntraCell.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.IntraFreq.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.InterFreq.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.EDCHtoFA
CH.Succ]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 754


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.1.7 Traffic TopN Report

Report Type
Simple Report

NE Type
RNC

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Traffic VS.AMR.Ctrl.DL12. numb Measuremen -


2 er t of RB
Procedure
per cell

VS.RB.DLConvCS. numb Measuremen -


64 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


64 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


128 er t of RB
Procedure
per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 755


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RB.DLInterPS. numb Measuremen -


144 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


384 er t of RB
Procedure
per cell

VS.RB.DLBkgPS.64 numb Measuremen -


er t of RB
Procedure
per cell

VS.RB.DLBkgPS. numb Measuremen -


128 er t of RB
Procedure
per cell

VS.RB.DLBkgPS. numb Measuremen -


144 er t of RB
Procedure
per cell

VS.RB.DLBkgPS. numb Measuremen -


384 er t of RB
Procedure
per cell

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.2 Cluster Weekly Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 756


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

21.2.1 All Service KPI Report

Report Type
Simple Report

NE Type
RNC

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Traffic VS.AMR.Ctrl.DL12. numb Measuremen -


2 er t of RB
Procedure
per cell

VS.RB.DLConvCS. numb Measuremen -


64 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


64 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


128 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


144 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


384 er t of RB
Procedure
per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 757


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RB.DLBkgPS.64 numb Measuremen -


er t of RB
Procedure
per cell

VS.RB.DLBkgPS. numb Measuremen -


128 er t of RB
Procedure
per cell

VS.RB.DLBkgPS. numb Measuremen -


144 er t of RB
Procedure
per cell

VS.RB.DLBkgPS. numb Measuremen -


384 er t of RB
Procedure
per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 758


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Access VS.RRC.SuccConn % RRC ([RRC.SuccConnEstab.Og-


Estab.Service.Cell.R connection ConvCall]+
ate setup [RRC.SuccConnEstab.OrgStr-
measurement Call]+
per cell [RRC.SuccConnEstab.OrgItr-
Call]+
[RRC.SuccConnEstab.OrgBk
gCall]+
[RRC.SuccConnEstab.Org-
SubCall]+
[RRC.SuccConnEstab.TmCon
vCall]+
[RRC.SuccConnEstab.TmStr
Call]+
[RRC.SuccConnEstab.TmItr-
Call]+
[RRC.SuccConnEstab.TmBkg
Call]+
[RRC.SuccConnEstab.Emg-
Call]+
[RRC.SuccConnEstab.Un-
kown]+
[RRC.SuccConnEstab.OgHhP
rSig]+
[RRC.SuccConnEstab.OgLwP
rSig]+
[RRC.SuccConnEstab.CallRe-
Est]+
[RRC.SuccConnEstab.TmHhP
rSig]+
[RRC.SuccConnEstab.TmLw
PrSig])/
([RRC.AttConnEstab.Org-
ConvCall]+
[RRC.AttConnEstab.OrgStr-
Call]+
[RRC.AttConnEstab.OrgInter-
Call]+
[RRC.AttConnEstab.OrgBkg-
Call]+
[RRC.AttConnEstab.OgSub-
Call]+
[RRC.AttConnEstab.TmConv
Call]+
[RRC.AttConnEstab.TmStrCa
ll]+
[RRC.AttConnEstab.TmInter-

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 759


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Call]+
[RRC.AttConnEstab.TmBkgC
all]+
[RRC.AttConnEstab.Emg-
Call]+
[RRC.AttConnEstab.Un-
known]+
[RRC.AttConnEstab.OgHhPr-
Sig]+
[RRC.AttConnEstab.OgLwPr-
Sig]+
[RRC.AttConnEstab.CallRe-
Est]+
[RRC.AttConnEstab.TmHhPr
Sig]+
[RRC.AttConnEstab.TmLwPr
Sig])*{100.00}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 760


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RRC.SuccConn none RRC [RRC.SuccConnEstab.Og-


Estab.Service.Cell connection ConvCall]+
setup [RRC.SuccConnEstab.OrgStr-
measurement Call]+
per cell [RRC.SuccConnEstab.OrgItr-
Call]+
[RRC.SuccConnEstab.OrgBk
gCall]+
[RRC.SuccConnEstab.Org-
SubCall]+
[RRC.SuccConnEstab.TmCon
vCall]+
[RRC.SuccConnEstab.TmStr
Call]+
[RRC.SuccConnEstab.TmItr-
Call]+
[RRC.SuccConnEstab.TmBkg
Call]+
[RRC.SuccConnEstab.Emg-
Call]+
[RRC.SuccConnEstab.Un-
kown]+
[RRC.SuccConnEstab.OgHhP
rSig]+
[RRC.SuccConnEstab.OgLwP
rSig]+
[RRC.SuccConnEstab.CallRe-
Est]+
[RRC.SuccConnEstab.TmHhP
rSig]+
[RRC.SuccConnEstab.TmLw
PrSig]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 761


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RRC.AttConnEs none RRC [RRC.AttConnEstab.Org-


tab.Service.Cell connection ConvCall]+
setup [RRC.AttConnEstab.OrgStr-
measurement Call]+
per cell [RRC.AttConnEstab.OrgInter-
Call]+
[RRC.AttConnEstab.OrgBkg-
Call]+
[RRC.AttConnEstab.OgSub-
Call]+
[RRC.AttConnEstab.TmConv
Call]+
[RRC.AttConnEstab.TmStrCa
ll]+
[RRC.AttConnEstab.TmInter-
Call]+
[RRC.AttConnEstab.TmBkgC
all]+
[RRC.AttConnEstab.Emg-
Call]+
[RRC.AttConnEstab.Un-
known]+
[RRC.AttConnEstab.OgHhPr-
Sig]+
[RRC.AttConnEstab.OgLwPr-
Sig]+
[RRC.AttConnEstab.CallRe-
Est]+
[RRC.AttConnEstab.TmHhPr
Sig]+
[RRC.AttConnEstab.TmLwPr
Sig]

VS.RRC.SuccConn % RRC ([RRC.SuccConnEstab.IRAT-


Estab.Other.Cell.Rat connection CelRes]+
e setup [RRC.SuccConnEstab.IRATC
measurement CO]+
per cell [RRC.SuccConnEstab.Reg]+
[RRC.SuccConnEstab.De-
tach])/
([RRC.AttConnEstab.IRAT-
CelRes]+
[RRC.AttConnEstab.IRATC-
CO]+
[RRC.AttConnEstab.Reg]+
[RRC.AttConnEstab.Detach])
*{100.00}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 762


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RRC.SuccConn none RRC [RRC.SuccConnEstab.IRAT-


Estab.Other.Cell connection CelRes]+
setup [RRC.SuccConnEstab.IRATC
measurement CO]+
per cell [RRC.SuccConnEstab.Reg]+
[RRC.SuccConnEstab.Detach]

VS.RRC.AttConnEs none RRC [RRC.AttConnEstab.IRAT-


tab.Other.Cell connection CelRes]+
setup [RRC.AttConnEstab.IRATC-
measurement CO]+
per cell [RRC.AttConnEstab.Reg]+
[RRC.AttConnEstab.Detach]

VS.RAB.SuccEstab % Measuremen [VS.RAB.SuccEstab.AMR]/


CS.AMR.Cell.Rate t of CS RAB [VS.RAB.AttEstab.AMR]*
assignment {100.00}
setup per cell

VS.RAB.SuccEstab. numb Measuremen -


AMR er t of CS RAB
assignment
setup per cell

VS.RAB.AttEstab.A numb Measuremen -


MR er t of CS RAB
assignment
setup per cell

VS.RAB.SuccEstab % Measuremen [VS.RAB.SuccEstCS.Conv.


CS.Conv. t of CS RAB 64]/[VS.RAB.AttEstCS.Conv.
64.Cell.Rate assignment 64]*{100.00}
setup per cell

VS.RAB.SuccEstCS numb Measuremen -


.Conv.64 er t of CS RAB
assignment
setup per cell

VS.RAB.AttEstCS. numb Measuremen -


Conv.64 er t of CS RAB
assignment
setup per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 763


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.SuccEstab % Measuremen ([VS.RAB.SuccEstabPS.Conv


PS.Cell.Rate t of PS RAB ]+[VS.RAB.SuccEstabPS.Str]
assignment +[VS.RAB.SuccEstabPS.In-
setup per cell ter]+
[VS.RAB.SuccEstabPS.Bkg])/
([VS.RAB.AttEstabPS.Conv]
+[VS.RAB.AttEstabPS.Str]+
[VS.RAB.AttEstabPS.Inter]+
[VS.RAB.AttEstabPS.Bkg])*
{100.00}

VS.RAB.SuccEstPS. none Measuremen [VS.RAB.SuccEstabPS.Conv]


Cell t of PS RAB +[VS.RAB.SuccEstabPS.Str]+
assignment [VS.RAB.SuccEstabPS.Inter]
setup per cell +[VS.RAB.SuccEstabPS.Bkg]

VS.RAB.AttEstabPS numb Measuremen [VS.RAB.AttEstabPS.Conv]+


.Cell er t of PS RAB [VS.RAB.AttEstabPS.Str]+
assignment [VS.RAB.AttEstabPS.Inter]+
setup per cell [VS.RAB.AttEstabPS.Bkg]

HO VS.SHO.Factor.RL. none Soft (([VS.SHO.AS.1RL]+


Cell Handover [VS.SHO.AS.2RL]+
Measuremen [VS.SHO.AS.3RL]+
t per cell [VS.SHO.AS.4RL]+
[VS.SHO.AS.5RL]+
[VS.SHO.AS.6RL])/
([VS.SHO.AS.1RL]+
[VS.SHO.AS.2RL]/{2}+
[VS.SHO.AS.3RL]/{3}+
[VS.SHO.AS.4RL]/{4}+
[VS.SHO.AS.5RL]/{5}+
[VS.SHO.AS.6RL]/{6}))-{1}

VS.SHO.Success.Ce % Soft ([SHO.SuccRLAddUESide]+


ll.Rate Handover [SHO.SuccRLDelUESide])/
Measuremen ([SHO.AttRLAddUESide]+
t per cell [SHO.AttRLDelUESide])*
{100.00}

VS.SHO.SuccUESid none Soft [SHO.SuccRLAddUESide]+


e.Cell Handover [SHO.SuccRLDelUESide]
Measuremen
t per cell

VS.SHO.AttUESide. none Soft [SHO.AttRLAddUESide]+


Cell Handover [SHO.AttRLDelUESide]
Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 764


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.HHO.InterFreq. % Hard [VS.HHO.InterFreq.SuccOut]/


Out.Cell.Rate Handover [VS.HHO.InterFreq.AttOut]*
Measuremen {100.00}
t per cell

VS.HHO.InterFreq.S times Hard -


uccOut Handover
Measuremen
t per cell

VS.HHO.InterFreq. times Hard -


AttOut Handover
Measuremen
t per cell

VS.IRATHO.SuccO % InterRAT [IRATHO.SuccOutCS]/


utCS.Cell.Rate Handover [IRATHO.AttOutCS]*
Measuremen {100.00}
t per cell

IRATHO.SuccOutC times InterRAT -


S Handover
Measuremen
t per cell

IRATHO.AttOutCS times InterRAT -


Handover
Measuremen
t per cell

VS.IRATHO.SuccO % InterRAT [IRATHO.SuccOutPSU-


utPSUNTRAN.Cell. Handover TRAN]/[IRATHO.AttOut-
Rate Measuremen PSUTRAN]*{100.00}
t per cell

IRATHO.SuccOut- times InterRAT -


PSUTRAN Handover
Measuremen
t per cell

IRATHO.AttOut- times InterRAT -


PSUTRAN Handover
Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 765


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

CDR VS.CS.AMR.Call.D % Measuremen [VS.RAB.Loss.CS.AMR]/


rop.Cell.Rate t of RAB ([VS.RAB.Loss.CS.AMR]+
release [VS.RAB.Loss.CS.Norm.AM
triggered by R])*{100.00}
UTRAN per
cell

VS.CS.AMR.Call.D none Measuremen [VS.RAB.Loss.CS.AMR]


rop.Cell t of RAB
release
triggered by
UTRAN per
cell

VS.CS.AMR.Re- none Measuremen [VS.RAB.Loss.CS.AMR]+


lease t of RAB [VS.RAB.Loss.CS.Norm.AM
release R]
triggered by
UTRAN per
cell

VS.CS.VP.Call.Dro % Measuremen [VS.RAB.Loss.CS.Conv64K]/


p.Cell.Rate t of RAB ([VS.RAB.Loss.CS.Conv64K]
release +[VS.Norm.Rel.CS.Conv.RB.
triggered by 64])*{100.00}
UTRAN per
cell

VS.CS.VP.Call.Dro none Measuremen [VS.RAB.Loss.CS.Conv64K]


p.Cell t of RAB
release
triggered by
UTRAN per
cell

VS.CS.VP.Release none Measuremen [VS.RAB.Loss.CS.Conv64K]


t of RAB +[VS.Norm.Rel.CS.Conv.RB.
release 64]
triggered by
UTRAN per
cell

VS.PS.Call.Drop.Ce % Measuremen ([VS.RAB.Loss.PS.RF]+


ll.Rate t of RAB [VS.RAB.Loss.PS.Abnorm])/
release ([VS.RAB.Loss.PS.RF]+
triggered by [VS.RAB.Loss.PS.Abnorm]+
UTRAN per [VS.RAB.Loss.PS.Norm])*
cell {100.00}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 766


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.PS.Call.Drop.Ce numb Measuremen [VS.RAB.Loss.PS.RF]+


ll er t of RAB [VS.RAB.Loss.PS.Abnorm]
release
triggered by
UTRAN per
cell

VS.RAB.Release.PS none Measuremen [VS.RAB.Loss.PS.RF]+


.Cell t of RAB [VS.RAB.Loss.PS.Abnorm]+
release [VS.RAB.Loss.PS.Norm]
triggered by
UTRAN per
cell

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.2.2 HSDPA KPI Report

Report Type
Simple Report

NE Type
RNC

Object Type
RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 767


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

HSDPA VS.HSDPA.MeanC none HSDPA [VS.HSDPA.MeanChThrough


Traffic hThroughput.Total- Measuremen put.TotalBytes]/({1024}*
MBytes t per cell {1024})

VS.HSDPA.UE.Mea numb HSDPA -


n.Cell er Measuremen
t per cell

VS.HSDPA.MeanC none HSDPA ([VS.HSDPA.MeanChThroug


hThroughput.To- Measuremen hput.TotalBytes]*{8.0}/
talMBps t per cell ({1024.0}*{1024.0}))/({GP}*
{60})

HSDPA VS.HSDPA.RAB.Su % HSDPA [VS.HSDPA.RAB.SuccEs-


Access ccEstab.Rate Measuremen tab]/[VS.HSDPA.RAB.AttEs-
t per cell tab]*{100.00}

VS.HSDPA.RAB.Su times HSDPA -


ccEstab Measuremen
t per cell

VS.HSDPA.RAB.At times HSDPA -


tEstab Measuremen
t per cell

HSDPA VS.HSDPA.ServCel % HSDPA [VS.HSDPA.SHO.CellChg.Su


HO lChg.Succ.Rate Measuremen ccOut]/
t per cell [VS.HSDPA.SHO.CellChg.At
tOut]*{100.00}

VS.HSDPA.SHO.Ce times HSDPA -


llChg.SuccOut Measuremen
t per cell

VS.HSDPA.SHO.Ce times HSDPA -


llChg.AttOut Measuremen
t per cell

VS.HSDPA.HHO.In % HSDPA [VS.HSDPA.HHO.SuccOu-


traFreq.NoChR.Succ Measuremen tIntraFreq]/
.Rate t per cell [VS.HSDPA.HHO.AttOutIn-
traFreq]*{100.00}

VS.HSDPA.HHO.S times HSDPA -


uccOutIntraFreq Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 768


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.HSDPA.HHO.At times HSDPA -


tOutIntraFreq Measuremen
t per cell

VS.HSDPA.HHO.In % HSDPA [VS.HSDPA.HHO.SuccOu-


terFreq.NoChR.Succ Measuremen tInterFreq]/
.Rate t per cell [VS.HSDPA.HHO.AttOutIn-
terFreq]*{100.00}

VS.HSDPA.HHO.S times HSDPA -


uccOutInterFreq Measuremen
t per cell

VS.HSDPA.HHO.At times HSDPA -


tOutInterFreq Measuremen
t per cell

VS.HSDPA.ChR.HS % HSDPA [VS.HSDPA.ChR.HSDSCHto


DSCHtoDCH.Succ. Measuremen DCH]/
Rate t per cell [VS.HSDPA.ChR.HSDSCHto
DCH.Att]*{100.00}

VS.HSDPA.ChR.HS times HSDPA -


DSCHtoDCH Measuremen
t per cell

VS.HSDPA.ChR.HS times HSDPA -


DSCHtoDCH.Att Measuremen
t per cell

VS.HSDPA.ChR.D % HSDPA [VS.HSDPA.ChR.DCHtoHSD


CHtoHSDSCH.Succ Measuremen SCH]/
.Rate t per cell [VS.HSDPA.ChR.DCHtoHSD
SCH.Att]*{100.00}

VS.HSDPA.ChR.D times HSDPA -


CHtoHSDSCH Measuremen
t per cell

VS.HSDPA.ChR.D times HSDPA -


CHtoHSDSCH.Att Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 769


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

HSDPA VS.HSDPA.RAB.A % HSDPA ([VS.HSDPA.RAB.Loss.Abn


CDR bnormRel.Rate Measuremen orm.NonRF]+
t per cell [VS.HSDPA.RAB.Loss.RF])/
([VS.HSDPA.RAB.Loss.In-
Activity]+
[VS.HSDPA.RAB.Loss.Abno
rm.NonRF]+
[VS.HSDPA.RAB.Loss.RF]+
[VS.HSDPA.RAB.Loss.Norm
]+
[VS.HSDPA.ChR.HSDSCHto
DCH]+
[VS.HSDPA.ChR.HSDSCHto
FACH]+
[VS.HSDPA.HHO.H2D.Suc-
cOutIntraFreq]+
[VS.HSDPA.HHO.H2D.Suc-
cOutInterFreq])*{100.00}

VS.HSDPA.RAB.A none HSDPA [VS.HSDPA.RAB.Loss.Abno


bnormRel Measuremen rm.NonRF]+
t per cell [VS.HSDPA.RAB.Loss.RF]

VS.HSDPA.RAB.Re none HSDPA [VS.HSDPA.RAB.Loss.InAc-


l Measuremen tivity]+
t per cell [VS.HSDPA.RAB.Loss.Abno
rm.NonRF]+
[VS.HSDPA.RAB.Loss.RF]+
[VS.HSDPA.RAB.Loss.Norm
]+
[VS.HSDPA.ChR.HSDSCHto
DCH]+
[VS.HSDPA.ChR.HSDSCHto
FACH]+
[VS.HSDPA.HHO.H2D.Suc-
cOutIntraFreq]+
[VS.HSDPA.HHO.H2D.Suc-
cOutInterFreq]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 770


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.2.3 HSUPA KPI Report

Report Type
Simple Report

NE Type
RNC

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

HSUPA VS.HSUPA.RAB.Su % HSUPA [VS.HSUPA.RAB.SuccEs-


Access ccEstab.Rate Measuremen tab]/[VS.HSUPA.RAB.AttEs-
t per cell tab]*{100.00}

VS.HSUPA.RAB.Su numb HSUPA -


ccEstab er Measuremen
t per cell

VS.HSUPA.RAB.At numb HSUPA -


tEstab er Measuremen
t per cell

HSUPA VS.HSUPA.EDCH. % HSUPA [VS.HSUPA.EDCH.SHO.Suc


HO SHO.Succ.Ratio Measuremen c]/
t per cell [VS.HSUPA.EDCH.SHO.Att]
*{100.00}

VS.HSUPA.EDCH. times HSUPA -


SHO.Succ Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 771


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.HSUPA.EDCH. times HSUPA -


SHO.Att Measuremen
t per cell

VS.HSUPA.SHO.Se % HSUPA [VS.HSUPA.SHO.ServCellCh


rvCellChg.Succ.Ra- Measuremen g.Succ]/
tio t per cell [VS.HSUPA.SHO.ServCellCh
g.Att]*{100.00}

VS.HSUPA.SHO.Se times HSUPA -


rvCellChg.Succ Measuremen
t per cell

VS.HSUPA.SHO.Se times HSUPA -


rvCellChg.Att Measuremen
t per cell

VS.HSUPA.HHO.In % HSUPA [VS.HSUPA.HHO.InterFreq.


terFreq.NoChR.Succ Measuremen NoChR.Succ]/
.Ratio t per cell [VS.HSUPA.HHO.InterFreq.
NoChR.Att]*{100.00}

VS.HSUPA.HHO.In times HSUPA -


terFreq.NoChR.Succ Measuremen
t per cell

VS.HSUPA.HHO.In times HSUPA -


terFreq.NoChR.Att Measuremen
t per cell

HSUPA VS.HSUPA.RAB.A % HSUPA ([VS.HSUPA.RAB.Loss.Ab-


CDR bnormRel.Rate Measuremen norm])/
t per cell ([VS.HSUPA.RAB.Loss.Ab-
norm]+
[VS.HSUPA.RAB.Loss.Norm
]+
[VS.HSUPA.ChR.IntraCell.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.IntraFreq.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.InterFreq.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.EDCHtoFA
CH.Succ])*{100.00}

VS.HSUPA.RAB.A none HSUPA [VS.HSUPA.RAB.Loss.Ab-


bnormRel Measuremen norm]
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 772


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.HSUPA.RAB.Re none HSUPA [VS.HSUPA.RAB.Loss.Ab-


lease Measuremen norm]+
t per cell [VS.HSUPA.RAB.Loss.Norm
]+
[VS.HSUPA.ChR.IntraCell.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.IntraFreq.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.InterFreq.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.EDCHtoFA
CH.Succ]

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.3 Monitoring Report

21.3.1 Access TopN Report

Report Type
Simple Report

NE Type
RNC

Object Type
UCell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 773


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

RRC VS.RRC.FailConnE times RRC [VS.RRC.AttConnEstab.Cell]-


Failed stab.Cell connection [RRC.SuccConnEstab.sum]
setup
measurement
per cell

VS.RRC.AttConnEs times RRC -


tab.Cell connection
setup
measurement
per cell

VS.RRC.Rej.RL.Fai times RRC -


l connection
reject
measurement
per cell

VS.RRC.Rej.TNL.F times RRC -


ail connection
reject
measurement
per cell

RRC.FailConnEstab. times RRC -


Cong connection
reject
measurement
per cell

VS.RRC.Rej.Power. times RRC -


Cong connection
reject
measurement
per cell

VS.RRC.Rej.UL.CE times RRC -


.Cong connection
reject
measurement
per cell

VS.RRC.Rej.DL.CE times RRC -


.Cong connection
reject
measurement
per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 774


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RRC.Rej.Code.C times RRC -


ong connection
reject
measurement
per cell

VS.RRC.Rej.Other. times RRC [RRC.FailConnEstab.Cong]-


Cong connection [VS.RRC.Rej.Power.Cong]-
reject [VS.RRC.Rej.Code.Cong]-
measurement [VS.RRC.Rej.UL.CE.Cong]-
per cell [VS.RRC.Rej.DL.CE.Cong]

RRC.FailConnEstab. times RRC -


NoReply connection
reject
measurement
per cell

CS RAB VS.RAB.FailEstabC numb Measuremen [VS.RAB.AttEstabCS.Conv]+


Failed S.Cell er t of CS RAB [VS.RAB.AttEstabCS.Str]-
assignment [VS.RAB.SuccEstabCS.Conv]
setup per cell -[VS.RAB.SuccEstabCS.Str]

VS.RAB.AttEstabC numb Measuremen [VS.RAB.AttEstabCS.Conv]+


S.Cell er t of CS RAB [VS.RAB.AttEstabCS.Str]
assignment
setup per cell

VS.RAB.FailEstabC numb Measuremen -


S.TNL er t of CS RAB
assignment
failure per
cell

VS.RAB.FailEstabC numb Measuremen -


S.RNL er t of CS RAB
assignment
failure per
cell

VS.RAB.FailEstCS. numb Measuremen -


Unsp er t of CS RAB
assignment
failure per
cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 775


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.FailEstCS. numb Measuremen -


Relo er t of CS RAB
assignment
failure per
cell

VS.RAB.FailEstCS. numb Measuremen -


RIPFail er t of CS RAB
assignment
failure per
cell

VS.RAB.FailEstCs. numb Measuremen -


Power.Cong er t of CS RAB
assignment
failure per
cell

VS.RAB.FailEstCs. numb Measuremen -


ULCE.Cong er t of CS RAB
assignment
failure per
cell

VS.RAB.FailEstCs. numb Measuremen -


DLCE.Cong er t of CS RAB
assignment
failure per
cell

VS.RAB.FailEstCs. numb Measuremen -


Code.Cong er t of CS RAB
assignment
failure per
cell

VS.RAB.FailEstabC numb Measuremen [VS.RAB.FailEstabCS.RNL]-


S.RNL.Other er t of CS RAB [VS.RAB.FailEstCS.Relo]-
assignment [VS.RAB.FailEstCS.RIPFail]-
failure per [VS.RAB.FailEstabCS.Cong]
cell

VS.RAB.FailEstabC none Measuremen ([VS.RAB.AttEstabCS.Conv]


S.other.CELL t of CS RAB +[VS.RAB.AttEstabCS.Str]-
assignment [VS.RAB.SuccEstabCS.Conv]
setup per cell -[VS.RAB.SuccEstabCS.Str])-
[VS.RAB.FailEstabCS.RNL]-
[VS.RAB.FailEstabCS.TNL]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 776


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

PS RAB VS.RAB.FailEstabP numb Measuremen ([VS.RAB.AttEstabPS.Conv]


Failed S.Cell er t of PS RAB +[VS.RAB.AttEstabPS.Str]+
assignment [VS.RAB.AttEstabPS.Inter]+
setup per cell [VS.RAB.AttEstabPS.Bkg])-
([VS.RAB.SuccEstabPS.Conv
]+[VS.RAB.SuccEstabPS.Str]
+[VS.RAB.SuccEstabPS.In-
ter]+
[VS.RAB.SuccEstabPS.Bkg])

VS.RAB.AttEstabPS numb Measuremen [VS.RAB.AttEstabPS.Conv]+


.Cell er t of PS RAB [VS.RAB.AttEstabPS.Str]+
assignment [VS.RAB.AttEstabPS.Inter]+
setup per cell [VS.RAB.AttEstabPS.Bkg]

VS.RAB.AttEstabPS numb Measuremen -


.Conv er t of PS RAB
assignment
setup per cell

VS.RAB.FailEstPS. numb Measuremen -


RNL er t of PS RAB
assignment
failure per
cell

VS.RAB.FailEstPS. numb Measuremen -


Unsp er t of PS RAB
assignment
failure per
cell

VS.RAB.FailEstPS. numb Measuremen -


RIPFail er t of PS RAB
assignment
failure per
cell

VS.RAB.FailEstPS. numb Measuremen -


Par er t of PS RAB
assignment
failure per
cell

VS.RAB.FailEstPS. numb Measuremen -


Relo er t of PS RAB
assignment
failure per
cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 777


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.FailEstPs.P numb Measuremen -


ower.Cong er t of PS RAB
assignment
failure per
cell

VS.RAB.FailEstPs. numb Measuremen -


Code.Cong er t of PS RAB
assignment
failure per
cell

VS.RAB.FailEstPs. numb Measuremen -


ULCE.Cong er t of PS RAB
assignment
failure per
cell

VS.RAB.FailEstPs. numb Measuremen -


DLCE.Cong er t of PS RAB
assignment
failure per
cell

VS.RAB.FailEstab.P numb Measuremen -


S.ULIUBBand.Cong er t of PS RAB
assignment
failure per
cell

VS.RAB.FailEstab.P numb Measuremen -


S.DLIUBBand.Cong er t of PS RAB
assignment
failure per
cell

VS.RAB.FlEstPS.R numb Measuremen [VS.RAB.FailEstPS.RNL]-


NL.Other er t of PS RAB [VS.RAB.FailEstPS.RIPFail]-
assignment [VS.RAB.FailEstPS.Par]-
failure per [VS.RAB.FailEstPS.Relo]-
cell [VS.RAB.FailEstPS.Unsp]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 778


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.FailEstabP numb Measuremen (([VS.RAB.AttEstabPS.Conv]


S.Other.Cell er t of PS RAB +[VS.RAB.AttEstabPS.Str]+
assignment [VS.RAB.AttEstabPS.Inter]+
setup per cell [VS.RAB.AttEstabPS.Bkg])-
([VS.RAB.SuccEstabPS.Conv
]+[VS.RAB.SuccEstabPS.Str]
+[VS.RAB.SuccEstabPS.In-
ter]+
[VS.RAB.SuccEstabPS.Bkg]))
-[VS.RAB.FailEstPS.TNL]-
[VS.RAB.FailEstPS.RNL]

HSDPA VS.HSDPA.RAB.Fa none HSDPA [VS.HSDPA.RAB.AttEstab]-


RAB ilEstab Measuremen [VS.HSDPA.RAB.SuccEstab]
Failed t per cell

HSUPA VS.HSUPA.RAB.Fa none HSUPA [VS.HSUPA.RAB.AttEstab]-


RAB ilEstab Measuremen [VS.HSUPA.RAB.SuccEstab]
Failed t per cell

HSDPA VS.HSDPA.ChR.HS none HSDPA [VS.HSDPA.ChR.HSDSCHto


ChR DSCHtoDCH.Fail Measuremen DCH.Att]-
HSDSC t per cell [VS.HSDPA.ChR.HSDSCHto
HtoDCH DCH]
Fail
VS.HSDPA.ChR.HS times HSDPA -
DSCHtoDCH.Att Measuremen
t per cell

HSDPA VS.HSDPA.ChR.D none HSDPA [VS.HSDPA.ChR.DCHtoHSD


ChR CHtoHSDSCH.Fail Measuremen SCH.Att]-
DCHtoH t per cell [VS.HSDPA.ChR.DCHtoHSD
SDSCH SCH]
Fail
VS.HSDPA.ChR.D times HSDPA -
CHtoHSDSCH.Att Measuremen
t per cell

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 779


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

21.3.2 CDR TopN Report

Report Type
Simple Report

NE Type
RNC

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

CS Call VS.CS.Call.Drop.Ce numb Measuremen [VS.RAB.Loss.CS.RF]+


Drop ll er t of RAB [VS.RAB.Loss.CS.Abnorm]
release
triggered by
UTRAN per
cell

VS.RAB.SuccEstab none Measuremen [VS.RAB.SuccEstabCS.Conv]


CS.Cell t of CS RAB +[VS.RAB.SuccEstabCS.Str]
assignment
setup per cell

VS.RAB.RelReqCS. numb Measuremen -


OM er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.RelReqCS. numb Measuremen -


RABPreempt er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.RelReqCS. numb Measuremen -


UTRANgen er t of RAB
release
triggered by
UTRAN per
cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 780


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.Loss.CS.R numb Measuremen -


F er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.CS.R numb Measuremen -


F.RLCRst er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.CS.R numb Measuremen -


F.ULSync er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.CS.R numb Measuremen -


F.UuNoReply er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.CS.R numb Measuremen -


F.Oth er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.CS.A numb Measuremen -


al2Loss er t of RAB
release
triggered by
UTRAN per
cell

VS.Call.Drop.CS.Ot numb Measuremen [VS.RAB.Loss.CS.Abnorm]-


her er t of RAB [VS.RAB.RelReqCS.OM]-
release [VS.RAB.RelReqCS.UTRAN
triggered by gen]-
UTRAN per [VS.RAB.RelReqCS.RAB-
cell Preempt]-
[VS.RAB.Loss.CS.Aal2Loss]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 781


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

PS Call VS.PS.Call.Drop.Ce numb Measuremen [VS.RAB.Loss.PS.RF]+


Drop ll er t of RAB [VS.RAB.Loss.PS.Abnorm]
release
triggered by
UTRAN per
cell

VS.RAB.SuccEstPS. none Measuremen [VS.RAB.SuccEstabPS.Conv]


Cell t of PS RAB +[VS.RAB.SuccEstabPS.Str]+
assignment [VS.RAB.SuccEstabPS.Inter]
setup per cell +[VS.RAB.SuccEstabPS.Bkg]

VS.RAB.RelReqPS. numb Measuremen -


OM er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.RelReqPS. numb Measuremen -


RABPreempt er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.PS.R numb Measuremen -


F er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.PS.R numb Measuremen -


F.RLCRst er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.PS.R numb Measuremen -


F.ULSync er t of RAB
release
triggered by
UTRAN per
cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 782


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.Loss.PS.R numb Measuremen -


F.UuNoReply er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.PS.R numb Measuremen -


F.Oth er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.PS.G numb Measuremen -


TPULoss er t of RAB
release
triggered by
UTRAN per
cell

VS.Call.Drop.PS.Ot numb Measuremen [VS.RAB.Loss.PS.Abnorm]-


her er t of RAB [VS.RAB.RelReqPS.OM]-
release [VS.RAB.RelReqPS.RAB-
triggered by Preempt]-
UTRAN per [VS.RAB.Loss.PS.GTPU-
cell Loss]

HSDPA VS.HSDPA.RAB.A none HSDPA [VS.HSDPA.RAB.Loss.Abno


Call bnormRel Measuremen rm.NonRF]+
Drop t per cell [VS.HSDPA.RAB.Loss.RF]

VS.HSDPA.RAB.Re none HSDPA [VS.HSDPA.RAB.Loss.InAc-


lease Measuremen tivity]+
t per cell [VS.HSDPA.RAB.Loss.Abno
rm.NonRF]+
[VS.HSDPA.RAB.Loss.RF]+
[VS.HSDPA.RAB.Loss.Norm
]+
[VS.HSDPA.ChR.HSDSCHto
DCH]+
[VS.HSDPA.ChR.HSDSCHto
FACH]+
[VS.HSDPA.HHO.H2D.Suc-
cOutIntraFreq]+
[VS.HSDPA.HHO.H2D.Suc-
cOutInterFreq]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 783


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

HSUPA VS.HSUPA.RAB.A none HSUPA [VS.HSUPA.RAB.Loss.Ab-


Call bnormRel Measuremen norm]
Drop t per cell

VS.HSUPA.RAB.Re none HSUPA [VS.HSUPA.RAB.Loss.Ab-


lease Measuremen norm]+
t per cell [VS.HSUPA.RAB.Loss.Norm
]+
[VS.HSUPA.ChR.IntraCell.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.IntraFreq.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.InterFreq.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.EDCHtoFA
CH.Succ]

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.3.3 HO TopN Report

Report Type
Simple Report

NE Type
RNC

Object Type
UCell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 784


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

SHO VS.SHO.Fail.Cell none Soft [SHO.AttRLAddUESide]+


Failed Handover [SHO.AttRLDelUESide]-
Measuremen [SHO.SuccRLAddUESide]-
t per cell [SHO.SuccRLDelUESide]

VS.SHO.AttUESide. none Soft [SHO.AttRLAddUESide]+


Cell Handover [SHO.AttRLDelUESide]
Measuremen
t per cell

SHO.FailRLAddUE times Soft -


Side.CfgUnsup Handover
Measuremen
t per cell

SHO.FailRLAddUE times Soft -


Side.Isr Handover
Measuremen
t per cell

SHO.FailRLAddUE times Soft -


Side.InvCfg Handover
Measuremen
t per cell

SHO.FailRLAddUE times Soft -


Side.NoReply Handover
Measuremen
t per cell

VS.SHO.Fail.Other. none Soft ([SHO.AttRLAddUESide]+


Cell Handover [SHO.AttRLDelUESide]-
Measuremen [SHO.SuccRLAddUESide]-
t per cell [SHO.SuccRLDelUESide])-
[SHO.FailRLAddUESide.Cfg
Unsup]-
[SHO.FailRLAddUESide.Isr]-
[SHO.FailRLAddUESide.Inv
Cfg]-
[SHO.FailRLAddUESide.No
Reply]

InterFRe VS.HHO.InterFreq.F none Hard [VS.HHO.InterFreq.AttOut]-


quest ailOut Handover [VS.HHO.InterFreq.SuccOut]
HHO Measuremen
Failed t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 785


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.HHO.InterFreq. times Hard -


AttOut Handover
Measuremen
t per cell

VS.HHO.InterFreqO times Hard -


ut.CfgUnsupp Handover
Measuremen
t per cell

VS.HHO.InterFreqO times Hard -


ut.PyhChFail Handover
Measuremen
t per cell

VS.HHO.InterFreqO times Hard -


ut.FailUSR Handover
Measuremen
t per cell

VS.HHO.InterFreqO times Hard -


ut.CellUpdt Handover
Measuremen
t per cell

VS.HHO.InterFreqO times Hard -


ut.CfgInvalid Handover
Measuremen
t per cell

VS.HHO.InterFreqO times Hard -


ut.NoReply Handover
Measuremen
t per cell

VS.HHO.InterFreqO times Hard -


ut.DLCodeRej Handover
Measuremen
t per cell

VS.HHO.InterFreqO times Hard -


ut.ULAdmsnDeny Handover
Measuremen
t per cell

VS.HHO.InterFreqO times Hard -


ut.DLAdmsnDeny Handover
Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 786


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.HHO.InterFreq.F none Hard ([VS.HHO.InterFreq.AttOut]-


ailOther Handover [VS.HHO.InterFreq.Suc-
Measuremen cOut])-
t per cell [VS.HHO.InterFreqOut.CfgU
nsupp]-
[VS.HHO.InterFreqOut.PyhC
hFail]-
[VS.HHO.InterFreqOut.Fail-
USR]-
[VS.HHO.InterFreqOut.Cel-
lUpdt]-
[VS.HHO.InterFreqOut.CfgIn
valid]-
[VS.HHO.InterFreqOut.NoRe
ply]

CS VS.IRATHO.Fail- none InterRAT [IRATHO.AttOutCS]-


InterRA OutCS Handover [IRATHO.SuccOutCS]
T HHO Measuremen
Failed t per cell

IRATHO.AttOutCS times InterRAT -


Handover
Measuremen
t per cell

IRATHO.FailOutCS times InterRAT -


.CfgUnsupp Handover
Measuremen
t per cell

IRATHO.FailOutCS times InterRAT -


.PhyChFail Handover
Measuremen
t per cell

VS.IRATHO.FailOu none InterRAT ([IRATHO.AttOutCS]-


tCS.Other Handover [IRATHO.SuccOutCS])-
Measuremen [IRATHO.FailOutCS.CfgUn-
t per cell supp]-
[IRATHO.FailOutCS.PhyCh-
Fail]

PS VS.IRATHO.FailOu none InterRAT [IRATHO.AttOutPSUTRAN]-


InterRA tPSUTRAN.Cell Handover [IRATHO.SuccOutPSU-
T HHO Measuremen TRAN]
Failed t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 787


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

IRATHO.AttOut- times InterRAT -


PSUTRAN Handover
Measuremen
t per cell

IRATHO.FailOutPS times InterRAT -


UTRAN.CfgUnsupp Handover
Measuremen
t per cell

IRATHO.FailOutPS times InterRAT -


UTRAN.PhyChFail Handover
Measuremen
t per cell

VS.IRATHO.FailOu none InterRAT [IRATHO.AttOutPSUTRAN]-


tPSUTRAN.Other Handover [IRATHO.SuccOutPSU-
Measuremen TRAN]-
t per cell [IRATHO.FailOutPSUTRAN.
CfgUnsupp]-
[IRATHO.FailOutPSUTRAN.
PhyChFail]

HSDPA VS.HSDPA.ServCel none HSDPA [VS.HSDPA.SHO.CellChg.At


ServCell lChg.SHO.Fail Measuremen tOut]-
Chg SHO t per cell [VS.HSDPA.SHO.CellChg.Su
Fail ccOut]

VS.HSDPA.SHO.Ce times HSDPA -


llChg.AttOut Measuremen
t per cell

HSDPA VS.HSDPA.ServCel none HSDPA [VS.HSDPA.HHO.AttOutIn-


HHO lChg.HHO.IntraFreq Measuremen traFreq]-
IntraFRe .NoChR.Fail t per cell [VS.HSDPA.HHO.SuccOu-
quest tIntraFreq]
NoChR
Fail VS.HSDPA.HHO.At times HSDPA -
tOutIntraFreq Measuremen
t per cell

HSDPA VS.HSDPA.ServCel none HSDPA [VS.HSDPA.HHO.AttOutIn-


HHO lChg.HHO.InterFreq Measuremen terFreq]-
InterFRe .NoChR.Fail t per cell [VS.HSDPA.HHO.SuccOu-
quest tInterFreq]
NoChR
Fail VS.HSDPA.HHO.At times HSDPA -
tOutInterFreq Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 788


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

HSUPA VS.HSUPA.EDCH. none HSUPA [VS.HSUPA.EDCH.SHO.Att]


EDCH SHO.Fail Measuremen -
SHO Fail t per cell [VS.HSUPA.EDCH.SHO.Suc
c]

VS.HSUPA.EDCH. times HSUPA -


SHO.Att Measuremen
t per cell

HSUPA VS.HSUPA.SHO.Se none HSUPA [VS.HSUPA.SHO.ServCellCh


SHO rvCellChg.Fail Measuremen g.Att]-
ServCell t per cell [VS.HSUPA.SHO.ServCellCh
Chg Fail g.Succ]

VS.HSUPA.SHO.Se times HSUPA -


rvCellChg.Att Measuremen
t per cell

HSUPA VS.HSUPA.HHO.In none HSUPA [VS.HSUPA.HHO.InterFreq.


HHO terFreq.NoChR.Fail Measuremen NoChR.Att]-
InterFRe t per cell [VS.HSUPA.HHO.InterFreq.
quest NoChR.Succ]
NoChR
Fail VS.HSUPA.HHO.In times HSUPA -
terFreq.NoChR.Att Measuremen
t per cell

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.3.4 RNC KPI Report

Report Type
Simple Report

NE Type
RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 789


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

KPI1 VS.AMR.RB.DL. numb Measuremen -


12.2 er t related to
AMR service

VS.RB.DLConvCS. numb Measuremen -


64.RNC er t of RB
Procedure
per RNC

VS.R99PSLoad.DL kbit/s Traffic -


Thruput.RNC Measuremen
t per RNC

VS.HSDPAPSLoad. kbit/s Traffic -


DLThruput.RNC Measuremen
t per RNC

VS.MBMSPSLoad. kbit/s Traffic -


DLThruput.RNC Measuremen
t per RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 790


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RRC.SuccConn % RRC (([VS.RRC.SuccConnEstab.O


Estab.Rate.Service connection rgConv]+
setup [VS.RRC.SuccConnEstab.Org
measurement Str]+
per RNC [VS.RRC.SuccConnEstab.Or-
gInt]+
[VS.RRC.SuccConnEstab.Org
Bkg]+
[VS.RRC.SuccConnEstab.Org
Subs]+
[VS.RRC.SuccConnEstab.Tr
mConv]+
[VS.RRC.SuccConnEstab.Tr
mStr]+
[VS.RRC.SuccConnEstab.Tr
mInt]+
[VS.RRC.SuccConnEstab.Tr
mBkg]+
[VS.RRC.SuccConnEstab.Org
HPSi]+
[VS.RRC.SuccConnEstab.Og
LPSig]+
[VS.RRC.SuccConnEstab.Tm
HPSi]+
[VS.RRC.SuccConnEstab.Tm
LPSi]+
[VS.RRC.SuccConnEstab.Res
t]))/
(([VS.RRC.AttConnEstab.Org
Conv]+
[VS.RRC.AttConnEstab.OrgS
tr]+
[VS.RRC.AttConnEstab.Or-
gInt]+
[VS.RRC.AttConnEstab.OrgB
kg]+
[VS.RRC.AttConnEstab.Org-
Subs]+
[VS.RRC.AttConnEstab.Trm
Conv]+
[VS.RRC.AttConnEstab.TrmS
tr]+
[VS.RRC.AttConnEstab.TrmI
nt]+
[VS.RRC.AttConnEstab.Trm
Bkg]+
[VS.RRC.AttConnEstab.OrgH

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 791


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

PSig]+
[VS.RRC.AttConnEstab.OrgL
PSig]+
[VS.RRC.AttConnEstab.TmH
PSig]+
[VS.RRC.AttConnEstab.TmL
PSig]+
[VS.RRC.AttConnEstab.Rest]
))*{100.00}

VS.RRC.SuccConn % RRC ([VS.RRC.SuccConnEstab.E


Estab.Rate.Other connection mg]+
setup [VS.RRC.SuccConnEstab.Cell
measurement Res]+
per RNC [VS.RRC.SuccConnEstab.Reg
]+
[VS.RRC.SuccConnEstab.De-
tach]+
[VS.RRC.SuccConnEstab.Un-
known])/
([VS.RRC.AttConnEstab.Emg
]+
[VS.RRC.AttConnEstab.CellR
es]+
[VS.RRC.AttConnEstab.Reg]
+[VS.RRC.AttConnEstab.De-
tach]+
[VS.RRC.AttConnEstab.Un-
known])*{100.00}

RAB.SuccEstabCSC % Measuremen [VS.RAB.SucEstCSConv0.32.


onv0.32.RNC.Rate t of CS RAB RNC]/
assignment [VS.RAB.AttEstCSConv0.32.
setup per RNC]*{100.00}
RNC

RAB.SuccEstabCSC % Measuremen [VS.RAB.SucEstCSConv32.6


onv32.64.RNC.Rate t of CS RAB 4.RNC]/
assignment [VS.RAB.AttEstCSConv32.64
setup per .RNC]*{100.00}
RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 792


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.SuccEstPS. % Measuremen (([RAB.SuccEstabPSNoQueui


RNC.Rate t of PS RAB ng.Bgrd]+
assignment [RAB.SuccEstabPSQueuing.B
setup per grd])+
RNC ([RAB.SuccEstabPSNoQueui
ng.Conv]+
[RAB.SuccEstabPSQueuing.C
onv])+
([RAB.SuccEstabPSNoQueui
ng.Intact]+
[RAB.SuccEstabPSQueuing.I
ntact])+
([RAB.SuccEstabPSQueuing.
Strm]+
[RAB.SuccEstabPSNoQueuin
g.Strm]))/
([RAB.AttEstabPS.Bgrd]+
[RAB.AttEstabPS.Strm]+
[RAB.AttEstabPS.Intact]+
[RAB.AttEstabPS.Conv])*
{100.00}

VS.SHO.Factor.RL none Soft ([VS.SHO.AS.1]+


Handover [VS.SHO.AS.2Softer]*{2}+
Measuremen [VS.SHO.AS.2Soft]*{2}+
t per RNC [VS.SHO.AS.3Softer]*{3}+
[VS.SHO.AS.3Soft]*{3}+
[VS.SHO.AS.3Soft2Softer]*
{3}+[VS.SHO.AS.4]*{4}+
[VS.SHO.AS.5]*{5}+
[VS.SHO.AS.6]*{6})/
([VS.SHO.AS.1]+
[VS.SHO.AS.2Softer]+
[VS.SHO.AS.2Soft]+
[VS.SHO.AS.3Softer]+
[VS.SHO.AS.3Soft]+
[VS.SHO.AS.3Soft2Softer]+
[VS.SHO.AS.4]+
[VS.SHO.AS.5]+
[VS.SHO.AS.6])-{1}

VS.SHO.Succ.Rate % Soft [VS.SHO.Succ]/


Handover [VS.SHO.Att.RNC]*{100.00}
Measuremen
t per RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 793


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.InterFreq.HHO.S % Hard [VS.HHO.InterFreq.Succ.RN


ucc.RNC.Rate Handover C]/
Measuremen [VS.HHO.InterFreq.Att.RNC]
t per RNC *{100.00}

VS.IRATHO.SuccC % Measuremen [VS.IRATHO.SuccCSOut.RN


SOut.RNC.Rate t related to C]/
CS IRA [VS.IRATHO.AttCSOut.RNC
handover per ]*{100.00}
RNC

VS.IRATHO.SuccP % Measuremen [VS.IRATHO.SuccPSOutUT


SOutUTRAN.RNC. t related to PS RAN.RNC]/
Rate IRA [VS.IRATHO.AttPSOutUTR
handover per AN.RNC]*{100.00}
RNC

VS.AMR.Call.Drop. % Measuremen [VS.RAB.Loss.CS.AMR.RNC


RNC.Rate t of RAB ]/
release [VS.RAB.SucEstCSConv0.32.
triggered by RNC]*{100.00}
UTRAN per
RNC

VS.VP.Call.Drop.R % Measuremen [VS.RAB.Loss.CS.Conv64K.


NC.Rate t of RAB RNC]/
release [VS.RAB.SucEstCSConv32.6
triggered by 4.RNC]*{100.00}
UTRAN per
RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 794


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.PS.Call.Drop.R % Measuremen (([VS.RAB.Loss.PS.RF.RNC]


NC.Rate t of RAB +
release [VS.RAB.Loss.PS.Abnorm.R
triggered by NC]))/
UTRAN per (([RAB.SuccEstabPSNoQueui
RNC ng.Bgrd]+
[RAB.SuccEstabPSQueuing.B
grd])+
([RAB.SuccEstabPSNoQueui
ng.Conv]+
[RAB.SuccEstabPSQueuing.C
onv])+
([RAB.SuccEstabPSNoQueui
ng.Intact]+
[RAB.SuccEstabPSQueuing.I
ntact])+
([RAB.SuccEstabPSQueuing.
Strm]+
[RAB.SuccEstabPSNoQueuin
g.Strm]))*{100.00}

KPI2 VS.HSDPA.MeanC none HSDPA [VS.HSDPA.MeanChThrough


hThroughput.Total- Measuremen put.TotalBytes]/({1024}*
MBytes t per cell {1024})

VS.HSDPA.UE.Mea numb HSDPA -


n.Cell er Measuremen
t per cell

VS.HSDPA.MeanC none HSDPA ([VS.HSDPA.MeanChThroug


hThroughput.To- Measuremen hput.TotalBytes]*{8.0}/
talMBps t per cell ({1024.0}*{1024.0}))/({GP}*
{60})

VS.HSDPA.RAB.Su % HSDPA [VS.HSDPA.RAB.SuccEs-


ccEstab.Rate Measuremen tab]/[VS.HSDPA.RAB.AttEs-
t per cell tab]*{100.00}

VS.HSDPA.ServCel % HSDPA [VS.HSDPA.SHO.CellChg.Su


lChg.Succ.Rate Measuremen ccOut]/
t per cell [VS.HSDPA.SHO.CellChg.At
tOut]*{100.00}

VS.HSDPA.HHO.In % HSDPA [VS.HSDPA.HHO.SuccOu-


traFreq.NoChR.Succ Measuremen tIntraFreq]/
.Rate t per cell [VS.HSDPA.HHO.AttOutIn-
traFreq]*{100.00}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 795


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.HSDPA.HHO.In % HSDPA [VS.HSDPA.HHO.SuccOu-


terFreq.NoChR.Succ Measuremen tInterFreq]/
.Rate t per cell [VS.HSDPA.HHO.AttOutIn-
terFreq]*{100.00}

VS.HSDPA.ChR.HS % HSDPA [VS.HSDPA.ChR.HSDSCHto


DSCHtoDCH.Succ. Measuremen DCH]/
Rate t per cell [VS.HSDPA.ChR.HSDSCHto
DCH.Att]*{100.00}

VS.HSDPA.ChR.D % HSDPA [VS.HSDPA.ChR.DCHtoHSD


CHtoHSDSCH.Succ Measuremen SCH]/
.Rate t per cell [VS.HSDPA.ChR.DCHtoHSD
SCH.Att]*{100.00}

VS.HSDPA.RAB.A % HSDPA ([VS.HSDPA.RAB.Loss.Abn


bnormRel.Rate Measuremen orm.NonRF]+
t per cell [VS.HSDPA.RAB.Loss.RF])/
([VS.HSDPA.RAB.Loss.In-
Activity]+
[VS.HSDPA.RAB.Loss.Abno
rm.NonRF]+
[VS.HSDPA.RAB.Loss.RF]+
[VS.HSDPA.RAB.Loss.Norm
]+
[VS.HSDPA.ChR.HSDSCHto
DCH]+
[VS.HSDPA.ChR.HSDSCHto
FACH]+
[VS.HSDPA.HHO.H2D.Suc-
cOutIntraFreq]+
[VS.HSDPA.HHO.H2D.Suc-
cOutInterFreq])*{100.00}

VS.HSUPA.RAB.Su % HSUPA [VS.HSUPA.RAB.SuccEs-


ccEstab.Rate Measuremen tab]/[VS.HSUPA.RAB.AttEs-
t per cell tab]*{100.00}

VS.HSUPA.EDCH. % HSUPA [VS.HSUPA.EDCH.SHO.Suc


SHO.Succ.Ratio Measuremen c]/
t per cell [VS.HSUPA.EDCH.SHO.Att]
*{100.00}

VS.HSUPA.SHO.Se % HSUPA [VS.HSUPA.SHO.ServCellCh


rvCellChg.Succ.Ra- Measuremen g.Succ]/
tio t per cell [VS.HSUPA.SHO.ServCellCh
g.Att]*{100.00}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 796


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.HSUPA.HHO.In % HSUPA [VS.HSUPA.HHO.InterFreq.


terFreq.NoChR.Succ Measuremen NoChR.Succ]/
.Ratio t per cell [VS.HSUPA.HHO.InterFreq.
NoChR.Att]*{100.00}

VS.HSUPA.RAB.A % HSUPA ([VS.HSUPA.RAB.Loss.Ab-


bnormRel.Rate Measuremen norm])/
t per cell ([VS.HSUPA.RAB.Loss.Ab-
norm]+
[VS.HSUPA.RAB.Loss.Norm
]+
[VS.HSUPA.ChR.IntraCell.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.IntraFreq.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.InterFreq.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.EDCHtoFA
CH.Succ])*{100.00}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.3.5 Traffic TopN Report

Report Type
Simple Report

NE Type
RNC

Object Type
UCell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 797


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

AMR VS.AMR.Ctrl.DL12. numb Measuremen -


12.2 2 er t of RB
Traffic Procedure
per cell

VS.RRC.SuccConn % RRC [RRC.SuccConnEstab.sum]/


Estab.Cell.Rate connection [VS.RRC.AttConnEstab.Cell]
setup *{100.00}
measurement
per cell

VS.HHO.InterFreq. % Hard [VS.HHO.InterFreq.SuccOut]/


Out.Cell.Rate Handover [VS.HHO.InterFreq.AttOut]*
Measuremen {100.00}
t per cell

VS.MeanTCP dBm Cell TX and -


RX Power
Measuremen
t per cell

VS.MAC.SRNCIub byte Traffic -


BytesPSInt.Tx Measuremen
t per cell

VS.MAC.SRNCIub byte Traffic -


BytesPSBkg.Tx Measuremen
t per cell

VS.MaxRTWP dBm Cell TX and -


RX Power
Measuremen
t per cell

VS.MinRTWP dBm Cell TX and -


RX Power
Measuremen
t per cell

VS.MaxTCP dBm Cell TX and -


RX Power
Measuremen
t per cell

VS.RB.DLConvCS. numb Measuremen -


64 er t of RB
Procedure
per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 798


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RB.DLInterPS. numb Measuremen -


64 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


128 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


144 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


384 er t of RB
Procedure
per cell

VS.RAB.SuccEstab % Measuremen [VS.RAB.SuccEstab.AMR]/


CS.AMR.Cell.Rate t of CS RAB [VS.RAB.AttEstab.AMR]*
assignment {100.00}
setup per cell

VS.RAB.SuccEstab % Measuremen [VS.RAB.SuccEstCS.Conv.


