PRODUCT OVERVIEW:

Select for Durability and Aesthetics: The 641 offers panel finishes for the ultimate in
design flexibility. Even the frames may be color matched to coordinate with the faces.
The 641 is a popular choice for hotel meeting rooms, convention centers, commercial
facilities, or other high use facilities.
Standard Features: The panels are nominally 4” [102] thick, and have a 16 ga. steel
frame. The top and bottom horizontal sound seals are retractable and provide floor
clearance (to accommodate out-of-level floors). The faces may be covered from a wide
selection of vinyl colors and patterns.
Individual, Omni-Directional Panels: Individual, manually operated panels offer
optimum room flexibility. The track system enables panels to negotiate turns and be
used in alternate locations.
How to Obtain: Hufcor partitions are sold, installed, and serviced by factory-trained
Top Supported local authorized Distributors in the United States and by Licensees and Distributors
Side Stack outside the U.S.A.
Individual, Omni-Directional Panels Delivery: Panels are custom built for your specific project. Lead times vary due to
Manually Operated seasonal fluctuations. Check with your Distributor for the current schedule.
Maximum Height: 40’5” [12.3m] *
Maximum Opening Width: Unlimited Warranty: Track and panels are guaranteed for two years against defects in material
STC Ratings: 43, 47, 49, 52, 54, 55, 56 and workmanship.

*Taller heights are available. Contact


your Hufcor Distributor for assistance.

"Standard" Product Features and Benefits:


Look for these features when comparing similar products.
1. Feature: Protective vertical trim (Available option: no 5. Feature: Waist high seal activator for quick set retractable
protective vertical face trim.) seals.
Benefit: Trim protects the panel edges and faces plus it Benefit: Fast, easy seal activation without bending or
provides a handhold when moving panels. stooping.
2. Feature: Quick-Set™ Retractable Seals 6. Feature: Removable operating handle.
. Benefit: The retractable seals are Quick-Set™ which Benefit: Prevents unauthorized operation.
means they are easily extended or retracted with only 7. Feature: Expanding Jamb Closure (Lever Closure) Panel
a 1/2 turn of the removable handle. No tedious Benefit: Exerts 250 lbs [113.4 kg] of force against the
cranking needed to set the seals. fixed wall. The compression creates tight panel joints
3. Feature: 2” [51] retractable bottom seals for optimum sound control.
Benefit: Retractable seals accommodate out-of-level 8. Feature: Interlocking vertical seals
floor conditions. When retracted, nothing drags on Benefit: Ensures panel-to-panel alignment and prevents
the floor when the panels are moved. Panels can be sound leaks between panels.
“locked” in place.
4. Feature: Retractable seals exert upward and downward
seal force
Benefit: Provides constant force against the track and
floor for optimum acoustics even on carpet or other
porous floor materials. Maintains panel stability when
the seals are set.

Optional track systems, seals, and accessories enable the standard product to be
modified for optimum versatility. See details provided or ask your Hufcor
representative for the features you want.

