Problem
40X7594; Main drive module failure; Preventing motor overheat;
Solution
Audience: ‘Lexm ark and Partners’ only below
4063 – xxx
Machine Type/Model
7463 – xxx
Possible early failure
Date Created 08/27/2013 of the Main drive motor
due to overheating
Last Updated 09/16/2013
Safety Issue? No
Code Update? No Solution
Engineering Change? No
Remove the black tape
New Parts? No covering the motor
Old Parts Status n/a before installing.
Voltage: 120/240 All
Serial No. Range All
Overview
This service tip is essential whenever you are replacing the Main drive motor (PN: 40X7594) of the
following Lexmark single-function and multi-function devices: MS71x, MS81x, M5155, M5163, M5170,
MX71x, MX81x, XM5163, XM5170, XM71xx.
https://support.lexmark.com/index?pmv=print&page=content&locale=en&productCode=&segment=SUPPORT&clearQuestion=Y&userlocale=EN_US&id=… 1/2
24/10/13 Lexmark United States Main Drive Motor Installation Tip
The Main drive motor, with field replaceable unit (FRU) part number 40X7594, comes with a black tape
covering the motor should you order it from Lexmark Parts Center. This black tape prevents any foreign
material from getting into the motor through the air vents. See image below.
IMPORTANT! Do not forget to remove the black tape before installing the Main drive motor into the printer.
Leaving the tape on will block the air vents, causing the motor to run hotter during printing process and may
consequently lead to early failure.
Additional information
Make sure to keep the front door closed when installing the Main drive motor to prevent breaking the left-
side front door hinge pivot. Please see Technical Service Bulletin: TE510 for more information.
If necessary, refer to the printer’s Service Manual for more a detailed removal/replacement procedure. If
further assistance is required, contact your next level of support or Lexmark Technical Support.