Você está na página 1de 16

Modular Digital Telemetry

90478, 90479
Technical Reference
070-0436-00 Rev. G

more time to care


© 2004 Spacelabs Medical, Inc.

All rights reserved. Contents of this publication may not be reproduced in any form without the written permission of Spacelabs
Medical. Products of Spacelabs Medical are covered by U.S. and foreign patents and/or pending patents. Printed in U.S.A.
Specifications and price change privileges are reserved.
Spacelabs Medical considers itself responsible for the effects on safety, reliability and performance of the equipment only if:

• assembly operations, re-adjustments, modifications or repairs are carried out by persons authorized by Spacelabs
Medical, and
• the electrical installation of the relevant room complies with the requirements of the standard in force, and
• the equipment is used in accordance with the operations manual.

Spacelabs Medical will make available, on request, such circuit diagrams, component part lists, descriptions, calibration instructions
or other information which will assist appropriately qualified technical personnel to repair those parts of the equipment which are
classified by Spacelabs Medical as field repairable.
Spacelabs Medical is committed to providing comprehensive customer support beginning with your initial inquiry through purchase,
training, and service for the life of your Spacelabs Medical equipment.

CORPORATE OFFICES

U.S.A.

Spacelabs Medical
5150 220th Ave SE
Issaquah, WA 98029
Telephone: 425-657-7200
Telephone: 800-522-7025
Fax: 425-657-7212

Authorized EC Representative
UNITED KINGDOM

Spacelabs Limited
71 Great North Road, Hatfield
Herts AL9 5EN
Telephone: 44-1707-263-570
Fax: 44-1707-260-065

BirthNet, Data Shuttle, Flexport, Intesys Clinical Suite, Maternal Obstetrical Monitor, MOM, Mermaid, Multiview, PCIS, PCMS,
PrintMaster, Quicknet, Sensorwatch, TRU-CAP, TRU-CUFF, TRU-LINK, UCW, Ultralite, Ultraview, Ultraview Clinical Messenger,
Ultraview SL, Uni-Pouch, Universal Flexport, Varitrend and WinDNA are trademarks of Spacelabs Medical, Inc.

Other brands and product names are trademarks of their respective owners.

CAUTION:
Rx US Federal law restricts the devices documented herein to sale by, or on the order
Only of, a physician.
Table of Contents

Chapter Page

Introduction
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1

Drawings
Schematics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1

Symbols

i
Introduction

Contents
Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Overview
This technical reference manual provides schematics for Modular Digital Telemetry. Refer to the
Modular Digital Telemetry Service Manual (P/N 070-0435-xx, which is located on CD-ROM 084-
0700-xx) for the assembly drawings and field-replaceable parts list.
Spacelabs Medical’s products are designed and manufactured under good manufacturing practices
and in compliance with all applicable regulatory requirements. To ensure proper operation in
accordance with these guidelines, this product must be maintained by trained technicians using
Spacelabs Medical authorized replacement parts.

1-1
Drawings

Contents
Schematics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Schematics
Title Part Number Drawing Number

Transmitter VHF PCBA (single and dual lead) Refer to table 1 Refer to table 1

Transmitter UHF PCBA (single and dual lead) 670-0574-00 1 (1 sheet)

Transmitter UHF PCBA (quad lead) 670-0482-01 2 (1 sheet)

Transmitter ECG PCBA (single lead) 676-0193-00 5 (1 sheet)

Transmitter ECG PCBA (dual lead) 670-0573-03 6 (1 sheet)

Transmitter ECG PCBA (quad lead) 670-0285-01 7 (1 sheet)

90478 Power Supply PCBA 670-0619-00 8 (1 sheet)

90478 Digital PCBA 670-0617-01 9 (3 sheets)

90478 Antenna PCBA 670-0723-00 10 (1 sheet)

90478 RF PCBA Refer to table 3 Refer to table 3

90478 CPU PCBA 670-0724-01 12 (2 sheets)

90479 Dual Preamp PCBA 670-0710-00 13 (1 sheet)

90479 Dual Backplane PCBA 670-0750-00 14 (1 sheet)

90479 Power Supply PCBA 670-0448-05 15 (13 sheets)*

90479 Power Distribution Assembly 670-0756-00 16 (1 sheet)

* Sheets begin with page number 3. Pages 1 and 2 are not schematics.