Figures in brackets [ ] are in millimeters unless otherwise noted. 1


F4147I
GENERAL SPECIFICATIONS/SERIES 641
Individual, Omni-Directional Partitions 4. Vertical sound seals shall be of tongue and groove configuration, ensure
panel-to-panel alignment and prevent sound leaks between panels.
PART 1 - GENERAL 5. Horizontal top seals shall be retractable, provide 1” [25] nominal operating
1.01 DESCRIPTION clearance, and exert upward force when extended. All panels, including
A. General pass door panels and lever closure panels must have retractable top and
1. Furnish and install operable partitions and suspension system. Provide bottom seals.
all labor, materials, tools, equipment, and services for operable walls in Optional: Horizontal top seals shall be fixed continuous contact dual 4-
accordance with provisions of contract documents. finger vinyl.
6. Horizontal bottom seals shall be retractable, provide up to 2” [51] nominal
1.02 RELATED WORK BY OTHERS
operating clearance, and exert downward force when fully extended.
A. Preparation of opening will be by General Contractor. Any deviation of site
Optional:
conditions contrary to approved shop drawings must be called to the
a. Horizontal bottom seals shall be retractable, provide 4” [101] nominal
attention of the architect.
operating clearance, and exert 97 lbs. [44 kg] downward force when
B. All header, blocking, support structures, jambs, track enclosures,
fully extended.
surrounding insulation, and sound baffles as required in 1.04 Quality
b. Horizontal bottom seals shall be fixed continuous contact 4-finger vinyl.
Assurance.
7. Horizontal trim shall be of aluminum.
C. Prepunching of support structure in accordance with approved shop
B. Weight of the panels shall be 7.8-13.6 lbs./sq. ft. [37.8-66.4 kg/sq.m] based
drawings.
on options selected.
D. Paint or otherwise finishing all trim and other materials adjoining head and
C. Suspension system:
jamb of operable partitions.
1. For panels to 1000 lbs. [455 kg] or 22’2” [6.75m]: Track shall be of clear
1.03 SUBMITTALS anodized architectural grade extruded aluminum alloy 6063-T6. Track
A. Complete shop drawings are to be provided prior to fabrication indicating design shall provide precise alignment at the trolley running surfaces and
construction and installation details. Shop drawings must be submitted provide integral support for adjoining ceiling, soffit, or plenum sound
within 60 days after receipt of signed contract. barrier. Track shall be connected to the structural support by pairs of
minimum 3/8” [10] dia. threaded steel hanger rods. Pairs of rods are
1.04 QUALITY ASSURANCE directly attached to the track, no single point attachment allowed. L, T, or
A. Preparation of the opening shall conform to the criteria set forth per ASTM X intersections shall be factory assembled and welded.
E557 Standard Practice for Architectural Application and Installation of a. Each panel shall be supported by two 2-wheeled counter-rotating
Operable Partitions horizontal carriers. Wheels to be of precision ground steel ball
B. The partition STC (Sound Transmission Classification) shall be achieved bearings with heat treated and hardened races encased with molded
per the standard test methods ASTM E90. polymer tires.
C. Noise isolation classifications shall be achieved per the standard test 2. For panels 1000-1500.lbs. [455-680 kg]: Track shall be of clear anodized
methods ASTM E336 and ASTM E413. architectural grade extruded aluminum alloy 6063-T6. Track design shall
D. Noise Reduction Coefficient (NRC) ratings shall be per ASTM C423. provide precise alignment at the trolley running surfaces and provide
E. Rack testing for 10 years. (tensional strength stress test) integral support for adjoining ceiling, soffit, or plenum sound barrier. .
F. The manufacturer shall have a quality system that is registered to the ISO Track shall be connected to the structural support by pairs of minimum
9001 standards. 1/2” [13] dia. threaded steel hanger rods. Pairs of rods are directly
attached to the track, no single point attachment allowed. L, T, or X
1.05 PRODUCT DELIVERY, STORAGE, AND HANDLING
intersections shall be factory assembled and welded.
A. Proper storage of partitions before installation and continued protection
a. Each panel shall be supported by two 2-wheeled counter-rotating
during and after installation will be the responsibility of the General
horizontal carriers. Wheels to be of precision ground steel ball
Contractor.
bearings with heat treated and hardened races encased with molded
1.06 WARRANTY polymer tires, steel banded and reinforced.
A. Partition system shall be guaranteed for a period of two years against 3. For panels 1500-3000 lbs. [680-1364 kg]: Track shall be of 1/4” [6]
defects in material and workmanship, excluding abuse. formed black painted steel connected to the structural support by pairs of
minimum 1/2” [13] threaded steel hanger rods. Track trim shall be clear
PART 2 - PRODUCTS anodized aluminum. Carriers to have four steel wheels with precision
2.01 ACCEPTABLE MANUFACTURERS ground radial bearings. Bearings are inserted into a steel tire. The steel
A. Upon compliance with all of the criteria specified in this section, tire rim fully captures the bearing. Carriers may be programmed for self-
Manufacturers wishing to bid products equal to the product specified must directing and sorting.
submit to the architect 10 days prior to bidding complete data in support of 4. Optional tracks may be used providing the height and weight limits are
compliance and a list of three past installations of products similar to those within manufacturers guidelines. See page 6 “Optional Tracks”.
listed. The submitting manufacturer guarantees the proposed substituted 5. Option (available for select layouts-consult your Hufcor Distributor): The
product complies with the performance items specified and as detailed on panels shall be supported by the Unispan pre-engineered truss and post
the drawings. system fabricated of steel and aluminum. Unispan is attached to the
building structure for lateral support only. The load of the truss and
2.02 MATERIALS partition is supported by end columns. The columns are connected to
A. Product to be top supported Series 641 individual, omni-directional panels floor plates that distribute the load of the system at the floor.
as manufactured by Hufcor Inc. 6. Plenum closure (by others): Design of plenum closure must permit lifting
1. Panels shall be nominally 4” [101] thick and to 48” [1219] in width. out of header panels to adjust track height. Plenum closure required for
2. Panel faces shall be laminated to appropriate substrate to meet the STC optimum sound control of partition.
requirement in 2.04 Acoustical Performance. D. Finishes
a. Optional substrate material (Not all substrates are available for all 1. Face finish shall be: (select as required):
STC ratings. Consult your Hufcor Distributor for more information): a. Factory applied reinforced vinyl fabric with woven backing, weighing not
Steel less than 20 oz. per lineal yard [620 g/m]. Color shall be selected from
Non-steel manufacturer’s standard color selectors.
b. Horizontal Splice: Heights over 16'3" [4953] with non-steel faces b. Standard upgrade fabrics (color shall be selected from manufacturer’s
require a structural splice placed at approximately 12’3” [3734] from standard color selector):
the floor. (1) Factory applied vertical ribbed carpet (N.R.C. .20)
3. Frames shall be of 16 gauge [1.42mm] steel with integral factory applied (2) Factory applied stain resistant fabric
aluminum vertical edge and face protection. c. Optional:
Optional: Face finish shall wrap around the vertical panel edges and (1) Customer selected (requires factory approval for manufacturing
provide no protective vertical face trim. compatibility)
(2) Unfinished for field decoration