CS.Conv. t of CS RAB 64]/[VS.RAB.AttEstCS.Conv.
64.Cell.Rate assignment 64]*{100.00}
setup per cell

VS.RAB.SuccEstab % Measuremen ([VS.RAB.SuccEstabPS.Conv


PS.Cell.Rate t of PS RAB ]+[VS.RAB.SuccEstabPS.Str]
assignment +[VS.RAB.SuccEstabPS.In-
setup per cell ter]+
[VS.RAB.SuccEstabPS.Bkg])/
([VS.RAB.AttEstabPS.Conv]
+[VS.RAB.AttEstabPS.Str]+
[VS.RAB.AttEstabPS.Inter]+
[VS.RAB.AttEstabPS.Bkg])*
{100.00}

VS.SuccRBSetup.Ce % Measuremen [VS.SuccRBSetup]/


ll.Rate t of RB [VS.AttRBSetup]*{100.00}
Procedure
per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 799


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.IRATHO.SuccO % InterRAT [IRATHO.SuccOutCS]/


utCS.Cell.Rate Handover [IRATHO.AttOutCS]*
Measuremen {100.00}
t per cell

VS.CS.AMR.Call.D % Measuremen [VS.RAB.Loss.CS.AMR]/


rop.Cell.Rate t of RAB ([VS.RAB.Loss.CS.AMR]+
release [VS.RAB.Loss.CS.Norm.AM
triggered by R])*{100.00}
UTRAN per
cell

VS.CS.VP.Call.Dro % Measuremen [VS.RAB.Loss.CS.Conv64K]/


p.Cell.Rate t of RAB ([VS.RAB.Loss.CS.Conv64K]
release +[VS.Norm.Rel.CS.Conv.RB.
triggered by 64])*{100.00}
UTRAN per
cell

VS.PS.Call.Drop.Ce % Measuremen ([VS.RAB.Loss.PS.RF]+


ll.Rate t of RAB [VS.RAB.Loss.PS.Abnorm])/
release ([VS.RAB.Loss.PS.RF]+
triggered by [VS.RAB.Loss.PS.Abnorm]+
UTRAN per [VS.RAB.Loss.PS.Norm])*
cell {100.00}

VS.PCH.Utilization. % Traffic [VS.MAC.CRNCIubBytesPC


Cell.Rate Measuremen H.Tx]/
t per cell ([VS.CRNC.IUB.PCH.Band-
width]*{GP}*{60})*{100.00}

VS.FACH.Utilizatio % Traffic [VS.MAC.CRNCIubBytesFA


n.Cell.Rate Measuremen CH.Tx]/
t per cell ([VS.CRNC.IUB.FACH.Band
width]*{GP}*{60})*{100.00}

VS.RACH.Utilizatio % Traffic [VS.MAC.CRNCIubBytesRA


n.Cell.Rate Measuremen CH.Rx]/
t per cell ([VS.CRNC.IUB.RACH.Band
width]*{GP}*{60})*{100.00}

VP VS.RB.DLConvCS. numb Measuremen -


Traffic 64 er t of RB
Procedure
per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 800


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RRC.SuccConn % RRC [RRC.SuccConnEstab.sum]/


Estab.Cell.Rate connection [VS.RRC.AttConnEstab.Cell]
setup *{100.00}
measurement
per cell

VS.HHO.InterFreq. % Hard [VS.HHO.InterFreq.SuccOut]/


Out.Cell.Rate Handover [VS.HHO.InterFreq.AttOut]*
Measuremen {100.00}
t per cell

VS.MeanTCP dBm Cell TX and -


RX Power
Measuremen
t per cell

VS.MAC.SRNCIub byte Traffic -


BytesPSInt.Tx Measuremen
t per cell

VS.MAC.SRNCIub byte Traffic -


BytesPSBkg.Tx Measuremen
t per cell

VS.MaxRTWP dBm Cell TX and -


RX Power
Measuremen
t per cell

VS.MinRTWP dBm Cell TX and -


RX Power
Measuremen
t per cell

VS.MaxTCP dBm Cell TX and -


RX Power
Measuremen
t per cell

VS.AMR.Ctrl.DL12. numb Measuremen -


2 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


64 er t of RB
Procedure
per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 801


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RB.DLInterPS. numb Measuremen -


128 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


144 er t of RB
Procedure
per cell

VS.RAB.SuccEstab % Measuremen [VS.RAB.SuccEstab.AMR]/


CS.AMR.Cell.Rate t of CS RAB [VS.RAB.AttEstab.AMR]*
assignment {100.00}
setup per cell

VS.RAB.SuccEstab % Measuremen [VS.RAB.SuccEstCS.Conv.


CS.Conv. t of CS RAB 64]/[VS.RAB.AttEstCS.Conv.
64.Cell.Rate assignment 64]*{100.00}
setup per cell

VS.RAB.SuccEstab % Measuremen ([VS.RAB.SuccEstabPS.Conv


PS.Cell.Rate t of PS RAB ]+[VS.RAB.SuccEstabPS.Str]
assignment +[VS.RAB.SuccEstabPS.In-
setup per cell ter]+
[VS.RAB.SuccEstabPS.Bkg])/
([VS.RAB.AttEstabPS.Conv]
+[VS.RAB.AttEstabPS.Str]+
[VS.RAB.AttEstabPS.Inter]+
[VS.RAB.AttEstabPS.Bkg])*
{100.00}

VS.SuccRBSetup.Ce % Measuremen [VS.SuccRBSetup]/


ll.Rate t of RB [VS.AttRBSetup]*{100.00}
Procedure
per cell

VS.IRATHO.SuccO % InterRAT [IRATHO.SuccOutCS]/


utCS.Cell.Rate Handover [IRATHO.AttOutCS]*
Measuremen {100.00}
t per cell

VS.CS.AMR.Call.D % Measuremen [VS.RAB.Loss.CS.AMR]/


rop.Cell.Rate t of RAB ([VS.RAB.Loss.CS.AMR]+
release [VS.RAB.Loss.CS.Norm.AM
triggered by R])*{100.00}
UTRAN per
cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 802


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.CS.VP.Call.Dro % Measuremen [VS.RAB.Loss.CS.Conv64K]/


p.Cell.Rate t of RAB ([VS.RAB.Loss.CS.Conv64K]
release +[VS.Norm.Rel.CS.Conv.RB.
triggered by 64])*{100.00}
UTRAN per
cell

VS.PS.Call.Drop.Ce % Measuremen ([VS.RAB.Loss.PS.RF]+


ll.Rate t of RAB [VS.RAB.Loss.PS.Abnorm])/
release ([VS.RAB.Loss.PS.RF]+
triggered by [VS.RAB.Loss.PS.Abnorm]+
UTRAN per [VS.RAB.Loss.PS.Norm])*
cell {100.00}

VS.PCH.Utilization. % Traffic [VS.MAC.CRNCIubBytesPC


Cell.Rate Measuremen H.Tx]/
t per cell ([VS.CRNC.IUB.PCH.Band-
width]*{GP}*{60})*{100.00}

VS.FACH.Utilizatio % Traffic [VS.MAC.CRNCIubBytesFA


n.Cell.Rate Measuremen CH.Tx]/
t per cell ([VS.CRNC.IUB.FACH.Band
width]*{GP}*{60})*{100.00}

VS.RACH.Utilizatio % Traffic [VS.MAC.CRNCIubBytesRA


n.Cell.Rate Measuremen CH.Rx]/
t per cell ([VS.CRNC.IUB.RACH.Band
width]*{GP}*{60})*{100.00}

PS384 VS.RB.DLInterPS. numb Measuremen -


Traffic 384 er t of RB
Procedure
per cell

VS.RRC.SuccConn % RRC [RRC.SuccConnEstab.sum]/


Estab.Cell.Rate connection [VS.RRC.AttConnEstab.Cell]
setup *{100.00}
measurement
per cell

VS.HHO.InterFreq. % Hard [VS.HHO.InterFreq.SuccOut]/


Out.Cell.Rate Handover [VS.HHO.InterFreq.AttOut]*
Measuremen {100.00}
t per cell

VS.MeanTCP dBm Cell TX and -


RX Power
Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 803


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.MAC.SRNCIub byte Traffic -


BytesPSInt.Tx Measuremen
t per cell

VS.MAC.SRNCIub byte Traffic -


BytesPSBkg.Tx Measuremen
t per cell

VS.MaxRTWP dBm Cell TX and -


RX Power
Measuremen
t per cell

VS.MinRTWP dBm Cell TX and -


RX Power
Measuremen
t per cell

VS.MaxTCP dBm Cell TX and -


RX Power
Measuremen
t per cell

VS.AMR.Ctrl.DL12. numb Measuremen -


2 er t of RB
Procedure
per cell

VS.RB.DLConvCS. numb Measuremen -


64 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


64 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


128 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


144 er t of RB
Procedure
per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 804


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.SuccEstab % Measuremen [VS.RAB.SuccEstab.AMR]/


CS.AMR.Cell.Rate t of CS RAB [VS.RAB.AttEstab.AMR]*
assignment {100.00}
setup per cell

VS.RAB.SuccEstab % Measuremen [VS.RAB.SuccEstCS.Conv.


CS.Conv. t of CS RAB 64]/[VS.RAB.AttEstCS.Conv.
64.Cell.Rate assignment 64]*{100.00}
setup per cell

VS.RAB.SuccEstab % Measuremen ([VS.RAB.SuccEstabPS.Conv


PS.Cell.Rate t of PS RAB ]+[VS.RAB.SuccEstabPS.Str]
assignment +[VS.RAB.SuccEstabPS.In-
setup per cell ter]+
[VS.RAB.SuccEstabPS.Bkg])/
([VS.RAB.AttEstabPS.Conv]
+[VS.RAB.AttEstabPS.Str]+
[VS.RAB.AttEstabPS.Inter]+
[VS.RAB.AttEstabPS.Bkg])*
{100.00}

VS.SuccRBSetup.Ce % Measuremen [VS.SuccRBSetup]/


ll.Rate t of RB [VS.AttRBSetup]*{100.00}
Procedure
per cell

VS.IRATHO.SuccO % InterRAT [IRATHO.SuccOutCS]/


utCS.Cell.Rate Handover [IRATHO.AttOutCS]*
Measuremen {100.00}
t per cell

VS.CS.AMR.Call.D % Measuremen [VS.RAB.Loss.CS.AMR]/


rop.Cell.Rate t of RAB ([VS.RAB.Loss.CS.AMR]+
release [VS.RAB.Loss.CS.Norm.AM
triggered by R])*{100.00}
UTRAN per
cell

VS.CS.VP.Call.Dro % Measuremen [VS.RAB.Loss.CS.Conv64K]/


p.Cell.Rate t of RAB ([VS.RAB.Loss.CS.Conv64K]
release +[VS.Norm.Rel.CS.Conv.RB.
triggered by 64])*{100.00}
UTRAN per
cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 805


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.PS.Call.Drop.Ce % Measuremen ([VS.RAB.Loss.PS.RF]+


ll.Rate t of RAB [VS.RAB.Loss.PS.Abnorm])/
release ([VS.RAB.Loss.PS.RF]+
triggered by [VS.RAB.Loss.PS.Abnorm]+
UTRAN per [VS.RAB.Loss.PS.Norm])*
cell {100.00}

VS.PCH.Utilization. % Traffic [VS.MAC.CRNCIubBytesPC


Cell.Rate Measuremen H.Tx]/
t per cell ([VS.CRNC.IUB.PCH.Band-
width]*{GP}*{60})*{100.00}

VS.FACH.Utilizatio % Traffic [VS.MAC.CRNCIubBytesFA


n.Cell.Rate Measuremen CH.Tx]/
t per cell ([VS.CRNC.IUB.FACH.Band
width]*{GP}*{60})*{100.00}

VS.RACH.Utilizatio % Traffic [VS.MAC.CRNCIubBytesRA


n.Cell.Rate Measuremen CH.Rx]/
t per cell ([VS.CRNC.IUB.RACH.Band
width]*{GP}*{60})*{100.00}

HSDPA VS.HSDPA.MeanC none HSDPA [VS.HSDPA.MeanChThrough


Traffic hThroughput.Total- Measuremen put.TotalBytes]/({1024}*
MBytes t per cell {1024})

VS.HSDPA.Kbps.M none HSDPA {8}*


eanChThroughput Measuremen [VS.HSDPA.MeanChThrough
t per cell put.TotalBytes]/({GP}*{60}*
{1024})

VS.HSDPA.MeanC none HSDPA ([VS.HSDPA.MeanChThroug


hThroughput.To- Measuremen hput.TotalBytes]*{8.0}/
talMBps t per cell ({1024.0}*{1024.0}))/({GP}*
{60})

VS.HSDPA.UE.Mea numb HSDPA -


n.Cell er Measuremen
t per cell

VS.HSDPA.RAB.Su % HSDPA [VS.HSDPA.RAB.SuccEs-


ccEstab.Rate Measuremen tab]/[VS.HSDPA.RAB.AttEs-
t per cell tab]*{100.00}

VS.HSDPA.ChR.HS % HSDPA [VS.HSDPA.ChR.HSDSCHto


DSCHtoDCH.Succ. Measuremen DCH]/
Rate t per cell [VS.HSDPA.ChR.HSDSCHto
DCH.Att]*{100.00}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 806


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.HSDPA.ChR.D % HSDPA [VS.HSDPA.ChR.DCHtoHSD


CHtoHSDSCH.Succ Measuremen SCH]/
.Rate t per cell [VS.HSDPA.ChR.DCHtoHSD
SCH.Att]*{100.00}

VS.HSDPA.MAC- none HSDPA [VS.HSDPA.MACDSuccStp-


DAttStpPerCell Measuremen PerCell]+
t per cell [VS.HSDPA.MACDFailStp-
PerCell]

VS.HSDPA.RAB.Fa none HSDPA [VS.HSDPA.RAB.AttEstab]-


ilEstab Measuremen [VS.HSDPA.RAB.SuccEstab]
t per cell

VS.HSDPA.ChR.FA none HSDPA [VS.HSDPA.ChR.FACHtoHS


CHtoHSDSCH.Fail Measuremen DSCH.Att]-
t per cell [VS.HSDPA.ChR.FACH-
toHSDSCH]

VS.HSDPA.ChR.HS none HSDPA [VS.HSDPA.ChR.HSDSCHto


DSCHtoFACH.Fail Measuremen FACH.Att]-
t per cell [VS.HSDPA.ChR.HSDSCHto
FACH]

VS.HSDPA.ChR.HS none HSDPA [VS.HSDPA.ChR.HSDSCHto


DSCHtoDCH.Fail Measuremen DCH.Att]-
t per cell [VS.HSDPA.ChR.HSDSCHto
DCH]

VS.HSDPA.ChR.D none HSDPA [VS.HSDPA.ChR.DCHtoHSD


CHtoHSDSCH.Fail Measuremen SCH.Att]-
t per cell [VS.HSDPA.ChR.DCHtoHSD
SCH]

VS.HSDPA.MACD- times HSDPA -


SuccStpPerCell Measuremen
t per cell

HSDPA VS.HSUPA.MeanC none HSUPA [VS.HSUPA.MeanChThrough


Traffic hThroughput.Total- Measuremen put.TotalBytes]/({1024}*
MBytes t per cell {1024})

VS.HSUPA.Kbps.M none HSUPA {8}*


eanChThroughput Measuremen [VS.HSUPA.MeanChThrough
t per cell put.TotalBytes]/({GP}*{60}*
{1024})

VS.HSUPA.UE.Mea numb HSUPA -


n.Cell er Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 807


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.HSUPA.RAB.Su % HSUPA [VS.HSUPA.RAB.SuccEs-


ccEstab.Rate Measuremen tab]/[VS.HSUPA.RAB.AttEs-
t per cell tab]*{100.00}

VS.HSUPA.RAB.Fa none HSUPA [VS.HSUPA.RAB.AttEstab]-


ilEstab Measuremen [VS.HSUPA.RAB.SuccEstab]
t per cell

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.3.6 VIC KPI Report

Report Type
Simple Report

NE Type
RNC

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

VIC KPI VS.Call.Drop.Cell none Measuremen ([VS.RAB.Loss.CS.RF]+


t of RAB [VS.RAB.Loss.CS.Abnorm])+
release ([VS.RAB.Loss.PS.RF]+
triggered by [VS.RAB.Loss.PS.Abnorm])
UTRAN per
cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 808


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RRC.SuccConn % RRC [RRC.SuccConnEstab.sum]/


Estab.Cell.Rate connection [VS.RRC.AttConnEstab.Cell]
setup *{100.00}
measurement
per cell

VS.HHO.InterFreq. % Hard [VS.HHO.InterFreq.SuccOut]/


Out.Cell.Rate Handover [VS.HHO.InterFreq.AttOut]*
Measuremen {100.00}
t per cell

VS.MeanTCP dBm Cell TX and -


RX Power
Measuremen
t per cell

VS.MAC.SRNCIub byte Traffic -


BytesPSInt.Tx Measuremen
t per cell

VS.MAC.SRNCIub byte Traffic -


BytesPSBkg.Tx Measuremen
t per cell

VS.MaxRTWP dBm Cell TX and -


RX Power
Measuremen
t per cell

VS.MinRTWP dBm Cell TX and -


RX Power
Measuremen
t per cell

VS.MaxTCP dBm Cell TX and -


RX Power
Measuremen
t per cell

VS.AMR.Ctrl.DL12. numb Measuremen -


2 er t of RB
Procedure
per cell

VS.RB.DLConvCS. numb Measuremen -


64 er t of RB
Procedure
per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 809


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RB.DLInterPS. numb Measuremen -


64 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


128 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


144 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


384 er t of RB
Procedure
per cell

VS.RAB.SuccEstab % Measuremen [VS.RAB.SuccEstab.AMR]/


CS.AMR.Cell.Rate t of CS RAB [VS.RAB.AttEstab.AMR]*
assignment {100.00}
setup per cell

VS.RAB.SuccEstab % Measuremen [VS.RAB.SuccEstCS.Conv.


CS.Conv. t of CS RAB 64]/[VS.RAB.AttEstCS.Conv.
64.Cell.Rate assignment 64]*{100.00}
setup per cell

VS.RAB.SuccEstab % Measuremen ([VS.RAB.SuccEstabPS.Conv


PS.Cell.Rate t of PS RAB ]+[VS.RAB.SuccEstabPS.Str]
assignment +[VS.RAB.SuccEstabPS.In-
setup per cell ter]+
[VS.RAB.SuccEstabPS.Bkg])/
([VS.RAB.AttEstabPS.Conv]
+[VS.RAB.AttEstabPS.Str]+
[VS.RAB.AttEstabPS.Inter]+
[VS.RAB.AttEstabPS.Bkg])*
{100.00}

VS.SuccRBSetup.Ce % Measuremen [VS.SuccRBSetup]/


ll.Rate t of RB [VS.AttRBSetup]*{100.00}
Procedure
per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 810


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.IRATHO.SuccO % InterRAT [IRATHO.SuccOutCS]/


utCS.Cell.Rate Handover [IRATHO.AttOutCS]*
Measuremen {100.00}
t per cell

VS.CS.AMR.Call.D % Measuremen [VS.RAB.Loss.CS.AMR]/


rop.Cell.Rate t of RAB ([VS.RAB.Loss.CS.AMR]+
release [VS.RAB.Loss.CS.Norm.AM
triggered by R])*{100.00}
UTRAN per
cell

VS.CS.VP.Call.Dro % Measuremen [VS.RAB.Loss.CS.Conv64K]/


p.Cell.Rate t of RAB ([VS.RAB.Loss.CS.Conv64K]
release +[VS.Norm.Rel.CS.Conv.RB.
triggered by 64])*{100.00}
UTRAN per
cell

VS.PS.Call.Drop.Ce % Measuremen ([VS.RAB.Loss.PS.RF]+


ll.Rate t of RAB [VS.RAB.Loss.PS.Abnorm])/
release ([VS.RAB.Loss.PS.RF]+
triggered by [VS.RAB.Loss.PS.Abnorm]+
UTRAN per [VS.RAB.Loss.PS.Norm])*
cell {100.00}

VS.PCH.Utilization. % Traffic [VS.MAC.CRNCIubBytesPC


Cell.Rate Measuremen H.Tx]/
t per cell ([VS.CRNC.IUB.PCH.Band-
width]*{GP}*{60})*{100.00}

VS.FACH.Utilizatio % Traffic [VS.MAC.CRNCIubBytesFA


n.Cell.Rate Measuremen CH.Tx]/
t per cell ([VS.CRNC.IUB.FACH.Band
width]*{GP}*{60})*{100.00}

VS.RACH.Utilizatio % Traffic [VS.MAC.CRNCIubBytesRA


n.Cell.Rate Measuremen CH.Rx]/
t per cell ([VS.CRNC.IUB.RACH.Band
width]*{GP}*{60})*{100.00}

VS.HSDPA.RAB.Su % HSDPA [VS.HSDPA.RAB.SuccEs-


ccEstab.Rate Measuremen tab]/[VS.HSDPA.RAB.AttEs-
t per cell tab]*{100.00}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 811


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.HSDPA.RAB.A % HSDPA ([VS.HSDPA.RAB.Loss.Abn


bnormRel.Rate Measuremen orm.NonRF]+
t per cell [VS.HSDPA.RAB.Loss.RF])/
([VS.HSDPA.RAB.Loss.In-
Activity]+
[VS.HSDPA.RAB.Loss.Abno
rm.NonRF]+
[VS.HSDPA.RAB.Loss.RF]+
[VS.HSDPA.RAB.Loss.Norm
]+
[VS.HSDPA.ChR.HSDSCHto
DCH]+
[VS.HSDPA.ChR.HSDSCHto
FACH]+
[VS.HSDPA.HHO.H2D.Suc-
cOutIntraFreq]+
[VS.HSDPA.HHO.H2D.Suc-
cOutInterFreq])*{100.00}

VS.HSDPA.ServCel % HSDPA [VS.HSDPA.SHO.CellChg.Su


lChg.Succ.Rate Measuremen ccOut]/
t per cell [VS.HSDPA.SHO.CellChg.At
tOut]*{100.00}

VS.HSDPA.ChR.HS % HSDPA [VS.HSDPA.ChR.HSDSCHto


DSCHtoDCH.Succ. Measuremen DCH]/
Rate t per cell [VS.HSDPA.ChR.HSDSCHto
DCH.Att]*{100.00}

VS.HSDPA.ChR.D % HSDPA [VS.HSDPA.ChR.DCHtoHSD


CHtoHSDSCH.Succ Measuremen SCH]/
.Rate t per cell [VS.HSDPA.ChR.DCHtoHSD
SCH.Att]*{100.00}

VS.HSDPA.HHO.In % HSDPA [VS.HSDPA.HHO.SuccOu-


traFreq.NoChR.Succ Measuremen tIntraFreq]/
.Rate t per cell [VS.HSDPA.HHO.AttOutIn-
traFreq]*{100.00}

VS.HSDPA.HHO.In % HSDPA [VS.HSDPA.HHO.SuccOu-


terFreq.NoChR.Succ Measuremen tInterFreq]/
.Rate t per cell [VS.HSDPA.HHO.AttOutIn-
terFreq]*{100.00}

VS.HSUPA.RAB.Su % HSUPA [VS.HSUPA.RAB.SuccEs-


ccEstab.Rate Measuremen tab]/[VS.HSUPA.RAB.AttEs-
t per cell tab]*{100.00}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 812


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.HSUPA.RAB.A % HSUPA ([VS.HSUPA.RAB.Loss.Ab-


bnormRel.Rate Measuremen norm])/
t per cell ([VS.HSUPA.RAB.Loss.Ab-
norm]+
[VS.HSUPA.RAB.Loss.Norm
]+
[VS.HSUPA.ChR.IntraCell.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.IntraFreq.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.InterFreq.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.EDCHtoFA
CH.Succ])*{100.00}

VS.HSUPA.EDCH. % HSUPA [VS.HSUPA.EDCH.SHO.Suc


SHO.Succ.Ratio Measuremen c]/
t per cell [VS.HSUPA.EDCH.SHO.Att]
*{100.00}

VS.HSUPA.SHO.Se % HSUPA [VS.HSUPA.SHO.ServCellCh


rvCellChg.Succ.Ra- Measuremen g.Succ]/
tio t per cell [VS.HSUPA.SHO.ServCellCh
g.Att]*{100.00}

VS.HSUPA.HHO.In % HSUPA [VS.HSUPA.HHO.InterFreq.


terFreq.NoChR.Succ Measuremen NoChR.Succ]/
.Ratio t per cell [VS.HSUPA.HHO.InterFreq.
NoChR.Att]*{100.00}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.4 Network shift Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 813


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

21.4.1 Call TopN Report

Report Type
Simple Report

NE Type
RNC

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

CS Call VS.CS.Call.Drop.Ce numb Measuremen [VS.RAB.Loss.CS.RF]+


Drop ll er t of RAB [VS.RAB.Loss.CS.Abnorm]
Cells release
triggered by
UTRAN per
cell

VS.RAB.SuccEstab none Measuremen [VS.RAB.SuccEstabCS.Conv]


CS.Cell t of CS RAB +[VS.RAB.SuccEstabCS.Str]
assignment
setup per cell

VS.RAB.RelReqCS. numb Measuremen -


OM er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.RelReqCS. numb Measuremen -


RABPreempt er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.RelReqCS. numb Measuremen -


UTRANgen er t of RAB
release
triggered by
UTRAN per
cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 814


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.Loss.CS.R numb Measuremen -


F.RLCRst er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.CS.R numb Measuremen -


F.ULSync er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.CS.R numb Measuremen -


F.UuNoReply er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.CS.R numb Measuremen -


F.Oth er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.CS.A numb Measuremen -


al2Loss er t of RAB
release
triggered by
UTRAN per
cell

VS.Call.Drop.CS.Ot numb Measuremen [VS.RAB.Loss.CS.Abnorm]-


her er t of RAB [VS.RAB.RelReqCS.OM]-
release [VS.RAB.RelReqCS.UTRAN
triggered by gen]-
UTRAN per [VS.RAB.RelReqCS.RAB-
cell Preempt]-
[VS.RAB.Loss.CS.Aal2Loss]

Cell VS.Cell.UnavailTim s Measuremen -


Unavaila e.OM t related to
ble Algorithm
per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 815


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.Cell.UnavailTim % Measuremen [VS.Cell.UnavailTime.OM]*


e.OM.Rate t related to {100}/({GP}*{60})*{100.00}
Algorithm
per cell

VP Call VS.CS.VP.Call.Dro none Measuremen [VS.RAB.Loss.CS.Conv64K]


Drops p.Cell t of RAB
release
triggered by
UTRAN per
cell

AMR VS.CS.AMR.Call.D none Measuremen [VS.RAB.Loss.CS.AMR]


Call rop.Cell t of RAB
Drops release
triggered by
UTRAN per
cell

PS Drop VS.PS.Call.Drop.Ce numb Measuremen [VS.RAB.Loss.PS.RF]+


Cells ll er t of RAB [VS.RAB.Loss.PS.Abnorm]
release
triggered by
UTRAN per
cell

VS.RAB.SuccEstPS. none Measuremen [VS.RAB.SuccEstabPS.Conv]


Cell t of PS RAB +[VS.RAB.SuccEstabPS.Str]+
assignment [VS.RAB.SuccEstabPS.Inter]
setup per cell +[VS.RAB.SuccEstabPS.Bkg]

VS.RAB.RelReqPS. numb Measuremen -


OM er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.RelReqPS. numb Measuremen -


RABPreempt er t of RAB
release
triggered by
UTRAN per
cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 816


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.RelReqPS. numb Measuremen -


UTRANgen er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.PS.R numb Measuremen -


F.RLCRst er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.PS.R numb Measuremen -


F.ULSync er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.PS.R numb Measuremen -


F.UuNoReply er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.PS.R numb Measuremen -


F.Oth er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.PS.G numb Measuremen -


TPULoss er t of RAB
release
triggered by
UTRAN per
cell

VS.Call.Drop.PS.Ot numb Measuremen [VS.RAB.Loss.PS.Abnorm]-


her er t of RAB [VS.RAB.RelReqPS.OM]-
release [VS.RAB.RelReqPS.RAB-
triggered by Preempt]-
UTRAN per [VS.RAB.Loss.PS.GTPU-
cell Loss]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 817


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

RRC Fail VS.RRC.FailConnE times RRC [VS.RRC.AttConnEstab.Cell]-


stab.Cell connection [RRC.SuccConnEstab.sum]
setup
measurement
per cell

VS.RRC.AttConEst. none RRC [VS.RRC.AttConEst.DCH]+


Cell connection [VS.RRC.AttConEst.CCH]
setup
measurement
per cell

VS.RRC.Rej.RL.Fai times RRC -


l connection
reject
measurement
per cell

VS.RRC.Rej.TNL.F times RRC -


ail connection
reject
measurement
per cell

VS.RRC.Rej.Power. times RRC -


Cong connection
reject
measurement
per cell

VS.RRC.Rej.UL.CE times RRC -


.Cong connection
reject
measurement
per cell

VS.RRC.Rej.DL.CE times RRC -


.Cong connection
reject
measurement
per cell

VS.RRC.Rej.Code.C times RRC -


ong connection
reject
measurement
per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 818


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RRC.Rej.Other. times RRC [RRC.FailConnEstab.Cong]-


Cong connection [VS.RRC.Rej.Power.Cong]-
reject [VS.RRC.Rej.Code.Cong]-
measurement [VS.RRC.Rej.UL.CE.Cong]-
per cell [VS.RRC.Rej.DL.CE.Cong]

RRC.FailConnEstab. times RRC -


NoReply connection
reject
measurement
per cell

CS RAB VS.RAB.FailEstabC numb Measuremen [VS.RAB.AttEstabCS.Conv]+


FAIL S.Cell er t of CS RAB [VS.RAB.AttEstabCS.Str]-
assignment [VS.RAB.SuccEstabCS.Conv]
setup per cell -[VS.RAB.SuccEstabCS.Str]

VS.RAB.AttEstabC numb Measuremen [VS.RAB.AttEstabCS.Conv]+


S.Cell er t of CS RAB [VS.RAB.AttEstabCS.Str]
assignment
setup per cell

VS.RAB.FailEstabC numb Measuremen -


S.TNL er t of CS RAB
assignment
failure per
cell

VS.RAB.FailEstCS. numb Measuremen -


Relo er t of CS RAB
assignment
failure per
cell

VS.RAB.FailEstCS. numb Measuremen -


RIPFail er t of CS RAB
assignment
failure per
cell

VS.RAB.FailEstCs. numb Measuremen -


Power.Cong er t of CS RAB
assignment
failure per
cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 819


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.FailEstCs. numb Measuremen -


ULCE.Cong er t of CS RAB
assignment
failure per
cell

VS.RAB.FailEstCs. numb Measuremen -


DLCE.Cong er t of CS RAB
assignment
failure per
cell

VS.RAB.FailEstCs. numb Measuremen -


Code.Cong er t of CS RAB
assignment
failure per
cell

VS.RAB.FailEstCs.I numb Measuremen -


UB.Band er t of CS RAB
assignment
failure per
cell

VS.RAB.FailEstabC numb Measuremen [VS.RAB.FailEstabCS.RNL]-


S.RNL.Other er t of CS RAB [VS.RAB.FailEstCS.Relo]-
assignment [VS.RAB.FailEstCS.RIPFail]-
failure per [VS.RAB.FailEstabCS.Cong]
cell

VS.RAB.FailEstabC none Measuremen ([VS.RAB.AttEstabCS.Conv]


S.other.CELL t of CS RAB +[VS.RAB.AttEstabCS.Str]-
assignment [VS.RAB.SuccEstabCS.Conv]
setup per cell -[VS.RAB.SuccEstabCS.Str])-
[VS.RAB.FailEstabCS.RNL]-
[VS.RAB.FailEstabCS.TNL]

PS RAB VS.RAB.FailEstabP numb Measuremen ([VS.RAB.AttEstabPS.Conv]


FAIL S.Cell er t of PS RAB +[VS.RAB.AttEstabPS.Str]+
assignment [VS.RAB.AttEstabPS.Inter]+
setup per cell [VS.RAB.AttEstabPS.Bkg])-
([VS.RAB.SuccEstabPS.Conv
]+[VS.RAB.SuccEstabPS.Str]
+[VS.RAB.SuccEstabPS.In-
ter]+
[VS.RAB.SuccEstabPS.Bkg])

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 820


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.AttEstabPS numb Measuremen [VS.RAB.AttEstabPS.Conv]+


.Cell er t of PS RAB [VS.RAB.AttEstabPS.Str]+
assignment [VS.RAB.AttEstabPS.Inter]+
setup per cell [VS.RAB.AttEstabPS.Bkg]

VS.RAB.FailEstPS. numb Measuremen -


TNL er t of PS RAB
assignment
failure per
cell

VS.RAB.FailEstPS. numb Measuremen -


RIPFail er t of PS RAB
assignment
failure per
cell

VS.RAB.FailEstPS. numb Measuremen -


Par er t of PS RAB
assignment
failure per
cell

VS.RAB.FailEstPS. numb Measuremen -


Relo er t of PS RAB
assignment
failure per
cell

VS.RAB.FailEstPs.P numb Measuremen -


ower.Cong er t of PS RAB
assignment
failure per
cell

VS.RAB.FailEstPs. numb Measuremen -


Code.Cong er t of PS RAB
assignment
failure per
cell

VS.RAB.FailEstPs. numb Measuremen -


ULCE.Cong er t of PS RAB
assignment
failure per
cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 821


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.FailEstPs. numb Measuremen -


DLCE.Cong er t of PS RAB
assignment
failure per
cell

VS.RAB.FailEstPs.I numb Measuremen -


UB.Band er t of PS RAB
assignment
failure per
cell

VS.RAB.FlEstPS.R numb Measuremen [VS.RAB.FailEstPS.RNL]-


NL.Other er t of PS RAB [VS.RAB.FailEstPS.RIPFail]-
assignment [VS.RAB.FailEstPS.Par]-
failure per [VS.RAB.FailEstPS.Relo]-
cell [VS.RAB.FailEstPS.Unsp]

VS.RAB.FailEstabP numb Measuremen (([VS.RAB.AttEstabPS.Conv]


S.Other.Cell er t of PS RAB +[VS.RAB.AttEstabPS.Str]+
assignment [VS.RAB.AttEstabPS.Inter]+
setup per cell [VS.RAB.AttEstabPS.Bkg])-
([VS.RAB.SuccEstabPS.Conv
]+[VS.RAB.SuccEstabPS.Str]
+[VS.RAB.SuccEstabPS.In-
ter]+
[VS.RAB.SuccEstabPS.Bkg]))
-[VS.RAB.FailEstPS.TNL]-
[VS.RAB.FailEstPS.RNL]

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.4.2 Cluster KPI Report

Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 822


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

NE Type
RNC

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Traffic VS.AMR.Ctrl.DL12. numb Measuremen -


(cluster) 2 er t of RB
Procedure
per cell

VS.RB.DLConvCS. numb Measuremen -


64 er t of RB
Procedure
per cell

PS.Inter.KByte.DL. none Measuremen ([VS.PS.Int.DL.8.Thruput]/


Throughput t related to ({1024}*{8}))+
throughput ([VS.PS.Int.DL.64.Thruput]/
per cell ({1024}*{8}))+
([VS.PS.Int.DL.128.Thruput]/
({1024}*{8}))+
([VS.PS.Int.DL.384.Thruput]/
({1024}*{8}))

PS.Bkg.KByte.DL.T none Measuremen ([VS.PS.Bkg.DL.8.Thruput]/


hroughput t related to ({1024}*{8}))+
throughput ([VS.PS.Bkg.DL.64.Thruput]/
per cell ({1024}*{8}))+
([VS.PS.Bkg.DL.
128.Thruput]/({1024}*{8}))+
([VS.PS.Bkg.DL.
384.Thruput]/({1024}*{8}))

VS.HSDPA.MeanC none HSDPA [VS.HSDPA.MeanChThrough


hThroughput.Total- Measuremen put.TotalBytes]/({1024}*
MBytes t per cell {1024})

VS.AMR.Call.Dura- none Measuremen ([VS.AMR.Ctrl.DL12.2]*


tion t of RB {60}*{60})/
Procedure [VS.RAB.SuccEstab.AMR]
per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 823


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Through VS.HSDPA.Kbps.M none HSDPA {8}*


put eanChThroughput Measuremen [VS.HSDPA.MeanChThrough
(cluster) t per cell put.TotalBytes]/({GP}*{60}*
{1024})

VS.PS.Throughput. none Measuremen ([VS.PS.Bkg.DL.64.Thruput]/


DL64.bps t related to [VS.PS.Bkg.DL.64.Times])+
throughput ([VS.PS.Int.DL.64.Thruput]/
per cell [VS.PS.Int.DL.64.Times])

VS.PS.Throughput. none Measuremen ([VS.PS.Bkg.DL.


DL128.bps t related to 128.Thruput]/[VS.PS.Bkg.DL.
throughput 128.Times])+([VS.PS.Int.DL.
per cell 128.Thruput]/[VS.PS.Int.DL.
128.Times])

VS.PS.Throughput. none Measuremen ([VS.PS.Bkg.DL.


DL384.bps t related to 384.Thruput]/[VS.PS.Bkg.DL.
throughput 384.Times])+([VS.PS.Int.DL.
per cell 384.Thruput]/[VS.PS.Int.DL.
384.Times])

VS.PS.Throughput. none Measuremen ([VS.PS.Bkg.UL.64.Thruput]/


UL64.bps t related to [VS.PS.Bkg.UL.64.Times])+
throughput ([VS.PS.Int.UL.64.Thruput]/
per cell [VS.PS.Int.UL.64.Times])

VS.PS.Throughput. none Measuremen ([VS.PS.Bkg.UL.


UL128.bps t related to 128.Thruput]/[VS.PS.Bkg.UL.
throughput 128.Times])+([VS.PS.Int.UL.
per cell 128.Thruput]/[VS.PS.Int.UL.
128.Times])

VS.PS.Throughput. none Measuremen ([VS.PS.Bkg.UL.


UL384.bps t related to 384.Thruput]/[VS.PS.Bkg.UL.
throughput 384.Times])+([VS.PS.Int.UL.
per cell 384.Thruput]/[VS.PS.Int.UL.
384.Times])

Access Call.Setup.Success. % RRC (([RRC.SuccConnEstab.sum])


(cluster) Rate.AMR connection /
setup ([VS.RRC.AttConnEstab.Cell]
measurement ))*
per cell ([VS.RAB.SuccEstab.AMR]/
[VS.RAB.AttEstab.AMR])

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 824


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Call.Setup.Success. % RRC (([RRC.SuccConnEstab.sum])


Rate.VP connection /
setup ([VS.RRC.AttConnEstab.Cell]
measurement ))*
per cell ([VS.RAB.SuccEstCS.Conv.
64]/[VS.RAB.AttEstCS.Conv.
64])

Call.Setup.Success. % RRC (([RRC.SuccConnEstab.sum])


Rate.AMR_VP connection /
setup ([VS.RRC.AttConnEstab.Cell]
measurement ))*
per cell (([VS.RAB.SuccEstab.AMR]
+[VS.RAB.SuccEstCS.Conv.
64])/
([VS.RAB.AttEstab.AMR]+
[VS.RAB.AttEstCS.Conv.
64]))

Call.Setup.Success. % RRC (([RRC.SuccConnEstab.sum])


Rate.PS connection /
setup ([VS.RRC.AttConnEstab.Cell]
measurement ))*
per cell (([VS.RAB.SuccEstabPS.Con
v]+
[VS.RAB.SuccEstabPS.Str]+
[VS.RAB.SuccEstabPS.Inter]
+
[VS.RAB.SuccEstabPS.Bkg])/
([VS.RAB.AttEstabPS.Conv]
+[VS.RAB.AttEstabPS.Str]+
[VS.RAB.AttEstabPS.Inter]+
[VS.RAB.AttEstabPS.Bkg]))

RRC.Setup.Success. % RRC ([RRC.SuccConnEstab.Og-


Rate.Conv connection ConvCall]+
setup [RRC.SuccConnEstab.TmCon
measurement vCall])/
per cell ([RRC.AttConnEstab.TmCon
vCall]+
[RRC.AttConnEstab.Org-
ConvCall])

RRC.Setup.Success. none RRC [RRC.SuccConnEstab.Og-


Conv connection ConvCall]+
setup [RRC.SuccConnEstab.TmCon
measurement vCall]
per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 825


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

RRC.Setup.Attempt. none RRC [RRC.AttConnEstab.TmConv


Conv connection Call]+
setup [RRC.AttConnEstab.Org-
measurement ConvCall]
per cell

RRC.Setup.Success. % RRC ([RRC.SuccConnEstab.OrgStr


Rate.Str connection Call]+
setup [RRC.SuccConnEstab.TmStr
measurement Call])/
per cell ([RRC.AttConnEstab.TmStrC
all]+
[RRC.AttConnEstab.OrgStr-
Call])

RRC.Setup.Success. none RRC [RRC.SuccConnEstab.OrgStr-


Str connection Call]+
setup [RRC.SuccConnEstab.TmStr
measurement Call]
per cell

RRC.Setup.Attempt. none RRC [RRC.AttConnEstab.TmStrCa


Str connection ll]+
setup [RRC.AttConnEstab.OrgStr-
measurement Call]
per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 826


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

RRC.Setup.Success. % RRC ([RRC.SuccConnEstab.OrgItr-


Rate.BESer connection Call]+
setup [RRC.SuccConnEstab.OrgBk
measurement gCall]+
per cell [RRC.SuccConnEstab.TmItr-
Call]+
[RRC.SuccConnEstab.TmBkg
Call]+
[RRC.SuccConnEstab.OgHhP
rSig]+
[RRC.SuccConnEstab.TmHhP
rSig])/
([RRC.AttConnEstab.TmIn-
terCall]+
[RRC.AttConnEstab.TmBkgC
all]+[RRC.AttConnEstab.Or-
gInterCall]+
[RRC.AttConnEstab.OrgBkg-
Call]+
[RRC.AttConnEstab.OgHhPr-
Sig]+
[RRC.AttConnEstab.TmHhPr
Sig])

RRC.Setup.Success. none RRC [RRC.SuccConnEstab.OrgItr-


BESer connection Call]+
setup [RRC.SuccConnEstab.OrgBk
measurement gCall]+
per cell [RRC.SuccConnEstab.TmItr-
Call]+
[RRC.SuccConnEstab.TmBkg
Call]+
[RRC.SuccConnEstab.OgHhP
rSig]+
[RRC.SuccConnEstab.TmHhP
rSig]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 827


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

RRC.Setup.Attempt. none RRC [RRC.AttConnEstab.TmInter-


BESer connection Call]+
setup [RRC.AttConnEstab.TmBkgC
measurement all]+[RRC.AttConnEstab.Or-
per cell gInterCall]+
[RRC.AttConnEstab.OrgBkg-
Call]+
[RRC.AttConnEstab.OgHhPr-
Sig]+
[RRC.AttConnEstab.TmHhPr
Sig]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 828


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RRC.SuccConn % RRC ([RRC.SuccConnEstab.Emg-


Estab.Other_ORO.R connection Call]+
ate.Cell setup [RRC.SuccConnEstab.IRAT-
measurement CelRes]+
per cell [RRC.SuccConnEstab.IRATC
CO]+
[RRC.SuccConnEstab.Reg]+
[RRC.SuccConnEstab.Detach]
+[RRC.SuccConnEstab.Un-
kown]+
[RRC.SuccConnEstab.Org-
SubCall]+
[RRC.SuccConnEstab.OgLwP
rSig]+
[RRC.SuccConnEstab.TmLw
PrSig]+
[RRC.SuccConnEstab.CallRe-
Est])/
([RRC.AttConnEstab.Emg-
Call]+
[RRC.AttConnEstab.IRAT-
CelRes]+
[RRC.AttConnEstab.IRATC-
CO]+
[RRC.AttConnEstab.Reg]+
[RRC.AttConnEstab.Detach]+
[RRC.AttConnEstab.Un-
known]+
[RRC.AttConnEstab.OgSub-
Call]+
[RRC.AttConnEstab.OgLwPr-
Sig]+
[RRC.AttConnEstab.TmLwPr
Sig]+
[RRC.AttConnEstab.CallRe-
Est])

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 829


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

RRC.SuccConnEsta none RRC [RRC.SuccConnEstab.Emg-


b.Other_ORO.Cell connection Call]+
setup [RRC.SuccConnEstab.IRAT-
measurement CelRes]+
per cell [RRC.SuccConnEstab.IRATC
CO]+
[RRC.SuccConnEstab.Reg]+
[RRC.SuccConnEstab.Detach]
+[RRC.SuccConnEstab.Un-
kown]+
[RRC.SuccConnEstab.Org-
SubCall]+
[RRC.SuccConnEstab.OgLwP
rSig]+
[RRC.SuccConnEstab.TmLw
PrSig]+
[RRC.SuccConnEstab.CallRe-
Est]

RRC.AttConnEstab. none RRC [RRC.AttConnEstab.Emg-


Other_ORO.Cell connection Call]+
setup [RRC.AttConnEstab.IRAT-
measurement CelRes]+
per cell [RRC.AttConnEstab.IRATC-
CO]+
[RRC.AttConnEstab.Reg]+
[RRC.AttConnEstab.Detach]+
[RRC.AttConnEstab.Un-
known]+
[RRC.AttConnEstab.OgSub-
Call]+
[RRC.AttConnEstab.OgLwPr-
Sig]+
[RRC.AttConnEstab.TmLwPr
Sig]+
[RRC.AttConnEstab.CallRe-
Est]

VS.RAB.SuccEstab % Measuremen [VS.RAB.SuccEstab.AMR]/


CS.AMR.Cell.Rate t of CS RAB [VS.RAB.AttEstab.AMR]*
assignment {100.00}
setup per cell

VS.RAB.SuccEstab. numb Measuremen -


AMR er t of CS RAB
assignment
setup per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 830


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.AttEstab.A numb Measuremen -


MR er t of CS RAB
assignment
setup per cell

VS.RAB.SuccEstab % Measuremen [VS.RAB.SuccEstCS.Conv.


CS.Conv. t of CS RAB 64]/[VS.RAB.AttEstCS.Conv.
64.Cell.Rate assignment 64]*{100.00}
setup per cell

VS.RAB.SuccEstCS numb Measuremen -


.Conv.64 er t of CS RAB
assignment
setup per cell

VS.RAB.AttEstCS. numb Measuremen -


Conv.64 er t of CS RAB
assignment
setup per cell

VS.RAB.SuccEstab % Measuremen ([VS.RAB.SuccEstCS.Conv.


CS.Rate.Cell.AMR_ t of CS RAB 64]+
VP assignment [VS.RAB.SuccEstab.AMR])/
setup per cell ([VS.RAB.AttEstCS.Conv.64]
+[VS.RAB.AttEstab.AMR])

VS.RAB.SuccEstab. none Measuremen [VS.RAB.SuccEstCS.Conv.


AMR_VP t of CS RAB 64]+
assignment [VS.RAB.SuccEstab.AMR]
setup per cell

VS.RAB.AttEstab.A none Measuremen ([VS.RAB.AttEstCS.Conv.64]


MR_VP t of CS RAB +[VS.RAB.AttEstab.AMR])
assignment
setup per cell

VS.RAB.SuccEstab % Measuremen ([VS.RAB.SuccEstabPS.Conv


PS.Cell.Rate t of PS RAB ]+[VS.RAB.SuccEstabPS.Str]
assignment +[VS.RAB.SuccEstabPS.In-
setup per cell ter]+
[VS.RAB.SuccEstabPS.Bkg])/
([VS.RAB.AttEstabPS.Conv]
+[VS.RAB.AttEstabPS.Str]+
[VS.RAB.AttEstabPS.Inter]+
[VS.RAB.AttEstabPS.Bkg])*
{100.00}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 831


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.SuccEstPS. none Measuremen [VS.RAB.SuccEstabPS.Conv]


Cell t of PS RAB +[VS.RAB.SuccEstabPS.Str]+
assignment [VS.RAB.SuccEstabPS.Inter]
setup per cell +[VS.RAB.SuccEstabPS.Bkg]

VS.RAB.AttEstabPS numb Measuremen [VS.RAB.AttEstabPS.Conv]+


.Cell er t of PS RAB [VS.RAB.AttEstabPS.Str]+
assignment [VS.RAB.AttEstabPS.Inter]+
setup per cell [VS.RAB.AttEstabPS.Bkg]

VS.HSDPA.RAB.Su % HSDPA [VS.HSDPA.RAB.SuccEs-


ccEstab.Rate Measuremen tab]/[VS.HSDPA.RAB.AttEs-
t per cell tab]*{100.00}

VS.HSDPA.RAB.Su times HSDPA -


ccEstab Measuremen
t per cell

VS.HSDPA.RAB.At times HSDPA -


tEstab Measuremen
t per cell

RRC.Req.Call.Per.S % RRC ([VS.RRC.AttConnEstab.Cell]


ervice connection )/
setup (([VS.RAB.SuccEstabCS.Con
measurement v]+
per cell [VS.RAB.SuccEstabCS.Str])+
([VS.RAB.SuccEstabPS.Conv
]+[VS.RAB.SuccEstabPS.Str]
+[VS.RAB.SuccEstabPS.In-
ter]+
[VS.RAB.SuccEstabPS.Bkg]))

VS.RRC.AttConnEs times RRC -


tab.Cell connection
setup
measurement
per cell

VS.RAB.SuccEstab none Measuremen ([VS.RAB.SuccEstabCS.Conv


CSPS.Cell t of CS RAB ]+
assignment [VS.RAB.SuccEstabCS.Str])+
setup per cell ([VS.RAB.SuccEstabPS.Conv
]+[VS.RAB.SuccEstabPS.Str]
+[VS.RAB.SuccEstabPS.In-
ter]+
[VS.RAB.SuccEstabPS.Bkg])

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 832


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

CDR Radio.Call.Drop.Rat % Measuremen [VS.RAB.Loss.CS.RF.AMR]/


(cluster) e.AMR t of RAB [VS.RAB.SuccEstab.AMR]
release
triggered by
UTRAN per
cell

VS.RAB.Loss.CS.R numb Measuremen -


F.AMR er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.SuccEstab. numb Measuremen -


AMR er t of CS RAB
assignment
setup per cell

Radio.Call.Drop.Rat % Measuremen ([VS.RAB.Loss.CS.RF]-


e.VP t of RAB [VS.RAB.Loss.CS.RF.AMR])
release /[VS.RAB.SuccEstCS.Conv.
triggered by 64]
UTRAN per
cell

VS.RAB.Loss.RF.V none Measuremen [VS.RAB.Loss.CS.RF]-


P t of RAB [VS.RAB.Loss.CS.RF.AMR]
release
triggered by
UTRAN per
cell

VS.RAB.SuccEstCS numb Measuremen -


.Conv.64 er t of CS RAB
assignment
setup per cell

Radio.Call.Drop.Rat % Measuremen [VS.RAB.Loss.CS.RF]/


e.AMR_VP t of RAB ([VS.RAB.SuccEstCS.Conv.
release 64]+
triggered by [VS.RAB.SuccEstab.AMR])
UTRAN per
cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 833


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.Loss.CS.R numb Measuremen -


F er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.SuccEstab. none Measuremen [VS.RAB.SuccEstCS.Conv.


