Você está na página 1de 10

MOBILETT XP

MOBILETT XP Hybrid
The New Dimension in Mobile X-ray Imaging
Beyond your expectations in mobile X-ray imaging

The name MOBILETT has become synonymous with MOBILETT XP is ideally suited for all applications
excellence in mobile X-ray imaging. Siemens Medical in the ICU, neonatal and pediatric departments or
Solutions now offers MOBILETT XP – the new platform in the ward.
of mobile X-ray systems with virtually unlimited
MOBILETT XP, the new dimension in mobile X-ray
imaging power. The new MOBILETT XP features
imaging, provides maximum utilization potential with
up to 10 times more imaging power. It easily handles
its outstanding power, improved clinical workflow
the most demanding clinical situations including
capabilities, and flexibility in patient positioning.
abdominal and chest imaging even for very obese
MOBILETT XP features optimal range and freedom of
patients.
positioning – anywhere and anytime.

The advanced mobile X-ray system, MOBILETT XP


Hybrid combines battery-assisted motor-drive with
dual source power for exposures providing highest
comfort in mobile imaging.

Attractive “giraffe
look” accessories.
Cheerfulness and
relax the exam.

2
3
Designed to make a difference

MOBILETT XP is highly mobile. Developed with


increased imaging power for heavy duty use in busy
hospital environments, MOBILETT XP is ideally suited
for the most demanding mobile imaging tasks.

The self-calibrating high imaging output – up to


30 kW and 360 mAs – enables short exposure times
down to 1 ms virtually eliminating any motion
blurring. Although MOBILETT XP supports a wide
range of applications, the remarkably sharp images
made possible by the short exposure times enhance
its utility in coronary care and neonatal units.
In addition, the MOBILETT XP’s small footprint and
hidden cable design – for easy, efficient cleaning –
are clear advantages. MOBILETT XP is the ideal choice
for semi-sterile environments such as ICU, CCU,
neonatal as well as pediatric departments or the ward.

Hand switch

4
Arm can be
easily moved in any
position

The new lightweight design of MOBILETT XP


makes it easy for the operator to move the
system effortlessly. A convenient handbrake
on the chassis allows the system to safely come
to a halt exactly when and where necessary.
Since MOBILETT XP is the lightest system in its
class, it offers outstanding maneuverability
around beds and other equipment.

The platform’s short wheelbase with


polyurethane tires help to overcome rolling
resistance, allowing the system to glide easily
on most surfaces. Offering a wide usable
arm range – with a double, articulated,
counterbalanced swivel arm system –
MOBILETT XP can easily be positioned for
imaging in all conceivable projections with
the patient recumbent, sitting, or any position
in between. Since the unit’s head can be freely
rotated, all types of projections are easy to
adjust – from either side of the bed.

5
MOBILETT XP Hybrid –
battery assisted and higher flexibility

For additional operator convenience or special


transport conditions – such as steep inclinations, door
thresholds, or thick floor carpets – the motor-assisted
feature of the MOBILETT XP Hybrid provides additional
advantages.

Power for imaging with MOBILETT XP Hybrid can


come from either its long-life rechargeable batteries
or from a conventional wall power outlet, providing
maximum flexibility even when the batteries are
discharged.

6
MOBILETT XP/MOBILETT XP Hybrid
Technical Data

X-ray Controls & Generator MOBILETT XP MOBILETT XP Hybrid


Power connection: Grounded wall outlet Grounded wall outlet
Mains voltage: 100 – 130 V ±10%, 50/60 Hz, fuse 15 A 100 – 130 V ±10%, 50/60 Hz, fuse 15 A
200 – 240 V ±10%, 50/60 Hz, fuse 15 A 200 – 240 V ±10%, 50/60 Hz, fuse 15 A

Apparent resistance of 100 – 130 V < 0.6 Ohm 100 – 130 V < 0.6 Ohm
supply mains: 200 – 240 V < 2.5 Ohm 200 – 240 V < 2.5 Ohm