2 Figures in brackets [ ] are in millimeters unless otherwise noted


SERIES 641

(3) Wood veneer (factory installed on trimmed models) 3. Seal activation requires approximately a 190 degree turn of the
(4) High pressure laminate (factory installed on trimmed models) removable handle.
2. Exposed metal trim and seal color shall be (select from Hufcor’s Optional 4” [101] bottom seals: Seal activation requires a lift/drop
Standard Trim selector): motion of the removable handle.
a. Lamb’s Wool (standard) C. Final partition closure to be by lever closure panel with expanding jamb
b. Brown (standard) which compensates for minor wall irregularities and provides a minimum
c. Gray (standard) of 250 lbs. [113.4 kg] seal force against the adjacent wall for optimum
d. Custom powder coated (optional upgrade for metal trim) sound control. The jamb activator shall be located approximately 45”
3. Aluminum track shall be clear anodized [1143] from the floor in the panel face and be accessed from either side
a. Optional upgrade: of the panel. The jamb is equipped with a mechanical rack and pinion
(1) Custom anodized gear drive mechanism and shall extend 4”-6” [101-152] by turning the
(2) Custom powder coated removable operating handle.
E. Available Accessories/Options D. Stack/Store Panels
1. ADA compliant pass door of the same thickness and construction as 1. Retract seals with removable operating handle and move to storage
the basic panels. Pass door panel legs require bottom seals that area.
provide downward force to maintain stability during door operation. 2.04 ACOUSTICAL PERFORMANCE
Pass door leaf has perimeter trim to protect face finish and to provide A. Acoustical performance shall be tested at a laboratory accredited by the
visual identification as required by International Building Code. Pass the National Voluntary Laboratory Accreditation Program (NVLAP) and in
door leaf incorporates a self-adjusting retractable bottom seal accordance with ASTM E90 Test Standards. Standard panel
providing sound control when door is closed. construction shall have obtained an STC rating of ____ (select as
a. Automatic door closer required): 43, 47, 49, 52, 54, 55, 56
b. Door lock (Not all substrates are available in all STC ratings)
c. Exit sign (consult your local code) 1. Complete, unaltered written test report is to be made available upon
d. Prepped for window request.
e. Peep hole PART 3 - EXECUTION
2. Markerboards, inset or full height A. Installation. The complete installation of the operable wall system shall
3. Inset tackboards be by an authorized factory-trained installer and be in strict accordance
4. Inset eraser pocket with the approved shop drawings and manufacturer’s standard printed
5. Segmented faces specifications, instructions, and recommendations.
6. Finished end cover B. Cleaning
7. Pocket doors 1. All track and panel surfaces shall be wiped clean and free of
8. Inset chair rail pan (for field installation of chair rail). handprints, grease, and soil.
9. Custom design options (consult your local Hufcor Distributor) 2. Cartoning and other installation debris shall be removed to onsite
10. Field sound test waste collection area, provided by others.
C. Training
2.03 OPERATION 1. Installer shall demonstrate proper operation and maintenance
A. Panels shall be manually moved from the storage area, positioned in procedures to owner’s representative.
the opening, and seals set. 2. Operating handle and owners manuals shall be provided to owner’s
B. Retractable Horizontal Seals representative.
1. Retractable horizontal seals shall be activated by a removable quick-
set operating handle located approximately 42” [1067] from the floor
in the panel edge.
2. Top and bottom retractable seals shall be operated simultaneously.