AMR_VP t of CS RAB 64]+
assignment [VS.RAB.SuccEstab.AMR]
setup per cell

VS.RAB.Loss.PS.R numb Measuremen -


F er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.SuccEstPS. none Measuremen [VS.RAB.SuccEstabPS.Conv]


Cell t of PS RAB +[VS.RAB.SuccEstabPS.Str]+
assignment [VS.RAB.SuccEstabPS.Inter]
setup per cell +[VS.RAB.SuccEstabPS.Bkg]

Radio.Call.Drop.Rat % HSDPA [VS.HSDPA.RAB.Loss.RF]/


e.PS.HSDPA Measuremen [VS.HSDPA.RAB.SuccEstab]
t per cell

VS.HSDPA.RAB.Lo times HSDPA -


ss.RF Measuremen
t per cell

VS.HSDPA.RAB.Su times HSDPA -


ccEstab Measuremen
t per cell

VS.CS.AMR.Call.D % Measuremen [VS.RAB.Loss.CS.AMR]/


rop.Cell.Rate t of RAB ([VS.RAB.Loss.CS.AMR]+
release [VS.RAB.Loss.CS.Norm.AM
triggered by R])*{100.00}
UTRAN per
cell

VS.CS.AMR.Call.D none Measuremen [VS.RAB.Loss.CS.AMR]


rop.Cell t of RAB
release
triggered by
UTRAN per
cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 834


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.CS.VP.Call.Dro % Measuremen [VS.RAB.Loss.CS.Conv64K]/


p.Cell.Rate t of RAB ([VS.RAB.Loss.CS.Conv64K]
release +[VS.Norm.Rel.CS.Conv.RB.
triggered by 64])*{100.00}
UTRAN per
cell

VS.RAB.Loss.CS.C numb Measuremen -


onv64K er t of RAB
release
triggered by
UTRAN per
cell

VS.CS.Call.Drop.Ra % Measuremen ([VS.RAB.Loss.CS.AMR]+


te.Cell.AMR_VP t of RAB [VS.RAB.Loss.CS.Conv64K])
release /([VS.RAB.SuccEstCS.Conv.
triggered by 64]+
UTRAN per [VS.RAB.SuccEstab.AMR])
cell

VS.CS.Call.Drop.Ce none Measuremen [VS.RAB.Loss.CS.AMR]+


ll.AMR_VP t of RAB [VS.RAB.Loss.CS.Conv64K]
release
triggered by
UTRAN per
cell

VS.PS.Call.Drop.Ce % Measuremen ([VS.RAB.Loss.PS.RF]+


ll.Rate t of RAB [VS.RAB.Loss.PS.Abnorm])/
release ([VS.RAB.Loss.PS.RF]+
triggered by [VS.RAB.Loss.PS.Abnorm]+
UTRAN per [VS.RAB.Loss.PS.Norm])*
cell {100.00}

VS.PS.Call.Drop.Ce numb Measuremen [VS.RAB.Loss.PS.RF]+


ll er t of RAB [VS.RAB.Loss.PS.Abnorm]
release
triggered by
UTRAN per
cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 835


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.HSDPA.RAB.A % HSDPA ([VS.HSDPA.RAB.Loss.Abn


bnormRel.Rate Measuremen orm.NonRF]+
t per cell [VS.HSDPA.RAB.Loss.RF])/
([VS.HSDPA.RAB.Loss.In-
Activity]+
[VS.HSDPA.RAB.Loss.Abno
rm.NonRF]+
[VS.HSDPA.RAB.Loss.RF]+
[VS.HSDPA.RAB.Loss.Norm
]+
[VS.HSDPA.ChR.HSDSCHto
DCH]+
[VS.HSDPA.ChR.HSDSCHto
FACH]+
[VS.HSDPA.HHO.H2D.Suc-
cOutIntraFreq]+
[VS.HSDPA.HHO.H2D.Suc-
cOutInterFreq])*{100.00}

VS.HSDPA.RAB.A none HSDPA [VS.HSDPA.RAB.Loss.Abno


bnormRel Measuremen rm.NonRF]+
t per cell [VS.HSDPA.RAB.Loss.RF]

HO Radio.Link.Add.Suc % Soft [SHO.SuccRLAddUESide]/


(cluster) c.Rate Handover [SHO.AttRLAddUESide]
Measuremen
t per cell

SHO.SuccRLAddU times Soft -


ESide Handover
Measuremen
t per cell

SHO.AttRLAddUE- times Soft -


Side Handover
Measuremen
t per cell

Radio.Link.Del.Succ % Soft [SHO.SuccRLDelUESide]/


.Rate Handover [SHO.AttRLDelUESide]
Measuremen
t per cell

SHO.SuccRLDelUE times Soft -


Side Handover
Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 836


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

SHO.AttRLDelUE- times Soft -


Side Handover
Measuremen
t per cell

VS.SHO.Success.Ce % Soft ([SHO.SuccRLAddUESide]+


ll.Rate Handover [SHO.SuccRLDelUESide])/
Measuremen ([SHO.AttRLAddUESide]+
t per cell [SHO.AttRLDelUESide])*
{100.00}

VS.SHO.SuccUESid none Soft [SHO.SuccRLAddUESide]+


e.Cell Handover [SHO.SuccRLDelUESide]
Measuremen
t per cell

VS.SHO.AttUESide. none Soft [SHO.AttRLAddUESide]+


Cell Handover [SHO.AttRLDelUESide]
Measuremen
t per cell

HO.3G_2G.CS.Rate % InterRAT [IRATHO.SuccOutCS]/


Handover [VS.RAB.SuccEstab.AMR]
Measuremen
t per cell

IRATHO.SuccOutC times InterRAT -


S Handover
Measuremen
t per cell

VS.RAB.SuccEstab. numb Measuremen -


AMR er t of CS RAB
assignment
setup per cell

VS.IRATHO.SuccO % InterRAT [IRATHO.SuccOutCS]/


utCS.Cell.Rate Handover [IRATHO.AttOutCS]*
Measuremen {100.00}
t per cell

IRATHO.AttOutCS times InterRAT -


Handover
Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 837


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.4.3 HO TopN Report

Report Type
Simple Report

NE Type
RNC

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

SHO VS.SHO.Fail.Cell none Soft [SHO.AttRLAddUESide]+


FAIL Handover [SHO.AttRLDelUESide]-
Measuremen [SHO.SuccRLAddUESide]-
t per cell [SHO.SuccRLDelUESide]

VS.SHO.AttUESide. none Soft [SHO.AttRLAddUESide]+


Cell Handover [SHO.AttRLDelUESide]
Measuremen
t per cell

SHO.FailRLAddUE times Soft -


Side.CfgUnsup Handover
Measuremen
t per cell

SHO.FailRLAddUE times Soft -


Side.Isr Handover
Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 838


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

SHO.FailRLAddUE times Soft -


Side.InvCfg Handover
Measuremen
t per cell

SHO.FailRLAddUE times Soft -


Side.NoReply Handover
Measuremen
t per cell

VS.SHO.Fail.Other. none Soft ([SHO.AttRLAddUESide]+


Cell Handover [SHO.AttRLDelUESide]-
Measuremen [SHO.SuccRLAddUESide]-
t per cell [SHO.SuccRLDelUESide])-
[SHO.FailRLAddUESide.Cfg
Unsup]-
[SHO.FailRLAddUESide.Isr]-
[SHO.FailRLAddUESide.Inv
Cfg]-
[SHO.FailRLAddUESide.No
Reply]

InterFRe VS.HHO.InterFreq.F none Hard [VS.HHO.InterFreq.AttOut]-


quest ailOut Handover [VS.HHO.InterFreq.SuccOut]
HHO Measuremen
Fail t per cell

VS.HHO.InterFreq. times Hard -


AttOut Handover
Measuremen
t per cell

VS.HHO.InterFreqO times Hard -


ut.CfgUnsupp Handover
Measuremen
t per cell

VS.HHO.InterFreqO times Hard -


ut.PyhChFail Handover
Measuremen
t per cell

VS.HHO.InterFreqO times Hard -


ut.FailUSR Handover
Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 839


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.HHO.InterFreqO times Hard -


ut.CellUpdt Handover
Measuremen
t per cell

VS.HHO.InterFreqO times Hard -


ut.CfgInvalid Handover
Measuremen
t per cell

VS.HHO.InterFreqO times Hard -


ut.NoReply Handover
Measuremen
t per cell

VS.HHO.InterFreqO times Hard -


ut.DLCodeRej Handover
Measuremen
t per cell

VS.HHO.InterFreqO times Hard -


ut.ULAdmsnDeny Handover
Measuremen
t per cell

VS.HHO.InterFreqO times Hard -


ut.DLAdmsnDeny Handover
Measuremen
t per cell

VS.HHO.InterFreq.F none Hard ([VS.HHO.InterFreq.AttOut]-


ailOther Handover [VS.HHO.InterFreq.Suc-
Measuremen cOut])-
t per cell [VS.HHO.InterFreqOut.CfgU
nsupp]-
[VS.HHO.InterFreqOut.PyhC
hFail]-
[VS.HHO.InterFreqOut.Fail-
USR]-
[VS.HHO.InterFreqOut.Cel-
lUpdt]-
[VS.HHO.InterFreqOut.CfgIn
valid]-
[VS.HHO.InterFreqOut.NoRe
ply]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 840


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

CS VS.IRATHO.Fail- none InterRAT [IRATHO.AttOutCS]-


InterRA OutCS Handover [IRATHO.SuccOutCS]
T HHO Measuremen
FAIL t per cell

IRATHO.AttOutCS times InterRAT -


Handover
Measuremen
t per cell

IRATHO.FailOutCS times InterRAT -


.CfgUnsupp Handover
Measuremen
t per cell

IRATHO.FailOutCS times InterRAT -


.PhyChFail Handover
Measuremen
t per cell

VS.IRATHO.FailOu none InterRAT ([IRATHO.AttOutCS]-


tCS.Other Handover [IRATHO.SuccOutCS])-
Measuremen [IRATHO.FailOutCS.CfgUn-
t per cell supp]-
[IRATHO.FailOutCS.PhyCh-
Fail]

PS VS.IRATHO.FailOu none InterRAT [IRATHO.AttOutPSUTRAN]-


InterRA tPSUTRAN.Cell Handover [IRATHO.SuccOutPSU-
T HHO Measuremen TRAN]
FAIL t per cell

IRATHO.AttOut- times InterRAT -


PSUTRAN Handover
Measuremen
t per cell

IRATHO.FailOutPS times InterRAT -


UTRAN.CfgUnsupp Handover
Measuremen
t per cell

IRATHO.FailOutPS times InterRAT -


UTRAN.PhyChFail Handover
Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 841


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.IRATHO.FailOu none InterRAT [IRATHO.AttOutPSUTRAN]-


tPSUTRAN.Other Handover [IRATHO.SuccOutPSU-
Measuremen TRAN]-
t per cell [IRATHO.FailOutPSUTRAN.
CfgUnsupp]-
[IRATHO.FailOutPSUTRAN.
PhyChFail]

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.4.4 Hot Traffic Cell TopN Report

Report Type
Simple Report

NE Type
RNC

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Hot VS.AMR.Ctrl.DL12. numb Measuremen -


Traffic 2 er t of RB
Cell Procedure
(AMR per cell
Ctrl
DL12.2)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 842


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RRC.SuccConn % RRC [RRC.SuccConnEstab.sum]/


Estab.Cell.Rate connection [VS.RRC.AttConnEstab.Cell]
setup *{100.00}
measurement
per cell

VS.HHO.InterFreq. % Hard [VS.HHO.InterFreq.SuccOut]/


Out.Cell.Rate Handover [VS.HHO.InterFreq.AttOut]*
Measuremen {100.00}
t per cell

VS.MeanTCP dBm Cell TX and -


RX Power
Measuremen
t per cell

VS.MAC.SRNCIub byte Traffic -


BytesPSInt.Tx Measuremen
t per cell

VS.MAC.SRNCIub byte Traffic -


BytesPSBkg.Tx Measuremen
t per cell

VS.MaxRTWP dBm Cell TX and -


RX Power
Measuremen
t per cell

VS.MinRTWP dBm Cell TX and -


RX Power
Measuremen
t per cell

VS.MaxTCP dBm Cell TX and -


RX Power
Measuremen
t per cell

VS.RB.DLConvCS. numb Measuremen -


64 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


64 er t of RB
Procedure
per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 843


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RB.DLInterPS. numb Measuremen -


128 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


144 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


384 er t of RB
Procedure
per cell

VS.RAB.SuccEstab % Measuremen [VS.RAB.SuccEstab.AMR]/


CS.AMR.Cell.Rate t of CS RAB [VS.RAB.AttEstab.AMR]*
assignment {100.00}
setup per cell

VS.RAB.SuccEstab % Measuremen [VS.RAB.SuccEstCS.Conv.


CS.Conv. t of CS RAB 64]/[VS.RAB.AttEstCS.Conv.
64.Cell.Rate assignment 64]*{100.00}
setup per cell

VS.RAB.SuccEstab % Measuremen ([VS.RAB.SuccEstabPS.Conv


PS.Cell.Rate t of PS RAB ]+[VS.RAB.SuccEstabPS.Str]
assignment +[VS.RAB.SuccEstabPS.In-
setup per cell ter]+
[VS.RAB.SuccEstabPS.Bkg])/
([VS.RAB.AttEstabPS.Conv]
+[VS.RAB.AttEstabPS.Str]+
[VS.RAB.AttEstabPS.Inter]+
[VS.RAB.AttEstabPS.Bkg])*
{100.00}

VS.SuccRBSetup.Ce % Measuremen [VS.SuccRBSetup]/


ll.Rate t of RB [VS.AttRBSetup]*{100.00}
Procedure
per cell

VS.IRATHO.SuccO % InterRAT [IRATHO.SuccOutCS]/


utCS.Cell.Rate Handover [IRATHO.AttOutCS]*
Measuremen {100.00}
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 844


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.IRATHO.PS64.S % InterRAT [VS.IRATHO.PS64.SuccRe-


uccRelocOut.Cell.R Handover locOut]/
ate Measuremen [VS.IRATHO.PS64.ReqRe-
t per cell locOut]

VS.IRATHO.PS128. % InterRAT [VS.IRATHO.PS128.SuccRe-


SuccRelocOut.Cell. Handover locOut]/
Rate Measuremen [VS.IRATHO.PS128.ReqRe-
t per cell locOut]

VS.IRATHO.PS384. % InterRAT [VS.IRATHO.PS384.SuccRe-


SuccRelocOut.Cell. Handover locOut]/
Rate Measuremen [VS.IRATHO.PS384.ReqRe-
t per cell locOut]

VS.CS.AMR.Call.D % Measuremen [VS.RAB.Loss.CS.AMR]/


rop.Cell.Rate t of RAB ([VS.RAB.Loss.CS.AMR]+
release [VS.RAB.Loss.CS.Norm.AM
triggered by R])*{100.00}
UTRAN per
cell

VS.CS.VP.Call.Dro % Measuremen [VS.RAB.Loss.CS.Conv64K]/


p.Cell.Rate t of RAB ([VS.RAB.Loss.CS.Conv64K]
release +[VS.Norm.Rel.CS.Conv.RB.
triggered by 64])*{100.00}
UTRAN per
cell

VS.PS.Call.Drop.Ce % Measuremen ([VS.RAB.Loss.PS.RF]+


ll.Rate t of RAB [VS.RAB.Loss.PS.Abnorm])/
release ([VS.RAB.Loss.PS.RF]+
triggered by [VS.RAB.Loss.PS.Abnorm]+
UTRAN per [VS.RAB.Loss.PS.Norm])*
cell {100.00}

VS.PCH.Utilization. % Traffic [VS.MAC.CRNCIubBytesPC


Cell.Rate Measuremen H.Tx]/
t per cell ([VS.CRNC.IUB.PCH.Band-
width]*{GP}*{60})*{100.00}

VS.FACH.Utilizatio % Traffic [VS.MAC.CRNCIubBytesFA


n.Cell.Rate Measuremen CH.Tx]/
t per cell ([VS.CRNC.IUB.FACH.Band
width]*{GP}*{60})*{100.00}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 845


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RACH.Utilizatio % Traffic [VS.MAC.CRNCIubBytesRA


n.Cell.Rate Measuremen CH.Rx]/
t per cell ([VS.CRNC.IUB.RACH.Band
width]*{GP}*{60})*{100.00}

Hot VS.RB.DLInterPS. numb Measuremen -


Traffic 384 er t of RB
Cell(RB Procedure
DLInterP per cell
S 384)
VS.RRC.SuccConn % RRC [RRC.SuccConnEstab.sum]/
Estab.Cell.Rate connection [VS.RRC.AttConnEstab.Cell]
setup *{100.00}
measurement
per cell

VS.HHO.InterFreq. % Hard [VS.HHO.InterFreq.SuccOut]/


Out.Cell.Rate Handover [VS.HHO.InterFreq.AttOut]*
Measuremen {100.00}
t per cell

VS.MeanTCP dBm Cell TX and -


RX Power
Measuremen
t per cell

VS.MAC.SRNCIub byte Traffic -


BytesPSInt.Tx Measuremen
t per cell

VS.MAC.SRNCIub byte Traffic -


BytesPSBkg.Tx Measuremen
t per cell

VS.MaxRTWP dBm Cell TX and -


RX Power
Measuremen
t per cell

VS.MinRTWP dBm Cell TX and -


RX Power
Measuremen
t per cell

VS.MaxTCP dBm Cell TX and -


RX Power
Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 846


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.AMR.Ctrl.DL12. numb Measuremen -


2 er t of RB
Procedure
per cell

VS.RB.DLConvCS. numb Measuremen -


64 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


64 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


128 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


144 er t of RB
Procedure
per cell

VS.RAB.SuccEstab % Measuremen [VS.RAB.SuccEstab.AMR]/


CS.AMR.Cell.Rate t of CS RAB [VS.RAB.AttEstab.AMR]*
assignment {100.00}
setup per cell

VS.RAB.SuccEstab % Measuremen [VS.RAB.SuccEstCS.Conv.


CS.Conv. t of CS RAB 64]/[VS.RAB.AttEstCS.Conv.
64.Cell.Rate assignment 64]*{100.00}
setup per cell

VS.RAB.SuccEstab % Measuremen ([VS.RAB.SuccEstabPS.Conv


PS.Cell.Rate t of PS RAB ]+[VS.RAB.SuccEstabPS.Str]
assignment +[VS.RAB.SuccEstabPS.In-
setup per cell ter]+
[VS.RAB.SuccEstabPS.Bkg])/
([VS.RAB.AttEstabPS.Conv]
+[VS.RAB.AttEstabPS.Str]+
[VS.RAB.AttEstabPS.Inter]+
[VS.RAB.AttEstabPS.Bkg])*
{100.00}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 847


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.SuccRBSetup.Ce % Measuremen [VS.SuccRBSetup]/


ll.Rate t of RB [VS.AttRBSetup]*{100.00}
Procedure
per cell

VS.IRATHO.SuccO % InterRAT [IRATHO.SuccOutCS]/


utCS.Cell.Rate Handover [IRATHO.AttOutCS]*
Measuremen {100.00}
t per cell

VS.IRATHO.PS64.S % InterRAT [VS.IRATHO.PS64.SuccRe-


uccRelocOut.Cell.R Handover locOut]/
ate Measuremen [VS.IRATHO.PS64.ReqRe-
t per cell locOut]

VS.IRATHO.PS128. % InterRAT [VS.IRATHO.PS128.SuccRe-


SuccRelocOut.Cell. Handover locOut]/
Rate Measuremen [VS.IRATHO.PS128.ReqRe-
t per cell locOut]

VS.IRATHO.PS384. % InterRAT [VS.IRATHO.PS384.SuccRe-


SuccRelocOut.Cell. Handover locOut]/
Rate Measuremen [VS.IRATHO.PS384.ReqRe-
t per cell locOut]

VS.CS.AMR.Call.D % Measuremen [VS.RAB.Loss.CS.AMR]/


rop.Cell.Rate t of RAB ([VS.RAB.Loss.CS.AMR]+
release [VS.RAB.Loss.CS.Norm.AM
triggered by R])*{100.00}
UTRAN per
cell

VS.CS.VP.Call.Dro % Measuremen [VS.RAB.Loss.CS.Conv64K]/


p.Cell.Rate t of RAB ([VS.RAB.Loss.CS.Conv64K]
release +[VS.Norm.Rel.CS.Conv.RB.
triggered by 64])*{100.00}
UTRAN per
cell

VS.PS.Call.Drop.Ce % Measuremen ([VS.RAB.Loss.PS.RF]+


ll.Rate t of RAB [VS.RAB.Loss.PS.Abnorm])/
release ([VS.RAB.Loss.PS.RF]+
triggered by [VS.RAB.Loss.PS.Abnorm]+
UTRAN per [VS.RAB.Loss.PS.Norm])*
cell {100.00}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 848


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.PCH.Utilization. % Traffic [VS.MAC.CRNCIubBytesPC


Cell.Rate Measuremen H.Tx]/
t per cell ([VS.CRNC.IUB.PCH.Band-
width]*{GP}*{60})*{100.00}

VS.FACH.Utilizatio % Traffic [VS.MAC.CRNCIubBytesFA


n.Cell.Rate Measuremen CH.Tx]/
t per cell ([VS.CRNC.IUB.FACH.Band
width]*{GP}*{60})*{100.00}

VS.RACH.Utilizatio % Traffic [VS.MAC.CRNCIubBytesRA


n.Cell.Rate Measuremen CH.Rx]/
t per cell ([VS.CRNC.IUB.RACH.Band
width]*{GP}*{60})*{100.00}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.4.5 HSDPA TopN Report

Report Type
Simple Report

NE Type
RNC

Object Type
UCell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 849


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

HSDPA VS.HSDPA.RAB.Fa none HSDPA [VS.HSDPA.RAB.AttEstab]-


RAB Fail ilEstab Measuremen [VS.HSDPA.RAB.SuccEstab]
t per cell

VS.HSDPA.RAB.At times HSDPA -


tEstab Measuremen
t per cell

HSDPA VS.HSDPA.RAB.A none HSDPA [VS.HSDPA.RAB.Loss.Abno


RAB bnormRel Measuremen rm.NonRF]+
Abnorm t per cell [VS.HSDPA.RAB.Loss.RF]
Rel
VS.HSDPA.RAB.Re none HSDPA [VS.HSDPA.RAB.Loss.InAc-
l Measuremen tivity]+
t per cell [VS.HSDPA.RAB.Loss.Abno
rm.NonRF]+
[VS.HSDPA.RAB.Loss.RF]+
[VS.HSDPA.RAB.Loss.Norm
]+
[VS.HSDPA.ChR.HSDSCHto
DCH]+
[VS.HSDPA.ChR.HSDSCHto
FACH]+
[VS.HSDPA.HHO.H2D.Suc-
cOutIntraFreq]+
[VS.HSDPA.HHO.H2D.Suc-
cOutInterFreq]

VS.HSDPA.MeanC none HSDPA ({8}*


hThroughput.NEW Measuremen [VS.HSDPA.MeanChThrough
t per cell put.TotalBytes]/
([VS.HSDPA.MeanChThroug
hput.Times]))

VS.HSDPA.MeanC byte HSDPA -


hThroughput.Total- Measuremen
Bytes t per cell

VS.HSDPA.UE.Mea numb HSDPA -


n.Cell er Measuremen
t per cell

VS.HSDPA.MACD. numb HSDPA -


Mean.Cell er Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 850


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

HSDPA VS.HSDPA.ServCel none HSDPA [VS.HSDPA.HHO.AttOutIn-


HHO lChg.HHO.IntraFreq Measuremen traFreq]-
IntraFRe .NoChR.Fail t per cell [VS.HSDPA.HHO.SuccOu-
quest Fail tIntraFreq]

VS.HSDPA.HHO.At times HSDPA -


tOutIntraFreq Measuremen
t per cell

HSDPA VS.HSDPA.ServCel none HSDPA [VS.HSDPA.HHO.AttOutIn-


HHO lChg.HHO.InterFreq Measuremen terFreq]-
InterFRe .NoChR.Fail t per cell [VS.HSDPA.HHO.SuccOu-
quest Fail tInterFreq]

VS.HSDPA.HHO.At times HSDPA -


tOutInterFreq Measuremen
t per cell

HSDPA VS.HSDPA.ChR.HS none HSDPA [VS.HSDPA.ChR.HSDSCHto


HSDSC DSCHtoDCH.Fail Measuremen DCH.Att]-
HtoDCH t per cell [VS.HSDPA.ChR.HSDSCHto
Fail DCH]

VS.HSDPA.ChR.HS times HSDPA -


DSCHtoDCH.Att Measuremen
t per cell

HSDPA VS.HSDPA.ChR.D none HSDPA [VS.HSDPA.ChR.DCHtoHSD


DCHtoH CHtoHSDSCH.Fail Measuremen SCH.Att]-
SDSCH t per cell [VS.HSDPA.ChR.DCHtoHSD
Fail SCH]

VS.HSDPA.ChR.D times HSDPA -


CHtoHSDSCH.Att Measuremen
t per cell

HSDPA VS.HSDPA.ServCel none HSDPA [VS.HSDPA.SHO.CellChg.At


ServCell lChg.SHO.Fail Measuremen tOut]-
Chg Fail t per cell [VS.HSDPA.SHO.CellChg.Su
ccOut]

VS.HSDPA.SHO.Ce times HSDPA -


llChg.AttOut Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 851


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.4.6 Iur Performance TopN Report

Report Type
Simple Report

NE Type
RNC

Object Type
IUR Interface

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Iur VS.Iur.SHO.Att times Measuremen -


Performa t related to
nce SRNC in Iur
interface

VS.Iur.SHO.Succ times Measuremen -


t related to
SRNC in Iur
interface

VS.IUR.SHO.Succ. % Measuremen [VS.Iur.SHO.Succ]/


Rate t related to [VS.Iur.SHO.Att]*{100.00}
SRNC in Iur
interface

VS.SHO.SuccRLSet times Measuremen -


upIur.Rx t related to
SRNC in Iur
interface

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 852


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.SHO.AttRLSetu times Measuremen -


pIur.Tx t related to
SRNC in Iur
interface

VS.IUR.RL.Setup.S % Measuremen [VS.SHO.SuccRLSetupIur.Rx


ucc.Rate t related to ]/
SRNC in Iur [VS.SHO.AttRLSetupIur.Tx]*
interface {100.00}

VS.SHO.SuccRLAd times Measuremen -


dIur.Rx t related to
SRNC in Iur
interface

VS.SHO.AttRLAddI times Measuremen -


ur.Tx t related to
SRNC in Iur
interface

VS.IUR.RL.Additio % Measuremen [VS.SHO.SuccRLAddIur.Rx]/


n.Succ.Rate t related to [VS.SHO.AttRLAddIur.Tx]*
SRNC in Iur {100.00}
interface

VS.SHO.SuccRLRe numb Measuremen -


cfgIur.Rx er t related to
SRNC in Iur
interface

VS.SHO.AttRLRecf numb Measuremen -


gIur.Tx er t related to
SRNC in Iur
interface

VS.IUR.RL.RECFG % Measuremen [VS.SHO.SuccRLRecfgIur.Rx


.Succe.Rate t related to ]/
SRNC in Iur [VS.SHO.AttRLRecfgIur.Tx]
interface *{100.00}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 853


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.4.7 KPI Report

Report Type
Simple Report

NE Type
RNC

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Traffic VS.AMR.Ctrl.DL12. numb Measuremen -


2 er t of RB
Procedure
per cell

VS.RB.DLConvCS. numb Measuremen -


64 er t of RB
Procedure
per cell

PS.Inter.KByte.DL. none Measuremen ([VS.PS.Int.DL.8.Thruput]/


Throughput t related to ({1024}*{8}))+
throughput ([VS.PS.Int.DL.64.Thruput]/
per cell ({1024}*{8}))+
([VS.PS.Int.DL.128.Thruput]/
({1024}*{8}))+
([VS.PS.Int.DL.384.Thruput]/
({1024}*{8}))

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 854


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

PS.Bkg.KByte.DL.T none Measuremen ([VS.PS.Bkg.DL.8.Thruput]/


hroughput t related to ({1024}*{8}))+
throughput ([VS.PS.Bkg.DL.64.Thruput]/
per cell ({1024}*{8}))+
([VS.PS.Bkg.DL.
128.Thruput]/({1024}*{8}))+
([VS.PS.Bkg.DL.
384.Thruput]/({1024}*{8}))

VS.HSDPA.MeanC none HSDPA [VS.HSDPA.MeanChThrough


hThroughput.Total- Measuremen put.TotalBytes]/({1024}*
MBytes t per cell {1024})

VS.AMR.Call.Dura- none Measuremen ([VS.AMR.Ctrl.DL12.2]*


tion t of RB {60}*{60})/
Procedure [VS.RAB.SuccEstab.AMR]
per cell

Through VS.HSDPA.Kbps.M none HSDPA {8}*


put eanChThroughput Measuremen [VS.HSDPA.MeanChThrough
t per cell put.TotalBytes]/({GP}*{60}*
{1024})

VS.PS.Throughput. none Measuremen ([VS.PS.Bkg.DL.64.Thruput]/


DL64.bps t related to [VS.PS.Bkg.DL.64.Times])+
throughput ([VS.PS.Int.DL.64.Thruput]/
per cell [VS.PS.Int.DL.64.Times])

VS.PS.Throughput. none Measuremen ([VS.PS.Bkg.DL.


DL128.bps t related to 128.Thruput]/[VS.PS.Bkg.DL.
throughput 128.Times])+([VS.PS.Int.DL.
per cell 128.Thruput]/[VS.PS.Int.DL.
128.Times])

VS.PS.Throughput. none Measuremen ([VS.PS.Bkg.DL.


DL384.bps t related to 384.Thruput]/[VS.PS.Bkg.DL.
throughput 384.Times])+([VS.PS.Int.DL.
per cell 384.Thruput]/[VS.PS.Int.DL.
384.Times])

VS.PS.Throughput. none Measuremen ([VS.PS.Bkg.UL.64.Thruput]/


UL64.bps t related to [VS.PS.Bkg.UL.64.Times])+
throughput ([VS.PS.Int.UL.64.Thruput]/
per cell [VS.PS.Int.UL.64.Times])

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 855


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.PS.Throughput. none Measuremen ([VS.PS.Bkg.UL.


UL128.bps t related to 128.Thruput]/[VS.PS.Bkg.UL.
throughput 128.Times])+([VS.PS.Int.UL.
per cell 128.Thruput]/[VS.PS.Int.UL.
128.Times])

VS.PS.Throughput. none Measuremen ([VS.PS.Bkg.UL.


UL384.bps t related to 384.Thruput]/[VS.PS.Bkg.UL.
throughput 384.Times])+([VS.PS.Int.UL.
per cell 384.Thruput]/[VS.PS.Int.UL.
384.Times])

Access Call.Setup.Success. % RRC (([RRC.SuccConnEstab.sum])


Rate.AMR connection /
setup ([VS.RRC.AttConnEstab.Cell]
measurement ))*
per cell ([VS.RAB.SuccEstab.AMR]/
[VS.RAB.AttEstab.AMR])

Call.Setup.Success. % RRC (([RRC.SuccConnEstab.sum])


Rate.VP connection /
setup ([VS.RRC.AttConnEstab.Cell]
measurement ))*
per cell ([VS.RAB.SuccEstCS.Conv.
64]/[VS.RAB.AttEstCS.Conv.
64])

Call.Setup.Success. % RRC (([RRC.SuccConnEstab.sum])


Rate.AMR_VP connection /
setup ([VS.RRC.AttConnEstab.Cell]
measurement ))*
per cell (([VS.RAB.SuccEstab.AMR]
+[VS.RAB.SuccEstCS.Conv.
64])/
([VS.RAB.AttEstab.AMR]+
[VS.RAB.AttEstCS.Conv.
64]))

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 856


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Call.Setup.Success. % RRC (([RRC.SuccConnEstab.sum])


Rate.PS connection /
setup ([VS.RRC.AttConnEstab.Cell]
measurement ))*
per cell (([VS.RAB.SuccEstabPS.Con
v]+
[VS.RAB.SuccEstabPS.Str]+
[VS.RAB.SuccEstabPS.Inter]
+
[VS.RAB.SuccEstabPS.Bkg])/
([VS.RAB.AttEstabPS.Conv]
+[VS.RAB.AttEstabPS.Str]+
[VS.RAB.AttEstabPS.Inter]+
[VS.RAB.AttEstabPS.Bkg]))

RRC.Setup.Success. % RRC ([RRC.SuccConnEstab.Og-


Rate.Conv connection ConvCall]+
setup [RRC.SuccConnEstab.TmCon
measurement vCall])/
per cell ([RRC.AttConnEstab.TmCon
vCall]+
[RRC.AttConnEstab.Org-
ConvCall])

RRC.Setup.Success. none RRC [RRC.SuccConnEstab.Og-


Conv connection ConvCall]+
setup [RRC.SuccConnEstab.TmCon
measurement vCall]
per cell

RRC.Setup.Attempt. none RRC [RRC.AttConnEstab.TmConv


Conv connection Call]+
setup [RRC.AttConnEstab.Org-
measurement ConvCall]
per cell

RRC.Setup.Success. % RRC ([RRC.SuccConnEstab.OrgStr


Rate.Str connection Call]+
setup [RRC.SuccConnEstab.TmStr
measurement Call])/
per cell ([RRC.AttConnEstab.TmStrC
all]+
[RRC.AttConnEstab.OrgStr-
Call])

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 857


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

RRC.Setup.Success. none RRC [RRC.SuccConnEstab.OrgStr-


Str connection Call]+
setup [RRC.SuccConnEstab.TmStr
measurement Call]
per cell

RRC.Setup.Attempt. none RRC [RRC.AttConnEstab.TmStrCa


Str connection ll]+
setup [RRC.AttConnEstab.OrgStr-
measurement Call]
per cell

RRC.Setup.Success. % RRC ([RRC.SuccConnEstab.OrgItr-


Rate.BESer connection Call]+
setup [RRC.SuccConnEstab.OrgBk
measurement gCall]+
per cell [RRC.SuccConnEstab.TmItr-
Call]+
[RRC.SuccConnEstab.TmBkg
Call]+
[RRC.SuccConnEstab.OgHhP
rSig]+
[RRC.SuccConnEstab.TmHhP
rSig])/
([RRC.AttConnEstab.TmIn-
terCall]+
[RRC.AttConnEstab.TmBkgC
all]+[RRC.AttConnEstab.Or-
gInterCall]+
[RRC.AttConnEstab.OrgBkg-
Call]+
[RRC.AttConnEstab.OgHhPr-
Sig]+
[RRC.AttConnEstab.TmHhPr
Sig])

RRC.Setup.Success. none RRC [RRC.SuccConnEstab.OrgItr-


BESer connection Call]+
setup [RRC.SuccConnEstab.OrgBk
measurement gCall]+
per cell [RRC.SuccConnEstab.TmItr-
Call]+
[RRC.SuccConnEstab.TmBkg
Call]+
[RRC.SuccConnEstab.OgHhP
rSig]+
[RRC.SuccConnEstab.TmHhP
rSig]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 858


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

RRC.Setup.Attempt. none RRC [RRC.AttConnEstab.TmInter-


BESer connection Call]+
setup [RRC.AttConnEstab.TmBkgC
measurement all]+[RRC.AttConnEstab.Or-
per cell gInterCall]+
[RRC.AttConnEstab.OrgBkg-
Call]+
[RRC.AttConnEstab.OgHhPr-
Sig]+
[RRC.AttConnEstab.TmHhPr
Sig]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 859


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RRC.SuccConn % RRC ([RRC.SuccConnEstab.Emg-


Estab.Other_ORO.R connection Call]+
ate.Cell setup [RRC.SuccConnEstab.IRAT-
measurement CelRes]+
per cell [RRC.SuccConnEstab.IRATC
CO]+
[RRC.SuccConnEstab.Reg]+
[RRC.SuccConnEstab.Detach]
+[RRC.SuccConnEstab.Un-
kown]+
[RRC.SuccConnEstab.Org-
SubCall]+
[RRC.SuccConnEstab.OgLwP
rSig]+
[RRC.SuccConnEstab.TmLw
PrSig]+
[RRC.SuccConnEstab.CallRe-
Est])/
([RRC.AttConnEstab.Emg-
Call]+
[RRC.AttConnEstab.IRAT-
CelRes]+
[RRC.AttConnEstab.IRATC-
CO]+
[RRC.AttConnEstab.Reg]+
[RRC.AttConnEstab.Detach]+
[RRC.AttConnEstab.Un-
known]+
[RRC.AttConnEstab.OgSub-
Call]+
[RRC.AttConnEstab.OgLwPr-
Sig]+
[RRC.AttConnEstab.TmLwPr
Sig]+
[RRC.AttConnEstab.CallRe-
Est])

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 860


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

RRC.SuccConnEsta none RRC [RRC.SuccConnEstab.Emg-


b.Other_ORO.Cell connection Call]+
setup [RRC.SuccConnEstab.IRAT-
measurement CelRes]+
per cell [RRC.SuccConnEstab.IRATC
CO]+
[RRC.SuccConnEstab.Reg]+
[RRC.SuccConnEstab.Detach]
+[RRC.SuccConnEstab.Un-
kown]+
[RRC.SuccConnEstab.Org-
SubCall]+
[RRC.SuccConnEstab.OgLwP
rSig]+
[RRC.SuccConnEstab.TmLw
PrSig]+
[RRC.SuccConnEstab.CallRe-
Est]

RRC.AttConnEstab. none RRC [RRC.AttConnEstab.Emg-


Other_ORO.Cell connection Call]+
setup [RRC.AttConnEstab.IRAT-
measurement CelRes]+
per cell [RRC.AttConnEstab.IRATC-
CO]+
[RRC.AttConnEstab.Reg]+
[RRC.AttConnEstab.Detach]+
[RRC.AttConnEstab.Un-
known]+
[RRC.AttConnEstab.OgSub-
Call]+
[RRC.AttConnEstab.OgLwPr-
Sig]+
[RRC.AttConnEstab.TmLwPr
Sig]+
[RRC.AttConnEstab.CallRe-
Est]

VS.RAB.SuccEstab % Measuremen [VS.RAB.SuccEstab.AMR]/


CS.AMR.Cell.Rate t of CS RAB [VS.RAB.AttEstab.AMR]*
assignment {100.00}
setup per cell

VS.RAB.SuccEstab. numb Measuremen -


AMR er t of CS RAB
assignment
setup per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 861


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.AttEstab.A numb Measuremen -


MR er t of CS RAB
assignment
setup per cell

VS.RAB.SuccEstab % Measuremen [VS.RAB.SuccEstCS.Conv.


CS.Conv. t of CS RAB 64]/[VS.RAB.AttEstCS.Conv.
64.Cell.Rate assignment 64]*{100.00}
setup per cell

VS.RAB.SuccEstCS numb Measuremen -


.Conv.64 er t of CS RAB
assignment
setup per cell

VS.RAB.AttEstCS. numb Measuremen -


Conv.64 er t of CS RAB
assignment
setup per cell

VS.RAB.SuccEstab % Measuremen ([VS.RAB.SuccEstCS.Conv.


CS.Rate.Cell.AMR_ t of CS RAB 64]+
VP assignment [VS.RAB.SuccEstab.AMR])/
setup per cell ([VS.RAB.AttEstCS.Conv.64]
+[VS.RAB.AttEstab.AMR])

VS.RAB.SuccEstab. none Measuremen [VS.RAB.SuccEstCS.Conv.


AMR_VP t of CS RAB 64]+
assignment [VS.RAB.SuccEstab.AMR]
setup per cell

VS.RAB.AttEstab.A none Measuremen ([VS.RAB.AttEstCS.Conv.64]


MR_VP t of CS RAB +[VS.RAB.AttEstab.AMR])
assignment
setup per cell

VS.RAB.SuccEstab % Measuremen ([VS.RAB.SuccEstabPS.Conv


PS.Cell.Rate t of PS RAB ]+[VS.RAB.SuccEstabPS.Str]
assignment +[VS.RAB.SuccEstabPS.In-
setup per cell ter]+
[VS.RAB.SuccEstabPS.Bkg])/
([VS.RAB.AttEstabPS.Conv]
+[VS.RAB.AttEstabPS.Str]+
[VS.RAB.AttEstabPS.Inter]+
[VS.RAB.AttEstabPS.Bkg])*
{100.00}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 862


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.SuccEstPS. none Measuremen [VS.RAB.SuccEstabPS.Conv]


Cell t of PS RAB +[VS.RAB.SuccEstabPS.Str]+
assignment [VS.RAB.SuccEstabPS.Inter]
setup per cell +[VS.RAB.SuccEstabPS.Bkg]

VS.RAB.AttEstabPS numb Measuremen [VS.RAB.AttEstabPS.Conv]+


.Cell er t of PS RAB [VS.RAB.AttEstabPS.Str]+
assignment [VS.RAB.AttEstabPS.Inter]+
setup per cell [VS.RAB.AttEstabPS.Bkg]

VS.HSDPA.RAB.Su % HSDPA [VS.HSDPA.RAB.SuccEs-


ccEstab.Rate Measuremen tab]/[VS.HSDPA.RAB.AttEs-
t per cell tab]*{100.00}

VS.HSDPA.RAB.Su times HSDPA -


ccEstab Measuremen
t per cell

VS.HSDPA.RAB.At times HSDPA -


tEstab Measuremen
t per cell

RRC.Req.Call.Per.S % RRC ([VS.RRC.AttConnEstab.Cell]


ervice connection )/
setup (([VS.RAB.SuccEstabCS.Con
measurement v]+
per cell [VS.RAB.SuccEstabCS.Str])+
([VS.RAB.SuccEstabPS.Conv
]+[VS.RAB.SuccEstabPS.Str]
+[VS.RAB.SuccEstabPS.In-
ter]+
[VS.RAB.SuccEstabPS.Bkg]))

VS.RRC.AttConnEs times RRC -


tab.Cell connection
setup
measurement
per cell

VS.RAB.SuccEstab none Measuremen ([VS.RAB.SuccEstabCS.Conv


CSPS.Cell t of CS RAB ]+
assignment [VS.RAB.SuccEstabCS.Str])+
setup per cell ([VS.RAB.SuccEstabPS.Conv
]+[VS.RAB.SuccEstabPS.Str]
+[VS.RAB.SuccEstabPS.In-
ter]+
[VS.RAB.SuccEstabPS.Bkg])

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 863


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

CDR Radio.Call.Drop.Rat % Measuremen [VS.RAB.Loss.CS.RF.AMR]/


e.AMR t of RAB [VS.RAB.SuccEstab.AMR]
release
triggered by
UTRAN per
cell

VS.RAB.Loss.CS.R numb Measuremen -


F.AMR er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.SuccEstab. numb Measuremen -


AMR er t of CS RAB
assignment
setup per cell

Radio.Call.Drop.Rat % Measuremen ([VS.RAB.Loss.CS.RF]-


e.VP t of RAB [VS.RAB.Loss.CS.RF.AMR])
release /[VS.RAB.SuccEstCS.Conv.
triggered by 64]
UTRAN per
cell

VS.RAB.Loss.RF.V none Measuremen [VS.RAB.Loss.CS.RF]-


P t of RAB [VS.RAB.Loss.CS.RF.AMR]
release
triggered by
UTRAN per
cell

VS.RAB.SuccEstCS numb Measuremen -


.Conv.64 er t of CS RAB
assignment
setup per cell

Radio.Call.Drop.Rat % Measuremen [VS.RAB.Loss.CS.RF]/


e.AMR_VP t of RAB ([VS.RAB.SuccEstCS.Conv.
release 64]+
triggered by [VS.RAB.SuccEstab.AMR])
UTRAN per
cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 864


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.Loss.CS.R numb Measuremen -


F er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.SuccEstab. none Measuremen [VS.RAB.SuccEstCS.Conv.


AMR_VP t of CS RAB 64]+
assignment [VS.RAB.SuccEstab.AMR]
setup per cell

VS.RAB.Loss.PS.R numb Measuremen -


F er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.SuccEstPS. none Measuremen [VS.RAB.SuccEstabPS.Conv]


Cell t of PS RAB +[VS.RAB.SuccEstabPS.Str]+
assignment [VS.RAB.SuccEstabPS.Inter]
setup per cell +[VS.RAB.SuccEstabPS.Bkg]

Radio.Call.Drop.Rat % HSDPA [VS.HSDPA.RAB.Loss.RF]/


e.PS.HSDPA Measuremen [VS.HSDPA.RAB.SuccEstab]
t per cell

VS.HSDPA.RAB.Lo times HSDPA -


ss.RF Measuremen
t per cell

VS.HSDPA.RAB.Su times HSDPA -


ccEstab Measuremen
t per cell

VS.CS.AMR.Call.D % Measuremen [VS.RAB.Loss.CS.AMR]/


rop.Cell.Rate t of RAB ([VS.RAB.Loss.CS.AMR]+
release [VS.RAB.Loss.CS.Norm.AM
triggered by R])*{100.00}
UTRAN per
cell

VS.CS.AMR.Call.D none Measuremen [VS.RAB.Loss.CS.AMR]


rop.Cell t of RAB
release
triggered by
UTRAN per
cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 865


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.CS.VP.Call.Dro % Measuremen [VS.RAB.Loss.CS.Conv64K]/


p.Cell.Rate t of RAB ([VS.RAB.Loss.CS.Conv64K]
release +[VS.Norm.Rel.CS.Conv.RB.
triggered by 64])*{100.00}
UTRAN per
cell

VS.RAB.Loss.CS.C numb Measuremen -


onv64K er t of RAB
release
triggered by
UTRAN per
cell

VS.CS.Call.Drop.Ra % Measuremen ([VS.RAB.Loss.CS.AMR]+


te.Cell.AMR_VP t of RAB [VS.RAB.Loss.CS.Conv64K])
release /([VS.RAB.SuccEstCS.Conv.
triggered by 64]+
UTRAN per [VS.RAB.SuccEstab.AMR])
cell

VS.CS.Call.Drop.Ce none Measuremen [VS.RAB.Loss.CS.AMR]+


ll.AMR_VP t of RAB [VS.RAB.Loss.CS.Conv64K]
release
triggered by
UTRAN per
cell

VS.PS.Call.Drop.Ce % Measuremen ([VS.RAB.Loss.PS.RF]+


ll.Rate t of RAB [VS.RAB.Loss.PS.Abnorm])/
release ([VS.RAB.Loss.PS.RF]+
triggered by [VS.RAB.Loss.PS.Abnorm]+
UTRAN per [VS.RAB.Loss.PS.Norm])*
cell {100.00}

VS.PS.Call.Drop.Ce numb Measuremen [VS.RAB.Loss.PS.RF]+


ll er t of RAB [VS.RAB.Loss.PS.Abnorm]
release
triggered by
UTRAN per
cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 866


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.HSDPA.RAB.A % HSDPA ([VS.HSDPA.RAB.Loss.Abn


bnormRel.Rate Measuremen orm.NonRF]+
t per cell [VS.HSDPA.RAB.Loss.RF])/
([VS.HSDPA.RAB.Loss.In-
Activity]+
[VS.HSDPA.RAB.Loss.Abno
rm.NonRF]+
[VS.HSDPA.RAB.Loss.RF]+
[VS.HSDPA.RAB.Loss.Norm
]+
[VS.HSDPA.ChR.HSDSCHto
DCH]+
[VS.HSDPA.ChR.HSDSCHto
FACH]+
[VS.HSDPA.HHO.H2D.Suc-
cOutIntraFreq]+
[VS.HSDPA.HHO.H2D.Suc-
cOutInterFreq])*{100.00}

VS.HSDPA.RAB.A none HSDPA [VS.HSDPA.RAB.Loss.Abno


bnormRel Measuremen rm.NonRF]+
t per cell [VS.HSDPA.RAB.Loss.RF]

HO VS.SHO.Factor.RL none Soft ([VS.SHO.AS.1]+


Handover [VS.SHO.AS.2Softer]*{2}+
Measuremen [VS.SHO.AS.2Soft]*{2}+
t per RNC [VS.SHO.AS.3Softer]*{3}+
[VS.SHO.AS.3Soft]*{3}+
[VS.SHO.AS.3Soft2Softer]*
{3}+[VS.SHO.AS.4]*{4}+
[VS.SHO.AS.5]*{5}+
[VS.SHO.AS.6]*{6})/
([VS.SHO.AS.1]+
[VS.SHO.AS.2Softer]+
[VS.SHO.AS.2Soft]+
[VS.SHO.AS.3Softer]+
[VS.SHO.AS.3Soft]+
[VS.SHO.AS.3Soft2Softer]+
[VS.SHO.AS.4]+
[VS.SHO.AS.5]+
[VS.SHO.AS.6])-{1}

Radio.Link.Add.Suc % Soft [SHO.SuccRLAddUESide]/


c.Rate Handover [SHO.AttRLAddUESide]
Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 867


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

SHO.SuccRLAddU times Soft -


ESide Handover
Measuremen
t per cell

SHO.AttRLAddUE- times Soft -


Side Handover
Measuremen
t per cell

Radio.Link.Del.Succ % Soft [SHO.SuccRLDelUESide]/


.Rate Handover [SHO.AttRLDelUESide]
Measuremen
t per cell

SHO.SuccRLDelUE times Soft -


Side Handover
Measuremen
t per cell

SHO.AttRLDelUE- times Soft -


Side Handover
Measuremen
t per cell

VS.SHO.Success.Ce % Soft ([SHO.SuccRLAddUESide]+


ll.Rate Handover [SHO.SuccRLDelUESide])/
Measuremen ([SHO.AttRLAddUESide]+
t per cell [SHO.AttRLDelUESide])*
{100.00}

VS.SHO.SuccUESid none Soft [SHO.SuccRLAddUESide]+


e.Cell Handover [SHO.SuccRLDelUESide]
Measuremen
t per cell

VS.SHO.AttUESide. none Soft [SHO.AttRLAddUESide]+


Cell Handover [SHO.AttRLDelUESide]
Measuremen
t per cell

HO.3G_2G.CS.Rate % InterRAT [IRATHO.SuccOutCS]/


Handover [VS.RAB.SuccEstab.AMR]
Measuremen
t per cell

IRATHO.SuccOutC times InterRAT -


S Handover
Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 868


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.SuccEstab. numb Measuremen -


AMR er t of CS RAB
assignment
setup per cell

VS.IRATHO.SuccO % InterRAT [IRATHO.SuccOutCS]/


utCS.Cell.Rate Handover [IRATHO.AttOutCS]*
Measuremen {100.00}
t per cell

IRATHO.AttOutCS times InterRAT -


Handover
Measuremen
t per cell

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.5 RNC Daily Report

21.5.1 Call TopN Report

Report Type
Simple Report

NE Type
RNC

Object Type
UCell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 869


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

CS Call VS.CS.Call.Drop.Ce numb Measuremen [VS.RAB.Loss.CS.RF]+


Drop ll er t of RAB [VS.RAB.Loss.CS.Abnorm]
Cells release
triggered by
UTRAN per
cell

VS.CS.RAB.Release none Measuremen [VS.RAB.Loss.CS.RF]+


t of RAB [VS.RAB.Loss.CS.Abnorm]+
release [VS.RAB.Loss.CS.Norm]
triggered by
UTRAN per
cell

VS.RAB.RelReqCS. numb Measuremen -


OM er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.RelReqCS. numb Measuremen -


RABPreempt er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.RelReqCS. numb Measuremen -


UTRANgen er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.CS.R numb Measuremen -


F.RLCRst er t of RAB
release
triggered by
UTRAN per
cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 870


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.Loss.CS.R numb Measuremen -


F.ULSync er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.CS.R numb Measuremen -


F.UuNoReply er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.CS.R numb Measuremen -


F.Oth er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.CS.A numb Measuremen -


al2Loss er t of RAB
release
triggered by
UTRAN per
cell

VS.Call.Drop.CS.Ot numb Measuremen [VS.RAB.Loss.CS.Abnorm]-


her er t of RAB [VS.RAB.RelReqCS.OM]-
release [VS.RAB.RelReqCS.UTRAN
triggered by gen]-
UTRAN per [VS.RAB.RelReqCS.RAB-
cell Preempt]-
[VS.RAB.Loss.CS.Aal2Loss]

VP Call VS.CS.VP.Call.Dro none Measuremen [VS.RAB.Loss.CS.Conv64K]


Drops p.Cell t of RAB
release
triggered by
UTRAN per
cell

AMR VS.CS.AMR.Call.D none Measuremen [VS.RAB.Loss.CS.AMR]


Call rop.Cell t of RAB
Drops release
triggered by
UTRAN per
cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 871


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

PS Drop VS.PS.Call.Drop.Ce numb Measuremen [VS.RAB.Loss.PS.RF]+


Cells ll er t of RAB [VS.RAB.Loss.PS.Abnorm]
release
triggered by
UTRAN per
cell

VS.PS.RAB.Release none Measuremen [VS.RAB.Loss.PS.RF]+


t of RAB [VS.RAB.Loss.PS.Abnorm]+
release [VS.RAB.Loss.PS.Norm]
triggered by
UTRAN per
cell

VS.RAB.RelReqPS. numb Measuremen -


OM er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.RelReqPS. numb Measuremen -


RABPreempt er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.PS.R numb Measuremen -


F.RLCRst er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.PS.R numb Measuremen -


F.ULSync er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.PS.R numb Measuremen -


F.UuNoReply er t of RAB
release
triggered by
UTRAN per
cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 872


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.Loss.PS.R numb Measuremen -


F.Oth er t of RAB
release
triggered by
UTRAN per
cell

VS.RAB.Loss.PS.G numb Measuremen -


TPULoss er t of RAB
release
triggered by
UTRAN per
cell

VS.Call.Drop.PS.Ot numb Measuremen [VS.RAB.Loss.PS.Abnorm]-


her er t of RAB [VS.RAB.RelReqPS.OM]-
release [VS.RAB.RelReqPS.RAB-
triggered by Preempt]-
UTRAN per [VS.RAB.Loss.PS.GTPU-
cell Loss]

RRC Fail VS.RRC.FailConnE times RRC [VS.RRC.AttConnEstab.Cell]-


stab.Cell connection [RRC.SuccConnEstab.sum]
setup
measurement
per cell

VS.RRC.AttConEst. none RRC [VS.RRC.AttConEst.DCH]+


Cell connection [VS.RRC.AttConEst.CCH]
setup
measurement
per cell

VS.RRC.Rej.RL.Fai times RRC -


l connection
reject
measurement
per cell

VS.RRC.Rej.TNL.F times RRC -


ail connection
reject
measurement
per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 873


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RRC.Rej.Power. times RRC -


Cong connection
reject
measurement
per cell

VS.RRC.Rej.UL.CE times RRC -


.Cong connection
reject
measurement
per cell

VS.RRC.Rej.DL.CE times RRC -


.Cong connection
reject
measurement
per cell

VS.RRC.Rej.Code.C times RRC -


ong connection
reject
measurement
per cell

VS.RRC.Rej.Other. times RRC [RRC.FailConnEstab.Cong]-


Cong connection [VS.RRC.Rej.Power.Cong]-
reject [VS.RRC.Rej.Code.Cong]-
measurement [VS.RRC.Rej.UL.CE.Cong]-
per cell [VS.RRC.Rej.DL.CE.Cong]

RRC.FailConnEstab. times RRC -


NoReply connection
reject
measurement
per cell

CS RAB VS.RAB.FailEstabC numb Measuremen [VS.RAB.AttEstabCS.Conv]+


FAIL S.Cell er t of CS RAB [VS.RAB.AttEstabCS.Str]-
assignment [VS.RAB.SuccEstabCS.Conv]
setup per cell -[VS.RAB.SuccEstabCS.Str]

VS.RAB.AttEstabC numb Measuremen [VS.RAB.AttEstabCS.Conv]+


S.Cell er t of CS RAB [VS.RAB.AttEstabCS.Str]
assignment
setup per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 874


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.FailEstabC numb Measuremen -


S.TNL er t of CS RAB
assignment
failure per
cell

VS.RAB.FailEstCS. numb Measuremen -


Relo er t of CS RAB
assignment
failure per
cell

VS.RAB.FailEstCS. numb Measuremen -


RIPFail er t of CS RAB
assignment
failure per
cell

VS.RAB.FailEstCs. numb Measuremen -


Power.Cong er t of CS RAB
assignment
failure per
cell

VS.RAB.FailEstCs. numb Measuremen -


ULCE.Cong er t of CS RAB
assignment
failure per
cell

VS.RAB.FailEstCs. numb Measuremen -


DLCE.Cong er t of CS RAB
assignment
failure per
cell

VS.RAB.FailEstCs. numb Measuremen -


Code.Cong er t of CS RAB
assignment
failure per
cell

VS.RAB.FailEstab. numb Measuremen -


CS.DLIUBBand.Co er t of CS RAB
ng assignment
failure per
cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 875


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.FailEstab. numb Measuremen -


CS.ULIUBBand.Co er t of CS RAB
ng assignment
failure per
cell

VS.RAB.FailEstabC numb Measuremen [VS.RAB.FailEstCS.Unsp]-


S.Unsp.Other er t of CS RAB [VS.RAB.FailEstabCS.Cong]
assignment
failure per
cell

VS.RAB.FailEstabC numb Measuremen [VS.RAB.FailEstabCS.RNL]-


S.RNL.Other er t of CS RAB [VS.RAB.FailEstCS.Relo]-
assignment [VS.RAB.FailEstCS.RIPFail]-
failure per [VS.RAB.FailEstabCS.Cong]
cell

VS.RAB.FailEstabC none Measuremen ([VS.RAB.AttEstabCS.Conv]


S.other.CELL t of CS RAB +[VS.RAB.AttEstabCS.Str]-
assignment [VS.RAB.SuccEstabCS.Conv]
setup per cell -[VS.RAB.SuccEstabCS.Str])-
[VS.RAB.FailEstabCS.RNL]-
[VS.RAB.FailEstabCS.TNL]

PS RAB VS.RAB.FailEstabP numb Measuremen ([VS.RAB.AttEstabPS.Conv]


FAIL S.Cell er t of PS RAB +[VS.RAB.AttEstabPS.Str]+
assignment [VS.RAB.AttEstabPS.Inter]+
setup per cell [VS.RAB.AttEstabPS.Bkg])-
([VS.RAB.SuccEstabPS.Conv
]+[VS.RAB.SuccEstabPS.Str]
+[VS.RAB.SuccEstabPS.In-
ter]+
[VS.RAB.SuccEstabPS.Bkg])

VS.RAB.AttEstabPS numb Measuremen [VS.RAB.AttEstabPS.Conv]+


.Cell er t of PS RAB [VS.RAB.AttEstabPS.Str]+
assignment [VS.RAB.AttEstabPS.Inter]+
setup per cell [VS.RAB.AttEstabPS.Bkg]

VS.RAB.FailEstPS. numb Measuremen -


TNL er t of PS RAB
assignment
failure per
cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 876


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.FailEstPS. numb Measuremen -


RIPFail er t of PS RAB
assignment
failure per
cell

VS.RAB.FailEstPS. numb Measuremen -


Par er t of PS RAB
assignment
failure per
cell

VS.RAB.FailEstPS. numb Measuremen -


Relo er t of PS RAB
assignment
failure per
cell

VS.RAB.FailEstPs.P numb Measuremen -


ower.Cong er t of PS RAB
assignment
failure per
cell

VS.RAB.FailEstPs. numb Measuremen -


Code.Cong er t of PS RAB
assignment
failure per
cell

VS.RAB.FailEstPs. numb Measuremen -


ULCE.Cong er t of PS RAB
assignment
failure per
cell

VS.RAB.FailEstPs. numb Measuremen -


DLCE.Cong er t of PS RAB
assignment
failure per
cell

VS.RAB.FailEstab.P numb Measuremen -


S.DLIUBBand.Cong er t of PS RAB
assignment
failure per
cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 877


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.FailEstab.P numb Measuremen -


S.ULIUBBand.Cong er t of PS RAB
assignment
failure per
cell

VS.RAB.FailEstabP none Measuremen [VS.RAB.FailEstPS.Unsp]-


S.Unsp.Other t of PS RAB [VS.RAB.FailEstPs.Power.Co
assignment ng]-
failure per [VS.RAB.FailEstPs.Code.Con
cell g]-
[VS.RAB.FailEstPs.ULCE.Co
ng]-
[VS.RAB.FailEstPs.DLCE.Co
ng]-
[VS.RAB.FailEstab.PS.DLIU
BBand.Cong]-
[VS.RAB.FailEstab.PS.ULIU
BBand.Cong]

VS.RAB.FlEstPS.R numb Measuremen [VS.RAB.FailEstPS.RNL]-


NL.Other er t of PS RAB [VS.RAB.FailEstPS.RIPFail]-
assignment [VS.RAB.FailEstPS.Par]-
failure per [VS.RAB.FailEstPS.Relo]-
cell [VS.RAB.FailEstPS.Unsp]

VS.RAB.FailEstabP numb Measuremen (([VS.RAB.AttEstabPS.Conv]


S.Other.Cell er t of PS RAB +[VS.RAB.AttEstabPS.Str]+
assignment [VS.RAB.AttEstabPS.Inter]+
setup per cell [VS.RAB.AttEstabPS.Bkg])-
([VS.RAB.SuccEstabPS.Conv
]+[VS.RAB.SuccEstabPS.Str]
+[VS.RAB.SuccEstabPS.In-
ter]+
[VS.RAB.SuccEstabPS.Bkg]))
-[VS.RAB.FailEstPS.TNL]-
[VS.RAB.FailEstPS.RNL]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 878


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.5.2 HO TopN Report

Report Type
Simple Report

NE Type
RNC

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

SHO VS.SHO.Fail.Cell none Soft [SHO.AttRLAddUESide]+


FAIL Handover [SHO.AttRLDelUESide]-
Measuremen [SHO.SuccRLAddUESide]-
t per cell [SHO.SuccRLDelUESide]

VS.SHO.AttUESide. none Soft [SHO.AttRLAddUESide]+


Cell Handover [SHO.AttRLDelUESide]
Measuremen
t per cell

SHO.FailRLAddUE times Soft -


Side.CfgUnsup Handover
Measuremen
t per cell

SHO.FailRLAddUE times Soft -


Side.Isr Handover
Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 879


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

SHO.FailRLAddUE times Soft -


Side.InvCfg Handover
Measuremen
t per cell

SHO.FailRLAddUE times Soft -


Side.NoReply Handover
Measuremen
t per cell

VS.SHO.Fail.Other. none Soft ([SHO.AttRLAddUESide]+


Cell Handover [SHO.AttRLDelUESide]-
Measuremen [SHO.SuccRLAddUESide]-
t per cell [SHO.SuccRLDelUESide])-
[SHO.FailRLAddUESide.Cfg
Unsup]-
[SHO.FailRLAddUESide.Isr]-
[SHO.FailRLAddUESide.Inv
Cfg]-
[SHO.FailRLAddUESide.No
Reply]

InterFRe VS.HHO.InterFreq.F none Hard [VS.HHO.InterFreq.AttOut]-


quest ailOut Handover [VS.HHO.InterFreq.SuccOut]
HHO Measuremen
Fail t per cell

VS.HHO.InterFreq. times Hard -


AttOut Handover
Measuremen
t per cell

VS.HHO.InterFreqO times Hard -


ut.CfgUnsupp Handover
Measuremen
t per cell

VS.HHO.InterFreqO times Hard -


ut.PyhChFail Handover
Measuremen
t per cell

VS.HHO.InterFreqO times Hard -


ut.FailUSR Handover
Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 880


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.HHO.InterFreqO times Hard -


ut.CellUpdt Handover
Measuremen
t per cell

VS.HHO.InterFreqO times Hard -


ut.CfgInvalid Handover
Measuremen
t per cell

VS.HHO.InterFreqO times Hard -


ut.NoReply Handover
Measuremen
t per cell

VS.HHO.InterFreq.F none Hard ([VS.HHO.InterFreq.AttOut]-


ailOther Handover [VS.HHO.InterFreq.Suc-
Measuremen cOut])-
t per cell [VS.HHO.InterFreqOut.CfgU
nsupp]-
[VS.HHO.InterFreqOut.PyhC
hFail]-
[VS.HHO.InterFreqOut.Fail-
USR]-
[VS.HHO.InterFreqOut.Cel-
lUpdt]-
[VS.HHO.InterFreqOut.CfgIn
valid]-
[VS.HHO.InterFreqOut.NoRe
ply]

CS VS.IRATHO.Fail- none InterRAT [IRATHO.AttOutCS]-


InterRA OutCS Handover [IRATHO.SuccOutCS]
T HHO Measuremen
FAIL t per cell

IRATHO.AttOutCS times InterRAT -


Handover
Measuremen
t per cell

IRATHO.FailOutCS times InterRAT -


.CfgUnsupp Handover
Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 881


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

IRATHO.FailOutCS times InterRAT -


.PhyChFail Handover
Measuremen
t per cell

VS.IRATHO.FailOu none InterRAT ([IRATHO.AttOutCS]-


tCS.Other Handover [IRATHO.SuccOutCS])-
Measuremen [IRATHO.FailOutCS.CfgUn-
t per cell supp]-
[IRATHO.FailOutCS.PhyCh-
Fail]

PS VS.IRATHO.FailOu none InterRAT [IRATHO.AttOutPSUTRAN]-


InterRA tPSUTRAN.Cell Handover [IRATHO.SuccOutPSU-
T HHO Measuremen TRAN]
FAIL t per cell

IRATHO.AttOut- times InterRAT -


PSUTRAN Handover
Measuremen
t per cell

IRATHO.FailOutPS times InterRAT -


UTRAN.CfgUnsupp Handover
Measuremen
t per cell

IRATHO.FailOutPS times InterRAT -


UTRAN.PhyChFail Handover
Measuremen
t per cell

VS.IRATHO.FailOu none InterRAT [IRATHO.AttOutPSUTRAN]-


tPSUTRAN.Other Handover [IRATHO.SuccOutPSU-
Measuremen TRAN]-
t per cell [IRATHO.FailOutPSUTRAN.
CfgUnsupp]-
[IRATHO.FailOutPSUTRAN.
PhyChFail]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 882


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.5.3 Hot Traffic Cell TopN Report

Report Type
Simple Report

NE Type
RNC

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Hot VS.AMR.Ctrl.DL12. numb Measuremen -


Traffic 2 er t of RB
Cell Procedure
(AMR per cell
Ctrl
DL12.2) VS.RRC.SuccConn % RRC [RRC.SuccConnEstab.sum]/
Estab.Cell.Rate connection [VS.RRC.AttConnEstab.Cell]
setup *{100.00}
measurement
per cell

VS.HHO.InterFreq. % Hard [VS.HHO.InterFreq.SuccOut]/


Out.Cell.Rate Handover [VS.HHO.InterFreq.AttOut]*
Measuremen {100.00}
t per cell

VS.MeanTCP dBm Cell TX and -


RX Power
Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 883


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.MAC.SRNCIub byte Traffic -


BytesPSInt.Tx Measuremen
t per cell

VS.MAC.SRNCIub byte Traffic -


BytesPSBkg.Tx Measuremen
t per cell

VS.MaxRTWP dBm Cell TX and -


RX Power
Measuremen
t per cell

VS.MinRTWP dBm Cell TX and -


RX Power
Measuremen
t per cell

VS.MaxTCP dBm Cell TX and -


RX Power
Measuremen
t per cell

VS.RB.DLConvCS. numb Measuremen -


64 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


64 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


128 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


144 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


384 er t of RB
Procedure
per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 884


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.SuccEstab % Measuremen [VS.RAB.SuccEstab.AMR]/


CS.AMR.Cell.Rate t of CS RAB [VS.RAB.AttEstab.AMR]*
assignment {100.00}
setup per cell

VS.RAB.SuccEstab % Measuremen [VS.RAB.SuccEstCS.Conv.


