Select for Durability and Aesthetics: The 641 offers panel finishes for the ultimate in
design flexibility. Even the frames may be color matched to coordinate with the faces.
The 641 is a popular choice for hotel meeting rooms, convention centers, commercial
facilities, or other high use facilities.
Standard Features: The panels are nominally 4” [102] thick, and have a 16 ga. steel
frame. The top and bottom horizontal sound seals are retractable and provide floor
clearance (to accommodate out-of-level floors). The faces may be covered from a wide
selection of vinyl colors and patterns.
Individual, Omni-Directional Panels: Individual, manually operated panels offer
optimum room flexibility. The track system enables panels to negotiate turns and be
used in alternate locations.
How to Obtain: Hufcor partitions are sold, installed, and serviced by factory-trained
Top Supported local authorized Distributors in the United States and by Licensees and Distributors
Side Stack outside the U.S.A.
Individual, Omni-Directional Panels Delivery: Panels are custom built for your specific project. Lead times vary due to
Manually Operated seasonal fluctuations. Check with your Distributor for the current schedule.
Maximum Height: 40’5” [12.3m] *
Maximum Opening Width: Unlimited Warranty: Track and panels are guaranteed for two years against defects in material
STC Ratings: 43, 47, 49, 52, 54, 55, 56 and workmanship.
Optional track systems, seals, and accessories enable the standard product to be
modified for optimum versatility. See details provided or ask your Hufcor
representative for the features you want.
(3) Wood veneer (factory installed on trimmed models) 3. Seal activation requires approximately a 190 degree turn of the
(4) High pressure laminate (factory installed on trimmed models) removable handle.
2. Exposed metal trim and seal color shall be (select from Hufcor’s Optional 4” [101] bottom seals: Seal activation requires a lift/drop
Standard Trim selector): motion of the removable handle.
a. Lamb’s Wool (standard) C. Final partition closure to be by lever closure panel with expanding jamb
b. Brown (standard) which compensates for minor wall irregularities and provides a minimum
c. Gray (standard) of 250 lbs. [113.4 kg] seal force against the adjacent wall for optimum
d. Custom powder coated (optional upgrade for metal trim) sound control. The jamb activator shall be located approximately 45”
3. Aluminum track shall be clear anodized [1143] from the floor in the panel face and be accessed from either side
a. Optional upgrade: of the panel. The jamb is equipped with a mechanical rack and pinion
(1) Custom anodized gear drive mechanism and shall extend 4”-6” [101-152] by turning the
(2) Custom powder coated removable operating handle.
E. Available Accessories/Options D. Stack/Store Panels
1. ADA compliant pass door of the same thickness and construction as 1. Retract seals with removable operating handle and move to storage
the basic panels. Pass door panel legs require bottom seals that area.
provide downward force to maintain stability during door operation. 2.04 ACOUSTICAL PERFORMANCE
Pass door leaf has perimeter trim to protect face finish and to provide A. Acoustical performance shall be tested at a laboratory accredited by the
visual identification as required by International Building Code. Pass the National Voluntary Laboratory Accreditation Program (NVLAP) and in
door leaf incorporates a self-adjusting retractable bottom seal accordance with ASTM E90 Test Standards. Standard panel
providing sound control when door is closed. construction shall have obtained an STC rating of ____ (select as
a. Automatic door closer required): 43, 47, 49, 52, 54, 55, 56
b. Door lock (Not all substrates are available in all STC ratings)
c. Exit sign (consult your local code) 1. Complete, unaltered written test report is to be made available upon
d. Prepped for window request.
e. Peep hole PART 3 - EXECUTION
2. Markerboards, inset or full height A. Installation. The complete installation of the operable wall system shall
3. Inset tackboards be by an authorized factory-trained installer and be in strict accordance
4. Inset eraser pocket with the approved shop drawings and manufacturer’s standard printed
5. Segmented faces specifications, instructions, and recommendations.
6. Finished end cover B. Cleaning
7. Pocket doors 1. All track and panel surfaces shall be wiped clean and free of
8. Inset chair rail pan (for field installation of chair rail). handprints, grease, and soil.
9. Custom design options (consult your local Hufcor Distributor) 2. Cartoning and other installation debris shall be removed to onsite
10. Field sound test waste collection area, provided by others.
C. Training
2.03 OPERATION 1. Installer shall demonstrate proper operation and maintenance
A. Panels shall be manually moved from the storage area, positioned in procedures to owner’s representative.
the opening, and seals set. 2. Operating handle and owners manuals shall be provided to owner’s
B. Retractable Horizontal Seals representative.
1. Retractable horizontal seals shall be activated by a removable quick-
set operating handle located approximately 42” [1067] from the floor
in the panel edge.