2 1/4"
Header shown for plenum [57] SOUND ATTENUATION BY OTHERS
sound enclosure is one of 1/2" [13] (MIN.) GYPSUM BOARD ON
several that may be used. CONTINUOUS METAL STUDS BY OTHERS
8" [203] MIN.

See ASTM E557 Standard


Practice for Archl 3/8" [10] Ø HANGER RODS
Application & Installation of
Operable Partitions for CEILING BY OTHERS
other recommendations. 3 1/2" [89] HUFCOR

5" [127] HUFCOR

Shown with Type 36 1" [25]


1" [25]
Aluminum track.
Standard for weights to
1000 lbs. [455 kg].
Alternate track systems
may be used providing
the height and weight
3 1/2" [89]
limits are within
manufacturers guidelines.
UNIT HEIGHT

4" [102]

4" [102]

3 1/2" [89]

4" [102] Optional Bottom Seal:


4” clearance
2" [50]
TOP OF FIN. FLOOR

TOP OF SLAB
FLOOR
COVERING
THICKNESS

VERTICAL SECTION No Scale

Figures in brackets [ ] are in millimeters unless otherwise noted. 3


DETAILS SERIES 641

Individual, Omni-Directional Operable Partitions


HORIZONTAL SECTION shown with standard vertical trim.
Final partition closure using expanding closure panel. Solid blocking required at both ends to withstand 250 lbs. [113.4 kg] of lateral force.

6" [152] 1" [25]

LEVER CLOSURE PANEL JOINT BULB SEAL


( EXPANDING JAMB )

4" ± 7/8"
[102] ± [22]

Optional: No Option: Wall Jamb


vertical face trim Assembly
panel joint.

No Scale

OPTIONS & ACCESSORIES ELEVATION

3a

1. Expanding Jamb Closure (Lever Closure) Panel. a. Markerboard surfaces (from Hufcor standard colors)
Expanding jamb exerts 250 lbs. [113.4kg] force against b. Tackboards of 2mm cork board covered with vinyl
adjacent wall for optimum sound control. (from Hufcor standard color selector).
2. Basic panel c.. Marker tray (standard on inset markerboards).
3. ADA compliant pass doors - Single 3/0 x 7/0 [914 x d. Full height markerboard
2132] or 3/0 x 6/8 [914 x 2030]. Of the same
construction, thickness, and finish as the basic panels. 6. Recessed Eraser Pocket (8” x 2” x 1-1/4” deep
Push/pull latching handle. Options include key lock, [203 x 50 x 31]).
windows, and automatic door closer. No threshold is 7. Lead panel with bulb seal to prevent sound leaks at
required. adjacent wall.
3a. Double (batwing) pass doors also available. Optional: Lead panel closure to 4” [101] adjustable, full
4. Exit Sign - Recessed or surface mounted, self- height, acoustic wall jamb assembly.
illuminated.
5. Work Surfaces 4’0” [1219] high x panel width,
recessed, mounted approx. 30” [762] above the floor:

Figures in brackets [ ] are in millimeters unless otherwise noted. 4


LAYOUT OPTIONS SERIES 641

Individual, Omni-Directional Operable Partitions

Stack Dimensions
The following stack depth and width dimensions are based on a flat stack and standard construction with
vinyl faces. Optional construction and/or face covering may increase stack depth dimensions. Angled stacks
require additional space. Contact your Hufcor Distributor for angled stack requirements.