CS.Conv. t of CS RAB 64]/[VS.RAB.AttEstCS.Conv.
64.Cell.Rate assignment 64]*{100.00}
setup per cell

VS.RAB.SuccEstab % Measuremen ([VS.RAB.SuccEstabPS.Conv


PS.Cell.Rate t of PS RAB ]+[VS.RAB.SuccEstabPS.Str]
assignment +[VS.RAB.SuccEstabPS.In-
setup per cell ter]+
[VS.RAB.SuccEstabPS.Bkg])/
([VS.RAB.AttEstabPS.Conv]
+[VS.RAB.AttEstabPS.Str]+
[VS.RAB.AttEstabPS.Inter]+
[VS.RAB.AttEstabPS.Bkg])*
{100.00}

VS.SuccRBSetup.Ce % Measuremen [VS.SuccRBSetup]/


ll.Rate t of RB [VS.AttRBSetup]*{100.00}
Procedure
per cell

VS.IRATHO.SuccO % InterRAT [IRATHO.SuccOutCS]/


utCS.Cell.Rate Handover [IRATHO.AttOutCS]*
Measuremen {100.00}
t per cell

VS.CS.AMR.Call.D % Measuremen [VS.RAB.Loss.CS.AMR]/


rop.Cell.Rate t of RAB ([VS.RAB.Loss.CS.AMR]+
release [VS.RAB.Loss.CS.Norm.AM
triggered by R])*{100.00}
UTRAN per
cell

VS.CS.VP.Call.Dro % Measuremen [VS.RAB.Loss.CS.Conv64K]/


p.Cell.Rate t of RAB ([VS.RAB.Loss.CS.Conv64K]
release +[VS.Norm.Rel.CS.Conv.RB.
triggered by 64])*{100.00}
UTRAN per
cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 885


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.PS.Call.Drop.Ce % Measuremen ([VS.RAB.Loss.PS.RF]+


ll.Rate t of RAB [VS.RAB.Loss.PS.Abnorm])/
release ([VS.RAB.Loss.PS.RF]+
triggered by [VS.RAB.Loss.PS.Abnorm]+
UTRAN per [VS.RAB.Loss.PS.Norm])*
cell {100.00}

VS.PCH.Utilization. % Traffic [VS.MAC.CRNCIubBytesPC


Cell.Rate Measuremen H.Tx]/
t per cell ([VS.CRNC.IUB.PCH.Band-
width]*{GP}*{60})*{100.00}

VS.FACH.Utilizatio % Traffic [VS.MAC.CRNCIubBytesFA


n.Cell.Rate Measuremen CH.Tx]/
t per cell ([VS.CRNC.IUB.FACH.Band
width]*{GP}*{60})*{100.00}

VS.RACH.Utilizatio % Traffic [VS.MAC.CRNCIubBytesRA


n.Cell.Rate Measuremen CH.Rx]/
t per cell ([VS.CRNC.IUB.RACH.Band
width]*{GP}*{60})*{100.00}

Hot VS.RB.DLInterPS. numb Measuremen -


Traffic 384 er t of RB
Cell(RB Procedure
DLInterP per cell
S 384)
VS.RRC.SuccConn % RRC [RRC.SuccConnEstab.sum]/
Estab.Cell.Rate connection [VS.RRC.AttConnEstab.Cell]
setup *{100.00}
measurement
per cell

VS.HHO.InterFreq. % Hard [VS.HHO.InterFreq.SuccOut]/


Out.Cell.Rate Handover [VS.HHO.InterFreq.AttOut]*
Measuremen {100.00}
t per cell

VS.MeanTCP dBm Cell TX and -


RX Power
Measuremen
t per cell

VS.MAC.SRNCIub byte Traffic -


BytesPSInt.Tx Measuremen
t per cell

VS.MAC.SRNCIub byte Traffic -


BytesPSBkg.Tx Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 886


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.MaxRTWP dBm Cell TX and -


RX Power
Measuremen
t per cell

VS.MinRTWP dBm Cell TX and -


RX Power
Measuremen
t per cell

VS.MaxTCP dBm Cell TX and -


RX Power
Measuremen
t per cell

VS.AMR.Ctrl.DL12. numb Measuremen -


2 er t of RB
Procedure
per cell

VS.RB.DLConvCS. numb Measuremen -


64 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


64 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


128 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


144 er t of RB
Procedure
per cell

VS.RAB.SuccEstab % Measuremen [VS.RAB.SuccEstab.AMR]/


CS.AMR.Cell.Rate t of CS RAB [VS.RAB.AttEstab.AMR]*
assignment {100.00}
setup per cell

VS.RAB.SuccEstab % Measuremen [VS.RAB.SuccEstCS.Conv.


CS.Conv. t of CS RAB 64]/[VS.RAB.AttEstCS.Conv.
64.Cell.Rate assignment 64]*{100.00}
setup per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 887


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.SuccEstab % Measuremen ([VS.RAB.SuccEstabPS.Conv


PS.Cell.Rate t of PS RAB ]+[VS.RAB.SuccEstabPS.Str]
assignment +[VS.RAB.SuccEstabPS.In-
setup per cell ter]+
[VS.RAB.SuccEstabPS.Bkg])/
([VS.RAB.AttEstabPS.Conv]
+[VS.RAB.AttEstabPS.Str]+
[VS.RAB.AttEstabPS.Inter]+
[VS.RAB.AttEstabPS.Bkg])*
{100.00}

VS.SuccRBSetup.Ce % Measuremen [VS.SuccRBSetup]/


ll.Rate t of RB [VS.AttRBSetup]*{100.00}
Procedure
per cell

VS.IRATHO.SuccO % InterRAT [IRATHO.SuccOutCS]/


utCS.Cell.Rate Handover [IRATHO.AttOutCS]*
Measuremen {100.00}
t per cell

VS.CS.AMR.Call.D % Measuremen [VS.RAB.Loss.CS.AMR]/


rop.Cell.Rate t of RAB ([VS.RAB.Loss.CS.AMR]+
release [VS.RAB.Loss.CS.Norm.AM
triggered by R])*{100.00}
UTRAN per
cell

VS.CS.VP.Call.Dro % Measuremen [VS.RAB.Loss.CS.Conv64K]/


p.Cell.Rate t of RAB ([VS.RAB.Loss.CS.Conv64K]
release +[VS.Norm.Rel.CS.Conv.RB.
triggered by 64])*{100.00}
UTRAN per
cell

VS.PS.Call.Drop.Ce % Measuremen ([VS.RAB.Loss.PS.RF]+


ll.Rate t of RAB [VS.RAB.Loss.PS.Abnorm])/
release ([VS.RAB.Loss.PS.RF]+
triggered by [VS.RAB.Loss.PS.Abnorm]+
UTRAN per [VS.RAB.Loss.PS.Norm])*
cell {100.00}

VS.PCH.Utilization. % Traffic [VS.MAC.CRNCIubBytesPC


Cell.Rate Measuremen H.Tx]/
t per cell ([VS.CRNC.IUB.PCH.Band-
width]*{GP}*{60})*{100.00}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 888


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.FACH.Utilizatio % Traffic [VS.MAC.CRNCIubBytesFA


n.Cell.Rate Measuremen CH.Tx]/
t per cell ([VS.CRNC.IUB.FACH.Band
width]*{GP}*{60})*{100.00}

VS.RACH.Utilizatio % Traffic [VS.MAC.CRNCIubBytesRA


n.Cell.Rate Measuremen CH.Rx]/
t per cell ([VS.CRNC.IUB.RACH.Band
width]*{GP}*{60})*{100.00}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.5.4 HSDPA KPI Daily Report

Report Type
Simple Report

NE Type
RNC

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

HSDPA VS.HSDPA.MeanC none HSDPA [VS.HSDPA.MeanChThrough


Traffic hThroughput.Total- Measuremen put.TotalBytes]/({1024}*
MBytes t per cell {1024})

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 889


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.HSDPA.UE.Mea numb HSDPA -


n.Cell er Measuremen
t per cell

VS.HSDPA.MeanC none HSDPA ([VS.HSDPA.MeanChThroug


hThroughput.To- Measuremen hput.TotalBytes]*{8.0}/
talMBps t per cell ({1024.0}*{1024.0}))/({GP}*
{60})

HSDPA VS.HSDPA.RAB.Su % HSDPA [VS.HSDPA.RAB.SuccEs-


Access ccEstab.Rate Measuremen tab]/[VS.HSDPA.RAB.AttEs-
t per cell tab]*{100.00}

VS.HSDPA.RAB.Su times HSDPA -


ccEstab Measuremen
t per cell

VS.HSDPA.RAB.At times HSDPA -


tEstab Measuremen
t per cell

HSDPA VS.HSDPA.ServCel % HSDPA [VS.HSDPA.SHO.CellChg.Su


HO lChg.Succ.Rate Measuremen ccOut]/
t per cell [VS.HSDPA.SHO.CellChg.At
tOut]*{100.00}

VS.HSDPA.SHO.Ce times HSDPA -


llChg.SuccOut Measuremen
t per cell

VS.HSDPA.SHO.Ce times HSDPA -


llChg.AttOut Measuremen
t per cell

VS.HSDPA.HHO.In % HSDPA [VS.HSDPA.HHO.SuccOu-


traFreq.NoChR.Succ Measuremen tIntraFreq]/
.Rate t per cell [VS.HSDPA.HHO.AttOutIn-
traFreq]*{100.00}

VS.HSDPA.HHO.S times HSDPA -


uccOutIntraFreq Measuremen
t per cell

VS.HSDPA.HHO.At times HSDPA -


tOutIntraFreq Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 890


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.HSDPA.HHO.In % HSDPA [VS.HSDPA.HHO.SuccOu-


terFreq.NoChR.Succ Measuremen tInterFreq]/
.Rate t per cell [VS.HSDPA.HHO.AttOutIn-
terFreq]*{100.00}

VS.HSDPA.HHO.S times HSDPA -


uccOutInterFreq Measuremen
t per cell

VS.HSDPA.HHO.At times HSDPA -


tOutInterFreq Measuremen
t per cell

VS.HSDPA.ChR.HS % HSDPA [VS.HSDPA.ChR.HSDSCHto


DSCHtoDCH.Succ. Measuremen DCH]/
Rate t per cell [VS.HSDPA.ChR.HSDSCHto
DCH.Att]*{100.00}

VS.HSDPA.ChR.HS times HSDPA -


DSCHtoDCH Measuremen
t per cell

VS.HSDPA.ChR.HS times HSDPA -


DSCHtoDCH.Att Measuremen
t per cell

VS.HSDPA.ChR.D % HSDPA [VS.HSDPA.ChR.DCHtoHSD


CHtoHSDSCH.Succ Measuremen SCH]/
.Rate t per cell [VS.HSDPA.ChR.DCHtoHSD
SCH.Att]*{100.00}

VS.HSDPA.ChR.D times HSDPA -


CHtoHSDSCH Measuremen
t per cell

VS.HSDPA.ChR.D times HSDPA -


CHtoHSDSCH.Att Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 891


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

HSDPA VS.HSDPA.RAB.A % HSDPA ([VS.HSDPA.RAB.Loss.Abn


CDR bnormRel.Rate Measuremen orm.NonRF]+
t per cell [VS.HSDPA.RAB.Loss.RF])/
([VS.HSDPA.RAB.Loss.In-
Activity]+
[VS.HSDPA.RAB.Loss.Abno
rm.NonRF]+
[VS.HSDPA.RAB.Loss.RF]+
[VS.HSDPA.RAB.Loss.Norm
]+
[VS.HSDPA.ChR.HSDSCHto
DCH]+
[VS.HSDPA.ChR.HSDSCHto
FACH]+
[VS.HSDPA.HHO.H2D.Suc-
cOutIntraFreq]+
[VS.HSDPA.HHO.H2D.Suc-
cOutInterFreq])*{100.00}

VS.HSDPA.RAB.A none HSDPA [VS.HSDPA.RAB.Loss.Abno


bnormRel Measuremen rm.NonRF]+
t per cell [VS.HSDPA.RAB.Loss.RF]

VS.HSDPA.RAB.Re none HSDPA [VS.HSDPA.RAB.Loss.InAc-


l Measuremen tivity]+
t per cell [VS.HSDPA.RAB.Loss.Abno
rm.NonRF]+
[VS.HSDPA.RAB.Loss.RF]+
[VS.HSDPA.RAB.Loss.Norm
]+
[VS.HSDPA.ChR.HSDSCHto
DCH]+
[VS.HSDPA.ChR.HSDSCHto
FACH]+
[VS.HSDPA.HHO.H2D.Suc-
cOutIntraFreq]+
[VS.HSDPA.HHO.H2D.Suc-
cOutInterFreq]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 892


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.5.5 HSDPA TopN Report

Report Type
Simple Report

NE Type
RNC

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

HSDPA VS.HSDPA.RAB.Fa none HSDPA [VS.HSDPA.RAB.AttEstab]-


RAB Fail ilEstab Measuremen [VS.HSDPA.RAB.SuccEstab]
t per cell

VS.HSDPA.RAB.At times HSDPA -


tEstab Measuremen
t per cell

HSDPA VS.HSDPA.RAB.A none HSDPA [VS.HSDPA.RAB.Loss.Abno


RAB bnormRel Measuremen rm.NonRF]+
Abnorm t per cell [VS.HSDPA.RAB.Loss.RF]
Rel

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 893


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.HSDPA.RAB.Re none HSDPA [VS.HSDPA.RAB.Loss.InAc-


l Measuremen tivity]+
t per cell [VS.HSDPA.RAB.Loss.Abno
rm.NonRF]+
[VS.HSDPA.RAB.Loss.RF]+
[VS.HSDPA.RAB.Loss.Norm
]+
[VS.HSDPA.ChR.HSDSCHto
DCH]+
[VS.HSDPA.ChR.HSDSCHto
FACH]+
[VS.HSDPA.HHO.H2D.Suc-
cOutIntraFreq]+
[VS.HSDPA.HHO.H2D.Suc-
cOutInterFreq]

VS.HSDPA.MeanC none HSDPA ({8}*


hThroughput.NEW Measuremen [VS.HSDPA.MeanChThrough
t per cell put.TotalBytes]/
([VS.HSDPA.MeanChThroug
hput.Times]))

VS.HSDPA.MeanC byte HSDPA -


hThroughput.Total- Measuremen
Bytes t per cell

VS.HSDPA.UE.Mea numb HSDPA -


n.Cell er Measuremen
t per cell

VS.HSDPA.MACD. numb HSDPA -


Mean.Cell er Measuremen
t per cell

HSDPA VS.HSDPA.ServCel none HSDPA [VS.HSDPA.HHO.AttOutIn-


HHO lChg.HHO.IntraFreq Measuremen traFreq]-
IntraFRe .NoChR.Fail t per cell [VS.HSDPA.HHO.SuccOu-
quest Fail tIntraFreq]

VS.HSDPA.HHO.At times HSDPA -


tOutIntraFreq Measuremen
t per cell

HSDPA VS.HSDPA.ServCel none HSDPA [VS.HSDPA.HHO.AttOutIn-


HHO lChg.HHO.InterFreq Measuremen terFreq]-
InterFRe .NoChR.Fail t per cell [VS.HSDPA.HHO.SuccOu-
quest Fail tInterFreq]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 894


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.HSDPA.HHO.At times HSDPA -


tOutInterFreq Measuremen
t per cell

HSDPA VS.HSDPA.ChR.HS none HSDPA [VS.HSDPA.ChR.HSDSCHto


HSDSC DSCHtoDCH.Fail Measuremen DCH.Att]-
HtoDCH t per cell [VS.HSDPA.ChR.HSDSCHto
Fail DCH]

VS.HSDPA.ChR.HS times HSDPA -


DSCHtoDCH.Att Measuremen
t per cell

HSDPA VS.HSDPA.ChR.D none HSDPA [VS.HSDPA.ChR.DCHtoHSD


DCHtoH CHtoHSDSCH.Fail Measuremen SCH.Att]-
SDSCH t per cell [VS.HSDPA.ChR.DCHtoHSD
Fail SCH]

VS.HSDPA.ChR.D times HSDPA -


CHtoHSDSCH.Att Measuremen
t per cell

HSDPA VS.HSDPA.ServCel none HSDPA [VS.HSDPA.SHO.CellChg.At


ServCell lChg.SHO.Fail Measuremen tOut]-
Chg Fail t per cell [VS.HSDPA.SHO.CellChg.Su
ccOut]

VS.HSDPA.SHO.Ce times HSDPA -


llChg.AttOut Measuremen
t per cell

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.5.6 HSUPA KPI Daily Report

Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 895


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

NE Type
RNC

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

HSUPA VS.HSUPA.RAB.Su % HSUPA [VS.HSUPA.RAB.SuccEs-


Access ccEstab.Rate Measuremen tab]/[VS.HSUPA.RAB.AttEs-
t per cell tab]*{100.00}

VS.HSUPA.RAB.Su numb HSUPA -


ccEstab er Measuremen
t per cell

VS.HSUPA.RAB.At numb HSUPA -


tEstab er Measuremen
t per cell

HSUPA VS.HSUPA.EDCH. % HSUPA [VS.HSUPA.EDCH.SHO.Suc


HO SHO.Succ.Ratio Measuremen c]/
t per cell [VS.HSUPA.EDCH.SHO.Att]
*{100.00}

VS.HSUPA.EDCH. times HSUPA -


SHO.Succ Measuremen
t per cell

VS.HSUPA.EDCH. times HSUPA -


SHO.Att Measuremen
t per cell

VS.HSUPA.SHO.Se % HSUPA [VS.HSUPA.SHO.ServCellCh


rvCellChg.Succ.Ra- Measuremen g.Succ]/
tio t per cell [VS.HSUPA.SHO.ServCellCh
g.Att]*{100.00}

VS.HSUPA.SHO.Se times HSUPA -


rvCellChg.Succ Measuremen
t per cell

VS.HSUPA.SHO.Se times HSUPA -


rvCellChg.Att Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 896


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.HSUPA.HHO.In % HSUPA [VS.HSUPA.HHO.InterFreq.


terFreq.NoChR.Succ Measuremen NoChR.Succ]/
.Ratio t per cell [VS.HSUPA.HHO.InterFreq.
NoChR.Att]*{100.00}

VS.HSUPA.HHO.In times HSUPA -


terFreq.NoChR.Succ Measuremen
t per cell

VS.HSUPA.HHO.In times HSUPA -


terFreq.NoChR.Att Measuremen
t per cell

HSUPA VS.HSUPA.RAB.A % HSUPA ([VS.HSUPA.RAB.Loss.Ab-


CDR bnormRel.Rate Measuremen norm])/
t per cell ([VS.HSUPA.RAB.Loss.Ab-
norm]+
[VS.HSUPA.RAB.Loss.Norm
]+
[VS.HSUPA.ChR.IntraCell.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.IntraFreq.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.InterFreq.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.EDCHtoFA
CH.Succ])*{100.00}

VS.HSUPA.RAB.A none HSUPA [VS.HSUPA.RAB.Loss.Ab-


bnormRel Measuremen norm]
t per cell

VS.HSUPA.RAB.Re none HSUPA [VS.HSUPA.RAB.Loss.Ab-


lease Measuremen norm]+
t per cell [VS.HSUPA.RAB.Loss.Norm
]+
[VS.HSUPA.ChR.IntraCell.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.IntraFreq.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.InterFreq.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.EDCHtoFA
CH.Succ]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 897


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.5.7 HSUPA TopN Report

Report Type
Simple Report

NE Type
RNC

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

HSUPA VS.HSUPA.RAB.Fa none HSUPA [VS.HSUPA.RAB.AttEstab]-


RAB ilEstab Measuremen [VS.HSUPA.RAB.SuccEstab]
FailEstab t per cell

VS.HSUPA.RAB.At numb HSUPA -


tEstab er Measuremen
t per cell

HSUPA VS.HSUPA.RAB.A none HSUPA [VS.HSUPA.RAB.Loss.Ab-


RAB bnormRel Measuremen norm]
Abnorm t per cell
Release

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 898


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.HSUPA.RAB.Re none HSUPA [VS.HSUPA.RAB.Loss.Ab-


lease Measuremen norm]+
t per cell [VS.HSUPA.RAB.Loss.Norm
]+
[VS.HSUPA.ChR.IntraCell.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.IntraFreq.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.InterFreq.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.EDCHtoFA
CH.Succ]

HSUPA VS.HSUPA.EDCH. none HSUPA [VS.HSUPA.EDCH.SHO.Att]


EDCH SHO.Fail Measuremen -
SHO Fail t per cell [VS.HSUPA.EDCH.SHO.Suc
c]

VS.HSUPA.EDCH. times HSUPA -


SHO.Att Measuremen
t per cell

HSUPA VS.HSUPA.SHO.Se none HSUPA [VS.HSUPA.SHO.ServCellCh


SHO rvCellChg.Fail Measuremen g.Att]-
ServCell t per cell [VS.HSUPA.SHO.ServCellCh
Chg Fail g.Succ]

VS.HSUPA.SHO.Se times HSUPA -


rvCellChg.Att Measuremen
t per cell

HSUPA VS.HSUPA.HHO.In none HSUPA [VS.HSUPA.HHO.InterFreq.


HHO terFreq.NoChR.Fail Measuremen NoChR.Att]-
InterFRe t per cell [VS.HSUPA.HHO.InterFreq.
quest NoChR.Succ]
NoChR
Fail VS.HSUPA.HHO.In times HSUPA -
terFreq.NoChR.Att Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 899


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.5.8 RNC All Service Daily Report

Report Type
Simple Report

NE Type
RNC

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Traffic VS.AMR.RB.DL. numb Measuremen -


12.2 er t related to
AMR service

VS.RB.DLConvCS. numb Measuremen -


64.RNC er t of RB
Procedure
per RNC

VS.CSLoad.Erlang. none Traffic -


Equiv.RNC Measuremen
t per RNC

VS.R99PSLoad.UL kbit/s Traffic -


Thruput.RNC Measuremen
t per RNC

VS.R99PSLoad.DL kbit/s Traffic -


Thruput.RNC Measuremen
t per RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 900


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.HSUPAPSLoad. kbit/s Traffic -


ULThruput.RNC Measuremen
t per RNC

VS.HSDPAPSLoad. kbit/s Traffic -


DLThruput.RNC Measuremen
t per RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 901


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Access VS.RRC.SuccConn % RRC ([RRC.SuccConnEstab.Og-


Estab.Service.Cell.R connection ConvCall]+
ate setup [RRC.SuccConnEstab.OrgStr-
measurement Call]+
per cell [RRC.SuccConnEstab.OrgItr-
Call]+
[RRC.SuccConnEstab.OrgBk
gCall]+
[RRC.SuccConnEstab.Org-
SubCall]+
[RRC.SuccConnEstab.TmCon
vCall]+
[RRC.SuccConnEstab.TmStr
Call]+
[RRC.SuccConnEstab.TmItr-
Call]+
[RRC.SuccConnEstab.TmBkg
Call]+
[RRC.SuccConnEstab.Emg-
Call]+
[RRC.SuccConnEstab.Un-
kown]+
[RRC.SuccConnEstab.OgHhP
rSig]+
[RRC.SuccConnEstab.OgLwP
rSig]+
[RRC.SuccConnEstab.CallRe-
Est]+
[RRC.SuccConnEstab.TmHhP
rSig]+
[RRC.SuccConnEstab.TmLw
PrSig])/
([RRC.AttConnEstab.Org-
ConvCall]+
[RRC.AttConnEstab.OrgStr-
Call]+
[RRC.AttConnEstab.OrgInter-
Call]+
[RRC.AttConnEstab.OrgBkg-
Call]+
[RRC.AttConnEstab.OgSub-
Call]+
[RRC.AttConnEstab.TmConv
Call]+
[RRC.AttConnEstab.TmStrCa
ll]+
[RRC.AttConnEstab.TmInter-

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 902


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Call]+
[RRC.AttConnEstab.TmBkgC
all]+
[RRC.AttConnEstab.Emg-
Call]+
[RRC.AttConnEstab.Un-
known]+
[RRC.AttConnEstab.OgHhPr-
Sig]+
[RRC.AttConnEstab.OgLwPr-
Sig]+
[RRC.AttConnEstab.CallRe-
Est]+
[RRC.AttConnEstab.TmHhPr
Sig]+
[RRC.AttConnEstab.TmLwPr
Sig])*{100.00}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 903


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RRC.SuccConn none RRC [RRC.SuccConnEstab.Og-


Estab.Service.Cell connection ConvCall]+
setup [RRC.SuccConnEstab.OrgStr-
measurement Call]+
per cell [RRC.SuccConnEstab.OrgItr-
Call]+
[RRC.SuccConnEstab.OrgBk
gCall]+
[RRC.SuccConnEstab.Org-
SubCall]+
[RRC.SuccConnEstab.TmCon
vCall]+
[RRC.SuccConnEstab.TmStr
Call]+
[RRC.SuccConnEstab.TmItr-
Call]+
[RRC.SuccConnEstab.TmBkg
Call]+
[RRC.SuccConnEstab.Emg-
Call]+
[RRC.SuccConnEstab.Un-
kown]+
[RRC.SuccConnEstab.OgHhP
rSig]+
[RRC.SuccConnEstab.OgLwP
rSig]+
[RRC.SuccConnEstab.CallRe-
Est]+
[RRC.SuccConnEstab.TmHhP
rSig]+
[RRC.SuccConnEstab.TmLw
PrSig]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 904


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RRC.AttConnEs none RRC [RRC.AttConnEstab.Org-


tab.Service.Cell connection ConvCall]+
setup [RRC.AttConnEstab.OrgStr-
measurement Call]+
per cell [RRC.AttConnEstab.OrgInter-
Call]+
[RRC.AttConnEstab.OrgBkg-
Call]+
[RRC.AttConnEstab.OgSub-
Call]+
[RRC.AttConnEstab.TmConv
Call]+
[RRC.AttConnEstab.TmStrCa
ll]+
[RRC.AttConnEstab.TmInter-
Call]+
[RRC.AttConnEstab.TmBkgC
all]+
[RRC.AttConnEstab.Emg-
Call]+
[RRC.AttConnEstab.Un-
known]+
[RRC.AttConnEstab.OgHhPr-
Sig]+
[RRC.AttConnEstab.OgLwPr-
Sig]+
[RRC.AttConnEstab.CallRe-
Est]+
[RRC.AttConnEstab.TmHhPr
Sig]+
[RRC.AttConnEstab.TmLwPr
Sig]

VS.RRC.SuccConn % RRC ([RRC.SuccConnEstab.IRAT-


Estab.Other.Cell.Rat connection CelRes]+
e setup [RRC.SuccConnEstab.IRATC
measurement CO]+
per cell [RRC.SuccConnEstab.Reg]+
[RRC.SuccConnEstab.De-
tach])/
([RRC.AttConnEstab.IRAT-
CelRes]+
[RRC.AttConnEstab.IRATC-
CO]+
[RRC.AttConnEstab.Reg]+
[RRC.AttConnEstab.Detach])
*{100.00}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 905


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RRC.SuccConn none RRC [RRC.SuccConnEstab.IRAT-


Estab.Other.Cell connection CelRes]+
setup [RRC.SuccConnEstab.IRATC
measurement CO]+
per cell [RRC.SuccConnEstab.Reg]+
[RRC.SuccConnEstab.Detach]

VS.RRC.AttConnEs none RRC [RRC.AttConnEstab.IRAT-


tab.Other.Cell connection CelRes]+
setup [RRC.AttConnEstab.IRATC-
measurement CO]+
per cell [RRC.AttConnEstab.Reg]+
[RRC.AttConnEstab.Detach]

VS.RAB.SuccEstab % Measuremen [VS.RAB.SuccEstab.AMR]/


CS.AMR.Cell.Rate t of CS RAB [VS.RAB.AttEstab.AMR]*
assignment {100.00}
setup per cell

VS.RAB.SuccEstab. numb Measuremen -


AMR er t of CS RAB
assignment
setup per cell

VS.RAB.AttEstab.A numb Measuremen -


MR er t of CS RAB
assignment
setup per cell

VS.RAB.SuccEstab % Measuremen [VS.RAB.SuccEstCS.Conv.


CS.Conv. t of CS RAB 64]/[VS.RAB.AttEstCS.Conv.
64.Cell.Rate assignment 64]*{100.00}
setup per cell

VS.RAB.SuccEstCS numb Measuremen -


.Conv.64 er t of CS RAB
assignment
setup per cell

VS.RAB.AttEstCS. numb Measuremen -


Conv.64 er t of CS RAB
assignment
setup per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 906


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.SuccEstab % Measuremen ([VS.RAB.SuccEstabPS.Conv


PS.Cell.Rate t of PS RAB ]+[VS.RAB.SuccEstabPS.Str]
assignment +[VS.RAB.SuccEstabPS.In-
setup per cell ter]+
[VS.RAB.SuccEstabPS.Bkg])/
([VS.RAB.AttEstabPS.Conv]
+[VS.RAB.AttEstabPS.Str]+
[VS.RAB.AttEstabPS.Inter]+
[VS.RAB.AttEstabPS.Bkg])*
{100.00}

VS.RAB.SuccEstPS. none Measuremen [VS.RAB.SuccEstabPS.Conv]


Cell t of PS RAB +[VS.RAB.SuccEstabPS.Str]+
assignment [VS.RAB.SuccEstabPS.Inter]
setup per cell +[VS.RAB.SuccEstabPS.Bkg]

VS.RAB.AttEstabPS numb Measuremen [VS.RAB.AttEstabPS.Conv]+


.Cell er t of PS RAB [VS.RAB.AttEstabPS.Str]+
assignment [VS.RAB.AttEstabPS.Inter]+
setup per cell [VS.RAB.AttEstabPS.Bkg]

HO VS.SHO.Factor.RL none Soft ([VS.SHO.AS.1]+


Handover [VS.SHO.AS.2Softer]*{2}+
Measuremen [VS.SHO.AS.2Soft]*{2}+
t per RNC [VS.SHO.AS.3Softer]*{3}+
[VS.SHO.AS.3Soft]*{3}+
[VS.SHO.AS.3Soft2Softer]*
{3}+[VS.SHO.AS.4]*{4}+
[VS.SHO.AS.5]*{5}+
[VS.SHO.AS.6]*{6})/
([VS.SHO.AS.1]+
[VS.SHO.AS.2Softer]+
[VS.SHO.AS.2Soft]+
[VS.SHO.AS.3Softer]+
[VS.SHO.AS.3Soft]+
[VS.SHO.AS.3Soft2Softer]+
[VS.SHO.AS.4]+
[VS.SHO.AS.5]+
[VS.SHO.AS.6])-{1}

VS.SHO.Succ.Rate % Soft [VS.SHO.Succ]/


Handover [VS.SHO.Att.RNC]*{100.00}
Measuremen
t per RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 907


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.SHO.Succ times Soft -


Handover
Measuremen
t per RNC

VS.SHO.Att.RNC times Soft -


Handover
Measuremen
t per RNC

VS.InterFreq.HHO.S % Hard [VS.HHO.InterFreq.Succ.RN


ucc.RNC.Rate Handover C]/
Measuremen [VS.HHO.InterFreq.Att.RNC]
t per RNC *{100.00}

VS.HHO.InterFreq.S times Hard -


ucc.RNC Handover
Measuremen
t per RNC

VS.HHO.InterFreq. times Hard -


Att.RNC Handover
Measuremen
t per RNC

VS.IRATHO.SuccC % Measuremen [VS.IRATHO.SuccCSOut.RN


SOut.RNC.Rate t related to C]/
CS IRA [VS.IRATHO.AttCSOut.RNC
handover per ]*{100.00}
RNC

VS.IRATHO.SuccC times Measuremen -


SOut.RNC t related to
CS IRA
handover per
RNC

VS.IRATHO.AttCS times Measuremen -


Out.RNC t related to
CS IRA
handover per
RNC

VS.IRATHO.SuccP % Measuremen [VS.IRATHO.SuccPSOutUT


SOutUTRAN.RNC. t related to PS RAN.RNC]/
Rate IRA [VS.IRATHO.AttPSOutUTR
handover per AN.RNC]*{100.00}
RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 908


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.IRATHO.SuccP times Measuremen -


SOutUTRAN.RNC t related to PS
IRA
handover per
RNC

VS.IRATHO.AttPS times Measuremen -


OutUTRAN.RNC t related to PS
IRA
handover per
RNC

CDR VS.Abnorm.Rel.CS. times Measuremen -


AMR.IurLink t related to
SRNC in Iur
interface

VS.Rel.CS.AMR.Iur none Measuremen [VS.Norm.Rel.CS.AMR.Iur-


Link t related to Link]+
SRNC in Iur [VS.Abnorm.Rel.CS.AMR.Iur
interface Link]

VS.RAB.Loss.CS.A numb Measuremen -


MR er t of RAB
release
triggered by
UTRAN per
cell

VS.CS.AMR.Re- none Measuremen [VS.RAB.Loss.CS.AMR]+


lease t of RAB [VS.RAB.Loss.CS.Norm.AM
release R]
triggered by
UTRAN per
cell

VS.Abnorm.Rel.CS. times Measuremen -


Conv.RB.64.IurLink t related to
SRNC in Iur
interface

VS.Rel.CS.VP.Iur- none Measuremen [VS.Norm.Rel.CS.Conv.RB.


Link t related to 64.IurLink]+
SRNC in Iur [VS.Abnorm.Rel.CS.Conv.RB
interface .64.IurLink]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 909


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.Loss.CS.C numb Measuremen -


onv64K er t of RAB
release
triggered by
UTRAN per
cell

VS.CS.VP.Release none Measuremen [VS.RAB.Loss.CS.Conv64K]


t of RAB +[VS.Norm.Rel.CS.Conv.RB.
release 64]
triggered by
UTRAN per
cell

VS.Abnorm.Rel.PS.I none Measuremen [VS.Abnorm.Rel.PS.BE.RB.


urLink t related to 0.32.IurLink]+
SRNC in Iur [VS.Abnorm.Rel.PS.BE.RB.
interface 32.64.IurLink]+
[VS.Abnorm.Rel.PS.BE.RB.
64.144.IurLink]+
[VS.Abnorm.Rel.PS.BE.RB.
144.384.IurLink]+
[VS.Abnorm.Rel.PS.CCH.Iur-
Link]

VS.Rel.PS.IurLink none Measuremen [VS.Norm.Rel.PS.BE.RB.


t related to 0.32.IurLink]+
SRNC in Iur [VS.Norm.Rel.PS.BE.RB.
interface 32.64.IurLink]+
[VS.Norm.Rel.PS.BE.RB.
64.144.IurLink]+
[VS.Norm.Rel.PS.BE.RB.
144.384.IurLink]+
[VS.Norm.Rel.PS.CCH.Iur-
Link]+
[VS.Abnorm.Rel.PS.BE.RB.
0.32.IurLink]+
[VS.Abnorm.Rel.PS.BE.RB.
32.64.IurLink]+
[VS.Abnorm.Rel.PS.BE.RB.
64.144.IurLink]+
[VS.Abnorm.Rel.PS.BE.RB.
144.384.IurLink]+
[VS.Abnorm.Rel.PS.CCH.Iur-
Link]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 910


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.PS.Call.Drop.Ce numb Measuremen [VS.RAB.Loss.PS.RF]+


ll er t of RAB [VS.RAB.Loss.PS.Abnorm]
release
triggered by
UTRAN per
cell

VS.PS.RAB.Release none Measuremen [VS.RAB.Loss.PS.RF]+


t of RAB [VS.RAB.Loss.PS.Abnorm]+
release [VS.RAB.Loss.PS.Norm]
triggered by
UTRAN per
cell

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.5.9 Traffic Cell TopN Report

Report Type
Simple Report

NE Type
RNC

Object Type
UCell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 911


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

RRC RRC.FailConnEstab. times RRC -


Cong Cong connection
Cell reject
TopN measurement
per cell

VS.RRC.Rej.Power. times RRC -


Cong connection
reject
measurement
per cell

VS.RRC.Rej.UL.CE times RRC -


.Cong connection
reject
measurement
per cell

VS.RRC.Rej.DL.CE times RRC -


.Cong connection
reject
measurement
per cell

VS.RRC.Rej.Code.C times RRC -


ong connection
reject
measurement
per cell

VS.RRC.Rej.TNL.F times RRC -


ail connection
reject
measurement
per cell

VS.AMR.Ctrl.DL12. numb Measuremen -


2 er t of RB
Procedure
per cell

VS.RB.DLConvCS. numb Measuremen -


64 er t of RB
Procedure
per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 912


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RB.ULInterPS. numb Measuremen -


64 er t of RB
Procedure
per cell

VS.RB.ULInterPS. numb Measuremen -


128 er t of RB
Procedure
per cell

VS.RB.ULInterPS. numb Measuremen -


144 er t of RB
Procedure
per cell

VS.RB.ULInterPS. numb Measuremen -


384 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


64 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


128 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


144 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


384 er t of RB
Procedure
per cell

VS.MAC.SRNCIub byte Traffic -


BytesPSInt.Tx Measuremen
t per cell

VS.MAC.SRNCIub byte Traffic -


BytesPSBkg.Tx Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 913


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.LC.ULCreditUse none Measuremen -


d.CELL t related to
Algorithm
per cell

VS.LC.DLCreditUse none Measuremen -


d.CELL t related to
Algorithm
per cell

RAB VS.RAB.FailEstabP none Measuremen [VS.RAB.Block.PS.Bkg.0.32]


Cong S.Cong t of PS RAB +[VS.RAB.Block.PS.Bkg.
Cell assignment 144.384]+
TopN failure per [VS.RAB.Block.PS.Bkg.
cell 32.64]+
[VS.RAB.Block.PS.Bkg.
64.144]+
[VS.RAB.Block.PS.Conv.
0.32]+[VS.RAB.Block.PS.Int.
0.32]+[VS.RAB.Block.PS.Int.
144.384]+
[VS.RAB.Block.PS.Int.32.64]
+[VS.RAB.Block.PS.Int.
64.144]+
[VS.RAB.Block.PS.Str.0.32]+
[VS.RAB.Block.PS.Str.
144.384]+
[VS.RAB.Block.PS.Str.32.64]
+[VS.RAB.Block.PS.Str.
64.144]+
[VS.RAB.BlockPS.BkgMor38
4]+[VS.RAB.BlockPS.Con-
vMor32]+
[VS.RAB.BlockPS.StrMor384
]+[VS.RAB.BlockPS.In-
tMor384]

VS.RAB.FailEstPs.P numb Measuremen -


ower.Cong er t of PS RAB
assignment
failure per
cell

VS.RAB.FailEstPs. numb Measuremen -


Code.Cong er t of PS RAB
assignment
failure per
cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 914


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.FailEstPs. numb Measuremen -


ULCE.Cong er t of PS RAB
assignment
failure per
cell

VS.RAB.FailEstPs. numb Measuremen -


DLCE.Cong er t of PS RAB
assignment
failure per
cell

VS.RAB.FailEstPS. numb Measuremen -


TNL er t of PS RAB
assignment
failure per
cell

VS.AMR.Ctrl.DL12. numb Measuremen -


2 er t of RB
Procedure
per cell

VS.RB.DLConvCS. numb Measuremen -


64 er t of RB
Procedure
per cell

VS.RB.ULInterPS. numb Measuremen -


64 er t of RB
Procedure
per cell

VS.RB.ULInterPS. numb Measuremen -


128 er t of RB
Procedure
per cell

VS.RB.ULInterPS. numb Measuremen -


144 er t of RB
Procedure
per cell

VS.RB.ULInterPS. numb Measuremen -


384 er t of RB
Procedure
per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 915


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RB.DLInterPS. numb Measuremen -


64 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


128 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


144 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


384 er t of RB
Procedure
per cell

VS.MAC.SRNCIub byte Traffic -


BytesPSInt.Tx Measuremen
t per cell

VS.MAC.SRNCIub byte Traffic -


BytesPSBkg.Tx Measuremen
t per cell

VS.LC.ULCreditUse none Measuremen -


d.CELL t related to
Algorithm
per cell

VS.LC.DLCreditUse none Measuremen -


d.CELL t related to
Algorithm
per cell

RRC.FailConnEstab. times RRC -


Cong connection
reject
measurement
per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 916


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.5.10 Traffic RNC TopN Report

Report Type
Simple Report

NE Type
RNC

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

AMR VS.AMR.RB.DL. numb Measuremen -


TopN 12.2 er t related to
AMR service

VS.RB.DLConvCS. numb Measuremen -


64.RNC er t of RB
Procedure
per RNC

VS.RB.ULInterPS. numb Measuremen -


64.RNC er t of RB
Procedure
per RNC

VS.RB.ULInterPS. numb Measuremen -


128.RNC er t of RB
Procedure
per RNC

VS.RB.ULInterPS. numb Measuremen -


144.RNC er t of RB
Procedure
per RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 917


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RB.ULInterPS. numb Measuremen -


384.RNC er t of RB
Procedure
per RNC

VS.RB.DLInterPS. numb Measuremen -


64.RNC er t of RB
Procedure
per RNC

VS.RB.DLInterPS. numb Measuremen -


128.RNC er t of RB
Procedure
per RNC

VS.RB.DLInterPS. numb Measuremen -


144.RNC er t of RB
Procedure
per RNC

VS.RB.DLInterPS. numb Measuremen -


384.RNC er t of RB
Procedure
per RNC

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.5.11 VIP Cell TopN Report

Report Type
Simple Report

NE Type
RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 918


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

VIP Cell VS.Call.Drop.Cell none Measuremen ([VS.RAB.Loss.CS.RF]+


t of RAB [VS.RAB.Loss.CS.Abnorm])+
release ([VS.RAB.Loss.PS.RF]+
triggered by [VS.RAB.Loss.PS.Abnorm])
UTRAN per
cell

VS.RRC.SuccConn % RRC [RRC.SuccConnEstab.sum]/


Estab.Cell.Rate connection [VS.RRC.AttConnEstab.Cell]
setup *{100.00}
measurement
per cell

VS.HHO.InterFreq. % Hard [VS.HHO.InterFreq.SuccOut]/


Out.Cell.Rate Handover [VS.HHO.InterFreq.AttOut]*
Measuremen {100.00}
t per cell

VS.MeanTCP dBm Cell TX and -


RX Power
Measuremen
t per cell

VS.MAC.SRNCIub byte Traffic -


BytesPSInt.Tx Measuremen
t per cell

VS.MAC.SRNCIub byte Traffic -


BytesPSBkg.Tx Measuremen
t per cell

VS.MaxRTWP dBm Cell TX and -


RX Power
Measuremen
t per cell

VS.MinRTWP dBm Cell TX and -


RX Power
Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 919


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.MaxTCP dBm Cell TX and -


RX Power
Measuremen
t per cell

VS.AMR.Ctrl.DL12. numb Measuremen -


2 er t of RB
Procedure
per cell

VS.RB.DLConvCS. numb Measuremen -


64 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


64 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


128 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


144 er t of RB
Procedure
per cell

VS.RB.DLInterPS. numb Measuremen -


384 er t of RB
Procedure
per cell

VS.RAB.SuccEstab % Measuremen [VS.RAB.SuccEstab.AMR]/


CS.AMR.Cell.Rate t of CS RAB [VS.RAB.AttEstab.AMR]*
assignment {100.00}
setup per cell

VS.RAB.SuccEstab % Measuremen [VS.RAB.SuccEstCS.Conv.


CS.Conv. t of CS RAB 64]/[VS.RAB.AttEstCS.Conv.
64.Cell.Rate assignment 64]*{100.00}
setup per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 920


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.SuccEstab % Measuremen ([VS.RAB.SuccEstabPS.Conv


PS.Cell.Rate t of PS RAB ]+[VS.RAB.SuccEstabPS.Str]
assignment +[VS.RAB.SuccEstabPS.In-
setup per cell ter]+
[VS.RAB.SuccEstabPS.Bkg])/
([VS.RAB.AttEstabPS.Conv]
+[VS.RAB.AttEstabPS.Str]+
[VS.RAB.AttEstabPS.Inter]+
[VS.RAB.AttEstabPS.Bkg])*
{100.00}

VS.SuccRBSetup.Ce % Measuremen [VS.SuccRBSetup]/


ll.Rate t of RB [VS.AttRBSetup]*{100.00}
Procedure
per cell

VS.IRATHO.SuccO % InterRAT [IRATHO.SuccOutCS]/


utCS.Cell.Rate Handover [IRATHO.AttOutCS]*
Measuremen {100.00}
t per cell

VS.CS.AMR.Call.D % Measuremen [VS.RAB.Loss.CS.AMR]/


rop.Cell.Rate t of RAB ([VS.RAB.Loss.CS.AMR]+
release [VS.RAB.Loss.CS.Norm.AM
triggered by R])*{100.00}
UTRAN per
cell

VS.CS.VP.Call.Dro % Measuremen [VS.RAB.Loss.CS.Conv64K]/


p.Cell.Rate t of RAB ([VS.RAB.Loss.CS.Conv64K]
release +[VS.Norm.Rel.CS.Conv.RB.
triggered by 64])*{100.00}
UTRAN per
cell

VS.PS.Call.Drop.Ce % Measuremen ([VS.RAB.Loss.PS.RF]+


ll.Rate t of RAB [VS.RAB.Loss.PS.Abnorm])/
release ([VS.RAB.Loss.PS.RF]+
triggered by [VS.RAB.Loss.PS.Abnorm]+
UTRAN per [VS.RAB.Loss.PS.Norm])*
cell {100.00}

VS.PCH.Utilization. % Traffic [VS.MAC.CRNCIubBytesPC


Cell.Rate Measuremen H.Tx]/
t per cell ([VS.CRNC.IUB.PCH.Band-
width]*{GP}*{60})*{100.00}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 921


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.FACH.Utilizatio % Traffic [VS.MAC.CRNCIubBytesFA


n.Cell.Rate Measuremen CH.Tx]/
t per cell ([VS.CRNC.IUB.FACH.Band
width]*{GP}*{60})*{100.00}

VS.RACH.Utilizatio % Traffic [VS.MAC.CRNCIubBytesRA


n.Cell.Rate Measuremen CH.Rx]/
t per cell ([VS.CRNC.IUB.RACH.Band
width]*{GP}*{60})*{100.00}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.6 RNC Monthly Report

21.6.1 CDR Report

Report Type
Simple Report

NE Type
RNC

Object Type
RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 922


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

CDR VS.RAB.SucEstCS numb Measuremen -


Report Conv0.32.RNC er t of CS RAB
assignment
setup per
RNC

VS.RAB.Loss.CS.A numb Measuremen -


MR.RNC er t of RAB
release
triggered by
UTRAN per
RNC

VS.AMR.Call.Drop. % Measuremen [VS.RAB.Loss.CS.AMR.RNC


RNC.Rate t of RAB ]/
release [VS.RAB.SucEstCSConv0.32.
triggered by RNC]*{100.00}
UTRAN per
RNC

VS.RAB.SucEstCS numb Measuremen -


Conv32.64.RNC er t of CS RAB
assignment
setup per
RNC

VS.RAB.Loss.CS.C numb Measuremen -


onv64K.RNC er t of RAB
release
triggered by
UTRAN per
RNC

VS.VP.Call.Drop.R % Measuremen [VS.RAB.Loss.CS.Conv64K.