Output: 30 kW at 96 kV 10 ms 30 kW at 96 kV 10 ms
25 kW at 102 kV 100 ms 25 kW at 102 kV 100 ms
(acc. to IEC 601-2-7/1987) (acc. to IEC 601-2-7/1987)
133 kV (max.), 450 mA (max.) 133 kV (max.), 450 mA (max.)
kVp-range: 40 – 133 kV in 24 or 47 steps 40 – 133 kV in 24 or 47 steps
kV accuracy: < ±3 kV (40 – 60 kV) < ±3 kV (40 – 60 kV)
< ±5% (60 – 133 kV) < ±5% (60 – 133 kV)

mAs-range: At 40 – 55 kV: mAs 0.32 – 200 At 40 – 55 kV: mAs 0.32 – 200


(Tube current and At 57 – 60 kV: mAs 0.32 – 180 At 57 – 60 kV: mAs 0.32 – 180
exposure time product) At 63 – 68 kV: mAs 0.32 – 160 At 63 – 68 kV: mAs 0.32 – 160
Mains operation 230 V At 70 – 77 kV: mAs 0.32 – 140 At 70 – 77 kV: mAs 0.32 – 140
At 81 – 88 kV: mAs 0.32 – 125 At 81 – 88 kV: mAs 0.32 – 125
At 90 – 99 kV: mAs 0.32 – 110 At 90 – 99 kV: mAs 0.32 – 110
At 102 – 109 kV: mAs 0.32 – 100 At 102 – 109 kV: mAs 0.32 – 100
At 117 kV: mAs 0.32 – 90 At 117 kV: mAs 0.32 – 90
At 125 – 133 kV: mAs 0.32 – 80 At 125 – 133 kV: mAs 0.32 – 80

mAs-range: At 40 – 55 kV: mAs 0.32 – 140 At 40 – 55 kV: mAs 0.32 – 140


(Tube current and At 57 – 60 kV: mAs 0.32 – 125 At 57 – 60 kV: mAs 0.32 – 125
exposure time product) At 63 – 70 kV: mAs 0.32 – 110 At 63 – 70 kV: mAs 0.32 – 110
Mains operation 110 V At 70 – 77 kV: mAs 0.32 – 100 At 70 – 77 kV: mAs 0.32 – 100
At 81 – 85 kV: mAs 0.32 – 90 At 81 – 85 kV: mAs 0.32 – 90
At 90 – 96 kV: mAs 0.32 – 80 At 90 – 96 kV: mAs 0.32 – 80
At 99 – 117 kV: mAs 0.32 – 63 At 99 – 117 kV: mAs 0.32 – 63
At 125 – 133 kV: mAs 0.32 – 56 At 125 – 133 kV: mAs 0.32 – 56
mAs-range: At 40 – 81 kV: mAs 0.32 – 360
(Tube current and At 83 – 90 kV: mAs 0.32 – 320
exposure time product) At 96 – 102 kV: mAs 0.32 – 280
Battery Operation for At 109 – 117 kV: mAs 0.32 – 250
MOBILETT XP Hybrid At 133 kV: mAs 0.32 – 220
mAs accuracy: ±5% ±5%
Shortest exposure time: 1,2 ms 1,2 ms
Max. exposure time: 3.5 s 5.0 s
Length of power cable: 6 m automatic retractable cord 6 m automatic retractable cord
Exposure release: Detachable remote control Detachable remote control
with 5 m (16.4 ft) coiled cord with 5 m (16.4 ft) coiled cord

Weight: Approx. 210 kg/462 lbs Approx. 285 kg/627 lbs


Dimensions:
Footprint (l x w x h): 104 x 56.4 x 157 cm (41 x 22 x 61.8 inch) 104 x 56.4 x 157 cm (41 x 22 x 61.8 inch)
(tube in park position)
Tube positioning: Max. focal spot height 2145 mm (84.4 inch) Max. focal spot height 2145 mm (84.4 inch)
Min. focal spot height 470 mm (18.5 inch) Min. focal spot height 470 mm (18.5 inch)
Max. horizontal ext. 1280 mm (50.4 inch) Max. horizontal ext. 1280 mm (50.4 inch)
Min. horizontal ext. 316 mm (12.4 inch) Min. horizontal ext. 316 mm (12.4 inch)

Enclosure protection type: IP 20 acc. to IEC 529 IP 20 acc. to IEC 529


Protection against Class I, Type B, acc. to IEC 601-1 Class I, Type B, acc. to IEC 601-1
electrical shock:

