Você está na página 1de 3

Asugonj Power Station Company Ltd.

Written examination for the post of Sub Assistant Engineer(Electrical)

Full marks:70 Time: 1 hour

Model test-01 (Department)

01. I= 4 cos (wt+30) A and V= 5 sin (wt-20) V state which sinusoid is leading ? 07

02. Find the equivalent resistance for the following ckt. 07

03. Draw the wave shape of V out. 07

04. Draw the thevenin,s equivalent ckt across the terminal A,B 07
05. What is the maximum efficiency of 100 KVA transformer if core loss is 900W and full load
copper loss is 1600 W ? 07

06. A 400 V shunt motor has armature resistance of 0.8 ohm and field Resistance of 200 ohm.
Determine the back e.m.f when giving on output of 7.46 KW at 85% efficiency. 07

07. A 132 KV transmission line has the following data:


Wt. of conductor = 680kg/km; length of span=260 m.
Ultimate strength=3200 kg; safety factor=02.
Calculate the height above ground at which the conductor should be supported. Ground clearance
required is 10 m. 07

Organized by: EEE GROUP STUDY


Facebook: https://www.facebook.com/groups/1200246770062798/
08. An insulator string consist of three units each having a safe working voltage of 15 KV. The ratio
of self-capacitance to shunt capacitance of each unit is 8:1. Find the maximum safe working
voltage of the string. 07

09. Explain the work principle of CE amplifier 07

10. A consumer has a maximum demand of 200KW at 40% load factor. If the tariff is TK.100 per
KW of maximum demand plus 10 paisa KWh, find the overall cost per KWh. 07

Organized by: EEE GROUP STUDY


Facebook: https://www.facebook.com/groups/1200246770062798/

Você também pode gostar