NC.Rate t of RAB RNC]/
release [VS.RAB.SucEstCSConv32.6
triggered by 4.RNC]*{100.00}
UTRAN per
RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 923


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.SuccEstPS. none Measuremen ([RAB.SuccEstabPSNoQueui


RNC t of PS RAB ng.Bgrd]+
assignment [RAB.SuccEstabPSQueuing.B
setup per grd])+
RNC ([RAB.SuccEstabPSNoQueui
ng.Conv]+
[RAB.SuccEstabPSQueuing.C
onv])+
([RAB.SuccEstabPSNoQueui
ng.Intact]+
[RAB.SuccEstabPSQueuing.I
ntact])+
([RAB.SuccEstabPSQueuing.
Strm]+
[RAB.SuccEstabPSNoQueuin
g.Strm])

VS.PS.Call.Drop.R none Measuremen [VS.RAB.Loss.PS.RF.RNC]+


NC t of RAB [VS.RAB.Loss.PS.Abnorm.R
release NC]
triggered by
UTRAN per
RNC

VS.PS.Call.Drop.R % Measuremen (([VS.RAB.Loss.PS.RF.RNC]


NC.Rate t of RAB +
release [VS.RAB.Loss.PS.Abnorm.R
triggered by NC]))/
UTRAN per (([RAB.SuccEstabPSNoQueui
RNC ng.Bgrd]+
[RAB.SuccEstabPSQueuing.B
grd])+
([RAB.SuccEstabPSNoQueui
ng.Conv]+
[RAB.SuccEstabPSQueuing.C
onv])+
([RAB.SuccEstabPSNoQueui
ng.Intact]+
[RAB.SuccEstabPSQueuing.I
ntact])+
([RAB.SuccEstabPSQueuing.
Strm]+
[RAB.SuccEstabPSNoQueuin
g.Strm]))*{100.00}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 924


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.6.2 HO Report

Report Type
Simple Report

NE Type
RNC

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

HO VS.SHO.Att.RNC times Soft -


Report Handover
Measuremen
t per RNC

VS.SHO.Succ times Soft -


Handover
Measuremen
t per RNC

VS.SHO.Succ.Rate % Soft [VS.SHO.Succ]/


Handover [VS.SHO.Att.RNC]*{100.00}
Measuremen
t per RNC

VS.HHO.InterFreq. times Hard -


Att.RNC Handover
Measuremen
t per RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 925


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.HHO.InterFreq.S times Hard -


ucc.RNC Handover
Measuremen
t per RNC

VS.InterFreq.HHO.S % Hard [VS.HHO.InterFreq.Succ.RN


ucc.RNC.Rate Handover C]/
Measuremen [VS.HHO.InterFreq.Att.RNC]
t per RNC *{100.00}

VS.IRATHO.AttCS times Measuremen -


Out.RNC t related to
CS IRA
handover per
RNC

VS.IRATHO.SuccC times Measuremen -


SOut.RNC t related to
CS IRA
handover per
RNC

VS.IRATHO.SuccC % Measuremen [VS.IRATHO.SuccCSOut.RN


SOut.RNC.Rate t related to C]/
CS IRA [VS.IRATHO.AttCSOut.RNC
handover per ]*{100.00}
RNC

VS.SRELOC.AttPre times Measuremen -


p.IRHOCS t related to
CS IRA
handover per
RNC

VS.SRELOC.SuccPr times Measuremen -


ep.IRHOCS t related to
CS IRA
handover per
RNC

VS.SRELOC.SuccPr % Measuremen [VS.SRELOC.SuccPrep.IR-


ep.IRHOCS.Rate t related to HOCS]/
CS IRA [VS.SRELOC.AttPrep.IR-
handover per HOCS]*{100.00}
RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 926


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.IRATHO.AttPS times Measuremen -


OutUTRAN.RNC t related to PS
IRA
handover per
RNC

VS.IRATHO.SuccP times Measuremen -


SOutUTRAN.RNC t related to PS
IRA
handover per
RNC

VS.IRATHO.SuccP % Measuremen [VS.IRATHO.SuccPSOutUT


SOutUTRAN.RNC. t related to PS RAN.RNC]/
Rate IRA [VS.IRATHO.AttPSOutUTR
handover per AN.RNC]*{100.00}
RNC

VS.IRATHO.EvalP times Measuremen -


SOutUTRAN.RNC t related to PS
IRA
handover per
RNC

VS.IRATHO.SuccPr % Measuremen [VS.IRATHO.AttPSOutUTR


epPSOutUTRAN.Ra t related to PS AN.RNC]/
te IRA [VS.IRATHO.EvalPSOutUTR
handover per AN.RNC]*{100.00}
RNC

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.6.3 HSDPA KPI Monthly Report

Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 927


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

NE Type
RNC

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

HSDPA VS.HSDPA.MeanC none HSDPA [VS.HSDPA.MeanChThrough


Traffic hThroughput.Total- Measuremen put.TotalBytes]/({1024}*
MBytes t per cell {1024})

VS.HSDPA.UE.Mea numb HSDPA -


n.Cell er Measuremen
t per cell

VS.HSDPA.MeanC none HSDPA ([VS.HSDPA.MeanChThroug


hThroughput.To- Measuremen hput.TotalBytes]*{8.0}/
talMBps t per cell ({1024.0}*{1024.0}))/({GP}*
{60})

HSDPA VS.HSDPA.RAB.Su % HSDPA [VS.HSDPA.RAB.SuccEs-


Access ccEstab.Rate Measuremen tab]/[VS.HSDPA.RAB.AttEs-
t per cell tab]*{100.00}

VS.HSDPA.RAB.Su times HSDPA -


ccEstab Measuremen
t per cell

VS.HSDPA.RAB.At times HSDPA -


tEstab Measuremen
t per cell

HSDPA VS.HSDPA.ServCel % HSDPA [VS.HSDPA.SHO.CellChg.Su


HO lChg.Succ.Rate Measuremen ccOut]/
t per cell [VS.HSDPA.SHO.CellChg.At
tOut]*{100.00}

VS.HSDPA.SHO.Ce times HSDPA -


llChg.SuccOut Measuremen
t per cell

VS.HSDPA.SHO.Ce times HSDPA -


llChg.AttOut Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 928


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.HSDPA.HHO.In % HSDPA [VS.HSDPA.HHO.SuccOu-


traFreq.NoChR.Succ Measuremen tIntraFreq]/
.Rate t per cell [VS.HSDPA.HHO.AttOutIn-
traFreq]*{100.00}

VS.HSDPA.HHO.S times HSDPA -


uccOutIntraFreq Measuremen
t per cell

VS.HSDPA.HHO.At times HSDPA -


tOutIntraFreq Measuremen
t per cell

VS.HSDPA.HHO.In % HSDPA [VS.HSDPA.HHO.SuccOu-


terFreq.NoChR.Succ Measuremen tInterFreq]/
.Rate t per cell [VS.HSDPA.HHO.AttOutIn-
terFreq]*{100.00}

VS.HSDPA.HHO.S times HSDPA -


uccOutInterFreq Measuremen
t per cell

VS.HSDPA.HHO.At times HSDPA -


tOutInterFreq Measuremen
t per cell

VS.HSDPA.ChR.HS % HSDPA [VS.HSDPA.ChR.HSDSCHto


DSCHtoDCH.Succ. Measuremen DCH]/
Rate t per cell [VS.HSDPA.ChR.HSDSCHto
DCH.Att]*{100.00}

VS.HSDPA.ChR.HS times HSDPA -


DSCHtoDCH Measuremen
t per cell

VS.HSDPA.ChR.HS times HSDPA -


DSCHtoDCH.Att Measuremen
t per cell

VS.HSDPA.ChR.D % HSDPA [VS.HSDPA.ChR.DCHtoHSD


CHtoHSDSCH.Succ Measuremen SCH]/
.Rate t per cell [VS.HSDPA.ChR.DCHtoHSD
SCH.Att]*{100.00}

VS.HSDPA.ChR.D times HSDPA -


CHtoHSDSCH Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 929


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.HSDPA.ChR.D times HSDPA -


CHtoHSDSCH.Att Measuremen
t per cell

HSDPA VS.HSDPA.RAB.A % HSDPA ([VS.HSDPA.RAB.Loss.Abn


CDR bnormRel.Rate Measuremen orm.NonRF]+
t per cell [VS.HSDPA.RAB.Loss.RF])/
([VS.HSDPA.RAB.Loss.In-
Activity]+
[VS.HSDPA.RAB.Loss.Abno
rm.NonRF]+
[VS.HSDPA.RAB.Loss.RF]+
[VS.HSDPA.RAB.Loss.Norm
]+
[VS.HSDPA.ChR.HSDSCHto
DCH]+
[VS.HSDPA.ChR.HSDSCHto
FACH]+
[VS.HSDPA.HHO.H2D.Suc-
cOutIntraFreq]+
[VS.HSDPA.HHO.H2D.Suc-
cOutInterFreq])*{100.00}

VS.HSDPA.RAB.A none HSDPA [VS.HSDPA.RAB.Loss.Abno


bnormRel Measuremen rm.NonRF]+
t per cell [VS.HSDPA.RAB.Loss.RF]

VS.HSDPA.RAB.Re none HSDPA [VS.HSDPA.RAB.Loss.InAc-


l Measuremen tivity]+
t per cell [VS.HSDPA.RAB.Loss.Abno
rm.NonRF]+
[VS.HSDPA.RAB.Loss.RF]+
[VS.HSDPA.RAB.Loss.Norm
]+
[VS.HSDPA.ChR.HSDSCHto
DCH]+
[VS.HSDPA.ChR.HSDSCHto
FACH]+
[VS.HSDPA.HHO.H2D.Suc-
cOutIntraFreq]+
[VS.HSDPA.HHO.H2D.Suc-
cOutInterFreq]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 930


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.6.4 HSUPA KPI Monthly Report

Report Type
Simple Report

NE Type
RNC

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

HSUPA VS.HSUPA.RAB.Su % HSUPA [VS.HSUPA.RAB.SuccEs-


Access ccEstab.Rate Measuremen tab]/[VS.HSUPA.RAB.AttEs-
t per cell tab]*{100.00}

VS.HSUPA.RAB.Su numb HSUPA -


ccEstab er Measuremen
t per cell

VS.HSUPA.RAB.At numb HSUPA -


tEstab er Measuremen
t per cell

HSUPA VS.HSUPA.EDCH. % HSUPA [VS.HSUPA.EDCH.SHO.Suc


HO SHO.Succ.Ratio Measuremen c]/
t per cell [VS.HSUPA.EDCH.SHO.Att]
*{100.00}

VS.HSUPA.EDCH. times HSUPA -


SHO.Succ Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 931


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.HSUPA.EDCH. times HSUPA -


SHO.Att Measuremen
t per cell

VS.HSUPA.SHO.Se % HSUPA [VS.HSUPA.SHO.ServCellCh


rvCellChg.Succ.Ra- Measuremen g.Succ]/
tio t per cell [VS.HSUPA.SHO.ServCellCh
g.Att]*{100.00}

VS.HSUPA.SHO.Se times HSUPA -


rvCellChg.Succ Measuremen
t per cell

VS.HSUPA.SHO.Se times HSUPA -


rvCellChg.Att Measuremen
t per cell

VS.HSUPA.HHO.In % HSUPA [VS.HSUPA.HHO.InterFreq.


terFreq.NoChR.Succ Measuremen NoChR.Succ]/
.Ratio t per cell [VS.HSUPA.HHO.InterFreq.
NoChR.Att]*{100.00}

VS.HSUPA.HHO.In times HSUPA -


terFreq.NoChR.Succ Measuremen
t per cell

VS.HSUPA.HHO.In times HSUPA -


terFreq.NoChR.Att Measuremen
t per cell

HSUPA VS.HSUPA.RAB.A % HSUPA ([VS.HSUPA.RAB.Loss.Ab-


CDR bnormRel.Rate Measuremen norm])/
t per cell ([VS.HSUPA.RAB.Loss.Ab-
norm]+
[VS.HSUPA.RAB.Loss.Norm
]+
[VS.HSUPA.ChR.IntraCell.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.IntraFreq.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.InterFreq.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.EDCHtoFA
CH.Succ])*{100.00}

VS.HSUPA.RAB.A none HSUPA [VS.HSUPA.RAB.Loss.Ab-


bnormRel Measuremen norm]
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 932


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.HSUPA.RAB.Re none HSUPA [VS.HSUPA.RAB.Loss.Ab-


lease Measuremen norm]+
t per cell [VS.HSUPA.RAB.Loss.Norm
]+
[VS.HSUPA.ChR.IntraCell.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.IntraFreq.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.InterFreq.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.EDCHtoFA
CH.Succ]

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.6.5 PAGE Report

Report Type
Simple Report

NE Type
RNC

Object Type
RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 933


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

PAGE VS.RANAP.Paging. times Measuremen -


Report Att.IdleUE t related to
Paging per
RNC

VS.RANAP.Paging. times Measuremen -


Succ.IdleUE t related to
Paging per
RNC

VS.RANAP.Paging. % Measuremen [VS.RANAP.Paging.Succ.Idle


Succ.IdleUE.Rate t related to UE]/
Paging per [VS.RANAP.Paging.Att.IdleU
RNC E]*{100.00}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.6.6 RAB Report

Report Type
Simple Report

NE Type
RNC

Object Type
RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 934


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

RAB VS.RAB.AttEstCSC numb Measuremen -


Report onv0.32.RNC er t of CS RAB
assignment
setup per
RNC

VS.RAB.SucEstCS numb Measuremen -


Conv0.32.RNC er t of CS RAB
assignment
setup per
RNC

RAB.SuccEstabCSC % Measuremen [VS.RAB.SucEstCSConv0.32.


onv0.32.RNC.Rate t of CS RAB RNC]/
assignment [VS.RAB.AttEstCSConv0.32.
setup per RNC]*{100.00}
RNC

VS.RAB.AttEstCSC numb Measuremen -


onv32.64.RNC er t of CS RAB
assignment
setup per
RNC

VS.RAB.SucEstCS numb Measuremen -


Conv32.64.RNC er t of CS RAB
assignment
setup per
RNC

RAB.SuccEstabCSC % Measuremen [VS.RAB.SucEstCSConv32.6


onv32.64.RNC.Rate t of CS RAB 4.RNC]/
assignment [VS.RAB.AttEstCSConv32.64
setup per .RNC]*{100.00}
RNC

RAB.AttEstabPS.In- numb Measuremen -


tact er t of PS RAB
assignment
setup per
RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 935


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.SucEstPSI none Measuremen [VS.RAB.SucEstPSInt0.32.R


nt.RNC t of PS RAB NC]+
assignment [VS.RAB.SucEstPSInt32.64.R
setup per NC]+
RNC [VS.RAB.SucEstPSInt64.144.
RNC]+
[VS.RAB.SucEstPSInt144384
.RNC]+
[VS.RAB.SucEstPSIntMor38
4.RNC]

VS.RAB.SucEstPSI % Measuremen ([VS.RAB.SucEstPSInt0.32.R


nt.RNC.Rate t of PS RAB NC]+
assignment [VS.RAB.SucEstPSInt32.64.R
setup per NC]+
RNC [VS.RAB.SucEstPSInt64.144.
RNC]+
[VS.RAB.SucEstPSInt144384
.RNC]+
[VS.RAB.SucEstPSIntMor38
4.RNC])/
[RAB.AttEstabPS.Intact]*
{100.00}

RAB.AttEstabPS.Bg numb Measuremen -


rd er t of PS RAB
assignment
setup per
RNC

VS.RAB.SucEstPSB none Measuremen [VS.RAB.SucEstPSBkg0.32.


kg.RNC t of PS RAB RNC]+
assignment [VS.RAB.SucEstPSBkg32.64.
setup per RNC]+
RNC [VS.RAB.SucEstPSBkg64.14
4.RNC]+
[VS.RAB.SucEstPSBkg14438
4.RNC]+
[VS.RAB.SucEstPSBkgMor3
84.RNC]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 936


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.SucEstPSB % Measuremen ([VS.RAB.SucEstPSBkg0.32.


kg.RNC.Rate t of PS RAB RNC]+
assignment [VS.RAB.SucEstPSBkg32.64.
setup per RNC]+
RNC [VS.RAB.SucEstPSBkg64.14
4.RNC]+
[VS.RAB.SucEstPSBkg14438
4.RNC]+
[VS.RAB.SucEstPSBkgMor3
84.RNC])/
[RAB.AttEstabPS.Bgrd]*
{100.00}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.6.7 RCC Report

Report Type
Simple Report

NE Type
RNC

Object Type
RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 937


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

RCC VS.RRC.AttConnEs none RRC [VS.RRC.AttConnEstab.CellR


Report tab.Other connection es]+
setup [VS.RRC.AttConnEstab.Reg]
measurement +[VS.RRC.AttConnEstab.De-
per RNC tach]

VS.RRC.SuccConn none RRC [VS.RRC.SuccConnEstab.Cell


Estab.Other connection Res]+
setup [VS.RRC.SuccConnEstab.Reg
measurement ]+
per RNC [VS.RRC.SuccConnEstab.De-
tach]

VS.RRC.SuccConn % RRC ([VS.RRC.SuccConnEstab.E


Estab.Rate.Other connection mg]+
setup [VS.RRC.SuccConnEstab.Cell
measurement Res]+
per RNC [VS.RRC.SuccConnEstab.Reg
]+
[VS.RRC.SuccConnEstab.De-
tach]+
[VS.RRC.SuccConnEstab.Un-
known])/
([VS.RRC.AttConnEstab.Emg
]+
[VS.RRC.AttConnEstab.CellR
es]+
[VS.RRC.AttConnEstab.Reg]
+[VS.RRC.AttConnEstab.De-
tach]+
[VS.RRC.AttConnEstab.Un-
known])*{100.00}

VS.RRC.AttConnEs none RRC [VS.RRC.AttConnEstab.Org-


tab.Conv connection Conv]+
setup [VS.RRC.AttConnEstab.Trm
measurement Conv]
per RNC

VS.RRC.SuccConn none RRC [VS.RRC.SuccConnEstab.Org


Estab.Conv connection Conv]+
setup [VS.RRC.SuccConnEstab.Tr
measurement mConv]
per RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 938


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RRC.SuccConn % RRC ([VS.RRC.SuccConnEstab.Or


Estab.Conv.Rate connection gConv]+
setup [VS.RRC.SuccConnEstab.Tr
measurement mConv])/
per RNC ([VS.RRC.AttConnEstab.Org-
Conv]+
[VS.RRC.AttConnEstab.Trm
Conv])*{100.00}

VS.RRC.AttConnEs none RRC [VS.RRC.AttConnEstab.OrgB


tab.Bkg connection kg]+
setup [VS.RRC.AttConnEstab.Trm
measurement Bkg]
per RNC

VS.RRC.SuccConn none RRC [VS.RRC.SuccConnEstab.Org


Estab.Bkg connection Bkg]+
setup [VS.RRC.SuccConnEstab.Tr
measurement mBkg]
per RNC

VS.RRC.SuccConn % RRC ([VS.RRC.SuccConnEstab.Or


Estab.Bkg.Rate connection gBkg]+
setup [VS.RRC.SuccConnEstab.Tr
measurement mBkg])/
per RNC ([VS.RRC.AttConnEstab.Org
Bkg]+
[VS.RRC.AttConnEstab.Trm
Bkg])*{100.00}

VS.RRC.AttConnEs none RRC [VS.RRC.AttConnEstab.Or-


tab.Int connection gInt]+
setup [VS.RRC.AttConnEstab.TrmI
measurement nt]
per RNC

VS.RRC.SuccConn none RRC [VS.RRC.SuccConnEstab.Or-


Estab.Int connection gInt]+
setup [VS.RRC.SuccConnEstab.Tr
measurement mInt]
per RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 939


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RRC.SuccConn % RRC ([VS.RRC.SuccConnEstab.Or


Estab.Int.Rate connection gInt]+
setup [VS.RRC.SuccConnEstab.Tr
measurement mInt])/
per RNC ([VS.RRC.AttConnEstab.Or-
gInt]+
[VS.RRC.AttConnEstab.TrmI
nt])*{100.00}

VS.RRC.AttConnEs none RRC [VS.RRC.AttConnEstab.Org-


tab.Org connection Conv]+
setup [VS.RRC.AttConnEstab.OrgS
measurement tr]+
per RNC [VS.RRC.AttConnEstab.Or-
gInt]+
[VS.RRC.AttConnEstab.OrgB
kg]+
[VS.RRC.AttConnEstab.Org-
Subs]

VS.RRC.SuccConn none RRC [VS.RRC.SuccConnEstab.Org


Estab.Org connection Conv]+
setup [VS.RRC.SuccConnEstab.Org
measurement Str]+
per RNC [VS.RRC.SuccConnEstab.Or-
gInt]+
[VS.RRC.SuccConnEstab.Org
Bkg]+
[VS.RRC.SuccConnEstab.Org
Subs]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 940


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RRC.SuccConn % RRC ([VS.RRC.SuccConnEstab.Or


Estab.Org.Rate connection gConv]+
setup [VS.RRC.SuccConnEstab.Org
measurement Str]+
per RNC [VS.RRC.SuccConnEstab.Or-
gInt]+
[VS.RRC.SuccConnEstab.Org
Bkg]+
[VS.RRC.SuccConnEstab.Org
Subs])/
([VS.RRC.AttConnEstab.Org-
Conv]+
[VS.RRC.AttConnEstab.OrgS
tr]+
[VS.RRC.AttConnEstab.Or-
gInt]+
[VS.RRC.AttConnEstab.OrgB
kg]+
[VS.RRC.AttConnEstab.Org-
Subs])*{100.00}

VS.RRC.AttConnEs none RRC [VS.RRC.AttConnEstab.Trm


tab.Trm connection Conv]+
setup [VS.RRC.AttConnEstab.TrmS
measurement tr]+
per RNC [VS.RRC.AttConnEstab.TrmI
nt]+
[VS.RRC.AttConnEstab.Trm
Bkg]

VS.RRC.SuccConn none RRC [VS.RRC.SuccConnEstab.Tr


Estab.Trm connection mConv]+
setup [VS.RRC.SuccConnEstab.Tr
measurement mStr]+
per RNC [VS.RRC.SuccConnEstab.Tr
mInt]+
[VS.RRC.SuccConnEstab.Tr
mBkg]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 941


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RRC.SuccConn % RRC ([VS.RRC.SuccConnEstab.Tr


Estab.Trm.Rate connection mConv]+
setup [VS.RRC.SuccConnEstab.Tr
measurement mStr]+
per RNC [VS.RRC.SuccConnEstab.Tr
mInt]+
[VS.RRC.SuccConnEstab.Tr
mBkg])/
([VS.RRC.AttConnEstab.Trm
Conv]+
[VS.RRC.AttConnEstab.TrmS
tr]+
[VS.RRC.AttConnEstab.TrmI
nt]+
[VS.RRC.AttConnEstab.Trm
Bkg])*{100.00}

VS.RRC.AttConnEs times RRC -


tab.Reg connection
setup
measurement
per RNC

VS.RRC.SuccConn times RRC -


Estab.Reg connection
setup
measurement
per RNC

VS.RRC.SuccConn % RRC [VS.RRC.SuccConnEstab.Reg


Estab.Reg.Rate connection ]/
setup [VS.RRC.AttConnEstab.Reg]
measurement *{100.00}
per RNC

VS.RRC.AttConnEs times RRC -


tab.CellRes connection
setup
measurement
per RNC

VS.RRC.SuccConn times RRC -


Estab.CellRes connection
setup
measurement
per RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 942


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RRC.SuccConn % RRC [VS.RRC.SuccConnEstab.Cell


Estab.CellRes.Rate connection Res]/
setup [VS.RRC.AttConnEstab.CellR
measurement es]*{100.00}
per RNC

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.6.8 RNC All Service Monthly Report

Report Type
Simple Report

NE Type
RNC

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Traffic VS.AMR.RB.DL. numb Measuremen -


12.2 er t related to
AMR service

VS.RB.DLConvCS. numb Measuremen -


64.RNC er t of RB
Procedure
per RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 943


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.CSLoad.Erlang. none Traffic -


Equiv.RNC Measuremen
t per RNC

VS.R99PSLoad.UL kbit/s Traffic -


Thruput.RNC Measuremen
t per RNC

VS.R99PSLoad.DL kbit/s Traffic -


Thruput.RNC Measuremen
t per RNC

VS.HSUPAPSLoad. kbit/s Traffic -


ULThruput.RNC Measuremen
t per RNC

VS.HSDPAPSLoad. kbit/s Traffic -


DLThruput.RNC Measuremen
t per RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 944


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Access VS.RRC.SuccConn % RRC ([RRC.SuccConnEstab.Og-


Estab.Service.Cell.R connection ConvCall]+
ate setup [RRC.SuccConnEstab.OrgStr-
measurement Call]+
per cell [RRC.SuccConnEstab.OrgItr-
Call]+
[RRC.SuccConnEstab.OrgBk
gCall]+
[RRC.SuccConnEstab.Org-
SubCall]+
[RRC.SuccConnEstab.TmCon
vCall]+
[RRC.SuccConnEstab.TmStr
Call]+
[RRC.SuccConnEstab.TmItr-
Call]+
[RRC.SuccConnEstab.TmBkg
Call]+
[RRC.SuccConnEstab.Emg-
Call]+
[RRC.SuccConnEstab.Un-
kown]+
[RRC.SuccConnEstab.OgHhP
rSig]+
[RRC.SuccConnEstab.OgLwP
rSig]+
[RRC.SuccConnEstab.CallRe-
Est]+
[RRC.SuccConnEstab.TmHhP
rSig]+
[RRC.SuccConnEstab.TmLw
PrSig])/
([RRC.AttConnEstab.Org-
ConvCall]+
[RRC.AttConnEstab.OrgStr-
Call]+
[RRC.AttConnEstab.OrgInter-
Call]+
[RRC.AttConnEstab.OrgBkg-
Call]+
[RRC.AttConnEstab.OgSub-
Call]+
[RRC.AttConnEstab.TmConv
Call]+
[RRC.AttConnEstab.TmStrCa
ll]+
[RRC.AttConnEstab.TmInter-

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 945


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Call]+
[RRC.AttConnEstab.TmBkgC
all]+
[RRC.AttConnEstab.Emg-
Call]+
[RRC.AttConnEstab.Un-
known]+
[RRC.AttConnEstab.OgHhPr-
Sig]+
[RRC.AttConnEstab.OgLwPr-
Sig]+
[RRC.AttConnEstab.CallRe-
Est]+
[RRC.AttConnEstab.TmHhPr
Sig]+
[RRC.AttConnEstab.TmLwPr
Sig])*{100.00}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 946


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RRC.SuccConn none RRC [RRC.SuccConnEstab.Og-


Estab.Service.Cell connection ConvCall]+
setup [RRC.SuccConnEstab.OrgStr-
measurement Call]+
per cell [RRC.SuccConnEstab.OrgItr-
Call]+
[RRC.SuccConnEstab.OrgBk
gCall]+
[RRC.SuccConnEstab.Org-
SubCall]+
[RRC.SuccConnEstab.TmCon
vCall]+
[RRC.SuccConnEstab.TmStr
Call]+
[RRC.SuccConnEstab.TmItr-
Call]+
[RRC.SuccConnEstab.TmBkg
Call]+
[RRC.SuccConnEstab.Emg-
Call]+
[RRC.SuccConnEstab.Un-
kown]+
[RRC.SuccConnEstab.OgHhP
rSig]+
[RRC.SuccConnEstab.OgLwP
rSig]+
[RRC.SuccConnEstab.CallRe-
Est]+
[RRC.SuccConnEstab.TmHhP
rSig]+
[RRC.SuccConnEstab.TmLw
PrSig]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 947


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RRC.AttConnEs none RRC [RRC.AttConnEstab.Org-


tab.Service.Cell connection ConvCall]+
setup [RRC.AttConnEstab.OrgStr-
measurement Call]+
per cell [RRC.AttConnEstab.OrgInter-
Call]+
[RRC.AttConnEstab.OrgBkg-
Call]+
[RRC.AttConnEstab.OgSub-
Call]+
[RRC.AttConnEstab.TmConv
Call]+
[RRC.AttConnEstab.TmStrCa
ll]+
[RRC.AttConnEstab.TmInter-
Call]+
[RRC.AttConnEstab.TmBkgC
all]+
[RRC.AttConnEstab.Emg-
Call]+
[RRC.AttConnEstab.Un-
known]+
[RRC.AttConnEstab.OgHhPr-
Sig]+
[RRC.AttConnEstab.OgLwPr-
Sig]+
[RRC.AttConnEstab.CallRe-
Est]+
[RRC.AttConnEstab.TmHhPr
Sig]+
[RRC.AttConnEstab.TmLwPr
Sig]

VS.RRC.SuccConn % RRC ([RRC.SuccConnEstab.IRAT-


Estab.Other.Cell.Rat connection CelRes]+
e setup [RRC.SuccConnEstab.IRATC
measurement CO]+
per cell [RRC.SuccConnEstab.Reg]+
[RRC.SuccConnEstab.De-
tach])/
([RRC.AttConnEstab.IRAT-
CelRes]+
[RRC.AttConnEstab.IRATC-
CO]+
[RRC.AttConnEstab.Reg]+
[RRC.AttConnEstab.Detach])
*{100.00}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 948


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RRC.SuccConn none RRC [RRC.SuccConnEstab.IRAT-


Estab.Other.Cell connection CelRes]+
setup [RRC.SuccConnEstab.IRATC
measurement CO]+
per cell [RRC.SuccConnEstab.Reg]+
[RRC.SuccConnEstab.Detach]

VS.RRC.AttConnEs none RRC [RRC.AttConnEstab.IRAT-


tab.Other.Cell connection CelRes]+
setup [RRC.AttConnEstab.IRATC-
measurement CO]+
per cell [RRC.AttConnEstab.Reg]+
[RRC.AttConnEstab.Detach]

VS.RAB.SuccEstab % Measuremen [VS.RAB.SuccEstab.AMR]/


CS.AMR.Cell.Rate t of CS RAB [VS.RAB.AttEstab.AMR]*
assignment {100.00}
setup per cell

VS.RAB.SuccEstab. numb Measuremen -


AMR er t of CS RAB
assignment
setup per cell

VS.RAB.AttEstab.A numb Measuremen -


MR er t of CS RAB
assignment
setup per cell

VS.RAB.SuccEstab % Measuremen [VS.RAB.SuccEstCS.Conv.


CS.Conv. t of CS RAB 64]/[VS.RAB.AttEstCS.Conv.
64.Cell.Rate assignment 64]*{100.00}
setup per cell

VS.RAB.SuccEstCS numb Measuremen -


.Conv.64 er t of CS RAB
assignment
setup per cell

VS.RAB.AttEstCS. numb Measuremen -


Conv.64 er t of CS RAB
assignment
setup per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 949


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.SuccEstab % Measuremen ([VS.RAB.SuccEstabPS.Conv


PS.Cell.Rate t of PS RAB ]+[VS.RAB.SuccEstabPS.Str]
assignment +[VS.RAB.SuccEstabPS.In-
setup per cell ter]+
[VS.RAB.SuccEstabPS.Bkg])/
([VS.RAB.AttEstabPS.Conv]
+[VS.RAB.AttEstabPS.Str]+
[VS.RAB.AttEstabPS.Inter]+
[VS.RAB.AttEstabPS.Bkg])*
{100.00}

VS.RAB.SuccEstPS. none Measuremen [VS.RAB.SuccEstabPS.Conv]


Cell t of PS RAB +[VS.RAB.SuccEstabPS.Str]+
assignment [VS.RAB.SuccEstabPS.Inter]
setup per cell +[VS.RAB.SuccEstabPS.Bkg]

VS.RAB.AttEstabPS numb Measuremen [VS.RAB.AttEstabPS.Conv]+


.Cell er t of PS RAB [VS.RAB.AttEstabPS.Str]+
assignment [VS.RAB.AttEstabPS.Inter]+
setup per cell [VS.RAB.AttEstabPS.Bkg]

HO VS.SHO.Factor.RL none Soft ([VS.SHO.AS.1]+


Handover [VS.SHO.AS.2Softer]*{2}+
Measuremen [VS.SHO.AS.2Soft]*{2}+
t per RNC [VS.SHO.AS.3Softer]*{3}+
[VS.SHO.AS.3Soft]*{3}+
[VS.SHO.AS.3Soft2Softer]*
{3}+[VS.SHO.AS.4]*{4}+
[VS.SHO.AS.5]*{5}+
[VS.SHO.AS.6]*{6})/
([VS.SHO.AS.1]+
[VS.SHO.AS.2Softer]+
[VS.SHO.AS.2Soft]+
[VS.SHO.AS.3Softer]+
[VS.SHO.AS.3Soft]+
[VS.SHO.AS.3Soft2Softer]+
[VS.SHO.AS.4]+
[VS.SHO.AS.5]+
[VS.SHO.AS.6])-{1}

VS.SHO.Succ.Rate % Soft [VS.SHO.Succ]/


Handover [VS.SHO.Att.RNC]*{100.00}
Measuremen
t per RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 950


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.SHO.Succ times Soft -


Handover
Measuremen
t per RNC

VS.SHO.Att.RNC times Soft -


Handover
Measuremen
t per RNC

VS.InterFreq.HHO.S % Hard [VS.HHO.InterFreq.Succ.RN


ucc.RNC.Rate Handover C]/
Measuremen [VS.HHO.InterFreq.Att.RNC]
t per RNC *{100.00}

VS.HHO.InterFreq.S times Hard -


ucc.RNC Handover
Measuremen
t per RNC

VS.HHO.InterFreq. times Hard -


Att.RNC Handover
Measuremen
t per RNC

VS.IRATHO.SuccC % Measuremen [VS.IRATHO.SuccCSOut.RN


SOut.RNC.Rate t related to C]/
CS IRA [VS.IRATHO.AttCSOut.RNC
handover per ]*{100.00}
RNC

VS.IRATHO.SuccC times Measuremen -


SOut.RNC t related to
CS IRA
handover per
RNC

VS.IRATHO.AttCS times Measuremen -


Out.RNC t related to
CS IRA
handover per
RNC

VS.IRATHO.SuccP % Measuremen [VS.IRATHO.SuccPSOutUT


SOutUTRAN.RNC. t related to PS RAN.RNC]/
Rate IRA [VS.IRATHO.AttPSOutUTR
handover per AN.RNC]*{100.00}
RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 951


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.IRATHO.SuccP times Measuremen -


SOutUTRAN.RNC t related to PS
IRA
handover per
RNC

VS.IRATHO.AttPS times Measuremen -


OutUTRAN.RNC t related to PS
IRA
handover per
RNC

CDR VS.Abnorm.Rel.CS. times Measuremen -


AMR.IurLink t related to
SRNC in Iur
interface

VS.Rel.CS.AMR.Iur none Measuremen [VS.Norm.Rel.CS.AMR.Iur-


Link t related to Link]+
SRNC in Iur [VS.Abnorm.Rel.CS.AMR.Iur
interface Link]

VS.RAB.Loss.CS.A numb Measuremen -


MR er t of RAB
release
triggered by
UTRAN per
cell

VS.CS.AMR.Re- none Measuremen [VS.RAB.Loss.CS.AMR]+


lease t of RAB [VS.RAB.Loss.CS.Norm.AM
release R]
triggered by
UTRAN per
cell

VS.Abnorm.Rel.CS. times Measuremen -


Conv.RB.64.IurLink t related to
SRNC in Iur
interface

VS.Rel.CS.VP.Iur- none Measuremen [VS.Norm.Rel.CS.Conv.RB.


Link t related to 64.IurLink]+
SRNC in Iur [VS.Abnorm.Rel.CS.Conv.RB
interface .64.IurLink]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 952


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.Loss.CS.C numb Measuremen -


onv64K er t of RAB
release
triggered by
UTRAN per
cell

VS.CS.VP.Release none Measuremen [VS.RAB.Loss.CS.Conv64K]


t of RAB +[VS.Norm.Rel.CS.Conv.RB.
release 64]
triggered by
UTRAN per
cell

VS.Abnorm.Rel.PS.I none Measuremen [VS.Abnorm.Rel.PS.BE.RB.


urLink t related to 0.32.IurLink]+
SRNC in Iur [VS.Abnorm.Rel.PS.BE.RB.
interface 32.64.IurLink]+
[VS.Abnorm.Rel.PS.BE.RB.
64.144.IurLink]+
[VS.Abnorm.Rel.PS.BE.RB.
144.384.IurLink]+
[VS.Abnorm.Rel.PS.CCH.Iur-
Link]

VS.Rel.PS.IurLink none Measuremen [VS.Norm.Rel.PS.BE.RB.


t related to 0.32.IurLink]+
SRNC in Iur [VS.Norm.Rel.PS.BE.RB.
interface 32.64.IurLink]+
[VS.Norm.Rel.PS.BE.RB.
64.144.IurLink]+
[VS.Norm.Rel.PS.BE.RB.
144.384.IurLink]+
[VS.Norm.Rel.PS.CCH.Iur-
Link]+
[VS.Abnorm.Rel.PS.BE.RB.
0.32.IurLink]+
[VS.Abnorm.Rel.PS.BE.RB.
32.64.IurLink]+
[VS.Abnorm.Rel.PS.BE.RB.
64.144.IurLink]+
[VS.Abnorm.Rel.PS.BE.RB.
144.384.IurLink]+
[VS.Abnorm.Rel.PS.CCH.Iur-
Link]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 953


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.PS.Call.Drop.Ce numb Measuremen [VS.RAB.Loss.PS.RF]+


ll er t of RAB [VS.RAB.Loss.PS.Abnorm]
release
triggered by
UTRAN per
cell

VS.PS.RAB.Release none Measuremen [VS.RAB.Loss.PS.RF]+


t of RAB [VS.RAB.Loss.PS.Abnorm]+
release [VS.RAB.Loss.PS.Norm]
triggered by
UTRAN per
cell

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.6.9 Traffic Monthly BH Report

Report Type
Simple Report

NE Type
RNC

Object Type
RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 954


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Traffic VS.AMR.RB.DL. numb Measuremen -


Monthly 12.2 er t related to
BH AMR service
Report
VS.RB.DLConvCS. numb Measuremen -
64.RNC er t of RB
Procedure
per RNC

VS.RB.DLInterPS. numb Measuremen -


64.RNC er t of RB
Procedure
per RNC

VS.RB.DLInterPS. numb Measuremen -


128.RNC er t of RB
Procedure
per RNC

VS.RB.DLInterPS. numb Measuremen -


144.RNC er t of RB
Procedure
per RNC

VS.RB.DLInterPS. numb Measuremen -


384.RNC er t of RB
Procedure
per RNC

VS.RB.DLBkgPS. numb Measuremen -


64.RNC er t of RB
Procedure
per RNC

VS.RB.DLBkgPS. numb Measuremen -


128.RNC er t of RB
Procedure
per RNC

VS.RB.DLBkgPS. numb Measuremen -


144.RNC er t of RB
Procedure
per RNC

VS.RB.DLBkgPS. numb Measuremen -


384.RNC er t of RB
Procedure
per RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 955


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.6.10 Traffic Report

Report Type
Simple Report

NE Type
RNC

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Traffic VS.AMR.RB.DL. numb Measuremen -


Report 12.2 er t related to
AMR service

VS.RB.DLConvCS. numb Measuremen -


64.RNC er t of RB
Procedure
per RNC

VS.RB.DLInterPS. numb Measuremen -


64.RNC er t of RB
Procedure
per RNC

VS.RB.DLInterPS. numb Measuremen -


128.RNC er t of RB
Procedure
per RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 956


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RB.DLInterPS. numb Measuremen -


144.RNC er t of RB
Procedure
per RNC

VS.RB.DLInterPS. numb Measuremen -


384.RNC er t of RB
Procedure
per RNC

VS.RB.DLBkgPS. numb Measuremen -


64.RNC er t of RB
Procedure
per RNC

VS.RB.DLBkgPS. numb Measuremen -


128.RNC er t of RB
Procedure
per RNC

VS.RB.DLBkgPS. numb Measuremen -


144.RNC er t of RB
Procedure
per RNC

VS.RB.DLBkgPS. numb Measuremen -


384.RNC er t of RB
Procedure
per RNC

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.7 RNC Weekly Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 957


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

21.7.1 CDR Report

Report Type
Simple Report

NE Type
RNC

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

CDR RAB.SuccEstabCS none Measuremen ([RAB.SuccEstabCSNoQueui


t of CS RAB ng.Conv]+
assignment [RAB.SuccEstabCSQueuing.
setup per Conv])+
RNC ([RAB.SuccEstabCSNoQueui
ng.Strm]+
[RAB.SuccEstabCSQueuing.S
trm])

VS.CS.Call.Drop.R none Measuremen [VS.RAB.Loss.CS.Abnorm.R


NC t of RAB NC]+
release [VS.RAB.Loss.CS.RF.RNC]
triggered by
UTRAN per
RNC

VS.CS.Call.Drop.R % Measuremen ([VS.RAB.Loss.CS.Abnorm.R


NC.Rate t of RAB NC]+
release [VS.RAB.Loss.CS.RF.RNC])/
triggered by (([RAB.SuccEstabCSNoQueui
UTRAN per ng.Conv]+
RNC [RAB.SuccEstabCSQueuing.
Conv])+
([RAB.SuccEstabCSNoQueui
ng.Strm]+
[RAB.SuccEstabCSQueuing.S
trm]))*{100.00}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 958


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.SuccEstPS. none Measuremen ([RAB.SuccEstabPSNoQueui


RNC t of PS RAB ng.Bgrd]+
assignment [RAB.SuccEstabPSQueuing.B
setup per grd])+
RNC ([RAB.SuccEstabPSNoQueui
ng.Conv]+
[RAB.SuccEstabPSQueuing.C
onv])+
([RAB.SuccEstabPSNoQueui
ng.Intact]+
[RAB.SuccEstabPSQueuing.I
ntact])+
([RAB.SuccEstabPSQueuing.
Strm]+
[RAB.SuccEstabPSNoQueuin
g.Strm])

VS.PS.Call.Drop.R none Measuremen [VS.RAB.Loss.PS.RF.RNC]+


NC t of RAB [VS.RAB.Loss.PS.Abnorm.R
release NC]
triggered by
UTRAN per
RNC

VS.PS.Call.Drop.R % Measuremen (([VS.RAB.Loss.PS.RF.RNC]


NC.Rate t of RAB +
release [VS.RAB.Loss.PS.Abnorm.R
triggered by NC]))/
UTRAN per (([RAB.SuccEstabPSNoQueui
RNC ng.Bgrd]+
[RAB.SuccEstabPSQueuing.B
grd])+
([RAB.SuccEstabPSNoQueui
ng.Conv]+
[RAB.SuccEstabPSQueuing.C
onv])+
([RAB.SuccEstabPSNoQueui
ng.Intact]+
[RAB.SuccEstabPSQueuing.I
ntact])+
([RAB.SuccEstabPSQueuing.
Strm]+
[RAB.SuccEstabPSNoQueuin
g.Strm]))*{100.00}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 959


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.7.2 HSDPA KPI Weekly Report

Report Type
Simple Report

NE Type
RNC

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

HSDPA VS.HSDPA.MeanC none HSDPA [VS.HSDPA.MeanChThrough


Traffic hThroughput.Total- Measuremen put.TotalBytes]/({1024}*
MBytes t per cell {1024})

VS.HSDPA.UE.Mea numb HSDPA -


n.Cell er Measuremen
t per cell

VS.HSDPA.MeanC none HSDPA ([VS.HSDPA.MeanChThroug


hThroughput.To- Measuremen hput.TotalBytes]*{8.0}/
talMBps t per cell ({1024.0}*{1024.0}))/({GP}*
{60})

HSDPA VS.HSDPA.RAB.Su % HSDPA [VS.HSDPA.RAB.SuccEs-


Access ccEstab.Rate Measuremen tab]/[VS.HSDPA.RAB.AttEs-
t per cell tab]*{100.00}

VS.HSDPA.RAB.Su times HSDPA -


ccEstab Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 960


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.HSDPA.RAB.At times HSDPA -


tEstab Measuremen
t per cell

HSDPA VS.HSDPA.ServCel % HSDPA [VS.HSDPA.SHO.CellChg.Su


HO lChg.Succ.Rate Measuremen ccOut]/
t per cell [VS.HSDPA.SHO.CellChg.At
tOut]*{100.00}

VS.HSDPA.SHO.Ce times HSDPA -


llChg.SuccOut Measuremen
t per cell

VS.HSDPA.SHO.Ce times HSDPA -


llChg.AttOut Measuremen
t per cell

VS.HSDPA.HHO.In % HSDPA [VS.HSDPA.HHO.SuccOu-


traFreq.NoChR.Succ Measuremen tIntraFreq]/
.Rate t per cell [VS.HSDPA.HHO.AttOutIn-
traFreq]*{100.00}

VS.HSDPA.HHO.S times HSDPA -


uccOutIntraFreq Measuremen
t per cell

VS.HSDPA.HHO.At times HSDPA -


tOutIntraFreq Measuremen
t per cell

VS.HSDPA.HHO.In % HSDPA [VS.HSDPA.HHO.SuccOu-


terFreq.NoChR.Succ Measuremen tInterFreq]/
.Rate t per cell [VS.HSDPA.HHO.AttOutIn-
terFreq]*{100.00}

VS.HSDPA.HHO.S times HSDPA -


uccOutInterFreq Measuremen
t per cell

VS.HSDPA.HHO.At times HSDPA -


tOutInterFreq Measuremen
t per cell

VS.HSDPA.ChR.HS % HSDPA [VS.HSDPA.ChR.HSDSCHto


DSCHtoDCH.Succ. Measuremen DCH]/
Rate t per cell [VS.HSDPA.ChR.HSDSCHto
DCH.Att]*{100.00}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 961


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.HSDPA.ChR.HS times HSDPA -


DSCHtoDCH Measuremen
t per cell

VS.HSDPA.ChR.HS times HSDPA -


DSCHtoDCH.Att Measuremen
t per cell

VS.HSDPA.ChR.D % HSDPA [VS.HSDPA.ChR.DCHtoHSD


CHtoHSDSCH.Succ Measuremen SCH]/
.Rate t per cell [VS.HSDPA.ChR.DCHtoHSD
SCH.Att]*{100.00}

VS.HSDPA.ChR.D times HSDPA -


CHtoHSDSCH Measuremen
t per cell

VS.HSDPA.ChR.D times HSDPA -


CHtoHSDSCH.Att Measuremen
t per cell

HSDPA VS.HSDPA.RAB.A % HSDPA ([VS.HSDPA.RAB.Loss.Abn


CDR bnormRel.Rate Measuremen orm.NonRF]+
t per cell [VS.HSDPA.RAB.Loss.RF])/
([VS.HSDPA.RAB.Loss.In-
Activity]+
[VS.HSDPA.RAB.Loss.Abno
rm.NonRF]+
[VS.HSDPA.RAB.Loss.RF]+
[VS.HSDPA.RAB.Loss.Norm
]+
[VS.HSDPA.ChR.HSDSCHto
DCH]+
[VS.HSDPA.ChR.HSDSCHto
FACH]+
[VS.HSDPA.HHO.H2D.Suc-
cOutIntraFreq]+
[VS.HSDPA.HHO.H2D.Suc-
cOutInterFreq])*{100.00}

VS.HSDPA.RAB.A none HSDPA [VS.HSDPA.RAB.Loss.Abno


bnormRel Measuremen rm.NonRF]+
t per cell [VS.HSDPA.RAB.Loss.RF]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 962


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.HSDPA.RAB.Re none HSDPA [VS.HSDPA.RAB.Loss.InAc-


l Measuremen tivity]+
t per cell [VS.HSDPA.RAB.Loss.Abno
rm.NonRF]+
[VS.HSDPA.RAB.Loss.RF]+
[VS.HSDPA.RAB.Loss.Norm
]+
[VS.HSDPA.ChR.HSDSCHto
DCH]+
[VS.HSDPA.ChR.HSDSCHto
FACH]+
[VS.HSDPA.HHO.H2D.Suc-
cOutIntraFreq]+
[VS.HSDPA.HHO.H2D.Suc-
cOutInterFreq]

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.7.3 HSUPA KPI Weekly Report

Report Type
Simple Report

NE Type
RNC

Object Type
RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 963


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

HSUPA VS.HSUPA.RAB.Su % HSUPA [VS.HSUPA.RAB.SuccEs-


Access ccEstab.Rate Measuremen tab]/[VS.HSUPA.RAB.AttEs-
t per cell tab]*{100.00}

VS.HSUPA.RAB.Su numb HSUPA -


ccEstab er Measuremen
t per cell

VS.HSUPA.RAB.At numb HSUPA -


tEstab er Measuremen
t per cell

HSUPA VS.HSUPA.EDCH. % HSUPA [VS.HSUPA.EDCH.SHO.Suc


HO SHO.Succ.Ratio Measuremen c]/
t per cell [VS.HSUPA.EDCH.SHO.Att]
*{100.00}

VS.HSUPA.EDCH. times HSUPA -


SHO.Succ Measuremen
t per cell

VS.HSUPA.EDCH. times HSUPA -


SHO.Att Measuremen
t per cell

VS.HSUPA.SHO.Se % HSUPA [VS.HSUPA.SHO.ServCellCh


rvCellChg.Succ.Ra- Measuremen g.Succ]/
tio t per cell [VS.HSUPA.SHO.ServCellCh
g.Att]*{100.00}

VS.HSUPA.SHO.Se times HSUPA -


rvCellChg.Succ Measuremen
t per cell

VS.HSUPA.SHO.Se times HSUPA -


rvCellChg.Att Measuremen
t per cell

VS.HSUPA.HHO.In % HSUPA [VS.HSUPA.HHO.InterFreq.


terFreq.NoChR.Succ Measuremen NoChR.Succ]/
.Ratio t per cell [VS.HSUPA.HHO.InterFreq.
NoChR.Att]*{100.00}

VS.HSUPA.HHO.In times HSUPA -


terFreq.NoChR.Succ Measuremen
t per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 964


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.HSUPA.HHO.In times HSUPA -


terFreq.NoChR.Att Measuremen
t per cell

HSUPA VS.HSUPA.RAB.A % HSUPA ([VS.HSUPA.RAB.Loss.Ab-


CDR bnormRel.Rate Measuremen norm])/
t per cell ([VS.HSUPA.RAB.Loss.Ab-
norm]+
[VS.HSUPA.RAB.Loss.Norm
]+
[VS.HSUPA.ChR.IntraCell.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.IntraFreq.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.InterFreq.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.EDCHtoFA
CH.Succ])*{100.00}

VS.HSUPA.RAB.A none HSUPA [VS.HSUPA.RAB.Loss.Ab-


bnormRel Measuremen norm]
t per cell

VS.HSUPA.RAB.Re none HSUPA [VS.HSUPA.RAB.Loss.Ab-


lease Measuremen norm]+
t per cell [VS.HSUPA.RAB.Loss.Norm
]+
[VS.HSUPA.ChR.IntraCell.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.IntraFreq.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.InterFreq.E
DCHtoDCH.Succ]+
[VS.HSUPA.ChR.EDCHtoFA
CH.Succ]

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 965


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

21.7.4 Inter-RAT HO Report

Report Type
Simple Report

NE Type
RNC

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Inter- VS.IRATHO.AttCS times Measuremen -


RAT HO Out.RNC t related to
Report CS IRA
handover per
RNC

VS.IRATHO.SuccC times Measuremen -


SOut.RNC t related to
CS IRA
handover per
RNC

VS.IRATHO.SuccC % Measuremen [VS.IRATHO.SuccCSOut.RN


SOut.RNC.Rate t related to C]/
CS IRA [VS.IRATHO.AttCSOut.RNC
handover per ]*{100.00}
RNC

VS.SRELOC.AttPre times Measuremen -


p.IRHOCS t related to
CS IRA
handover per
RNC

VS.SRELOC.SuccPr times Measuremen -


ep.IRHOCS t related to
CS IRA
handover per
RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 966


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.SRELOC.SuccPr % Measuremen [VS.SRELOC.SuccPrep.IR-


ep.IRHOCS.Rate t related to HOCS]/
CS IRA [VS.SRELOC.AttPrep.IR-
handover per HOCS]*{100.00}
RNC

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.7.5 PAGE Report

Report Type
Simple Report

NE Type
RNC

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

PAGE VS.RANAP.Paging. times Measuremen -


Report Att.IdleUE t related to
Paging per
RNC

VS.RANAP.Paging. times Measuremen -


Succ.IdleUE t related to
Paging per
RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 967


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RANAP.Paging. % Measuremen [VS.RANAP.Paging.Succ.Idle


Succ.IdleUE.Rate t related to UE]/
Paging per [VS.RANAP.Paging.Att.IdleU
RNC E]*{100.00}

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.7.6 RAB Report

Report Type
Simple Report

NE Type
RNC

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

RAB VS.RAB.AttEstCSC numb Measuremen -


Report onv0.32.RNC er t of CS RAB
assignment
setup per
RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 968


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.SucEstCS numb Measuremen -


Conv0.32.RNC er t of CS RAB
assignment
setup per
RNC

RAB.SuccEstabCSC % Measuremen [VS.RAB.SucEstCSConv0.32.


onv0.32.RNC.Rate t of CS RAB RNC]/
assignment [VS.RAB.AttEstCSConv0.32.
setup per RNC]*{100.00}
RNC

VS.RAB.AttEstCSC numb Measuremen -


onv32.64.RNC er t of CS RAB
assignment
setup per
RNC

VS.RAB.SucEstCS numb Measuremen -


Conv32.64.RNC er t of CS RAB
assignment
setup per
RNC

RAB.SuccEstabCSC % Measuremen [VS.RAB.SucEstCSConv32.6


onv32.64.RNC.Rate t of CS RAB 4.RNC]/
assignment [VS.RAB.AttEstCSConv32.64
setup per .RNC]*{100.00}
RNC

RAB.AttEstabPS.In- numb Measuremen -


tact er t of PS RAB
assignment
setup per
RNC

VS.RAB.SucEstPSI none Measuremen [VS.RAB.SucEstPSInt0.32.R


nt.RNC t of PS RAB NC]+
assignment [VS.RAB.SucEstPSInt32.64.R
setup per NC]+
RNC [VS.RAB.SucEstPSInt64.144.
RNC]+
[VS.RAB.SucEstPSInt144384
.RNC]+
[VS.RAB.SucEstPSIntMor38
4.RNC]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 969


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.SucEstPSI % Measuremen ([VS.RAB.SucEstPSInt0.32.R


nt.RNC.Rate t of PS RAB NC]+
assignment [VS.RAB.SucEstPSInt32.64.R
setup per NC]+
RNC [VS.RAB.SucEstPSInt64.144.
RNC]+
[VS.RAB.SucEstPSInt144384
.RNC]+
[VS.RAB.SucEstPSIntMor38
4.RNC])/
[RAB.AttEstabPS.Intact]*
{100.00}

RAB.AttEstabPS.Bg numb Measuremen -


rd er t of PS RAB
assignment
setup per
RNC

VS.RAB.SucEstPSB none Measuremen [VS.RAB.SucEstPSBkg0.32.


kg.RNC t of PS RAB RNC]+
assignment [VS.RAB.SucEstPSBkg32.64.
setup per RNC]+
RNC [VS.RAB.SucEstPSBkg64.14
4.RNC]+
[VS.RAB.SucEstPSBkg14438
4.RNC]+
[VS.RAB.SucEstPSBkgMor3
84.RNC]

VS.RAB.SucEstPSB % Measuremen ([VS.RAB.SucEstPSBkg0.32.


kg.RNC.Rate t of PS RAB RNC]+
assignment [VS.RAB.SucEstPSBkg32.64.
setup per RNC]+
RNC [VS.RAB.SucEstPSBkg64.14
4.RNC]+
[VS.RAB.SucEstPSBkg14438
4.RNC]+
[VS.RAB.SucEstPSBkgMor3
84.RNC])/
[RAB.AttEstabPS.Bgrd]*
{100.00}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 970


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.7.7 RNC All Service Weekly Report

Report Type
Simple Report

NE Type
RNC

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Traffic VS.AMR.RB.DL. numb Measuremen -


12.2 er t related to
AMR service

VS.RB.DLConvCS. numb Measuremen -


64.RNC er t of RB
Procedure
per RNC

VS.CSLoad.Erlang. none Traffic -


Equiv.RNC Measuremen
t per RNC

VS.R99PSLoad.UL kbit/s Traffic -


Thruput.RNC Measuremen
t per RNC

VS.R99PSLoad.DL kbit/s Traffic -


Thruput.RNC Measuremen
t per RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 971


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.HSUPAPSLoad. kbit/s Traffic -


ULThruput.RNC Measuremen
t per RNC

VS.HSDPAPSLoad. kbit/s Traffic -


DLThruput.RNC Measuremen
t per RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 972


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Access VS.RRC.SuccConn % RRC ([RRC.SuccConnEstab.Og-


Estab.Service.Cell.R connection ConvCall]+
ate setup [RRC.SuccConnEstab.OrgStr-
measurement Call]+
per cell [RRC.SuccConnEstab.OrgItr-
Call]+
[RRC.SuccConnEstab.OrgBk
gCall]+
[RRC.SuccConnEstab.Org-
SubCall]+
[RRC.SuccConnEstab.TmCon
vCall]+
[RRC.SuccConnEstab.TmStr
Call]+
[RRC.SuccConnEstab.TmItr-
Call]+
[RRC.SuccConnEstab.TmBkg
Call]+
[RRC.SuccConnEstab.Emg-
Call]+
[RRC.SuccConnEstab.Un-
kown]+
[RRC.SuccConnEstab.OgHhP
rSig]+
[RRC.SuccConnEstab.OgLwP
rSig]+
[RRC.SuccConnEstab.CallRe-
Est]+
[RRC.SuccConnEstab.TmHhP
rSig]+
[RRC.SuccConnEstab.TmLw
PrSig])/
([RRC.AttConnEstab.Org-
ConvCall]+
[RRC.AttConnEstab.OrgStr-
Call]+
[RRC.AttConnEstab.OrgInter-
Call]+
[RRC.AttConnEstab.OrgBkg-
Call]+
[RRC.AttConnEstab.OgSub-
Call]+
[RRC.AttConnEstab.TmConv
Call]+
[RRC.AttConnEstab.TmStrCa
ll]+
[RRC.AttConnEstab.TmInter-

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 973


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Call]+
[RRC.AttConnEstab.TmBkgC
all]+
[RRC.AttConnEstab.Emg-
Call]+
[RRC.AttConnEstab.Un-
known]+
[RRC.AttConnEstab.OgHhPr-
Sig]+
[RRC.AttConnEstab.OgLwPr-
Sig]+
[RRC.AttConnEstab.CallRe-
Est]+
[RRC.AttConnEstab.TmHhPr
Sig]+
[RRC.AttConnEstab.TmLwPr
Sig])*{100.00}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 974


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RRC.SuccConn none RRC [RRC.SuccConnEstab.Og-


Estab.Service.Cell connection ConvCall]+
setup [RRC.SuccConnEstab.OrgStr-
measurement Call]+
per cell [RRC.SuccConnEstab.OrgItr-
Call]+
[RRC.SuccConnEstab.OrgBk
gCall]+
[RRC.SuccConnEstab.Org-
SubCall]+
[RRC.SuccConnEstab.TmCon
vCall]+
[RRC.SuccConnEstab.TmStr
Call]+
[RRC.SuccConnEstab.TmItr-
Call]+
[RRC.SuccConnEstab.TmBkg
Call]+
[RRC.SuccConnEstab.Emg-
Call]+
[RRC.SuccConnEstab.Un-
kown]+
[RRC.SuccConnEstab.OgHhP
rSig]+
[RRC.SuccConnEstab.OgLwP
rSig]+
[RRC.SuccConnEstab.CallRe-
Est]+
[RRC.SuccConnEstab.TmHhP
rSig]+
[RRC.SuccConnEstab.TmLw
PrSig]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 975


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RRC.AttConnEs none RRC [RRC.AttConnEstab.Org-


tab.Service.Cell connection ConvCall]+
setup [RRC.AttConnEstab.OrgStr-
measurement Call]+
per cell [RRC.AttConnEstab.OrgInter-
Call]+
[RRC.AttConnEstab.OrgBkg-
Call]+
[RRC.AttConnEstab.OgSub-
Call]+
[RRC.AttConnEstab.TmConv
Call]+
[RRC.AttConnEstab.TmStrCa
ll]+
[RRC.AttConnEstab.TmInter-
Call]+
[RRC.AttConnEstab.TmBkgC
all]+
[RRC.AttConnEstab.Emg-
Call]+
[RRC.AttConnEstab.Un-
known]+
[RRC.AttConnEstab.OgHhPr-
Sig]+
[RRC.AttConnEstab.OgLwPr-
Sig]+
[RRC.AttConnEstab.CallRe-
Est]+
[RRC.AttConnEstab.TmHhPr
Sig]+
[RRC.AttConnEstab.TmLwPr
Sig]

VS.RRC.SuccConn % RRC ([RRC.SuccConnEstab.IRAT-


Estab.Other.Cell.Rat connection CelRes]+
e setup [RRC.SuccConnEstab.IRATC
measurement CO]+
per cell [RRC.SuccConnEstab.Reg]+
[RRC.SuccConnEstab.De-
tach])/
([RRC.AttConnEstab.IRAT-
CelRes]+
[RRC.AttConnEstab.IRATC-
CO]+
[RRC.AttConnEstab.Reg]+
[RRC.AttConnEstab.Detach])
*{100.00}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 976


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RRC.SuccConn none RRC [RRC.SuccConnEstab.IRAT-


Estab.Other.Cell connection CelRes]+
setup [RRC.SuccConnEstab.IRATC
measurement CO]+
per cell [RRC.SuccConnEstab.Reg]+
[RRC.SuccConnEstab.Detach]

VS.RRC.AttConnEs none RRC [RRC.AttConnEstab.IRAT-


tab.Other.Cell connection CelRes]+
setup [RRC.AttConnEstab.IRATC-
measurement CO]+
per cell [RRC.AttConnEstab.Reg]+
[RRC.AttConnEstab.Detach]

VS.RAB.SuccEstab % Measuremen [VS.RAB.SuccEstab.AMR]/


CS.AMR.Cell.Rate t of CS RAB [VS.RAB.AttEstab.AMR]*
assignment {100.00}
setup per cell

VS.RAB.SuccEstab. numb Measuremen -


AMR er t of CS RAB
assignment
setup per cell

VS.RAB.AttEstab.A numb Measuremen -


MR er t of CS RAB
assignment
setup per cell

VS.RAB.SuccEstab % Measuremen [VS.RAB.SuccEstCS.Conv.