2. Top and bottom retractable seals shall be operated simultaneously.
2 1/4"
Header shown for plenum [57] SOUND ATTENUATION BY OTHERS
sound enclosure is one of 1/2" [13] (MIN.) GYPSUM BOARD ON
several that may be used. CONTINUOUS METAL STUDS BY OTHERS
8" [203] MIN.
4" [102]
4" [102]
3 1/2" [89]
TOP OF SLAB
FLOOR
COVERING
THICKNESS
4" ± 7/8"
[102] ± [22]
No Scale
3a
1. Expanding Jamb Closure (Lever Closure) Panel. a. Markerboard surfaces (from Hufcor standard colors)
Expanding jamb exerts 250 lbs. [113.4kg] force against b. Tackboards of 2mm cork board covered with vinyl
adjacent wall for optimum sound control. (from Hufcor standard color selector).
2. Basic panel c.. Marker tray (standard on inset markerboards).
3. ADA compliant pass doors - Single 3/0 x 7/0 [914 x d. Full height markerboard
2132] or 3/0 x 6/8 [914 x 2030]. Of the same
construction, thickness, and finish as the basic panels. 6. Recessed Eraser Pocket (8” x 2” x 1-1/4” deep
Push/pull latching handle. Options include key lock, [203 x 50 x 31]).
windows, and automatic door closer. No threshold is 7. Lead panel with bulb seal to prevent sound leaks at
required. adjacent wall.
3a. Double (batwing) pass doors also available. Optional: Lead panel closure to 4” [101] adjustable, full
4. Exit Sign - Recessed or surface mounted, self- height, acoustic wall jamb assembly.
illuminated.
5. Work Surfaces 4’0” [1219] high x panel width,
recessed, mounted approx. 30” [762] above the floor:
Stack Dimensions
The following stack depth and width dimensions are based on a flat stack and standard construction with
vinyl faces. Optional construction and/or face covering may increase stack depth dimensions. Angled stacks
require additional space. Contact your Hufcor Distributor for angled stack requirements.
The Type 1 stack shown above is the most often used for simple omni-directional layouts. Following are additional common
stack configurations. Stacks are not limited to these configurations and may be built to fit each job requirement. Consult your
Hufcor representative for design assistance.
TYPE 2
Parallel
* TYPE 3
Double Parallel
TYPE 4
Chamfered
*
Curve/Divert Systems
*
*
* CAUTION
Body space is needed to access the panels and move them into position. Be
certain to consult your Hufcor representative before constructing walls in
pocket/stack areas. This is important for all configurations, but can be
especially important for those stacks marked with an asterisk.
1" [25]
Optional
HANGING WEIGHT continuous contact
top seals.
STC Lbs./Sq. Ft. Kg./Sq. M
43 7.8 37.8
47 8.0 38.7
49 8.5 41.2 Optional finished end cover -
provides finished panel end when
52 9.5 46.0 partition run does not extend from
54 10.9 53.2 Optional continuous wall-to-wall.
contact (sweep)
55 12.8 62.5 bottom seals. (Not 3 1/2" [89]
56 13.6 66.4 available with
optional 4” bottom 4" [102]
seal.)
2" [50]
OPTIONAL TRACKS - Alternate Hufcor track systems may be used providing the height and weight limits are within manufacturer’s guidelines.
5 1/4" [133]
2 1/4"
[57]
HUFCOR HUFCOR
514" [133]
World headquarters:
Hufcor Inc.
P.O. Box 5591
The manufacturer reserves the
2101 Kennedy Rd.
right to improve and change
Janesville, WI USA 53547-0591
product without notice.
1-800-542-2371 ext. 214; 1-608-756-1241
FAX: 1-608-758-8253
E-mail: info@hufcor.com
Website: www.hufcor.com