2-1
Modular Digital Telemetry

CAUTION:
• Observe precautions for handling electrostatic-sensitive devices!

Table 1: Transmitter PCBA (Single and Dual Leads)

Transmitter Model RF PCBA Drawing Number


90339-33/90341 (UHF) 670-0574-00 1
90340-10 (UHF) 670-0482-01 2
90339-16/90341-16 (VHF HIGH) 670-0629-00 3
90339-74/90341-74 (VHF LOW) 670-0628-00 4

Table 2: Transmitter ECG PCBA (Single Lead)

Transmitter Model ECG PCBA Drawing Number


90339-xx 670-9008-00 5
90341-xx 670-0573-03 6
90340-10 670-0285-01 7

Table 3: 90478 Receiver

Frequency Band RF PCBA Drawing Number


U: 460-470 MHz 670-0618-03
G: 430-442 MHz 670-0837-00
R: 455-460 MHz 670-8825-00
I: 470-480 MHz 670-8824-00
J: 174-180 MHz 670-0821-00
11
K: 180-186 MHz 670-0821-00
P/N 676-0088-00
L: 186-192 MHz 670-0821-00
M: 192-198 MHz 670-0821-00
N: 198-204 MHz 670-0821-00
O: 204-210 MHz 670-0821-00
P: 210-216 MHz 670-0821-00

2-2
Symbols
The following list of international and safety symbols describes all symbols used on Spacelabs Medical products. No one
product contains every symbol.

Symbol Description Symbol Description

HELP Key Keyboard Connection

SPECIAL FUNCTIONS Key Mouse connection

RECORD Key START/STOP Key

NORMAL SCREEN Key START/STOP

MONITOR SETUP Key STOP or CANCEL Key

ALARMS Key CONTINUE Key

PREVIOUS MENU Key ENTER Key

OFF — Power Disconnection from


ON — Power Connection to Mains
Mains

ON Position for Push Button Power OFF Position for Push Button Power
Switch Switch

On Direction ON/OFF

Television; Video Display Video Output

ON — Part of the Instrument Only OFF — Part of the Instrument Only

3-1
Modular Digital Telemetry

Symbol Description Symbol Description

Stand-by STAND-BY Key

PAUSE or INTERRUPT Slow Run

Reset Power Indicator LED

Temporary Shut Off of Alarm Tone or


Alarm
Screen Indicators

Indicator — Remote Control Indicator — Local Control

PRINT REPORT Key Indicator — Out of Paper

Partial ON/OFF Recorder Paper

1
2
1
Normal Screen 3
2
3
Return to Prior Menu

Clock/Time Setting Key TREND/TIMER Key

? HELP (Explain Prior Screen) Key Keypad

Activate Recorder for Graphics Indoor Use Only

START (NIBP) Key Auto Mode (NIBP)

Output No Output (Terminated)

3-2
Symbols

Symbol Description Symbol Description

Data Input/Output Input/Output

Input Reset

Menu Keys Waveform/Parameter Keys

1 Monitor Setup 1
2 2 A Set Initial Conditions Menu
3 Select Program Options 3

1 1
2 B Access Special Function Menu 2 Return Unit to Monitor Mode
3 3

1 Serial Port 1 2 Serial Port 2

External marker push button connection SDLC SDLC Port

Electrocardiograph or
Arterial Pulse
Defibrillator Synchronization

Gas Exhaust Foot Switch

Enlarge, Zoom x Delete

PCMCIA Card Event

Keep Dry Fragile; handle with care

12,200 m
Environmental Shipping/Storage Altitude
This Way Up
Limitations

3-3
Modular Digital Telemetry

Symbol Description Symbol Description

Environmental Shipping/Storage Environmental Shipping/Storage


Temperature Limitations Humidity Limitations

Open Padlock Closed Padlock

Down Arrow Up Arrow

Hard Drive Power Indicator LED

Antenna Mermaid Connector

Microphone Omnidirectional Microphone

Audio Output, Speaker Activate Telemetry Recorder

Network Connection Universal Serial Bus

Gas Sampling Port Gas Return Port

Remote Alarm; Nurse Alert Nurse Call

Battery Status Low Battery

Battery Replace only with the appropriate


Replace only with the appropriate battery.
battery. (+ / - signs may be reversed)

3-4
Symbols

Symbol Description Symbol Description


All batteries should be disposed of
properly to protect the environment.
Caution - hazardous voltages. To reduce
Lithium batteries should be fully
risk of electric shock, do not remove the
discharged before disposal. Batteries
cover or back. Refer servicing to a
such as lead-acid (Pb) and nickel-
qualified service personnel (U.S.A.).
cadmium (Ni-Cd) must be recycled.
Please follow your internal procedures
DANGER - High Voltage (International)
and or local (provincial) laws regarding
disposal or recycling.

