Você está na página 1de 4

Proposed Project Page:

Address of Project Project No.: 15-0001


Architect Designed: b
Post Column PC09
TIMBER CIRCULAR COLUMN V5.01 Demo User

Column: (Post Column PC09) 300mm diameter F7 seasoned softwood


Comp: Nc(dl)* = 89.1kN < øNc(dl) = 172.2kN, Nc* = 120.0kN < øNc = 241.7kN OK (0.52,0.50)
Ncw* = 76.0kN < øNcw = 302.2kN OK (0.25)
Tension: Nt(dl)* = 0.0kN < øNt(dl) = 117.4kN, Nt* = 0.0kN < øNt = 164.7kN

Combined: Refer table below No Good (1.85)

Geometry (For a primary building member)

Category = 2 (1) House, (2) Primary building elements, (3) Important


Length (L) = 3600 mm
Effective length (La) = 3600 mm Grade = F7
Bending (Lab) = 3600 mm Seasoned = S (S)easoned,(U)nseasoned
Nominal diameter (dp) = 300 mm Timber type = S (H)ardwood,(S)oftwood
Loadings
Compression Tension
Dead load (Ndl) = 50.0 kN Dead load (Ndl) = kN
Live load (Nll) = 40.0 kN Live load (Nll) = kN
Wind load (Nwl*) = kN (Comp.) Wind load (Nwl*) = kN (Tension)
Bending
Duration of Load = Floor M(dl)* = 13.37 kNm
Duration (k1) = 0.80 M* = 18.00 kNm
Long term LL factor (Ψl) = 0.40 Mw* = 11.40 kNm

Nc(dl)* = 1.35*(Ndl+Ψl*Nll) = 89.1 kN Nt(dl)* = 1.35*(Ndl+Ψl*Nll) = 0.0 kN


Nc* = 1.2*Ndl+1.5*Nll = 120.0 kN Nt* = 1.2*Ndl+1.5Nll = 0.0 kN
Ncw* = 1.2*Ndl + Nwl + Ψl*Nll = 76.0 kN Ntw* = 1.2*Ndl + Nwl + Ψl*Nll = 0.0 kN

Axial Capacity - Cl 6.3.3

Member = 300mm diameter Area (Ac) = 70686 mm²


Description = F7 seasoned softwood Section modulus (Z) = π*dp³/32 = 2651 x10³ mm³
Stiffness (I) = π*dp⁴/64 = 397.6 x10⁶ mm⁴
Modulus of elasticity (E) = 7900 MPa - Table H2.1
Strength reduction factor (ø) = 0.7 Table 2.1
S = 1.15*L/dp = 13.80 k12c = 0.895 for 10 < ρc*S ≤ 20 - Cl 3.3.3
f'c = 13.0 MPa
Nc(dl) = ø*(k1=0.57)*k4*k6*k9*k12*k20*k21*f'c*Ac = 172.2 kN f't = 7.9 MPa
øNc = ø*k1*k4*k6*k9*k12*k20*k21*f'c*Ac = 241.7 kN Material constant (ρc) = 0.88 (rc=0.50)
øNcw = ø*(k1=1)*k4*k6*k9*k12*k20*k21*f'c*Ac = 302.2 kN Size modifer (mod.c) = 1.00 Table H2.1
øNt(dl) = ø*(k1=0.57)*k4*k6*k20*k21*f't*Ac = 117.4 kN Size modifer (mod.t) = 0.89 Table H2.1
øNt = ø*k1*k4*k6*k20*k21*f't*Ac = 164.7 kN
øNtw = ø*(k1=1)*k4*k6*k20*k21*f't*Ac = 205.9 kN
Bending and Shear Capacity - Cl 6.3.1 & Cl 6.3.2

Stability factor (k12) = 1.00 (1 for round timbers) f'b = 18.0 MPa
f's = 1.9 MPa
) = ø*(k1=0.57)*k4*k6*k9*k12*k20*k21*k22*f'b*Zx = 9.99 kNm Material constant (ρb) = 0.85 (rb=0.34)
øM = ø*k1*k4*k6*k9*k12*k20*k21*k22*f'b*Zx = 14.03 kNm Duration factor (k1) = 0.80
Mw = ø*(k1=1)*k4*k6*k9*k12*k20*k21*k22*f'b*Zx = 17.53 kNm Moisture factor (k4) = 1.00
Temp. factor (k6) = 1.00
Shear plane (As) = 3*π*dp²/16 = 53014 mm² Sharing factor (k9) = 1.00
øV(dl) = ø*(k1=0.57)*k4*k6*k20*f's*As = 28.13 kN Immaturity factor (k20) = 0.70 Tab 6.2(A)
øV = ø*k1*k4*k6*k20*f's*As = 39.49 kN Shaving factor (k21) = 0.75 Tab 6.3
øVw = ø*(k1=1)*k4*k6*k20*f's*As = 49.36 kN Steamed = N (Y)es,(N)o
Processing factor (k22) = 1.00
Size modifier Bending (mod.b) = 1.00 Table H2.1
Combined - Cl 3.5.1 & Cl 3.5.2

Comp/Bend Nc(dl)* Nc* Nc(dl+wl)* Tension/Bend Nt(dl)* Nt* Nt(dl+wl)*


In/Out-plane 1.85 1.78 0.90 In/Out-plane 1.34 1.28 0.65

Deflection limits

Service class = N (1),(2),(3),(S)evere/Adverse,(N)ot applicable


Notes:

Importance:
Category 1 House failure affecting < 25m², secondary building element
Category 2 Building, house failure affecting > 25m²
Category 3 Important

Duration:
Storage and passage durations used
are based on intermediate durations from Table 2.3
and used with engineering judgement.

k4 factor:
Partial seasoning factor k4 taken as 1.
Refer Cl 2.4.2.2 & 2.4.2.3 for more information.

k6 factor:
Refer Cl 2.4.3 if designing structures near coastal
regions of Queensland north of 25°S and all other
regions north of 16°S

k20 factor:
Table 6.2(A) and 6.2(B) shows factors for the affect
of immaturity for softwood and Eucalypt and corymbia species
only. A value of 0.70 appears conservative.

k21 factor:
Table 6.3 shows factors for the affect of shaving
for softwood and Eucalypt and corymbia species only.
A value of 0.75 appears conservative.

Material constant:
Refer to Appendix E2
Bending ratio = 0.34
Compression ratio = 0.50

Compression/Bending:
Refer 3.5(1) & 3.5(2)

Tension/Bending:
Refer 3.5(3) & 3.5(4)

Service class:
Service class defined in AS/NZS 1328.1 1998 Glued Laminated Structural Timber
1 - Domestic houses, Commerical Offices
2 - Open sheds, exposed beams under soffits, porches, laundries
3 - Marine structures, Bridges
S - Severe/Adverse requires specialist advice