Stack Depth: 4-1/4” [108] per panel plus 1" [25]


Optional panic hardware will add to the depth of the stack.
Please contact your Hufcor distributor for assistance.
Stack Width: Panel width + 12" [300] clearance.
For Pocket Storage: Due to the wide variety of stack
configurations possible, consult your Hufcor representative
for space requirements.
TYPE 1
Side Stack

The Type 1 stack shown above is the most often used for simple omni-directional layouts. Following are additional common
stack configurations. Stacks are not limited to these configurations and may be built to fit each job requirement. Consult your
Hufcor representative for design assistance.

TYPE 2
Parallel
* TYPE 3
Double Parallel
TYPE 4
Chamfered
*
Curve/Divert Systems

Curves, diverters, switches


for easy movement of very
tall/heavy panels. The
carriers may be
programmed for self-
directing and sorting.

*
*
* CAUTION
Body space is needed to access the panels and move them into position. Be
certain to consult your Hufcor representative before constructing walls in
pocket/stack areas. This is important for all configurations, but can be
especially important for those stacks marked with an asterisk.

5 Figures in brackets [ ] are in millimeters unless otherwise noted


OPTIONS - NOT TO SCALE SERIES 641

1" [25]

Optional
HANGING WEIGHT continuous contact
top seals.
STC Lbs./Sq. Ft. Kg./Sq. M
43 7.8 37.8
47 8.0 38.7
49 8.5 41.2 Optional finished end cover -
provides finished panel end when
52 9.5 46.0 partition run does not extend from
54 10.9 53.2 Optional continuous wall-to-wall.
contact (sweep)
55 12.8 62.5 bottom seals. (Not 3 1/2" [89]
56 13.6 66.4 available with
optional 4” bottom 4" [102]
seal.)
2" [50]

OPTIONAL TRACKS - Alternate Hufcor track systems may be used providing the height and weight limits are within manufacturer’s guidelines.

5 1/4" [133]
2 1/4"
[57]

3 1/2" [89] HUFCOR


3 1/2" [89] HUFCOR

HUFCOR HUFCOR

4-1/2” 4-7/8 " [124]


[114]

Type 26 Aluminum Track Type 36 Aluminum track. Type 57 Aluminum Track


Optional for panel weights to 500 lbs. Standard for weights to 1000 lbs. [455 kg]. For panel weights to 1500 lbs. [682 kg]. Each
[227 kg]. Each carrier has two horizontal Shown with optional suspension bracket wheel of the carrier has precision ground bearings,
counter-rotating wheels. Each wheel has available for 5-1/4” [133] spacing. Suspension encased with Delrin, steel banded and reinforced.
precision ground bearings, encased with bracket is available for all aluminum tracks. May be programmed for self-directing and sorting.
Delrin for quiet operation. Minimum Minimum dimension from the ceiling to the structure
dimension from the ceiling to the is 12” [305].
structure is 8” [203].

514" [133]

Type 11 Steel Track


Type 11L Steel Track For panel weights to 3000 lbs. [1364
For panel weights to 1400 kg]. Track is of 1/4” [6] formed steel.
414" [107]

lbs. [635 kg]. Track is of Track trim is clear anodized


3/16” [5] formed steel. aluminum. Curves, diverters, or
Track trim is clear anodized switches are available. Each carrier
aluminum. Each carrier has has four steel wheels with precision
four steel wheels with ground radial bearings. Bearings
precision ground radial are inserted into a steel tire. Tire rim
bearings. Minimum fully captures the bearing. Carriers
dimension from the ceiling may be programmed for self-
to the structure is 8” [203]. directing and sorting. Minimum
514" [133] dimension from the ceiling to the
structure is 12” [305].

World headquarters:
Hufcor Inc.
P.O. Box 5591
The manufacturer reserves the
2101 Kennedy Rd.
right to improve and change
Janesville, WI USA 53547-0591
product without notice.
1-800-542-2371 ext. 214; 1-608-756-1241
FAX: 1-608-758-8253
E-mail: info@hufcor.com
Website: www.hufcor.com

F-4147I Figures in brackets [ ] are in millimeters unless otherwise noted 6

Você também pode gostar