Protective Earth Ground Functional Earth Ground

Replace Fuse Only as Marked Fuse

Power supply jack polarity.


Equipotentiality Terminal
(+ / - signs may be reversed)

Alternating Current Direct Current

Both Direct and Alternating Current AC/DC Input

A Amperes
Hz Hertz

V Volts
W Watts

IEC 601-1 Type B equipment. The unit


displaying this symbol contains an
Class II Equipment
adequate degree of protection against
electric shock.

IEC 601-1 Type BF equipment which is


defibrillator-proof. The unit displaying IEC 601-1 Type BF equipment. The unit
this symbol contains an F-type isolated displaying this symbol contains an F-
(floating) patient-applied part which type isolated (floating) patient-applied
contains an adequate degree of part providing an adequate degree of
protection against electric shock, and is protection against electric shock.
defibrillator-proof.

3-5
Modular Digital Telemetry

Symbol Description Symbol Description


IEC 601-1 Type CF equipment. The unit
IEC 601-1 Type CF equipment. The unit
displaying this symbol contains an F-
displaying this symbol contains an F-
type isolated (floating) patient-applied
type isolated (floating) patient-applied
part providing a high degree of
part providing a high degree of
protection against electric shock, and is
protection against electric shock.
defibrillator-proof.

Loop Filter Adult NIBP

Canadian Standards Association


ETL Laboratory Approved ® Approved
C US
Risk of Explosion if Used in the
Presence of Flammable Anesthetics ! Operates on Non-Harmonized Radio
Frequencies in Europe

Attention - Consult Operations or


Note Note ! Service Manual for Description

Warning About Potential Danger to Caution About Potential Danger to a


WARNING CAUTION
Human Beings Device

Noninvasive Blood Pressure (NIBP),


Fetal Monitor Connection (Analog)
Neonate

Fetal Monitor Connection Physiological Monitor Connection


RS232 (Digital) RS232 (Digital)

Happy Face Sad Face

Magnifying Glass Compression

File Cabinet List of Rooms

Arrows Printer

Recycle Service Message

3-6
Symbols

Symbol Description Symbol Description

Radio transmitting device; elevated


levels of non-ionizing radiation

Abbreviations used as symbols are shown below.

Symbol Description Symbol Description

Access Codes
1 - 32 AIR Air
1 Through 32

ANT 1 Diversity Antenna System 1 Arr1 Arrhythmia Net 1


ANT 2 Diversity Antenna System 2 ArrNet2 Arrhythmia Net 2

EEG, EMG, or ECG Channel


CH
EEG Channels - CH1, CH2, CH3, CH4 cmH2O Centimeters of Water
ch
EMG Channel - CH5

C.O.
DIA
CO Cardiac Output Diastolic
dia
co

ECG EEG
Electrocardiogram Electroencephalogram
ecg eeg

EMG Electrosurgical Interference


Electromyogram ESIS
emg Suppression

EXT External FECG Fetal Electrocardiogram

FHR1 Fetal Heart Rate, Channel 1 GND


Patient Isolated Ground
FHR2 Fetal Heart Rate, Channel 2 gnd

HLO
High-Level Output Multiview Multi-Lead Electrocardiogram
hlo

NIBP
Noninvasive Blood Pressure N2O Nitrous Oxide
nibp

PRESS
O2 Oxygen press Pressure
PRS

3-7
Modular Digital Telemetry

Symbol Description Symbol Description

RESP
Respiration SDLC Synchronous Data Link Control
resp

SPO2
SVO2
SpO2 Arterial Oxygen Saturation
SvO2 Mixed Venous Oxygen Saturation
SpO2 as Measured by Pulse Oximetry
SvO2
SaO2

T1 Temperature 1
SYS T2 Temperature 2
Systolic
sys T3 Temperature 3
T4 Temperature 4

TEMP
Temperature UA Uterine Activity or Umbilical Artery
temp

VAC Vacuum Connection

3-8