9
Operators Panel Sturdy hook for lead apron

Technical Data

Tube housing MOBILETT XP and MOBILETT XP Hybrid


Stabilization: Microprocessor-based adjustment and regulation during exposure
X-ray tube: Siemens P135/30 R with nominal focal spot value 0.8 (acc. to IEC 336)
Anode rotation: 8,500 r.p.m., 142 Hz (anode angle 15°)
Anode heat storage capacity: 90,000 J = 122,000 HU
Tube housing capacity: 800,000 J = 1,100,000 HU
Inherent filtration
• Collimator: min. 1.6 mm Al (at 70 kVp)
• Tube housing assembly: min. 1.5 mm Al (at 70 kVp)
• Totally: min. 3.1 mm Al according to IEC 522/1976
Collimator: Manually-adjustable multi-leaf collimator, rotatable ±90°
Collimator light and light field intensity: Halogen lamp min. 180 lux at 1 m SID
Tube housing assembly: Maximum temperature 60°C, maximum 2000 mAs/h, nominal continuous
rating 75 W until the covers reach 60°C

Leakage technique factors1: 133 kVp/10 mAs, 200 exposures/h


1 Theleakage radiation of the tube housing assembly and attached collimator complies to the requirement of
21 CFR part 1020.3 (K) and IEC601-1-3.

Motordrive MOBILETT XP Hybrid only


Drive speed: Low/high, adjustable 0.5 – 1.35 m/s
Max. incline: 7°

Batteries MOBILETT XP Hybrid only


Batteries: 20,000 mAs usable battery power storage. Automatic battery charging with
charge indicator. Mains operation with reduced output.
24 sealed maintenance-free lead batteries, Yuasa: NP 7-12L

Charging time: 12 h when completely discharged

7
Proven Outcomes. This is
what Siemens is helping
to deliver right now. Outcomes TechSwitch,
Remote switch
that result from truly efficient (optional) DAP Display
workflow. Outcomes that improve
your bottom line. Outcomes that
lead to a level of care that feels
exceptional to the patient and the
care provider. Proof positive of
the value of integrating medical
technology, IT, management
consulting and services. In a way
that only Siemens can.

Remote control (optional) MOBILETT XP and MOBILETT XP Hybrid


Compatibility: Compatible with all TechSwitch remote exposure switch systems
Technology: Infrared light beam, line-of-sight operation, will operate through glass and lead
glass; will not operate through doors or walls

Power supply of the remote control: 9-volt alkaline battery included; 25,000+ exposures; Low Battery Indicator
illuminates when battery needs to be replaced

Signature Recognition by Remote Sensor: Proprietary coding. No other known infrared remote system will activate
Operating Distance: Up to 36+ feet (10.9 m)
Operating Radius: 180°; Remote Sensor built into the front arm of X-ray unit
Remote control kit includes: Two remote controls (one spare), IR sensor with modular cable, PCB
electronics package with flat cable

DAP-equipment (optional) MOBILETT XP and MOBILETT XP Hybrid


Technology: Ionization chamber, Display and control panel
Active area: 146 x 146 mm
Operating temperature: 15 – 40°C
Weight: 0.24 kg
Typical filtration: < 0.4 mm Al equivalent
Warm-up time: Ready for use 10 seconds after power on. Specified accuracy achieved
15 minutes after power on

Chamber light transmission: ≥ 70%


Energy dependence: 50 – 150 kV ±8%, related to 100 kV (IEC60580)
40 – 50 kV ±3%, related to 50 kV

Reproducibility: > 99% under constant pressure and temperature


DAP resolution: 0.1 µGym2
Maximal measurable DAP: 1 x 106 µGym2
Dose rate linearity: < 2% deviation

Environment Operation Transport/Storage


Permissible ambient temperature: +10°C ... +40°C -20°C ... +55°C
Permissible relative humidity: 30% ... 75% 10% ... 100%1
1maximum 15 weeks

8
On account of certain regional limitations of sales rights
and service availability, we cannot guarantee that all
products included in this brochure are available through
the Siemens sales organization worldwide. Availability
and packaging may vary by country and is subject to
change without prior notice. Some/All of the features
and products described herein may not be available in
the United States.

The information in this document contains general


technical descriptions of specifications and options as
well as standard and optional features which do not
always have to be present in individual cases.

Siemens reserves the right to modify the design,


packaging, specifications and options described herein
without prior notice. Please contact your local Siemens
sales representative for the most current information.

Note: Any technical data contained in this document


may vary within defined tolerances. Original images
always lose a certain amount of detail when reproduced.

Please find fitting accessories:


www.siemens.com/medical-accessories

Siemens AG, Medical Solutions


Henkestr. 127, D-91052 Erlangen
© 2004 Siemens Medical Solutions
Germany
Order No. A91100-M1380-C601-1-7600
Telephone: +49 9131 84-0 Printed in Germany
www.siemens.com/medical GP 65601 WS 12033.