CS.Conv. t of CS RAB 64]/[VS.RAB.AttEstCS.Conv.
64.Cell.Rate assignment 64]*{100.00}
setup per cell

VS.RAB.SuccEstCS numb Measuremen -


.Conv.64 er t of CS RAB
assignment
setup per cell

VS.RAB.AttEstCS. numb Measuremen -


Conv.64 er t of CS RAB
assignment
setup per cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 977


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.SuccEstab % Measuremen ([VS.RAB.SuccEstabPS.Conv


PS.Cell.Rate t of PS RAB ]+[VS.RAB.SuccEstabPS.Str]
assignment +[VS.RAB.SuccEstabPS.In-
setup per cell ter]+
[VS.RAB.SuccEstabPS.Bkg])/
([VS.RAB.AttEstabPS.Conv]
+[VS.RAB.AttEstabPS.Str]+
[VS.RAB.AttEstabPS.Inter]+
[VS.RAB.AttEstabPS.Bkg])*
{100.00}

VS.RAB.SuccEstPS. none Measuremen [VS.RAB.SuccEstabPS.Conv]


Cell t of PS RAB +[VS.RAB.SuccEstabPS.Str]+
assignment [VS.RAB.SuccEstabPS.Inter]
setup per cell +[VS.RAB.SuccEstabPS.Bkg]

VS.RAB.AttEstabPS numb Measuremen [VS.RAB.AttEstabPS.Conv]+


.Cell er t of PS RAB [VS.RAB.AttEstabPS.Str]+
assignment [VS.RAB.AttEstabPS.Inter]+
setup per cell [VS.RAB.AttEstabPS.Bkg]

HO VS.SHO.Factor.RL none Soft ([VS.SHO.AS.1]+


Handover [VS.SHO.AS.2Softer]*{2}+
Measuremen [VS.SHO.AS.2Soft]*{2}+
t per RNC [VS.SHO.AS.3Softer]*{3}+
[VS.SHO.AS.3Soft]*{3}+
[VS.SHO.AS.3Soft2Softer]*
{3}+[VS.SHO.AS.4]*{4}+
[VS.SHO.AS.5]*{5}+
[VS.SHO.AS.6]*{6})/
([VS.SHO.AS.1]+
[VS.SHO.AS.2Softer]+
[VS.SHO.AS.2Soft]+
[VS.SHO.AS.3Softer]+
[VS.SHO.AS.3Soft]+
[VS.SHO.AS.3Soft2Softer]+
[VS.SHO.AS.4]+
[VS.SHO.AS.5]+
[VS.SHO.AS.6])-{1}

VS.SHO.Succ.Rate % Soft [VS.SHO.Succ]/


Handover [VS.SHO.Att.RNC]*{100.00}
Measuremen
t per RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 978


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.SHO.Succ times Soft -


Handover
Measuremen
t per RNC

VS.SHO.Att.RNC times Soft -


Handover
Measuremen
t per RNC

VS.InterFreq.HHO.S % Hard [VS.HHO.InterFreq.Succ.RN


ucc.RNC.Rate Handover C]/
Measuremen [VS.HHO.InterFreq.Att.RNC]
t per RNC *{100.00}

VS.HHO.InterFreq.S times Hard -


ucc.RNC Handover
Measuremen
t per RNC

VS.HHO.InterFreq. times Hard -


Att.RNC Handover
Measuremen
t per RNC

VS.IRATHO.SuccC % Measuremen [VS.IRATHO.SuccCSOut.RN


SOut.RNC.Rate t related to C]/
CS IRA [VS.IRATHO.AttCSOut.RNC
handover per ]*{100.00}
RNC

VS.IRATHO.SuccC times Measuremen -


SOut.RNC t related to
CS IRA
handover per
RNC

VS.IRATHO.AttCS times Measuremen -


Out.RNC t related to
CS IRA
handover per
RNC

VS.IRATHO.SuccP % Measuremen [VS.IRATHO.SuccPSOutUT


SOutUTRAN.RNC. t related to PS RAN.RNC]/
Rate IRA [VS.IRATHO.AttPSOutUTR
handover per AN.RNC]*{100.00}
RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 979


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.IRATHO.SuccP times Measuremen -


SOutUTRAN.RNC t related to PS
IRA
handover per
RNC

VS.IRATHO.AttPS times Measuremen -


OutUTRAN.RNC t related to PS
IRA
handover per
RNC

CDR VS.Abnorm.Rel.CS. times Measuremen -


AMR.IurLink t related to
SRNC in Iur
interface

VS.Rel.CS.AMR.Iur none Measuremen [VS.Norm.Rel.CS.AMR.Iur-


Link t related to Link]+
SRNC in Iur [VS.Abnorm.Rel.CS.AMR.Iur
interface Link]

VS.RAB.Loss.CS.A numb Measuremen -


MR er t of RAB
release
triggered by
UTRAN per
cell

VS.CS.AMR.Re- none Measuremen [VS.RAB.Loss.CS.AMR]+


lease t of RAB [VS.RAB.Loss.CS.Norm.AM
release R]
triggered by
UTRAN per
cell

VS.Abnorm.Rel.CS. times Measuremen -


Conv.RB.64.IurLink t related to
SRNC in Iur
interface

VS.Rel.CS.VP.Iur- none Measuremen [VS.Norm.Rel.CS.Conv.RB.


Link t related to 64.IurLink]+
SRNC in Iur [VS.Abnorm.Rel.CS.Conv.RB
interface .64.IurLink]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 980


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RAB.Loss.CS.C numb Measuremen -


onv64K er t of RAB
release
triggered by
UTRAN per
cell

VS.CS.VP.Release none Measuremen [VS.RAB.Loss.CS.Conv64K]


t of RAB +[VS.Norm.Rel.CS.Conv.RB.
release 64]
triggered by
UTRAN per
cell

VS.Abnorm.Rel.PS.I none Measuremen [VS.Abnorm.Rel.PS.BE.RB.


urLink t related to 0.32.IurLink]+
SRNC in Iur [VS.Abnorm.Rel.PS.BE.RB.
interface 32.64.IurLink]+
[VS.Abnorm.Rel.PS.BE.RB.
64.144.IurLink]+
[VS.Abnorm.Rel.PS.BE.RB.
144.384.IurLink]+
[VS.Abnorm.Rel.PS.CCH.Iur-
Link]

VS.Rel.PS.IurLink none Measuremen [VS.Norm.Rel.PS.BE.RB.


t related to 0.32.IurLink]+
SRNC in Iur [VS.Norm.Rel.PS.BE.RB.
interface 32.64.IurLink]+
[VS.Norm.Rel.PS.BE.RB.
64.144.IurLink]+
[VS.Norm.Rel.PS.BE.RB.
144.384.IurLink]+
[VS.Norm.Rel.PS.CCH.Iur-
Link]+
[VS.Abnorm.Rel.PS.BE.RB.
0.32.IurLink]+
[VS.Abnorm.Rel.PS.BE.RB.
32.64.IurLink]+
[VS.Abnorm.Rel.PS.BE.RB.
64.144.IurLink]+
[VS.Abnorm.Rel.PS.BE.RB.
144.384.IurLink]+
[VS.Abnorm.Rel.PS.CCH.Iur-
Link]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 981


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.PS.Call.Drop.Ce numb Measuremen [VS.RAB.Loss.PS.RF]+


ll er t of RAB [VS.RAB.Loss.PS.Abnorm]
release
triggered by
UTRAN per
cell

VS.PS.RAB.Release none Measuremen [VS.RAB.Loss.PS.RF]+


t of RAB [VS.RAB.Loss.PS.Abnorm]+
release [VS.RAB.Loss.PS.Norm]
triggered by
UTRAN per
cell

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.7.8 RRC Report

Report Type
Simple Report

NE Type
RNC

Object Type
RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 982


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

RRC VS.RRC.AttCon- times RRC -


Report nEstab connection
setup
measurement
per RNC

VS.RRC.FailConEst times RRC -


.RNC connection
setup
measurement
per RNC

VS.RRC.SetupCon- times RRC -


nEstab connection
setup
measurement
per RNC

VS.RRC.SuccCon- times RRC -


nEstab connection
setup
measurement
per RNC

VS.RRC.SuccConn % RRC [VS.RRC.SuccConnEstab]/


Estab.Rate connection [VS.RRC.AttConnEstab]*
setup {100.00}
measurement
per RNC

VS.RRC.AttConnEs none RRC [VS.RRC.AttConnEstab.Org-


tab.Conv connection Conv]+
setup [VS.RRC.AttConnEstab.Trm
measurement Conv]
per RNC

VS.RRC.SuccConn none RRC [VS.RRC.SuccConnEstab.Org


Estab.Conv connection Conv]+
setup [VS.RRC.SuccConnEstab.Tr
measurement mConv]
per RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 983


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RRC.SuccConn % RRC ([VS.RRC.SuccConnEstab.Or


Estab.Conv.Rate connection gConv]+
setup [VS.RRC.SuccConnEstab.Tr
measurement mConv])/
per RNC ([VS.RRC.AttConnEstab.Org-
Conv]+
[VS.RRC.AttConnEstab.Trm
Conv])*{100.00}

VS.RRC.AttConnEs none RRC [VS.RRC.AttConnEstab.OrgB


tab.Bkg connection kg]+
setup [VS.RRC.AttConnEstab.Trm
measurement Bkg]
per RNC

VS.RRC.SuccConn none RRC [VS.RRC.SuccConnEstab.Org


Estab.Bkg connection Bkg]+
setup [VS.RRC.SuccConnEstab.Tr
measurement mBkg]
per RNC

VS.RRC.SuccConn % RRC ([VS.RRC.SuccConnEstab.Or


Estab.Bkg.Rate connection gBkg]+
setup [VS.RRC.SuccConnEstab.Tr
measurement mBkg])/
per RNC ([VS.RRC.AttConnEstab.Org
Bkg]+
[VS.RRC.AttConnEstab.Trm
Bkg])*{100.00}

VS.RRC.AttConnEs none RRC [VS.RRC.AttConnEstab.Or-


tab.Int connection gInt]+
setup [VS.RRC.AttConnEstab.TrmI
measurement nt]
per RNC

VS.RRC.SuccConn none RRC [VS.RRC.SuccConnEstab.Or-


Estab.Int connection gInt]+
setup [VS.RRC.SuccConnEstab.Tr
measurement mInt]
per RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 984


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RRC.SuccConn % RRC ([VS.RRC.SuccConnEstab.Or


Estab.Int.Rate connection gInt]+
setup [VS.RRC.SuccConnEstab.Tr
measurement mInt])/
per RNC ([VS.RRC.AttConnEstab.Or-
gInt]+
[VS.RRC.AttConnEstab.TrmI
nt])*{100.00}

VS.RRC.AttConnEs none RRC [VS.RRC.AttConnEstab.Trm


tab.Trm connection Conv]+
setup [VS.RRC.AttConnEstab.TrmS
measurement tr]+
per RNC [VS.RRC.AttConnEstab.TrmI
nt]+
[VS.RRC.AttConnEstab.Trm
Bkg]

VS.RRC.SuccConn none RRC [VS.RRC.SuccConnEstab.Tr


Estab.Trm connection mConv]+
setup [VS.RRC.SuccConnEstab.Tr
measurement mStr]+
per RNC [VS.RRC.SuccConnEstab.Tr
mInt]+
[VS.RRC.SuccConnEstab.Tr
mBkg]

VS.RRC.SuccConn % RRC ([VS.RRC.SuccConnEstab.Tr


Estab.Trm.Rate connection mConv]+
setup [VS.RRC.SuccConnEstab.Tr
measurement mStr]+
per RNC [VS.RRC.SuccConnEstab.Tr
mInt]+
[VS.RRC.SuccConnEstab.Tr
mBkg])/
([VS.RRC.AttConnEstab.Trm
Conv]+
[VS.RRC.AttConnEstab.TrmS
tr]+
[VS.RRC.AttConnEstab.TrmI
nt]+
[VS.RRC.AttConnEstab.Trm
Bkg])*{100.00}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 985


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VS.RRC.AttConnEs times RRC -


tab.CellRes connection
setup
measurement
per RNC

VS.RRC.SuccConn times RRC -


Estab.CellRes connection
setup
measurement
per RNC

VS.RRC.SuccConn % RRC [VS.RRC.SuccConnEstab.Cell


Estab.CellRes.Rate connection Res]/
setup [VS.RRC.AttConnEstab.CellR
measurement es]*{100.00}
per RNC

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.7.9 Traffic Weekly BH Report

Report Type
Simple Report

NE Type
RNC

Object Type
RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 986


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Traffic VS.CSLoad.Erlang. none Traffic -


Weekly Equiv.RNC Measuremen
BH t per RNC

VS.R99PSLoad.DL kbit/s Traffic -


Thruput.RNC Measuremen
t per RNC

VS.HSDPAPSLoad. kbit/s Traffic -


DLThruput.RNC Measuremen
t per RNC

VS.MBMSPSLoad. kbit/s Traffic -


DLThruput.RNC Measuremen
t per RNC

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

21.7.10 Traffic Weekly Report

Report Type
Simple Report

NE Type
RNC

Object Type
RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 987


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 21 UMTS RAN Professional Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Traffic VS.CSLoad.Erlang. none Traffic -


Weekly Equiv.RNC Measuremen
t per RNC

VS.R99PSLoad.DL kbit/s Traffic -


Thruput.RNC Measuremen
t per RNC

VS.HSDPAPSLoad. kbit/s Traffic -


DLThruput.RNC Measuremen
t per RNC

VS.MBMSPSLoad. kbit/s Traffic -


DLThruput.RNC Measuremen
t per RNC

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 988


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 22 USN Performance Report

22 USN Performance Report

About This Chapter

22.1 Gb mode Report

22.2 Iu mode Report

22.3 Link Report

22.4 Data transfer Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 989


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 22 USN Performance Report

22.1 Gb mode Report


Report Type
Simple Report

NE Type
USN

Object Type
USN and SGSN

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Gb mode Gb mode GPRS times Gb mode -


mobility attach request times attach
manage
ment Gb mode intra-SGSN times Gb mode -
RAU request times intra-SGSN
RAU

Gb mode Inter- times Gb mode -


SGSN RAU request inter-SGSN
times RAU

Gb mode Gb mode MS init times Gb mode -


session PDP context act PDP context
manage activation
ment

Gb mode Gb mode average numb Gb mode -


resource attached users er radio
resource

Gb mode average act numb Gb mode SM -


PDP context er resource

Gb mode Gb mode packet times Gb mode -


paging paging request times paging

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 990


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 22 USN Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

22.2 Iu mode Report


Report Type
Simple Report

NE Type
USN

Object Type
USN and SGSN

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Iu mode Iu mode GPRS attach times Iu mode -


mobility request times attach
manage
ment Iu mode intra-SGSN times Iu mode -
RAU request times intra-SGSN
RAU

Iu mode Inter-SGSN times Iu mode -


RAU request times inter-SGSN
RAU

Iu mode Iu mode MS init PDP times Iu mode PDP -


session context act context
manage activation
ment

Iu mode Iu mode average numb Iu mode radio -


resource attached users er resource

Iu mode average numb Iu mode SM -


active PDP context er resource

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 991


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 22 USN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Iu mode Iu mode packet times Iu mode -


paging paging request times paging

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

22.3 Link Report


Report Type
Simple Report

NE Type
USN

Object Type
MTP3 link

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

MTP3 MTP3 link send load Erl MTP3 link -


link
MTP3 link receive Erl MTP3 link -
load

MTP3 link times MTP3 link -


congestion

MTP3 link durations s MTP3 link -


of congestion

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 992


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 22 USN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

MTP3 link durations s MTP3 link -


of unavailable

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

22.4 Data transfer Report


Report Type
Simple Report

NE Type
USN

Object Type
USN and SGSN

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Data GTP Kbytes sent to kB GTPU bearer -


transfer GGSN

GTP Kbytes received kB GTPU bearer -


from GGSN

Downlink data kB GTPU bearer -


Kbytes sent to
SNDCP

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 993


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 22 USN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Uplink data Kbytes kB GTPU bearer -


received from
SNDCP

Downlink data kB GTPU bearer -


Kbytes sent to RNC

Uplink data Kbytes kB GTPU bearer -


received from RNC

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 994


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 23 UGW Performance Report

23 UGW Performance Report

About This Chapter

23.1 AAA performance Report

23.2 Session Service Report

23.3 Data transfer Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 995


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 23 UGW Performance Report

23.1 AAA performance Report


Report Type
Simple Report

NE Type
UGW

Object Type
UGW and GGSN

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

AAA Authentication times AAA -


performa requests performance
nce measurement

Accounting start times AAA -


requests performance
measurement

Accounting stop times AAA -


requests performance
measurement

Real-time accounting times AAA -


requests performance
measurement

APN Authentication times AAA -


AAA requests performance
Performa measurement
nce (specified
APN)

Accounting start times AAA -


requests performance
measurement
(specified
APN)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 996


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 23 UGW Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Accounting stop times AAA -


requests performance
measurement
(specified
APN)

Real-time accounting times AAA -


requests performance
measurement
(specified
APN)

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

23.2 Session Service Report


Report Type
Simple Report

NE Type
UGW

Object Type
UGW and GGSN

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 997


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 23 UGW Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Basic PDP context times GGSN Basic -


session activation requests session
service performance
measurement

Current activated numb GGSN Basic -


PDP contexts er session
performance
measurement

Apn GTPv1 MS-init. times GTPv1 -


session activation requests session
performa measurement
nce (specified
APN)

GTPv0 MS-init. times GTPv0 -


activation requests session
measurement
(specified
APN)

Current activated numb Session -


PDP contexts (APN) er status
measurement
(specified
APN)

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

23.3 Data transfer Report


Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 998


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 23 UGW Performance Report

NE Type
UGW

Object Type
UGW and GGSN

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Data Gn peak throughput MB/s GGSN -


transfer in MB/s Forwarding
measure performance
ment measurement

Gi peak throughput MB/s GGSN -


in MB/s Forwarding
performance
measurement

Gn uplink traffic in MB GGSN -


MB Forwarding
performance
measurement

Gn downlink traffic MB GGSN -


in MB Forwarding
performance
measurement

Gi uplink traffic in MB GGSN -


MB Forwarding
performance
measurement

Gi downlink traffic in MB GGSN -


MB Forwarding
performance
measurement

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 999


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 23 UGW Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1000


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 24 SGSN Performance Report

24 SGSN Performance Report

About This Chapter

24.1 Gb mode Report

24.2 Iu mode Report

24.3 Common Report

24.4 Link Report

24.5 Data transfer Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1001


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 24 SGSN Performance Report

24.1 Gb mode Report


Report Type
Simple Report

NE Type
SGSN

Object Type
USN and SGSN

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Gb mode Gb mode GPRS times Gb mode -


mobility attach request times attach
manage
ment Gb mode GPRS % Gb mode {100}*[Gb mode GPRS attach
attach success ratio attach accept times]/[Gb mode GPRS
attach request times]

Gb mode intra-SGSN times Gb mode -


RAU request times intra-SGSN
RAU

Gb mode intra-SGSN % Gb mode {100}*[Gb mode intra-SGSN


RAU success ratio intra-SGSN RAU success times]/[Gb mode
RAU intra-SGSN RAU request
times]

Gb mode inter-SGSN times Gb mode -


RAU request times inter-SGSN
RAU

Gb mode inter-RAU % Gb mode {100}*[Gb mode inter-SGSN


success ratio inter-SGSN RAU success times]/[Gb mode
RAU inter-SGSN RAU request
times]

Gb mode Gb mode MS init times Gb mode -


session PDP context act PDP context
manage activation
ment

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1002


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 24 SGSN Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Gb mode MS init % Gb mode {100}*[Gb mode MS init PDP


PDP context act PDP context context act success]/[Gb mode
success ratio activation MS init PDP context act]

Gb mode Gb mode average numb Gb mode -


resource attached users er radio
resource

Gb mode average act numb Gb mode SM -


PDP context er resource

Gb mode Gb mode packet times Gb mode -


paging paging request times paging

Gb mode packet % Gb mode {100}*({1}-[Gb mode packet


paging success ratio paging paging none-response times]/
[Gb mode packet paging
request times])

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

24.2 Iu mode Report


Report Type
Simple Report

NE Type
SGSN

Object Type
USN and SGSN

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1003


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 24 SGSN Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Iu mode Iu mode GPRS attach times Iu mode -


mobility request times attach
manage
ment Iu mode GPRS attach % Iu mode {100}*[Iu mode GPRS attach
suucess ratio attach success times]/[Iu mode GPRS
attach request times]

Iu mode intra-SGSN times Iu mode -


RAU request times intra-SGSN
RAU

Iu mode intra-RAU % Iu mode {100}*[Iu mode intra-SGSN


success ratio intra-SGSN RAU success times]/[Iu mode
RAU intra-SGSN RAU request
times]

Iu mode inter-SGSN times Iu mode -


RAU request times inter-SGSN
RAU

Iu mode inter-RAU % Iu mode {100}*[Iu mode inter-SGSN


success ratio inter-SGSN RAU success times]/[Iu mode
RAU inter-SGSN RAU request
times]

Iu mode Iu mode MS init PDP times Iu mode PDP -


session context act context
manage activation
ment
Iu mode MS init PDP % Iu mode PDP {100}*[Iu mode MS init PDP
context act success context context act success]/[Iu mode
ratio activation MS init PDP context act]

Iu mode Iu mode average numb Iu mode radio -


resource attached users er resource

Iu mode average numb Iu mode SM -


active PDP context er resource

Iu mode Iu mode packet times Iu mode -


paging paging request times paging

Iu mode packet % Iu mode ({1}-[Iu mode packet paging


paging success ratio paging none-response times]/[Iu mode
packet paging request times])*
{100}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1004


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 24 SGSN Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

24.3 Common Report


Report Type
Simple Report

NE Type
SGSN

Object Type
Board

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

CPU CPU overload times times System -


resource resource

CPU overload s System -


duration resource

CPU congestion times System -


times resource

CPU congestion s System -


duration resource

Average CPU % System -


occupation ratio(%) resource

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1005


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 24 SGSN Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

24.4 Link Report


Report Type
Simple Report

NE Type
SGSN

Object Type
MTP3 link

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

MTP3 MTP3 link send load Erl MTP3 link -


link (erl)

MTP3 link receive Erl MTP3 link -


load(erl)

MTP3 link times MTP3 link -


congestion

MTP3 link durations s MTP3 link -


of congestion

MTP3 link durations s MTP3 link -


of unavailable

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1006


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 24 SGSN Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

24.5 Data transfer Report


Report Type
Simple Report

NE Type
SGSN

Object Type
USN and SGSN

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Data GTP kbytes sent to kiloby GTPU bearer -


transfer GGSN tes

GTP kbytes received kiloby GTPU bearer -


from GGSN tes

Downlink data kiloby GTPU bearer -


kbytes sent to tes
SNDCP

Uplink data kbytes kiloby GTPU bearer -


received from tes
SNDCP

Downlink data kiloby GTPU bearer -


kbytes sent to RNC tes

Uplink data kbytes kiloby GTPU bearer -


received from RNC tes

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1007


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 24 SGSN Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1008


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 25 SG7000 Performance Report

25 SG7000 Performance Report

About This Chapter

25.1 SG7000 Performance Report_1

25.2 SG7000 Performance Report_2

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1009


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 25 SG7000 Performance Report

25.1 SG7000 Performance Report_1

25.1.1 DSP Report

Report Type
Simple Report

NE Type
SG7000

Object Type
DSP

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

DSP Duration of adjacent s DSP -


SP inaccessible

MSU discarded due numb DSP -


to a routing data error er

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

25.1.2 Link Report

Report Type
Simple Report

NE Type
SG7000

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1010


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 25 SG7000 Performance Report

Object Type
Link

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

LINK Duration of SL s LINK -


unavailability(for
any reason)

Duration of link in s LINK -


the In-service state

MSUs discarded due numb LINK -


to SL congestion er

Number of SIF and numb LINK -


SIO octets received er

Number of SIF and numb LINK -


SIO octets er
transmitted

Number of message numb LINK -


signal units received er

Number of message numb LINK -


signal units er
transmitted

Number of negative times LINK -


ack. Received

Number of signal times LINK -


units received in
error

SL alignment or numb LINK -


proving failure er

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1011


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 25 SG7000 Performance Report

25.1.3 LinkSet Report

Report Type
Simple Report

NE Type
SG7000

Object Type
Link Set

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

LINKSE Duration of s LINKSET -


T unavailability of
signalling linkset

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

25.1.4 M3UA ASSOAS Report

Report Type
Simple Report

NE Type
SG7000

Object Type
M3UA ASSOAS

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1012


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 25 SG7000 Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

M3UA Duration of adjacent s M3UA -


ASSOAS AS inaccessible ASSOAS

Duration of route set s M3UA -


to a given destination ASSOAS
unavailability

Message discarded numb M3UA -


due to a routing data er ASSOAS
error

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

25.1.5 M3UA Link Report

Report Type
Simple Report

NE Type
SG7000

Object Type
M3UA Link

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

M3UA Bytes of receieved byte M3UA LINK -


Link message in one m3ua
association

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1013


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 25 SG7000 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Bytes of sent byte M3UA LINK -


message in one m3ua
association

Duration of m3ua s M3UA LINK -


association
availability

Duration of m3ua s M3UA LINK -


association
unavailability

Number of receieved times M3UA LINK -


message in one m3ua
association

Number of sent numb M3UA LINK -


message in one m3ua er
association

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

25.1.6 M3UA LinkSet Report

Report Type
Simple Report

NE Type
SG7000

Object Type
M3UA Link Set

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1014


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 25 SG7000 Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

M3UA Duration of m3ua s M3UA -


LinkSet association set LINKSET
unavailability

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

25.1.7 SCCP globle Report

Report Type
Simple Report

NE Type
SG7000

Object Type
SG7000NE

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

SCCP Total messages numb SCCP global -


globle requiring global title er
translation

UDT messages numb SCCP global -


received er

UDT messages sent numb SCCP global -


er

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1015


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 25 SG7000 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

UDTS messages numb SCCP global -


received er

UDTS messages sent numb SCCP global -


er

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

25.2 SG7000 Performance Report_2

25.2.1 CPU Usage Report

Report Type
Simple Report

NE Type
SG7000

Object Type
CPU Load

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

CPU CPU average usage % CPU Load -


Usage
Report CPU peak usage % CPU Load -

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1016


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 25 SG7000 Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

25.2.2 DSP and Link Set Load Report

Report Type
Combined Report

Simple Report(s) List


l DSP Report
l Link Set Load Report

DSP Report

NE Type
SG7000

Object Type
DSP

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

DSP Duration of s DSP -


Report unavailability

Times of times DSP -


unavailability

Discarded MSU numb DSP -


er

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1017


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 25 SG7000 Performance Report

Link Set Load Report

NE Type
SG7000

Object Type
Link Set

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Link Set Transmitted load Erl LINK -


Load
Report Received load Erl LINK -

Transmitted and Erl LINK [Transmitted load]+[Received


received load load]

Number of message numb LINK -


signal units received er

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

25.2.3 DSP Report

Report Type
Simple Report

NE Type
SG7000

Object Type
DSP

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1018


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 25 SG7000 Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

DSP Duration of s DSP -


Report unavailability

Times of times DSP -


unavailability

Discarded MSU numb DSP -


er

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

25.2.4 Link Load Busy Hour Report

Report Type
DB-based Report

NE Type
SG7000

Object Type
Link

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Link Maximum received Erl LINK -


Load load
Busy
Hour Maximum Erl LINK -
Report transmitted load

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1019


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 25 SG7000 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Maximum Erl LINK [Transmitted load]+[Received


bidirectional load load]

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

25.2.5 Link Load Report

Report Type
Simple Report

NE Type
SG7000

Object Type
Link

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Link Number of SIF and numb LINK -


Load SIO octets er
Report transmitted

Number of message numb LINK -


signal units er
transmitted

Maximum Erl LINK -


transmitted load

Average transmitted Erl LINK -


load

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1020


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 25 SG7000 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Number of SIF and numb LINK -


SIO octets received er

Number of message numb LINK -


signal units received er

Maximum received Erl LINK -


load

Average received Erl LINK -


load

Average transmitted Erl LINK -


and received load

Average number of numb LINK [Number of SIF and SIO octets


SIF and SIO octets er transmitted]/[Number of
transmitted per MSU message signal units
transmitted]

Average number of numb LINK [Number of SIF and SIO octets


SIF and SIO octets er received]/[Number of message
received per MSU signal units received]

Duration of link in s LINK -


the In-service state

Number of signal times LINK -


units received in
error

Maximum Erl LINK MAX([Maximum transmitted


transmitted/received load],[Maximum received
load load])

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1021


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 25 SG7000 Performance Report

25.2.6 Link Set Load Busy Hour Report

Report Type
DB-based Report

NE Type
SG7000

Object Type
Link Set

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Link Set Maximum received Erl LINK -


Load load
Busy
Hour Maximum Erl LINK -
Report transmitted load

Maximum Erl LINK [Transmitted load]+[Received


bidirectional load load]

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

25.2.7 Link Set Load Report

Report Type
Simple Report

NE Type
SG7000

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1022


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 25 SG7000 Performance Report

Object Type
Link Set

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Link Set Transmitted load Erl LINK -


Load
Report Received load Erl LINK -

Transmitted and Erl LINK [Transmitted load]+[Received


received load load]

Number of message numb LINK -


signal units received er

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

25.2.8 Link Usage and Availability Report

Report Type
Simple Report

NE Type
SG7000

Object Type
Link

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1023


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 25 SG7000 Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Link Transmitted load Erl LINK -


Usage
and Received load Erl LINK -
Availabil Transmitted MSU numb LINK -
ity per sencond er
Report
Received MSU per numb LINK -
sencond er

Number of message numb LINK -


signal units er
transmitted

Number of message numb LINK -


signal units received er

Bytes of transmitted numb LINK -


messages er

Bytes of received numb LINK -


messages er

Duration of s LINK -
availability

Duration of s LINK -
unavailability

Link usage % LINK -

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

25.2.9 M2PA Link Busy Hour Report

Report Type
DB-based Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1024


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 25 SG7000 Performance Report

NE Type
SG7000

Object Type
Link

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

M2PA Maximum sent numb M2PA LINK -


Link messages er
Busy
Hour Bytes of sent byte M2PA LINK -
Report messages

Maximum received numb M2PA LINK -


messages er

Bytes of received byte M2PA LINK -


messages

Maximum sent/ numb M2PA LINK -


received messages er

Maximum numb M2PA LINK [Number of sent status message


bidirectional er in one m2pa link]+[Number of
messages received status message in one
m2pa link]

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

25.2.10 M2PA Link Report

Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1025


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 25 SG7000 Performance Report

NE Type
SG7000

Object Type
Link

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

M2PA Total number of numb M2PA LINK -


Link transmitted messages er
Report
Maximum number of numb M2PA LINK -
transmitted messages er

Minimum number of numb M2PA LINK -


transmitted messages er

Average number of numb M2PA LINK -


transmitted messages er

Bytes of transmitted byte M2PA LINK -


messages

Total number of numb M2PA LINK -


received messages er

Maximum number of numb M2PA LINK -


received messages er

Minimum number of numb M2PA LINK -


received messages er

Average number of numb M2PA LINK -


received messages er

Bytes of received byte M2PA LINK -


messages

Duration of s M2PA LINK -


availability

Duration of s M2PA LINK -


unavailability

Maximum number of numb M2PA LINK MAX([Maximum number of


transmitted/received er transmitted messages],
messages [Maximum number of received
messages])

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1026


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 25 SG7000 Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

25.2.11 M3UA Link Busy Hour Report

Report Type
DB-based Report

NE Type
SG7000

Object Type
M3UA Link

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

M3UA Maximum sent numb M3UA LINK -


Link messages er
Busy
Hour Bytes of sent byte M3UA LINK -
Report messages

Maximum received numb M3UA LINK -


messages er

Bytes of received byte M3UA LINK -


messages

Maximum sent/ numb M3UA LINK -


received messages er

Maximum numb M3UA LINK [Number of sent message in


bidirectional er one m3ua association]+
messages [Number of receieved message
in one m3ua association]

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1027


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 25 SG7000 Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

25.2.12 M3UA Link Report

Report Type
Simple Report

NE Type
SG7000

Object Type
M3UA Link

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

M3UA Total number of numb M3UA LINK -


Link transmitted messages er
Report
Maximum number of numb M3UA LINK -
transmitted messages er

Minimum number of numb M3UA LINK -


transmitted messages er

Average number of numb M3UA LINK -


transmitted messages er

Bytes of transmitted byte M3UA LINK -


messages

Total number of times M3UA LINK -


receieved messages

Maximum number of numb M3UA LINK -


received messages er

Minimum number of numb M3UA LINK -


received messages er

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1028


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 25 SG7000 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Average number of numb M3UA LINK -


received messages er

Bytes of receieved byte M3UA LINK -


messages

Duration of s M3UA LINK -


availability

Duration of s M3UA LINK -


unavailability

Maximum number of numb M3UA LINK MAX([Maximum number of


transmitted/received er transmitted messages],
messages [Maximum number of received
messages])

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

25.2.13 Total Messages Requiring Global Title Translation Report

Report Type
Simple Report

NE Type
SG7000

Object Type
SG7000NE

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1029


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 25 SG7000 Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Total Total messages numb SCCP global -


Message requiring global title er
s translation
Requirin
g Global Maximum messages numb SCCP global -
Title requiring global title er
Translati translation per
on second
Report UDT messages sent numb SCCP global -
er

Maximum number of numb SCCP global -


sent UDT messages er
per second

UDT messages numb SCCP global -


received er

Maximum number of numb SCCP global -


received UDT er
messages per second

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1030


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 26 SPS Performance Report

26 SPS Performance Report

About This Chapter

26.1 M3UA Link Report

26.2 SCCP globle Report

26.3 M3UA LinkSet Report

26.4 Link Report

26.5 M3UA ASSOAS Report

26.6 LinkSet Report

26.7 DSP Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1031


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 26 SPS Performance Report

26.1 M3UA Link Report


Report Type
Simple Report

NE Type
SPS

Object Type
M3UA Link

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

M3UA Bytes of receieved byte M3UA LINK -


Link message in one m3ua
association

Bytes of sent byte M3UA LINK -


message in one m3ua
association

Duration of m3ua s M3UA LINK -


association
availability

Duration of m3ua s M3UA LINK -


association
unavailability

Number of receieved times M3UA LINK -


message in one m3ua
association

Number of sent numb M3UA LINK -


message in one m3ua er
association

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1032


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 26 SPS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

26.2 SCCP globle Report


Report Type
Simple Report

NE Type
SPS

Object Type
SPSNE

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

SCCP Total messages numb SCCP global -


globle requiring global title er
translation

UDT messages numb SCCP global -


received er

UDT messages sent numb SCCP global -


er

UDTS messages numb SCCP global -


received er

UDTS messages sent numb SCCP global -


er

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1033


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 26 SPS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

26.3 M3UA LinkSet Report


Report Type
Simple Report

NE Type
SPS

Object Type
M3UA Link Set

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

M3UA Duration of m3ua s M3UA -


LinkSet association set LINKSET
unavailability

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

26.4 Link Report


Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1034


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 26 SPS Performance Report

NE Type
SPS

Object Type
Link

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

LINK Duration of SL s LINK -


unavailability(for
any reason)

Duration of link in s LINK -


the In-service state

MSUs discarded due numb LINK -


to SL congestion er

Number of SIF and numb LINK -


SIO octets received er

Number of SIF and numb LINK -


SIO octets er
transmitted

Number of message numb LINK -


signal units received er

Number of message numb LINK -


signal units er
transmitted

Number of negative times LINK -


ack. Received

Number of signal times LINK -


units received in
error

SL alignment or numb LINK -


proving failure er

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1035


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 26 SPS Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

26.5 M3UA ASSOAS Report


Report Type
Simple Report

NE Type
SPS

Object Type
M3UA ASSOAS

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

M3UA Duration of adjacent s M3UA -


ASSOAS AS inaccessible ASSOAS

Duration of route set s M3UA -


to a given destination ASSOAS
unavailability

Message discarded numb M3UA -


due to a routing data er ASSOAS
error

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1036


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 26 SPS Performance Report

26.6 LinkSet Report


Report Type
Simple Report

NE Type
SPS

Object Type
Link Set

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

LINKSE Duration of s LINKSET -


T unavailability of
signalling linkset

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

26.7 DSP Report


Report Type
Simple Report

NE Type
SPS

Object Type
DSP

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1037


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 26 SPS Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

DSP Duration of adjacent s DSP -


SP inaccessible

MSU discarded due numb DSP -


to a routing data error er

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1038


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

27 SPSV3 Performance Report

About This Chapter

27.1 CPU Usage Report

27.2 Diameter SCTP Send Load Busy Hour Report

27.3 Number of Sent Diameter SCTP Data Chunks Busy Hour Report

27.4 Diameter SCTP Load Measurement Report

27.5 Diameter SCTP Load Measurement Busy Hour Report

27.6 Diameter SCTP Receive Load Busy Hour Report

27.7 Number of Received Diameter SCTP Data Chunks Busy Hour Report

27.8 Diameter SCTP Bidirectional Load Busy Hour Report

27.9 Diameter Interface Message Measurement Report

27.10 Diameter Link Measurement Report

27.11 Diameter Message Measurement Report

27.12 Diameter Service Failure Measurement Report

27.13 M2PA Link Load Report

27.14 M2PA Link Load Busy Hour Report

27.15 M3UA Link Load Report

27.16 M3UA Link Load Busy Hour Report

27.17 STP Day Report

27.18 DSP Report

27.19 Link Load Report

27.20 Link Load Busy Hour Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1039


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

27.21 Linkset Load Report

27.22 Linkset Load Busy Hour Report

27.23 Link Usage and Availability Report

27.24 Total Messages Requiring Global Title Translation Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1040


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

27.1 CPU Usage Report


Report Type
Simple Report

NE Type
SPSV3

Object Type
Module

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

CPU Average CPU Usage % CPU Usage -


Usage Measuremen
Report t

Peak CPU Usage % CPU Usage -


Measuremen
t

Peak CPU Usage s CPU Usage -


Duration Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

27.2 Diameter SCTP Send Load Busy Hour Report


Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1041


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

NE Type
SPSV3

Object Type
Module

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Diameter Max Send Load % SCTP Load -


SCTP Measuremen
Send t
Load
Busy Number of Sent Data times SCTP Load -
Hour Chunks Measuremen
Report t

Number of Received times SCTP Load -


Data Chunks Measuremen
t

Receive Load % SCTP Load -


Measuremen
t

Bidirectional Load % SCTP Load [Send Load]+[Receive Load]


Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

27.3 Number of Sent Diameter SCTP Data Chunks Busy


Hour Report
Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1042


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

NE Type
SPSV3

Object Type
Module

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Number Max Number of Sent times SCTP Load -


of Sent Data Chunks Measuremen
Diameter t
SCTP
Data Number of Received times SCTP Load -
Chunks Data Chunks Measuremen
Busy t
Hour Send Load % SCTP Load -
Report Measuremen
t

Receive Load % SCTP Load -


Measuremen
t

Bidirectional Load % SCTP Load [Send Load]+[Receive Load]


Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

27.4 Diameter SCTP Load Measurement Report


Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1043


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

NE Type
SPSV3

Object Type
Module

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Diameter Number of Sent Data times SCTP Load -


SCTP Chunks Measuremen
Load t
Measure
ment Number of Received times SCTP Load -
Report Data Chunks Measuremen
t

Send Load % SCTP Load -


Measuremen
t

Receive Load % SCTP Load -


Measuremen
t

Bidirectional Load % SCTP Load [Send Load]+[Receive Load]


Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

27.5 Diameter SCTP Load Measurement Busy Hour Report


Report Type
Combined Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1044


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

Simple Report(s) List


l Number of Sent Diameter SCTP Data Chunks Busy Hour Report
l Number of Received Diameter SCTP Data Chunks Busy Hour Report
l Diameter SCTP Send Load Busy Hour Report
l Diameter SCTP Receive Load Busy Hour Report
l Diameter SCTP Bidirectional Load Busy Hour Report

Number of Sent Diameter SCTP Data Chunks Busy Hour Report

NE Type
SPSV3

Object Type
Module

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Number Max Number of Sent times SCTP Load -


of Sent Data Chunks Measuremen
Diameter t
SCTP
Data Number of Received times SCTP Load -
Chunks Data Chunks Measuremen
Busy t
Hour Send Load % SCTP Load -
Report Measuremen
t

Receive Load % SCTP Load -


Measuremen
t

Bidirectional Load % SCTP Load [Send Load]+[Receive Load]


Measuremen
t

Number of Received Diameter SCTP Data Chunks Busy Hour Report

NE Type
SPSV3

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1045


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

Object Type
Module

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Number Max Number of times SCTP Load -


of Received Data Measuremen
Received Chunks t
Diameter
SCTP Number of Sent Data times SCTP Load -
Data Chunks Measuremen
Chunks t
Busy Send Load % SCTP Load -
Hour Measuremen
Report t

Receive Load % SCTP Load -


Measuremen
t

Bidirectional Load % SCTP Load [Send Load]+[Receive Load]


Measuremen
t

Diameter SCTP Send Load Busy Hour Report

NE Type
SPSV3

Object Type
Module

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Diameter Max Send Load % SCTP Load -


SCTP Measuremen
Send t
Load

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1046


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Busy Number of Sent Data times SCTP Load -


Hour Chunks Measuremen
Report t

Number of Received times SCTP Load -


Data Chunks Measuremen
t

Receive Load % SCTP Load -


Measuremen
t

Bidirectional Load % SCTP Load [Send Load]+[Receive Load]


Measuremen
t

Diameter SCTP Receive Load Busy Hour Report

NE Type
SPSV3

Object Type
Module

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Diameter Max Receive Load % SCTP Load -


SCTP Measuremen
Receive t
Load
Busy Number of Sent Data times SCTP Load -
Hour Chunks Measuremen
Report t

Number of Received times SCTP Load -


Data Chunks Measuremen
t

Send Load % SCTP Load -


Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1047


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Bidirectional Load % SCTP Load [Send Load]+[Receive Load]


Measuremen
t

Diameter SCTP Bidirectional Load Busy Hour Report

NE Type
SPSV3

Object Type
Module

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Diameter Max Bidirectional % SCTP Load [Send Load]+[Receive Load]


SCTP Load Measuremen
Bidirecti t
onal
Load Number of Sent Data times SCTP Load -
Busy Chunks Measuremen
Hour t
Report Number of Received times SCTP Load -
Data Chunks Measuremen
t

Send Load % SCTP Load -


Measuremen
t

Receive Load % SCTP Load -


Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1048


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

27.6 Diameter SCTP Receive Load Busy Hour Report


Report Type
Simple Report

NE Type
SPSV3

Object Type
Module

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Diameter Max Receive Load % SCTP Load -


SCTP Measuremen
Receive t
Load
Busy Number of Sent Data times SCTP Load -
Hour Chunks Measuremen
Report t

Number of Received times SCTP Load -


Data Chunks Measuremen
t

Send Load % SCTP Load -


Measuremen
t

Bidirectional Load % SCTP Load [Send Load]+[Receive Load]


Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1049


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

27.7 Number of Received Diameter SCTP Data Chunks


Busy Hour Report
Report Type
Simple Report

NE Type
SPSV3

Object Type
Module

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Number Max Number of times SCTP Load -


of Received Data Measuremen
Received Chunks t
Diameter
SCTP Number of Sent Data times SCTP Load -
Data Chunks Measuremen
Chunks t
Busy Send Load % SCTP Load -
Hour Measuremen
Report t

Receive Load % SCTP Load -


Measuremen
t

Bidirectional Load % SCTP Load [Send Load]+[Receive Load]


Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1050


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

27.8 Diameter SCTP Bidirectional Load Busy Hour Report


Report Type
Simple Report

NE Type
SPSV3

Object Type
Module

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Diameter Max Bidirectional % SCTP Load [Send Load]+[Receive Load]


SCTP Load Measuremen
Bidirecti t
onal
Load Number of Sent Data times SCTP Load -
Busy Chunks Measuremen
Hour t
Report Number of Received times SCTP Load -
Data Chunks Measuremen
t

Send Load % SCTP Load -


Measuremen
t

Receive Load % SCTP Load -


Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1051


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

27.9 Diameter Interface Message Measurement Report


Report Type
Simple Report

NE Type
SPSV3

Object Type
Diameter Agent

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Diameter Number of S6a/S6d times Diameter -


Interface Application Interface
Message Received Request Message
Measure Messages Meaurement
ment
Report Number of S6a/S6d times Diameter -
Application Sent Interface
Request Messages Message
Meaurement

Number of S6a/S6d times Diameter -


Application Interface
Received Response Message
Messages Meaurement

Number of S6a/S6d times Diameter -


Application Sent Interface
Response Messages Message
Meaurement

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1052


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Number of S9 times Diameter -


Application Interface
Received Request Message
Messages Meaurement

Number of S9 times Diameter -


Application Sent Interface
Request Messages Message
Meaurement

Number of S9 times Diameter -


Application Interface
Received Response Message
Messages Meaurement

Number of S9 times Diameter -


Application Sent Interface
Response Messages Message
Meaurement

Number of Gx times Diameter -


Application Interface
Received Request Message
Messages Meaurement

Number of Gx times Diameter -


Application Sent Interface
Request Messages Message
Meaurement

Number of Gx times Diameter -


Application Interface
Received Response Message
Messages Meaurement

Number of Gx times Diameter -


Application Sent Interface
Response Messages Message
Meaurement

Number of Rx times Diameter -


Application Interface
Received Request Message
Messages Meaurement

Number of Rx times Diameter -


Application Sent Interface
Request Messages Message
Meaurement

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1053


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Number of Rx times Diameter -


Application Interface
Received Response Message
Messages Meaurement

Number of Rx times Diameter -


Application Sent Interface
Response Messages Message
Meaurement

Number of Gy/Ro times Diameter -


Application Interface
Received Request Message
Messages Meaurement

Number of Gy/Ro times Diameter -


Application Sent Interface
Request Messages Message
Meaurement

Number of Gy/Ro times Diameter -


Application Interface
Received Response Message
Messages Meaurement

Number of Gy/Ro times Diameter -


Application Sent Interface
Response Messages Message
Meaurement

Number of Other times Diameter -


Application Interface
Received Request Message
Messages Meaurement

Number of Other times Diameter -


Application Sent Interface
Request Messages Message
Meaurement

Number of Other times Diameter -


Application Interface
Received Response Message
Messages Meaurement

Number of Other times Diameter -


Application Sent Interface
Response Messages Message
Meaurement

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1054


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

27.10 Diameter Link Measurement Report


Report Type
Simple Report

NE Type
SPSV3

Object Type
Diameter Link

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Diameter Number of Received times Diameter -


Link Request Messages Link
Measure Measuremen
ment t
Report
Number of Sent times Diameter -
Request Messages Link
Measuremen
t

Number of Received times Diameter -


Response Messages Link
Measuremen
t

Number of Sent times Diameter -


Response Messages Link
Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1055


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Bytes of Received byte Diameter -


Request Messages Link
Measuremen
t

Bytes of Sent byte Diameter -


Request Messages Link
Measuremen
t

Bytes of Received byte Diameter -


Response Messages Link
Measuremen
t

Bytes of Sent byte Diameter -


Response Messages Link
Measuremen
t

SCTP Association times Diameter -


Retransmitted Times Link
Measuremen
t

SCTP Association times Diameter -


Send Buffer Link
Overflow Times Measuremen
t

SCTP Association times Diameter -


Receive Buffer Link
Overflow Times Measuremen
t

SCTP Association ms Diameter -


Average Link
Acknowledgement Measuremen
Delay t

SCTP Association ms Diameter -


Average Link
Acknowledgement Measuremen
Delay Deviation t

SCTP Association times Diameter -


Unavailable Times Link
Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1056


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

SCTP Association s Diameter -


Unavailable Link
Duration Measuremen
t

SCTP Association % Diameter -


Sent Buffer Usage Link
Measuremen
t

SCTP Association % Diameter -


Receive Buffer Link
Usage Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

27.11 Diameter Message Measurement Report


Report Type
Simple Report

NE Type
SPSV3

Object Type
Diameter Agent

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1057


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Diameter Number of Diameter packe Diameter -


Message Messages Used t/s Message
Measure Measuremen
ment t
Report
Number of Received times Diameter -
Diameter Messages Message
Measuremen
t

Number of Sent times Diameter -


Diameter Messages Message
Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

27.12 Diameter Service Failure Measurement Report


Report Type
Simple Report

NE Type
SPSV3

Object Type
Diameter Agent

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1058


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Diameter Number of Routed times Diameter -


Service Failure Messages Service
Failure Failure
Measure Measuremen
ment t
Report
Number of Rerouted times Diameter -
Messages Service
Failure
Measuremen
t

Number of times Diameter -


Retransmitted Service
Messages Failure
Measuremen
t

Number of Discard times Diameter -


Messages for Service
Congestion Failure
Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

27.13 M2PA Link Load Report


Report Type
Simple Report

NE Type
SPSV3

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1059


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

Object Type
M2PA Link

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

M2PA Number of Sent Data times M2PA Link -


Link Messages Measuremen
Load t
Report
Maximum Number numb M2PA Link -
of Sent Messages er Measuremen
t

Minimum Number of numb M2PA Link -


Sent Messages er Measuremen
t

Average Number of numb M2PA Link -


Sent Messages er Measuremen
t

Bytes of Sent Data byte M2PA Link -


Messages Measuremen
t

Number of Received times M2PA Link -


Data Messages Measuremen
t

Maximum Number numb M2PA Link -


of Received er Measuremen
Messages t

Minimum Number of numb M2PA Link -


Received Messages er Measuremen
t

Average Number of numb M2PA Link -


Received Messages er Measuremen
t

Bytes of Received byte M2PA Link -


Data Messages Measuremen
t

Available Duration s M2PA Link -


Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1060


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Unavailable s M2PA Link -


Duration Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

27.14 M2PA Link Load Busy Hour Report


Report Type
Reports to be queried based on the database

NE Type
SPSV3

Object Type
M2PA Link

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

M2PA Sent Message Time s M2PA Link -


Link Measuremen
Load t
Busy
Hour Maximum Sent numb M2PA Link -
Report Messages er Measuremen
t

Bytes of Sent byte M2PA Link -


Messages Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1061


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Received Message s M2PA Link -


Time Measuremen
t

Maximum Received numb M2PA Link -


Messages er Measuremen
t

Bytes of Received byte M2PA Link -


Messages Measuremen
t

Sent/Received s M2PA Link -


Message Time Measuremen
t

Maximum Sent/ numb M2PA Link -


Received Messages er Measuremen
t

Bidirectional s M2PA Link -


Message Time Measuremen
t

Maximum numb M2PA Link [Maximum Sent Messages]+


Bidirectional er Measuremen [Maximum Received
Messages t Messages]

