Você está na página 1de 2

Mk6N

Smart Three Phase


Electronic Revenue Meter
Genius Series - Class 0.5S, Class 1 and Class 2

PRODUCT INFORMATION

Utilizing the same advanced meter design and


firmware platform as the original Mk6, the new Mk6N
meter updates this platform to address new IEC
standards and to incorporate an updated power
supply and input protection technology utilized by our
latest range of energy meters.

KEY FEATURES

AMI READY HIGH LARGE LARGE MEASURE UPGRADEABLE ANTI SCRIPT


ACCURACY DATA STORAGE LCD DISPLAY EVERYTHING TAMPER EXTENSIONS
Mk6N Genius Series - Class 0.5S, Class 1 and Class 2

Smart Three Phase


Electronic Revenue Meter
SPECIFICATIONS
Measurement •Mains synchronised or internal • Interval programmable from 1 second pre-programmed alarms based
crystal (TCXO) time keeping. Mains to 1 month on numerous:
• Class 0.5S, Class 1 and Class 2
synchronised reverts to internal crystal • Multiple independent surveys • Self-checks
• IEC62052-11, IEC62053-21 (Class 1), (TCXO) on loss of all on all phase volts
IEC62053-22 (Class 0.5S), • Energy, instantaneous readings and • Tamper and wiring checks
IEC62053-23 (Class 2) Data Storage pulsing inputs as potential survey
channel sources These alarms can:
• 1 phase (3 circuits) •C
 onfiguration, TOU data and load • Turn on LED, LCD indicator or relay
• Ability to store average/minimum/
• 3 phase 3 wire survey data maximum values over interval duration output
• 3 phase 4 wire - Flash RAM for individual channels • Record an event in the event log
- Battery backed up RAM • Trigger an event such as a remote
Voltage Time of Use
alarm, dial an emergency number,
• Nominal voltage: 57V - 240V LCD Display • 8 rates plus unified rate send an SMS to a programmable
(phase to neutral) •16 Characters by 2 lines alphanumeric • Up to 12 separate import and export number or send alarm messages via
• Burden: <10VA per phase @ Vn display registers GPRS to a programmable server
(3 phase), as per IEC 62053-61 •Programmable units, multipliers and •Up to 200 programmable special days
leading zeros Communications
Current •Daily, weekly, monthly, yearly and
• Up to 64 user-defined screen displays special days •U
 p to 3 independently working
• CT range: 1/1.2A, 1/2A, 1/4A, 1/6A, • Displays any available meter communications ports:
5/6A, 5/10A and 5/20A • 13 or more previous periods
parameter - Optical port: FLAG (IEC 62056-21)
•WC range: 10/100A, 20/100A and • Block or rolling maximum demand
Measured Values • Time of maximum demand or ANSI Type 2 (ANSI C12.18)
25/100A (Class 1 only)
• Configurable billing reset button - RS-232 (RTS/CTS and DTR/DCD)
•Short time over-current: 20 x Imax for • 3 elements, 4 quadrants
0.5 seconds - RS-485 multi-drop (4-wire with
• Import/Export/Absolute Wh, varh and Extensions for Customer
VAh RJ45 or screw terminal)
• Burden: <0.5VA/phase Applications
• Phase A, B, C or Total • Option for SCADA card
Auxiliary Supply Options The Mk6N inherits the ability to use
• W, var, VA extensions to increase the functionality • Option for internal modem power
•100 to 240 VAC
• True RMS voltage (3 phase) of the standard metering platform. A supply
Frequency • True RMS current (3 phase) simple yet powerful scripting language • PSTN, UDP/IP, GPRS/PPP capable
allows complex register manipulations
• 45Hz - 65Hz • Power factor • Compatible with MV-90TM
to be performed that can create
• Frequency • Support EDMI command line and
Inputs/Outputs Configuration customized functions within the
• Phasor angles meter without the need for a firmware
• Up to 8 I/O via optional extended I/O MODBUS protocol
upgrade. EDMI is always developing
card Quality of Supply Features • Master/Slave arrangement with up
new extensions and we offer custom
• Active input: 5V to 31 ‘Slave” meters accessed
• Total Harmonic Distortion (THD) extension creation for specific customer
• Additional passive input, SO, BOSFET needs. Contact us to find out more through one ‘Master’ gateway meter
• Unbalance
or relay outputs in the extended I/O about extensions for the Genius range
• Fundamental voltage, current and Software
card of meters.
watt measurement • EziView Windows® software
• Passive input voltage: Some examples of currently available
• Harmonics (up to the 50th) (optional), can be used for
5V, 12V, 48V, 110V, 240V extensions are: programming and reading the meter
• BOSFET output: • Sag/Swell
• Send SMS at percentage of maximum • EziView also allows offline
240V, 100mA maximum - 5 cycle resolution demand configuration of tariff programs and
• SO output: 1.2V, 20mA maximum -R
 ecords time/date/phase/ • Average power factor for billing period all meter parameters, for later upload
• Relay output: 240V, 5A duration/worst excursion • LCD menu system to meters
• 2 Programmable LED indicators - Programmable trigger levels • Magnetic tamper detection Environmental
• Programmable output pulse width: • Waveform capture (voltage and • Power factor control extension • Specified operating range:
1ms to 250ms • Maximum demand control of loads via
current only) -25°C to +60°C
• Programmable output polarity pulsing outputs
• Time synchronised (optional) Load Survey/Profile • Storage range limit:
• Average voltage/current/unbalance,
THD, etc. -25°C to +80°C
Battery • NEM compliant
• Voltage Sag/Swell or power outage • Relative humidity:
• Backup type: Optional lithium battery • Over 900 kilobytes of flash data
storage space • Voltage quality up to 95% non-condensing
1200mAh, 3.5V and SuperCap (single/
dual) - 3100 day-channel capacity at 30 • Send SMS/GPRS alarm on equipment
Dimensions and Weight
• Backup time: 2 years without power minute intervals failure alarm
- 1875 day capacity at 30 minute • Detect individual phase VT failures • Dimensions: 260mm (L) x
• Battery shelf life of 10 plus years at
intervals/2 channels 173mm (W) x 93mm (D)
room temperature
- 520 day capacity at 15 minute
Equipment Failure Alarms
(EFAs) • Weight: 2 kg (standard), 2.2 kg
Real-time Clock intervals/3 channels
A single user defined alarm condition (with SCADA card)
• Accuracy: 0.5 seconds per day (over • Up to 50 channels
(via extensions) is available plus
full temperature range)

EDMI Limited
47 Yishun Industrial Park A, Singapore 768724
Tel: +65 6756 2938 | Fax: +65 6756 0125
Email: sgmarketing@edmi-meters.com | sgtechsupport@edmi-meters.com www.edmi-meters.com

Copyright © 2016 EDMI Limited. All Rights Reserved. All trademarks are the property of their respective holders. EDMI’s Policy is one of continuous product development and the right is reserved to modify specifications contained herein without notice.
MKT-BR-018 Rev 00