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

27.15 M3UA Link Load Report


Report Type
Simple Report

NE Type
SPSV3

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1062


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

Object Type
M3UA Link

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

M3UA Number of Sent times M3UA Link -


Link Messages Measuremen
Load t
Report
Maximum Number numb M3UA Link -
of Sent Messages er Measuremen
t

Minimum Number of numb M3UA Link -


Sent Messages er Measuremen
t

Average Number of numb M3UA Link -


Sent Messages er Measuremen
t

Bytes of Sent byte M3UA Link -


Messages Measuremen
t

Number of Received times M3UA Link -


Messages Measuremen
t

Maximum Number numb M3UA Link -


of Received er Measuremen
Messages t

Minimum Number of numb M3UA Link -


Received Messages er Measuremen
t

Average Number of numb M3UA Link -


Received Messages er Measuremen
t

Bytes of Received byte M3UA Link -


Messages Measuremen
t

Available Duration s M3UA Link -


Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1063


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Unavailable s M3UA Link -


Duration Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

27.16 M3UA Link Load Busy Hour Report


Report Type
Reports to be queried based on the database

NE Type
SPSV3

Object Type
M3UA Link

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

M3UA Sent Message Time s M3UA Link -


Link Measuremen
Load t
Busy
Hour Maximum Sent numb M3UA Link -
Report Messages er Measuremen
t

Bytes of Sent byte M3UA Link -


Messages Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1064


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Received Message s M3UA Link -


Time Measuremen
t

Maximum Received numb M3UA Link -


Messages er Measuremen
t

Bytes of Received byte M3UA Link -


Messages Measuremen
t

Sent/Received s M3UA Link -


Message Time Measuremen
t

Maximum Sent/ numb M3UA Link -


Received Messages er Measuremen
t

Bidirectional s M3UA Link -


Message Time Measuremen
t

Maximum numb M3UA Link [Maximum Sent Messages]+


Bidirectional er Measuremen [Maximum Received
Messages t Messages]

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

27.17 STP Day Report


Report Type
Combined Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1065


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

Simple Report(s) List


l M2PA Link Load Report
l M3UA Link Load Report
l Total Messages Requiring Global Title Translation Report
l CPU Usage Report
l Link Load Report
l Linkset Load Report
l Link Usage and Availability Report
l DSP Report

M2PA Link Load Report

NE Type
SPSV3

Object Type
M2PA Link

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

M2PA Number of Sent Data times M2PA Link -


Link Messages Measuremen
Load t
Report
Maximum Number numb M2PA Link -
of Sent Messages er Measuremen
t

Minimum Number of numb M2PA Link -


Sent Messages er Measuremen
t

Average Number of numb M2PA Link -


Sent Messages er Measuremen
t

Bytes of Sent Data byte M2PA Link -


Messages Measuremen
t

Number of Received times M2PA Link -


Data Messages Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1066


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Maximum Number numb M2PA Link -


of Received er Measuremen
Messages t

Minimum Number of numb M2PA Link -


Received Messages er Measuremen
t

Average Number of numb M2PA Link -


Received Messages er Measuremen
t

Bytes of Received byte M2PA Link -


Data Messages Measuremen
t

Available Duration s M2PA Link -


Measuremen
t

Unavailable s M2PA Link -


Duration Measuremen
t

M3UA Link Load Report

NE Type
SPSV3

Object Type
M3UA Link

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

M3UA Number of Sent times M3UA Link -


Link Messages Measuremen
Load t
Report
Maximum Number numb M3UA Link -
of Sent Messages er Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1067


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Minimum Number of numb M3UA Link -


Sent Messages er Measuremen
t

Average Number of numb M3UA Link -


Sent Messages er Measuremen
t

Bytes of Sent byte M3UA Link -


Messages Measuremen
t

Number of Received times M3UA Link -


Messages Measuremen
t

Maximum Number numb M3UA Link -


of Received er Measuremen
Messages t

Minimum Number of numb M3UA Link -


Received Messages er Measuremen
t

Average Number of numb M3UA Link -


Received Messages er Measuremen
t

Bytes of Received byte M3UA Link -


Messages Measuremen
t

Available Duration s M3UA Link -


Measuremen
t

Unavailable s M3UA Link -


Duration Measuremen
t

Total Messages Requiring Global Title Translation Report

NE Type
SPSV3

Object Type
SPSV3

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1068


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Total Total messages times GT Translate -


Message requiring global title Information
s translation Measuremen
Requirin t
g Global
Title Total messages numb GT Translate -
Translati requiring global title er Information
on translation Measuremen
Report (Maximum/second) t

Number of Sent UDT times GT Translate -


Messages Information
Measuremen
t

Number of Sent UDT numb GT Translate -


Messages er Information
(Maximum/second) Measuremen
t

Number of Received times GT Translate -


UDT Messages Information
Measuremen
t

Number of Received numb GT Translate -


UDT Messages er Information
(Maximum/second) Measuremen
t

CPU Usage Report

NE Type
SPSV3

Object Type
Module

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1069


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

CPU Average CPU Usage % CPU Usage -


Usage Measuremen
Report t

Peak CPU Usage % CPU Usage -


Measuremen
t

Peak CPU Usage s CPU Usage -


Duration Measuremen
t

Link Load Report

NE Type
SPSV3

Object Type
Link

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Link Number of SIF And byte MTP Link -


Load SIO Octets Measuremen
Report Transmitted t

Number of Message times MTP Link -


Signal Units Measuremen
Transmitted t

Maximum Erl MTP Link -


Transmitted Load Measuremen
t

Average Transmitted Erl MTP Link -


Load Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1070


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Number of SIF And byte MTP Link -


SIO Octets Received Measuremen
t

Number of Message times MTP Link -


Signal Units Measuremen
Received t

Maximum Received Erl MTP Link -


Load Measuremen
t

Average Received Erl MTP Link -


Load Measuremen
t

Average Transmitted Erl MTP Link [Average Transmitted Load]+


and Received Load Measuremen [Average Received Load]
t

Number of SIF And None MTP Link [Number of SIF And SIO
SIO Octets Measuremen Octets Transmitted]/[Number
Transmitted per t of Message Signal Units
MSU Transmitted]

Number of SIF And None MTP Link [Number of SIF And SIO
SIO Octets Received Measuremen Octets Received]/[Number of
per MSU t Message Signal Units
Received]

Duration of s MTP Link -


Availability of Link Measuremen
t

Maximum Received numb MTP Link [Number of Message Signal


MSU per sencond er Measuremen Units Received]/{GP}/60
t

Maximum numb MTP Link [Number of Message Signal


Transmitted MSU er Measuremen Units Transmitted]/{GP}/60
per sencond t

Number of Signal times MTP Link -


Units Received in Measuremen
Error t

Maximum Erl MTP Link MAX{[Maximum Transmitted


Transmitted/ Measuremen Load],[Maximum Received
Received Load t Load]}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1071


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

Linkset Load Report

Report Type
Simple Report

NE Type
SPSV3

Object Type
MTP Linkset

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Linkset Transmitted Load Erl MTP Link -


Load Measuremen
Report t

Received Load Erl MTP Link -


Measuremen
t

Transmitted and Erl MTP Link [Transmitted Load]+[Received


Received Load Measuremen Load]
t

Link Usage and Availability Report

Report Type
Simple Report

NE Type
SPSV3

Object Type
Link

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1072


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Link Average Transmitted Erl MTP Link -


Usage Load Measuremen
and t
Availabil
ity Average Received Erl MTP Link -
Report Load Measuremen
t

Number of Message times MTP Link -


Signal Units Measuremen
Transmitted t

Number of Message times MTP Link -


Signal Units Measuremen
Received t

Maximum numb MTP Link [Number of Message Signal


Transmitted MSU er Measuremen Units Transmitted]/{GP}/60
per sencond t

Maximum Received numb MTP Link [Number of Message Signal


MSU per sencond er Measuremen Units Received]/{GP}/60
t

Number of SIF And byte MTP Link -


SIO Octets Measuremen
Transmitted t

Number of SIF And byte MTP Link -


SIO Octets Received Measuremen
t

Duration of s MTP Link -


Availability of Link Measuremen
t

Duration of s MTP Link -


Unavailability of Measuremen
Link t

Link Usage % MTP Link -


Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1073


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

DSP Report

Report Type
Simple Report

NE Type
SPSV3

Object Type
MTP Destination Signaling Point

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

DSP Destination times MTP -


Report Signaling Point Destination
Inaccessible Signaling
Point
Measuremen
t

Duration of s MTP -
Destination Destination
Signaling Point Signaling
Inaccessible Point
Measuremen
t

MSU Discarded Due times MTP -


to a Routing Data Destination
Error Signaling
Point
Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1074


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

27.18 DSP Report


Report Type
Simple Report

NE Type
SPSV3

Object Type
MTP Destination Signaling Point

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

DSP Destination times MTP -


Report Signaling Point Destination
Inaccessible Signaling
Point
Measuremen
t

Duration of s MTP -
Destination Destination
Signaling Point Signaling
Inaccessible Point
Measuremen
t

MSU Discarded Due times MTP -


to a Routing Data Destination
Error Signaling
Point
Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1075


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

27.19 Link Load Report


Report Type
Simple Report

NE Type
SPSV3

Object Type
Link

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Link Number of SIF And byte MTP Link -


Load SIO Octets Measuremen
Report Transmitted t

Number of Message times MTP Link -


Signal Units Measuremen
Transmitted t

Maximum Erl MTP Link -


Transmitted Load Measuremen
t

Average Transmitted Erl MTP Link -


Load Measuremen
t

Number of SIF And byte MTP Link -


SIO Octets Received Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1076


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Number of Message times MTP Link -


Signal Units Measuremen
Received t

Maximum Received Erl MTP Link -


Load Measuremen
t

Average Received Erl MTP Link -


Load Measuremen
t

Average Transmitted Erl MTP Link [Average Transmitted Load]+


and Received Load Measuremen [Average Received Load]
t

Number of SIF And None MTP Link [Number of SIF And SIO
SIO Octets Measuremen Octets Transmitted]/[Number
Transmitted per t of Message Signal Units
MSU Transmitted]

Number of SIF And None MTP Link [Number of SIF And SIO
SIO Octets Received Measuremen Octets Received]/[Number of
per MSU t Message Signal Units
Received]

Duration of s MTP Link -


Availability of Link Measuremen
t

Maximum Received numb MTP Link [Number of Message Signal


MSU per sencond er Measuremen Units Received]/{GP}/60
t

Maximum numb MTP Link [Number of Message Signal


Transmitted MSU er Measuremen Units Transmitted]/{GP}/60
per sencond t

Number of Signal times MTP Link -


Units Received in Measuremen
Error t

Maximum Erl MTP Link MAX{[Maximum Transmitted


Transmitted/ Measuremen Load],[Maximum Received
Received Load t Load]}

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1077


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

27.20 Link Load Busy Hour Report


Report Type
Simple Report

NE Type
SPSV3

Object Type
Link

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Link Maximum Received Erl MTP Link -


Load Load Measuremen
Busy t
Hour
Report Received Load Time None None -

Maximum Erl MTP Link -


Transmitted Load Measuremen
t

Transmitted Load None None -


Time

Maximum Erl MTP Link [Maximum Received Load]+


Bidirectional Load Measuremen [Maximum Transmitted Load]
t

Bidirectional Load None None -


Time

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1078


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

27.21 Linkset Load Report


Report Type
Simple Report

NE Type
SPSV3

Object Type
MTP Linkset

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Linkset Transmitted Load Erl MTP Link -


Load Measuremen
Report t

Received Load Erl MTP Link -


Measuremen
t

Transmitted and Erl MTP Link [Transmitted Load]+[Received


Received Load Measuremen Load]
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1079


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

27.22 Linkset Load Busy Hour Report


Report Type
Simple Report

NE Type
SPSV3

Object Type
MTP Linkset

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Linkset Maximum Received Erl MTP Link -


Load Load Measuremen
Busy t
Hour
Report Received Load Time None None -

Maximum Erl MTP Link -


Transmitted Load Measuremen
t

Transmitted Load None None -


Time

Maximum Erl MTP Link [Maximum Received Load]+


Bidirectional Load Measuremen [Maximum Transmitted Load]
t

Bidirectional Load None None -


Time

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1080


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

27.23 Link Usage and Availability Report


Report Type
Simple Report

NE Type
SPSV3

Object Type
Link

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Link Average Transmitted Erl MTP Link -


Usage Load Measuremen
and t
Availabil
ity Average Received Erl MTP Link -
Report Load Measuremen
t

Number of Message times MTP Link -


Signal Units Measuremen
Transmitted t

Number of Message times MTP Link -


Signal Units Measuremen
Received t

Maximum numb MTP Link [Number of Message Signal


Transmitted MSU er Measuremen Units Transmitted]/{GP}/60
per sencond t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1081


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Maximum Received numb MTP Link [Number of Message Signal


MSU per sencond er Measuremen Units Received]/{GP}/60
t

Number of SIF And byte MTP Link -


SIO Octets Measuremen
Transmitted t

Number of SIF And byte MTP Link -


SIO Octets Received Measuremen
t

Duration of s MTP Link -


Availability of Link Measuremen
t

Duration of s MTP Link -


Unavailability of Measuremen
Link t

Link Usage % MTP Link -


Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

27.24 Total Messages Requiring Global Title Translation


Report
Report Type
Simple Report

NE Type
SPSV3

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1082


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 27 SPSV3 Performance Report

Object Type
SPSV3

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Total Total messages times GT Translate -


Message requiring global title Information
s translation Measuremen
Requirin t
g Global
Title Total messages numb GT Translate -
Translati requiring global title er Information
on translation Measuremen
Report (Maximum/second) t

Number of Sent UDT times GT Translate -


Messages Information
Measuremen
t

Number of Sent UDT numb GT Translate -


Messages er Information
(Maximum/second) Measuremen
t

Number of Received times GT Translate -


UDT Messages Information
Measuremen
t

Number of Received numb GT Translate -


UDT Messages er Information
(Maximum/second) Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1083


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 28 VoLTE KPI Performance Report

28 VoLTE KPI Performance Report

About This Chapter

28.1 VoLTE KPI Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1084


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 28 VoLTE KPI Performance Report

28.1 VoLTE KPI Report


Report Type
Simple Report

NE Type
Whole Network

Object Type
Whole Network

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

VoLTE Register IN times ATS Register -


KPI Subscriber Number Data
Report Measuremen
t

MO-SMS Successful % IP-SM-GW -


Rate Measuremen
t

MT-SMS Successful % IP-SM-GW -


Rate Measuremen
t

Number of times S-CSCF -


Registered Users Access Type
User
Measuremen
t

Rate of Successful % S-CSCF -


Initial Registrations Access Type
and Office
Registration
Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1085


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 28 VoLTE KPI Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Rate of Successful % S-CSCF ([Number of S-CSCF


Registrations (with Session Successful Initial
Subscriber Cause) Unrelated Registrations]+[Number of S-
Measuremen CSCF Successful
t Deregistrations]+[Number of
S-CSCF Successful Re-
registrations]+[003 Number of
SIP Operation Errors]+[004
Number of Invalid IMPU
Errors]+[008 Number of
Authentication Algorithm
Errors]+[017 Number of
Register and Deregister
Requests Not Match Errors]
+[018 Number of Subsequent
Register with Changed Call-ID
Errors]+[025 Number of
Authentication Failures]+[026
Number of Invalid Subsequent
Register Messages]+[030
Number of Deregisters
Initiated by Unregistered
Users])/([Number of S-CSCF
Initial Registration Attempts]+
[Number of S-CSCF
Deregistration Attempts]+
[Number of S-CSCF Re-
registration Attempts])*{100}

Rate of Successful % S-CSCF -


Re-registrations Access Type
and Office
Registration
Measuremen
t

Rate of Successful % S-CSCF -


Authentication Session
Attempts Unrelated
Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1086


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 28 VoLTE KPI Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Rate of Responses % S-CSCF -


(with Subscriber Access Type
Cause) to MO MO
Incoming Sessions Incoming
Session
Measuremen
t

Rate of Responses % S-CSCF -


(with Subscriber Access Type
Cause) to MO MO
Outgoing Sessions Outgoing
Session
Measuremen
t

Rate of Responses % S-CSCF -


(with Subscriber Access Type
Cause) to MT MT
Incoming Sessions Incoming
Session
Measuremen
t

Rate of Responses % S-CSCF -


(with Subscriber Access Type
Cause) to MT MT
Outgoing Sessions Outgoing
Session
Measuremen
t

MO Incoming % S-CSCF -
Session Answer Rate Access Type
MO
Incoming
Session
Measuremen
t

MO Outgoing % S-CSCF -
Session Answer Rate Access Type
MO
Outgoing
Session
Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1087


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 28 VoLTE KPI Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

MT Incoming % S-CSCF -
Session Answer Rate Access Type
MT
Incoming
Session
Measuremen
t

MT Outgoing % S-CSCF -
Session Answer Rate Access Type
MT
Outgoing
Session
Measuremen
t

Mean Call Duration s S-CSCF -


Access Type
Mean
Duration
from
Answering to
Release
Measuremen
t

MO-SMS through % Short [LTE SMMO Success Times]/


SGs Success Rate Message [LTE SMMO Attempts]*
Service {100}

MT-SMS through % Short [LTE SMMT Success Times]/


SGs Success Rate Message [LTE SMMT Attempts]*{100}
Service

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1088


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 28 VoLTE KPI Performance Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

eSRVCC Success % 2G eSRVCC [Number of 2G eSRVCC


Rate(4G to 2G) Service Services with Successful Radio
Measuremen Handovers and ISTs]*{100}/
t ([Number of Requested 2G
Intra-MSC eSRVCC
Handovers]+[Number of
Requested 2G Inter-MSC
eSRVCC Handovers]-
[Number of Cancelled 2G
eSRVCC Services Before
SRVCC IWF Sends SRVCC
PS to CS Response Messages]-
[Number of Cancelled 2G
eSRVCC Services After
SRVCC IWF Sends SRVCC
PS to CS Response Messages])

eSRVCC Success % 3G eSRVCC [Number of 3G eSRVCC


Rate(4G to 3G) Service Services with Successful Radio
Measuremen Handovers and ISTs]*{100}/
t ([Number of Requested 3G
Intra-MSC eSRVCC
Handovers]+[Number of
Requested 3G Inter-MSC
eSRVCC Handovers]-
[Number of Cancelled 3G
eSRVCC Services Before
SRVCC IWF Sends SRVCC
PS to CS Response Messages]-
[Number of Cancelled 3G
eSRVCC Services After
SRVCC IWF Sends SRVCC
PS to CS Response Messages])

eSRVCC Session % eSRVCC -


Transfer Success Statistics
Rate

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1089


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 28 VoLTE KPI Performance Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1090


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 29 2G Network Capacity Analysis Report

29 2G Network Capacity Analysis Report

About This Chapter

29.1 BSC

29.2 BTS

29.3 Cell

29.4 EGPU/EXPU(CP Subsystem Detail Report)

29.5 EGPU/EXPU(CS UP Subsystem Detail Report)

29.6 EGPU/EXPU(PS UP Subsystem Detail Report)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1091


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 29 2G Network Capacity Analysis Report

29.1 BSC

29.1.1 A Interface

A Interface(IP, Same User and Signaling Interfaces)

Report Type
Simple Report

NE Type
2GBSC

Object Type
FEGE

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

A Mean Receive % FE/GE -


Interface Utilization Rate of A Ethernet Port
(IP, Interface User Plane Measuremen
Same (Same Interface of t
User and User Plane and
Signaling Signaling Plane)
Interface
s) Mean Transmit % FE/GE -
Utilization Rate of A Ethernet Port
Interface User Plane Measuremen
(Same Interface of t
User Plane and
Signaling Plane)

Peak Receive % FE/GE -


Utilization Rate of A Ethernet Port
Interface User Plane Measuremen
(Same Interface of t
User Plane and
Signaling Plane)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1092


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 29 2G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Peak Transmit % FE/GE -


Utilization Rate of A Ethernet Port
Interface User Plane Measuremen
(Same Interface of t
User Plane and
Signaling Plane)

Highest Transmit % FE/GE -


Utilization Rate of A Ethernet Port
Interface Signaling Measuremen
Plane (Same t
Interface of User
Plane and Signaling
Plane)

Lowest Transmit % FE/GE -


Utilization Rate of A Ethernet Port
Interface Signaling Measuremen
Plane (Same t
Interface of User
Plane and Signaling
Plane)

Mean Transmit % FE/GE -


Utilization Rate of A Ethernet Port
Interface Signaling Measuremen
Plane (Same t
Interface of User
Plane and Signaling
Plane)

Highest Receive % FE/GE -


Utilization Rate of A Ethernet Port
Interface Signaling Measuremen
Plane (Same t
Interface of User
Plane and Signaling
Plane)

Lowest Receive % FE/GE -


Utilization Rate of A Ethernet Port
Interface Signaling Measuremen
Plane (Same t
Interface of User
Plane and Signaling
Plane)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1093


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 29 2G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Mean Receive % FE/GE -


Utilization Rate of A Ethernet Port
Interface Signaling Measuremen
Plane (Same t
Interface of User
Plane and Signaling
Plane)

Highest Receive % FE/GE -


Utilization Rate of A Ethernet Port
Interface (Same Measuremen
Interface of User t
Plane and Signaling
Plane)

Lowest Receive % FE/GE -


Utilization Rate of A Ethernet Port
Interface (Same Measuremen
Interface of User t
Plane and Signaling
Plane)

Mean Receive % FE/GE -


Utilization Rate of A Ethernet Port
Interface (Same Measuremen
Interface of User t
Plane and Signaling
Plane)

Highest Transmit % FE/GE -


Utilization Rate of A Ethernet Port
Interface (Same Measuremen
Interface of User t
Plane and Signaling
Plane)

Lowest Transmit % FE/GE -


Utilization Rate of A Ethernet Port
Interface (Same Measuremen
Interface of User t
Plane and Signaling
Plane)

Mean Transmit % FE/GE -


Utilization Rate of A Ethernet Port
Interface (Same Measuremen
Interface of User t
Plane and Signaling
Plane)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1094


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 29 2G Network Capacity Analysis Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

A Interface Signaling Plane(IP, Different User and Signaling Interfaces)

Report Type
Simple Report

NE Type
2GBSC

Object Type
FEGE

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

A Highest Receive % FE/GE -


Interface Utilization Rate of A Ethernet Port
Signaling Interface Signaling Measuremen
Plane(IP, Plane (Different t
Different Interfaces of User
User and Plane and Signaling
Signaling Plane)
Interface
s) Lowest Receive % FE/GE -
Utilization Rate of A Ethernet Port
Interface Signaling Measuremen
Plane (Different t
Interfaces of User
Plane and Signaling
Plane)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1095


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 29 2G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Mean Receive % FE/GE -


Utilization Rate of A Ethernet Port
Interface Signaling Measuremen
Plane (Different t
Interfaces of User
Plane and Signaling
Plane)

Highest Transmit % FE/GE -


Utilization Rate of A Ethernet Port
Interface Signaling Measuremen
Plane (Different t
Interfaces of User
Plane and Signaling
Plane)

Lowest Transmit % FE/GE -


Utilization Rate of A Ethernet Port
Interface Signaling Measuremen
Plane (Different t
Interfaces of User
Plane and Signaling
Plane)

Mean Transmit % FE/GE -


Utilization Rate of A Ethernet Port
Interface Signaling Measuremen
Plane (Different t
Interfaces of User
Plane and Signaling
Plane)

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

A Interface Signaling Plane(IP)

Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1096


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 29 2G Network Capacity Analysis Report

NE Type
2GBSC

Object Type
GBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

A A Interface Signaling kbit/s TRX -


Interface Plane DL Measuremen
Signaling Throughput (IP) t per BSC
Plane(IP)
A Interface Signaling kbit/s TRX -
Plane UL Measuremen
Throughput (IP) t per BSC

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

A Interface Signaling Plane(TDM)

Report Type
Simple Report

NE Type
2GBSC

Object Type
MTP3LNK

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1097


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 29 2G Network Capacity Analysis Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

A A Interface Signaling % MTP2 Link -


Interface Resource Transmit Measuremen
Signaling Utilization Rate t
Plane (TDM)
(TDM)
A Interface Signaling % MTP2 Link -
Resource Receive Measuremen
Utilization Rate t
(TDM)

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

A Interface User Plane(IP, Different User and Signaling Interfaces)

Report Type
Simple Report

NE Type
2GBSC

Object Type
FEGE

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1098


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 29 2G Network Capacity Analysis Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

A Highest Receive % FE/GE -


Interface Utilization Rate of A Ethernet Port
User Interface User Plane Measuremen
Plane(IP, (Different Interfaces t
Different of User Plane and
User and Signaling Plane)
Signaling
Interface Lowest Receive % FE/GE -
s) Utilization Rate of A Ethernet Port
Interface User Plane Measuremen
(Different Interfaces t
of User Plane and
Signaling Plane)

Mean Receive % FE/GE -


Utilization Rate of A Ethernet Port
Interface User Plane Measuremen
(Different Interfaces t
of User Plane and
Signaling Plane)

Highest Transmit % FE/GE -


Utilization Rate of A Ethernet Port
Interface User Plane Measuremen
(Different Interfaces t
of User Plane and
Signaling Plane)

Lowest Transmit % FE/GE -


Utilization Rate of A Ethernet Port
Interface User Plane Measuremen
(Different Interfaces t
of User Plane and
Signaling Plane)

Mean Transmit % FE/GE -


Utilization Rate of A Ethernet Port
Interface User Plane Measuremen
(Different Interfaces t
of User Plane and
Signaling Plane)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1099


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 29 2G Network Capacity Analysis Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

A Interface User Plane(IP POOL)

Report Type
Simple Report

NE Type
2GBSC

Object Type
QAAL2 Node

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

A A Interface User % Transmission -


Interface Plane Resource
User Utilization_DL (IP Pool
Plane(IP POOL) Adjacent
POOL) Node User-
Plane Traffic
Measuremen
t

A Interface User kbit/s Transmission -


Plane Resource
Throughput_DL (IP Pool
POOL) Adjacent
Node User-
Plane Traffic
Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1100


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 29 2G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

A Interface User kbit/s Measuremen -


Plane t related to
BandWidth_DL(IP QAAL2 CM
POOL) Parameter_G
SM

A Interface User % Transmission -


Plane Resource
Utilization_UL (IP Pool
POOL) Adjacent
Node User-
Plane Traffic
Measuremen
t

A Interface User kbit/s Transmission -


Plane Resource
Throughput_UL (IP Pool
POOL) Adjacent
Node User-
Plane Traffic
Measuremen
t

A Interface User kbit/s Measuremen -


Plane t related to
BandWidth_UL(IP QAAL2 CM
POOL) Parameter_G
SM

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

A Interface User Plane(TDM)

Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1101


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 29 2G Network Capacity Analysis Report

NE Type
2GBSC

Object Type
DPC Group

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

A A Interface Resource % A-Interface -


Interface Utilization Rate Circuit
User (TDM) Measuremen
Plane t
(TDM)

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

29.1.2 Ater Interface

Ater Interface(TDM)

Report Type
Simple Report

NE Type
2GBSC

Object Type
GBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1102


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 29 2G Network Capacity Analysis Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Ater Ater Interface % Ater -


Interface Resource Utilization Interface
(TDM) Rate (TDM) Circuit
Measuremen
t per TC
Subrack

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

29.1.3 Board

CS Board Resource(BSC6900GSM)

Report Type
Simple Report

NE Type
2GBSC

Object Type
GBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

CS Board CS Board Resource % TRX -


Resource Utilization Measuremen
Rate_BSC6900 t per BSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1103


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 29 2G Network Capacity Analysis Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

CS Board Resource(BSC6910GSM)

Report Type
Simple Report

NE Type
2GBSC

Object Type
GBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

CS Board CS Board Resource % Access -


Resource Utilization Measuremen
Rate_BSC6910 t per BSC

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

DPU(BSC6900GSM)

Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1104


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 29 2G Network Capacity Analysis Report

NE Type
2GBSC

Object Type
Board

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

DPU DPU Board CPU % DPU -


Mean Utilization Subsystem
Rate Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

EGPU/EXPU(CP)(BSC6910GSM)

Report Type
Simple Report

NE Type
2GBSC

Object Type
SubSys Virtual Group

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1105


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 29 2G Network Capacity Analysis Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

EGPU/ EGPU/EXPU Board % Subsystem -


EXPU CP CPU Utilization Measuremen
(CP) Rate (Mean)_GSM t

EGPU/EXPU Board None Measuremen -


CP Subsystem t related to
Number_GSM EGPU
Subsystem
Configuratio
n

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

EGPU/EXPU(CS UP)(BSC6910GSM)

Report Type
Simple Report

NE Type
2GBSC

Object Type
SubSys Virtual Group

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1106


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 29 2G Network Capacity Analysis Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

EGPU/ EGPU/EXPU Board % Subsystem -


EXPU CS UP CPU Measuremen
(CS UP) Utilization Rate t
(Mean)_GSM

EGPU/EXPU Board None Measuremen -


CS UP Subsystem t related to
Number_GSM EGPU
Subsystem
Configuratio
n

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

EGPU/EXPU(PS UP)(BSC6910GSM)

Report Type
Simple Report

NE Type
2GBSC

Object Type
SubSys Virtual Group

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1107


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 29 2G Network Capacity Analysis Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

EGPU/ EGPU/EXPU Board % Subsystem -


EXPU PS UP CPU Measuremen
(PS UP) Utilization Rate t
(Mean)_GSM

EGPU/EXPU Board None Measuremen -


PS UP Subsystem t related to
Number_GSM EGPU
Subsystem
Configuratio
n

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

INT(BSC6900GSM)

Report Type
Simple Report

NE Type
2GBSC

Object Type
Board

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1108


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 29 2G Network Capacity Analysis Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

INT INT Board CPU % Interface -


Mean Utilization Board
Rate Subsystem
Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

INT(Signaling)(BSC6910GSM)

Report Type
Simple Report

NE Type
2GBSC

Object Type
CPU

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

INT INT Board Signaling % CPU -


(Signalin Plane Utilization Measuremen
g) Rate (Mean)_GSM t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1109


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 29 2G Network Capacity Analysis Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

INT(User)(BSC6910GSM)

Report Type
Simple Report

NE Type
2GBSC

Object Type
Board

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

INT INT Board User % Interface -


(User) Plane Utilization Board
Rate (Mean)_GSM Subsystem
Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1110


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 29 2G Network Capacity Analysis Report

PS Board Resource(BSC6910GSM)

Report Type
Simple Report

NE Type
2GBSC

Object Type
GBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

PS Board PS Board Resource % PS -


Resource Utilization Capability
Rate_BSC6910 Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

PS Board Resource(BSC6900GSM)

Report Type
Simple Report

NE Type
2GBSC

Object Type
GBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1111


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 29 2G Network Capacity Analysis Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

PS Board PS Board Resource % PDCH -


Resource Utilizable Resource
Rate_BSC6900 Capability
Measuremen
t per BSC

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

RMP(BSC6910GSM)

Report Type
Simple Report

NE Type
2GBSC

Object Type
CPU

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

RMP RMP Board CPU % CPU -


Utilization Rate Measuremen
(Mean)_GSM t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1112


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 29 2G Network Capacity Analysis Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

SCU(BSC6910GSM)

Report Type
Simple Report

NE Type
2GBSC

Object Type
CPU

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

SCU SCU Board CPU % CPU -


Utilization Rate Measuremen
(Mean) t
_BSC6910_GSM

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

SCU(BSC6900GSM)

Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1113


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 29 2G Network Capacity Analysis Report

NE Type
2GBSC

Object Type
Board

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

SCU SCU Board CPU % SCU -


Mean Utilization Subsystem
Rate Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

SCU Tx Ability(BSC6900GSM)

Report Type
Simple Report

NE Type
2GBSC

Object Type
Inter-Subrack Traffic Object

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1114


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 29 2G Network Capacity Analysis Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

SCU Tx SCU Send Traffic % Inter- -


Ability Utilization Rate Subrack
(Mean)_GSM Traffic
Measuremen
t

SCU Send Traffic kbit/s Inter- -


(Mean)_GSM Subrack
Traffic
Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

SCU Tx Ability(BSC6910GSM)

Report Type
Simple Report

NE Type
2GBSC

Object Type
Inter-Subrack Traffic Object

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1115


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 29 2G Network Capacity Analysis Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

SCU Tx SCU Send Traffic % Inter- -


Ability Utilization Rate Subrack
(Mean)_GSM Traffic
Measuremen
t

SCU Send Traffic kbit/s Inter- -


(Mean)_GSM Subrack
Traffic
Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

TNU(BSC6900GSM)

Report Type
Simple Report

NE Type
2GBSC

Object Type
Board

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1116


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 29 2G Network Capacity Analysis Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

TNU TNU Board CPU % TNU -


Mean Utilization Measuremen
Rate t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

XPU(BSC6900GSM)

Report Type
Simple Report

NE Type
2GBSC

Object Type
Board

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

XPU XPU Board CPU % XPU -


Mean Utilization Subsystem
Rate Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1117


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 29 2G Network Capacity Analysis Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

29.1.4 Gb

GB over FR

Report Type
Simple Report

NE Type
2GBSC

Object Type
BC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

GB over GB Downlink BC % BC -
FR Utilization Rate (GB Measuremen
over FR) t

GB Downlink BC None BC -
Overload Number Measuremen
(GB over FR) t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1118


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 29 2G Network Capacity Analysis Report

GB over IP

Report Type
Simple Report

NE Type
2GBSC

Object Type
GBSC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

GB over GB over IP NSVL % NSVL -


IP Mean Receive Capability
Availability Rate Measuremen
(GB over IP) t per BSC

GB over IP NSVL % NSVL -


Peak Receive Capability
Availability Rate Measuremen
(GB over IP) t per BSC

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

29.2 BTS

29.2.1 Abis Interface(IP over E1)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1119


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 29 2G Network Capacity Analysis Report

Abis MLPPP(IP over E1)

Report Type
Simple Report

NE Type
2GBSC

Object Type
BTS

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Abis Abis MLPPP % BTS -


MLPPP Forward Utilization FlexAbis
(IP over Rate (IP) Measuremen
E1) t per BTS

Abis MLPPP % BTS -


Backward Utilization FlexAbis
Rate (IP) Measuremen
t per BTS

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Abis PPP(IP over E1)

Report Type
Simple Report

NE Type
2GBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1120


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 29 2G Network Capacity Analysis Report

Object Type
PPP

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Abis PPP Abis PPP Link % PPP Link -


(IP over Forward Utilization Measuremen
E1) Rate (IP) t

Abis PPP Link % PPP Link -


Backward Utilization Measuremen
Rate (IP) t

Abis PPP Link % PPP Link -


Forward Peak Measuremen
Utilization Rate (IP) t

Abis PPP Link % PPP Link -


Backward Peak Measuremen
Utilization Rate (IP) t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

29.2.2 Abis Interface(IP over FE/GE)

Abis Interface User Plane(IP over FE/GE, no Logic Port)

Report Type
Simple Report

NE Type
2GBSC

Object Type
BTS

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1121


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 29 2G Network Capacity Analysis Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Abis Abis Forward % BTS -


Interface Utilization Rate (IP) FlexAbis
User Measuremen
Plane(IP t per BTS
over FE/
GE, no Abis Backward % BTS -
Logic Utilization Rate (IP) FlexAbis
Port) Measuremen
t per BTS

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Abis IP Logic Port(IP over FE/GE)

Report Type
Simple Report

NE Type
2GBSC

Object Type
BTS

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Abis IP Abis IP Logic Port % BTS -


Logic Utilization Rate (IP) FlexAbis
Port(IP Measuremen
t per BTS

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1122


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 29 2G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

over FE/ Abis IP Logic Port % BTS -


GE) Peak Utilization Rate FlexAbis
(IP) Measuremen
t per BTS

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

29.2.3 Abis Interface(TDM)

Abis(TDM)

Report Type
Simple Report

NE Type
2GBSC

Object Type
BTS

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Abis Abis Timeslot % Utilization of -


(TDM) Utilization Rate BTS
(TDM) Timeslots

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1123


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 29 2G Network Capacity Analysis Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

29.3 Cell

29.3.1 Um(CS)

Um(CS)

Report Type
Simple Report

NE Type
2GBSC

Object Type
GCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Um(CS) TCH Traffic Erl KPI -


Measuremen
t per Cell

TCHH Traffic Erl KPI -


Measuremen
t per Cell

TCHF Traffic Erl KPI -


Measuremen
t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1124


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 29 2G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

TCHH Traffic Ratio % Channel -


Configuratio
n
Measuremen
t per Cell

TCH Traffic Volume Erl KPI -


per Channel Measuremen
t per Cell

TCH Availability % Channel -


Rate per Cell Configuratio
n
Measuremen
t per Cell

TCH Resource % KPI -


Utilization Rate Measuremen
t per Cell

TCH Congestion % KPI -


Rate Measuremen
t per Cell

SDCCH Traffic Erl KPI -


Measuremen
t per Cell

SDCCH Resource % KPI -


Utilization Rate Measuremen
t per Cell

SDCCH Availability % Channel -


Rate per Cell Configuratio
n
Measuremen
t per Cell

SDCCH Congestion % KPI -


Rate Measuremen
t per Cell

RF Resource % Channel -
Utilization Rate State
Measuremen
t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1125


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 29 2G Network Capacity Analysis Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

29.3.2 Um(PS)

Um(PS)

Report Type
Simple Report

NE Type
2GBSC

Object Type
GCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Um(PS) Total RLC kB Packet -


Throughput Access
Capability
Measuremen
t

PS Resource % PDCH -
Utilization Rate Resource
Capability
Measuremen
t

PDCH Availability % Channel -


Rate per Cell Configuratio
n
Measuremen
t per Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1126


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 29 2G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Downlink PDCH None PDCH -


multiplexing Ratio Resource
Capability
Measuremen
t

BSC Reclaimed % PDCH -


Dynamic PDCH rate Resource
Capability
Measuremen
t

PDCH Congestion % PDCH -


Rate Resource
Capability
Measuremen
t

GRPS RLC kB Packet -


Throughput Access
Capability
Measuremen
t

EGRPS RLC kB Packet -


Throughput Access
Capability
Measuremen
t

Average Throughput kbit/s Uplink -


of Uplink GPRS GPRS RLC
RLC per Slot Data
Transfer
Capability
Measuremen
t

Average Throughput kbit/s Downlink -


of Downlink GPRS GPRS RLC
RLC per Slot Data
Transfer
Capability
Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1127


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 29 2G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Average Throughput kbit/s Uplink -


of Uplink EGPRS EGPRS RLC
RLC per Slot Data
Transfer
Capability
Measuremen
t

Average Throughput kbit/s Downlink -


of Downlink EGPRS EGPRS RLC
RLC per Slot Data
Transfer
Capability
Measuremen
t

Average Throughput kbit/s Uplink LLC -


of Uplink GPRS LLC Data
per User Transfer
Capability
Measuremen
t

Average Throughput kbit/s Downlink -


of Downlink GPRS LLC Data
LLC per User Transfer
Capability
Measuremen
t

Average Throughput kbit/s Uplink LLC -


of Uplink EGPRS Data
LLC per User Transfer
Capability
Measuremen
t

Average Throughput kbit/s Downlink -


of Downlink EGPRS LLC Data
LLC per User Transfer
Capability
Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1128


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 29 2G Network Capacity Analysis Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

29.4 EGPU/EXPU(CP Subsystem Detail Report)


Report Type
Simple Report

NE Type
2GBSC

Object Type
SubSys

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

EGPU/ AR9725:Average % Subsystem -


EXPU Subsys CPU Usage Measuremen
(CP of the Board t
Subsyste
m Detail
Report)

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1129


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 29 2G Network Capacity Analysis Report

29.5 EGPU/EXPU(CS UP Subsystem Detail Report)


Report Type
Simple Report

NE Type
2GBSC

Object Type
SubSys

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

EGPU/ AR9725:Average % Subsystem -


EXPU Subsys CPU Usage Measuremen
(CS UP of the Board t
Subsyste
m Detail
Report)

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

29.6 EGPU/EXPU(PS UP Subsystem Detail Report)


Report Type
Simple Report

NE Type
2GBSC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1130


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 29 2G Network Capacity Analysis Report

Object Type
SubSys

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

EGPU/ AR9725:Average % Subsystem -


EXPU Subsys CPU Usage Measuremen
(PS UP of the Board t
Subsyste
m Detail
Report)

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1131


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

30 3G Network Capacity Analysis Report

About This Chapter

30.1 Cell

30.2 NodeB

30.3 RNC

30.4 DPU DSP Utilization Rate of one Physical Subrack

30.5 DPU DSP Utilization Rate of RNC

30.6 EGPU(CP Subsystem Detail Report)

30.7 EGPU(UP Subsystem Detail Report)

30.8 EGPU CP Breakdown Report

30.9 MPU CPU Utilization Rate of RNC

30.10 Port traffic analysis

30.11 RTWP Breakdown

30.12 Breakdown Report

30.13 SPU CPU Utilization Rate of RNC

30.14 TCP Breakdown

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1132


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

30.1 Cell

30.1.1 Code

Code

Report Type
Simple Report

NE Type
3GRNC

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Code R99 Code Utilization % RRC -


Rate Connection
Setup
Measuremen
t <per Cell>

Code Utilization % Multi-RAB -


Rate Service
Measuremen
t <per Cell>

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1133


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

HSPDSCH Code

Report Type
Simple Report

NE Type
3GRNC

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

HSPDSC HSPdsch Code % HSDPA -


H Code Utilization Rate Measuremen
t <per Cell>

HSPdsch Code Used None HSDPA -


Number Measuremen
t <per Cell>

HSPdsch Code Avail None HSDPA -


Number Measuremen
t <per Cell>

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

HSSCCH Code

Report Type
Simple Report

NE Type
3GRNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1134


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

HSSCC HSSCCH Code % HSDPA -


H Code Utilization Rate Measuremen
t <per Cell>

HSSCCH Code Used None HSDPA -


Num Measuremen
t <per Cell>

HS-SCCH Code None Measuremen -


Number t related to
RNCCell
Configuratio
n

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

30.1.2 Common Channel

FACH Channel

Report Type
Simple Report

NE Type
3GRNC

Object Type
UCell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1135


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

FACH FACH Utilization % Paging -


Channel Rate Measuremen
t <per Cell>

Number of Bytes on byte Traffic -


Iub FACH Measuremen
t <per Cell>

FACH User Number None RRC Status -


Measuremen
t <per Cell>

FACH User Number % Paging -


Utilization Rate Measuremen
t <per Cell>

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

PCH Channel

Report Type
Simple Report

NE Type
3GRNC

Object Type
UCell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1136


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

PCH PCH Physical % Paging -


Channel Channel Utilization Measuremen
Rate t <per Cell>

Number of Paging None Paging -


Messages Measuremen
t <per Cell>

Number of Paging None Paging -


Messages Discarded Measuremen
Due to PCH t <per Cell>
Congestion

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

RACH Channel

Report Type
Simple Report

NE Type
3GRNC

Object Type
UCell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1137


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

RACH RACH Utilization % Traffic -


Channel Rate Measuremen
t <per Cell>

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

30.1.3 Power

RTWP

Report Type
Simple Report

NE Type
3GRNC

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

RTWP Power of Totally dBm TX and RX -


Received Bandwidth Power
(Cell) Measuremen
t <per Cell>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1138


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

TCP

Report Type
Simple Report

NE Type
3GRNC

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

TCP Total TCP % TX and RX -


Utilization Rate Power
(Cell) Measuremen
t <per Cell>

NonHS TCP % TX and RX -


Utilization Rate Power
(Cell) Measuremen
t <per Cell>

Mean Downlink kbit/s TX and RX -


Throughput of single Power
HSDPA MAC-d Measuremen
Flows t <per Cell>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1139


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

UL EUN

Report Type
Simple Report

NE Type
3GRNC

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

UL EUN UL EUN Utilization % Algorithm -


Rate Measuremen
t <per Cell>

UL total equivalent None Algorithm -


user number Measuremen
t <per Cell>

UL threshold of other % Algorithm -


services Measuremen
t <per Cell>

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1140


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

30.1.4 UCell Traffic Model Report

Report Type
Simple Report

NE Type
3GRNC

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

UCell RRC Setup Times None RRC -


Traffic Connection
Model Setup
Report Measuremen
t <per Cell>

Location Update and None RRC -


Inter-system Connection
Reselection Times Setup
Measuremen
t <per RNC>

DCH User Num numb RRC Status -


er Measuremen
t <per Cell>

FACH User Number None RRC Status -


Measuremen
t <per Cell>

PCH User Num None RRC Status -


Measuremen
t <per Cell>

HSDPA User Num None HSDPA -


Measuremen
t <per Cell>

HSUPA User Num None HSUPA -


Measuremen
t <per Cell>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1141


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

AMR Traffic Erl RB -


Procedure
Measuremen
t <per Cell>

AMR Call Times None CS RAB -


Setup
Measuremen
t <per Cell>

SHO Times Attempts None Soft -


Handover
Measuremen
t <per Cell>

Factor of soft&softer None Soft -


HO for call (CS voice Handover
call + PS call) Measuremen
t <per Cell>

PS RAB Times None PS RAB -


Setup
Measuremen
t <per Cell>

DL PS Throughput kbit/s Traffic -


Volume and
Data Rate
Measuremen
t <per Cell>

UL PS Throughput kbit/s Traffic -


Volume and
Data Rate
Measuremen
t <per Cell>

HSDPA RAB Times None PS RAB -


Setup
Measuremen
t <per RNC>

HSDPA Throughput kbit/s HSDPA -


Measuremen
t <per Cell>

HSUPA RAB Times None PS RAB -


Setup
Measuremen
t <per RNC>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1142


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

HSUPA Throughput kbit/s HSUPA -


Measuremen
t <per Cell>

Total PS Throughput None Traffic -


Volume and
Data Rate
Measuremen
t <per Cell>

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

30.1.5 UCell Traffic Trend Report

Report Type
Simple Report

NE Type
3GRNC

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

UCell AMR Call Times None CS RAB -


Traffic Setup
Trend Measuremen
Report t <per Cell>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1143


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

AMR Traffic Erl RB -


Procedure
Measuremen
t <per Cell>

PS RAB Times None PS RAB -


Setup
Measuremen
t <per Cell>

DL PS Throughput kbit/s Traffic -


Volume and
Data Rate
Measuremen
t <per Cell>

UL PS Throughput kbit/s Traffic -


Volume and
Data Rate
Measuremen
t <per Cell>

Cell Connection None RRC Status -


Number Measuremen
t <per Cell>

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

30.2 NodeB

30.2.1 CE

CE Resource

Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1144


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

NE Type
3GRNC

Object Type
RNC NodeB

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

CE DL License CE % Algorithm -
Resource Resource Utilization Measuremen
Rate t per NodeB

UL License CE % Algorithm -
Resource Utilization Measuremen
Rate t per NodeB

DL NodeB Mean CE None Algorithm -


Used Number Measuremen
t <per Cell>

UL NodeB Mean CE None Traffic -


Used Number Measuremen
t <per RNC>

DL CE Capacity % Algorithm -
Utilization Rate Measuremen
t per NodeB

UL CE Capacity % Algorithm -
Utilization Rate Measuremen
t per NodeB

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

30.2.2 CNBAP

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1145


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

CNBAP

Report Type
Simple Report

NE Type
3GRNC

Object Type
RNC NodeB

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

CNBAP CNBAP Load Ratio % IUB -


measurement
s per NodeB

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

30.2.3 HSPA User Number

HSPA User Number

Report Type
Simple Report

NE Type
3GRNC

Object Type
RNC NodeB

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1146


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

HSPA HSDPA User Used % Algorithm -


User Ratio (Mean) Measuremen
Number t per NodeB

HSUPA User Used % Algorithm -


Ratio (Mean) Measuremen
t per NodeB

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

30.2.4 Iub

Iub Signaling Plane(ATM)

Report Type
Simple Report

NE Type
3GRNC

Object Type
RNC NodeB

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Iub Iub NCP BandWidth % Algorithm -


Signaling Utilization Rate_UL Measuremen
(ATM) t per NodeB

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1147


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Plane Iub NCP kbit/s Algorithm -


(ATM) Throughput_UL Measuremen
(ATM) t per NodeB

Iub NCP kbit/s Measuremen -


BandWidth_UL t related to
(ATM) RNCNodeB
Configuratio
n

Iub NCP BandWidth % Algorithm -


Utilization Rate_DL Measuremen
(ATM) t per NodeB

Iub NCP kbit/s Algorithm -


Throughput_DL Measuremen
(ATM) t per NodeB

Iub NCP kbit/s Measuremen -


BandWidth_DL t related to
(ATM) RNCNodeB
Configuratio
n

Iub CCP BandWidth % Algorithm -


Utilization Rate_UL Measuremen
(ATM) t per NodeB

Iub CCP kbit/s Algorithm -


Throughput_UL Measuremen
(ATM) t per NodeB

Iub CCP kbit/s Measuremen -


BandWidth_UL t related to
(ATM) RNCNodeB
Configuratio
n

Iub CCP BandWidth % Algorithm -


Utilization Rate_DL Measuremen
(ATM) t per NodeB

Iub CCP kbit/s Algorithm -


Throughput_DL Measuremen
(ATM) t per NodeB

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1148


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Iub CCP kbit/s Measuremen -


BandWidth_DL t related to
(ATM) RNCNodeB
Configuratio
n

Iub ALCAP % Algorithm -


BandWidth Measuremen
Utilization Rate_UL t per NodeB
(ATM)

Iub ALCAP kbit/s Algorithm -


Throughput_UL Measuremen
(ATM) t per NodeB

Iub ALCAP kbit/s Measuremen -


BandWidth_UL t related to
(ATM) RNCNodeB
Configuratio
n

Iub ALCAP % Algorithm -


BandWidth Measuremen
Utilization Rate_DL t per NodeB
(ATM)

Iub ALCAP kbit/s Algorithm -


Throughput_DL Measuremen
(ATM) t per NodeB

Iub ALCAP kbit/s Measuremen -


BandWidth_DL t related to
(ATM) RNCNodeB
Configuratio
n

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1149


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Iub Signaling Plane(IP)

Report Type
Simple Report

NE Type
3GRNC

Object Type
RNC NodeB

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Iub Iub NCP kbit/s Algorithm -


Signaling Throughput_UL (IP) Measuremen
Plane(IP) t per NodeB

Iub NCP kbit/s Algorithm -


Throughput_DL (IP) Measuremen
t per NodeB

Iub CCP kbit/s Algorithm -


Throughput_UL (IP) Measuremen
t per NodeB

Iub CCP kbit/s Algorithm -


Throughput_DL (IP) Measuremen
t per NodeB

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Iub User Plane(ATM)

Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1150


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

NE Type
3GRNC

Object Type
RNC NodeB

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Iub User Iub User Plane % Algorithm -


Plane BandWidth Measuremen
(ATM) Utilization Rate_UL t per NodeB
(ATM)

Iub User Plane kbit/s Algorithm -


Throughput_UL Measuremen
(ATM) t per NodeB

Iub User Plane Peak kbit/s Algorithm -


Throughput_UL Measuremen
(ATM) t per NodeB

Iub User Plane kbit/s Measuremen -


BandWidth_UL t related to
(ATM) RNCNodeB
Configuratio
n

Iub User Plane % Algorithm -


BandWidth Measuremen
Utilization Rate_DL t per NodeB
(ATM)

Iub User Plane kbit/s Algorithm -


Throughput_DL Measuremen
(ATM) t per NodeB

Iub User Plane Peak kbit/s Algorithm -


Throughput_DL Measuremen
(ATM) t per NodeB

Iub User Plane kbit/s Measuremen -


BandWidth_DL t related to
(ATM) RNCNodeB
Configuratio
n

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1151


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Iub User Plane % Algorithm -


Allocated Measuremen
BandWidth t per NodeB
Utilization Rate_UL
(ATM)

Iub User Plane kbit/s Algorithm -


Allocated Measuremen
BandWidth_UL t per NodeB
(ATM)

Iub User Plane % Algorithm -


Allocated Measuremen
BandWidth t per NodeB
Utilization Rate_DL
(ATM)

Iub User Plane kbit/s Algorithm -


Allocated Measuremen
BandWidth_DL t per NodeB
(ATM)

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Iub User Plane(IP)

Report Type
Simple Report

NE Type
3GRNC

Object Type
RNC NodeB

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1152


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Iub User Iub User Plane % Algorithm -


Plane(IP) BandWidth Measuremen
Utilization Rate_UL t per NodeB
(IP)

Iub User Plane kbit/s Algorithm -


Throughput_UL (IP) Measuremen
t per NodeB

Iub User Plane Peak kbit/s Algorithm -


Throughput_UL (IP) Measuremen
t per NodeB

Iub User Plane kbit/s Measuremen -


BandWidth_UL(IP) t related to
RNCNodeB
Configuratio
n

Iub User Plane % Algorithm -


BandWidth Measuremen
Utilization Rate_DL t per NodeB
(IP)

Iub User Plane kbit/s Algorithm -


Throughput_DL (IP) Measuremen
t per NodeB

Iub User Plane Peak kbit/s Algorithm -


Throughput_DL (IP) Measuremen
t per NodeB

Iub User Plane kbit/s Measuremen -


BandWidth_DL(IP) t related to
RNCNodeB
Configuratio
n

Iub User Plane % Algorithm -


Allocated Measuremen
BandWidth t per NodeB
Utilization Rate_UL
(IP)

Iub User Plane kbit/s Algorithm -


Allocated Measuremen
BandWidth_UL (IP) t per NodeB

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1153


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Iub User Plane % Algorithm -


Allocated Measuremen
BandWidth t per NodeB
Utilization Rate_DL
(IP)

Iub User Plane kbit/s Algorithm -


Allocated Measuremen
BandWidth_DL (IP) t per NodeB

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Iub User Plane(IP POOL)

Report Type
Simple Report

NE Type
3GRNC

Object Type
RNC NodeB

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1154


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Iub User Iub User Plane kbit/s Transmission -


Plane(IP Throughput_UL (IP Resource
POOL) POOL) Pool
Adjacent
Node User-
Plane Traffic
Measuremen
t

Iub User Plane % Transmission -


BandWidth Resource
Utilization Rate_UL Pool
(IP POOL) Adjacent
Node User-
Plane Traffic
Measuremen
t

Iub User Plane kbit/s Transmission -


Throughput_DL (IP Resource
POOL) Pool
Adjacent
Node User-
Plane Traffic
Measuremen
t

Iub User Plane % Transmission -


BandWidth Resource
Utilization Rate_DL Pool
(IP POOL) Adjacent
Node User-
Plane Traffic
Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1155


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

30.2.5 NodeB Board

NodeB Board

Report Type
Simple Report

NE Type
3GBTS

Object Type
NodeB Board

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Board NodeB Board CPU % Board Load -


Utilization Rate Measuremen
(Mean) t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

30.2.6 NodeB License

NodeB License

Report Type
Simple Report

NE Type
3GRNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1156


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Object Type
RNC NodeB

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

NodeB NodeB HS-PDSCH % HSDPA -


License Code License Measuremen
Utilization Rate ts per Local
Cell

NodeB CNBAP % NodeB -


License Utilization NBAP
Rate procedure
measurement

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

30.2.7 NodeB Traffic Model Report

Report Type
Simple Report

NE Type
3GRNC

Object Type
RNC NodeB

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1157


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

NodeB RRC Setup Times None RRC -


Traffic Connection
Model Setup
Report Measuremen
t <per Cell>

Location Update and None RRC -


Inter-system Connection
Reselection Times Setup
Measuremen
t <per RNC>

DCH User Num numb RRC Status -


er Measuremen
t <per Cell>

FACH User Number None RRC Status -


Measuremen
t <per Cell>

PCH User Num None RRC Status -


Measuremen
t <per Cell>

HSDPA User Num None HSDPA -


Measuremen
t <per Cell>

HSUPA User Num None HSUPA -


Measuremen
t <per Cell>

AMR Traffic Erl RB -


Procedure
Measuremen
t <per Cell>

AMR Call Times None CS RAB -


Setup
Measuremen
t <per Cell>

SHO Times Attempts None Soft -


Handover
Measuremen
t <per Cell>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1158


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Factor of soft&softer None Soft -


HO for call (CS voice Handover
call + PS call) Measuremen
t <per Cell>

PS RAB Times None PS RAB -


Setup
Measuremen
t <per Cell>

DL PS Throughput kbit/s Traffic -


Volume and
Data Rate
Measuremen
t <per Cell>

UL PS Throughput kbit/s Traffic -


Volume and
Data Rate
Measuremen
t <per Cell>

HSDPA RAB Times None PS RAB -


Setup
Measuremen
t <per RNC>

HSDPA Throughput kbit/s HSDPA -


Measuremen
t <per Cell>

HSUPA RAB Times None PS RAB -


Setup
Measuremen
t <per RNC>

HSUPA Throughput kbit/s HSUPA -


Measuremen
t <per Cell>

Total PS Throughput None Traffic -


Volume and
Data Rate
Measuremen
t <per Cell>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1159


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

30.2.8 NodeB Traffic Trend Report

Report Type
Simple Report

NE Type
3GRNC

Object Type
RNC NodeB

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

NodeB AMR Call Times None CS RAB -


Traffic Setup
Trend Measuremen
Report t <per Cell>

AMR Traffic Erl RB -


Procedure
Measuremen
t <per Cell>

PS RAB Times None PS RAB -


Setup
Measuremen
t <per Cell>

DL PS Throughput kbit/s Traffic -


Volume and
Data Rate
Measuremen
t <per Cell>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1160


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

UL PS Throughput kbit/s Traffic -


Volume and
Data Rate
Measuremen
t <per Cell>

NodeB CNBAP None NodeB -


consumption NBAP
procedure
measurement

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

30.3 RNC

30.3.1 Board

DPU(BSC6900UMTS)

Report Type
Simple Report

NE Type
3GRNC

Object Type
3G DSP

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1161


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

DPU DPU Board DSP % DSP -


Utilization Rate Measuremen
(Mean) t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

EGPU(CP)(BSC6910UMTS)

Report Type
Simple Report

NE Type
3GRNC

Object Type
SubSys Virtual Group

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

EGPU EGPU Board CP % Subsystem -


(CP) CPU Utilization Rate Measuremen
(Mean)_UMTS t

EGPU Board CP None Measuremen -


Subsystem t related to
Number_UMTS EGPU
Subsystem
Configuratio
n

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1162


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

EGPU(UP)(BSC6910UMTS)

Report Type
Simple Report

NE Type
3GRNC

Object Type
SubSys Virtual Group

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

EGPU EGPU Board UP % Subsystem -


(UP) CPU Utilization Rate Measuremen
(Mean)_UMTS t

EGPU Board UP None Measuremen -


Subsystem t related to
Number_UMTS EGPU
Subsystem
Configuratio
n

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1163


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

INT(BSC6900UMTS)

Report Type
Simple Report

NE Type
3GRNC

Object Type
Board

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

INT INT Board CPU % Interface -


Utilization Rate Board
(Mean)_UMTS Subsystem
Measuremen
t

INT Board User % Interface -


Plane Utilization Board
Rate (Mean)_UMTS Subsystem
Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1164


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

INT(Signaling Plane)(BSC6910UMTS)

Report Type
Simple Report

NE Type
3GRNC

Object Type
CPU

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

INT INT Board Signaling % CPU -


(Signalin Plane Utilization Measuremen
g Plane) Rate (Mean)_UMTS t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

INT(User Plane)(BSC6910UMTS)

Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1165


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

NE Type
3GRNC

Object Type
Board

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

INT INT Board User % Interface -


(User Plane Utilization Board
Plane) Rate (Mean)_UMTS Subsystem
Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

MPU(BSC6900UMTS)

Report Type
Simple Report

NE Type
3GRNC

Object Type
Board

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1166


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

MPU MPU Board CPU % XPU -


Utilization Rate Subsystem
(Mean) Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

RMP(BSC6910UMTS)

Report Type
Simple Report

NE Type
3GRNC

Object Type
CPU

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

RMP RMP Board CPU % CPU -


Utilization Rate Measuremen
(Mean)_UMTS t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1167


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

SCU(BSC6900UMTS)

Report Type
Simple Report

NE Type
3GRNC

Object Type
Board

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

SCU SCU Board CPU % SCU -


Utilization Rate Subsystem
(Mean) Measuremen
_BSC6900_UMTS t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

SCU(BSC6910UMTS)

Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1168


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

NE Type
3GRNC

Object Type
CPU

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

SCU SCU Board CPU % CPU -


Utilization Rate Measuremen
(Mean) t
_BSC6910_UMTS

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

SCU Tx Ability(BSC6900UMTS)

Report Type
Simple Report

NE Type
3GRNC

Object Type
Inter-Subrack Traffic Object

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1169


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

SCU Tx SCU Send Traffic % Inter- -


Ability Utilization Rate Subrack
(Mean)_UMTS Traffic
Measuremen
t

SCU Send Traffic kbit/s Inter- -


(Mean)_UMTS Subrack
Traffic
Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

SCU Tx Ability(BSC6910UMTS)

Report Type
Simple Report

NE Type
3GRNC

Object Type
Inter-Subrack Traffic Object

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1170


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

SCU Tx SCU Send Traffic % Inter- -


Ability Utilization Rate Subrack
(Mean)_UMTS Traffic
Measuremen
t

SCU Send Traffic kbit/s Inter- -


(Mean)_UMTS Subrack
Traffic
Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

SPU(BSC6900UMTS)

Report Type
Simple Report

NE Type
3GRNC

Object Type
Board

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1171


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

SPU SPU Board CPU % XPU -


Utilization Rate Subsystem
(Mean) Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

30.3.2 Iu-CS

IuCS Signaling Plane(ATM)

Report Type
Simple Report

NE Type
3GRNC

Object Type
MTP3B DSP

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

IuCS IuCS Signaling Plane % MTP3 DSP -


Signaling Utilization Rate_DL Measuremen
Plane (ATM) t
(ATM)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1172


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

IuCS Signaling Plane kbit/s MTP3 DSP -


Throughput_DL Measuremen
(ATM) t

IuCS Signaling Plane kbit/s Measuremen -


BandWidth_DL t related to
(ATM) N7DPC
Configuratio
n

IuCS Signaling Plane % MTP3 DSP -


Utilization Rate_UL Measuremen
(ATM) t

IuCS Signaling Plane kbit/s MTP3 DSP -


Throughput_UL Measuremen
(ATM) t

IuCS Signaling Plane kbit/s Measuremen -


BandWidth_UL t related to
(ATM) N7DPC
Configuratio
n

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

IuCS Signaling Plane(IP)

Report Type
Simple Report

NE Type
3GRNC

Object Type
MTP3B DSP

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1173


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

IuCS IuCS Signaling Plane kbit/s MTP3 DSP -


Signaling Throughput_DL (IP) Measuremen
Plane(IP) t

IuCS Signaling Plane kbit/s MTP3 DSP -


Throughput_UL (IP) Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

IuCS User Plane(ATM)

Report Type
Simple Report

NE Type
3GRNC

Object Type
QAAL2 Node

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

IuCS IuCS User Plane % QAAL2 -


User Utilization Rate_DL Measuremen
Plane (ATM) t
(ATM)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1174


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

IuCS User Plane kbit/s QAAL2 -


Throughput_DL Measuremen
(ATM) t

IuCS User Plane kbit/s Measuremen -


BandWidth_DL t related to
(ATM) ADJNODE
Configuratio
n

IuCS User Plane % QAAL2 -


Utilization Rate_UL Measuremen
(ATM) t

IuCS User Plane kbit/s QAAL2 -


Throughput_UL Measuremen
(ATM) t

IuCS User Plane kbit/s Measuremen -


BandWidth_UL t related to
(ATM) ADJNODE
Configuratio
n

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

IuCS User Plane(IP)

Report Type
Simple Report

NE Type
3GRNC

Object Type
QAAL2 Node

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1175


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

IuCS IuCS User Plane % QAAL2 -


User Utilization Rate_DL Measuremen
Plane(IP) (IP) t

IuCS User Plane kbit/s QAAL2 -


Throughput_DL (IP) Measuremen
t

IuCS User Plane kbit/s Measuremen -


BandWidth_DL(IP) t related to
ADJNODE
Configuratio
n

IuCS User Plane % QAAL2 -


Utilization Rate_UL Measuremen
(IP) t

IuCS User Plane kbit/s QAAL2 -


Throughput_UL (IP) Measuremen
t

IuCS User Plane kbit/s Measuremen -


BandWidth_UL(IP) t related to
ADJNODE
Configuratio
n

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

IuCS User Plane(IP POOL)

Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1176


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

NE Type
3GRNC

Object Type
QAAL2 Node

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

IuCS IuCS User Plane % Transmission -


User BandWidth Resource
Plane(IP Utilization Rate_DL Pool
POOL) (IP POOL) Adjacent
Node User-
Plane Traffic
Measuremen
t

IuCS User Plane kbit/s Transmission -


Throughput_DL (IP Resource
POOL) Pool
Adjacent
Node User-
Plane Traffic
Measuremen
t

IuCS User Plane kbit/s Transmission -


BandWidth_DL (IP Resource
POOL) Pool
Adjacent
Node User-
Plane Traffic
Measuremen
t

IuCS User Plane % Transmission -


BandWidth Resource
Utilization Rate_UL Pool
(IP POOL) Adjacent
Node User-
Plane Traffic
Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1177


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

IuCS User Plane kbit/s Transmission -


Throughput_UL (IP Resource
POOL) Pool
Adjacent
Node User-
Plane Traffic
Measuremen
t

IuCS User Plane kbit/s Transmission -


BandWidth_UL (IP Resource
POOL) Pool
Adjacent
Node User-
Plane Traffic
Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

30.3.3 Iu-PS

IuPS Signaling Plane(ATM)

Report Type
Simple Report

NE Type
3GRNC

Object Type
MTP3B DSP

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1178


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

IuPS IuPS Signaling Plane % MTP3 DSP -


Signaling Utilization Rate_UL Measuremen
Plane (ATM) t
(ATM)
IuPS Signaling Plane kbit/s MTP3 DSP -
Throughput_UL Measuremen
(ATM) t

IuPS Signaling Plane kbit/s Measuremen -


BandWidth_UL t related to
(ATM) N7DPC
Configuratio
n

IuPS Signaling Plane % MTP3 DSP -


Utilization Rate_DL Measuremen
(ATM) t

IuPS Signaling Plane kbit/s MTP3 DSP -


Throughput_DL Measuremen
(ATM) t

IuPS Signaling Plane kbit/s Measuremen -


BandWidth_DL t related to
(ATM) N7DPC
Configuratio
n

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

IuPS Signaling Plane(IP)

Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1179


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

NE Type
3GRNC

Object Type
MTP3B DSP

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

IuPS IuPS Signaling Plane kbit/s MTP3 DSP -


Signaling Throughput_DL (IP) Measuremen
Plane(IP) t

IuPS Signaling Plane kbit/s MTP3 DSP -


Throughput_UL (IP) Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

IuPS User Plane(ATM)

Report Type
Simple Report

NE Type
3GRNC

Object Type
QAAL2 Node

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1180


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

IuPS IuPS User Plane % QAAL2 -


User Utilization Rate_DL Measuremen
Plane (ATM) t
(ATM)
IuPS User Plane kbit/s QAAL2 -
Throughput_DL Measuremen
(ATM) t

IuPS User Plane kbit/s QAAL2 -


BandWidth_UL Measuremen
(ATM) t

IuPS User Plane % QAAL2 -


Utilization Rate_UL Measuremen
(ATM) t

IuPS User Plane kbit/s QAAL2 -


Throughput_UL Measuremen
(ATM) t

IuPS User Plane kbit/s QAAL2 -


BandWidth_DL Measuremen
(ATM) t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

IuPS User Plane(IP)

Report Type
Simple Report

NE Type
3GRNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1181


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Object Type
QAAL2 Node

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

IuPS IuPS User Plane % QAAL2 -


User Utilization Rate_DL Measuremen
Plane(IP) (IP) t

IuPS User Plane kbit/s QAAL2 -


Throughput_DL (IP) Measuremen
t

IuPS User Plane kbit/s Measuremen -


BandWidth_DL(IP) t related to
ADJNODE
Configuratio
n

IuPS User Plane % QAAL2 -


Utilization Rate_UL Measuremen
(IP) t

IuPS User Plane kbit/s QAAL2 -


Throughput_UL (IP) Measuremen
t

IuPS User Plane kbit/s Measuremen -


BandWidth_UL(IP) t related to
ADJNODE
Configuratio
n

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1182


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

IuPS User Plane(IP POOL)

Report Type
Simple Report

NE Type
3GRNC

Object Type
QAAL2 Node

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

IuPS IuPS User Plane % Transmission -


User BandWidth Resource
Plane(IP Utilization Rate_DL Pool
POOL) (IP POOL) Adjacent
Node User-
Plane Traffic
Measuremen
t

IuPS User Plane kbit/s Transmission -


Throughput_DL (IP Resource
POOL) Pool
Adjacent
Node User-
Plane Traffic
Measuremen
t

IuPS User Plane kbit/s Transmission -


BandWidth_DL (IP Resource
POOL) Pool
Adjacent
Node User-
Plane Traffic
Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1183


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

IuPS User Plane % Transmission -


BandWidth Resource
Utilization Rate_UL Pool
(IP POOL) Adjacent
Node User-
Plane Traffic
Measuremen
t

IuPS User Plane kbit/s Transmission -


Throughput_UL (IP Resource
POOL) Pool
Adjacent
Node User-
Plane Traffic
Measuremen
t

IuPS User Plane kbit/s Transmission -


BandWidth_UL (IP Resource
POOL) Pool
Adjacent
Node User-
Plane Traffic
Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

30.3.4 Iur

Iur Signaling Plane(ATM)

Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1184


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

NE Type
3GRNC

Object Type
MTP3B DSP

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Iur Iur Signaling Plane % MTP3 DSP -


Signaling Utilization Rate_RX Measuremen
Plane (ATM) t
(ATM)
Iur Signaling Plane kbit/s MTP3 DSP -
Throughput_RX Measuremen
(ATM) t

Iur Signaling Plane kbit/s Measuremen -


BandWidth_RX t related to
(ATM) N7DPC
Configuratio
n

Iur Signaling Plane % MTP3 DSP -


Utilization Rate_TX Measuremen
(ATM) t

Iur Signaling Plane kbit/s MTP3 DSP -


Throughput_TX Measuremen
(ATM) t

Iur Signaling Plane kbit/s Measuremen -


BandWidth_TX t related to
(ATM) N7DPC
Configuratio
n

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1185


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Iur Signaling Plane(IP)

Report Type
Simple Report

NE Type
3GRNC

Object Type
MTP3B DSP

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Iur Iur Signaling Plane kbit/s MTP3 DSP -


Signaling Throughput_RX (IP) Measuremen
Plane(IP) t

Iur Signaling Plane kbit/s MTP3 DSP -


Throughput_TX (IP) Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Iur User Plane(ATM)

Report Type
Simple Report

NE Type
3GRNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1186


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Object Type
QAAL2 Node

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Iur User Iur User Plane % QAAL2 -


Plane Utilization Rate_RX Measuremen
(ATM) (ATM) t

Iur User Plane kbit/s QAAL2 -


Throughput_RX Measuremen
(ATM) t

Iur User Plane kbit/s Measuremen -


BandWidth_RX t related to
(ATM) ADJNODE
Configuratio
n

Iur User Plane % QAAL2 -


Utilization Rate_TX Measuremen
(ATM) t

Iur User Plane kbit/s QAAL2 -


Throughput_TX Measuremen
(ATM) t

Iur User Plane kbit/s Measuremen -


BandWidth_TX t related to
(ATM) ADJNODE
Configuratio
n

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1187


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Iur User Plane(IP)

Report Type
Simple Report

NE Type
3GRNC

Object Type
QAAL2 Node

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Iur User Iur User Plane % QAAL2 -


Plane(IP) Utilization Rate_RX Measuremen
(IP) t

Iur User Plane kbit/s QAAL2 -


Throughput_RX (IP) Measuremen
t

Iur User Plane kbit/s Measuremen -


BandWidth_RX(IP) t related to
ADJNODE
Configuratio
n

Iur User Plane % QAAL2 -


Utilization Rate_TX Measuremen
(IP) t

Iur User Plane kbit/s QAAL2 -


Throughput_TX (IP) Measuremen
t

Iur User Plane kbit/s Measuremen -


BandWidth_TX(IP) t related to
ADJNODE
Configuratio
n

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1188


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Iur User Plane(IP POOL)

Report Type
Simple Report

NE Type
3GRNC

Object Type
QAAL2 Node

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Iur User Iur User Plane % Transmission -


Plane(IP BandWidth Resource
POOL) Utilization Rate_RX Pool
(IP POOL) Adjacent
Node User-
Plane Traffic
Measuremen
t

Iur User Plane kbit/s Transmission -


Throughput_RX (IP Resource
POOL) Pool
Adjacent
Node User-
Plane Traffic
Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1189


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Iur User Plane kbit/s Transmission -


BandWidth_RX (IP Resource
POOL) Pool
Adjacent
Node User-
Plane Traffic
Measuremen
t

Iur User Plane % Transmission -


BandWidth Resource
Utilization Rate_TX Pool
(IP POOL) Adjacent
Node User-
Plane Traffic
Measuremen
t

Iur User Plane kbit/s Transmission -


Throughput_TX (IP Resource
POOL) Pool
Adjacent
Node User-
Plane Traffic
Measuremen
t

Iur User Plane kbit/s Transmission -


BandWidth_TX (IP Resource
POOL) Pool
Adjacent
Node User-
Plane Traffic
Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1190


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

30.3.5 License

RNC License_Active User(BSC6910UMTS)

Report Type
Simple Report

NE Type
3GRNC

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

RNC RNC Active User % RRC Status -


License_ Hardware Capacity Measuremen
Active License Utilization t <per RNC>
User Rate

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

RNC License_Active User(BSC6900UMTS)

Report Type
Simple Report

NE Type
3GRNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1191


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

RNC PS Active User % Traffic -


License_ License Utilization Measuremen
Active Rate t per PLMN
User

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

RNC License_Hardware Capacity(BSC6910UMTS)

Report Type
Simple Report

NE Type
3GRNC

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

RNC RNC Hardware % Traffic -


License_ Capacity License Measuremen
Hardwar Utilization t <per RNC>
Rate_BSC6910

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1192


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

e RNC ENIUa License % Traffic -


Capacity Utilization Rate Measuremen
t <per RNC>

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

RNC License_Hardware Capacity(BSC6900UMTS)

Report Type
Simple Report

NE Type
3GRNC

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

RNC RNC Hardware % Traffic -


License_ Capacity License Measuremen
Hardwar Utilization t <per RNC>
e Rate_BSC6900
Capacity
RNC NIUa License % Traffic -
Utilization Rate Measuremen
t <per RNC>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1193


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

RNC License_HSPA User Number(BSC6910UMTS)

Report Type
Simple Report

NE Type
3GRNC

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

RNC Cell HSDPA Users % HSDPA -


License_ License Utilization Measuremen
HSPA Rate t <per Cell>
User
Number Cell HSUPA Users % HSUPA -
License Utilization Measuremen
Rate t <per Cell>

32 HSDPA Users per % Traffic -


Cell License Measuremen
Allocated t <per RNC>
Throughput
Utilization Rate

64 HSDPA Users per % Traffic -


Cell License Measuremen
Allocated t <per RNC>
Throughput
Utilization Rate

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1194


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

96 HSDPA Users per % Traffic -


Cell License Measuremen
Allocated t <per RNC>
Throughput
Utilization Rate

128 HSDPA Users % Traffic -


per Cell License Measuremen
Allocated t <per RNC>
Throughput
Utilization Rate

60 HSUPA Users per % Traffic -


Cell License Measuremen
Allocated t <per RNC>
Throughput
Utilization Rate

96 HSUPA Users per % Traffic -


Cell License Measuremen
Allocated t <per RNC>
Throughput
Utilization Rate

128 HSUPA Users % Traffic -


per Cell License Measuremen
Allocated t <per RNC>
Throughput
Utilization Rate

160 HSPA Users per % Traffic -


Cell License Measuremen
Allocated t <per RNC>
Throughput
Utilization Rate

192 HSPA Users per % Traffic -


Cell License Measuremen
Allocated t <per RNC>
Throughput
Utilization Rate

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1195


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

RNC License_HSPA User Number(BSC6900UMTS)

Report Type
Simple Report

NE Type
3GRNC

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

RNC Cell HSDPA Users % HSDPA -


License_ License Utilization Measuremen
HSPA Rate t <per Cell>
User
Number Cell HSUPA Users % HSUPA -
License Utilization Measuremen
Rate t <per Cell>

32 HSDPA Users per % Traffic -


Cell License Measuremen
Allocated t <per RNC>
Throughput
Utilization Rate

64 HSDPA Users per % Traffic -


Cell License Measuremen
Allocated t <per RNC>
Throughput
Utilization Rate

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1196


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

96 HSDPA Users per % Traffic -


Cell License Measuremen
Allocated t <per RNC>
Throughput
Utilization Rate

128 HSDPA Users % Traffic -


per Cell License Measuremen
Allocated t <per RNC>
Throughput
Utilization Rate

60 HSUPA Users per % Traffic -


Cell License Measuremen
Allocated t <per RNC>
Throughput
Utilization Rate

96 HSUPA Users per % Traffic -


Cell License Measuremen
Allocated t <per RNC>
Throughput
Utilization Rate

128 HSUPA Users % Traffic -


per Cell License Measuremen
Allocated t <per RNC>
Throughput
Utilization Rate

160 HSPA Users per % Traffic -


Cell License Measuremen
Allocated t <per RNC>
Throughput
Utilization Rate

192 HSPA Users per % Traffic -


Cell License Measuremen
Allocated t <per RNC>
Throughput
Utilization Rate

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1197


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

RNC License_Traffic(BSC6910UMTS)

Report Type
Simple Report

NE Type
3GRNC

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

RNC CS License Ratio % Traffic -


License_ Measuremen
Traffic t <per RNC>

PS R99 Throughput % Traffic -


Ratio Measuremen
t <per RNC>

HSDPA Throughput % Traffic -


Ratio Measuremen
t <per RNC>

HSUPA Throughput % Traffic -


Ratio Measuremen
t <per RNC>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1198


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

RNC License_Traffic(BSC6900UMTS)

Report Type
Simple Report

NE Type
3GRNC

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

RNC CS License Ratio % Traffic -


License_ Measuremen
Traffic t <per RNC>

PS R99 Throughput % Traffic -


Ratio Measuremen
t <per RNC>

HSDPA Throughput % Traffic -


Ratio Measuremen
t <per RNC>

HSUPA Throughput % Traffic -


Ratio Measuremen
t <per RNC>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1199


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

RNC License_Traffic(RAN Sharing or MOCN)(BSC6910UMTS)

Report Type
Simple Report

NE Type
3GRNC

Object Type
CNOPERATOR

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

RNC CS License Ratio % Traffic -


License_ (RAN Sharing or Measuremen
Traffic MOCN) t per PLMN
(RAN
Sharing PS R99 Throughput % Traffic -
or Ratio (RAN Sharing Measuremen
MOCN) or MOCN) t per PLMN

HSDPA Throughput % Traffic -


Ratio (RAN Sharing Measuremen
or MOCN) t per PLMN

HSUPA Throughput % Traffic -


Ratio (RAN Sharing Measuremen
or MOCN) t per PLMN

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1200


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

RNC License_Traffic(RAN Sharing or MOCN)(BSC6900UMTS)

Report Type
Simple Report

NE Type
3GRNC

Object Type
CNOPERATOR

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

RNC CS License Ratio % Traffic -


License_ (RAN Sharing or Measuremen
Traffic MOCN) t per PLMN
(RAN
Sharing PS R99 Throughput % Traffic -
or Ratio (RAN Sharing Measuremen
MOCN) or MOCN) t per PLMN

HSDPA Throughput % Traffic -


Ratio (RAN Sharing Measuremen
or MOCN) t per PLMN

HSUPA Throughput % Traffic -


Ratio (RAN Sharing Measuremen
or MOCN) t per PLMN

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1201


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

30.3.6 RNC Traffic Model Report(6910UMTS)

Report Type
Simple Report

NE Type
3GRNC

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

RNC User Number None Traffic -


Traffic Measuremen
Model t <per RNC>
Report
AMR Traffic per Erl Traffic -
User Measuremen
t <per RNC>

AMR Call Times per None CS RAB -


User Setup
Measuremen
t <per RNC>

VP Traffic per User Erl RB -


Procedure
Measuremen
t <per RNC>

VP Call Times per None RB -


User Procedure
Measuremen
t <per RNC>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1202


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Location Update and None RB -


Inter-system Procedure
Reselection Times Measuremen
per User t <per RNC>

SHO Times Attempts None Soft -


per User Handover
Measuremen
t <per RNC>

Factor of None Soft -


Soft&Softer HO for Handover
Call (CS Voice Call + Measuremen
PS Call) t <per RNC>

PS RAB Times per None PS RAB -


User Setup
Measuremen
t <per RNC>

Total PS Throughput kbit/s Traffic -


per User Measuremen
t <per RNC>

DL PS Throughput kbit/s Traffic -


per User Measuremen
t <per RNC>

DL R99 PS kbit/s Traffic -


Throughput per User Measuremen
t <per RNC>

UL PS Throughput kbit/s Traffic -


per User Measuremen
t <per RNC>

UL R99 PS kbit/s Traffic -


Throughput per User Measuremen
t <per RNC>

Ratio of DL PS None Traffic -


Throughput vs UL Measuremen
PS Throughput t <per RNC>

Cell Update Times None RRC -


per User Connection
Setup
Measuremen
t <per RNC>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1203


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

PS Channel Switch None RB -


Times per User Procedure
Measuremen
t <per RNC>

PS RAB Number None PS RAB -


Mean Setup
Measuremen
t <per RNC>

HSDPA RAB Times None RRC -


per User Connection
Setup
Measuremen
t <per RNC>

Ratio of HSDPA % PS RAB -


Traffic vs DL PS Setup
Measuremen
t <per RNC>

HSUPA RAB Times None RRC -


per User Connection
Setup
Measuremen
t <per RNC>

Ratio of HSUPA % PS RAB -


Traffic vs UL PS Setup
Measuremen
t <per RNC>

Number of UEs in None RRC Status -


CELL_DCH State Measuremen
t <per RNC>

Number of UEs in None RRC Status -


CELL_FACH State Measuremen
t <per RNC>

Number of UEs in None RRC Status -


CELL_PCH State Measuremen
t <per RNC>

Number of UEs in None RRC Status -


URA_PCH State Measuremen
t <per RNC>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1204


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

EGPU Board CP kbit/s Subsystem -


CPU Utilization Rate Measuremen
(Mean) Sum_UMTS t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

30.3.7 RNC Traffic Model Report(6900UMTS)

Report Type
Simple Report

NE Type
3GRNC

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

RNC User Number None Traffic -


Traffic Measuremen
Model t <per RNC>
Report
AMR Traffic per Erl Traffic -
User Measuremen
t <per RNC>

AMR Call Times per None CS RAB -


User Setup
Measuremen
t <per RNC>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1205


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

VP Traffic per User Erl RB -


Procedure
Measuremen
t <per RNC>

VP Call Times per None RB -


User Procedure
Measuremen
t <per RNC>

Location Update and None RB -


Inter-system Procedure
Reselection Times Measuremen
per User t <per RNC>

SHO Times Attempts None Soft -


per User Handover
Measuremen
t <per RNC>

Factor of None Soft -


Soft&Softer HO for Handover
Call (CS Voice Call + Measuremen
PS Call) t <per RNC>

PS RAB Times per None PS RAB -


User Setup
Measuremen
t <per RNC>

Total PS Throughput kbit/s Traffic -


per User Measuremen
t <per RNC>

DL PS Throughput kbit/s Traffic -


per User Measuremen
t <per RNC>

DL R99 PS kbit/s Traffic -


Throughput per User Measuremen
t <per RNC>

UL PS Throughput kbit/s Traffic -


per User Measuremen
t <per RNC>

UL R99 PS kbit/s Traffic -


Throughput per User Measuremen
t <per RNC>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1206


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Ratio of DL PS None Traffic -


Throughput vs UL Measuremen
PS Throughput t <per RNC>

Cell Update Times None RRC -


per User Connection
Setup
Measuremen
t <per RNC>

PS Channel Switch None RB -


Times per User Procedure
Measuremen
t <per RNC>

PS RAB Number None PS RAB -


Mean Setup
Measuremen
t <per RNC>

HSDPA RAB Times None RRC -


per User Connection
Setup
Measuremen
t <per RNC>

Ratio of HSDPA % PS RAB -


Traffic vs DL PS Setup
Measuremen
t <per RNC>

HSUPA RAB Times None RRC -


per User Connection
Setup
Measuremen
t <per RNC>

Ratio of HSUPA % PS RAB -


Traffic vs UL PS Setup
Measuremen
t <per RNC>

Number of UEs in None RRC Status -


CELL_DCH State Measuremen
t <per RNC>

Number of UEs in None RRC Status -


CELL_FACH State Measuremen
t <per RNC>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1207


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Number of UEs in None RRC Status -


CELL_PCH State Measuremen
t <per RNC>

Number of UEs in None RRC Status -


URA_PCH State Measuremen
t <per RNC>

VS.XPU.CPULOA % XPU -
D.MEAN Subsystem
Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

30.3.8 RNC Traffic Trend Report(6910UMTS)

Report Type
Simple Report

NE Type
3GRNC

Object Type
RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1208


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

RNC AMR Call Times None CS RAB -


Traffic Setup
Trend Measuremen
Report t <per RNC>

AMR Traffic Erl Traffic -


Measuremen
t <per RNC>

PS RAB Times None PS RAB -


Setup
Measuremen
t <per RNC>

DL PS Throughput kbit/s Traffic -


Measuremen
t <per RNC>

UL PS Throughput kbit/s Traffic -


Measuremen
t <per RNC>

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

30.3.9 RNC Traffic Trend Report(6900UMTS)

Report Type
Simple Report

NE Type
3GRNC

Object Type
RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1209


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

RNC AMR Call Times None CS RAB -


Traffic Setup
Trend Measuremen
Report t <per RNC>

AMR Traffic Erl Traffic -


Measuremen
t <per RNC>

PS RAB Times None PS RAB -


Setup
Measuremen
t <per RNC>

DL PS Throughput kbit/s Traffic -


Measuremen
t <per RNC>

UL PS Throughput kbit/s Traffic -


Measuremen
t <per RNC>

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

30.3.10 UCell Group Traffic Trend Report

Report Type
Simple Report

NE Type
3GRNC

Object Type
UCell Group

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1210


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

UCell AMR Call Times None CS RAB -


Group Setup
Traffic Measuremen
Trend t <per Cell>
Report
AMR Traffic Erl RB -
Procedure
Measuremen
t <per Cell>

PS RAB Times None PS RAB -


Setup
Measuremen
t <per Cell>

DL PS Throughput kbit/s Traffic -


Volume and
Data Rate
Measuremen
t <per Cell>

UL PS Throughput kbit/s Traffic -


Volume and
Data Rate
Measuremen
t <per Cell>

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

30.4 DPU DSP Utilization Rate of one Physical Subrack


Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1211


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

NE Type
3GRNC

Object Type
Frame

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

DPU Average DPU DSP % Measuremen -


DSP Utilization Rate t related to
Utilizatio under one Physical RNC Frame
n Rate of Subrack Configuratio
one n
Physical
Subrack

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

30.5 DPU DSP Utilization Rate of RNC


Report Type
Simple Report

NE Type
3GRNC

Object Type
RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1212


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

DPU Average DPU DSP % Traffic -


DSP Utilization Rate of Measuremen
Utilizatio RNC t <per RNC>
n Rate of
RNC

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

30.6 EGPU(CP Subsystem Detail Report)


Report Type
Simple Report

NE Type
3GRNC

Object Type
SubSys

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

EGPU AR9725:Average % Subsystem -


(CP Subsys CPU Usage Measuremen
Subsyste of the Board t
m Detail
Report)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1213


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

30.7 EGPU(UP Subsystem Detail Report)


Report Type
Simple Report

NE Type
3GRNC

Object Type
SubSys

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

EGPU AR9725:Average % Subsystem -


(UP Subsys CPU Usage Measuremen
Subsyste of the Board t
m Detail
Report)

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1214


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

30.8 EGPU CP Breakdown Report


Report Type
Simple Report

NE Type
3GRNC

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Calculate AR9725:Average % Subsystem -


EGPU Subsys CPU Usage Measuremen
CP CPU of the Board t
utilizatio
n

Detailed AMR Call (R99) None CS RAB -


Signaling Setup
split Measuremen
t <per Cell>

PS Call (R99) None PS RAB -


Setup
Measuremen
t <per Cell>

PS Call (HSPA) None PS RAB -


Setup
Measuremen
t <per Cell>

NAS RRC None CS RAB -


Setup
Measuremen
t <per Cell>

Soft Handover None Hard -


Addition Handover
Measuremen
t <per RNC>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1215


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Soft Handover None Hard -


Deletion Handover
Measuremen
t <per RNC>

Soft Handover None HSDPA -


Addition+Service Measuremen
Cell Update t <per Cell>

Softer Handover None Soft -


Addition Handover
Measuremen
t <per Cell>

Softer Handover None Soft -


Deletion Handover
Measuremen
t <per Cell>

Hard Handover None Hard -


Handover
Measuremen
t <per RNC>

CS Inter-RAT None CS Inter- -


handover RAT
Handover
Measuremen
t <per RNC>

PS Inter-RAT None PS Inter- -


handover RAT
Handover
Measuremen
t <per RNC>

SRNS Relocation None SRNC -


intra domain Relocation
Measuremen
t

Iu Paging None Paging -


Measuremen
t <per RNC>

Cell update (RL Fail) None Cell Update -


Measuremen
t <per Cell>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1216


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Cell update None Cell Update -


Measuremen
t <per Cell>

DCCC&LDR&STA None RB -
TE TRANS Procedure
Measuremen
t <per Cell>

Compress Mode None Compressed -


Mode
Measuremen
t <per Cell>

DPB None Soft -


Handover
Measuremen
t <per RNC>

DRNC RL SETUP None DRNC -


Measuremen
t per Iur
Interface

DRNC RL RECFG None DRNC -


Measuremen
t per Iur
Interface

DRNC RL ADD None DRNC -


Measuremen
t per Iur
Interface

DRNC RL DEL None DRNC -


Measuremen
t per Iur
Interface

CodeAdj None Algorithm -


Measuremen
t <per Cell>

LCS (A-GPS) None LCS Service -


Measuremen
t <per RNC>

LCS (Non A-GPS) None LCS Service -


Measuremen
t <per RNC>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1217


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

30.9 MPU CPU Utilization Rate of RNC


Report Type
Simple Report

NE Type
3GRNC

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

MPU Average MPU % Traffic -


CPU Subsystem CPU Measuremen
Utilizatio Utilization Rate of t <per RNC>
n Rate of RNC
RNC
Max MPU % Traffic -
Subsystem CPU Measuremen
Utilization Rate of t <per RNC>
RNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1218


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

30.10 Port traffic analysis


Report Type
Simple Report

NE Type
3GRNC

Object Type
FEGE

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Port T7121:Highest kbit/s FE/GE -


traffic Receive Rate of the Ethernet Port
analysis FEGE Ethernet Port Measuremen
t

T7123:Mean kbit/s FE/GE -


Receive Rate of the Ethernet Port
FEGE Ethernet Port Measuremen
t

T7126:Highest kbit/s FE/GE -


Transmit Rate of the Ethernet Port
FEGE Ethernet Port Measuremen
t

T7128:Mean kbit/s FE/GE -


Transmit Rate of the Ethernet Port
FEGE Ethernet Port Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1219


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

30.11 RTWP Breakdown


Report Type
Simple Report

NE Type
3GRNC

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

RTWP UL Background dBm Algorithm -


Breakdo Noise Measuremen
wn t 2 <per Cell>

Power of Totally dBm TX and RX -


Received Bandwidth Power
(Cell) Measuremen
t <per Cell>

UL Total Load % Measuremen -


t of locell
power

DPCCH UL Power % Measuremen -


Load of R99 t of locell
power

DPCCH UL Power % Measuremen -


Load of HSUPA t of locell
10ms power

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1220


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

DPCCH UL Power % Measuremen -


Load of HSUPA 2ms t of locell
power

DPDCH UL Power % Measuremen -


Load of R99 t of locell
power

HSDPCCH UL % Measuremen -
Power Load of t of locell
HSDPA (CQI) power

EDPCCH UL Power % Measuremen -


Load of HSUPA t of locell
10ms power

EDPCCH UL Power % Measuremen -


Load of HSUPA 2ms t of locell
power

EDPDCH UL Power % Measuremen -


Load of HSUPA t of locell
10ms power

EDPDCH UL Power % Measuremen -


Load of HSUPA 2ms t of locell
power

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

30.12 Breakdown Report


Report Type
Simple Report

NE Type
3GRNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1221


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

Calculate SPU Board CPU % XPU -


CPU Utilization Rate Subsystem
utilizatio (Mean) Measuremen
n t

Detailed AMR Call (R99) None CS RAB -


Signaling Setup
split Measuremen
t <per Cell>

PS Call (R99) None PS RAB -


Setup
Measuremen
t <per Cell>

PS Call (HSPA) None PS RAB -


Setup
Measuremen
t <per Cell>

NAS RRC None CS RAB -


Setup
Measuremen
t <per Cell>

Soft Handover None Hard -


Addition Handover
Measuremen
t <per RNC>

Soft Handover None Hard -


Deletion Handover
Measuremen
t <per RNC>

Soft Handover None HSDPA -


Addition+Service Measuremen
Cell Update t <per Cell>

Softer Handover None Soft -


Addition Handover
Measuremen
t <per Cell>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1222


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Softer Handover None Soft -


Deletion Handover
Measuremen
t <per Cell>

Hard Handover None Hard -


Handover
Measuremen
t <per RNC>

CS Inter-RAT None CS Inter- -


handover RAT
Handover
Measuremen
t <per RNC>

PS Inter-RAT None PS Inter- -


handover RAT
Handover
Measuremen
t <per RNC>

SRNS Relocation None SRNC -


intra domain Relocation
Measuremen
t

Iu Paging None Paging -


Measuremen
t <per RNC>

Cell update (RL Fail) None Cell Update -


Measuremen
t <per Cell>

Cell update None Cell Update -


Measuremen
t <per Cell>

DCCC&LDR&STA None RB -
TE TRANS Procedure
Measuremen
t <per Cell>

Compress Mode None Compressed -


Mode
Measuremen
t <per Cell>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1223


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

DPB None Soft -


Handover
Measuremen
t <per RNC>

DRNC RL SETUP None DRNC -


Measuremen
t per Iur
Interface

DRNC RL RECFG None DRNC -


Measuremen
t per Iur
Interface

DRNC RL ADD None DRNC -


Measuremen
t per Iur
Interface

DRNC RL DEL None DRNC -


Measuremen
t per Iur
Interface

CodeAdj None Algorithm -


Measuremen
t <per Cell>

LCS (A-GPS) None LCS Service -


Measuremen
t <per RNC>

LCS (Non A-GPS) None LCS Service -


Measuremen
t <per RNC>

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1224


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

30.13 SPU CPU Utilization Rate of RNC


Report Type
Simple Report

NE Type
3GRNC

Object Type
RNC

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

SPU Average SPU % Traffic -


CPU Subsystem CPU Measuremen
Utilizatio Utilization Rate of t <per RNC>
n Rate of RNC
RNC

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

30.14 TCP Breakdown


Report Type
Simple Report

NE Type
3GRNC

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1225


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

Object Type
UCell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

TCP VS.MeanTCP.NonH dBm TX and RX -


Breakdo S Power
wn Measuremen
t <per Cell>

Common Channel % TX and RX -


Power Power
Measuremen
t <per Cell>

DL Power Ratio of % Measuremen -


SF256 t of locell
power

DL Power Ratio of % Measuremen -


SF128 t of locell
power

DL Power Ratio of % Measuremen -


SF64 t of locell
power

DL Power Ratio of % Measuremen -


SF32 t of locell
power

DL Power Ratio of % Measuremen -


SF16 t of locell
power

DL Power Ratio of % Measuremen -


SF8 t of locell
power

HSDPA Power Ratio % TX and RX -


Power
Measuremen
t <per Cell>

Remaining Power % TX and RX -


Ratio Power
Measuremen
t <per Cell>

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1226


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 30 3G Network Capacity Analysis Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1227


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 31 4G Network Capacity Analysis Report

31 4G Network Capacity Analysis Report

About This Chapter

31.1 eNodeB

31.2 LTE Cell

31.3 LTE Cell Group Traffic Trend Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1228


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 31 4G Network Capacity Analysis Report

31.1 eNodeB

31.1.1 Board

BBP

Report Type
Simple Report

NE Type
4GBTS

Object Type
BBU Board

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

BBP eNodeB BBP CPU % BBU Board -


AVG Utilization Load
Rate Measuremen
t

eNodeB BBP CPU % BBU Board -


MAX Utilization Load
Rate Measuremen
t

Times of eNodeB times BBU Board -


BBP CPU MAX Load
Utilization Rate Measuremen
exceeds threshold t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1229


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 31 4G Network Capacity Analysis Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

MPT

Report Type
Simple Report

NE Type
4GBTS

Object Type
BBU Board

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

MPT eNodeB MPT CPU % BBU Board -


AVG Utilization Load
Rate Measuremen
t

eNodeB MPT CPU % BBU Board -


MAX Utilization Load
Rate Measuremen
t

Times of eNodeB times BBU Board -


MPT CPU MAX Load
Utilization Rate Measuremen
exceeds threshold t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1230


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 31 4G Network Capacity Analysis Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

31.1.2 eNodeB License

RRC-connected User License

Report Type
Simple Report

NE Type
4GBTS

Object Type
eNodeB

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

RRC- RRC-connected User % Measuremen -


connecte License Usage t related to
d User the user
License traffic in
eNodeB for
the operator

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1231


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 31 4G Network Capacity Analysis Report

RRC-connected User License_MOCN

Report Type
Simple Report

NE Type
4GBTS

Object Type
eNodeB Operator

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

RRC- RRC-connected User % Measuremen -


connecte License t related to
d User Usage_MOCN the user
License_ traffic in
MOCN eNodeB for
the operator

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

31.1.3 RscGroup

RscGroup droppkt Ratio

Report Type
Simple Report

NE Type
4GBTS

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1232


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 31 4G Network Capacity Analysis Report

Object Type
RscGroup

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

RscGrou RscGroup Packet % Resource -


p droppkt Loss Ratio Group
Ratio Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

RscGroup Utilization Rate

Report Type
Simple Report

NE Type
4GBTS

Object Type
RscGroup

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

RscGrou RscGroup % Resource -


p Bandwidth Avg Group
Utilizatio Utilization Rate Measuremen
n Rate t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1233


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 31 4G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

RscGroup % Resource -
Bandwidth Peak Group
Utilization Rate Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

31.1.4 eNodeB Traffic Model Report

Report Type
Simple Report

NE Type
4GBTS

Object Type
eNodeB

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

eNodeB PS Call Per User Per times E-RAB -


Traffic BH Setup
Model Measuremen
Report t

S1 Release Per User times E-RAB -


Per BH Release
Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1234


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 31 4G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Intra-eNodeB HO times Outgoing -


Per User Per BH Intra-RAT
Handover
Measuremen
t

Inter-eNodeB HO times Outgoing -


Per User Per BH Intra-RAT
Handover
Measuremen
t

Inter-RAT HO Per times Outgoing -


User Per BH Inter-RAT
Handover
Measuremen
t

RRC ConnReq Fail times RRC Setup -


Per User Per BH Measuremen
t

CSFB Per User Per times Outgoing -


BH Inter-RAT
Handover
Measuremen
t

VOIP Per User Per times E-RAB -


BH Setup
Measuremen
t

TAU Per User Per times RRC Setup -


BH Measuremen
t

Attach Per User Per times RRC Setup -


BH Measuremen
t

Detach Per User Per times RRC Setup -


BH Measuremen
t

Sync State Update times RRC Setup -


per User per BH Measuremen
(Sync-Unsync t
transfer)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1235


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 31 4G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Paging message times Paging -


times Per User Per Measuremen
BH t

Paging response times RRC Setup -


times Per User Per Measuremen
BH t

dedicated eRAB times E-RAB -


Establish Per User Setup
Per BH Measuremen
t

DRX State Update times Cell -


Per User Per BH Algorithm
Measuremen
t

DL experienced Mbit/ Throughput -


Speed s and Data
Volume
Measuremen
t

UL experienced Mbit/ Throughput -


Speed s and Data
Volume
Measuremen
t

DL DataVolume per kbit/s Throughput -


user per BH and Data
Volume
Measuremen
t

UL DataVolume per kbit/s Throughput -


user per BH and Data
Volume
Measuremen
t

DL/UL DataVolum None Throughput -


Ratio and Data
Volume
Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1236


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 31 4G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

DataVolum per user kbit Throughput -


and Data
Volume
Measuremen
t

DL DataVolum per kbit Throughput -


eRAB and Data
Volume
Measuremen
t

UL DataVolum per kbit Throughput -


eRAB and Data
Volume
Measuremen
t

User Data Transfer s Throughput -


Time per User per and Data
BH Volume
Measuremen
t

User SessionTime s Throughput -


per RAB per BH and Data
Volume
Measuremen
t

DL Connected Duty % Throughput -


Ratio Per BH and Data
Volume
Measuremen
t

UL Connected Duty % Throughput -


Ratio Per BH and Data
Volume
Measuremen
t

Spectrum Efficiency None Throughput -


DL and Data
Volume
Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1237


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 31 4G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Spectrum Efficiency None Throughput -


UL and Data
Volume
Measuremen
t

DL Scheduled User % Cell User -


to total user ratio Quantity
Measuremen
t

UL Scheduled User % Cell User -


to total user ratio Quantity
Measuremen
t

Burstness None Cell User -


Quantity
Measuremen
t

Scheduled User to None Cell User -


total user ratio Quantity
Measuremen
t

L.Traffic.User.Avg None Cell User -


Quantity
Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

31.1.5 eNodeB Traffic Trend Report

Report Type
Simple Report

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1238


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 31 4G Network Capacity Analysis Report

NE Type
4GBTS

Object Type
eNodeB

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

eNodeB Online User number None Cell User -


Traffic Quantity
Trend Measuremen
Report t

PS Call Times None E-RAB -


Setup
Measuremen
t

DL Throughput kbit Throughput -


and Data
Volume
Measuremen
t

UL Throughput kbit Throughput -


and Data
Volume
Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

31.2 LTE Cell

31.2.1 Channel

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1239


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 31 4G Network Capacity Analysis Report

PDCCH Utilization Rate(TDD)

Report Type
Simple Report

NE Type
4GBTS

Object Type
LTE Cell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

PDCCH PDCCH Channel % PRB -


Utilizatio AVG Utilization Measuremen
n Rate Rate_CCE (TDD) t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

PDCCH Utilization Rate(FDD)

Report Type
Simple Report

NE Type
4GBTS

Object Type
LTE Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1240


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 31 4G Network Capacity Analysis Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

PDCCH PDCCH Channel % PRB -


Utilizatio AVG Utilization Measuremen
n Rate Rate_CCE (FDD) t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

PRACH Utilization Rate(TDD)

Report Type
Simple Report

NE Type
4GBTS

Object Type
LTE Cell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

PRACH PRACH Channel % RA -


Utilizatio Utilization Measuremen
n Rate Rate_Contention t
Preamble (TDD)

PRACH Channel % RA -
Utilization Measuremen
Rate_Non- t
Contention Preamble
(TDD)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1241


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 31 4G Network Capacity Analysis Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

PRACH Utilization Rate(FDD)

Report Type
Simple Report

NE Type
4GBTS

Object Type
LTE Cell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

PRACH PRACH Channel % RA -


Utilizatio Utilization Measuremen
n Rate Rate_Contention t
Preamble (FDD)

PRACH Channel % RA -
Utilization Measuremen
Rate_Non- t
Contention Preamble
(FDD)

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1242


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 31 4G Network Capacity Analysis Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

31.2.2 PRB Rsc

PRB Utilization Rate(TDD)

Report Type
Simple Report

NE Type
4GBTS

Object Type
LTE Cell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

PRB UL PRB Used AVG % PRB -


Utilizatio Utilization Rate Measuremen
n Rate (TDD) t

DL PRB Used AVG % PRB -


Utilization Rate Measuremen
(TDD) t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1243


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 31 4G Network Capacity Analysis Report

PRB Utilization Rate(FDD)

Report Type
Simple Report

NE Type
4GBTS

Object Type
LTE Cell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

PRB UL PRB Used AVG % PRB -


Utilizatio Utilization Rate Measuremen
n Rate (FDD) t

DL PRB Used AVG % PRB -


Utilization Rate Measuremen
(FDD) t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

PRB Utilization Rate_MOCN(TDD)

Report Type
Simple Report

NE Type
4GBTS

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1244


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 31 4G Network Capacity Analysis Report

Object Type
Operator

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

PRB UL PRB Used % PRB -


Utilizatio Utilization Measuremen
n Rate Rate_MOCN (TDD) t per
CNOperator

DL PRB Used % PRB -


Utilization Measuremen
Rate_MOCN (TDD) t per
CNOperator

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

PRB Utilization Rate_MOCN(FDD)

Report Type
Simple Report

NE Type
4GBTS

Object Type
Operator

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1245


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 31 4G Network Capacity Analysis Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

PRB UL PRB Used % PRB -


Utilizatio Utilization Measuremen
n Rate Rate_MOCN (FDD) t per
CNOperator

DL PRB Used % PRB -


Utilization Measuremen
Rate_MOCN (FDD) t per
CNOperator

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

31.2.3 VoIP

VoIP User Utilization Rate(TDD)

Report Type
Simple Report

NE Type
4GBTS

Object Type
LTE Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1246


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 31 4G Network Capacity Analysis Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

VoIP VoIP User % E-RAB -


User Utilization Rate Setup
Utilizatio (TDD) Measuremen
n Rate t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

VoIP User Utilization Rate(FDD)

Report Type
Simple Report

NE Type
4GBTS

Object Type
LTE Cell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

VoIP VoIP User % E-RAB -


User Utilization Rate Setup
Utilizatio (FDD) Measuremen
n Rate t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1247


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 31 4G Network Capacity Analysis Report

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

31.2.4 LTE Cell Traffic Model Report

Report Type
Simple Report

NE Type
4GBTS

Object Type
LTE Cell

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

LTE Cell PS Call Per User Per times E-RAB -


Traffic BH Setup
Model Measuremen
Report t

S1 Release Per User times E-RAB -


Per BH Release
Measuremen
t

Intra-eNodeB HO times Outgoing -


Per User Per BH Intra-RAT
Handover
Measuremen
t

Inter-eNodeB HO times Outgoing -


Per User Per BH Intra-RAT
Handover
Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1248


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 31 4G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

Inter-RAT HO Per times Outgoing -


User Per BH Inter-RAT
Handover
Measuremen
t

RRC ConnReq Fail times RRC Setup -


Per User Per BH Measuremen
t

CSFB Per User Per times Outgoing -


BH Inter-RAT
Handover
Measuremen
t

VOIP Per User Per times E-RAB -


BH Setup
Measuremen
t

TAU Per User Per times RRC Setup -


BH Measuremen
t

Attach Per User Per times RRC Setup -


BH Measuremen
t

Detach Per User Per times RRC Setup -


BH Measuremen
t

Sync State Update times RRC Setup -


per User per BH Measuremen
(Sync-Unsync t
transfer)

Paging response times RRC Setup -


times Per User Per Measuremen
BH t

dedicated eRAB times E-RAB -


Establish Per User Setup
Per BH Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1249


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 31 4G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

DRX State Update times Cell -


Per User Per BH Algorithm
Measuremen
t

DL experienced Mbit/ Throughput -


Speed s and Data
Volume
Measuremen
t

UL experienced Mbit/ Throughput -


Speed s and Data
Volume
Measuremen
t

DL DataVolume per kbit/s Throughput -


user per BH and Data
Volume
Measuremen
t

UL DataVolume per kbit/s Throughput -


user per BH and Data
Volume
Measuremen
t

DL/UL DataVolum None Throughput -


Ratio and Data
Volume
Measuremen
t

DataVolum per user kbit Throughput -


and Data
Volume
Measuremen
t

DL DataVolum per kbit Throughput -


eRAB and Data
Volume
Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1250


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 31 4G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

UL DataVolum per kbit Throughput -


eRAB and Data
Volume
Measuremen
t

User Data Transfer s Throughput -


Time per User per and Data
BH Volume
Measuremen
t

User SessionTime s Throughput -


per RAB per BH and Data
Volume
Measuremen
t

DL Connected Duty % Throughput -


Ratio Per BH and Data
Volume
Measuremen
t

UL Connected Duty % Throughput -


Ratio Per BH and Data
Volume
Measuremen
t

Spectrum Efficiency None Throughput -


DL and Data
Volume
Measuremen
t

Spectrum Efficiency None Throughput -


UL and Data
Volume
Measuremen
t

DL Scheduled User % Cell User -


to total user ratio Quantity
Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1251


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 31 4G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

UL Scheduled User % Cell User -


to total user ratio Quantity
Measuremen
t

Burstness None Cell User -


Quantity
Measuremen
t

Scheduled User to None Cell User -


total user ratio Quantity
Measuremen
t

L.Traffic.User.Avg None Cell User -


Quantity
Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

31.2.5 LTE Cell Traffic Trend Report

Report Type
Simple Report

NE Type
4GBTS

Object Type
LTE Cell

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1252


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 31 4G Network Capacity Analysis Report

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

LTE Cell Online User number None Cell User -


Traffic Quantity
Trend Measuremen
Report t

PS Call Times None E-RAB -


Setup
Measuremen
t

DL Throughput kbit Throughput -


and Data
Volume
Measuremen
t

UL Throughput kbit Throughput -


and Data
Volume
Measuremen
t

DL experienced Mbit/ Throughput -


Speed s and Data
Volume
Measuremen
t

UL experienced Mbit/ Throughput -


Speed s and Data
Volume
Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1253


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 31 4G Network Capacity Analysis Report

31.3 LTE Cell Group Traffic Trend Report


Report Type
Simple Report

NE Type
4GBTS

Object Type
LTE Cell Group

Subreport Information
Subrep Counter Coun Function Formula
ort ter Subset
Name Unit

LTE Cell Online User number None Cell User -


Group Quantity
Traffic Measuremen
Trend t
Report
PS Call Times None E-RAB -
Setup
Measuremen
t

DL Throughput kbit Throughput -


and Data
Volume
Measuremen
t

UL Throughput kbit Throughput -


and Data
Volume
Measuremen
t

DL experienced Mbit/ Throughput -


Speed s and Data
Volume
Measuremen
t

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1254


Copyright © Huawei Technologies Co., Ltd.
PRS
Performance Report Reference 31 4G Network Capacity Analysis Report

Subrep Counter Coun Function Formula


ort ter Subset
Name Unit

UL experienced Mbit/ Throughput -


Speed s and Data
Volume
Measuremen
t

NOTE

To obtain the information about the previous counters, use the following methods:
l Checking the counter type. You can open KPI Management to check whether those counters are
system counters or custom counters.
l For system counters, refer to NE Reference Information in PRS Online Help.
l For custom counters, you can find the corresponding expressions in the KPI Management window,
and then read the description of each system counter in NE Reference Information in PRS Online
Help.

Issue 01 (2015-05-30) Huawei Proprietary and Confidential 1255


Copyright © Huawei Technologies Co., Ltd.

Você também pode gostar